1. Such regulations and or requirements may include for example handling of hazardous media and materials or provision use of personal protective equipment e In addition to this user manual issue any additional directives that may be required to meet spe cific operating requirements including supervision and reporting requirements e g directives re lating to work organization workflow and employed staff e Unless approved of expressly by the manufacturer do not modify the frequency inverter in any way including addition of attachments or retrofits e Only use the frequency inverter if the rated connection and setup values specified by the manu facturer are met e Provide appropriate tools as may be required for performing all work on the frequency inverter properly ACU STOV1 015V2 04 en 09 14 13 GO Bonfiglioli 2 10 Organizational measures 2 10 1 General e Train your staff in the handling and use of the frequency inverter and the machine plant as well as the risks involved e Use of any individual parts or components of the frequency inverter in other parts of the opera tor s machine plant is prohibited e Optional components for the frequency inverter must be used in accordance with their designated use and in compliance with the relevant documentation 2 10 2 Use in combination with third party products e Please note that BONFIGLIOLI VECTRON GmbH will not accept any responsibility for compatibility with third party
2. Bonfiglioli Vectron ACTIVE CUBE Application manual Safe Torque Off E ta y xq I Bonfiglioli ontrol and green solutio Wy Bonfiglioli Vectron TABLE OF CONTENTS 1 General information about the documentation 1 1 1 2 1 3 1 4 1 5 1 6 Instruction ManualS ssssssssssunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn 5 This COCUMENE ceeseeeeeneeeeeceeeeeaeeeseaseeeauoe se seeseenoaseeseooaseesenougeeseeoogsensnooanenses 6 Warranty and liability 2000 000 ieri 6 Obligation nT 7 Copyright ccccseeeeeeeseeeeeeceenensueennseeseeenouseeeenoauseeeeonaseuseeoaueeseeoaaeessenoaseesenons 7 co i ee ee ee eee 7 2 1 2 2 2 3 2 3 1 2 4 2 5 2 6 2 6 1 2 6 2 2 6 3 2 6 4 2 6 5 2 6 6 2 6 7 2 6 8 2 7 2 8 2 9 2 9 1 2 9 2 2 10 2 10 1 2 10 2 2 10 3 2 10 4 2 10 5 2 10 5 1 2 10 6 2 10 7 2 10 8 TerMinOlOGy 2 ecccceeseeeeeneseeeeeeeneeseeeeaseeesueeoaaeeeeeoeaseeseonaseeseeoageeeeeoogseessoogsenees 8 Designated use 1svsss0rerrs aaa nananana ni iene ieri iaia 9 MISUSE 20rrrrs ae ereee duain anadai auaa adaa aaa aadar adairean naiai 9 EXPlOSION ProtectioNi rrraiaiia wines AEA A EEDA ATARAR 9 Residual riSkS ssssssssnnunnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn 10 Safety and warning signs at frequency inverter ccsssseeessesseeeeeeeneeeeenes 10 Warning information and symbols u
3. Comply with the instructions of the manufacturer of the safety control equipment on the permissible contact load and any safeguards to be provided for the safety contacts The emergency stop device must comply with Standard EN ISO 13850 Ifa safety request e g emergency stop actuated or sensor signals that safety door is open is reset emergency stop unlocked safety door closed this alone shall not result in a restart of the drive Restart may only occur after the safety control device has been reset External safety control devices evaluate sensors Examples of contact sensors Emergency stop control device for stop in dangerous situations Position switch e g for monitoring slide doors safety grids or moving machine parts Examples of no contact sensors Light barriers e g for monitoring areas with dangerous movements Light curtains 7 3 External DC 24 V power supply During projection and installation of a DC 24 V supply connected to the frequency inverter comply with the following instruction This also includes supply of a safety control device the output of which is connected to a control input including STOA and STOB of the frequency inverter Use a suited SELV PELV voltage supply which rated voltage has to be DC 24 V 10 The largest overvoltage must not exceed DC 32 V in the case of a fault one fault safety The one fault safety has to be realized with an overvoltage protection of the mains s
4. This documentation was written in german language Other language versions are translated ACU STOV1 015V2 04 en 09 14 5 GO Bonfiglioli 1 2 This document The present documentation complements the operating instructions ACTIVE Cube ACU It contains additional safety information and requirements for the operation or ACTIVE Cube ACU in safety oriented applications Use in safety oriented machines shall be permissible only after this documenta tion has been read carefully and understood The applicable basic standards as well as application specific and specific national standards shall also be complied with the standards referred to in this manual shall also be complied with For this reason make sure you read the user manual carefully Compliance with the documentation is required to ensure safe operation of the frequen cy inverter BONFIGLIOLI VECTRON GmbH shall not be held liable for any damage caused by any non compliance with the documentation In case any problems occur which are not covered by the documentation sufficiently please contact the manufacturer 1 3 Warranty and liability BONFIGLIOLI VECTRON GmbH would like to point out that the contents of this user manual do not form part of any previous or existing agreement assurance or legal relationship Neither are they intended to supplement or replace such agreements assurances or legal relationships Any obligations of the manufacturer shall solely be based on t
5. chapter Special work specific safety instructions are provided before each safety relevant work step 2 1 Terminology According to the documentation different activities must be performed by certain persons with certain qualifications The groups of persons with the required qualification are defined as follows Operator This is the entrepreneur company who which operates the frequency inverter and uses it as per the specifications or has it operated by qualified and instructed staff Operating staff The term Operating Staff covers persons instructed by the Operator of the frequency inverter and assigned the task of operating the frequency inverter Qualified staff The term Qualified Staff covers staff who is assigned special tasks by the Operator of the frequency inverter e g installation maintenance and service repair and troubleshooting Based on their qualifi cation and or know how qualified staff must be capable of identifying defects and assessing func tions Qualified electrician The term Qualified Electrician covers qualified and trained staff who has special technical know how and experience with electrical installations In addition Qualified Electricians must be familiar with the applicable standards and regulations they must be able to assess the assigned tasks properly and identify and eliminate potential hazards Instructed person The term Instructed Person covers staff who was instructed and trained about in the
6. error is detected by the diagnosis function in oper ation status STO Enable Before the frequency inverter output stages are released Check if STOA and STOB are switched on less than 5 s after one another 5s monitoring If this is the case the release is prepared Diagnosis for error in stop paths STOA and STOB If no error is detected in the stop paths and release has been prepared the output stages are enabled 6 3 Diagnosis indicators The LEDs of the frequency inverter indicate if the safety function is activated properly LED green red Description Rotary field on motor Off Off No supply voltage unit is off No On On Initialization and self test No Flashing Off Operation mode No On Off Operating message Yes On Flashing Warning message in operation Yes Flashing _ Flashing Ready for operation and warning message No Off Flashing Fault message No Off On Error message can be acknowledged No ACU STOV1 015V2 04 en 09 14 25 GO Bonfiglioli 7 Requirements to be met by installation 7 1 Instructions on installation of safety equipment If work is to be carried out on live components it must be possible to disconnect the machine from mains supply by means of a main switch According to EN 61800 5 2 a fault exclusion can be considered with one of the following possibili ties o The conductor is installed permanently and in example protected against external damage wit
