Home

Agilent Technologies 1000 Series Portable Oscilloscopes

image

Contents

1. ee Agilent Technologies 1000 Series Portable Oscilloscopes Data Sheet Engineered to give you more scope than you thought you could afford Agilan Technotog gh Agilent Technologies More scope than you thought you could afford Agilent s new 1000 Series oscilloscopes deliver the performance and features you expect in a big scope and the portability and low price you require in a small one We ve redefined the economy scope by giving you more more signal viewing more capabilities and more productivity Weighing less than 7 pounds with a small footprint the 1000 Series can go anywhere with ease All 1000 Series models feature a maximum sample rate of 2 GSa s and a maximum memory depth of 20 kpts 2 channel model 4 channel model DSO1002A 60 MHz DSO1004A 60 MHz DSO1012A 100 MHz DSO1014A 100 MHz DSO1022A 200 MHz DSO1024A 200 MHz Whether your job is designing products in R amp D teaching the next generation in education or testing in manufacturing or service the new 1000 Series oscilloscopes can help get it done with confidence R amp D Education Manufacturing Figure 1 Features normally only found on much Figure 2 Economical prices make the 1000 Series Figure 3 Standard go no go mask testing is just higher priced scopes equip the 1000 Series to bea ideal for teaching basic scientific and one of the reasons manufacturing and service test powerful choice for R amp D applications engineering measurements
2. 2 3 4 Ext Ext 5 AC Line edge only 25 mV div 1 div from DC to 10 MHz 1 5 div from 10 MHz to full bandwidth lt 5 mV div 1 div from DC to 10 MHz 1 5 div from 10 MHz to 20 MHz Manual track waveform or automatic measurement selections Manual and track waveform selections provide readout of Horizontal X AX 1 AY and Vertical Y AY Maximum minimum peak to peak top base amplitude average RMS overshoot preshoot Period frequency rise time fall time width width duty cycle duty cycle delay A gt B rising edge delay A gt B falling edge phase A gt B rising edge and phase A gt B falling edge Integrated 6 digit frequency counter on any channel Counts up to the scope s bandwidth 200 MHz max Mode to display all single channel automatic measurements simultaneously on the display A B A B AxB FFT Source channel selection for A and B can be any combination of oscilloscope channels 1 and 2 or 3 and 4 on DSO1xx4A Finds and displays all active channels sets edge trigger modes on highest numbered channels sets vertical sensitivity on channels time base to display 2 periods Requires minimum voltage gt 20 mVpp 1 duty cycle and minimum frequency gt 50 Hz 5 7 inch diagonal color QVGA TFT LCD display with 300 cd m backlight intensity OFF Infinite Dots Vectors 400 waveforms sec 10 setups and 10 waveforms can be saved and recalled using internal non volatile memory locations 1 referenc
3. www agilent com www agilent com tind 1000 For more information on Agilent Technologies products applications or services please contact your local Agilent office The complete list is available at www agilent com find contactus Americas Canada 877 894 4414 Latin America 305 269 7500 United States 800 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 421 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe amp Middle East Austria 01 36027 71571 Belgium 32 0 2 404 93 40 Denmark 45 70131515 Finland 358 0 10 855 2100 France 0825 010 700 Germany 07031 464 6333 Ireland 1890 924 204 Israel 972 3 9288 504 544 Italy 39 02 92 60 8484 Netherlands 31 0 20 547 2111 Spain 34 91 631 3300 Sweden 0200 88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 0 118 9276201 Other European Countries www agilent com find contactus Revised October 1 2008 Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2009 Printed in USA March 1 2009 5989 9368ENUS of Agilent Technologies
4. 1000 1 30 kV passive probe e N2772A 20 MHz 1 2 kV differential probe requires 9V battery or N2773A power adapter e 1146A 100 kHz 100A AC DC current probe requires 9V battery Software and drivers IntuiLink toolbar connectivity software Downloadable free from www agilent com find intuilink Soft carrying case for 1000 Series Rackmount kit for 1000 Series Electronic instrument training kit 11 EN Agilent Email Updates www agilent com find emailupdates Get the latest information on the products and applications you select Agilent Direct www agilent com find agilentdirect Quickly choose and use your test equipment solutions with confidence Agilent g Open aa www agilent com find open Agilent Open simplifies the process of connecting and programming test systems to help engineers design validate and manufacture electronic products Agilent offers open connectivity for a broad range of system ready instruments open industry software PC standard 0 and global support which are combined to more easily integrate test system development LX www I xistandard org LXI is the LAN based successor to GPIB providing faster more efficient connectivity Agilent is a founding member of the LXI consortium Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2008 Printed in USA August xx 2008 5989 9368ENUS
