the push-fit solution for underfloor heating

image

Contents

1. UNDERFLOOR Kiwa henchmark ll a Speedfit PEX Fittings i A BRITISH HEATI H G and Barrier Pipe J The code of pr actice for the installation BOARD OF MAALT ACEUAPAS ASSOCIATION K24076 K24077 and K24078 commissioning amp servicing of gas fires and wall heaters rooney AGR MENT JS Speedfit UNDERFLOOR The Speedfit System for Underfloor Heating has been designed to be as quick and easy as possible to install with component parts manufactured under an ISO9001 Quality Management System The System has water pumped from a boiler or other heat source to a pump pack where it is mixed to approximately 50 C then distributed via a manifold to heating circuits made using Speedfit Barrier Pipe The temperature and volume of water altered to maintain the requirements of the system The pipe is laid in concrete or suspended just below the surface of timber flooring A wide range of electrical components means the system can have as much or as little control as required Design Service and Technical Support CAD Design Service Members of the Technical Support Team are available to help you get the best from your Speedfit Underfloor Heating System To obtain an estimate send us a plan of the area where underfloor heating is required indicating the preferred location of the manifold and intended floor finishes An estimate will be prepared and when approved and an order placed the Speedfit CAD Design Service will prov
2. k G LLL 13 JS Speedfit UNDERFLOOR Network Software Options The software options allow the user the luxury of convenient control of the heating system e Direct from a home computer From a laptop via the internet e By texting from a mobile phone PC NETWORK SOFTWARE SOFTWARE FEATURES e Temperature View See at a glance the actual and set temperature for each thermostat throughout your building e Program Comfort Level Program the comfort level for each thermostat on the network e Holiday Program a holiday period e Override Feature Quickly override the set temperature for any thermostat e Keylock Lock the keypad remotely to prevent unauthorised alteration of the thermostat settings for all or selected thermostats switches the thermostats into frost mode during this period USB ADAPTOR Part No Description JGPCLITE PC NETWORK SOFTWARE Allows for the control of your UFH System from a remote location using a PC with broadband internet connection and loaded with the network software Can control up to 32 12 Volt Network Thermostats on a Windows based PC using either a direct USB connection or an Ethernet adaptor The Ethernet connection allows you to control your heating thermostats within you home network LAN or wireless network WAN and also remotely over the internet Part No Description JGPCPRO NETWORK SOFTWARE The System is as JGP
3. Installing of UFH Staple System Using the screed as a heat diffuser JG Speedfit pipe is secured with staples to rigid insulation placed over the concrete sub floor A variety of screeds can be used and are typically 65 75mm thick for sand cement types or 40 50mm for liquid pumped screeds The system is quick to install cost effective and can be easily adaptable to irregular room shapes Floor coverings can be laid when the screed is fully cured STEP To prepare the floor insulation should be fitted to a flat sub base The joints should also be taped and a membrane placed over the insulation STEP 4 Using the staple gun fix the pipework to the installation in the desired pattern see images on patterns of pipework Starting the first circuit 75mm from the perimeter and staples should be approximately 500mm apart More staples maybe needed on bends THINGS TO REMEMBER STEP 2 An expansion strip is required around the perimeter of the room to accommodate the expansion which will occur within the screed as a result of heating up This should be fitted around the perimeter of the room and taped to the membrane STEP 5 When using the pipe unroll it from the outside of the coil and do not try to uncoil it from the centre this will make the process easier Keeping the first run of pipe around the perimeter straight and using a gauge to keep the designed pipe centres even will also help the installation process e Insulatio
4. nternet Connection ee SOFTWARE OPTIONS uspagarToR Control your underfloor heating from a home computer via the internet n a or from a mobile phone Pages 4 and I5 m Direct USB Connection Mains Voltage Electrical Control System Slimline and attractive components with a Touch Screen Time Clock and a choice of room thermostats Pages 16 and I7 6 Wireless Control System Slimline and attractive components which are easy to install and reliable with upgrade options Pages 18 and 19 gt System Components Manifolds pumps pipe fixing systems and much more to help you complete your installation Pages 20 and 21 Underfloor Heating for Conservatories and Extensions Single Room Control Units Underfloor Heating Packs everything you need to install a system of up to 30sqm Pages 22 and 23 Installation Guides Easy to follow guide on completing your installation Pages 24 to 3 Energy Saver System A radiator system with individual zone control Pages 32 and 33 www speedfitUFH co uk JS Speedfit UNDERFLOOR Underfloor Heating Underfloor heating provides the most comfortable even warmth of any heating system It is economical to run and virtually maintenance free The Speedfit System has water being pumped from a boiler to a pump pack where it is mixed to approximately 50 C then distributed via a manifold to heating circuits made using Speed
5. this is called balancing the system This is achieved by lifting the locking ring at the base of the flow guage and twisting the glass shroud e Insulation depth as required by design or building regulations and to ensure that any downward heat loss does not exceed 10 watts per m 2 in accordance with BS EN 1264 e Decorator caps can be used for manual isolation of a circuit and will usually be replaced by Electro Mechanic Actuators for fully automatic control www speedfitUFH co uk STEP 3 Connect the pipework to the manifold following the guidelines for fitting JG pipe and fitting It is best to start from one end of the manifold and work to the other The use of JG conduit elbows will make the process easier and neater and enable the conduit to be inserted into the socket end STEP 6 The designed temperature through the circuits is controlled by turning the blending valve knob to the desired temperature JS Speedfit UNDERFLOOR Installing the JG Mounting Rail Using the screed as a heat diffuser Speedfit Pipe is secured to Clip Rails on top of rigid insulation which is placed over the concrete sub floor A variety of screeds can be used and are typically 65 75mm thick for sand cement types or 40 50mm for liquid pumped screeds The system provides ready made pipe spacing can be fixed to insulation which is too thin for staples and is especially suitable for large regular shaped areas Floor coverings c
6. Advice It is important to carefully consider the ideal installation method for your underfloor heating project The pipe fixing technology offered by JG Speedfit Underfloor Heating will ensure that the right materials and methods are used for the job s requirements Step by step Installation Guides Installing the Manifold The installation of the manifold is an integral stage of a heating system The JG Speedfit manifold kits are for use on underfloor heating or radiator systems The manifold consists of two rails one for the flow and one for the return complete Installations normally fall within three categories SOLID SCREEDED FLOORS The screed is an important and integral part of the UFH system transferring energy from the pipes to the area to be heated The response of this thermal mass will depend on its depth and make up The usual depth of screed is 65 75mm thick but it is possible depths can be reduced to assist in improving performance It is suitable for us in either new build or existing properties PIPE LAYOUT IN SOLID FLOOR INSTALLATIONS The shape of the room and the position of the outside walls and windows will determine the pattern of the pipe layout The counterflow pattern is recommended although other options are shown opposite TIMBER FLOATING FLOORS Often found in the upper floors of a property a system is required where a solid floor installation is not suitable due to structural