7. opening and improper interventions in the machine plant can lead to personal injury or material damage Repairs on the frequency inverters may only be carried out by the manufac turer or persons authorized by the manufacturer Check protective equipment regularly e Before performing any maintenance work the machine plant must be disconnected from mains supply and secured against restarting The five safety rules must be complied with 2 10 8 Final decommissioning Unless separate return or disposal agreements were made recycle the disassembled frequency in verter components e Scrap metal materials e Recycle plastic elements e Sort and dispose of other component materials Electric scrap electronic components lubricants and other utility materials must be treated as special waste and may only be disposed of by specialized companies D In any case comply with any applicable national disposal regulations as regards envi E amp Y ronmentally compatible disposal of the frequency inverter For more details contact the competent local authorities ACU STOV1 015V2 04 en 16 09 14 V Bonfiglioli Vectron 3 Safety I nstructions on Function Safe Torque Off STO The function Safe Torque Off STO is a functional safety provision i e it protects staff from damage provided that projecting installation and operation are performed properly This function does not disconnect the plant from power supply The safety
8. prevents a start of the motor According to EN 60204 1 STO must not be released during an impending endangerment Also comply with the instructions on external safety control equipment During commissioning check the safety function Select the dimensions of the safety application such that 14 mA input current is available for each of the inputs STOA and STOB If more than one ACTIVE Cube frequency inverters are connected to one safety control device the safety control device must provide sufficient power for all of them 26 ACU STOV1 015V2 04 en 09 14 xv Bonfiglioli 7 2 External Safety Control Equipment Safety control equipment upon request e g actuation of emergency stop or access to hazard area must trigger appropriate responses in order to protect people the machine and the environment They evaluate sensor signals or safely switch off dangerous states External safety control devices must meet the following requirements External safety control equipment and safety modules for control of the digital inputs STO must meet one of the following classifications to meet the classification of the ACU device o PLdaccording to EN ISO 13849 1 o SIL 2 according to IEC 61508 o Category 3 according to EN 954 1 o the whole installation meets these requirements The switching capacity of the safety control equipment must be designed for the maximum per missible limited output current of the DC 24 power supply
9. siriana 14 Unexpected Resta a 37 Validation seserinis 37 Warranty and liability eee 6 ACU STOV1 01SV2 04 en 09 14 C Bonfiglioli Bonfiglioli worldwide network Bonfiglioli Australia 2 Cox Place Glendenning NSW 2761 Locked Bag 1000 Plumpton NSW 2761 Tel 61 2 8811 8000 Fax 61 2 9675 6605 www bonfiglioli com au sales bonfiglioli com au Bonfiglioli Brazil Travessa Cl udio Armando 171 Bloco 3 CEP 09861 730 Bairro Assun o S o Bernardo do Campo S o Paulo Tel 55 11 4344 1900 Fax 55 11 4344 1906 www bonfigliolidobrasil com br bonfigliolidobrasil bonfiglioli com Bonfiglioli Canada 2 7941 Jane Street Concord Ontario L4K 4L6 Tel 1 905 7384466 Fax 1 905 7389833 www bonfigliolicanada com sales bonfigliolicanada com Bonfiglioli China 19D No 360 Pu Dong Nan Road New Shanghai International Tower 200120 Shanghai Tel 86 21 5054 3357 Fax 86 21 5970 2957 www bonfiglioli cn bdssales bonfiglioli com cn Bonfiglioli Deutschland Sperberweg 12 41468 Neuss Tel 49 02131 2988 0 Fax 49 02131 2988 100 www bonfiglioli de info bonfiglioli de Bonfiglioli Espa a TECNOTRANS BONFIGLIOLI S A Pol Ind Zona Franca sector C calle F n 6 08040 Barcelona Tel 34 93 4478400 Fax 34 93 3360402 www tecnotrans com tecnotrans tecnotrans com Bonfiglioli France 14 Rue Eug ne Pottier BP 19 Zone Industrielle de Moimont II 95670 Marly l
10. 00r0 cirie ieri 35 10 7 Error exclusion short circuit in the cabinet 11 2 0rrrra irene iii 36 Checklist Safety Function Test Report STO status diagnosis Index of Change ACU STOV1 015V2 04 en 4 09 14 xv Bonfiglioli 1 General information about the documentation The present documentation complements the operating instructions and the Quick Start Guide of the frequency inverter ACTIVE Cube ACU 1 1 Instruction manuals For better clarity the documentation is structured according to the customer specific requirements made on the frequency inverter Quick start guide The Quick Start Guide describes the basic steps required for mechanical and electrical installation of the frequency inverter The guided commissioning supports you in the selection of necessary parame ters and the configuration of the frequency inverter by the software Operating instructions The Operating Instructions describe and document all functions of the frequency inverter The param eters required for adapting the frequency inverter to specific applications as well as the wide range of additional functions are described in detail Application manual The application manual supplements the documentation for purposeful installation and commissioning of the frequency inverter Information on various subjects connected with the use of the frequency inverter is described specific to the application If you need a copy of the doc
11. Information of Risk Analysis and Risk Assessment 5 General Description of Safety Function 5 1 Integrated Safety Function 11vrs 200 rrresa aiar eee iee einen 20 5 2 Functional Safety 1110 200100rrrs carie e areren iii ieri 20 5 3 Classification the safety requirement 11 2200rrr a rrereeeiiiiie ieri 20 6 1 Two Channel Monitoring ceeeecneneeeeeeenenseeseaneeeeeeeneaeesseeogsenseeneneeneeneneee 22 6 2 Diagnosis function and enforced dynamizing 1110 2000rrrsieiere iena 24 6 3 Diagnosis iNdiCators 11s0 2 00 sr rr ses eeere ae areren eee iee iene eee 25 7 1 Instructions on installation of safety equipment 10 2 rese 26 7 2 External Safety Control Equipment 11 220rrrrsrereres eee eee 27 7 3 External DC 24 V power Supply 11 20000r0s e eee reni eee 27 7 4 DC 24 V Power supply by ACU ccssscseeeeeeseeeeeneeseeseeonaeeeeeenaseeseeneneeeeenonees 28 10 1 Direct Stop Stop Category O cccccseseeeeeseseeeeeneeseeseeonseeeseonasenseeoaseeeesnonees 30 10 2 Direct Stop with Feedback to PLC Stop Category 0 31 10 3 Direct Stop Stop Category 1 111 20000rrs rare rese eee 32 10 4 Direct Stop with Feedback to PLC Stop Category L rrr 33 10 5 Internal DC 24 V Supply Stop Category 1 rrrrr ieri 34 10 6 Group Stop Stop Category 1 1 111 1
12. Principles describes the infor mation required for risk assessment Risk assessment is effected according to the following criteria degree of injury serious minor frequency or duration of stay frequent seldom possibilities of avoidance hardly possible possible For defined risks the Standards EN ISO 13849 1 IEC 61508 or EN 954 1 can be used to accomplish a correct classification into Safety category SIL Safety Integrated Level or PL Performance Level These standards contain design principles for safety relevant parts of control systems In the case of the safety function Safe Torque Off the risk assessment must consider the fact that the motor will coast to a standstill in the case of an error Depending on the application a mechanical brake may be required Responsibility The Manufacturer shall be responsible for the safety of the machine risk analysis of hazards originating from the machine measures for reduction and elimination of the risks documentation of residual risk from the point of view of the manufacturer selection of suitable controller installation of protective equipment ergonomics documentation warning of remaining risks The operator of the machine is responsible for the safety of the application risk analysis of hazards originating from the use of the machine documentation of residual risk from the point of view of the operator safe operation and pr
13. TOA and STOB Different signal states on inputs STOA or STOB start the 5 second monitoring Within 5 seconds the same signal must be present of both inputs otherwise an error will be sig naled F1205 The function of external installation can be checked via the 5 second monitoring by actuating the protection device ACU STOV1 015V2 04 en 09 14 23 Gg Bonfiglioli Behavior of frequency inverter after start Initialization Monitoring for release request 5 second monitoring Preparation of release check of stop paths Release of frequency inverter Behavior of frequency inverter in the case of an error Switch off of IGBT in power output stage by disconnection of optocoupler supply voltage Suppression of control pulses of GBT Setting of error bit with possibility of transfer to overriding controller Setting of digital output for error message Release of digital input for error acknowledgement 6 2 Diagnosis function and enforced dynamizing The two stop paths are monitored by the frequency inverter every 32 ms If at least one of the two inputs S1IND STOA or S7IND STOB is switched off the pulse block is activated Additionally a 5 second monitoring cycle begins for the other stop path If this path is not stop within 5 s error F1205 is output The test required for monitoring the stop paths is performed by the frequency inverter automatically Via automated enforced dynamizing