5. 4 The bright crisp display on the 1000 Series oscilloscope and its wide viewing angle let you quickly identify your signal activity co When Setting 240ns Figure 5 Turning off the menu gives almost 25 more viewing area for your signals 106 Ans Figure 6 With True Zoom mode you can view a long record and the details of a zoom win dow simultaneously More capabilities Feel like you re using a much higher priced scope e 23 automatic measurements give you quick access to powerful functions e Unique to its class sequence mode allows easy debug with waveform recording playback and storage e Selectable band pass filtering eliminates unwanted signals e Advanced triggering makes it simple to capture and view elusive signals 23 automatic measurements All 1000 Series scopes come equipped with 23 automatic voltage time and frequency mea surements Press the Measure key to bring up the three you use most often or display all single channel measurements on the screen simultaneously Sequence mode for easier debug Record up to 1000 occurrences of a trigger event and then play them back to easily spot glitches or other anomalies for further examination Store the waveforms to internal or exter nal memory USB flash drive Digital filtering on waveforms Apply a real time digital filter of your choice to the source waveform to eliminate unwanted frequencies from your display Digital filtering selecti
6. at lab stations in demand 1000 Series solutions schools and universities For more information visit www agilent com find DSO1000A 2 More signal viewing See more of your signal more of the time e 20 kpts memory per channel up to 8 times more than competitive scopes means you can see more time and more detail on your signal A 5 7 inch diagonal color QVGA TFT LCD gives you a noticeably brighter and crisper waveform display e A wider viewing angle lets you see the display even when you re not right in front of the unit e True zoom mode means you can see the big picture and the details at the same time e Optionally switch off the menu display for almost 25 more viewing area Capture long time periods with high resolution All 1000 Series models provide up to 20 kpts per channel of convenient acquisition memory standard The scope will maintain high resolution acquisitions even at slower timebase set tings so you can see the details on your signals See your signals more clearly Every 1000 Series scope incorporates a bright crisp LCD color display 300 cd m7 You can quickly view your signal from almost any angle Unlike conventional scopes that always require menus to be on the entire 5 inch diagonal screen is available for waveform display as needed True Zoom mode for signal details and context Dual display and True Zoom shows your entire signal and zoomed in waveform details at the same time Figure
7. get your signal on screen fast with vertical horizontal and trigger controls auto matically adjusted for best signal display Performance characteristics Bandwidth 3dB 2 Real time sample rate Memory depth Channels Vertical resolution Vertical range DC gain accuracy Vertical zoom Maximum input voltage Dynamic range Time base range Selectable BW limit Horizontal modes Input coupling Input impedance Time scale accuracy DS01002A DSO1004A DC to 60 MHz DS01012A DS01014A DC to 100 MHz DS01022A DS01024A DC to 200 MHz 2 GSa sec half channel 1 GSa sec each channel 20 kpts half channel 10 kpts each channel DSO1002A DS01012A DS01022A 2 channels DSO1004A DSO1014A DS01024A 4 channels 8 bits 2 mV div to 10 V div 2 mV div to 5 mV div 4 0 full scale 10 mV div to 5 mV div 3 0 full scale Vertical expand CAT 300 Vrms 400 Vpk transient overvoltage 1 6kVpk 6 div DSO102xA 1 nsec div to 50 sec div DS0101xA 2 nsec div to 50 sec div DSO100xA 5 nsec div to 50 sec div 20 MHz Main Y T XY delayed zoom and roll DC AC and ground 1 MQ 1 in parallel with 18 pF 3 pF 50 ppm from 0 C to 30 C 50 ppm 2 ppm per C from 30 C to 45 C 5 ppm x years since manufacture 1 Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature 2 20 MHz when vertic
