1. EQUIN X www prolight co uk POWER FLiS WER Order code EQLED77 User manual Equinox Power Flower Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Equinox Power Flower Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment
2. WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks LED failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Equinox Power Flower Technical specifications You should find inside the carton the following items 1 Equinox 2 Power cable 3 User manual Technical Specifications DMX channels 1 3 or 5 selectable Sound Activated auto DMX and master slave e 1x 20W white COB LED e 11 static Gobo s e 4 Push button LED digital display 0 100 dimming and variable strobe via DMX IEC Power in out sockets e 3 Pin XLR in out sockets Power consumption 45W Power supply 100 240V 50 60Hz Dimensions 232 x 281 x 260mm 195mm with folded bracket Weight 4 3Kgs Overview Po 1 4 x u 3 cl 10 t O i 9 7 O Q DMX OUT CRG j O ie O 3 3 2 E O Ls sWER lt 6 DMX IN CY Q www prolight co uk O prolig S O Q Identification 1 Hanging bracket 2 Earth screw 3 Safety eye 4 LED display 5 Function buttons 6 DMX input socket 7 DMX output socket 8 IEC power in socket 9 IEC power o
3. Do not open the equipment and do not modify the equipment Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 100V 240V Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS
4. ENTER button and using the UP and DOWN buttons accordingly 1 o St Set the offset of the gobo wheel from 0 100 or 100 2 noto Review the motor reset status If the LED display shows G nG then the gobo wheel motor has failed If the LED display shows G nY then the gobo wheel motor has reset successfully If the LED display shows r nG then the rotation wheel motor has failed If the LED display shows r nY then the rotation wheel motor has reset successfully 3 rSt Resets the unit to its factory settings To come back out of the above mode press the MODE button until you are back at the main menu Equinox Power Flower DMX charts 1 channel DMX chart me a mee 1 3 channel DMX chart amme vow tn Rotation wheel 360 degree rotation 180 214 Rotation wheel clockwise rotation 215 255 Rotation wheel anti clockwise rotation 1 2 3 fF 3 0 255 LED brightness 0 100 Equinox Power Flower DMX charts 5 channel DMX chart ame vane Fon Gobo wheel anti clockwise rotation Rotation wheel 360 degree rotation Rotation wheel clockwise rotation Rotation wheel anti clockwise rotation LED brightness 0 100 No function No function Strobe slow to fast When in sound active 0 255 sensitivity Equinox Power Flower DMX set up DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility w
5. the ENTER button using the UP and DOWN buttons accordingly GorG Static gobo G cu Spins the gobo wheel in a clock wise direction Gccu Spins the gobo wheel in a anti clock wise direction GPoS Gobo selector Use the up and down buttons to scroll through the 11 static gobos GPoS Spins the gobo wheel clock wise and anti clock wise ORWN To come back out of any of the above options press the MODE button Gobo rotation disc options While in the auto mode press the MODE button to show Gobo on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 4 settings by pressing the ENTER button and using the UP and DOWN buttons accordingly r orG Static rotation disc r cu Spins the rotation disc in a clock wise direction r ccu Spins the rotation disc in a anti clock wise direction GPoS Spins the rotation disc clock wise and ant clock wise 5 amp N To come back out of any of the above options press the MODE button Equinox Power Flower Operation modes Auto run mode continued LED Setting options While in the auto mode press the MODE button to show LED on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 2 settings by pressing the ENTER bu
6. der in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation The Equinox Power Flower can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split Equinox Power Flower DMX Set Up Notice Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 in 3 pin XLR XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground O Pin 2 Negative DMX 512 out 3 pin XLR se te a as s
7. es at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please seperate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal EQUIN X www prolight co uk
8. hen it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The or
9. s a maar Fa a eue ie a ca a fe me en ty FIGURE 3 FIGURE 2 Special Note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a Q DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 3 pin CABL89 5 pin will decrease the pos sibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 3 Pin XLR socket Pin 1 GND seteen Pin 2 Signal Pin 3 Signal 5 Pin XLR socket 3 Pin XLR socket Pin 1 GND sereen Pin 1 GND screen Pin 2 Signal Pin 2 Signal En 3 Signal Pin amp N C Pin 3 Signal R Equinox Power Flower Notes Notes Correct Disposal of This Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries with seperate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wast
10. tton and using the UP and DOWN buttons accordingly 1 E con Set the brightness of the LED from 000 255 000 off 255 full on 2 E pro Sets the led into fade in and fade mode Fade speed can be set from 00 15 00 slow 15 fast To come back out of any of the above options press the MODE button Note After completing your settings the auto run mode will run according to your settings Built in programmes mode To access the built in programmes mode press the MODE button on the LED display to show PRO on the LED display Now press the ENTER button and use the UP and DOWN buttons to select between the programme options PRO1 or PRO2 PR01 This programme is set to a slow rotation with fade in and fade out PRO2 This programme is set to a fast rotation with fade in and fade out Master slave mode To access the master slave mode press the MODE button on the LED display to show SLAV on the LED display The unit will now run in sequence with the master unit set in any of the modes Factory reset menu mode Note you only need to go into this mode if the LED display shows err on the LED dis play on start up To access the setting mode press the MODE button on the LED display to show SET on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 3 settings by pressing the
11. ut socket 10 Hanging bracket tightening knobs Equinox Power Flower Operation modes Operation modes DMX mode To access the DMX mode press the MODE button on the LED display to show 512 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the desired DMX address setting from d001 d512 Once you have selected the desired DMX address setting press the ENTER button to choose one of the 1 3 or 5 DMX channel modes use the UP and DOWN buttons and press the ENTER button to confirm the setting For DMX functions please refer to the DMX function chart over leaf Sound active mode To access the sound active mode press the MODE button on the LED display to show SUND on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity level from SUOO SU31 Note SU00 Low SU31 High Auto run mode To access the auto run mode press the MODE button to show Auto on the LED display In this auto run mode there is three setting options to choose from Gobo Gobo settings options RoAt Gobo rotation options IEd LED setting options Gobo setting options While in the auto mode press the MODE button to show Gobo on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 5 settings by pressing