1. 6 input common contact GND J2 ays 1A ZAND use the ACP main regulated 12 VDC power supply or a separate UL294 or ULC S318 ULC 319 listed 12 or 24 VDC power supply Power input is non polarized J10 J11 Request to PIB300 PIB301 output indicating when 1 enter input the access point exterior door handle is signal making a request to enter Connect to the ACP request to enter REQ TO input ENTER Request to l f J10 J11 enter common Connect only if the access point needs 2 contact GND t have request to enter function Output is pulled up to 5 VDC and can sink 50mA J40 for 340 311 General PIB300 PIB301 output indicating l Access 3 purpose alarm trouble is reported by the Access Point Point A 3 input signal Logic polarity is configurable TROUBLE General c J11 for Output is Pulled up to 5 VDC and can Access J10 J11 p rpose alami sink 50mA common Point B YU contact GND J10 J11 Door status PIB300 PIB301 output indicates the 5 input signal position of the access point portal open closed Connect only if the access control panel DOOR 1 2 needs to know the access point portal J10 J11 STATUS Door status state Logic polarity is configurable Output is pulled up to 3 6 VDC and can sink 50mA 6 Schlage PIB300 PIB301 user guide ACCESS CONTROL PANEL CONNECTION PIB300 301 Access panel Connector signal signal Description Explanation PIB300 PIB301 ou
2. PIB301 Daisy Chain Connect the PIB300 PIB301 to the access control panel ACP CAUTION Disconnect the ACP power and batteries while wiring the PIB300 PIB301 to the panel WARNING Because every access control panel is different always check the panel s instruction manual for appropriate interface wiring e For compliance with UL 294 product must be used with a UL294 Listed access control panel or unit For compliance with ULC S319 product must be used with a ULC S319 Listed access control panel or unit e Must be connected to external power using a UL294 listed power supply for UL installations and a power supply that complies with CAN ULC S318 or CAN ULC S319 for cUL installations The power supply must be capable of sourcing 250mA 12 or 24 VDC example Schlage PS902 PS904 PS906 Refer to Typical wiring to the access control panel on page 5 for how to connect DC power to the PIB300 PIB301 e Use shielded cables for the signal wiring between the PIB300 PIB301 and the ACP For maximum wire lengths and cable specifications sSee Cable wire specifications on page 5 for more information 4 Schlage PIB300 PIB301 user guide Cable wire specifications Application Part number AWG Description Max run leng DC power Belden 8760 or 18 2 conductor 1000 feet input equivalent 305 meters RS 485 Belden 9841 9842 or 24 2 or 4 conductor 4000 feet equivalent shielded 1219 meters PIB300 Alpha 1298C or 22 8 conductor s
3. 01 Install the lock See the installation guide that came with the lock or visit www schlage com support for more information Use proper wiring to the PIB300 PIB301 See Cable wire specifications on page 5 for more information Disconnect power to the lock and Access Control Panel ACP while connecting the PIB300 P1B301 Familiarize yourself with the information in this user guide Save this user guide for future reference Customer Service 1 877 671 7011 www allegion com us Handheld device HHD The Handheld Device HHD is used for programming and setup only The HHD is used to configure this device s links and outputs For information about the HHD see the SUS user guide PIB300 PIB301 installation Location e The PIB300 PIB301 should be located close to the access control panel wiring distance may be up to 500 feet 152 meters Wiring to the lock e Power wire for locks must be appropriately sized for the distance and voltage Communication wire should be suitable for use on RS 485 type networks The maximum length of the RS 485 wiring from the PIB300 PIB301 to lock 2 is 4000 feet 1219 meters e Wiring of locks requires one connector via the RS 485 connector J5 e Connections from lock to lock should be daisy chained see diagram below e The power supply is located at or near the PIB300 PIB301 for short wire runs or local to locks if located far from the panel RS485 PIB300
4. WII P516 097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Q Para el idioma espa ol navegue hacia www schlage com support Pour la portion frangaise veuillez consulter le site www schlage com support Overview Getting started Handheld device HAD sisiic st cenre eeo aaae eoar eea Ea seinen 4 STS TSR TET eT Belee Wiring to the lock Connect the PIB300 PIB301 to the access control panel ACP Cable wire specifications cccccccecsceceecceceneeeseeeceeaeeceaaeereneeeteaes Typical wiring to the access control pan l sisisi iiinis PIB300 PIB301 to ACP eTel 6 Complete the installation cccccccccceeeseceeeeeeeeeeeeecaeeeeeaeeseaeseeeaeeseaeeeseaeeeseaeeeeeaeesenetenas 8 Access point ACP connections to a RS 485 device address sse 8 Reset to factory detaullis 222 5 sii aechainin naan EN EA R NE 8 FCG statement icsi eaa a eae e aiaia edoi aea Een Sapa pa aio aN aaae 8 This product is compliant of UL 294 and ULC S319 standard This products compliance would be invalidated through the use of any add on expansion memory or other module that has not yet been evaluated for compatibility for use with this UL Listed product in accordance with the requirements of the Standards UL 294 and ULC S319 This product has been evaluated for ULC S319 Class I 2 Schlage PIB300 PIB301 user guide Overview The Schl
