Home
SAS to SAS/SATA II JBOD Subsystem User Manual
Contents
1. 5 Turn the disk tray upside down To secure the disk drive into the disk tray tighten four screws on the holes of the disk tray Note in the picture below where the screws should be place in the disk try holes 6 Insert the disk tray into the subsystem User Manual pum SAS to SAS SATA II JBOD Subsystem 2 3 Connecting the J BOD Subsystem 2 3 1 Connecting to SAS HBA The Enclosure supports SAS interface which provides fast 300MB data transfer rate using SAS phy The package comes with one SAS cable for single J BOD controller module or two SAS cables for redundant J BOD controller modules Attach one end of the SAS cable to the SAS IN Port and the other end to the host bus adapter s HBA external SAS connector or to the SAS Switch The host bus adapter is installed in your Host computer system 2 3 2 Connecting to RAI D Subsystem Attach one end of the SAS cable to the SAS IN Port of the JBOD controller module and the other end to the SAS Expansion Port on the RAID controller of RAID subsystem If configured in redundant mode connect the other SAS cable to the SAS IN Port of the other JBOD controller and the other end to the SAS Expansion Port on the other RAID controller of RAID subsystem NP User Manual SAS to SAS SATA II JBOD Subsystem Chapter 3 Maintenance 3 1 Upgrading Firmware Upgrading Firmware Trough Terminal NOTE It is important to stop I O access to J BOD subsystem during 4 firmware upgrade
2. NOTE Upgrading the firmware must be done from Master J BOD Controller if the JBOD Subsystem has redundant J BOD Controllers 1 Please use the null modem cable RJ 11 to DB9 and to connect J BOD Monitor Port and PC COMI Port or change to other COM Port as necessary 2 Open Windows HyperTerminal Program Connect using COM1 COM Port used in Step1 Baud Rate 115200 n 8 1 Flow Control None 3 Press the Enter key and the password prompt will be displayed 4 Key in the password Default password 00000000 to login to CLI 5 AtCLI prompt input the command to update firmware a CLI gt er datl b CLI gt er code NOTE er code is the command to erase flash firmware code er dati is the command to erase CFG data code fl code is the command to update flash firmware code bin file fl dat1 is the command to update CFG data code rom file Make sure you have both files before updating CLI gt fl dati d Select Function menu to transfer CFG data rom file Function gt Transfer gt Send File gt Browse gt Open and select the rom file for example 8010 mfgdat1 090608 firmware folder location Select 1K Xmodem Protocol to send firmware file Only need about 15 seconds to finish sending firmware file If not please repeat steps C and D again e CLI fl code f Select Function menu to transfer firmware file Function 3 Transfer gt Send File gt Browse 3 Open and s
3. RPM becomes stable When Fan RPM is already stable the RAI D controller will then power on the Power Supply This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work a2 User Manual SAS to SAS SATA II JBOD Subsystem 1 6 LCD Display Panel Model Name Chassis ID 0 1 6 1 LCD Panel LED Power LED Power Fail LED Fan Fail LED Over Temperature LED Voltage Warning LED Reserved for RAID Subsystem Power LED If one of the redundant power supply unit fails this LED will turn to RED and alarm will sound Power Fail LED Turn RED when fan 1 or 2 fails or Fan Fail LED speed is lower than 500 RPM If disk temperatures exceed 60 C Over Temperature LED the Over Temperature LED will turn RED and alarm will sound An alarm will sound if detected voltage in the controller is Voltage Warning LED 9 9 abnormal and LED will turn RED User Manual Ia SAS to SAS SATA II JBOD Subsystem 1 6 2 LCD Panel Function Buttons Up and Down 4 Use the Up or Down arrow keys to go through the information on the ATOW DUHOnS bd LCD screen This is also used to move between each menu This is used to enter the option Select button you have selected Press this button to return to the EI User Manual SAS to SAS SATA II JBOD Subsystem 1 7 Drive Carrier Module The Drive Carrier Module houses a 3 5 inch hard disk drive It is
