STD35 Telemetry module User Manual
Contents
1. are not allowed to exceed 1000W per relay e The maximum voltage is 250V AC alternating current e The maximum switching power per relay is 6A depending on the width of the PCB tracks e No special operation position of the device has to be observed e When installing the device make sure that the supply cable has a sufficient diameter e During operation the temperature has to be between 20 and 55 Celsius e Incase of condensation allow a period of about 2 hours for acclimatisation e Keep away the device from flower vases bath tubs washbasins liquids etc e The device is meant for operation in dry and clean rooms e Protect the device from humidity spray water and heat e Do not expose the device to heavy vibrations e Do not operate the device in areas where are or could be inflammable gas vapours or dust e The unit may only be repaired by a specialist e Only original parts have to be used when repairing the unit The use of differing spare parts can cause serious material loss or personal injury Proper Use The device is designed for the remote switching of devices via the GSM network as well as the remote retrieval of status information of the inputs and the generation of SMS messages after status has changed at the inputs A different utilisation of the device other than the one described above is not allowed Introduction The STD35 is a telemetry module which is easy to install and simple to use With the STD35 yo
2. for it Your IMEI number is visible on the GSM module AUTH NTNU UI mininin S N 348000 AAARA Made in Taiwan e2w59 The last 4 digits of the IMEI are therefore the password for your device and should be kept secretly from your side The IMEI number cannot be changed You can also change the password for security relevant cases but please bare in mind that each command also the reset to the factory status will presumes the knowledge of this password Control Commands via SMS Control commands via SMS will only be executed if the phone number of the sender has been communicated to the STD35 before Control commands don t need a password All command with exception of R and ST have to be terminated with a dot All commands can be sent in one SMS separated one from the other by the terminating dot The indications of the seconds can have 1 5 digits Valid indications are e g 1 or 90 or 99999 that means there won t be put leading Zeros before the digits e g 01 90 This is euiqvalent of 90 seconds Please pay attention to the difference between the number 0 and the letter O O10N Contains two times the letter O whereas O1 0 contains once the letter O and once the number 0 Basic functions e After having been called from the assigned stored pls See configuration call mobile phone the relay 1 switches for a second e When the digital input1 will be activated for a second the STD35 s
3. MHz Class 1 1W 1800 MHz Temperature range 20 C 75 C Weight approx 160g Dimensions 130x85x30 mm LxBxH Supply voltage 5 32V DC Idle current 32 mA peak current up to 500 mA Max Switching current 5 A Max Switching voltage 30V AC e Input voltage digital inputs logic 1 5 20V logic 0 lt 1 5V case of technical problems and questions concerning the STD35 our Hotline is available for you Mo Fr 9 00 a m 5 00 p m Techn Hotline 49 0 89 4902 686 11 For other questions about the STD35 please dial Sales 49 0 89 4902 686 29 Issue April 2005 Subject to change without notice Telic GmbH Raiffeisenallee 12b D 82041 Oberhaching www telic de info telic de
4. Return button Troubleshooting Problem Possible reason Solution GSM LED stays dark No supply voltage Please connect power supply GSM LED is blinking from the beginning twice cyclicly No SIM card No contact to the SIM card Surface of the SIM card to clean GSM LED is blinking from the beginning thrice cyclicly PIN is Not 0000 SIM card PIN to be set to 0000 GSM LED constantly on No GSM Network available No Antenna connectec Antenna to connect please change position of antenna GSM LED gets dark after about 3 minutes Not configured Configuration Call to be done STD35 does Not react on configuration call not Device is already configured Please Reset to Factory settings accepting the call STD35 does Not react to Wrong IMEI Number in the SMS IMEI Number to be checked SMS Configuration SMS SMS not yet delivered delivery can take some time STD35 doesn t react on SMS The Mobile phone doesn t send Please configure Mobile phone in or Calls even though being the phone number Incognito the way that the phone number is booked to GSM Network Mode also transmitted Both red LEDs blink The configuration call hasn t been Please do configuration call consecutively done yet Technical Data e GSM Dual Band EGSM 900 1800 MHz compatible with ETSI GSM Phase 2 Standard Output power Class 4 2W 900