7. as it removes a layer of resistence to heat transfer STEP Plates need to be supported so that they sit level and make a good contact with the floor placed on them from above Maintaining this contact is essential in producing good heat transfer performance STEP 4 Fix the plates to the top of the joists ensuring the fixing will not protrude and prevent the floor from having a good contact with the floor 18mm staples fixed using an air stapler is the preferred method Allow 300mm for pipe end returns and a 5mm gap between plates Use a short length of pipe pressed into the grooves to line up the plates before fixing KEY DATA STEP 2 Some time spent planning the installation will save time later and make installation easier The main consideration is the amount of runs and the route those pipes will take from the manifold STEP 5 Run the pipework to the designed or desired pattern being careful to ensure the plates remain flush with the top of the joists The pipework can enter the plate system at either end or in the centre pipework can be cabled through joists or via grooves at the top of the joists Consult building regulations to ensure compliance STEP 3 Battens should be fixed along the length of the joist 5mm plus the depth of insulation board being used down from the top of the joists in order to support the insulation along its length This will allow a 5mm gap between the surface of the insulation and the t
8. conventional underfloor heating wiring centre TOUCH SCREEN TIME CLOCK 8 ZONE WIRING CENTRE PROGRAMMABLE ROOM THERMOSTAT PROGRAMMABLE ROOM THERMOSTAT PLUS HOT WATER TIMER DIAL SET BACK ROOM THERMOSTAT Part No Description JGTM4 TOUCH SCREEN TIME CLOCK e Touch Screen technology e Operates up to 4 zones e 4 different time settings per day e Holiday function Designed to be used with JGDSSB Dial Setback Room Thermostat see page 7 and the UH3 Wiring Centre A mains voltage Touch Screen 4 Channel Time Clock that can be set to a 5day 2day or 7 day programme mode and has the facility to operate up to 4 different time settings per day The 4 zones can be used to control underfloor heating radiator heating or hot water A copy facility makes for easier programming Whilst a holiday function will put the system into permanent set back mode while you are away from the property Note that Programmable Room Thermostats do not need the control of a separate time clock as they have their own built in time and temperature facility Part No Description JGUH3 8 ZONE WIRING CENTRE e Easy to wire e 4 time clock connections Easily wired up the wiring centre offers a simple solution for the control of Underfloor Heating plus hot water and radiator circuit conveniently allowing all to be wired to a central base Of 4 Time clock connections 2 are dedicated for setback zones and 2 are user selectable
9. for hot water towel rail or radiator circuits Neons indicate Zone Power Water Pump Boiler and Motorised Valve operation Dedicated connections for Boiler UFH Pump UFH Motorised Valve 4 Channel Time Clock Actuators etc JGUHS can also be used for the control of Energy Saver Radiator Zones See Page 26 Part No Description JGPRTE PROGRAMMABLE ROOM THERMOSTAT e Individual zonal temperature control 5 day 2 day or 7 day programme e Multi functional A slimline Digital Programmable Room Thermostat to give individual time and temperature control on a 5 day 2 day or 7 day programme to allow for different time settings for every day of the week providing total flexibility Offers the facility of up to 4 different time and temperature settings per day The thermostats are multi functional and self learning This means that to avoid unnecessary use of energy the thermostat will delay the heating start up until the last possible moment needed to achieve comfort level at the programmed time The thermostat features a large backlit display which makes for easy reading when in use and has the facility to connect to a remote probe part number JGPROBE see page 10 A holiday function reduces the set temperature to a frost setting during a holiday period and reverts back to comfort level at the end of a predetermined period Part No Description JGPRTHW PROGRAMMABLE ROOM THERMOSTAT PLUS HOT WATER CONTROL e In
10. inhibitors the following manufacturers should be contacted Fernox Manufacturing Limited on 01799 550811 or Sentinel BetzDearborn Limited on 0151420 9595 e Paint and Chemicals Only use water or oil based paint DO NOT ALLOW CONTACT WITH cellulose based paints paint thinners or strippers solder flux or acid based descalents or aggressive household cleaning products e Exposure to sunlight Speedfit products when used indoors are not affected by sunlight When used out doors protect from ultra violet light by lagging or painting e Pipe Inserts Must be used on all installations when using plastic pipe and should be fully inserted e Electrical Components Electrical products in the Speedfit Underfloor Heating System are designed only to be used in U K Electrical Supply situations e Electrical Continuity If Speedfit is used in an existing metal system which may have been used for earthing electrical continuity should be reinstated e Collet Clips White and Grey collet clips are used with standard fittings to prevent accidental pipe disconnection Red or blue clips provide colour coding of pipe Red and blue clips should not be used to prevent accidental release of pipe e Pre Screed System Testing To ensure the pipework has been installed correctly and prior to the screed being laid it is essential that the system is checked and hydraulically wet tested Testing should be carried out at 2 bar for 10 minutes and 10 bar fo
11. remote probes JGPROBE PROGRAMMABLE ROOM THERMOSTAT PLUS HOT WATER CONTROL 8 ZONE WIRING CENTRE Part No Description JGSTATPLUS V3_ PROGRAMMABLE ROOM THERMOSTAT Room Thermostat which can be programmed in either 5 day 2 day or 7 day mode with an additional program for domestic hot water Thus hot water can be set to give 4 different timed control periods Can also be controlled using a TouchPad or PC or remotely using a PC with an internet facility Note there is no remote probe facility with this model REMOTE PROBE amp SENSOR BOX Part No Description JGPROBE REMOTE PROBE JGSENSOR SENSOR BOX Use with a JGSTAT V3 or a Touchscreen Thermostat Used in conjunction with a thermostat to control temperature in another room or to control floor temperature When using an air sensor install with a JGSENSOR Sensor Box Part No Description JGUHI 8 ZONE WIRING CENTRE Offers a simple solution for the control of underfloor heating hot water and radiator circuits that can all be wired to one central base This also brings the benefit of TouchPad or internet control to radiators and hot water as well as to underfloor heating Actuators boiler and pump connections are wired to a single point Used in conjunction with our Network thermostats and ideally installed near to the manifold the Wiring Centre provides individual control of up to 8 zones plus hot water Neons show Power Water Pump Boile
