SICOM3024SM Industrial Ethernet Switch User`s Manual

image

Contents

1. 9 5mm POE AC power AC power SFP RS232 console power input input ON module ports al terminal A N 7 N f i y N 7 G IN N fa a a n bccaolo cen o B e I9 e le 3 o al nu E E 2 3 E E 4 POW oo l oo j i 000 TT fU TORIO 0000000 TIR TUR TRITT TUR TIR TIT TCR 2 ERN l j i fi TIT TIT TERRI M0000 TRU TRITT TRITT CORRADO TRU TIT TCR 4 RJ45 ports Figure 3 4 Back panel of SICOM3024SM SFP Gigabit Optical Fiber TP interface SICOM3024SM offers four pairs of redundant 1000Base LX full duplex single mode or multi mode optical fiber interface LC connector or 1000Base TX RJ45 interface RJ45 connector Port numbers are G1 G2 G3and G4 Optical fiber interface should be used in pairs TX and RX are a pair TX interface is the transmitting end connected to the receiving end RX of the optical fiber interface of another remote switch RX is the receiving end connected to the transmitting end TX of the same optical fiber interface of the same remote switch Four pairs of redundant 1000Base LX optical fiber interface can be used to form an optical fiber r
2. Static FOB Multicast transmit unknown Enable Help i Static FDE Multicast List Static FDB Multicast List Configuration O11ECD1 TOOCF l 1 4093 Port List Modulel FE3 a Modulel FE4 Madulel FE5 Madule2 FE4 Figure 7 24 Static Multicast filling sample 44 v KYI LAND Chapter 7 WEB Management Static FOB Multicast transmit unknown Enable Static FOB Multicast List D AE CD 17 DD CF Module FEY Modulet FE Static FOB Multicast List Configuration 1 4093 Port List ModulelfFEl a ModulelFE2 Modulel FE3 ModulelFE6 Figure 7 25 Static Multicast configure successfully 7 4 6 IGMP snooping Click the IGMP Snooping in the left menu and enter the page as Figure 7 26 enable IGMP SNOOPING and auto query click Apply to finish configuration Click IGMP Snooping in the left menu again to show configuration result as Figure 7 27 Note Before enabling IGMP Snooping static multicasting address table must be closed firstly The switch only support 256 pieces of multicast address never over this range during the operation 45 Y SICOM3024SM Industrial Ethernet Switch User Manual KY LAND IGMP Snooping Disable Disable de IGMP Member List Figure 7 26 IGMP SNOOPING IGMP Snooping Enable Enable di IGMP Member List 01 00 SE 7F FF FA i
3. Upload amp Download Configuration Figure 7 13 Upload sample 7 4 Device Advanced Configuration The advanced configurations include port traffic flow VLAN port mirroring port trunking static multicasting address IGMP Snooping SNMP Alarm ACL RSTP DT Ring POE QoS and other settings etc 38 v KYI LAND Chapter 7 WEB Management 7 4 1 Port Traffic Flow Click the Port Flow in the left menu and enter the page as Figure 7 14 where you can configure the RX TX speed of each port as the range of 128K 256K 512K IM 2M 10M 50M 100M for 100Mbps port and 100M 500M 1000M for Gigabit port Click Apply to finish configuration feats me Pewee Dweus rs O emi S Mbps e eere Modules Disable Figure 7 14 Port Traffic Flow 7 4 2 VLAN Click the VLAN in the left menu and enter the page as Figure 7 15 and select based on 802 1Q as VLAN mode click Add to enter into the page as Figure 7 16 Enter VLAN name ID VLANI is the default select VLAN member tag or untag click Apply to finish configuration Note in the default state VLAN ID is 1 the range of ID no is from 2 to 4093 39 Y SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 40 Configure VLAH Ingress WLAN Filter Nonmenber Drop le Untagged Port VLAN List Figure 7 15 Add VLAN Add VLAH VLA
4. The system comes with high powered CPU processor Lay 2 switching of high performance Security design at the level of industry Offer 24 FE ports s Support VLAN IGMP Snooping Port Mirroring Port Trunk e Broadcasting storm control DT Ring DT Ring RSTP redundancy protect mechanism Used widely in various industry fields Kyland Technology Co LTD All Rights Reserved Figure 7 2 Main Page 7 2 Device Status Display The menu of device status includes three submenus Basic Information Port state Port Traffic Flow 7 2 1 Basic Info Click Basic info and enter the interface as shown in Figure 7 3 which displays MAC address IP address software version hardware version etc Basic Info MAC Address D0 1 E CD 1 7 70 05 IP Address g2 158 0 2 Figure 7 3 Basic Info 32 v KYI LAND Chapter 7 WEB Management 7 2 2 Port State Click Port State and enter the page as shown in Figure 7 4 which displays the link state port speed full half duplex and flow control state etc Port Status Macdule1 Macdule1 Macdule1 Madule1 Modulet Madule1 Module Module Module Module Module Module Module 3 Module 3s Module 3 Madule3 bodule3 Modules FE FE F F FE FE FE FE FE FE FE F F F F F F FE Enable Down Enee Down edi cali ei Sal Cali cdi enable Down E pc E casi EUN EE er ed
5. 50 GANZ POR Commour atom AAA battens usce eaten ete denel ru dete EUER aude ens 53 PANS QOS CONTA OU eg ii A AA A at desea dere aia M 54 TALA Otierconlisuralno irish lit 57 TAS RMON Conta nta enm susto tu secs te aar 58 Device Manage mieit AAA A A A A tastacteadttaltnes 61 7 5 1 Restore ii ili i Mi iE EE 61 LIZ ET PR 61 o Ba O 7 Load Default Appendix A Twisted pair and Pin Distribution ccce Lc rece eere eee eee eee e e e eee ettet ettet teet eese esas Appendix B Cable Type and Specifications nere nananana nane ne nerenenenerereeeeeerereserenezeenen Appendix C Glossary Appendix D FTP Application for Switch Software Update c ceeeeeeee eee v AY LAND Chapter 1 System Overview Chapter 1 System Overview 1 1 Product Overview SICOM3024SM is a high performance Gigabit industrial Ethernet switch specially designed by KYLAND Technology CO LTD for industrial applications The ports of SICOM3024SM support POE function IEEE802 3af the standard of POE divides power supply system into PSE Power Sourcing Equipment and PD Powered Device Its high performance switch engine solid and closed case design high efficient single ribbed casing for heat dissipation without fans over current over voltage and EMC protection at power input side and excellent EMC prot
6. E E Full duplex 1 1 1 E E E E E E TX 2 TX 3 TX 4 TX 5 TX B TX TX 2 TX 3 TX 4 TX 5 TX B TX FX 2 FX 3 FX 4 FX 5 FX B FX Figure 7 4 Port State 7 2 3 Port Traffic Flow Click Port Flow and enter the page as shown in Figure 7 5 which displays the port flow statistics of each port 33 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Port Statistics Mosel FE TX Up 668540 1772 amesa O wa 0 Moser FER T Dawn 8 8 8 9 a Wu FES TX Dam 8 9 8 9 9 CEE X pww 8 8 9 a Wu FES TX Dawn 9 89 9 9 women ee TX Dawn 0 8 8 9 8 CE TX Dawn 8 8 8 9 9 Weue Fr Tx pom 9 8 9 Jo osea Fes Tx am 0 9 8 9 e Weun Fe TX pwm 8 8 9 a Mose FES TX Dawn 9 8 9 9 wem res n up mo ese sso ex Moses re fX own 9 9 9 8 Mose FER PX own 0 o o 9 o wes Fes FX Down o 9 o o o Moses re FX Down 0 o o 9 o Moses FES PX pwm 0 9 9 o o Moses ES FX ow 0 o 0 o o Figure 7 5 Port Flow 7 3 Device Basic Configuration In the menu of Device Basic Configuration there are functions to configure IP address device name port to change password query software version and upgrade software upload and download configuration etc 7 3 1 Configure IP Address Click the IP addres
7. The network can re configure within 50ms when failure occurs Figure 6 1 SICOM3024SM build the redundancy fiber ring 6 2 System configure SICOM3024SM is a integrative industrial Ethernet switch offering the system main board power supply backplane 4 self adaptive SFP interfaces of 100 1000M 4 29 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND expansion slots which can connect to plug and play module of 100M Each of the four 100M modules plug and play offer 6 ports which can be RJ45 ports of 10Base T 100Base TX with POE function or 100M single mode multimode fiber ports The power supply for SICOM3024SM should be DC24V DC48V DC110V AC220V DC220V Detailed configuration showing as table 6 1 Table 6 1 SICOM3024 configure table SICOM3024SM 4GX 4 expansion slots up to 24 x 100M ports battery feed input SM3 6S M 6 x 100Base FX SM MM fiber ports FC SC ST SM3 5S M 1TX 5x 100Base FX SM MM fiber ports FC SC ST 1x 10Base T 100Base TX RJ45 port SM3 4S M 2TX 4 x 100Base FX SM MM fiber ports FC SC ST 2 x 10Base T 100Base TX RJ45 ports SM3 3S M 3TX 3 x 100Base FX SM MM fiber ports FC SC ST 3 x 10Base T 100Base TX RJ45 ports SM3 2S M 4 TX 2 x 100Base FX SM MM fiber ports FC SC ST 4 x 10Base T 100Base TX RJ45 ports SM3 S M STX 1 x 100Base FX SM MM fiber port FC SC ST 5 x 10Base T 100Base TX RJ45 ports SM3 6TX 6 x 10Base T 100Base TX RJ45 ports SM3 6TX PSE 24V 6 x 10Ba