5. STD35 Telemetry module 0682 User Manual Table of contents Subjects Page Important Information Advice Safety instructions Operation conditions Proper use Introduction Connectors and LEDs Startup General aspects Configuration call Usage Tracking via GPS Modem functionality Trouble shooting Technical data Ooo RA RWWOYNNOA Important Information This user manual contains important information for startup and use of the STD35 Read it carefully before you start working with the STD35 The warranty will be null and void should damage occur due to non compliance with these instructions for use We cannot accept any responsibility for consequential loss We cannot be held responsible for material loss or personal injury that is due to incompetent use or non compliance with the safety instructions The warranty will be null and void in such circumstances The STD35 contains highly integrated components which can be damaged by electrostatic discharge A Therefore only touch the STD35 on the edges and avoid to touch the pins of components Ate onthe board Advice The one who makes the module operational by adding further components or putting it into a housing is seen as manufacturer according to DIN VDE 0869 and obliged to hand out all necessary documents with the device and to indicate his name and address Devices which are made out of modules have to be considered as an industrial product from t
6. a In this case also a SMS containing O10N from the assigned mobile phone will switch the relay 1 on permanently A SMS with the content O1OFF will then switch the relay 1 again off permanently Accordingly the relays 2 to 5 will react on SMS messages which contain OxON And OxOFF x 2 5 e ByaSMS with the content e g l1 xxx xxx seconds the times can be programmed for the five inputs during which these inputs have to be active before the STD35 will send out an alarm SMS The inputs 2 to 5 show the identical behavior e By a SMS with the content e g V1 x Or V2 x x 1 oder 0 the polarity of the inputs can be inverted In case of x 1 there will be sent a alarm SMS if the input was deactivated longer then the configured time For the inputs 3 to 5 equivalent proceeding is valid e g V4 x Using the SMS S x x 1 or 0 the Start SMS START UP ALARM can be switched on or off The SMS R will set back the device into the factory status Via the SMS ST you can ask for a response SMS from the STD35 with the actual status of the inputs and outputs The same functionality can be achieved pushing the button on the upper side of the STD35 being under the LED Please consider that each of the pushings will lead to the sending of a SMS and so will create costs for you With the SMS e g for the outputs 1 and 2 A1 xxx Or A2 xxx x seconds you can adjust the dela
7. ed in a very flexible way Even the Reset into the factory status e g to proceed for y new configuration call is possible The configuration via SMS is described under SMS commands Configuration Call Please wait until the GSM LED has started to blink Then please call with the mobile phone which is assigned to control the STD35 the phone number of the SIM card being inside of the STD35 The call will be accepted by the STD35 and will be terminated a couple of seconds later As a control sign five signal tones will be sent via DTMF sequences They can be heard during this call on your mobile phone Due to this call the STD35 will be adjusted to the corresponding mobile phone it will log Your phone number that has been transmitted Therefore please take care that_your mobile phone will transmit the phone number means the GSM function incognito or private call has to be switched off This is a configuration that you can settle on your mobile phone in which you put in the SIM card For testing this feature you can call another mobile phone there your phone number or name have to be displayed In case the STD35 e g due to being separated from the supply voltage the STD35 will send after the reapparition of the supply voltage automatically an SMS with the content START UP ALARM being sent to the configured phone number Please consider When the STD35 is not confirgured in factory status neither by co
8. ends a SMS with the content EVENT ALARM 1 to the assigned mobile phone e When the digital input2 will be activated for a second the STD35 sends a SMS with the content EVENT ALARM 2 to the assigned mobile phone e The same is certainly valid for the inputs 3 to 5 Switching via SMS e After having received a SMS with the content O1ON Output 1 ON from the assigned mobile phone the relay 1 will switch for a second In case of a SMS O2ON The relay 2 will switch for a second e The same is certainly valid as well for the outputs relay 3 to relay 5 e In the case that the switching time has been put to 0 number 0 the relays switch permanently to the other status Configuration SMS e The configuration SMS is valid only if beginning with the 4 digit password Teh CLIP of each of the configuration SMS will if the password is correct be logged automatically as a new administrator Therefore it has to be considered that the configuration only is executed from the mobile phone of the administrator e With a SMS having the content O1 xxxxx character O xxxxx seconds the switching times of the relays can be configured The STD35 will keep these configurations even after the cut off from the supply voltage e Incase that the switching time for a relay has been put to 0 the STD35 will at each new call switch the related relay permanently Has the relay been active before it will go to inactive and vice vers