5. age Panel Interface Board PIB300 or PIB301 provides a means of connecting RS 485 based access point devices to a system requiring wiegand or clock and data protocol rather than direct RS 485 connection This manual describes the installation and operation of the PIB300 PIB301 Open architecture platform The Schlage PIB301 provides a means of connecting the FIPS 201 certified AD 301 to an access control system via Wiegand protocol Provides two way communication with locks via a RS 485 connection The PIB300 may connect up to two Schlage AD 300 locks or up to two RS 485 based legacy locks communicating with the RSI or VIP protocol may connect to an Access Control Panel ACP or reader interface board The PIB301 may connect up to two Schlage AD 301 locks to an ACP or reader interface board via wiegand protocol Legacy and AD 300 locks may not both be present on the PIB300 s RS 485 connection The trouble signal output will change state when the Anti Tamper Switch ATS signals that the PIB300 PIB301 enclosure lid is open or if an access point device indicates trouble status Before installing a Schlage AD Series system read all documentation for all products in the installation Wiegand or Access Clock amp Data Control PIB300 ontro H forPIB300 4 RS485 Panel Wiegand only PIB301 for PIB301 Getting started The following is an overview of the steps required for setting up the PIB300 PIB3
6. d up to 3 6 VDC and can sink 50mA J8 J7 Common signal ground for the EXIT GND Signal ground REQ DOOR STAT TROUBLE DATA DU and CLK D1 signals Complete the installation After all required connections have been made connect the power and ACP standby batteries to the panel Access point ACP connections to a RS 485 device address The PIB300 PIB301 access point to ACP connections are each associated with a RS 485 device address This association is set using the Schlage utility software SUS Please see the SUS user manual for further information The PIB300 PIB301 defaults to access point 1 connections associated with RS 485 device address 0x00 and access point 2 connections associated with RS 485 device address 0x01 Reset to factory defaults All configuration information will be deleted and the PIB300 PIB301 will be reset to factory defaults 1 Remove the main cover 2 Press and hold both link buttons for over 3 seconds 3 Release both link buttons The PIB300 PIB301 will blink the red lights beside each link button while configuration reset takes place 4 The two green lights beside the link buttons will blink 3 times when the reset is complete 5 Replace the main cover FCC statements Allegion agency statements Compliance statement Part 15 19 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interfer
7. ence and 2 This device must accept any interference received including interference that may cause undesired operation Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC interference statement Part 15 105 b This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help RF exposure statement To comply with FCC IC RF exposure requirements for mob
8. hielded 500 feet PIB301 to equivalent 152 meters ACP Typical wiring to the access control panel Do not connect cable shields at PIB300 Strike Input Strike Input Gnd D1 CLK O eS G CO J2 LINK1 sO J38 edoa J5 GND TB RB TA LINK2 RA fo lor J11 b o ale o elo oka 969988699 Gnd RS485 connection to daisy chained access point 1 Req to Enter Req to Enter Gnd Trouble Trouble Gnd Status Status Gnd Req to Exit Req to Exit Gnd Access Control Panel Notes Only AP1 is shown connected AP2 should be connected the same way Unsupervised ground switched inputs to panel shown Some Access Control Panels require supervised inputs and or dry contact isolated inputs The optional Schlage RLBD is available for these applications Run shielded cables through grounded conduit and access point 2 P1IB300 PIB301 to ACP connection ACCESS CONTROL PANEL CONNECTION PIB300 301 Access panel Connector Signal Signal Description Explanation PIB300 PIB301 inputs for 12 or 24 VDC power If the access control panel ACP reader power outputs do not source enough current for the PIB300 PIB301
9. ile transmitting devices this transmitter should only be used or installed at locations where there is at least 20 cm separation distance between the antenna and all persons Section 7 1 5 of RSS GEN Operation is subject to the following two conditions Aub l 1 This device may not cause interference and Allegion 2014 2 This device must accept any interference wru sas eee including interference that may cause ALLEGION i undesired operation of the device K 11 000 d m 5 500 d FRONT FRONT 8 500 S000 BEGINNING SHEET FOLDED SHEET Additional Notes Revision Description 1 Booklet format center stitched a Ba c ov e fF L A Material Edited By Approved By Release Date White Paper P Bockelman 03 28 14 Notes Title ler ann User Guide AD Series PIB300 printe ac tolerance 13 Creation Date Number Revision see sheet 2 for artwork 12 21 2009 P516 097 F printed in country may vary drawings not to scale Created By Activity P Bockelman 3899 Hancock Expwy Software InDesign CS6 Security CO 80911 Allegion 2014
10. tput indicating when 5 J10 J11 Request to exit the access point interior door handle is 7 input making a request to exit ee Connect to the access control panel Point A REQ TO EXIT request to exit input J41 for J10 J11 Request to Connect only if the access point needs S 8 exit common fto have request to exit function Access contact GND Point B Output is pulled up to 5 VDC and can sink 50mA RESERVED 5 VDC power supply pin J11 9 Whe F VDE for the RLBD dry contact relay board Strike input monitors the access panel J8 J7 See Open strike relay 1 seas Connect the strike signal to the normally contact open or normally closed terminal of the strike relay The active signal state of STRIKE the PIB300 PIB301 is programmable INPUT with the HHD oa me atl Connect the ground signal to the 2 daa iag common terminal of the strike relay J8 for Connect only if the access point needs Access to be unlocked door or raised gate Point A J8 J7 D1 CLK Clock or PIB300 PIB301 outputs used to present 4 3 data 1 output card data to the ACP or Access For an access point with a magnetic Point B reader will present clock and data signals to the access control panel For an access point with a wiegand or J8 J7 DATA Data or proximity reader will present Data1 and 4 data 0 input Data0 signals to the ACP If initial hookup fails to operate switch wires at these terminals Output is pulle