8. Or Moaea Fee Di Enable m ii a gra ore eue res vx fabio m ivi a gori pra eue res 1 fo ii ml a al xD Wes rer PX ffnabie al mor aa ore Moaes rez pao Porca mor gra a Moaes res P Enabie m fosco mor gere a Woaues FE x ao osa mr gra ra Moaes res px ao forca gra a TOGO ra A eee rl Figure 7 8 Port Configuration 7 3 4 Change Password Click the Change Password in the left menu and enter the page as Figure 7 9 enter old password and new password click Apply to take effect Jm Change Password Figure 7 9 Change Password 7 3 5 Upgrade Software 36 Click the Upgrade Software in the left menu and enter the page as Figure 7 10 For v KYI LAND Chapter 7 WEB Management detailed upgrading instructions please refer to the Appendix D O Enter the main WEB page click upgrading bar of basic configuration in navigation bar to enter into the upgrading page as shown in the following Figure Software Update ea sicomi024sm bin Figure 7 10 Upgrade Software Configure IP address user name password and software name of the FTP server click Apply button and record upgraded software ID As figure 7 10 the address of FTP server and IP address of switch should be in the same network segment Wait for upgrading and see the successful message Click Software Version in navigation bar set the software ID as start
9. check version set updated software ID as startup version as FigureD 7 Software Version FigureD 7 inquire Software Version 5 Click Restart under equipment management in navigation bar as Figure D 8 Reboot Figure D 8 reboot 71 V SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 6 Wait for 30 seconds start Web management system click on navigation bar to check equipment basic information software version sure about the update successfully As Figure D 9 Basic Info Figure D 9 basic information Update is finish 72
10. developed by Kyland It determines the state of ring amp port and ensures the redundant network won t form ring by inspecting the ring port state and less protocol messages It make sure the Ethernet redundant ring is fast and reliable to meet the high requirements of industrial communications DT Ring KYLAND Chapter 2 Performance Specifications Based on DT Ring DT Ring realizes standby between two rings and determines the ring and port state according to the standby device ID ensuring the redundant network does not form ring RSTP RSTP and STP offer network redundancy protection for the switch network RSTP can realize all the functions of STP and additional reduce the delay from block to forward resuming the network ASAP ACL SICOM3024SM offers ACL Access Control List function to define the access rules by using the protocols of source or object MAC addresses It can limit the network traffic increases the networking performance and control the communication flow Alarm Output Alarm is significant when it is used for real time transmission of device alarm output SICOM3024SM offers the alarming functions for port and ring Through management software all the alarming functions can be enabled or disabled The alarming information is shown from management interface SNMP SNMP Simple Network Management Protocol offers frame structure for low level network management SNMP protocol is used so widely that many kind
11. 1s 20 Forward Delay Time From 4 to 30 The default is 15 and Message age inc default or compulsion Additionally you can configure protocol state of each port priority path cost etc After configuration click 49 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 7 4 11 50 apply Note RSTP can not be used together with DT Ring Configure RSTP Configure Protocol ESTP s2T688 32788 w 65535 Configure Port Figure 7 33 RSTP configuration DT Ring Configuration Click the DT Ring in the left menu and enter the page as Figure 7 34 to configure redundant ring based on port or VLAN Click Add to enter page such as Figure 7 35 and Figure 7 36 Enter domain ID No ID 1 32 domain name set master or slave station select ring port Module 1 4 FE1 FE6 0 GE1 GE4 Additionally there is DT Ring in this device you can select this function and enable it select standby port and click Apply Click ring name and see ring state in the DT Ring page as Figure 7 37 see it as Figure 7 36 A Attention Fach ring only support one master the others are slaves The devices in one ring have the same ring ID The port with different ID No can t be in one ring network Redundant ring support DT Ring You can only configure ring based on port or VLAN One of ports on the master is in block state the other is in transfer state If t
12. 4SM case is shown in Figure 3 2 Its contour dimension is 88 mm X 482 6 mm X 245 mm height X width X thickness Figure 3 2 outline drawing of SICOM3024SM AN Warning The shell of this switch is a part of the heat dissipation system of the unit It may get hot during working so never touch the shell when the equipment is working to avoid burning 3 2 2 Front Panel SICOM3024SM Industrial Ethernet switch front panel is show as Figure 3 3 12 KYLAND Chapter 3 Hardware Structure NS I COM3024SM Industrial Ethernet Switch KYLAND slot1 slot2 slot3 slot4 operation indicators indicators indicator for Gigabit for 100M ports ports Figure 3 3 Front panel of SICOM3024SM 3 2 3 Back panel SICOM3024SM Industrial Ethernet switch front panel is show as Figure 3 4
13. Bthortn Figure 7 27 IGMP Snooping configure successfully 7 4 7 SNMP Configuration 46 Click the SNMP Configuration in the left menu and enter the page as Figure 7 28 enable SNMP and set read read amp write name enter TRAP server IP address TRAP port no and click Apply to finish configuration By SNMP configuration the device only receive the message which name is line with the setting name of read and read amp write By setting the Trap IP address device can selectively transmit TRAP message to those IP addresses in the Trap IP address table By setting the Trap port number EMS management server just receives TRAP messages on those port numbers KYLAND Chapter 7 WEB Management public 3 16 Configure Management Station Configure Trap 162 1 B5535 Figure 7 28 SNMP configuration 7 4 8 Alarm configuration Click the Port Alarm in the left menu and enter the page as Figure 7 29 to configure port and ring alarm click Apply to take it effect 47 Y SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Configure Alarm Port Alarm Configuration Enable Enable Disable Disable Disable Disable Disable Disable Disable Disable Disable p Disable F FE4 Disable FEE Ring Alarm Configuration an ES Figure 7 29 Ring Alarm Configuration 7 4 9 ACL Configuration Click the ACL Configuratio
14. I X auto connection 100Base FX full duplex SM MM redundant fiber connector Recovery time 50ms increase the system reliability Broadcast storm control IEEE802 3 802 U 802 3X store and forward IGMP Snooping Port mirroring Port trunking DT Ring DT Ring RSTP protocols etc VLAN Tag ACL function Alarm function SNMP protocol POE function 802 1P IP TOS DSCP priority Transparent transmission of VLAN Tag packets FTP based online software upgrade easy for equipment management and renewal 2 Industrial Power Design Provide industrial power input DC24V DC48V DC110V AC220V DC220V Power input over current over voltage protection and EMC 3 Rugged Design Single Ribbed heat removal design fanless operation at 40 C to 75 C Solid and closed case design IP40 can be used in harsh environment KYLAND Chapter 1 System Overview 1 3 Packing list and unpacking check 1 Packing list see the packing list 2 Unpacking check Before opening the case place it stably pay attention to the direction of the packing case and ensure its right side is facing upward so as to prevent SICOM3024SM from falling apart after opening the case If a hard object is used to unclench the case do not overly extend the hard object into the case to avoid damage of the equipments inside the case After opening the case check the amount of SICOM3024SM equipments including main unit of SICOM3024SM parts of equipment user s manu
15. N Name n ane VLAN ID 2 were oni x TI a a a Ca Ca Ca Ca Figure 7 16 VLAN Configuration Configure VLAH Ingress WYLAN Filter Nonmember Drop Untagged Port VLAN List default 1 Figure 7 17 VLAN configuration successfully KYLAND Chapter 7 WEB Management Untagged Port VLAH List Module FEA Module FE Module FES Module FE4 Module1 FES Module FEB Module F E1 Module FES Module ZF E3 Module 2 FE4 Module 2 FES Modules FER Module 3FE1 Module SPE Module WFES hModules FE4 Figure 7 18 Untagged Port VLAN List 7 4 3 Port Mirroring Click the Port Mirroring in the left menu and enter the page as Figure 7 19 select mirroring port from range of Modulel 4 FE1 FE6 Module0 GE1 GE4 and mirrored port from the range of TX RX TX amp RX click Apply to finish configuration Port Mirroring Disable iu Modulel FEl Nodulel FE2 Module FET Module1 FES Madulel FE4 FWomeirt2 Rodulel FE5 Modulel FE6 TT MesuetEI itodule2 FEI Module2 FE2 Module2 FE3 MT wosuerres Module2 FEA mf El Figure 7 19 Port Mirroring 4 V SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Porn Mirroring Modulel FE1 mem TRIO LN a Mam near OE C wem E Figure 7 20 Port Mirrored 7 4 4 Port Trunking Click the Port Trunking in the left menu and enter the page as Figure 7 21 six trunk