4. designed for maximum airflow and incorporates a carrier locking mechanism to prevent unauthorized access to the HDD 1 7 1 Disk Drive Status I ndicators Disk Activity 47 5 I ndicator Disk Status Indicator This LED will blink blue when the hard drive is being Disk Activity Indicator accessed Green LED indicates power is on and hard drive status is good for this slot If there is no hard drive the LED is Disk Status Indicator Red The fault indicator depends on the RAID card or RAID Controller definition User Manual 15 SAS to SAS SATA II JBOD Subsystem 1 7 Drive Carrier Module The Drive Carrier Module houses a 3 5 inch hard disk drive It is designed for maximum airflow and incorporates a carrier locking mechanism to prevent unauthorized access to the HDD 1 7 1 Disk Drive Status I ndicators Every Drive Carrier has 2 status indicator lights One indicator light is used for Power On Error Disk Status Indicator When this light is GREEN the power is on and everything is functioning normally When the Power On Error light is RED then an error has happened that requires the user s attention The other status indicator light is the hard disk drive access light Disk Activity Indicator When the hard disk drive is being accessed this light will flash BLUE In addition both indicator lights are viewable within a 170 arc Disk Activity 4C 5 Indicator A Disk Status Indicator Use
5. BOD Controller Module Power Supply Power Supply Fan Module 1 Fan Module 2 Dual BOD Controller JBOD Controller 1 JBOD Controller 2 ONINZYM gt ua ER ra i p CO F F a i a ur ux IL i Power Supply Power Supply Fan Module 1 Fan Module 2 EX User Manual SAS to SAS SATA II JBOD Subsystem 1 4 3 JBOD Controller Module The EPICa JBOD subsystem includes a single or dual 3Gb SAS to SAS SATA II J BOD Controller Module ENT DOE ANE AE a aar ieee Eaa etes m OSA LT JBOD Controller Module User Manual rmm SAS to SAS SATA II JBOD Subsystem 1 4 3 1 JBOD Controller Panel SAS Expansion Port ID a rr HAMM unn x ii d x y X 9 0 A 0 0 G0 qe LR A er dx x MORGNOM FN aO atate anne el Link LED RS 232 Port SAS In Port Activity LED Use to connect to SAS HBA or to RAID subsystem s SAS Expansion Port SAS Expansion Port Use to connect to the SAS In Port of another J BOD subsystem Use to upgrade the firmware of the BOD RS 232 Port controller Connect the RJ 11 to DB9 serial cable to your system s serial port I ndicates expander has connected or linked Activity LED Blinking Indicates the expander is busy and being Blue accessed ERI User Manual SAS to SAS SATA II JBOD Subsystem 1 5 Power Supply Fan Module PSFM The EPICa JBOD subsystem contains two 500W Power Supply Fan Modules All PSFMs are inserted into the rear o
6. Disk Tray NOTE These steps are the same when installing SATA disk drive in Single Controller Mode 1 Unlock the Disk Trays using a flat head screw driver by rotating the Lock Groove Disk Tray is unlocked Tray Open Button 3 Pull out an empty disk tray Pull the handle outwards to remove the tray from the enclosure EE User Manual SAS to SAS SATA II JBOD Subsystem 4 Place the hard drive in the disk tray Make sure the holes of the disk tray align with the holes of the hard drive 5 Install the mounting screws on the bottom part to secure the drive in the disk tray 6 Slide the tray into a slot 7 Press the lever in until you hear the latch click into place The HDD Fault LED will turn green when the subsystem is powered on and HDD is good 8 If necessary lock the Disk Tray by turning the Lock Groove User Manual ETHE SAS to SAS SATA II JBOD Subsystem 2 2 2 Installing a SATA Disk Drive Dual J BOD Mode in a Disk Tray 1 Remove an empty disk tray from the subsystem 2 Prepare the dongle board and two screws aon Beer P0 T wu tae ficte i TEE hale F wi 3 E id 3 Place the dongle board in the disk tray Turn the tray upside down Tighten two screws to secure the dongle board into the disk tray 20 User Manual SAS to SAS SATA II JBOD Subsystem 4 Place the SATA disk drive into the disk tray Slide the disk drive towards the dongle board
