1. the previous step Note During time and date setting when the Adv or Bst buttons are held down the setting under adjustment will advance or decrease rapidly 7 2 Modifying the Date and Time of Day Normally the only change required will be to the time of day minutes in which case press and hold Time for 2 seconds during which the word HOLD will appear in the bottom left hand corner of the display After 2 seconds the display will show Press Time repeatedly until the minutes are shown flashing then use Adv or Bst to make the change Finally press Time briefly to get back to operating mode Other changes can be made in the same way but the Time button must be pressed to get back to operating mode There is no automatic exit from the date time setting mode 8 Programming the ON OFF Times FST17A only 8 1 Generating New Programmes The FST17A has four independent ON OFF periods available for programming each day The FST17A is a 7 day programmer with options of 7 days the same 24 hrs 5 2 days where the weekdays are the same and the 2 weekend days are the same and 7 individual days Press Prog and hold for approx 2 seconds Whilst holding the word HOLD will show in the top left hand corner of the display After 2 seconds the display will show Adv MODE y Mo Tu We Th Fr Sa Su Use Adv or Bst to change the day grouping MODE at th
2. Supp MASTER FUSED SPUR TIMESWITCH Cat No FST11A 24 Hour Cat No FST17A 7 Day Pog Ady Time Bst e e 5 Prog Ady Pe Time Ost PST 11A adc PST 17A mowo Installation amp Operating Instructions LIMITED 1 General Information Power Display back lit for 30 secs Reset button Override until ON LED when any button is pressed recessed next programme change and increments ses lt e programmes amp TimeDayMonthYear Poo pr programme tti SERRE i Sets date Bot We th Fr Sa oad and time Boost for 1 or 2 Fixing hole hours and decrements displayed value during time and Double pole programme switch FST 17A TIMERGUARD setting BS 1362 1 x 1 4 fuse Fig 1 FST17A FST11A Front Panel Contents 1 Supplymaster 2 3 5mm screws 1 Bag containing 2 screws cable blank and cable clamp 1 Instruction leaflet The FST11A 24 hour and FST17A 7 day are units which mount onto a BS 4662 flush mount single box or a BS 5733 surface mount single box 25mm deep in either case There is provision for a single front exit output cable with in built cable clamp The unit combines the facilities of a time switch and a double pole switched fused connection unit capable of being wired directly into a ring main The contacts are not volt free and there is no provision for a permanent ON or for earth continuity for which the back
3. ately In either case the display will initially show the full character set then display The only button which is now active is the time button Now proceed to setting the date time and then programming the ON and OFF times 7 Setting the Date and Time of Day 7 1 Initially Setting the Date and Time of Day Press the Time button and hold for approx 2 seconds Whilst holding the word HOLD will show bottom left in the display After the 2 seconds the default year 2009 will be diplayed Qa lt Use Adv increment or Bst decrement to change the display to the correct year The limit calendar year is 2050 Press the Time button and the month digits will flash Use Adv or Bst to set the month Press the Time button and the day digits will flash Use Adv or Bst to set the day Press the Time button and the hour digits will flash i Use Adv or Bst to set the hour 24 hour clock Press the Time button and the minute digits will flash 14 is shown as an example of the hours set in the previous step Use Adv or Bst to set the minutes Press the Time button briefly to exit date time entry and return to the operating mode The display will now read Showing correct time day of the week with the colon between the hours and minutes flashing 30 is shown as an example of the minutes set in
4. box termination can be used if required The unit has automatic daylight saving pre programmed in 2 Battery The unit has an in built non replaceable rechargeable battery which will keep the programmed times during power down situations for up to 4 weeks If the main switch is left in the OFF position for longer than this the display will go blank If the screen goes blank once power is restored and 4 hours elapsed to give a working battery charge reset must be pressed and times programmes re entered Switched live terminal load live connection Supply neutral terminal Supply live terminal Switched neutral terminal load neutral connection Fig 2 FST17A FST11A Rear Connections 3 Applications Energy consuming appliances such as immersion heaters and storage heaters up to 13A total loading can be supplied by the FST11A FST17A enabling users to make use of economy 7 If the user has other appliances which do not have a push button start such as washing machines dishwashers and tumble dryers these may also be controlled in the same way It can also be used to control lighting if a neutral is made available Lighting up to 2 5kw filament or 500W fluorescent can also be controlled 4 Installation The unit is designed to replace an existing single gang connection unit or fixed appliance outlet giving timed mains output protected by a BS 1362 fuse The unit is capabl
5. e bottom of the display This will step through the following programming options 24hr Mo Tu We Th Fr Sa Su 5 day Mo Tu We Th Fr followed automatically in programming by 2 day Sa Su Individual day Mo followed automatically in programming by each of the other days Once the desired day grouping is selected press Prog to move onto programming ON OFF times Display will show prog 1 ON and the hour digits flashing Adv Prog m JON eo wn ee on z le ES Bst Mo Tu We Th Fr example shown is for a 5 2 day program as the display shows Mo Tu We Th Fr Use Adv or Bst to set the hours and then Prog to change between hours and minutes Followed by Adv or Bst again to set the minutes Press Prog to change to program OFF time Use Adv or Bst to set the OFF time in the same way as for Prog 1 ON time Press Prog to scroll through program 2 ON program 2 OFF program 3 ON program 3 OFF program 4 ON program 4 OFF adding in times as required If you wish to omit programmes just leave dashes in that ON OFF location Press Prog to move to the next linked day grouping 2 day grouping follows the 5 day group automatically Set ON OFF times as before Once program 4 OFF has been set press Prog to exit program mode and return to operating mode If less than four programmes are required press Prog for approx 2 seconds afte