14. The application circuit shows a drive control system according to EN ISO 13849 1 PL d IEC 61508 SIL 2 or EN 954 1 category 3 with a PLC connected via the field bus and safety module A PLC performs the process control of the frequency inverter and can start the drive profiles via commands which are communicated through the field bus If the protective device is actuated e g emergency stop switch the enable paths of the safety mod ule are interrupted At first the travel signal Clockwise is reset Then the motors are decelerated in a controlled way After a delay t the controller enable signal of the frequency inverters is interrupted via the disconnection of the control voltages from STOA and STOB and the integrated safe pulse block is activated Via the field bus the non safe feedback is transmitted to the PLC indicating that the drives have stopped Except for the terminals shown in the diagram no further terminals are required for connec tion The external DC 24 V supply must be dimensioned accordingly For each STOA amp STOB input 14 mA must be available Emergency stop device opened closed f Field bus Safety control equipment ACTIVE Acknowledgment Field bus _ connection ACTIVE hkm 1 r X310 Field bus _ ee Safety circuit Electrical cabinet STOA first shutdown path of the safety function STO STOB s
15. a Ville Tel 33 1 34474510 Fax 33 1 34688800 www bonfiglioli fr btf bonfiglioli fr Bonfiglioli India PLOT AC7 AC11 Sidco Industrial Estate Thirumudivakkam Chennai 600 044 Tel 91 0 44 24781035 24781036 24781037 Fax 91 0 44 24780091 24781904 www bonfiglioliindia com bonfig vsnl com Bonfiglioli Italia Via Sandro Pertini lotto 7b 20080 Carpiano Milano Tel 39 02 985081 Fax 39 02 985085817 www bonfiglioli it customerservice italia bonfiglioli it Bonfiglioli New Zealand 88 Hastie Avenue Mangere Bridge Auckland 2022 New Zealand PO Box 11795 Ellerslie Tel 64 09 634 6441 Fax 64 09 634 6445 npollington bonfiglioli com au Bonfiglioli Osterreich Molkereistr 4 A 2700 Wiener Neustadt Tel 43 02622 22400 Fax 43 02622 22386 www bonfiglioli at info bonfiglioli at Bonfiglioli South East Asia No 21 Woodlands indusrial park E1 02 03 Singapore 757720 Tel 65 6893 6346 7 Fax 65 6893 6342 www bonfiglioli com au sales bonfiglioli com sg Bonfiglioli South Africa 55 Galaxy Avenue Linbro Business Park Sandton Tel 27 11 608 2030 OR Fax 27 11 608 2631 www bonfiglioli co za bonfigsales bonfiglioli co za Bonfiglioli T rkiye Atat rk Organ ze Sanayi B lgesi 10015 Sk No 17 igli Izmir Tel 90 0 232 328 22 77 pbx Fax 90 0 232 328 04 14 www bonfiglioli com tr info bonfiglioli com tr Bonfiglioli United Kingdom Industrial Solutions Uni
16. a unit Triggering can be effected for example via a two channel contac tor control with two release circuits and redundant disconnection of the main current or via a sensor or emergency stop switch with two contacts and separate cable routing to the evaluation unit The stop paths are monitored cyclically every 32 ms Both stop paths are designed identically Via the digital inputs S1IND STOA and S7IND STOB two DC 24 V control voltages of a protection device are applied If the protection device is actuated the control voltages are interrupted and the pulse block is activated energy supply to the motor is switched off Disconnection is effected at a delay of less than 10 ms If the function STO is triggered the overriding controller has no more influence on the pulse block in the frequency inverter To restart the pulse block has to be reset and a release commanded by the operator or the superior PLC One single error will not result in a failure of the safety function 1 If the pulse block is set the controller release is reset If the pulse block is set no motor revolving field is generated ACU STOV1 01SV2 04 en 22 09 14 W Bonfiglioli Stop paths S1IND STOA S7IND STOB 3 HC PWM VD Diagnosis and monitoring Di Control unit Power unit The test required for monitoring is performed by the frequency inverter automatically If the test re s
17. assigned tasks and the potential hazards that might result from inappropriate behavior In addition instructed per sons must have been instructed in the required protection provisions protective measures the appli cable directives accident prevention regulations as well as the operating conditions and verified their qualification Expert The term Expert covers qualified and trained staff who has special technical know how and experience relating to frequency inverter Experts must be familiar with the applicable government work safety directives accident prevention regulations guidelines and generally accepted rules of technology in order to assess the operationally safe condition of the frequency inverter ACU STOV1 015V2 04 en 8 09 14 W Bonfiglioli 2 2 Designated use The frequency inverter is designed according to the state of the art and recognized safety regulations The frequency inverters are electrical drive components intended for installation in industrial plants or machines Commissioning and start of operation is not allowed until it has been verified that the ma chine meets the requirements of the EC Machinery Directive 2006 42 EC and DIN EN 60204 1 The frequency inverters meet the requirements of the low voltage directive 2006 95 EEC and DIN EN 61800 5 1 CE labeling is based on these standards Responsibility for compliance with the EMC Directive 2004 108 EC lies with the operator Frequency inverters are only availabl
18. ation of frequency inverters must not have access to the fre quency inverter Do not bypass nor decommission any protective facilities The frequency inverter may be connected to power supply every 60 s This must be considered when operating a mains contactor in jog operation mode For commissioning or after an emer gency switch off a non recurrent direct restart is permissible After a failure and restoration of the power supply the motor may start unexpectedly if the Auto Start function is activated If staff is endangered a restart of the motor must be prevented by means of external circuitry Before commissioning and the start of the operation make sure to fix all covers and check the terminals Check the additional monitoring and protective devices according to EN 60204 and ap plicable the safety directives e g Working Machines Act or Accident Prevention Directives ACU STOV1 01SV2 04 en 09 14 15 GO Bonfiglioli 2 10 7 Maintenance and service troubleshooting e Visually inspect the frequency inverter when carrying out the required maintenance work and inspections at the machine plant e Perform the maintenance work and inspections prescribed for the machine carefully including the specifications on parts equipment replacement e Work on the electrical components may only be performed by a qualified electrician according to the applicable rules of electrical engineering Only use original spare parts e Unauthorized
19. cuit emer X10 24V S30UT 2 La Electrical cabinet o Hi e N STOA first shutdown path of the safety function STO STOB second shutdown path of the safety function STO X210A X210B X10 Control terminals of the frequency inverter X310 Interface of communication module E20V DC 20 V voltage output or input for an external DC 24 V voltage supply Terminal X210A 2 Earth 20 V Earth 24 V ext S1IND S7IND Digital inputs S10UTD Digital output MFO1 Multi function output analog digital frequency signal 10VRef Reference voltage DC 10 V MFI1 Multi function input analog digital Terminal 210B 7 Earth 10 V X10 Relay output 4 Position switch displayed actuated tv time delay between signaling contact and shutdown contact ACU STOV1 01SV2 04 en 32 09 14 xv Bonfiglioli 10 4 Direct Stop with Feedback to PLC Stop Category 1 The application circuit shows a drive control system according to EN ISO 13849 1 PL d IEC 61508 SIL 2 or EN 954 1 category 3 with PLC and safety module A PLC performs the process control of the fre quency inverter and can start the drive profiles via commands If the protective device is actuated e g safety door open the enable paths of the safety module are interrupted At first the PLC is informed about the fact that the safety function has been triggered Then the PLC decelerates the motor in a controlled way by resetting the direction of rotation S2 or S3 Aft