16. SICOM3024SM Industrial Ethernet Switch User s Manual KYLAND Technology Co Ltd SICOM3024SM Industrial Ethernet Switch User s Manual Copyright O 2008 KYLAND Technology CO LTD All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Publisher KYLAND Technology CO LTD Address Chongxin Creative Building Shixing East Road 182 Shijingshan District Beijing China Website http www kyland cn postcode 100041 Tel 8610 88796676 FAX 8610 88796678 E mail sales kyland biz Version V1 Jan 2008 V2 Aug 2009 No 27030030 20 11 Preface SICOM3024SM is a high performance Gigabit industrial Ethernet switch specially designed by KYLAND Technology CO LTD for industrial applications The ports of SICOM3024SM support POE function IEEE802 3af the standard of POE divides power supply system into PSE Power Sourcing Equipment and PD Powered Device Its high performance switch engine solid and closed case design high efficient single ribbed casing for heat dissipation without fans over current overvoltage and EMC protection at power input side and excellent EMC protection of RJ45 port allow SICOM3024SM applicable in harsh and dangerous industrial environments The redundant function of optical fiber network and redundant power input function provide multiple
17. a 26 Chapter 6 Networking and Configurations eesseesssssceecccsssseecococsssssecococossesceocossssesesecocosssseceeeoossse 29 OL Networkinsssi lalla 29 62 SYSE ONT A ai RR 29 Chapter WEB AAA Me 31 7 1 dud 1 3 7 4 1a Enea 31 IDEVICe Status Dispiace 32 7 2 1 BICI aa 32 Vee Portelli 33 IZ Port Trate LON aia 33 Device Basic Con SUOMI aa 34 7 3 1 Contisure IPJXOdOTeSSosse tudine Rete coetu ecciesie Lp E tiere EE Eni 34 7 3 2 C onere Devre Name rta cien ae tom eens 35 153 3 laden 35 7 3 4 Change PASS W Ol caeso oen i OO oe E Oe e oue dillo delia 36 15352 Up Tade d MEME IE E E 36 7 3 6 OCW ALS VIa oa 37 7 3 7 Configure upload and download nono ono nononononnn ono nn nono nono nononoss 38 Device Advanced COAUTOR etit etit etam 38 7 4 1 POR TALES El A AAA AA AAA A E 39 7 4 2 ALAN md tud tuta Ru Mp MILLE M M D ME 39 7 4 3 PO MID ecco iat euro e D SL 4 7 4 4 Pocenia 42 7 4 5 Static Multicasting Address Table nnns 43 7 4 6 IONES ROODI siciliani 45 FAT SNMP CONSUL 0 a dtes cole a t edo oed n 46 7 4 8 cs A E du uui 47 7 4 9 AC ECON 1848121 8 6 e Ner ne Are CENT A e CONE OCP ERE AN e CORE TOPPER AC 48 TAIO SRS TEPC o ilaria 49 T TE DERD Conteo odes eet ro dara da crias
18. a cabling rack it should be placed separately from other cables 10 There must be the relevant marks at both ends of cable and the information on the marks should be explicit to facilitate maintenance A Attention When laying pigtails prevent optical fiber cable from knotting minimize the amount of turnings and avoid turnings with too small radius because turning with too small radius will result in serious consumption of optical signal of links affecting communication quality 23 KYLAND Chapter 5 Test methods Chapter 5 Test methods 5 1 Self inspection When electrify the equipment all service indicator lights will flash one time After 30 seconds the RUN indicator will keep flashing showing the devices work well 5 2 TP Port Test As shown in Figure 5 1 SICOM3024SM is powered on connecting any two RJ45 ports to two PCs by straight through cable and send Ping command to each other they can both get command from each other without packet loss The yellow light of the port should be always on PC work on 100M or always off PC work on 10M the green light should be blinking In the same way test all other RJ45 ports Operations on PING command is shown as the following example Figure 5 1 TP port test 5 3 POE Port Test As shown in Figure 5 2 SICOM3024SM is powered on connecting any two RJ45 ports to uplink Ethernet ports of PD at two sides by cross over or straight through cable and connectin
19. al RJ45 ports connect PD The procedures of 5 core terminal power connection refer to the DC power input terminal connection Figure 3 9 9 5mm POE power input terminal RS232 Network management interface CONSOLE The network management interface of SICOM3024SM is shielded RJ45 connector and its interface communication standard is 3 wire RS232 Users can use a network management cable with end bearing RJ45 plug and another end DB9F plug to connect the network management interface of SICOM3024SM with the 9 pin serial port of the control computer Operating the local management software to set up SICOM30248M by CLI The wiring sequence for network management interface of SICOM3024SM and the 9 pin serial port of PC computer is shown in Figure 3 10 KYLAND Chapter 3 Hardware Structure pin serial port of PC CONSOLE Port n Figure 3 10 CONSOLE wiring diagram Grounding SICOM3024SM Series Industrial Ethernet switch has a grounding screw hole in the rear panel After connecting one terminal of grounding wire with the cold pressing terminal insert it to the grounding hole and screw it down with grounding screws The other terminal of grounding wire connects to the ground The section of grounding wire is not less than 2 5 mm 19 v KY LAND Chapter 4 Hardware Installation Chapter 4 Hardware Installation 4 1 Installation requi
20. al customer service guideline according to the packing list and check the appearance quality of SICOM3024SM AN Warning For the built in precise parts of equipments please handle with care and avoid strenuous vibration to avoid affecting the performances of equipments KYLAND Chapter 2 Performance Specifications Chapter 2 Performance Specifications 2 1 System Specifications The system performance specifications of SICOM3024SM industrial Ethernet switch are shown in Table 2 1 Table 2 1 System Specs 24X 100Base FX SM MM ports System performance Ethernet Port Fiber port PoE Port Standard IEEE802 3 IEEE 802 3x IEEE 802 3u IEEE802 3af IEEE802 3ab IEEE802 3z IEEE802 1q IEEES02 1p IEEE802 1d IEEE802 1w Max Store and Forward speed 1488100 bps Max filtering speed 1488100 bps Switching mode Store and Forward Switching bandwidth of system 12 8G Electromagnetic compatibility interference ENS5022 Electromagnetic compatibility immunity EN50082 2 Physical port shielded RJ 45 RJ 45 port 10Base T 100Base TX supporting automatic negotiation function Port standard in line with IEEE802 3 standard Transmission distance 100m Optical power gt 13dbm SM gt 20dbm MM Receiving sensitivity lt 28dbm SM 35dbm MM Wave length 1310nm SM 1550nm SM 1310 nm MM Transmission distance 20 80Km SM lt 5Km MM Connector type LC SC FC ST Transmission rate 1 2Gbps Gi
21. and sending ping 192 168 100 10 1 1000 t return Reply from 192 168 100 11 bytes 1000 time lt 10ms TTL 128 for the second Reply from 192 168 100 10 bytes 1000 time lt 10ms computer Return TTL 128 after ten minutes for operating use CTL C command to Stat the missing rate If the missing rate is 0 shows the equipment are in good condition 27 KYLAND Chapter 6 Networking and Configurations Chapter 6 Networking and Configurations 6 1 Networking SICOM3024SM industrial Ethernet switch provides one to twenty four 10Base T 100Base TX Ethernet RJ45 ports each of which can provide link directly to the terminal devices or to another industrial Ethernet switch hub before terminal device as link share SICOM3024SM has four 4 pairs of redundant fiber ports of 100Base LX single mode or multimode The redundant Gigabit fiber ports can form backbone redundant fiber ring of 1000M with recovery time less than 50ms Furthermore SICOM3024SM supply maximum 24 pairs of redundant fiber port of 100Base FX SM MM or RJ45 ports which can form 100M redundant ring network with the recovery time less than 50ms It is widely used in electric power transportation energy water treatment and factory automation etc The typical networking topology of SICOM3024SM is redundant ring network SICOM3024SM can form the redundant fiber ring network as shown in Figure 6 1 in which one device is set as master and the rest are slave