9. he inputs and outputs The LED Output Event blinks shortly when one of the 5 relays is activated the LED Input Event when one of the 5 inputs is controlled Please take into account the maximum switching current of the relays and the maximum input current and voltage of the Opto couplers In the chapter Startup you will find further information for it Startup For the installation of the STD35 you need a released SIM card of a GSM network provider on which the PIN has been put to 0000 To change the PIN accordingly you can use a regular mobile phone Please get the proceeding for Pin change out of the corresponding user manual of your mobile phone In case of using a SIM card with another PIN than 0000 the STD35 will use a wrong PIN during each power on which leads to blocking of the SIM card after the 3 trial When this happens you have to assign a new PIN number using the Super PIN PUK Please get related advice for the change of PIN number and reset of blocked PIN number with the PUK out of the user manual of your mobile phone In case your want to use a SIM Karte without PIN this is possible as well the STD35 recognizes this and is running accordingly Before connecting the supply voltage please enter the SIM card into the SIM card holder on the rear side of the STD35 Displace the moving part of the SIM card holder a little bit and open it Enter the SIM card into the moving part close it again and fix i
10. he safety perspective During use of the STD35 Short Messages SMS can be generated automatically Costs may occur for you by this SMS traffic Safety Instructions to be observed Especially VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 and VDE When using products which are exposed to electric voltage the valid VDE regulations have 0860 are applicable e Before opening of a device always pull the mains adapter or make sure that the device is disconnected from the power supply e Components modules or devices have to be build into a housing before they are put into operation During installation they should not be connected to any power supply e You should only use tools on components modules or devices if they are disconnected from the power supply and the electric charge which may still be stored in some components inside the device has been discharged e All cables and wires which are energized and connected to the device the module or components have to be checked regularly for any damage of the isolation shield or fractures of the cables If the supply cables are visibly damaged the device has to be taken out of operation immediately until the faulty cable has been exchanged e When using components or modules it is necessary to strictly observe the specification given in the corresponding description of these components e lf a description for a private end customer not clearly states which electric data is valid for a comp
11. ion can be launched from the Admin respectively the 4 additional Masters durchgef hrt werden The users who are in the extended Cliplist can Not use this function To ask for actual position of your STD35 please use the following SMS commands GPS After reception of this SMS the STD35 sends a SMS with the following text to your mobile phone GPGGA lt 1 gt lt 2 gt lt 3 gt lt 4 gt lt 5 gt lt 6 gt lt 7 gt lt 8 gt lt 9 gt M GPGGA 083537 00 4802 00364 N 01135 21171 E 1 4 7 95 579 8 M 47 5 M 61 1 UTC time hh 08 mm 35 ss 37 00 corresp 09 35 37 MEZ 2 Latitude Latitude 48 Degrees 02 00364 Minutes 3 Hemisphere N nordic Latitude 4 Longitude Longitude 11 Degrees 35 21171 Minutes 5 Hemisphere E eastern Longitude 6 Position fix 0 No fix 1 GPS SPS mode 2 DGPS mode 3 GPS PPS mode 7 Number of Satellites 4 Satellites used for Position 8 horizontal Precision Precision of the Position 7 95 Meters 9 Height over sea level 579 8 Meters Unit of height M for meters 10 Age of the GPS Data here No DGPS used A GPS tracking can also be asked by call This function however is only possible for the Admin and the 4 futher Masters For being able to use this function the default status call switches relay 1 has to be changed by the Admin This is done from the Admin s side sending a SMS with the following content 2759 G1 x x 0 Calls from Admin and the Mas
12. mands E1 lt text1 gt E2 text2 gt Up to E5 lt text5 gt And PT lt startup text gt Within the texts no SMS command for configuration is allowed and the final dot is terminating the text Each text message can have up to max 64 characters Each text input has to be done in a separate SMS Table of SMS Commands Factory settings R Status of I Os ST Start SMS on off 1 S 0 Relay 1 on O10N Relay 1 off O10FF Relay 2 on O2ON Relay 2 off O2OFF Relay 3 on O30N Relay 3 off O30FF Relay 4 on O40N Relay 4 off O4OFF Relay 5 on OSON Relay 5 off OSOFF Switching time Relay 1 O1 xxxxx Seconds Switching time Relay 2 O2 xxxxx Seconds Switching time Relay 3 O3 xxxxx Seconds Switching time Relay 4 O4 xxxxx Seconds Switching time Relay 5 O5 xxxxx Seconds Delay before reply Relay 1 A1 xxx Seconds Delay before reply Relay 2 A2 xxx Seconds Delay before reply Relay 3 A3 xxx Seconds Delay before reply Relay 4 A4 xxx Seconds Delay before reply Relay 5 A5 xxx Seconds Time of activation Input 1 11 xxx Seconds Time of activation Input 2 I2 xxx Seconds Time of activation Input 3 13 Xxx Seconds Time of activation Input 4 14 xxx Seconds Time of activation Input 5 15 xXxx Seconds Invert Input 1 V1 x x 1 0 Invert Input 2 V2 x x 1 0 Invert In