20. d that all safety requirements are met e Additionally comply with the applicable laws regulations and directives of the country in which the frequency inverter is used Any additional guidelines and directives that may be required additionally shall be defined by the operator of the machine plant considering the operating environment 2 8 Operator s general plant documentation e In addition to the user manual the operator should issue separate internal operating instructions for the frequency inverter The user manual of the frequency inverter must be included in the user manual of the whole plant 2 9 Operator s operating staff s responsibilities 2 9 1 Selection and qualification of staff e Any work on the frequency inverter may only be carried out by qualified technical staff The staff must not be under the influence of any drugs Note the minimum age required by law Define the staff s responsibility in connection with all work on the frequency inverter clearly e Work on the electrical components may only be performed by a qualified electrician according to the applicable rules of electrical engineering e The operating staff must be trained for the relevant work to be performed 2 9 2 General work safety e In addition to the user manual of the machine plant any applicable legal or other regulations relating to accident prevention and environmental protection must be complied with The staff must be instructed accordingly
21. e at specialized dealers and are exclusively intended for commercial use as per EN 61000 3 2 No capacitive loads may be connected to the frequency inverter The technical data connection specifications and information on ambient conditions are indicated on the rating plate and in the documentation and must be complied with in any case 2 3 Misuse Any use other than that described in Designated use shall not be permissible and shall be consid ered as misuse For example the machine plant must not be operated e by uninstructed staff e while it is not in perfect condition e without protection enclosure e g covers e without safety equipment or with safety equipment deactivated The manufacturer shall not be held liable for any damage resulting from such misuse The sole risk shall be borne by the operator 2 3 1 Explosion protection The frequency inverter is an IP 20 protection class device For this reason use of the device in explo sive atmospheres is not permitted ACU STOV1 01SV2 04 en 09 14 9 Gg Bonfiglioli 2 4 Residual risks Residual risks are special hazards involved in handling of the frequency inverter which cannot be elim inated despite the safety compliant design of the device Residual risks are not obviously identifiable and can be a potential source of injury or health hazard Typical residual hazards include Electrical hazard Danger of contact with energized components due to a defect open
22. ecessary to wait until the frequency inverter has been charged and discharged Thus readiness of the machine for operation can be restored more quickly Regular electro mechanic equipment are wearing out through the usage of the STO functionality this kind of equipment is no longer necessary and mainte nance costs can be reduced Safe Torque Off Energy supply for the rotary field of the motor is interrupted the motor coasts to a standstill Used if monitoring for standstill is not required Accidental start of the motor is prevented No galvanic isolation of motor from frequency inverter DC link Traditional System Integrated System with ACU and usage of STO Mains Mains ACTIVE Cube Frequency inverter with integrated Safety function 1 1 lt Safe Torque Off Further advantages Contactors on motor side not required reduced installation requirements less components more space in electrical cabinet Simple realization with external safety control device The drive can be connected to power supply continuously communication and parameter configuration of the frequency inverter are maintained while the torque is disabled Easier machine approval because the safety function is certified via a type examination check ACU STOV1 015V2 04 en 09 14 21 Gg Bonfiglioli Triggering of function Safe Torque Off Safe Torque Off can be achieved by Intentional t
23. econd shutdown path of the safety function STO i Position switch displayed actuated tv time delay between signaling contact and shutdown contact ACU STOV1 015V2 04 en 09 14 35 Go Bonfiglioli 10 7 Error exclusion short circuit in the cabinet The application circuit shows a drive control system according to EN ISO 13849 PL d IEC 61508 SIL 2 or EN 954 1 category 3 with PLC and safety control equipment Safety control equipment with one enable path and interconnection line is implemented instead of safety control equipment with two enable paths Comply with the following conditions Safety control equipment and inverter have to be placed in the same cabinet Error exclusion in case of short circuit has to be ensured for wiring between safety control equip ment and inverter for example insulated conductor Blocking diodes have to be integrated into each path after separation of the STO inputs Emergency stop device opened closed Mains Safety control equipment Acknowledgment X210A ACTIVE Cube Safety circuit STOB ND Bess 3 Speed gt 0 Set value o MenA X10 ssourz Electrical cabinet 4 Position switch displayed actuated t Time delay between signaling contact and shutdown contact ACU STOV1 01SV2 04 en 36 09 14 xv Bonfiglioli 11 Checklist This list provides an overview of the require
24. ed covers or enclosures or im proper working on electrical equipment Danger of contact with energized components inside of the frequency inverter if no external discon nection device was installed by the operator Electrostatic charging Touching electronic components bears the risk of electrostatic discharges Thermal hazards Risk of accidents by hot machine plant surfaces e g heat sink transformer fuse or sine filter Charged capacitors in DC link The DC link may have dangerous voltage levels even up to three minutes after shutdown Danger of equipment falling down over e g during transport Center of gravity is not the middle of the electric cabinet modules 2 5 Safety and warning signs at frequency inverter e Comply with all safety instructions and danger information provided on the frequency inverter e Safety information and warnings on the frequency inverter must not be removed ACU STOV1 015V2 04 en 10 09 14 xv Bonfiglioli Vectron 2 6 Warning information and symbols used in the user manual 2 6 1 Hazard classes The following hazard identifications and symbols are used to mark particularly important information Identification of immediate threat holding a high risk of death or serious injury if not A avoided Identification of immediate threat holding a medium risk of death or serious injury if not avoided Identification of immediate threat holding a low risk of minor or moderate physical in
25. er a delay ty the controller enable signal of the frequency inverter is interrupted via the dis connection of the control voltages from STOA and STOB and the integrated safe pulse block is acti vated The safety module monitors the function of the switches S1 and S2 which are located outside of the electrical cabinet Safety installation opened closed Mains Safety control equipment Acknowledgment X210A ACTIVE Cube s uroxa_ spera X10 a s0un Safety circuit Set value Eletrical cabinet 4 Position switch displayed actuated t time delay between signaling contact and shutdown contact ACU STOV1 015V2 04 en 09 14 33 GO Bonfiglioli 10 5 Internal DC 24 V Supply Stop Category 1 The application example shows the minimum circuitry for ACTIVE cube frequency inverters for realiza tion of the safety function STO Safe Torque Off with an emergency stop switch in a common electri cal cabinet Supply of the safety control device is effected by the internal DC 24 V supply max 180 mA When the emergency stop switch is actuated the travel command Clockwise is reset first After a delay t the contacts on the safety switch interrupt the two enable paths STOA and STOB of the AC TIVE Cube frequency inverter and the integrated safety function is activated The delay time is set on the safety control device and must be selected acc
26. fely Wear and tear of the mechanical elements must be considered during projection for the operating states and indicated in the maintenance instructions Stop category 0 always has priority over stop category 1 ACU STOV1 015V2 04 en 09 14 29 Gio Bonfiglioli 10 1 Direct Stop Stop Category 0 The application example shows the minimum circuitry for ACTIVE cube frequency inverters for realiza tion of the safety function STO Safe Torque Off with an emergency stop device in a common electri cal cabinet If the emergency stop device with two stop channels according to EN ISO 13849 1 PL d IEC 61508 SIL 2 or EN954 1 Category 3 is actuated both stop paths STOA and STOB of the ACTIVE Cube fre quency inverter are interrupted and the integrated safety function with safe pulse block with SIL 2 according to EN 61800 5 2 is activated A non safe feedback to a process controller can be effected for example via a connected field bus If STO is requested the overriding controller has no more influence on the pulse block in the frequen cy inverter Terminal X210A 1 can be used for DC 24 V supply of the safety control unit Please 1 note the current capacity of the frequency inverter and the current requirements of the safety control device Mains Field bus Safety control equipment q ACTIVE S3IND efsano Li ICE Safety circuit 24V Electrical cabinet STOA first shutdow