22. at 5 UTP as transmission medium max effective 1000Base T transmission distance is up to 100m U Gigabit Ethernet which uses one pair of multi mode or single mode optical fiber to 1000Base LX transmit A characteristic that is automatically configured to adaptive mode for the speed Adaptive duplex and traffic control port The information capacity that the channel can transmit For instance the bandwidth o Bandwidth the Fast Ethernet is 100Mbps bit per second It expresses the signaling rate which is defined as the change times of the status for Baud Rate the electric or optical transmission medium within 1 second One of network equipments which run on the layer2 in the OSI layer7 model and it can be connected to the LAN or network segment which uses the same protocol It presents the automatic network address learning and network configuration function One data packet is sent to all equipments on the network Restless forward broadcast frame or multicast frame on bridge caused by the bridge Broadcast storm ring 67 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Use switches to set up the point to point connection among nodes in the LAN and Full Duplex allow them to receive and send data packet at the same time The communication for two nodes can only move toward one direction at the same Half Duplex time but can not move toward both directions It is the Medium Dependent Interface
23. cable locking screw insert the power cable into the hole at the terminal tail and screw down the power cable locking screw 3 Insert the power terminal into the DC power socket of the equipment and use a 2 5mm one slot screwdriver to screw down the two terminal locking screws to firmly connect the terminal with the power connector v KY LAND Chapter 3 Hardware Structure terminal locking screws Locking screws for power cables s mE power ground _ Y 24V protection ground Figure 3 7 DC Power connection AC Power input terminal AC220V Single phase three cores wire is used to for power connection The terminal integrates a fuse socket which is convenient to fix new AC power fuse Steps of replacing fuse are as follows 1 Pull out fuse holder from the AC power outlet as shown in Figure 3 8a Push a 2A fuse into the holder and also can put a standby fuse into spare slot 2 As shown in Figure 3 8b insert the fuse holder into AC power outlet standby fuse Working fuse Figure 3 8a STEP 1 17 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 18 Figure 3 8b STEP 2 POE Power input terminal 9 5mm The terminal of POE power input is 5 cores terminal as Figure 3 9 1 and 2 are positive poles 3 and 4 are negative poles 5 is for grounding protection Using POE should connect power into the 5 cores termin
24. ccord with the actual product For product upgrading information please visit our company s website or directly contact with our business representative Notice for Safety Operation This product offers reliable performances as long as it is used within the designed scope Artificial damage or destruction of the equipment should be avoided Carefully read this manual and well preserve this manual for future reference Do not place the equipments near water sources or damp places Do not place anything on power cable which should be placed in unreachable places Donottie or wrap the cable to prevent fire Power connectors and connectors for other equipments should be firmly interconnected and frequently checked In the following cases please immediately disconnect the power supply and contact with our company 1 Water gets into the equipments 2 Equipment damage or shell breakage 3 Abnormal operation conditions of equipment or the demonstrated performances have changed 4 The equipment emits odor smoke or noise Please keep optical fiber plugs and sockets clean During operation of equipments do not stare directly into the cross section of optical fiber Please keep the equipment clean if necessary wipe the equipment with soft cotton cloth Do not repair the equipment by yourself unless it is clearly specified in the manual Explanation of Warning Marks This manual uses tw
25. ck RMON Alarm in the left menu to configure as figure 7 46 Select alarm node in the MIB list and double click the OID will finish automatically In this page enter index no from 1 65535 owner serial no 1 32 and select port no ifindex 0 1 4 1 1 6 2 1 6 3 1 6 4 1 6 sampling type absolute delta alarm type rising alarm falling alarm rise or fall alarm sampling interval 1 65535 rising threshold value 1 65535 falling threshold value 1 65535 rising event index 1 65535 and falling event index 1 65535 Click Apply to finish 59 Y SICOM3024SM Industrial Ethernet Switch User Manual KY LAND MIB LIST RMOH Alarm 1213 MIB IfinLicaztPlds fs 6 1 2 15 2 2 1 10 nhJUcastPkts kyland linDiscards iflndex 1 1 lflnErrors absolute gt finUnknownProtos Rizing4larm Ift ctets IfCuutLUlcastP kts 200 futiilcastPkts fOutDiscards fGutErrors Alarm Information Demand Figure 7 46 RMON Alarm configuration 7 4 15 4 RMON Event Click RMON Event in the left menu to configure as figure 7 47 Enter index no from 1 65535 owner serial no 1 32 event type LOG SNMP trap Log and Trap event description 1 127 and event group 1 127 Click Apply to finish RMOH Event LG eme E Event Information Demand 60 v AY LAND Chapter 7 WEB Management Figure 7 47 RMON Event configuration 7 5 Device Management Device Management
26. ection of RJ45 port allows SICOM3024SM applicable in harsh and dangerous industrial environments The redundant function of optical fiber network and redundant power input function provide multiplex guarantee for reliable operation of the system SICOM3024SM series Gigabit industrial Ethernet switch offers strong web management which support CLI Telnet WEB SNMP and OPC based network management SICOM3024SM supports 2U 19 inch stable rack mounting for installation There are four uplink redundant 1000M SFP interfaces and max 24 10Base T 100Base TX ports or 24 pairs of 100Base FX SM MM fiber ports in back panel The redundant fiber or TP cable ring of 1000Mbit can be connected by redundant SFP interfaces with recovery time less than 50ms Each RJ45 port is self adaptive automatically configured to 10Base T or 100Base TX and full duplex or half duplex Auto MDI MDI X connection 1s also available It supports up to 24 RJ45 ports of 10Base T 100Base TX with POE function 1 2 System Features 1 High performance industrial Ethernet switch Plug and play for 1000M SFP changeable 4G fiber port provide various network for customers 4 100M modules each module provides six fiber ports or RJ45 ports v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Support various management software easy entrance for user such as WEB CLI TELNET SNMP OPC lOBase T 100Base TX self adaptive Ethernet connector full half duplex MDI MD
27. edundant ring network In the event of the system fault the recovery time of the redundant ring network is less than 50ms effectively increasing the reliability of network operation 13 Y SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 14 Figure 3 5 SFP Plug and Play unit Gigabit SFP FX TX Plug and play steps Figure3 6 Insert SFP unit There are two breaks on Fiber port LC and one break on Ethernet port RJ45 of SFP unit Insert the SFP into case backward to the PCB board The position is right when you hear a sound Ready for use 1f the SFP handle horizontal with connector Pull SFP unit The fiber part could be pulled out from SFP case when angle 90 degree between handle of SFP unit and connector O Pull out the fiber part from case break case handle Figure 3 6 SFP Process for Plug and Play KYLAND Chapter 3 Hardware Structure Optical Fiber interface SICOM3024SM offers 1 to 24 pairs of redundant 100Base FX full duplex single mode or multi mode optical fiber interface with SC FC and ST connector Optical fiber interface should be used in pairs TX and RX are a pair TX interface is the transmitting end connected to the receiving end RX of the optical fiber interface of another remote switch RX is the receiving end connected to the transmitting end TX of the same optical fiber interface of the same remote switch Eight pairs of redundant 100Base FX optical f
28. eration and port status helping detect and eliminate faults Table 3 1 describes the meanings of all indication lights on the front panel Table 3 1 descriptions for LED indicators 15 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 16 LED System state LED Blinking Switch operates normally RUN 1Hz Switch not operate Gigabit Optical fiber interface state LED Coptical fiber interface G1 G2 G3 G4 Effective network connection has been established for the DXP On port LINK Blinking Network activities are available for the port Ethernet RJ45 port state LED Fach RJ45 Ethernet port has two indicators a yellow lamp and a green lamp The yellow lamp indicates port speed and the green lamp indicates port link state 10M 100M 100M working status 1 e 100Base TX Yellow 10M working status i e 10Base T Effective network connection has been established for the On port LINK ACT Blinking Network activities are available at the port Green di No effective network connection has been established for the port DC Power input terminal DC24V or DC48V multi strand wires of more than 0 75 mm are used for power connection Connection sequence is shown in Figure 3 7 Connection and mounting procedures are as follows 1 Strip 5mm long sheath from power cable and twist the bare copper wires together into a bundle 2 Use a 2 5 mm one slot screwdriver to unscrew the power