8. max Operating 0 C to 40 C non operating 20 C to 60 C Operating 90 RH at 40 C for 24 hr non operating 60 RH at 60 C for 24 hr Operating to 4 400 m 15 000 ft non operating to 15 000 m 49 213 ft Agilent class GP and MIL PRF 28800F class 3 random Agilent class GP and MIL PRF 28800F Normally only dry non conductive pollution occurs Occasionally a temporary conductivity caused by condensation must be expected Rated for indoor use only Ordering information Model number Description Price US list DSO1002A 60 MHz 2 ch DSO 1 200 DSO1004A 60 MHz 4 ch DSO 1 730 DSO1012A 100 MHz 2 ch DSO 1 500 DSO1014A 100 MHz 4 ch DSO 2 080 DS01022A 200 MHz 2 ch DSO 1 880 DSO1024A 200 MHz 4 ch DSO 2 410 Accessories included e Documentation CD e Power cord e Localized front panel overlay if language e 10 1 passive probe for each input option other than English is chosen channel 2 or 4 Optional accessories e N2738A Soft carrying case for 1000 Series e N2739A Rackmount kit for 1000 Series e N2740A Education training kit for 1000 Series includes training board USB cable and manual e U3000A Electronic instrument training kit Recommended probes e N2862A 150 MHz 10 1 passive probe standard with 60 MHz 100 MHz models e N2863A 300 MHz 10 1 passive probe standard with 200 MHz models e 10070C 20 MHz 1 1 passive probe e 10076A 250 MHz 100 1 4 kV passive probe e N2771A 50 MHz
9. mode Sturdy snap handle for easy _ 5 carrying S V4 Two USB host ports one on front M and one on rear facilitate saving A data to a USB flash drive and wu k enable quick firmware updates foasnre ay mis rim a Ai Fi ot ae ee TT E TE Aik m iihi CE E Wasa ooa va imna ean an e b te pa Ce ee 4 a aS USB device port for USBTMC remote PC control also allows easy printing to all PictBridge compatible printers Secure with a Kensington lock or looped cable More capabilities User friendly menu facilitates access to advanced features like mask test sequence mode and digital filtering Push button knobs enhance usability for example the Main Zoom knob zooms in on a particular section of waveform Push to toggle zoom on and off 77 Horizontal Measurement cursors can be placed manually or automatically MO er fe ame Trigger A m m weet 17 23 automatic measurements with a measure E all feature Comprehensive trigger functions including edge pulse width pattern composite video and alter nate channel 1 1 f 1 7A i 1 i 1 1 1 1 1 7 Four math functions for quick display x FFT More productivity Multi language interface support and online help for 11 languages Save up to 10 setups and waveform memories internally Default setup quickly returns the scope to a known starting point AutoScale to
10. al scale is set to lt 5 mV 3 Half channel is when only one channel of channel pair 1 2 or 3 4 is turned on Performance characteristics Acquisition modes Normal Averaging Sequence Peak detect Roll Interpolation Trigger coupling Trigger modes Force Edge Video Pulse width Alternate Trigger source Trigger sensitivity Cursor measurement Auto measurement Voltage Time Counter Display all measurements Math functions AutoScale Display Display persistence Display types Waveform update rate Save Recall internal Save Recall external Displays sampled data directly to the screen in real time Selectable from 2 4 8 16 32 64 128 or 256 Selectable 1 to 1 000 acquisition frames can be recorded played back and stored in the scope memory or external USB memory Captures high frequency glitches as narrow as 10 nsec when viewing signals at slow sweep speeds slower than 5 usec div Waveform display rolls from left to right Minimum horizontal scale setting is 50 msec div Sinx x AC DC LF reject Triggers immediately when front panel button is pressed Triggers on the positive or negative slope on any channel Triggers on NTSC PAL or SECAM video signals Triggers on pulse width greater than equal to or less than a specific time limit ranging from 20 nsec to 10 sec Triggers on two non synchronized active channels 2 channel models Ch 1 2 Ext Ext 5 AC Line edge only 4 channel models Ch 1
11. cale Quickly display any active signals and automatically set the vertical horizontal and trigger controls for optimal viewing with the press of the autoscale button This feature can be disabled or enabled for education customers Connectivity Built in USB host and device ports and free IntuiLink software make documentation and PC connectivity easy Store waveforms and setups to a USB flash drive easily update scope firmware and print to any PictBridge compatible printer ee ee ee Total 439 wfs Figure 10 Mask testing provides a quick pass fail comparison of an incoming signal to a test envelope you define 74 B ms Math Operate Source window Display 12 e Figure 11 Built in FFT enables easy spectral analysis on the time domain signal Le A i et T LA D i i 3 m Eor l Bi rot aaa F a wa Figure 12 Choose from 11 different languages for oscilloscope interface and help P4 PictBridge Agilent 1000 Series portable oscilloscopes Engineered to give you more scope than you thought you could afford More signal viewing Turn menu off for almost 25 gt more viewing area or set to turn Ww off automatically on timeout a DSO1024A 200MHz Agilent Technologies Gnallicscone 70887 Bright and crisp 5 7 inch color LCD display with wide angle viewing Acquisition memory bar shows full 20 kpts of memory and highlights portion displayed in zoom