27. function Safe torque off STO can be used to realize an Emergency Stop according to EN 60204 while the power supply is still active on the frequency inverter A provision must be provided for disconnecting the machine from power supply for maintenance work Improper installation of the safety technique can cause an uncontrolled starting of the drive This may cause death serious injuries and significant material damage Safety functions may only be installed and commissioned by qualified staff The Standard EN 60204 separates EMERGENCY SWITCH OFF and EMERGENCY STOP EMERGENCY SWITCH OFF means the electrical disconnection of the frequency invert er from the supply source An EMERGENCY SWITCH OFF can be realized by installing a switch disconnector in example EMERGENCY STOP provides the possibility to achieve a safe state of the frequency inverter while maintaining the supply voltage Depending on the application other components may be necessary to achieve a safe state in addition to Safe Torque Off STO of the frequency inverter An EMERGENCY STOP according to EN 60204 must be functioning in all operation modes of the application Resetting of an EMERGENCY STOP or an EMERGENCY SWITCH OFF must not result in uncontrolled starting of the drive The drive is started again when the function STO is no longer triggered In order to comply with EN 60204 it must be ensured by taking external measures that the drive does not
28. functions must be checked particularly during the inspection and documented in the inspection report Parameter settings shall be attached to the report Further documents shall be added as required depending on the machine Depending on the result of the risk analysis inspection reports of the regular inspections shall be is sued and signed by the inspector ACU STOV1 015V2 04 en 28 09 14 xv Bonfiglioli 10 Application Examples The following examples illustrate how the Safe Torque Off function works According to EN 60204 stop functions are divided in different categories By suitable safety control devices stop categories 0 and 1 can be realized in combination with the frequency inverter ACU Stop category 0 Stop by immediate disconnection of energy supply to the machine drive elements i e uncontrolled stop Stop category 1 Controlled stop where energy is still being supplied to the drive elements of the machine to perform the stopping operation Energy supply is stopped only after the drive has come to a standstill Stop functions must always have priority over start functions and must work properly in any operation mode Resetting of the stop function must not cause any dangerous state The mechanical elements must be dimensioned properly for the stop category used If for example a mechanical brake is applied in the case of fast rotating machines via stop category 0 this brake must be able to stop the machine sa
29. grated safety functions reduce the risk of personal damage in hazard areas and reduce instal lation requirements 5 2 Functional Safety The safety function of the control system must be ensured for normal trouble free operating sates as well as in the case of an error As a result of this requirement The safety function must be checked in case errors are present Possible methods include error tree analysis FMEA etc 5 3 Classification the safety requirement The integrated safety function Safe Torque Off of the ACU frequency inverter meets the following requirements up to Safety integrity level SIL 2 according to DIN EN 61508 for STO STO Safe Torque Off ac cording to EN 61800 5 2 of category 3 according to DIN EN 954 1 safe stop upto performance level d according to EN 13849 1 In the case of an error thanks to the safety function STO the frequency inverter does not supply energy to the motor which would cause a revolution or torque or a movement or force in the case of a linear motor Characteristic for the classification mentioned above Ifan error occurs the safety function is maintained By using appropriate safety control devices stop category 0 and stop category 1 according to EN 60204 can be achieved in the machine For safety control devices please refer to chapter 10 Stop category 0 Stop by immediate disconnection of energy supply to the machine drive elements i e uncontrolled s
30. h a cable duct or reinforcement o Single multi conductors are used o The conductors are situated in an electrical cabinet o The conductors are shielded independently and have grounding If applicable the requirements of EN 60204 1 have to be considered to install the con nectors correctly Protection against dirt is ensured if the ACTIVE Cube frequency inverters and safety control equipment is installed in electrical cabinets with high IP protection e g IP 54 If external forces act on the drive axis e g in the case of vertical axes Suspended loads or round axes with asymmetrical weight distribution mechanical brakes must be installed additional ly Only use voltage sources with safe disconnection SELV PELV according to VDE0100 Comply with the specifications in chapter 7 3 The ACTIVE Cube frequency inverters must not be supplied with pulsed signals Cross fault detec tion via pulsed signals cannot be used for this reason Errors can be excluded in the case of the ACTIVE Cube units because the terminal blocks for the STO function are physically separate from one another The signal cables between the safety control equipment and ACTIVE Cube must ei ther be physically separate from one another or suitable cross fault proof cables Comply with applicable EMC instructions mentioned in the operating instructions After installation check the safety function and error reaction and issue an acceptance report Interrupting the STO signals
31. he relevant purchase agreement which also includes the complete and solely valid warranty stipulations These contractual warranty provisions are neither extended nor limited by the specifications contained in this documentation The manufacturer reserves the right to correct or amend the specifications product information and omissions in these operating instructions without notice The manufacturer shall not be liable for any damage injuries or costs which may be caused by the aforementioned reasons In addition to that BONFIGLIOLI VECTRON GmbH excludes any warranty liability claims for any per sonal and or material damage if such damage is due to one or more of the following causes e inappropriate use of the frequency inverter e non compliance with the instructions warnings and prohibitions contained in the documentation e unauthorized modifications of the solar inverter e insufficient monitoring of parts of the machine plant which are subject to wear e repair work at the machine plant not carried out properly or in time e catastrophes by external impact and Force Majeure ACU STOV1 015V2 04 en 6 09 14 xv Bonfiglioli 1 4 Obligation This user manual must be read before commissioning and complied with Anybody entrusted with tasks in connection with the e transport e assembly e installation of the frequency inverter and e operation of the frequency inverter must have read and understood the user manual and in par
32. ju ry if not avoided Identification of a threat holding a risk of material damage if not avoided 2 6 2 Hazard symbols Symbol Meanin Symbol Meanin d General hazard A Suspended load Electrical voltage A 2 6 3 Prohibition signs Hot surfaces Symbol Meaning No switching it is forbidden to switch the machine plant assembly on 2 6 4 Personal safety equipment Symbol Meaning Q Wear body protection ACU STOV1 01SV2 04 en 09 14 11 Gg Bonfiglioli 2 6 5 Recycling Symbol Meaning LAY Recycling to avoid waste collect all E amp Y materials for reuse 2 6 6 Grounding symbol Symbol Meanin Ground connection 2 6 7 ESD symbol Symbol Meaning ESD Electrostatic Discharge can damage components and assemblies 2 6 8 Information signs Symbol Meaning 12 Tips and information making using the frequency inverter easier ACU STOV1 015V2 04 en 09 14 xv Bonfiglioli 2 7 Directives and guidelines to be adhered to by the operator The operator must follow the following directives and regulations e Ensure that the applicable workplace related accident prevention regulations as well as other ap plicable national regulation are accessible to the staff e An authorized person must ensure before using the frequency inverter that the device is used in compliance with its designated use an