29. g any RJ45 port of PD at two sides to the test computer sending Ping command to each other they can both get command from each other without packet loss The corresponding yellow light of the port is always on the corresponding green light is blinking showing the testing RJ45 ports run well In the same way test all other RJ45 20 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND ports Operations on PING command is shown as the following example PC2 Figure 5 2 POE port test 5 4 Fiber Port Test As shown in Figure 5 3 two units of SICOM3024SM are connected to fiber chain network connecting any one RJ45 port in each device to PCs by straight through cable and sending Ping command to each other They can both get command from each other without packet loss and the LINK ACT light of the fiber port should be always on showing the testing fiber ports work well In the same way test another pair of fiber ports Operations on PING command is shown as the following example 26 KYLAND Chapter 5 Test methods Figure 5 3 Fiber port test PING commands example Suppose the IP address for one computer is 192 168 100 10 and the other one is 192 168 100 11 operate the begin menu on the one computer and select the operation item input cmd or command sending Ping 192 168 100 11 11000 t operate the begin menu on the second computer and select the operation item input cmd or comm
30. g packets occupy 1 2 1 4 1 8 1 16 1 32 of bandwidth the packet are dropped Disable state won t control the broadcasting messages MAC address aging time is selected from 10 3600sec and 300sec is selected normally Click Apply to finish 57 SICOM3024SM Industrial Ethernet Switch User Manual Other Configurations Figure 7 43 Other configuration 7 4 45 RMON Configuration RMON configurations include statistics history Alarm and Event 7 4 15 1 RMON statistics Click RMON Statistics in the left menu to configure as figure 7 44 Enter index no from 1 65535 owner serial no 1 32 and select port no ifindex 0 1 4 1 1 6 2 1 6 3 1 6 4 1 6 Click Apply to finish RMOH Statistics Statistics Information Set Ti AE td Statistics Information Demand Figure 7 44 RMON Statistics configuration 7 4 5 2 RMON history Click RMON History in the left menu to configure as figure 7 45 Enter index no From 1 65535 owner serial no 1 32 and select port no ifindex 0 1 4 1 1 6 2 1 6 3 1 6 4 1 6 sampling no 1 65535 default number is 50 and sampling interval 1 3600 default number is 1800 Click Apply to finish 58 v KYI LAND Chapter 7 WEB Management ROH History D gt F ifIndex 1 1 kyland AA 1800 Apply History Information Demand Figure 7 45 RMON History Configuration 7 4 15 3 RMON Alarm Cli
31. gabit 125Mbps 100M Feeding power DC24V signal 1 2 3 6 Voltage 1 2 4 5 3 6 7 8 DC48V Signal 1 2 3 6 Voltage 4 5 7 8 Max power consumption for each port 29W Max power consumption of the end of 100m cable for each port 15 6W Output voltage DC24V DC48V Feeding input terminal 5 cores 9 5mm space inserting terminal Power supply Input voltage DC24V 18V 36V DC48V 36V 72V v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND DC110V 82V 185V AC220V 85V 264 DC220V 120V 370V Input power consumption 35W Over current Protection build in Physical dimensions height width depth 88 mm x 482 6 mm x 245 mm Mounting mode 19inch 2U stable rack mounting Heat removal method Single ribbed aluminum casing for heat Mechanical parameter dissipation without fan Outlet type back outlet for service Shell protection IP40 Weight 6 kg Operating temperature A0 C 75 C Ambient conditions Storage temperature 45 C 85 C Humidity 5 95 non condensing 2 2 Service Interface 1 1 to 24 10Base T 100Base TX RJ45 ports Each RJ45 port has self adaptation function capable of automatically configuring to 10Base T or 100Base TX state and automatically working in full duplex or half duplex operation mode Support MDI MDI X auto connection The transmission distance is 100m max 2 to 24 pairs of redundant 100Base FX single mode or multi mode optical fiber interfaces The maximum throu
32. ghput of each pair of optical fiber interface is 100Mbps and it is forced to work in 100M full duplex mode They support optical fiber line redundancy technology with the recovery time less than 50ms 3 Four redundant 100Base LX LC single mode or multi mode optical fiber interfaces or 10 100 1000Base TX RJ45 ports The maximum throughput of each pair of optical fiber interface is 1000Mbps and it is forced to work in 1000M full duplex mode They support optical fiber line redundancy technology with the recovery time less than 50ms 4 Conform to IEEE802 3 802 3U 802 3X 802 3Z 802 ab IEEE802 3af 5 Meanings of RJ45 port indicator yellow lamp rate indicator on 100M off 10M RJ45 Green lamp connection state indicator on effective connection of network blink network active off no connection After power connection all the indicators light up 30 seconds later they work into the state described above KYLAND Chapter 2 Performance Specifications 2 3 Service Function The service functions for SICOM3024SM mainly include LED Indicator The LEDs front panel indicate the port status correctly including transmission rate link status and system status Layer 2 Switching Switches work in two ways Cut Through and Store and Forward In Cut Through a data packet is immediately relayed further after detecting the target address in Store and Forward a data packet is first read in completely and checked for errors bef
33. groups are supported Each group allows max 4 ports Choose the port from the froup and Clic s to add or delete trunked port Click Apply to finish configuration See the sample at figure 7 22 Nor G1 G4can be in one trunk group independently but can not be in one group with ports of 100Mpbs The ports on the same VLAN can be trunked Port Trunk Figure 7 21 add trunking group 42 v AY LAND Chapter 7 WEB Management Trunk Configuration Figure 7 22 Port trunking sample 7 4 5 Static Multicasting Address Table Click the Static FDB Multicasting in the left menu and enter the page as Figure 7 23 select enabled and click Apply Add static multicasting MAC address VLAN ID and select port as shown in Figure 7 24 click Apply When it is finished click the Static Multicasting Address Table in left menu and see figure 7 25 To configure the multicasting address click Add and reset MAC address To delete the mutlcasting address select the serial No and delete Note Before enabling static multicasting address table IGMP Snooping must be closed firstly 43 KYLAND SICOM3024SM Industrial Ethernet Switch User Manual Static FOB Multicast transmit unknown Static FOR Multicast List Static FDB Multicast List Configuration Fort List Modulel FEl a ModulelFE2 Madcdulel FE3 Figure 7 23 Static Multicast address table
34. he port for transferring is blocked the port in blocking state can be used as v KYI LAND Chapter 7 WEB Management transferring port with the recovery time less than 50m Configure four switches connecting by DT Ring there are only two standby ports in two rings The two standby ports are chosen from one ring DI PORT DIPORTO Figure 7 34 DT Ring 3 RING DT Ring Add VLAH List Figure 7 35 DT Ring configuration based on VLAN bl Y SICOM3024SM Industrial Ethernet Switch User Manual KY LAND E RING2 Module3 FE1 Module3 FE2 Enable Madule3 FE3 Cancel Figure 7 36 DT Ring configuration based on ports DT PORT RING 2 2 52 v KYI LAND Chapter 7 WEB Management DT Ring Configuration Enable v Module3 FE3 DT Ring State List Figure 7 37 DT Ring configuration successfully 7 4 12 POE Configuration Click the POE Configuration in the left menu and enter the page as Figure 7 38 select Enable or Disable for all ports In the Enable state POE function can work The output power consumption is 5W 10W and 15W which can be chosen according to the power consumption of PD Support function of voltage detection Under the Enable state of voltage detection the power is automatically disconnected when the voltage lowers than 22V or 28V Web page shows output current voltage power cons
