Home
Instruction Manual Inverter Control Pump
Contents
1. In OL try starting the pump until water is available every 10 minutes e To force the pump to run press STOP and then RUN to resume the operation 6 2 4 EEP 1 EEP 2 display Irregular memory a Reset and then press PROG b If the same problem appears call for service 6 2 5 PF01 PF02 PF03 PF04 display for irregular drive a Reset to run the operation once more after power off b If the same message appears again call for service 6 3 Remarks a For safe service be sure to turn off the pump b When the red warning light in the variator goes on be sure to keep your hands off the parts and the circuit board for electric shock c In case of failure of the internal parts do not try to replace or repair them yourself or this office would not be responsible for consequences 3 7 Wiring diagram 7 1 Single phase 220V variator 3 phase 1 phase power power NFB NFB In case of 3 phase 220V Connect any 2 wires FAN T S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Control box Variator SFSWCOM IN 1 4 wiv IU a AGN r7 r7 N Se Red White Pressure Pressure switch sensor
2. arising from installation use or any other causes There are no express or implied warranties including merchantability or fitness for a particular purpose which extend beyond those warranties described or referred to above Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of an implied warranty therefore the limitations or exclusions herein may not apply This warranty sets forth specific legal rights and obligations however additional rights may exist which may vary from state to state Supersedes all previous publications WALRUS PUMP CO LTD WALRUS Web www walruspump com CC70D0008DO00EWORO1 A WALRUS iG Series Inverter Control Pump Instruction Manual mm 4 ISO 9001 Certified Walrus Pump Co Ltd 1 Preface We appreciate your purchase of this Inverter Control Pump of variable frequency and constant pressure For correct installation and use of this product be sure to read this user s manual before proceeding with the installation for the sake of sound performance and safety Please keep this manual all the time for future reference in maintenance service and repairs When you purchase the product be sure that it has undergone strict test and has been duly packed and handled with consideration of all factors Before installation be aware of the following and all irregularities shall be notified
3. recommendable to use AUTO for regular operations as PSW is available as replacement 6 Troubleshooting 6 1 Pump motor Before proceeding with this step turn the power off 6 1 1 The motor does not run a Check for correct voltage b Check for water supply c Check for stuck pump d When working on PSW be sure to check if the silver contact of the pressure switch is on if not the silver contact may go oxidized and cleaning would become necessary e When the water temperature goes high the thermostat switch would go off Once the water is cooled the operation would be resumed automatically f If the operation fails to go on call service 6 1 2 When the motor keeps running when with the water supply cut a Check if the faucet is tightened and whether the toilet and piping is leaking b Open the check valve to check for sticking or leakage c Low power supply 6 2 Variator 6 2 1 SF display No operation The safety terminal is OFF a Check the wiring protection for interruption b If no SF terminal is in use be sure to have the SF terminal be connected with COM terminal 6 2 2 OPE1 display Warning on erroneous setting a Reset to run the operation once more after power off b If the same message appears again call for service 6 2 3 OL display Abnormal display with water and power off a Check for cut power supply b Check if the pressure sensor has signals c Check the pump d
4. 5 1 1 Check the variator and the wiring diagram The single phase variator runs on 220V 10 In case of 3 phase 220V 10 just connect any 2 of the wires A 3 phase variator runs at 3 phase 220V 10 or 380V 10 5 1 2 Remove the water stop and fill the pump compartment before tightening the water stop 5 1 3 Try to check if the wind hood runs in the same direction that of the steering nameplate 5 2 When using auto control 5 2 1 Press AUTO and then press PROG to switch the computer to run on VARIABLE AUTO 5 2 2 Press A and V for a desired pressure and then press PROG to complete the setting 5 2 3 To change the pressure setting just repeat 5 2 2 5 3 Pressure switch 5 3 1 Press PSW at this time PSW of the upper left goes on Press PROG to have the computer switch to PRESSURE SWITCH for pressure setting 5 3 2 To resume AUTO press AUTO and PSW of the upper left goes off Press PROG to resume AUTO 5 4 Remarks 5 4 1 Failure to press PROG after pressing SET or adjusting pressure figures the function that had been set earlier will be resumed in case of blackout 5 4 2 After the power goes off when there is no water the display will show OL Wait 10 minutes before the motor restarts on its own To force the pump to run press STOP and then RUN to resume the operation 5 4 3 PSW does not work when the pump runs on AUTO AUTO does not work when the pump runs on PSW 5 4 4 It is