12. will be an easy task enabling this system to be installed in new or existing applications worldwide FITTINGS AND PIPE Speedfit offer a full range of Push fit fittings and pipe to cover any plumbing or heating situation Performance specifications are well within those required for most domestic plumbing and heating systems including mains feed cold water systems and vented and unvented hot water systems The system is approved by the British Board of Agr ment and the Water Regulations Advisory Scheme Speedfit PEM PSE and SFM Fittings and Speedfit Barrier Pipe are Kitemarked to BS7291 Parts 2 amp 3 Class S Licence No KM39767 MT TT Unlike conventional heating systems the other radiators do not receive heat when not wanted Study Bedroom Bedroom 2 Bathroom Signal for heat N y a E from Room Stat E iag gt mm Sy A ae aS J l l OT rr od l 240v Active Radiator Valve l pen l Kitchen Conservatory Dining Room l Unlike conventional heating systems no wasted heat goes Wiring to rooms not calling for heat Centre Living Room Radiator valve opens in l response to call for heat l Flow and return to boiler with Boiler and optional motorised valve Pump Fire The ability to properly control individual rooms according to their use appealed to us in a number of ways lt is energy efficient user friendly and is the way heating systems of the future nee
13. CLITE but allows the control of up to 900 network room thermostats Making the System suitable for hotels nursing homes schools and any situation where the temperature of the facility needs to be controlled from a remote location Part No Description JGUSB USB ADAPTOR a USB ADAPTOR E a _ Direct USB Connection A USB Adaptor that connects directly to a PC that has been loaded with JGPCLITE software so it can talk to the 2 volt network products The Adaptor can control up to 32 room thermostats Security Receive an email and text message when your home alarm is triggered Heating Control heating amp hotwater over web or SMS Interior Lighting Turn on or off your interior lighting whilst you are away by SMS or web ETHERNET ADAPTORS Part No Description JGNETADAPI Port Ethernet Adaptor controls up to 32 room thermostats JGNETADAPI 2 Port Ethernet Adaptor controls up to 64 room thermostats Connects to a PC with JGPCLITE software so it can talk to 12 Volt Network Products The Adaptor can be connected to a broadband router to enable the PC to talk to the system over the internet Internet Connection Ethernet Connection NET MONITOR Part No Description JGNETMON With built in software NET MONITOR Allows for communication over the internet fro
14. JGTAPE STEP 6 After installing the pipework JGTAPE can be placed over the end loops to prevent the pipework from becoming dislodged during the installation of the finished floor Floor Coverings Tiles slate ceramic etc use with Knauff Brio Board or suitable plyboard use with suitable plywood covering use directly over insulation as floating floor fix to battens between panels Applications New Build or renovation single or multiple rooms www speedfitUFH co uk JS Speedfit UNDERFLOOR Installing JG Overlay Joists and Battened Floors A grooved foil faced insulation panel for installing 5mm Speedfit pipe over existing floor structures between battens or under the floor between existing joists The system is a suitable choice for both new build and renovation projects Similar to other JG Speedfit Underfloor Heating systems a variety of floor coverings can be used The JG panels will prove an excellent installation method for optimising heat efficiency and lowering energy consumption STEP JG Underboard is intended to be used below flooring and supported firmly in contact with the underside of the flooring It is ideally suited to refurbishment projects As with all UFH systems additional insulation may be required to meet building requirements STEP 4 Grooves spaced at 200mm from centre of pipe or 67 5mm from edge of grooves the boards can be sized to accommodate most joist centr
15. JGUFHA 240 v 2 Description 240 v CIRCUIT ACTUATOR VALVE Controlled by a thermostat or programmer Actuator Valves operate to open or close the flow of water to an individual circuit on the manifold Pipe SPEEDPEX BARRIER PIPE Part No I 5BPEX 50C I 5BPEX 100C I 5BPEX 120C I 5BPEX 150C Description BARRIER PIPE BARRIER PIPE BARRIER PIPE BARRIER PIPE Size 15MM X 50M 15MM X 100M 15MM X 120M 15MM X 150M POLYBUTYLENE BARRIER PIPE Part No Description JGUFHSP400 390MM X 1000MM JGUFHSP250 390MM X 250MM JGUFHSP165 165MM X 1000MM Spreader Plates 390 x 1 000mm and 390 x 250mm are laid across traditional joists and fixed in place using a hand stapler Spreader plates 165mm x 1000mm are designed to be used with composite joists and are fixed from below Speedfit Pipe is fixed in the grooves of the plates insulation is placed in the void below the plates to minimise downward heatloss Above approx 2 plates per Im Below approx 4 plates per Im www speedfitUFH co uk Part No Description Size 5BPB 50C BARRIER PIPE 15MM X 50M 5BPB 100C BARRIER PIPE 15MM X 100M 5BPB 120C BARRIER PIPE I5MM X 120M 5BPB 150C BARRIER PIPE I5MM X 150M Offered in PEX or Polybutylene Speedfit Pipe has an inner barrier to prevent the ingress of atmosphere it is manufactured and Kitemarked to British Standard BS7291 Parts 1 2 amp 3 Class S It is lightweight and flexible making it especially suitabl
16. JS Speedfit THE PUSH FIT SOLUTION FOR UNDERFLOOR HEATING Celebrating 50 Years of Innovation Includes these NEW additions e Overlay Heating System e Manifolds e Wireless Heating Control System Many More Underfloor Heating Systems Energy Saver System MARCH 2011 John Guest Worldwide Connections The John Guest Group has a long established reputation as a world leading manufacturer of push in fittings tube and other fluid control products A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development Quality Manufacture A commitment to quality is at the heart of the John Guest Philosophy The strictest control is maintained by virtue of the fact that design and manufacture is carried out in modern purpose built manufacturing centres in west London and at Maidenhead in Berkshire Maintaining control over the whole process from initial tool design and tool making through to final assembly and testing ensuring that only products of the highest quality are produced The company believe it is this commitment to quality that has led to it receiving prestigious awards from many of the world s leading testing and approvals organisations John Guest is a preferred supplier to many international companies ISO ea rs TH 9001 a V phe British Gas WRA S E Service ApPage INDUSTRIAL BS7291 No KM39767 ASSOCIATE
17. SS STEEL Part No Description JGUFHMAN4 2 4 ZONE MANIFOLD JGUFHMAN6 2 6 ZONE MANIFOLD JGUFHMAN8 2 8 ZONE MANIFOLD JGUFHMAN10 2 10 ZONE MANIFOLD JGUFHMAN1 2 2 12 ZONE MANIFOLD JG Speedfit Manifolds are manufactured from stainless steel to the highest standards A unique feature is that connections to the heating pipes are Speedfit Push fit offering much reduced installation time All manifolds are pre fitted with brackets vibration isolation mounts and an automatic air vent Flow rate indicators include the means to adjust flow rate and isolate circuit Can be assembled to suit left or right hand supply depending upon project type MANIFOLDS BRASS Part No Description JGUFHMAN4 4 ZONE MANIFOLD JGUFHMAN6 6 ZONE MANIFOLD JGUFHMAN8 8 ZONE MANIFOLD JGUFHMANI0 10 ZONE MANIFOLD JGUFHMANI2 12 ZONE MANIFOLD MANIFOLD EXTENSION KIT NICKEL PLATED Part No Description JGUFHMANEXT 2 MANIFOLD EXTENSION KIT Stainless Steel and allows a manifold to be extended by one or more zones MANIFOLD EXTENSION KIT BRASS Part No Description JGUFHMANEXT MANIFOLD EXTENSION KIT CONTROL PACK NICKEL PLATED Part No Description JGCONTROL 2 CONTROL PACK A compact modular control pack for underfloor heating systems up to I4kW Designed to be lightweight in order to connect directly to Speedfit manifolds without the need for extra brackets or support The nickel plated material matches stainless JG Spe