35. iber interface can be used to form an optical fiber redundant ring network In the event of the system fault the recovery time of the redundant ring network is less than 50ms effectively increasing the reliability of network operation RJ45 interface SICOM3024SM offers 1 to 24 10Base T 100Base TX RJ45 Ethernet ports Each RJ45 port has self adaptation function support MDI MDI X auto connection and can be connected to end equipments servers hubs or other switches in straight through or cross over way Each port supports IEEE802 3x self adaptation so the most suitable transmission mode half duplex or full duplex and data rate 10 Mbps or 100Mbps can be automatically selected the connected equipment should also support this characteristic If the equipment connected to these port does not support self adaptation the ports will be able to send at proper speed but transmission mode is defaulted as half duplex POE Interface SICOM3024SM has 1 to 24 RJ45 ports of 10Base T 100Base TX with POE function Each RJ45 port supports feeding output of DC24V and DC48V and provides maximum current of 600mA to remote Ethernet devices or industrial Ethernet switch at the power receiving end The maximum power consumption of port is configured to 5W 10W and 15W through the network management Each RJ45 port supports self adaptive function and MDI MDI X auto connection LED Indicators The indicators on the front panel of SICOM3024SM can show system op
36. in which one Ethernet port is taken as the MDI receiving terminal to connect to the port of other equipment MDI X Medium Dependent Interface Cross over 68 v AY LAND Appendix D FTP Application for Switch Software Update Appendix D FTP Application for Switch Software Update You can use web management to upgrade SICOM3024SM software through switch by FTP protocol Switch as Ftp client PC as Ftp server Before update you need to setup the Ftp server FTP server is well known software and can be downloaded on the internet Here is the step for configuring FTP server 1 Install WFTPD in PC Startup WFTPD shown in figure D 1 a No log file open WETPD File Edit View Logging Messages Omnis Help General Users rights Host net Add delete or change users passwords and home directories 1 socket users CAP NUM Figure D 1 start up WFTPD software 2 Type in user name password main path click on Security menu click on Users rights click on the New User in the User Rights Security Dialog window As Figure D 2 User Name User New User Home Directory DB Help Rights gt gt 69 V SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Figure D 2 WFTPD configure user name and password 3 Type in your user name in New User window here is test click OK as Figure D 3 User Rights Security Dialog User New User User Name test Cance
37. includes reset logout 7 5 1 Restart Click Reboot in the left menu and enter the page as figure 7 48 Click Reboot to reset the device Reboot Figure 7 48 Reboot 7 5 2 Logout Click Logout in the left menu and enter the page as figure 7 49 Click Logout to exit Logout Logout Figure 7 49 Logout 7 6 Configurations Click Save Configurations in the left menu and enter the page as figure 7 50 Click Save to save all settings Save Configurations Figure 7 50 Save Configurations 6 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 7 7 Load Default Click Load Default in the left menu and enter the page as figure 7 51 Click Load Default to restore all default settings Load Default Figure 7 51 Load Default 62 KYLAND Appendix A Twisted pair and Pin Distribution Appendix A Twisted pair and Pin Distribution For the connection of 10Base T 100Base TX the twisted pair must have two pair cable Each pair is distinguished with two different colors For example one strand is green and the other is the alternate of green and white stripes RJ 45 connector should be equipped at both ends of the cable AN Warning Don t insert a telephone plug into any RJ 45 port Only use twisted pair with RJ45 connectors at both ends conforming to FCC standard Fig A 1 Shows how the connector
38. king Modes SICOM3024SM is able to configure the working mode of all ports through management full half duplex adaptive 10M half duplex 100M half duplex 10M full duplex 100M full duplex etc Configure Port Traffic Flow You can configure the TX and RX rate of all ports via the management software of SICOM3024SM For port of 100Mbps it can be set as 128K 256K 512K IM 2M 10M SOM 100M For Gigabit port it can be set as 100M 500M 1000M Static Multicasting Communication You can add multicasting users by adding static multicasting table manually Compared to dynamic multicasting it is more simple reliable and faster without protocols You can forward the multicasting data by configuring static multicasting forwarding tables Users can manually configure the multicasting communication according to their needs Static multicasting can not be used together with IGMP simultaneously IGMP IGMP is Internet Group Multicast Protocol SICOM3024SM series offers IGMP monitor and query functions Data packets can be transmitted to multiple necessary host computers to prevent overloading This solves the problems of occupied bandwidth when broadcasting Broadcasting Storm Control SICOM3024SM series offers broadcast storm protection ensuring the smooth communication platform of the switch network The switch will filter out the over flow once the bandwidth of broadcast flow exceed the limit DT Ring DT Ring is specially designed and
39. l Help Rights gt gt Figure D 3 WFTPD configure user name 4 In Change Password window type in the password in New Password and Verify area for example test click OK Rights gt gt Do Figure D 4 WFTPD configure password 5 Set main path in home directory here is E study User Rights Security Dialog x UserName tes El User New User Delete Change Pass Home Directory E Restricted to home Help Rights gt gt Figure D 5 configure user information L Click Done to finish FTP server setup Upload the software to home directory on FTP server here is under E study FTP server setup is finished now For the successful setup we support two software versions Host and Backup The Host version is the one we currently used which is not 70 KYLAND Appendix D FTP Application for Switch Software Update allowed to update for the purpose of protecting software We use WEB management software to upgrade it steps 1 Enter into WEB management page click navigation bar to set Update as Figure D 6 Software Update a sicomi024sm bin Figure D 6 Software Update 2 Set FTP server IP address user name password Update software name click Apply button record update software ID 3 Wait for upgrade software Update successful 4 Click on navigation bar to
40. n in the left menu and enter the page as Figure 7 30 click port configuration and enter the page as Figure 7 31 choose anble disable for all ports click apply to finish port status configuration Click Add List from Figure 7 30 enter the page as Figure 7 32 select Group number Item number Action and Control port fill out the items Source MAC Destination MAC Ethernet Type Vlan Tag click apply to finish configuration c IP ACL Help Figure 7 30 IP ACL 48 v KYI LAND Chapter 7 WEB Management Configure ACL Port Status Configuration Enable Enable Module FE1 Module FE Module FES Disable Module FES Disable Module FES Disable Module FEE Disable Module 2AF E1 Disable Module2 FE2 Disable Module2 FES Disable Module FE4 Disable Disable Disable Modules FES Module FEB Figure 7 31 Port state configuration Configure IP ACL Configure Item ae Figure 7 32 ACL protocol configuration 7 4 10 RSTP Configuration Click the RSTP in the left menu and enter the page as Figure 7 33 select RSTP or STP to configure fill out in the items Spanning Tree Priority From 0 to 65535 The default is 32768 with the step of 4096 Hello Time from 1 to 10 The default is 2 Max Age Time From 6 to 40 The default
41. o kinds of noticeable warning signs to arouse special attention of users during operation The implications of these signs are as follows gt BD Warning pay special attention to the notes behind the mark improper operation will result in serious damage of the switch or injury of operation personnel Caution attention warning danger remind the positions requiring attention during operation CONTENTS Chapter System VET VIO Westin liana 1 bill Produc RO Nile 1 L2 A a Dan MEME E MA Ca MR ERE e l 1 35 Packime list and unpackino check out ntt tuta ult tna ceo ere boten b tere decent bibe bestens 3 Chapter 2 Performance Specifications ccccccccsssssssssesssssnssccccccsssccsssssssvessssssscccccccosecccsssssscccessseees 5 Zub Soyer ope eaS rar tancia nara dao acaecido ra cnt tata E eet 5 22 e aa cbacci 6 23 SCIVICERUNCUON silice 7 Chapter3 Hardware StructioieL elia 11 del OY SECT SEI 11 Dl AMES UC irta 11 3 2 1 E E 11 3 2 2 LTOHCDOIBeT cain E OO EOI nhe A T emt tre tere us 12 3 2 3 Back PA PE 13 Chapter 4 HardwareInstallation iaia aaa 21 Al Thistallationteguinement aulico 21 Az Mamirame IBsEallatlofi essei lille Ae 21 4 2 1 A nine ee RM Rm en MMC M M C Sa Ser re oe Seen 2l Chapters Testmethodssaigsi siderali 25 Sl SLIP 25 A Y A ii oil 25 xo TOETO ur PT 25 3A FIDE POR TEST eroinin iii sid