13. nfigurations call nor by SMS it will show this by alternative blinking of the LEDs Input Event and Output Event It is switching off after 3 minutes autonomously when not being configured within this time slot A renewed connecting to the power supply will switch on the STD35 anew and it is expecting again a configuration Usage After being configured the following functions of the STD35 will be at your disposition Switching per call Please call after made configuration the phone number of the SIM card being inside of the STD35 Please take care that your mobile phone is transmitting the phone number see as well configuration call The relay 1 will then depending on the configuration switch for a certain time factory status 1 sec The relays status LED Output Event is on during this period Launch an Alarm SMS Put for 1 second Factory configuration a voltage of 12V at one of the inputs consider the polarization Then an alarm SMS will be sent to your mobile phone The LED input event is shortly flashing up when you put the voltage to the STD35 Sending SMS commands Your STD35 can launch switching processes as well as be configured via an SMS that you send to it The Format of the Configuration SMS To protect your STD35 against not authorized access each of the configuration SMS to the STD35 has to begin with a 4 digit password The factory default provides the last 4 digits of the IMEI number
14. onent or a module how to wire the device which external components or additional devices can be connected or which parameters these components are allowed to have a specialist must be contacted e Before putting a device into operation it has to be clarified whether this device or module is meant for the field of application In case of doubt ask specialists or the manufacturer of the device e Please note that we are not responsible for any errors in usage or connection Therefore we cannot accept any responsibility for consequential loss e Devices which operate with gt 35 Volt have to be connected by a specialist e Before putting the device into operation it should be checked that there is no current leakage on the housing e In case that measurements with the opened housing are necessary an isolating transformer has to be integrated for saftey reasons Alternatively the voltage can be supplied by an appropriate power supply which complies with the safety regulations All wiring work has to be done in a voltage free state only Operating conditions e Operate the STD35 only with a supply voltage between 5 32V and have in mind the polarity see picture1 The power supply has to deliver at least 500mA If you use a mains adapter for power supply it has to be conform with the VDE regulations e Devices with an operating voltage gt 35 Volt have to be installed by a specialist observing the VDE regulations e Loads connected to the device
15. put 3 V3 x x 1 0 Invert Input 4 V4 x x 1 0 Invert Input 5 V5 x x 1 0 2 Alarm number C2 lt number gt 3 Alarm number C3 lt number gt 4 Alarm number C4 lt number gt 5 Alarm number C5 lt number gt New Password PN lt 4digit password gt Event Text 1 E1 lt text gt Event Text 2 E2 lt text gt Event Text 3 E3 lt text gt Event Text 4 E4 lt text gt Event Text 5 E5 lt text gt Start Up Text PT lt text gt Add Clip to the extended Cliplist CL lt nummer gt Remove Clip from the extended Cliplist CD lt nummer gt Examples for SMS Commands Configuration using control command Start message Off Relay 1 On Relais 2 Off Time of activation of input 1 5 sec 2759 S 0 010N 020FF 11 5 The sender of this SMS is from now on Administrator Configuration Switching time of Relay 1 90 Sekunden 2759 01 90 Configuration Reset to factory settings 2759 R Configuration of a 2nd Alarm number 2759 C2 491721234567 Erasing of an Alarm number 2759 C2 Configuration of a new password 2759 PN AB12 New Number in extenden Clip list 2759 CL 491721234567 Remove Number from extended Clip list 2759 CD 491721234567 Control commands O10N O20FF O30N Tracking via GPS By plugging of an appropriate GPS Mouse on the serial connector DSUB 9 of the front side of the STD35 you can transmit the GPS data directly to your mobile phone This funct