33. liance with the applicable standards e Only install the frequency inverter in a suitable operating environment The frequency inverter is exclusively designed for installation in industrial environments e f seals are removed from the case this can result in the warranty becoming null and void 2 10 5 Electrical connections e The five safety rules must be complied with e Never touch live terminals The DC link may have dangerous voltage levels even up to three minutes after shutdown e When performing any work on with the frequency inverter always comply with the applicable national and international regulations laws on work on electrical equipment plants of the country when the frequency inverter is used e The cables connected to the frequency inverters may not be subjected to high voltage insulation tests unless appropriate circuitry measures are taken before e Only connect the frequency inverter to suitable supply mains ACU STOV1 015V2 04 en 14 09 14 2 xv Bonfiglioli 10 5 1 The five safety rules When working on in electrical plants always follow the five safety rules 1 2 3 4 5 2 Isolate Secure to prevent restarting Check isolation Earth and short circuit Cover or shield neighboring live parts 10 6 Safe operation During operation of the frequency inverter always comply with the applicable national and inter national regulations laws on work on electrical equipment plants Before co
34. ments to be met in installation commissioning and opera tion of the safety function Depending on the application additional requirements must be met Com plete this list according to your application Risk analysis was performed requires the use of the safety function Safe Torque Off requires category 3 according to the following classifications PL d or smaller according to EN ISO 13849 1 SIL 2 or smaller according to IEC 61508 Category 3 or smaller according to EN 954 1 considers the stopping behavior of the ACTIVE Cube frequency inverter permits coasting of the drive to a standstill or requires the installation of a mechanical brake considers the access time to the hazard area defines intervals for regular functional checks of the safety function Installation EMC instructions in the operating instructions considered The shield of the 24 V power supply was connected on both sides Emergency stop devices meet the following classifications PL d or smaller according to EN ISO 13849 1 SIL 2 or smaller according to IEC 61508 Category 3 or smaller according to ENn 954 1 Emergency Stop devices have a cross fault monitoring 2 channel connection or protected wir ing Itis ensured that resetting of the safety control device alone does not result in a restart of the drive Itis ensured that no voltage higher than DC 30 V can occur on the terminals of
35. mmissioning and the start of the operation make sure to fix all covers and check the terminals Check the additional monitoring and protective devices according to the applicable na tional and international safety directives During operation never open the machine plant Do not connect disconnect any components equipment during operation The machine plant holds high voltage levels during operation is equipped with rotating parts fan and has hot surfaces Any unauthorized removal of covers improper use wrong installation or operation may result in serious injuries or material damage Some components e g the heat sink or brake resistor may be hot even some time after the ma chine plant was shut down Don t touch any surfaces directly after shutdown Wear safety gloves where necessary The frequency inverter may hold dangerous voltage levels until the capacitor in the DC link is dis charged Wait for at least 3 minutes after shutdown before starting electrical or mechanical work on the frequency inverter Even after this waiting time make sure that the equipment is deener gized in accordance with the safety rules before starting the work In order to avoid accidents or damage only qualified staff and electricians may carry out the work such as installation commissioning or setup In the case of a defect of terminals and or cables immediately disconnect the frequency inverter from mains supply Persons not familiar with the oper
36. n path of the safety function STO STOB second shutdown path of the safety function STO X210A X210B X10 Control terminals of the frequency inverter X310 Interface of communication module E20V DC 20 V voltage output or input for an external DC 24 V voltage supply Terminal X210A 2 Earth 20 V Earth 24 V ext S1IND S7IND Digital inputs S10UTD Digital output MFO1A Multi function output analog digital frequency signal 10VRef Reference voltage DC 10 V MFI1A Multi function input analog digital Terminal 210B 7 Earth 10 V X10 Relay output ACU STOV1 015V2 04 en 30 09 14 W Bonfiglioli 10 2 Direct Stop with Feedback to PLC Stop Category 0 The application circuit shows a drive control system according to EN ISO 13849 1 PL d IEC 61508 SIL 2 or EN 954 1 category 3 with PLC and safety module A PLC performs the process control of the fre quency inverter and can start the drive profiles via commands If the protective device is actuated e g safety door open the enable paths of the safety module are interrupted As a result the controller enable signal of the frequency inverter is interrupted via the disconnection of the control voltages from STOA and STOB and the integrated safe pulse block is acti vated The safety module monitors the function of the switches S1 and S2 which are located outside of the electrical cabinet Safety installation opened closed 5 Mains n S1 Safety control e
37. ns supply Even if the motor control is deactivated and the motor is coasting to a standstill or has already stopped high voltages may still be present on the motor terminals Before working e g maintenance on live parts the machine must always be discon nected from mains supply main switch This must be documented on the machine When the function Safe Torque Off is triggered the motor is not isolated from the DC link of the frequency inverter High voltage levels may be present at the motor Do not touch live terminals Permanent magnet synchronous motors PMSM must be operated only up to the synchronous speed PMSM cannot be operated above the synchronous speed be cause the trigger of the STO function can lead to the destruction of the power stage Approved Devices All ACU devices of sizes 1 to 7 are approved for applications with functional safety according to this ma nual For ACU of size 8 the certification of the function Safe Torque Off is in preparation The information of the size you can refer to the operating manual and the Quick Start Guide 18 ACU STOV1 015V2 04 en 09 14 xv Bonfiglioli 4 Information of Risk Analysis and Risk Assessment According to the Directive on Machinery 98 37 EC the manufacturer of a machine is obliged to carry out a risk analysis in order to identify the hazards related to the machine The Standard EN 14121 1 Safety of machinery Risk assessment
38. ording to the application The delay time is set on the safety control device and must be selected according to the application The set delay time has to be higher than the shut down time A non safe feedback to a process controller can be effected for example via a connected field bus If STO is requested the overriding controller has no more influence on the pulse block in the frequen cy inverter Safety installation Field bus Safety control equipment ACTIVE BEE sano 7 E Acknowledgment Field bus _ connection fafon ejmen X10 Safety circuit 24V Electrical cabinet STOA first shutdown path of the safety function STO STOB second shutdown path of the safety function STO X210A X210B X10 Control terminals of the frequency inverter X310 Interface of communication module E20V DC 20 V voltage output or input for an external DC 24 V voltage supply Terminal X210A 2 Earth 20 V Earth 24 V ext S1IND S7IND Digital inputs S10UTD Digital output MFO1 Multi function output analog digital frequency signal 10VRef Reference voltage DC 10 V MFI1 Multi function input analog digital Terminal 210B 7 Earth 10 V X10 Relay output 4 Position switch displayed actuated tv time delay between signaling contact and shutdown contact ACU STOV1 015V2 04 en 34 09 14 xv Bonfiglioli 10 6 Group Stop Stop Category 1