42. of RJ 45 is numbered please make sure that the inserting direction is correct Figure A 1 Connector of RJ 45 Pin distribution of 10Base T 100Base TX Unshielded twisted pair UTP or shielded twisted pair STP will be used for the connection of RJ 45 for the connection of 10Mbps category 3 4 and 5 of 100 ohm will be used and cat 5 of 100 ohm will be used for 100Mbps Additionally do make sure that the connecting length of any twisted pair shall not exceed 100 meter Port of RJ 45 supports automatic MDI MDI X operation PC or server may be connected with straight through cable or connect with other switch or hub In straight through cable pin 1 2 3 and 6 at one end of the cable are connected to pin 1 2 3 and 6 at the other end of the straight through cable respectively Cross over cable must be used for switch or hub with MDI X port The pin distribution of 63 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 10Base T 100Base TX is listed in the table A 1 Table A 1 Pin distribution of 10Base T 100Base TX MDI X signal name MDI signal name Pg Output data TD Receiving data RD Unused Unused Note denoting cable polarity Definition of straight through cable from RJ45 8 pin to RJ45 8 pin The connection sequence is in turn Orange white Orange Green white Blue Blue white Green Brown white and Brown Figure A 2 Cable
43. ore the switch relays the same SICOM3024SM employs Store and Forward that is a switching mode widely used VLAN VLAN will divide one network into multiple logical subnets Data packets cannot be transmitted between different VLANs so as to control the broadcast domain and segment flow and improve the reliability security and manageability SICOM3024SM series supports IEEE802 1q VLAN tag It can be divided into up to 4094 VLANs based on ports The VLAN division can be realized via WEB CLI etc VLAN Tag packet is transmitted transparently QoS Priority IEEE 802 1p is the most popular priority solution in the LAN environment SICOM3024SM series supports 802 1p as well as IP TOS and DSCP by which you can configure the port based priority when the terminal does not support the above trhee configurations and different priority for the ports is wanted This configuration can only affect the packets without priority in the port SICOM3024SM supports four class of priority Port Trunking In SICOM3024SM multiple physical ports can be aggregated into one logic port which has the same rate duplex and VLAN ID Port Trunking can be configured in one single switch for max 4 ports In this way the pressure of network traffic 1s reduced Port Mirroring The data of one port can be mapped to another port for user to real time monitor the Y v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND communication Configure Port Wor
44. r 3 Hardware Structure Chapter 3 Hardware Structure 3 1 System Structure SICOM3024SM hardware is structured as Figure3 1 Switching Network Controller POWER Fiber 102103G4 port Power Input Figure 3 1 Hardware Structure System hardware mainly consist the following parts 1 Switching network controller employs ASIC chip technology offering layer 2 wire speed transfer of data packets 2 Integrated module of transmitting and receiving for fiber interfaces 3 Industrial power supply with protection of over current over voltage and EMC 4 EMC protection for all RJ45 ports 3 2 Switch Structure 3 2 1 Case SICOM3024SM case is 19inches 2U stable rack mounting type structure The entire unit has a six side enclosed structure with protection class up to IP40 The case s top side plates made of ribbed aluminum profile are a part of the heat dispersion system of the 11 v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND entire unit The single ribbed structure can double heat dissipation area The heat generated when the unit is working 1s effectively dissipated into the environment via the ribbed heat dissipation surface in the form of radiation and convection greatly increasing the high temperature resistance of equipment Discarding the traditional form of axial fan heat dispersion reduces power consumption of the entire unit and increases the stability of the system The figuration of SICOM302
45. rement As a monomer structure switch it can be fixed on standard 19 rack Before installation make sure all condition match the installation requirement 1 Power supply DC24V DC48V DC110V AC220V DC220V Please pay attention to voltage level 2 Environment 40 C 75C Relative humidity 5 95 non condensing 3 Earth resistance lt SQ 4 Make sure all fiber cables and connectors are ready for use 5 Avoid sunshine and strong EMC area 6 19 inches rack is ready for SICOM3024SM 7 Check if you have all necessary cables and connectors 4 2 Mainframe installation 4 2 1 Stable rack mounting SICOM3024SM industrial Ethernet switch can be installed in any standard 19 Inch Rack Before mounting make sure the following is ready 1 Make sure there is enough space on the rack for SICOM3024SM installation 2 The power supply is available for SICOM3024SM After selecting the mounting location fix the SICOM3024SM with four screws M5x14 21 SICOM3024SM Industrial Ethernet Switch User Manual 482 6 ANYLAAD nis 12030245 Mina ra etc mut uud zd uui o 31227 852222 200023 222208 22 000 Figure 4 1 SICOM3024SM mounting drawing Cable wiring should meet the following requirements 1 Before wiring check whether the specifications models and quantities of all cables comply with the construction drawing design and contract requirements 2 Before cable wiring it is necessary to check whether
46. s in the left menu and enter the page as Figure 7 6 where you can modify IP address subnet mask and gateway with click on Apply button To make the modification take effect you need to restart the switch 34 v KYI LAND Chapter 7 WEB Management IP Address 192 168 0 2 255 205 200 0 192 188 0 1 Figure 7 6 Configure IP Address 7 3 2 Configure Device Name Click the Device Name in the left menu and enter the page as Figure 7 7 fill in the device name and click Apply button Device Hame EYLAND EYLAND Figure 7 7 Configure Device Name 7 3 3 Port Configuration Click the Port Configuration in the left menu and enter the page as Figure 7 8 where you can configure port state enable disable auto negotiation enable disable port speed 10 100M duplex full half flow control open close After configuration click Apply to make it take effect 35 Y SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Configure Port wee rer mx Enable wf enable xf or e o fore x pasa rez Di fo m enable 0 m anion ey Ore eaae res i ao m ivi a a fr ey ore oat res 1 ao Enable gra pra eaae FES Di Enable m Enable rl ore oat FES Di Enable m Enable 00 cm fl a pere Di fenable m enable m 07 al ore eaae rez Di ao m Enable rl ra Moaea FES 1 ao m ii a TO rl
47. s of networking devices software and system employ it It is easy to realize open and free and can be used to control various devices RMON RMON is a standard monitoring regulation to switch the network monitoring data between network monitor and console system It offers more selections for network operator to use the suitable console and network monitor for special requirements It is also the expansion to SNMP functions and is specially useful for monitoring and managing LAN The purpose of developing RMON is to provide statistic result of information flow and analyze network parameters so as to work out a comprehensive diagnoses plan and regulation By RMON you can operate among multiple manufacturers for SNMP management and monitoring agent What s more it can offer a standard for a group of MIB to v SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 10 collect the network statistics which is not available via SNMP RMON realizes previous network diagnoses by using powerful alarm group it allows that a domain value is set for critical parameters so as to automatically send alarm signal to manager control center POE function SICOM3024SM support POE function SICOM3024SM POE board can be used as an independent module group It supports max 6 FE ports with POE function Each FE port is compliant with the power supply of IEEE802 3af standard The module group can work under 24V and 48V v KY LAND Chapte