18. Speedfit are registered trademarks of John Guest International Limited Copyright 2011 AVAILABLE FROM 22105 290 03 11
19. THERMOSTAT Part No Description JGWPRT WIRELESS PROGRAMMABLE ROOM THERMOSTAT Allows flexible location and ease of installation in domestic heating installations The programming mode allows for 5 2 or 7 day set ups at a 0 35 C temperature range With a battery operated range of up to 100m operating at a frequency of 868MHz the wall mounted thermostats are compatible with receivers JGWWC and JGWRC There are 4 heating levels and a holiday function which puts the system into a permanent set back mode while you are away from the property The thermostats are not compatible with other JG control ranges WIRELESS PROGRAMMABLE ROOM THERMOSTAT PLUS HOT WATER Part No Description JGWPRTHW WIRELESS PROGRAMMABLE ROOM THERMOSTAT Similar to a standard Wireless Thermostat JGWPRT with the addition of a 5 day 2day timer for domestic hot water Heating and hot water can be set to provide different timed control periods Thermostats are not compatible with other JG control ranges underfloor heating as well as radiator installations To extend the Wireless range wireless repeaters are available to boost the signal The system is a low cost and time efficient alternative as no cables have to be run WIRELESS REPEATER WIRELESS 8 ZONE WIRING CENTRE Part No Description JGBOOSTER WIRELESS REPEATER Mains powered this optional booster repeater is placed between a thermostat s that are out of signal ran
20. UCHPAD NETWORK CONTROLLER Manifold 4 The TouchPad features an easy touch screen control of up to 32 zones of heating You are able to name each thermostat allowing easy identification of each thermostat in the network remotely program the comfort levels of all networked thermostats from one central point Program settings can be copied from one thermostat to another Also has the option of being able to control the hot water and radiator circuits TFT Display New Features New TFT LCD offering a greatly improved viewing angle and display resolution Pi v3 Compatible The New TFT Touchpad is compatible with v3 thermostats Group Feature Allows the user to group thermostats for use with Profile function Profile Feature Allows the user to pre program a set of comfort levels apply them to a group of thermostats and store against a profile name When the profile is run the thermostats in the group receive the new comfort levels Zone Link Facility Linked zones appear as a linked button meaning that programmed comfort levels are sent to all of the linked zones USB Function e Ability to import pictures for screensaver operation e Export of history data e Update of firmware via Internet Download Heat Cool Function An upgrade will provide control for underfloor heating and cooling This firmware update will provide dew point control Language Function Dutch German French and English will be supported Be 3 D
21. UFH co uk SET BACK EXPLAINED Compared to other forms of heating underfloor heating has a relatively slow response time taking longer to heat up and cool down than say radiator systems In order to reduce running costs and to have realistic heat up and cool down response times rather than the system being switched off the temperature setting is reduced by about 4 C This is called set back because the system is turned down not off With the Speedfit System set back can be achieved in two ways Individual Programming Programmable Room Thermostats can be installed in each zone They give individual time and temperature control alternating between daytime and set back temperatures Centralised Programming The Dial Set Back Room Thermostat has its own Daytime and Set Back time controlled centrally using a Touch Screen Time Clock JSG Network Control System Low Voltage e Easy to install and use e Reliable Slimline attractive components e With upgrade options The new Underfloor Heating Network Control System from JG Speedfit differs from a normal underfloor heating system in that low voltage electrical components are networked together using computer network cable this one cable carrying signals between a wiring centre and all the components This system enables programming of time and temperature for individual rooms to be carried out directly at the room thermostat or c
22. an be laid when the screed is fully cured STEP Prepare the floor and insulation should be fitted to a flat sub base The joints should be taped and membrane placed over the insulation STEP 4 The mounting rail has double sided tape this may need to be supplemented with the use of JGUFHPIN depending on the adhesions of the installation THINGS TO REMEMBER STEP 2 An expansion strip is required around the perimeter of the room to accommodate the expansion which will occur within the screed as a result of heating up This should be fitted around the perimeter of the room and taped to the membrane STEP 5 The mounting rail is placed at about 750 800mm apart ensuring the slots are aligned neatly 1 5 to 2 linear metres of mounting rail per sq m of floor area pack per 20sq m e Maximum circuit length 100m of 5mm pipe e Maximum coverage Approx 100m centres sq m 200mm centres 20sq m 300mm centres 30sq m e Maximum heat output for 200mm centres 00Wsq m an apne gt i STEP 3 After establishing the area to be covered by the circuit connect to the manifold and start the circuit If the circuit has to pass through other heated zones before reaching the zone it is intended to heat conduit may be required STEP 6 A serpentine pattern is usually the most convenient to use with the mounting rail system Ensure to allow enough space at the end of the circuits for the flow and return from the manifolds
23. d to be installed We were so convinced we have installed it on a prestigious development in Boverton Steven Vanprag Summerhouse Point Development Ltd Lam installing the Manifold system in my new house like the idea of being able to turn off areas of my house that am not using Only paying for the heat in the rooms that want and when I want it seems obvious when think about it Royston O Riley Home owner Electrical Controls for use with Energy Saver System Choose from a range of Low Voltage Network Control Products TOUCHPAD TOUCH SCREEN THERMOSTAT PROGRAMMABLE THERMOSTATS AND WIRING CENTRE Mains Voltage Electrical Controls WIRING CENTRE TIME CLOCK DIAL THERMOSTAT PROGRAMMABLE ROOM THERMOSTAT AND ACTUATOR VALVE SPEEDPEX AND POLYBUTYLENE BARRIER PIPE www speedfitUFH co uk Technical Checklist Underfloor Heating e Applications Underfloor Heating Installations in solid or timber floors e Pipes 15mm JG Speedfit Barrier Pipe to BS 7291 Parts I 2 and 3 Class S e DO NOT USE Speedfit UFH Products for Gas fuel oil or compressed air applications e Floor Insulation Should be a suitable material and thickness to comply with current regulations e Minimum Bending Radii For Speedfit B PEX Pipe is 75mm e Expansion PEX Pipe 1 on length between 20 C and 82 C e Cleaners Inhibitors and Descalents For advice on the replenishment of additives such as corrosion