7. Four 4x mini SAS 3Gb s Capacity Direct Attached 16 Disks Please refer to RAID controller specification Monitor Port support Yes Rackmount of Hot Swap Trays 16 UJ Cc Tray Lock Yes Disk Status I ndicator Access Fail LED Power LED wame po O yO AC 90V 264V Full Range 10A 5A 47Hz 63Hz S90 L x 482 W x 131 H mm Weight 2a 25 Kg Without Disk User Manual ONE SAS to SAS SATA II JBOD Subsystem 1 3 Unpacking the J BOD Subsystem The shipping package contains the following JBOD Subsystem Unit Two 2 power cords One serial cable RJ11 to DB9 Note Two serial cables for dual J BOD controllers One external Mini SAS cable SFF 8088 to SFF 8088 Note Two mini SAS cables for dual JBOD controllers One 1 JBOD Module Plate Cover NOTE For Dual JBOD Controller One 1 PSFM Plate Cover User Manual NOTE If any damage is found contact the dealer or vendor for assistance EN User Manual SAS to SAS SATA II JBOD Subsystem 1 4 Identifying Parts of the J BOD Subsystem The illustrations below identify the various parts of the expansion chassis 1 4 1 Front View Smart LCD Panel Drive Carriers Slot 4 Slot 3 Slot 2 Slot 1_ 1 Slot 8 Slot 7 Slot 6 Slot 5 Slot 12 Slot 11 Slot 10 SIot 9 Slot 16 Slot 15 Slot 14 Slot 13 User Manual NE SAS to SAS SATA II JBOD Subsystem 1 4 2 Rear View Single J BOD Controller J
8. SAS and SATA drives allows the EP 3163 D S3S3 to be used for a range of applications that require different price performance characteristics Cost effective SATA drives can be selected for capacity orientated storage such as disk to disk backup and the storage of reference data Higher specification SAS drives can be employed for I O intensive applications including transactional databases Hosting multiple tiers of data in an EP 3163 JD S3S3 configuration gives organizations the flexibility to meet both their technical requirements and budgetary constraints with a single unified solution User Manual a SAS to SAS SATA II JBOD Subsystem l l Features 16 hot swappable drive bays in a rackmount 3U chassis Simultaneously support SAS or SATA disk Single or dual SAS JBOD controller module Each SAS JBOD controller module has three mini SAS 4X ports Power Supply and cooling system contained in 1 module for efficient cooling Two 500W redundant hot swappable power supplies Incorporates a cableless design for maximum signal integrity Utilizes industry standard SCSI Enclosure Services to monitor enclosure and disk environmental conditions EN User Manual SAS to SAS SATA II JBOD Subsystem 1 2 Technical Specifications EP 3163 S3S3 EP 3163 D S3S3 RAID Controller JBOD Controller Single Redundant Host I nterface One Two 4x mini SAS 3Gb s Disk I nterface SAS 3Gb or SATA II SAS expansion Two
9. SAS to SAS SATA II JBOD Subsystem User Manual SAS to SAS SATA II JBOD Subsystem Table of Contents Chapter 1 EHUOOUUCHOD uoi iiri EHIEI UE 023 DEAE Aen tne neers ee n ee ene eT 3 ME uc 4 L2 Tecnnieal SDScITICHUtIOH S esaostesit risit bap se eter E tinte aset tieu dole utu S 5 13 Unpacking tie JBOD SUDEYSTEIM einser e rien e ertet ert Ae e aE AA TEE E ET O e onera ind 6 14 Identifying Parts of the JBOD SUDSYStEM cc ccsessessssesessssesessesessesessssesessesessssessssesesccseausseseesesesseseeneseeeeseees 7 ad SON MCW c C 7 TAZ REEN W een E E E E te E AEE A 8 143 JBOD C ntroler 74 8 9 0 eee ce teen emer fo ae aE E ENEN E ete Rie eee 9 1 2 51 JBOD COntteller Pa3llblauesnastedentenensteodusode ne s E e Er tte ne Cee entre 10 L5 Power Supply Fan Module C OS mE 11 EL PORNP ONO e E E E E E A NS 11 E LCT Ey 1 P e E A E nee ry TT nome Oe 13 1531 LCP Pane EBD e E N E en eee Cee dubi eM 13 t62 LCD Panel F nction iiie RE 14 I7 Pe Caer MoO TR E E A EA 15 171 Disk Drive Status Indicators ae nee ee eee ea e EE Pere ene er 15 172 DrveCarnmer Lock Indicator m T 16 Chapter 2 Installation of J BOD Subsystem 0000000osoooooo0eeeessssoococeeeesssssssssceeee 17 AE PON Oee a E AAA 17 Z2 DISK Dive si lid 6 ERN E E Ea ee A EE SE 18 2 2 1 Installing a SAS Disk Drive in a Disk Tray cccesessessssssesscssesscsssssssscsssesessssssessssesesesssse