12. e waveform can be saved and recalled using an internal volatile memory location for visual comparisons Setups STP saved and recalled Waveforms WFM saved and recalled CSV saved Reference waveforms REF saved and recalled for visual comparisons Images 8 bit BMP 24 bit BMP PNG saved 1 Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature Performance characteristics 1 0 Standard ports Max transfer rate USB flash drive compatibility Printer compatibility General characteristics Physical size Weight Probe comp output Kensington lock Power requirements Line range Power usage Environmental characteristics Ambient temperature Humidity Altitude Vibration Shock Pollution degree Indoor use 10 USB 2 0 compliant host ports on front and rear panel compatible with full speed USB flash drives USB device port for USBTMC remote PC control USB 2 0 full speed up to 12 Mb sec Most FAT formatted lt 2 GB or FAT32 formatted lt 32 GB flash drives PictBridge compliant printers via USB device port 12 78 W x 6 21 H x 5 08 D 32 46 cm W x 15 78 cm H x 12 92 cm D Net 3 03 kgs 6 68 Ibs Shipping 4 87 kgs 10 74 Ibs Frequency 1 kHz Amplitude 3 V Connection on rear panel for security a notch built into the chassis for cable loop locking mechanism 100 240 VAC 50 60 Hz 10 60 W
13. ons include low pass high pass band pass and band reject filters Frequency limits are selectable between 250 Hz and the full bandwidth of your oscilloscope Advanced triggering Triggering options for the 1000 Series include edge pulse width composite video pattern and alternate channel trigger modes These modes ensure that you can capture and view hard to find signal conditions Remote programming For remote instrument control over the built in USB interface utilize Agilent s 1 0 library or National Instrument s instrument drivers for the 1000 Series scope in your application The drivers take full advantage of industry accepted standards and are compatible with many ap plication development environments such as Agilent VEE Pro National Instrument s LabView and LabWindows CVI 2H Arnis a 1 2383 7HHz Figure 7 Display all single channel measurements on screen simultaneously segment 1000 Segment 2 Segment 1 Figure 8 Use sequence mode to record up to 1000 triggers and review in playback mode for anomalies Figure 9 Apply a low pass digital filter to transform the noisy waveform on channel 1 yellow into the clean waveform on channel 2 green More productivity Master the scope and get more answers in less time e Go no go mask testing automatically detects waveforms that deviate from the standard you set e Waveform math and FFT functions give you information instantly e Gra
14. phical user interface built in help system front panel overlay and user s manuals are available in your choice of 11 languages e Autoscale puts your signals on screen with the touch of a button e Built in USB host and device ports plus free IntuiLink software support PC connectivity and documentation e Store setups and waveforms in internal memory or on an external USB flash drive Standard 3 year warranty means your scope will be available when you need it Make fast go no go decisions Automatic pass fail mask testing comes as a standard feature on all 1000 Series scopes Acquire a golden waveform and define tolerance limits to create a test envelope Incoming signals will be compared to the allowable range and quickly flagged as pass or fail This is ideal for manufacturing or service where you need to make decisions quickly Waveform math and FFT Standard math functions include addition subtraction or multiplication of any two input chan nels and Fast Fourier Transform FFT with four user selectable windows Rectangle Hanning Hamming and Blackman Multi language interface Operate the oscilloscope in the language most familiar to you The built in help system graphical user interface optional front panel overlays and user s manual are available in eleven languages Choose from English Japanese simplified Chinese traditional Chinese Korean German French Spanish Russian Portuguese and Italian Autos

Download Pdf Manuals

image

Related Search

Related Contents

control de balizas tipo tb-75 manual de instrucciones  n° 120  Préparer et servir un repas aux enfants dans le respect des règles d  Fonte Duplo-Euro 80W Entrada AC/DC AL-3512  Service Manual  www.pce-iberica.es    Axor 5jet User's Manual  User's Manual - Research  

Copyright © All rights reserved.
Failed to retrieve file