24. dividual zonal temperature control e Addition of 5 day 2 day hot water timer As JGPRTE but with an addition of a 5 day 2 day timer for domestic hot water Heating and hot water can be set to give different timed control periods www sp edfitUFH co uk Part No Description JGDSSB DIAL SET BACK ROOM THERMOSTAT Used in conjunction with a Touch Screen Time Clock JGTMA4 A modern easy to use Dial Room Thermostat with Set Back facility controlled from a centralised time clock JGTM4 The thermostat is set manually to Daytime temperature A Set Back mode reducing temperature by 4 c is controlled by a Central Timer Clock Part Number JGTM4 A manual override allows for permanent Daytime or permanent Set Back Neons indicate Daytime and Set Back mode and confirm if the room is calling for heat The thermostat also has the facility to be connected to a remote probe part number JGPROBE Speedfit UNDERFLOOR Wireless Control System e Easy to install and use Reliable Slimline attractive components e System can accommodate Underfloor Heating Zones or a combination of both The new Wireless Control System permits flexible location of thermostats in domestic heating installations The programmable thermostats work in conjunction with the Wireless 8 Zone Wiring Centre which is mains powered and is ideally suited to warm water WIRELESS PROGRAMMABLE ROOM
25. e Speedfit Underfloor Heating Control Unit is suitable for use when e The boiler serving the existing heating system has the capacity to take the extra output from 2KW to 3KW e The maximum area to be heated is 30 sq metres The Control Unit is designed to be used with Speedfit Barrier Pipe The amount of pipe needed is determined not only by the size and shape of the room but by the resistance of the floor finish to heat transfer Blending valve to control the temperature of hot water in the system Return to heat source e Ball valves allow for isolation from the primary system Return from underfloor e heating loop Anti vibration wall bracket ensures silent operation Flow to underfloor heating loop OPERATING PRINCIPLES The Speedfit Control Unit will operate automatically when the central heating circuit is on and the water temperature flowing through it has reached 40 C The pump will continue to run until the temperature of water flowing through it from the heating circuit falls to approximately 30 C Flow from heat source e 6 metre head pump Push fit for a fast connection to pipe The blending valve will maintain the temperature of the underfloor heating circuit by blending flow from the boiler with the cooler return flow from the underfloor heating circuit Underfloor Heating Packs Speedfit Underfloor Heating Packs consist of A Control Unit which is
26. e for underfloor heating installations For screed systems the pipe is attached directly to insulation with staples floor clips or mounting rails Spreader Plates are available for timber flooring using either traditional joists or engineered timber joists JS Speedfit UNDERFLOOR Underfloor Heating for Conservatories and Extensions SINGLE ROOM CONTROL UNIT Part No Description JGROOMPACK SINGLE ROOM CONTROL UNIT The new Speedfit Underfloor Heating Control Unit is the ideal way to provide heating to a conservatory or room extension up to 30m The unit is pre assembled and pre wired to allow for a fast and simple installation It can be plugged into any convenient electrical socket or spur The control unit has integral ball valves to allow for isolation from the primary heating system an adjustable blending valve and a six metre head circulation pump An _anti vibration mounting bracket ensures silent operation Speedfit push in connections make for a fast connection to pipework Speedfit recommend connection to the main central heating flow and return distribution system using a dedicated motorised valve It is also possible to connect to the nearest radiator supply pipe If connected to an existing radiator circuit the pump will be unable to operate independently only able to obtain hot water when the radiator system is on A full and detailed installation guide is provided with each unit Th
27. edfit Manifold Pack consists of a mixing valve circulating pump return elbow manifold adaptor and all necessary seals CONTROL PACK BRASS Part No Description JGCONTROL CONTROL PACK MANIFOLD ELBOW CONNECTOR NICKEL PLATED Part No Description JGUFHMANELB 2 MANIFOLD ELBOW CONNECTORS Nickel Plated and enables a pump pack and manifold to be installed at 90 C to each other MANIFOLD ELBOW CONNECTOR BRASS Part No Description JGUFHMANELB MANIFOLD ELBOW CONNECTORS Fixing Systems PIPE STAPLES Part No Description JGUFHGUN STAPLE GUN JGUFHSTAPLE PIPE STAPLES Pipe Staples are barbed to ensure a secure fixing to the insulation Easy fixing is carried out by using a Staple Gun securing the pipe to the insulation with an easy repeatable action box per 20m MOUNTING RAIL Part No Description JGUFHRAIL JGUFHPIN 2 METRE LONG RAIL PINS FOR ABOVE Mounting Rails offer a quick installation of 5mm pipe supplied 2 metres long the rails are pre scored every 100mm for easy cutting The rail can be secured using red Rail Pins pack per 20m Fixing Systems cont FLOOR CLIP Part No Description JGUFHCLIP FLOOR CLIP JGUFHTOOL FOR EASY FIXING OF FLOOR CLIPS Floor Clips screw easily into the insulation to retain 5mm pipe they are best installed using a Fixing Tool CONDUIT ELBOW Part No Description JGUFHCONELB CONDUIT ELBOW EDGE STRIP Part No De
28. entrally by choosing from a number of upgrade options e A range of de luxe Touch Screen Programmable Room Thermostats e Direct control of the whole system from a central TouchPad Controller e Software options to give direct control from a PC via the internet or from a mobile phone CAT5 cable is similar to telephone cable and used as computer network cable Beldon cable is best described as a heavier duty version of CATS it is easier to use than CATS and we would recommend Beldon cable be used on all installations However if using CAT5 cable ensure it is the shielded type It is important to connect Y and B Yellow and Blue communication cables using two strands from a twisted pair Mon 225774 j JS Speedfit UNDERFLOOR Network Control System Low Voltage PROGRAMMABLE ROOM THERMOSTAT Part No Description JGSTAT V3 PROGRAMMABLE ROOM THERMOSTAT Room Thermostat which can be programmed in either 5 day 2 day or 7 day mode Offers the facility of up to 4 different temperature settings per day The thermostats are multi functional and are self learning This means that to avoid unnecessary use of energy the thermostat will delay the heating start up until the last possible moment needed to achieve the comfort level at the programmed time Can also be controlled using a TouchPad or PC or remotely using a PC with an internet facility The thermostat also has the facility to connect to 2
29. es If the panel is too wide trim the material evenly from both sides to ensure a snug fit DATA 25mm OVERLAY BOARD STEP 2 Some time spent planning the installation will save time later and make installation easier The main consideration is the amount of runs and the route these pipes will take from the manifold STEP 5 Allow 300mm at the ends of the panels for the pipe return bends STEP 3 Battens should be fixed along the length of the joist 50mm down from the top of the joists in order to support the panels along its length Good contact between the surface of the panel and the bottom of the flooring is essential in maximising the performance of this system STEP 6 Pipework can enter the panel system at either end or even in the centre pipework can be cabled through joists or via grooves at the top of the joists Consult building regulations to ensure compliance Installing JG UFH Plate System From Above JG Speedfit s plate system is designed for use in timber suspended or battened floors the floor system uses aluminium single or double spreader plates to transmit the heat evenly across the finished floor surface They can be used as illustrated below a floor supported on insulation Alternatively where there will be a secondary layer of floor placed above a sheet sub floor the plates can be sandwiched between the floor layers supported on battens With a twin layer floor this second method is recommended