39. otection of operating staff barriers instruction of operating staff etc Selection of safety function Risk analysis and risk assessment for machine standards EN 12100 1 EN 12100 2 and EN 14121 1 Risk reduction by machine design If not possible by design risk reduction by protective equipment Identification of safety requirements Selection of category of safety function PL d according to EN ISO 13849 1 SIL 2 according to IEC 61508 Category 3 according to EN 954 1 The Standard EN954 1 was replaced by the legislator with the standard EN ISO 13849 1 ACU STOV1 015V2 04 en 09 14 19 GO Bonfiglioli 5 General Description of Safety Function 5 1 Integrated Safety Function Electronic protection systems are integrated in the drive control system and perform safety functions in order to minimize or eliminate hazards caused by functional errors of machines The integrated safety functions replace time consuming and expensive installation of external safety components The safety function can be requested or triggered by an error In hazard areas setup work or work for elimination or errors may be required where the safety func tion is not to be activated by isolating protection devices such as mains contactors or motor contac tors Here the additional safety function may be used STO can be used as an alternative to mains or motor contactors which can be omitted dependent on the application The inte
40. products e g motors cables or filters e In order to enable optimum system compatibility BONFIGLIOLI VECTRON GmbH office compo nents facilitating commissioning and providing optimum synchronization of the machine plant parts in operation e If you use the frequency inverter in combination with third party products you do this at your own risk 2 10 3 Transport and Storage e The frequency inverters must be transported and stored in an appropriate way During transport and storage the devices must remain in their original packaging e The units may only be stored in dry rooms which are protected against dust and moisture and are exposed to little temperature deviations only The requirements of DIN EN 60721 3 1 for storage DIN EN 60721 3 2 for transport and labeling on the packaging must be met e The duration of storage without connection to the permissible nominal voltage may not exceed one year 2 10 4 Handling and installation e Do not commission any damaged or destroyed components e Prevent any mechanical overloading of the frequency inverter Do not bend any components and never change the isolation distances e Do not touch any electronic construction elements and contacts The frequency inverter is equipped with components which are sensitive to electrostatic energy and can be damaged if handled improperly Any use of damaged or destroyed components will endanger the ma chine plant safety and shall be considered as a non comp
41. quipment X210A ACTIVE pi Acknowledgment Cube 6 mena_ X10 Set value 24V Feedback Eletrical cabinet 4 Position switch displayed actuated ACU STOV1 015V2 04 en 09 14 31 Go Bonfiglioli 10 3 Direct Stop Stop Category 1 The application example shows the minimum circuitry for ACTIVE cube frequency inverters for realiza tion of the safety function STO Safe Torque Off with an emergency stop device in a common electri cal cabinet When the emergency stop device is actuated the travel command Clockwise is reset first After a delay t the contacts on the safety switch interrupt the two enable paths STOA and STOB of the AC TIVE Cube frequency inverter and the integrated safety function is activated The delay time is set on the safety control device and must be selected according to the application The set delay time has to be higher than the shut down time A non safe feedback to a process controller can be effected for example via a connected field bus If STO is requested the overriding controller has no more influence on the pulse block in the frequen cy inverter Safety installation Mains Field bus Safety control equipment pd STA I afea D D ACTIVE Cube Acknowledgment Start CW 6 s41ND_ Field bus _ connection r _ S6IND LEESNET Safety cir
42. riggering during operation in order to stop a drive and safely prevent restarting e g for maintenance work on a machine Triggering by actuation of an emergency stop switch or monitoring of protective systems e g safety door Detection of an error The drive may only start again after the error has been acknowledged and eliminated Actuation of safety relay Safe Torque Off Detection of an error through self diagnosis Application example The danger zone near a transport conveyor is monitored by a light grid If anybody enters the danger zone the light grid is interrupted The DC 24 V supply for the digital inputs STO of the function Safe Torque Off is switched off and the frequency inverter output stage is disabled The drive coasts to a standstill Disconnection from mains supply is not necessary Communication via field bus or address ing via the terminals is still possible An external brake which stops the motor can be addressed 6 1 Two Channel Monitoring The STO function Safe torque off is realized via two channels in the frequency inverter redundant design Via two redundant monitored stop paths with no voltage release STOA and STOB the fre quency inverter is switched off safely even if an error occurs and the control voltage fails at the same time Thus the drive is stopped safely if an error occurs An error is identified and can then be re paired e g by replacing of
43. sed in the user manual s sssss 11 Hazard Classes ea 11 Hazard SyMDOl Sciencia ia ei dei riga 11 ProhibItioh SIGNS carie ie e 11 Personal safety equipment aaa 11 RECYGIINOt ar ea a aaa 12 Gro unding Symboll pipa lai iaia 12 ESD SYMbOlki aria ie iaia aa 12 Informationisighs riali 12 Directives and guidelines to be adhered to by the operator 13 Operator s general plant documentation cccsssseeeeeneseeeeenenseeseneneeenenens 13 Operator s operating staff s responsibilities ccccssseeessesseeeeeseeeneeees 13 Selection and qualification of Staff 0 i i iii 13 General work Safety iciiiscidastoaiiekitagerdedshenetdaanideliaatiendauatianen iii 13 Organizational Measures 2 sr vr a ereree aeree iii eee 14 Generalo iinoa iii 14 Use in combination with third party prodUctSs ii 14 Transport and Storage EEEE EEEE laa 14 Handling and installation asic irreale alan aaa Rea 14 El ctricall COMNECHOMNS ianiai iaia 14 The TIVE Safety TUleS c ciii e oa 15 Safe operatio Msanii aaa a eel alain hatha 15 Maintenance and service troubleshooting i 16 Final decommissioningi s isa iatale ali aaa aa 16 3 Safety Instructions on Function Safe Torque Off STO 3 1 Approved Devices i scssccsesacsssstnsesadsesscesestesssacedsrcesestenuseinsessuanssenvasdecesseanasss 18 ACU STOV1 015V2 04 en 09 14 GS Bonfiglioli 4
44. start without prior confirmation Without a mechanical brake the drive might not stop immediately but coast to a standstill If this may result in personal or material damage additional safety measures must be taken If persons may be endangered after disconnection of the motor control by STO ac cess to the hazard areas must be prevented until the drive has stopped Check the safety function at regular intervals according to the results of your risk assessment BONFIGLIOLI VECTRON recommends that the check is performed after one year at the latest The STO function is one fault fail safe No single fault or component failure can cause a disabled drive to produce motor shaft torque Only in extremely unlike combinations of component faults the motor shaft could move jerky with sudden acceleration max imum 180 number of pole pairs for example jerky movement of 90 for 4 pole mo tor 180 2 and produce torque It must be checked if this behavior can cause a dangerous machine movement If the STO function is used the special safety installation and instructions on use instructions shall be complied with Comply with the Application manual Safe Torque Off STO especially when the de scribed safety relevant function is used ACU STOV1 015V2 04 en 09 14 17 GX Bonfiglioli 3 1 A After disconnection of an external DC 24 V power supply the DC link of the frequency inverter is still connected to mai
45. t 7 Colemeadow Road North Moons Moat Redditch Worcestershire B98 9PB Tel 44 1527 65022 Fax 44 1527 61995 www bonfiglioli com uksales bonfiglioli com Mobile Solutions 3 7 Grosvenor Grange Woolston Warrington Cheshire WA1 4SF Tel 44 1925 852667 Fax 44 1925 852668 www bonfiglioli co uk mobilesales bonfiglioli co uk Bonfiglioli USA 3541 Hargrave Drive Hebron Kentucky 41048 Tel 1 859 334 3333 Fax 1 859 334 8888 www bonfiglioliusa com Bonfiglioli Vietnam Lot C 9D CN My Phuoc Industrial Park 3 Ben Cat Binh Duong Province Tel 84 650 3577411 Fax 84 650 3577422 www bonfiglioli vn salesvn bonfiglioli com GS Bonfiglioli power control and green solutions Bonfiglioli has been designing and developing innovative and reliable power transmission and control solutions for industry mobile machinery and renewable energy applicacations since 1956 Bonfiglioli Riduttori S p A tel 39 051 647 3111 COD VEC 541 R3 ACU STOV1 01SV2 04 en Via Giovanni XXIII 7 A fax 39 051 647 3126 40012 Lippo di Calderara di Reno bonfiglioli bonfiglioli com Bologna Italy www bonfiglioli com