6. e of forming part of a ring main the terminals can accept 2 x 2 5mm sq cables or terminating a spur off the ring main The unit requires a minimum depth of 25mm within the box Ensure that the wiring is adequate for the load to be carried Connect incoming and outgoing cables to the relevant terminals Secure the unit to the back box with the 3 5mm screws provided forming the cables during installation to avoid entrapment and cable damage Use the earth terminal in the back box for earth continuity if required If installed into a metal back box earthing of the back box is required There is a removable cable blank to cover the front cable exit if this feature is not required If front exiting cable is required for instance to connect to a washing machine use the cable clamp supplied to secure the outgoing cable BS 1362 fuse Time switch LOUT SUPPLY APPLIANCE NIN N OUT Double pole switch Fig 3 Internal Schematic of FST17A FST11A 5 Fuse Use the appropriate BS 1362 fuse for the load The unit is supplied with a suitable 13A fuse 6 First Supply Connection and Reset The reset button is recessed to achieve a degree of tamper proofing and an implement such as a pen pencil or matchstick will be required to operate it From first connection to the supply allow the internal battery to charge up for 4 hours followed by pressing the reset button Otherwise if the battery is sufficiently well charged press the reset button immedi
7. ng mode The reset button can also be used whenever major changes of programmes are required 9 Programming the ON OFF Times FST11A only The FST11A is similar to the FST17A but only has one day group mode in programming Mo Tu We Th Fr Sa Su giving 24 hour operation Up to 4 programmes can be entered once only required in the same way as for the FST17A refer to section 8 10 Operating Mode 10 1 Override until Next Program Change In operating mode Adv advances the program to the next change If the output is OFF it will change the output to ON until the next programmed OFF period If the output is ON it will turn it OFF until the next programmed ON period 10 2 1 and 2 Hour Boost In operating mode pressing the Bst boost button once will give an output for one hour The display will show Lz 3 a lt If pushed twice then there will be a 2 hour output The display will show Qa lt If pushed 3 times the boost will be cancelled and output will return to the programmed state 3 a lt In operating mode the main switch is used to change between permanent OFF and timed There is no permanent ON setting 11 Specifications This product complies with LVD Directive 72 23 EEC EMC Directive 89 336 EEC and relevant clauses of the following standards BS EN 60730 7 2 1992 Particular requirements Timers and time switches BS1363 4 1995 Specification for 13A f
8. r helpline on 020 8450 0515 For assistance with the product please contact HELPLINE 020 8450 0515 or email helpline timeguard com LIMITED For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com A theben Group company 67 058 336 Iss 1
9. r the last programme entry to return to operating mode The display will show the correct day and time but the ON OFF indicator may not reflect the current programme accurately in which case press the Adv button to correct the indicator In the same way as for individual programmes days or groups of days can be omitted either by leaving dashes in all the locations for a day or a group of days or by leaving the programming mode before its completion where all further entries are to be dashes 8 2 Modifying or Adding Programmes Press Prog and hold for approx 2 seconds Whilst holding the word HOLD will appear in the top left hand corner of the display After 2 seconds the display will show MODE Mo Tu We Th Fr Sa Su Press Adv or Bst to select the day grouping which requires modifying or a new day grouping for an additional programme in which case proceed as in section 8 1 For modifications press Prog repeatedly to arrive at the programme time flashing requiring modification then use Adv or Bst to make the change Press Prog again repeatedly to arrive at a further time requiring modification and use Adv or Bst to make the change Proceed as before for further changes then press Prog for 2 seconds to return to operating mode unless you are at the end of the programme sequence in which case press Prog briefly There is no automatic exit to the operati
10. used connection units EN61000 6 3 2001 Emission Requirements for the RCLI Environment EN61000 6 1 2001 Immunity Requirements for the RCLI Environment Permissable loads 13A resistive 6A at 0 4 power factor inductive 10A filament lamps 500W fluorescent lighting including low energy lamps with or without power factor correction capacitors 4uF per 65W tube 1hp motor For other loads refer to technical service on 020 8450 0515 In applications such as use of economy seven electricity the full load will not usually be switched In the cases of a washing machine and a dish washer the load switched on will be water valves only and the load turned off will be negligible providing an appropriate time interval has been left to enable the machine to complete it s program Fuse protection BS 1362 as dictated by load 700 hours 4 weeks battery back up in case of supply failure double pole switch turned off or 13A fuse blow Operating ambient temperature 10 to 40 C Operating voltage 230VAC 4 ON OFF programmes per day independent for each day except when in day groups 5 Year Guarantee Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 5 years of the date of purchase please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge For years 2 to 5 or any difficulty in the first year telephone ou