30. fit Barrier Pipe The pipe is laid in concrete or suspended just below the surface of the floor In concrete floors the pipe is laid on insulation and then covered with a DR Ceiling 18 C 24 C The heat is concentrated where it is most needed for comfort and efficiency screed on which can be laid almost any type of floor covering For timber floors spreader plates are laid between the joists and the floor decking or on the underside of the floor Speedfit Pipe is pushed into the grooves on the plates The floor area is typically warmed to between 25 C and 28 C providing an even distribution of heat at only slightly higher than room temperature The system is controlled by one or more thermostats which signal the Pump Pack when heat is required Ceiling 24 C Floor By contrast radiators transfer heat from a relatively small area at a much higher temperature than the space being heated The radiator system heats mainly by convection This results in the floor being the coolest place in the room with the mass of warm air at ceiling level The Whole Floor Acts as a Heat Source FEATURES amp BENEFITS The Speedfit Underfloor Heating System offers many benefits to the consumer These include Installation It is simple to install requiring the minimum of installation effort and little maintenance Comfort The system uses radiant heat the most comfortable form of heating giving an eve
31. ge of the main receiver or in poor reception areas allowing extended range Operating at a frequency of 868MHz the signal is repeated between receivers JGWWC or JGWRC Recess mounted requiring 35mm back box If needed can also be used in multiples allowing extreme range 230V powered and non networkable WIRELESS 2 ZONE RECEIVER Part No Description JGWRC WIRELESS 2 ZONE RECEIVER Mains powered and is capable of controlling 2 heating zones or heating and hot water zone using JG Speedfit Wireless thermostats Up to 32 units can be used with the wireless stats and has an operating distance of up to 100m Recess mounted requiring 35mm back box 230V powered and non networkable Part No Description JGWWC WIRELESS 8 ZONE WIRING CENTRE Mains powered and ideally suited to warm water underfloor heating as well as radiator systems or a combination of both using JG Speedfit Wireless Thermostats Operating at a frequency of 868MHZz central wiring allows for up to 8 zone actuators with an output for domestic hot water Internal software can distinguish between hot water underfloor heating and radiator signals 230V powered and non networkable Optional aerial is available to extend range if gt required JGAERIAL EXTERNAL AERIAL Part No Description JGAERIAL EXTERNAL AERIAL FOR USE WITH 8 ZONE WIRELESS CENTRE JGWWC JS Speedfit System Components MANIFOLDS STAINLE
32. ide a detailed drawing showing pipe layout flow rates suggested zone temperatures and advice on commissioning A member of our national team of Technical Support Engineers will be available to offer on site support during the installation process Technical Help Desk 01895 425333 The JG Speedfit Technical Advisory Service is available to assist and advise on all aspects of using the Speedfit System The service is available between 8 00am and 5 00pm Monday to Friday www speedfitUFH co uk JS Speedfit UNDERFLOOR Contents Low Voltage Network Control System A new Network Control System which is both easy to install and reliable with slimline and attractive components The basic system of Programmable Room Thermostats and Wiring Centre can be enhanced by a number of upgrade options PROGRAMMABLE ROOM THERMOSTATS AND WIRING CENTRE Two models of Programmable Room Thermostats Both offer 5 day 2 day or 7 day programming one has hot water timer facility An 8 zone Wiring Centre used to connect the wiring from thermostats actuator valve boiler and pump and manage the control of the network Page 10 TOUCH SCREEN THERMOSTAT OPTION A range of easy to use deluxe Touch Screen Programmable Room Thermostats make user manuals a thing of the past Page TOUCHPAD CENTRAL CONTROLLER OPTION Control up to 32 thermostats from one central location using easy touch screen control Pages 2 and 13
33. m in accordance with BSEN 264 STEP 3 The egg box sections of the panel clip firmly together to make a continuous seal Floor panels should not be used at the base of a manifold as pipes need to be closer together than the floor panels will allow Pipes around this area should be secured using pipe staples STEP 6 Once the pipe circuits have been installed and pressure tested the system should remain under pressure 6 bar in order to prevent the risk of any damage being caused to the pipe while the screed is being applied When applying the screed cover care should be taken to ensure that the screed is tightly compacted Installing of UFH Overlay System The JG UFH Overlay is a low profile System for new build or renovation projects JG Overlay is a lightweight insulated panel with high compressive strength intended for use on lightweight floor coverings e g laminate engineered wood and carpet Due to its ease of handling and cutting it is also suitable for larger areas and multiple room installations The installation uses 5mm pipe and 150mm centres for a highly responsive system STEP Planning the installation will save time later and make installation easier The main consideration is the amount of runs and the route those pipes will take from the manifold There are a number of parallel grooves at either end of the boards If more transit groove
34. m any PC without the need for specialist software to be installed dialling into the system via the internet using a password Used in conjunction with the JGUHI Wiring Centre to allow the user to take control of heating and hot water over the internet from any web browser Plug the Netmonitor into your home internet router and the built in software allows compete control of the system e Program up to 32 1 2 volt thermostats JGSTAT from any internet browser worldwide e Connect up to 6 volt free alarms such as home alarms and receive alarm indication on email e Control up to 6 appliances remotely via a web browser e Connect up to 6 remote temperature sensors to be used for alarm or monitoring www speedfitUFH co uk Temperature Alarm Receive low and high temperature alarms by email or SMS Outdoor Lighting Turn on or off your lighting either over the internet or SMS NET MONITOR GSM Part No Description JGNETMON2 With built in software NET MONITOR GSM Has the same functions as JGMONI but with an additional GSM facility This means the user can control the whole house heating system using text messaging on a mobile phone The heating can be turned up down on or off with a few simple text commands The unit also sends a text message alert as a confirmation A text message or email can also be sent to alert the owner if there is a fault on the system Recommended for holiday homes or for pe
35. n TOUCH SCREEN NETWORK ROOM THERMOSTAT Has all the features of the JGSTAT TS V3 plus the additional programme for domestic hot water The hot water feature can be set to give 4 different time control periods per day JGSTATPLUS TS V3 www speedfitUFH co uk screen display makes the user manual a thing of the past TWIN CHANNEL TOUCH SCREEN NETWORK ROOM THERMOSTAT Part No Description JGSTAT2 TS V3 TOUCH SCREEN TWIN CHANNEL NETWORK ROOM THERMOSTAT Brings the sophistication of touch screen technology at a similar cost to using dial thermostats by reducing the number of thermostats required in a property The 2 channel facility allows one thermostat to control 2 zones at the touch of the thermostat s screen This makes it perfect for a bedroom with ensuite or living room and dining room Zone uses the built in air sensor to control the room it is fitted in whilst zone 2 uses the remote sensor provided to control an adjacent room The 2 zones can be up to 20 metres away from each other The 2 channels significantly reduce installation time and cost by reducing the amount of wiring and associated labour while giving the user a simpler and less cluttered look JS Speedfit UNDERFLOOR TouchPad Option Control up to 32 zones TOUCHPAD NETWORK CONTROLLER The Touchpad can be used to control up to 32 zones Manifold Manifold 2 Manifold 3 Part No Description JGTOUCHPAD TFT TO