48. se T 100Base TX RJ45 ports Support POE feeding output of 24V 12W SM3 6TX PSE 48V 6 x 10Base T 100Base TX RJ45 ports Support POE feeding output of 48V 12W 30 v KY LAND Chapter 7 WEB Management Chapter 7 WEB Management SICOM3024SM support WEB page management through web page you can monitor the working state of the switch and configure and upgrade the switch online 7 1 Login Web Page Connecting the SICOM3024SM switch with a computer input the IP address eg 192 168 0 2 in the IE browser a window will appear as Figure 7 1 the default user name and password are admin and 123 click OK to enter MA PESE qe ERE ttik 122 188 0 2 Piedi WEA SICOM PERRA P UE meq dim y m a ASSAI E m Figure 7 1 Login Page The main page is as Figure 7 2 At the left of the page is the management tree menu including device state basic configuration advanced configuration device management save all changes restore default settings and so on each menu may include some submenu 31 V SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Sicom3024SM Web Management System p About Help Exit B 13 Close Up GExpand ff Sicom3024SM Web Management System amp Device Status f Basic Configurations H Advanced Configurations Device Management el Save Configurations Y Load Default Jb m TR HERE EISE OS S IR 28 www kyland com cn
49. sequence of straight through cable Definition of Cross over cable from RJ45 8 pin to RJ45 8 pin xli The connection sequence is in turn Orange white Orange Green white Blue Blue white Green Brown white and Brown Green white Green Orange white Blue Blue white Orange Brown white and Brown Figure A 3 Cable sequence of cross over cable 64 v AY LAND Appendix B Cable Type and Specifications Appendix B Cable Type and Specifications The cable type and specifications are shown as table B 1 Table B 1 Cable type and specification Connect Cable Type Max length or 10Base T Cat 3 4 and 5 100 ohmUTP RJ 45 100Base TX Cat 5 1000hmUTP RJ 45 50 125 or 62 5 125um core 100Base FX i 5km 1310nm MM SC FC ST multi mode fiber MMF 9 125um single mode fiber 40km 1310nm SM 100Base FX SC FC ST SMF 80km 1550nm SM 1000Base T Cat 5 100 ohm UTP RJ 45 9um or 10um core sigle mode 1000Base LX Skm fiber 1310nm 50 125 or 62 5 125um core 1000Base LX multi mode fiber MMF 550m LC 850nm 65 v KY LAND Appendix C Glossary Appendix C Glossary Twisted pair standard of Cat3 Cat4 and Cat5 in IEEE specification for 10Mbps 10Base T Ethernet Twisted pair standard of Cat5 or above in IEEE specification for 100Mbps Fast 100Base TX Ethernet Fast Ethernet which uses one pair of multi mode or single mode optical fiber to 100Base F X transmit Gigabit Ethernet which using C
50. there is damaged cable and whether the cables are accompanied by ex factory records and vouchers attesting their quality such as quality assurance certificate etc 3 The specifications quantities route directions and laying position of the cables to be laid should meet the design requirements of construction drawings The laying length of each cable should be determined according to its actual position 4 No intermediate break or joint is allowed for the cables to be laid 5 User s cables and power cable should be laid separately 6 Inside walkways the cables should be properly arranged in good order with uniform smooth and flat turnings 7 Cables should be straightly laid in cable channels Extruding of cable from cable channels to block other outlet or inlet holes is not allowed The cables at 22 KYLAND Chapter 4 Hardware Installation the outlet part of cable channel or at turnings should be bundled and fixed 8 If cables power line and grounding conductor are laid in the same channel cables power line and grounding conductor should be not folded or blended together If a cable line is overly long coil and place it in the middle of the cabling rack do not let it cover on other cables 9 When laying the pigtail avoid knotting of optical fiber cable minimize the amount of turnings and avoid turnings with overly small radius Bundle pigtails in proper tightness and avoid too tightly bundling If laid on
51. ue 0 LOWEST 1 SECLOW 2 SECHIGH 3 HIGHEST Apply Back Figure 7 40 802 1P priority configuration 55 V SICOM3024SM Industrial Ethernet Switch User Manual KY LAND Click IPTOS Priority and enter the page as figure 7 41 There are total 8 classes for IPTOS SICOM3024SM supports four of them You can select 1t and click Apply IP TOS Priority Configuration IP TOS Priority 0 7 oe o 0009s 9 Queue 0 LOWEST 1 SECLOW 2 SECHIGH 3 HIGHEST Figure 7 41 IPTOS priority configuration Click DSCP Priority and enter the page as figure 7 42 There are total 64 classes for DSCP SICOM3024SM supports four of them You can select it and click Apply 56 KYLAND 7 4 14 Chapter 7 WEB Management DSCP Priority Configuration DSCP Priority 0 63 DCP O DSCP 4 DSCP 8 DSCP B5 DSCP 10 DSCP 14 rin mim mcm miu m 0 o pium oy oF A od cH cr c c Cs oj ul OIOI c y a val a v Ble elo ow be bm amp amp jlolo miae zs amp io m tn Queue D LOWEST 1 SECL OW 2 SECHIGH 3 HIGHEST Figure 7 42 DSCP Priority configuration Other configuration Click the Other Configurations in the left menu and enter the page as Figure 7 43 which include two configurations of broadcasting storm control and MAC aging time There are totally five options for broadcasting storm control disable 1 2 1 4 1 8 1 16 1 32 When the broadcastin
52. umption etc 53 V SICOM3024SM Industrial Ethernet Switch User Manual KY LAND POE Configuration Figure 7 38 POE configuration 7 4 13 QoS Configuration Click the QOS Configuration in the left menu and enter the page as Figure 7 39 enable QoS weight WRR and preemption mode Priority based on 802 1P or IO TOS DSCP and port are for options The priority based on 802 1p and IP TOS DIFF can be used at the same time and they can not be used together with priority based on port AN Attention There are two classes for priority based on port and four queues for others Configure Qos Qos Mode 802 1P Priority IP TOS Priority 2 sable mmi DSCP Priority Hq preempt Weight of the Priority Queues Cs Ja I2 tt 54 v KYI LAND Chapter 7 WEB Management Configure dos Qos Mode 802 1P Priority WEE IP TOS Priority DSCP MODE DSCP Priority IPTOS MODE DSCP MODE Weight of the Priority Queues Cs IL IL 2 ID t j Configure Port Priority Module FEA Modulet FEZ Modulet FES Module F E4 Modulet FES Module FEG Modules FEA Module FE Module 2 FES 2 i Figure 7 39 Qos configuration Click 802 1P Priority and enter the page as figure 7 40 There are total 8 classes for 802 1P SICOM3024SM supports four classes You can select it and click Apply 802 4P Priority Configuration 02 1P Priority 0 7 Que
53. up version and click OK as shown in the Figure 7 11 of software version Click reset in the navigation bar and click reset Wait for 30 seconds to start up network management system Click Device Basic Info check software version to confirm if it is upgraded successfully 7 3 6 Software Version Click the Software Version in the left menu and enter the page as Figure 7 11 which displays two versions one is startup and another is closed This function is for the purpose of upgrading software Software Version Figure 7 11 Software Version 37 V SICOM3024SM Industrial Ethernet Switch User Manual KY LAND 7 3 7 Configure upload and download Click the Upload Download Configuration in the left menu and enter the page as Figure 7 12 enter server IP address and file name to be uploaded downloaded user name password and click Apply to take effect See the details of FTP configurations in Appendix D o Select upload or download file and set FTP server IP address file name user name password and file name to be upgraded click Apply as shown in Figure 7 12 FTP server address and IP address of switch should be in the same segment o After clicking Apply upload or download successfully Upload amp Download Configuration Upload file Su Ed Li DL Apply Figure 7 12 Upload amp Download Configuration
54. x guarantee for reliable operation of the system The user s Manual for SICOM3024SM Industrial Ethernet Switch mainly introduces the information on technical principles performance indexes installation and commissioning network management etc to provide users with references in startup expansion and routine maintenance It is a practical teaching material that can be used for knowledge and understanding of SICOM3024SM industrial Ethernet Switch This manual mainly includes the following contents Chapter 1 Overview and system features of SICOM3024SM industrial Ethernet switch Chapter 2 Performance and service functions of SIOCM3024SM industrial Ethernet switch Chapter 3 Hardware structure of SICOM3024SM industrial Ethernet switch Chapter 4 Installation of SICOM3024SM industrial Ethernet switch Chapter 5 Field test methods for SICOM3024SM industrial Ethernet switch Chapter 6 Networking modes and system configuration of SICOM3024SM Chapter 7 WEB management of SICOM3024SM industrial Ethernet switch Appendix A Introduces twisted pair and pin distribution rules of SICOM3024SM industrial Ethernet switch Appendix B Introduces cable types and specifications of SICOM3024SM industrial Ethernet switch Appendix C Introduces abbreviations used in this manual Appendix D FTP application of software upgrade 11 Statement as product and technology upgrades and improves constantly the contents of this document may not completely a