10. elect the bin file for example 8010 05 63 1 32 090526 bin from firmware folder User Manual 23 SAS to SAS SATA II JBOD Subsystem location Select 1K Xmodem Protocol to send firmware file Only need about 15 seconds to finish sending firmware file If not please repeat steps E and F again NOTE If the J BOD Subsystem has redundant J BOD Controllers remove the serial cable RJ 11 to DB9 from RS232 Port of J BOD Controller 1 and insert in the RS232 Port of J BOD Controller 2 and then repeat steps 3 to 6 to upgrade J BOD Controller 2 After upgrading both controllers power cycle the J BOD Subsystem Then login to CLI to verify JBOD firmware version NOTE If JBOD Subsystem has single J BOD Controller you can use the xr command to restart the J BOD Controller without needing to power cycle Re login to JBOD CLI Use sy command to verify J BOD firmware version CLI gt sy If needed the xr command can also be used to restart the J BOD controller Normally used in single JBOD Controller mode CLI gt xr EE User Manual SAS to SAS SATA II JBOD Subsystem 3 2 Replacing J BOD Subsystem Components 3 2 1 Replacing J BOD Controller Module When replacing a failed JBOD Controller Module please follow these steps Loosen the thumbscrews on the sides of the JBOD Controller Module drawer 2 Use the Controller handle to pull out the defective JBOD Controller Module drawer 3 Insert and slide the new JBOD Contr
11. f the chassis 1 5 1 PSFM Panel d l i Saa l A Power On Fail Indicator Power On Off Switch AC Power Inlet Plug Male The panel of the Power Supply Fan Module contains the Power On Off Switch the AC Inlet Plug and a Power On Fail Indicator showing the Power Status LED indicating ready or fail Each fan within a PSFM is powered independently of the power supply within the same PSFM So if the power supply of a PSFM fails the fan associated with that PSFM will continue to operate and cool the enclosure When the power cord connected from main power source is inserted to the AC Power Inlet the power status LED becomes RED When the switch of the PSFM is turned on the LED will turn GREEN When the Power On Fail LED is GREEN the PSFM is functioning normally User Manual rra SAS to SAS SATA II JBOD Subsystem NOTE Each PSFM has one Power Supply and two Fans PSFM 1 has Power 1 and Fan 1 and Fan 2 The PSFM 2 has Power 2 and Fan 3 and Fan 4 When the Power Supply of a PSFM fails the PSFM need not be removed from the slot if replacement is not yet available The fan will still work and provide necessary airflow inside the enclosure In replacing the failed PSFM refer to section 3 2 2 of this manual NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the
12. h controller disk drive temperature 7 Connect the power cord to the AC Inlet Plug of PSFM 8 Tighten the thumbscrews of the PSFM 9 Turn on the Power On Off Switch of the PSFM NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the RAI D controller will then power on the Power Supply This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work EE User Manual SAS to SAS SATA II JBOD Subsystem 3 2 2 1 Replacing Power Supply Fan Module with Plate Cover When replacing a failed power supply fan module PSFM with Plate Cover please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the failed PSFM Pull out the defective PSFM Insert the PSFM Plate Cover carefully pU de A ws MINIS e INFINITIS User Manual 27