16. t by slight displacing Please consider the position of the SIM card especially the position of the flat corner If not yet done please connect and tighten the GSM antenna After that please establish the connection to the supply voltage The GSM LED shortly after begins to shine steadily The STD35 will try now automatically to book into the GSM network As soon as the STD35 is booked into the GSM network the GSM LED once for around all 2 seconds General aspects Your STD35 can basically be configured in 2 ways 1 Configuration Call easy setup In factory status the STD35 can be configured by a call within the first 3 minutes after connecting to the supply voltage In this case is logging the phone number from which this call has been made supposing that this number is transmitted and will report future event to this phone number You can switch by a call from this phone from now on known to the STD35 also one of the relays The total STD35 can so be configured by call in which it is remembering the phone number for simple applications You don t need a PC for it and don t need to send SMS neither 2 Configuration via SMS professional setup For more complexe tasks e g the switching of the 5 outputs the configuration of several persons being authorized to switch or get event messages the modification of the standard texts and a number of further parameters the STD35 via SMS configured and controll
17. ters switch Relay 1 factory setting x 1 Calls from Admin or the 4 Masters launch a tracking request for which the reply will be sent back exclusively to the number having called For the possible 90 Users on the extended Cliplist it is still possible to switch the relay 1 by call even though the command lt 2759 G1 1 gt has been sent from the Admin s side Please consider that for the connection of GPS mouse probably a Zero Modem adaptor has to be put between the RS232 connector of the STD35 and the GPS mouse Modification of the Baudrate for different GPS Mouses Since GPS Mouses from different manufacturers work with different baudrates the baudrate of the STD35 can be put to 9600 Baud and 4800 Baud Therefore the following configuration command has to be sent to the STD35 2759 BR x x 0 Baudrate 9600 Factory setting x 1 Baudrate 4800 Baud Modem Functionality of the STD35 For using the Modem functionality of the STD35 the serial interface has to be modified using a terminal program The STD35 is put to 9600 Baud 8N1 as the factory setting After connecting the RS232 with a terminal program on the PC just the simple command lt at gt has to be sent Then the user has the full GSM modem functionality at his disposition During the Modem functionality the GPS funktionality is deactivated To reactivate it a command via the terminal program has to be sent to the STD35 This command is as follows at e2apc 2 3 pushing the
18. u can control five relays and monitor the status of five digital inputs with one or several common mobile phones Apart from the STD35 you only need a valid SIM Card of any network provider GSM 900 1800 MHz While using prepaid SIM cards one shall always keep himself aware of the amount left on the card so that in case of alarms a SMS could be sent Typical fields of application are the opening of garage doors switching on and off light and alarm devices as well as generating alarm messages SMS or the retrieval of information from door sensors movement sensors or level sensors etc Connectors and LEDs Connection Scheme of the 12V DC Voltage Supply Figure 1 As described in figure 1 the STD35 has 6 screw terminals for the digital inputs and 6 screw terminals for the Relay outputs Screw terminal 1 is the common negative reference point for all 5 digital Inputs The terminals 2 to 5 are the positive reference points for the after coming opto couplers On the output side are further 6 screw terminals from which the terminal 12 represents the common reference point and switching potential for all 5 relays On the PWR the power supply of the STD35 will be connected On the connection ANT the GSM antenna is to screwed in connector type FME When the module is booked into the GSM network the green GSM LED is blinking at the front side about once within 2 seconds The LEDs Input Event and Output Event signalize the Status of t
19. y after which after a switching the status will be sent in the response SMS This ist e g very helpful if you launch a switching and you measure the result of the switching on an input of the STD35 Using this the changed status after the switching will be signalized For the outputs 3 to 5 the same behavior will happen The command PN lt 4digit password gt will change the password The password can consist in 4 freely chosen numbers or character combinations special signs are not allowed Characters within the password have to be written in capital letters In factory status the password is always the last 4 digits of the IMEI see also chapter SMS commands You can define up to four further alarm numbers master numbers C2 C5 to which also Start and Event SMS will be sent These numbers can also switch the relay 1 by call and can execute other control commands via SMS Configuration SMS though can only be sent successfully from the administrator s side If the alarm numbers are entered in international format they have to start with a You can give authorization to up to one hundred of further phone numbers to switch the relay 1 by call To do so you have to build up the extended Clip list respectively you have to enter phone numbers into this Clip list You can also using CD erase again phone numbers within this list The texts for Event respectively Start up messages can be modified using the com