36. n depth as required by design or building regulations and to ensure that any downward heat loss does not exceed 10 watts per m 2 in accordance with BSEN 264 STEP 3 After establishing the area to be covered by the pipe circuit connect to the manifold and start the circuit If the circuit has to pass through other heated zones before reaching the zone it is intended to heat conduit may be required STEP 6 Once the pipe circuit has been installed and pressure tested the system should remain under pressure 6 bar in order to help prevent the risk of any damage to the pipe while the screed is being applied When applying the screed care should be taken to ensure the screed is tightly compacted around the pipe ensuring no voids are present e Recommended design flow temperature 50 C e Insulation depth as required by design or building regulations and to ensure that any downward heat loss does not exceed 10 watts per m in accordance with BSEN 1264 e The overall quality and thickness of a sand and cement screed should meet the requirements of BS8204 I www speedfitUFH co uk Wiky JS Speedfit UNDERFLOOR Installing of JG Floor Panel System Speedfit Floor Panels make a simple grid to ensure quick and easy pipe laying and also provide a precise guide for the pipe ensuring that minimum pipe bending radius is achieved Suitable for use with cement screed 4 1 mix pumped screed systems anhydrite etc fine or heavy concre
37. n distribution of warmth over the whole room Space The system is unobtrusive and space saving which means every square metre of floor and wall space can be utilised giving freedom of interior design Noise Compared to radiator systems the system is virtually silent running Health Dust is minimised reducing the problem of house dust mites Reduced numbers of hot surfaces and sharp edges minimise risk of burns or injury Efficiency Savings Underfloor Heating Systems are designed to operate at lower temperatures than radiator systems making them especially suitable for condensing boilers resulting in reduced energy consumption and lower heatloss from the building structure Control The system is easy to control and the small temperature difference between the floor and air means the system is virtually self regulating Environment Underfloor heating is suitable for use with the most energy efficient and environmentally friendly heating systems including condensing boilers solar power and heat pumps FLOOR FINISHES AND COVERING The Speedfit Underfloor Heating System is suitable for most floor finishes including ceramic tiles carpets vinyl and laminate The thermal resistance of floor covering will have a marked effect on the performance of the heating system Advice on the use of floor coverings and their effect on the performance of a system is available from our Technical Help Desk www speedfit
38. op of the joist STEP 6 Before fixing the floor to the joists it is recommended that a thin sheet of plastic is placed over the plates This will act as a slip membrane to cut down expansion noises as the plates heat up and rub against the bottom of the finished floor Dimensions 1200 x 350 x 50 mm Floor Coverings Tiles slate ceramic etc Approx Coverage Double Plates 2 Plates per Im2 box of 10 5m Materials Expanded Polystyrene BS EN 13163 Carpet Vinyl Approx Coverage Single Plates Compressive Strength 100 kPa 10 compression Laminate floors Recommended Design Temperature 60 C Maximum Heat Output Approx 70W m Conductivity 0 036 W mk Natural wood Heat Output Approx 50 60w m Recommended Flow Temperature 50 60 C Pipe Centres 200mm Maximum Circuit Length 100m Typical Coverage per Loop 15 20m Applications New Build or renovation single or multiple rooms www speedfitUFH co uk JS Speedfit UNDERFLOOR Energy Saver System THE SYSTEM Using standard manifold connections it is possible to develop a radiator valve capable of being controlled by a 240v Actuator head instead of a wax head it will be possible to control each radiator or groups of radiators by time and temperature instead of just time It will use conventional heating systems and be very easy to install requiring no extra work from the plumber Control wires need to be routed to the radiators but this
39. ople who work away from their property e Communicate by email or text message e Program up to 32 2 volt room thermostats JGSTAT from any internet browser worldwide e Connect up to 6 remote temperature sensors to be used for monitoring or alarm purposes e Connects up to 6 volt free alarms such as home alarms and receive indications on email or text message e Control up to 6 appliances remotely via web browsers or text messaging JS Speedfit UNDERFLOOR Mains Voltage Controls System The components in the mains voltage control systems have been designed to work with their respective wiring centres and are not intended to be used with other wiring centres e Easy to use e Easy to install Attractive slimline components Easy to use and install the John Guest Mains Voltage Controls offer simple but effective control of up to 8 zones The UH3 Wiring Centre is the hub of the system It works either in conjunction with our Touch Screen Time Clock and simple to use Dial Setback Thermostats or alternatively our Programmable Room Thermostats There is also the ability to use both types of thermostat in the same system The JGUH3 Wiring Centre has the capability for control of 8 heating zones and integrated connections for underfloor heating zones boiler hot water control Time Clock and the option of a radiator circuit Having all wiring to one central point makes the JGUH3 much easier to wire up than a
40. pre assembled and pre wired has integral ballvalves to allow for isolation from the primary system an adjustable blending valve to control the temperature of the water and a high quality 6 metre head circulating pump An anti vibration mounting bracket ensures silent operation Programmable Room Thermostat to give individual time and temperature with a simple menu for easy adjustment Control can be either 5 day 2 day or 7 day with up to 4 different time and temperature settings per day Speedfit Barrier Pipe that is lightweight and flexible with an inner barrier to prevent the ingress of air Manufactured and Kitemarked to BS7291 Class S INSTALLATION REQUIREMENTS The Heating Pack is designed to be used in solid floor applications The floor insulation material will normally need to be 50mm the pipe fixed to the insulation using floor clips A sand and cement screed of 65mm to 75mm laid on top In areas of high heatloss such as conservatories additional heating may be needed to achieve comfort levels A detailed Installation Guide is provided with each unit Please note Single Room Pack installations are not included as part of our Design and Technical Support Service For floor areas greater than 30 sq m Speedfit offer an Underfloor Heating System that can cater for any size of project Please contact the Technical Help Desk Tel 01895 425333 www speedfitUFH co uk JS Speedfit UNDERFLOOR Installation