13. oller Module in Note that it may be necessary to remove the old defective JBOD Controller Module from the drawer case and install the new one I MPORTANT When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature 4 Tighten the thumbscrews on the sides of the JBOD Controller Module case User Manual 25 SAS to SAS SATA II JBOD Subsystem 3 2 2 Replacing Power Supply Fan Module When replacing a failed power supply fan module PSFM please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the PSFM Use the handle to pull out the defective PSFM Before inserting the new PSFM make sure the Power On Off Switch is on Off state Ui AA W N HG 6 Insert and slide the new PSFM in until it clicks into place I MPORTANT When the subsystem is online and a Power Supply fails and the replacement Power Supply module is not yet available the failed Power Supply Module can be replaced with the Plate Cover This is to maintain proper airflow within the enclosure Refer to next section When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing hig
14. r Manual 15 SAS to SAS SATA II JBOD Subsystem 1 7 2 Drive Carrier Lock Indicator Every Drive Carrier is lockable and is fitted with a lock indicator to indicate whether or not the carrier is locked into the chassis or not Each carrier is also fitted with an ergonomic handle for easy carrier removal Drive Carrier is unlocked Drive Carrier is locked When the Lock Groove is horizontal this indicates that the Drive Carrier is locked Lock and unlock the Drive Carriers by using a flat head screw driver 16 User Manual SAS to SAS SATA II JBOD Subsystem Chapter 2 Installation of J BOD Subsystem 2 1 Powering On l Plug in the power cords into the AC Power Input Socket located at the rear of the subsystem Power On Off Switch AC Power Input Socket NOTE The subsystem is equipped with redundant full range power supplies with PFC power factor correction The system J will automatically select voltage 2 Turn on each Power On Off Switch to power on the subsystem 3 The Power LED on the front panel will turn green User Manual HUNE SAS to SAS SATA II JBOD Subsystem 2 2 Disk Drive I nstallation This section describes the physical locations of the hard drives supported by the subsystem and give instructions on installing a hard drive The subsystem supports hot swapping allowing you to install or replace a hard drive while the subsystem is running 2 2 1 Installing a SAS Disk Drive in a
15. sesnsseseseseeesessess 18 2 2 2 Installing a SATA Disk Drive Dual Controller Mode in a Disk Tray sss 20 23 Connecting the JBOD SHDSVSETOLTI icio ied bt tratte iste EI ee aiaa iE n teens E i duchess 22 Ral Connecting tO SAS HDA M RR uU EE 22 232 C nnec ng to RAID SU Sy SI adc a e ent diente EE 22 Chapter 3 Maintenance ccccccccccccsccssssssssssssccccccccssccccccssssscssssssssscccscssscccccsssees 23 sA UD n A O a E E E N 23 3 2 Replacing JBOD Subsystem COoMponentS se sseeeseeessoeseonssenssonseonsessstsssensesosseessenssenstesstosstesnteossenssrossrnssresss 25 3 2 1 Replacing JBOD Controller Module ccsssessesesssssessscsssesssssssesesssssssssseseessseseesssesesssseseseeseseeeesees 25 3 2 2 Replacing Power Supply Fan MOdSUlG itii e reete terne er tret Parere estet 26 3 2 2 1 Replacing Power Supply Fan Module with Plate Cover sse 27 EE User Manual SAS to SAS SATA II JBOD Subsystem Chapter 1 Introduction The 16 bays EPI Ca JBOD Subsystem The EPICa EP 3163 J D S3S3 is a 19 inch 3U rackmount J BOD unit It comes with 16 hot swappable bays and is the Proware s most versatile SAS SATA II Disk Expansion system ideal for high capacity and scalability storage in most popular OS environments Based on 3Gb SAS Channel host interfaces the EP 3163 D S3S3 supporting the choice of SAS and SATA II drive configurations to deliver the best cost performance index with higher bandwidth The ability to mix
Download Pdf Manuals
Related Search
Related Contents
remko atk25 Philips Neckband Headphones BSF1614CR-CN HP Pro x2 612 G1 Copyright © All rights reserved.
Failed to retrieve file