5. Limited Warranty Products manufactured by Walrus Pumps Co Walrus are warranted to the first user only to be free of defects in material and workmanship for a period of 12 months from date of installation but no more than 24 months from date of shipment Walrus liability under this warranty shall be limited to repairing or replacing at our election without charge FOB Walrus distribution center or authorized service agent Walrus will not be liable for any cost of removal installation transportation or any other charges that may arise in connection with warranty claim The warranty period commences on the date of original purchase of the equipment Proof of purchase and installation date failure date and supporting installation data must be provided when claiming repairs under warranty This warranty is subject to due compliance by the original purchaser with all directions and conditions set out in the installation and operating instructions Failure to comply with these instructions damage or breakdown caused by fair wear and tear negligence misuse incorrect installation inappropriate chemicals or additives in the water inadequate protection against freezing rain or other adverse weather conditions corrosive or abrasive water lightning or high voltage spikes or through unauthorized persons attempting repairs are not covered under warranty Walrus will not be liable for any incidental or consequential damages losses or expenses
6. ites free of vibration and major surges d Installation sites for easy maintenance and service 3 2 Installation remarks a To install the pump keep out impurities It s important to keep plastic pipes free of PVC glue metal dregs that may jam the wheels b Add NFB to input power supply as protection to the variator and the motor c Is symbol for grounding terminal Be sure to ground it for electric shocks d Be sure of the power supply of single phase 220V 3 phase 220V and 3 phase 380V e Never run the product without water and keep water temperature at below 40 C and do not user other liquids than water f A metallic pipe should be used as the outlet pipe to avoid breakage due to high pressure or abnormal liquid temperature 4 Console 4 1 RUN The constant pressure indicator that goes on during operation at constant pressure 4 2 psw The pressure difference indicator that goes on during operation with pressure difference he 4 7 4 TPH2T 4TIC Standard model Single phase 220V variator Control box 3 phase 1 phase power power NFB Variator In case of 3 phase 220V Connect any 2 wires FAN Red Pressure sensor 7 5 Remarks White a To avoid frequent off of the thermostat in areas of hot water remove the thermostat switch and have SF be connected with COM and keep water temperature at bel
7. ow 60 C b To add a water level switch connect the water level switch with the thermostat switch 7 2 3 phase variator FAN T S 3 phase power NFB o 220V o 380V Control box Variator SFSWCOM IN 1 Cc LiL2L3 3 4 2 LiL 7 3 3 phase 5HP variator FAN T S Red White Pressure Pressure switch sensor Control box 3 phase power Variator gt gt SFSWICOM IN gt 1 2 Lilacs 3 4 W VIU S5IL1L2L3 Red White Pressure Pressure switch sensor 4 3 SET ER Digital display of pressure setting Maximum pressure set per model and pressures required 4 4 ACTUAL cd Digital display of actual pressure 4 5 gt 2 digit display of pressure up between 00 99 4 6 lt 2 digit display of down between 00 99 4 7 pressure Function memory key for all functions and data 4 8 STOP The key to stop the pump 4 9 The key to start the pump 4 10 AUTO Auto key to run the pump on constant pressure when RUN goes on 4 11 The key to run the pump with pressure difference when RUN and PSW go on at the same time 5 Operation 5 1 Power on
8. to the dealer of this office for solutions a Damage of deformation during transportation b Complete parts when you unpack the product c Do the specifications of the product match the nameplate Pressure and HP d Normal keys on the keyboard e ISO label 2 Functions and features a Variable frequency and constant pressure control this product Once the constant pressure is set its service pressure will never exceed the preset one This is not the case for pressure difference type b Smooth start and stop low noise minimum vibration and no water hammer c No water auto break as protection of the motor with auto start until water supply is resumed d Auto water leakage sensor with pressure compensation e In case of irregular variable frequency and constant pressure the product is switched as a pressure difference type product thus assuring water supply all the time TPH2T 4T IC Standard model without pressure difference function f Compact easy installation and operation g Power supply of single phases 220V 3 phase 220V and 3 phase 380V 3 Installation and remarks 3 1 Site of installation As the environment of the site of installation mainly determines service life of the product the follow sites are recommended for installation a Ambient temperature 49 C 40 C with good ventilation and dryness b Try not to install it outdoors to avoid sunshine and rain c Installation s
Download Pdf Manuals
Related Search
Related Contents
Sicurezza - Città di Torino manual instrucciones crono 8gm-15 gm y 20 gm ŠKODA Superb Manual de Instruções - Media Portal qui - FileMaker TAFCO WINDOWS NU2-256S-I Instructions / Assembly Electrolux EOB3400AOW 取扱説明書 ダイヤコア震動ドリル Aluratek AHDURS250F250 User's Manual Manuel - Evolio Copyright © All rights reserved.