41. r and Motorised Valve Network Touch Screen Range The JG Speedfit Touch Screen Range of de luxe Touch Screen Programmable Room Thermostats which can be used alongside other network products allowing remote TOUCH SCREEN NETWORK ROOM THERMOSTAT programming from options such as TouchPad Home PC the internet or mobile phone giving ultimate control over your heating system The intuitive easy to use touch TOUCH SCREEN NETWORK ROOM THERMOSTAT PLUS HOT WATER CONTROL Part No Description JGSTAT TS V3 TOUCH SCREEN NETWORK ROOM THERMOSTAT Can be used in 5 day 2 day mode or a 7 day mode to allow for different time settings for each day of the week giving total user flexibility The Thermostat is self learning To avoid unnecessary use of energy the thermostat can be set to optimum start delaying the heating start up to achieve the comfort level at the programmed time Includes a holiday function which reduces to a frost setting over the holiday period and reverts back to comfort level to coincide with your return The frost protection feature has an adjustable temperature setting The Thermostat has the facility to connect to either an air or floor probe JGPROBE NETWORK TOUCH SCREEN THERMOSTAT FEATURES e 4 Heating Levels e Optimum Start e Holiday Function e Keylock Function e Temperature Hold Function e Temperature Override e Frost Protection Part No Descriptio
42. r 10 minutes This testing combined with other relevant checks should reveal installation problems and is regarded as good plumbing practice e Pressurisation During Screed Laying amp Curing In accordance with BS 264 4 the system should be left under pressure at a minimum of 6 bar for the duration of the laying and curing of the screed Under NO circumstances should the UFH System be used to quicken the screed drying process e System Flushing As is usual practice for any plumbing installation flushing of the system prior to the use of JG Speedfit is recommended to remove any contaminants chemical residue from elsewhere in the system e Vermin Speedfit products should not be used in vermin infested areas e Frost Protection During the installation process it is important that pipe containing water be protected from frost John Guest Speedfit Limited Horton Road West Drayton Middlesex UB7 8JL England Tel 01895 449233 Fax 01895 420321 www speedfitUFH co uk www speedfit co uk Technical Help Desk 01895 425333 The company has a policy of continuous research and development and reserves the right to amend without notice the specification and design of all products illustrated in this catalogue John Guest Speedfit reserve the right to change the colour and shape of products Photographs are for illustration purposes only Subject to our Terms and Conditions of Sale available on request JG John Guest and
43. reasons Single Serpentine m VUUY Double Serpentine OVER EXISTING FLOORS An Underfloor Heating system that is installed over existing flooring which is suitable for both new build and renovation projects This means that current flooring does not require extensive alteration 1 Ve Triple Serpentine Counterflow with ball valves and drain filling valves JG manifolds are complete with pre fitted brackets and vibration isolation mounts STEP Fix the pre assembled manifold to the wall allowing enough height to accommodate the insulation and screed depth and also the pipe work and conduit elbows STEP 4 Run the pipework from the manifold to the room that is to be heated Ensure that if the pipework is passing through other rooms that conduit is used to prevent the pipework influencing the heat in those rooms Ensure the pipework is at least 75mm from the perimeter wall THINGS TO REMEMBER STEP 2 Using the supplied washer fit the JG control pack Isolation valves fitted to the inlet side of this unit will be useful in the event of needing to change a pump or blending unit STEP 5 The flow meters at the top of the manifold give a visual indication of the amount of water flowing through each circuit The amount of flow will depend on the length of circuit and the temperature drop required Generally the shorter the circuit the more restriction will be needed
44. s are needed then the grooves at the opposite ends can be cut off and used Where possible route pipes through rather than around walls and doorways to cut down on pipework congestion When lining up panels use a short length of pipe placed in the grooves to align them together STEP 4 Start laying the pipework by pressing it firmly into the grooves Where the pipework is connected to the manifold there will be a need to use plain insulation and pipe staples to accommodate the closer pipe centres DATA 25mm OVERLAY BOARD Dimensions 1250 x 600 x 25 mm Extruded Polystyrene XPS2 BS EN 13164 250 kPa 10 compression Materials Compressive Strength Conductivity 0 029 W mk Heat Output Approx 50 60w m Recommended Flow Temperature 50 60 C Pipe Centres 150mm Maximum Circuit Length 100m Typical Coverage per Loop 13 15m STEP 2 Plates need to be supported so that they sit level and make a good contact with the floor placed on them from above Maintaining this contact is essential in producing good heat transfer performance STEP 5 Where the pipe changes direction cut the foil in the return loops using a craft knife to prevent damage to the board This will ensure a tight fit for the pipework Laminate floors Natural wood Carpet viny STEP 3 After placing the boards and ensuring they are flat and level and the joints are butted up firmly tape the joints using
45. scription JGUFHEDGE 25 METRE ROLL Used with solid screeded floors Edge Strip is used around the edge of a room to provide an expansion gap for the solid floor as it heats up and cools down OVERLAY BOARD OVER FLOOR Part No Description Size JGUFHBOARD OVERLAY BOARD 1250MM X 600MM Grooved foil faced insulation panel for installing 5mm tubing over existing floor structures between battens or under floor between existing joints Heat output approx 50 60w m Recommended flow temperature 50 60 C Maximum circuit length 100m Typical cover per loop 13 15m Individual panel size 600 x 1250 x 25 mm Pipe spacing 150mm Approx 7 5m per box OVERLAY BOARD JOISTS AND BATTENED FLOORS Part No Description Size JGUFHBOARD2 OVERLAY BOARD 1250MM x 350MM Low profile system for new build or renovation projects Grooved foil faced insulation panel for installing 15mm tubing over existing floor structures to facilitate the use of Underfloor Heating Heat output approx 50 60w m Recommended flow temperature 50 60 C Maximum circuit length 100m Typical cover per loop 15 20m Individual panel size 350 x 1200 x 50 mm Approx 4m per box FLOOR PANELS Part No Description Size JGUFHTILE Floor Tile 1400MM X 800MM Supplied in packs of 12 Speedfit Floor Tiles have an Imm layer of insulation for support and additional thermal insulation SPREADER PLATES ACTUATOR VALVE Part No
46. te or polymer modified screeds STEP Edge insulation should be installed around the perimeter of the room to accommodate expansion that will occur when the screed is heated up It is good practice to seal the gap between the potential space between the expansion and the floor panel STEP 4 When a pumped liquid screed is to be used it is essential that all of the panel joints are made correctly and that no panels are allowed to simply butt up as this may allow the screed to flow below the panels causing them to rise up THINGS TO REMEMBER STEP 2 Floor panels should be fitted to a suitable flat sub base Extra insulation maybe required to match design or building regulations and to ensure that any downward heat loss does not exceed 10 Watts m2 in accordance with BS EN 1264 STEP 5 Starting from a manifold after establishing the area to be covered unroll the pipe and push firmly into the gap between the egg box sections Cover the designed area in the appropriate pattern and return the pipework to the manifold BS EN 1264 4 recommends that an expansion joint is constructed in stone and ceramic finished screeds for every 40m of floor area at a maximum length of 8m and an aspect ration of 2 1 An expansion joint is also required in long narrow areas such corridors etc e Insulation depth as required by design or building regulations and to ensure that any downward heat loss does not exceed 10 watts per