46. the control elec tronic unit voltage resistance The protection against unexpected restart is set up Commissioning Functional check of safety function performed Wiring of safety components checked Acceptance report issued Operation The safety function is checked regularly ACU STOV1 01SV2 04 en 09 14 37 Gg Bonfiglioli 12 Safety Function Test Report The concept relating to the safety function STO Safe Torque Off described in this manual was as sessed and certified by Berufsgenossenschaftliches Institut f r Arbeitsschutz Trade Association Insti tute for Work Safety Test institute Institut f r Arbeitsschutz der Deutschen Gesetzlichen Unfallversi cherung Test report no _ 200622803 Test sample Frequency inverter of ACTIVE Cube series concept inspection Basis of test DIN EN 61508 Parts 1 7 2002 2005 as far as applicable DIN EN ISO 13849 2 2003 as far as applicable EN 13849 1 2006 11 DIN EN 954 1 1997 03 DIN EN 62061 DIN EN 61800 5 1 IEC 61800 5 2 2007 DIN EN 61800 3 Assessment Due to the realized error tolerance and the measures for error management error prevention and error identification the pre sented concept meets the requirements up to safety integrity level SIL 2 according to DIN EN 61508 category 3 according to DIN EN 954 1 as well as performance level d according to EN 13849 1 13 STO status diagnosis The act
47. the stop paths are checked for errors If the test result is nega tive the frequency inverter cannot be switched on anymore and error F1201 is signaled Starting is possible again only after the error has been repaired and the next diagnosis cycle has been completed successfully ACU STOV1 015V2 04 en 24 09 14 W Bonfiglioli Sequence of release and monitoring states depending on signals on control inputs STOA and STOB STOA AA E TIVE STOB M UOI ANTTTTTTTZZZ Diagnosis I I L J J I I ok ok ok ok ok ok ok ok fault ok fault fault Diagnosis nable__TT_OA__LLRh TCVOTOUQJOUQ S5 TThThh Le Monitoring loli 2 3 ol1 2 4 Diagnosis fault For gt 32 t ms STOA l T L___ STOB J J l l Diagnosis ok ok ok Diagnosis Enable T Lo 4 lolil 2 3 l 4 o0 5 s monitioring Monitoring moe 32 304 352 5260 5308 ums Monitoring states 0 Monitoring of Enable Actuation 3 Actuation of STO 1 Preparation Enable 4 Fault 2 Enable Diagnosis fault Only if 2 consecutive faults are recognized the monitoring function reports a fault 5 s Monitoring Checks if both inputs STOA and STOB are switched on within 5 s from each other In order to achieve robust operation and for example exclude electromagnetic interference in the signal assessment of the diagnosis function the diagnosis is repeated when an error is detected The frequency inverter is switched over only if another
48. ticular the safety instructions in order to prevent personal and material losses 1 5 Copyright In accordance with applicable law against unfair competition this user manual is a certificate Any copyrights relating to it shall remain with BONFIGLIOLI VECTRON GmbH Europark Fichtenhain B6 47807 Krefeld Germany These user manual is intended for the operator of the frequency inverter Any disclosure or copying of this document exploitation and communication of its contents as hardcopy or electronically shall be forbidden unless permitted expressly Any non compliance will constitute an offense against the copyright law dated 09 September 1965 the law against unfair competition and the Civil Code and may result in claims for damages All rights relating to patent utility model or design registration reserved 1 6 Storage The documentation form an integral part of the frequency inverter It must be stored such that it is accessible to operating staff at all times In case the frequency inverter is sold to other users this user manual must also be handed over ACU STOV1 015V2 04 en 09 14 7 GO Bonfiglioli 2 General safety instructions and information on use The chapter General safety instructions and information on use contains general safety instructions for the Operator and the Operating Staff At the beginning of certain main chapters some safety in structions are included which apply to all work described in the relevant
49. top Stop category 1 Controlled stop where energy is still being supplied to the drive elements of the machine to perform the stopping operation Energy supply is stopped only after the drive has come to a standstill Note that the drive may not stop immediately but coast to a standstill If no mechanical brake is in stalled or a defective brake may involve a risk further protective measures in example tumbler are to be taken ACU STOV1 015V2 04 en 20 09 14 W Bonfiglioli 6 Description of ACTI VE Cube Safety Function The frequency inverters of the ACU series of devices feature the integrated safety function Safe torque off STO In the case of an error or if requested the power semiconductors of the frequency inverter will be switched off After this the frequency inverter does not supply energy to the drive which would cause a revolution or a torque or a movement or force in the case of a linear drive Mains voltage is still present The function STO can be used for example for safe stopping in the case of a dangerous situation or for maintenance work on the machine If an error occurs the machine can still be or remain switched off safely Unlike shut down via mains contactors or motor contactors the integrated safety function enables easy combination of drives in a machine to form functional groups The Safe Torque Off can be lim ited to certain plant areas in this way Another advantage is the fact that it is not n
50. top Category 1 1 Direct Stop 32 1 Direct Stop with Feedback to PLC 33 3 Internal DC 24 V supply 34 A Group Stop 35 Approved Devices s es 18 CIECHI eolie 37 Classification the safety requirement 20 Cna T DG FAV Supply essnee 27 DecommiIssioning ie 16 Description of ACTIVE Cube Safety RINO 21 Desisiatedase rina 9 Diagnosis TNC GU alari 24 Directive on Machinery 19 Electrical connections 14 Enforced dynamizing 24 Fault exclusion saint 26 General information about the documentation lee 5 JnstallatiOn siiccscicpecessctssanssdipcedsacedentautaccden 14 Requirement 26 Instruction manuals 5 Integrated Safety Function 20 Norm EN ISO 13850 27 Niue 27 40 bill 19 Power supply External DC 24 Vi 27 Internal DC 24 V by ACU 28 Risk AMan 19 Risk Assessment ila 19 Safe torque off sorse 17 Safety Generalean aaa 8 Safety Control Equipment External tie inaani 27 Safety Function TESE REPONt cirie 38 Two Channel Monitoring 22 SELV spl ra 27 Sl lara 16 Deemer AAA RNA 19 Standard EN ISO 13849 1 cccccseseceeeeeeeeeeees 19 VEC G15 08 5 riiinig 19 Standard EN SO 12100 aa 19 Standard EN 61300 5 2 iic iii 26 Standard EN 6020481 on scccctsssccatens ii 26 OT ae Tee ene O RR I 14 Test ROD OM esas cheers nane 38 Transporft
51. ual value STO state 277 can be used for an extended diagnosis of the two inputs STOA and STOB The states of the inputs are displayed bit coded 0 1 Input STOA missing 1 2 Input STOB missing 2 4 Input STOA switch off 3 8 Input STOB switch off 4 16 Timeout STOA 5 32 Timeout STOB 6 64 Diagnosis fault 7 127 Frequency Inverter fault error 38 ACU STOV1 01SV2 04 en 09 14 14 xv Bonfiglioli Index of Change ACU STOV1 01SV2 04 General and Safety instructions adapted to actual Bonfiglioli Vectron documentations information in chapter 3 according to EN 60204 revised ACU STOV1 01SV2 03 Clarification of Emergency stop and emergency switch off in chapter 1 1 of the English version Note for transition period of EN954 1 in chapter 2 updated ACU STOV1 01SV2 02 Terminal designation of relay output X10 changed ACU STOV1 00SV2 02 New Application example Fault exclusion Short circuit in electrical cabinet Application examples 8 2 and 8 4 changed to display the usage of the digital output more precise ACU STOV1 00SV2 01 Different supplements and more detailed descriptions ACU STOV1 00SV1 01 Changed DC 24 V into DC 24 V and DC 30 V into DC 30 V ACU STOV1 00SV1 00 First issue ACU STOV1 01SV2 04 en 09 14 39 Gg Bonfiglioli 15 Index Application example STO Error eXCIUSION i 36 Stop Category 0 L Direct Stop isanne 30 2 Direct Stop with Feedback to PLC 31 S
52. ults negative the frequency inverter cannot be switched on anymore Starting is possible again only after the error has been repaired and the next test has been completed successfully Truth table In the truth table the states of the safety relevant inputs STOA and STOB for activation and deactiva tion of the safety function STO are listed STOA STOB Description of state 0 0 Safety function Safe Torque Off STO has been triggered The frequency inverter signals no error in STO function STO is triggered Monitoring for error in frequency inverter or ex i 1 ternal circuitry 5 second monitoring After 5 seconds an error is signaled 1 o 9 1 1 STO is not triggered Release for operation 5 second monitoring It will be checked if the two inputs STOA or STOB are switched on within an interval of less than 5 sec for requesting the release of the frequency inverter output stages If function STO is triggered by removing one of the signals from inputs STOA or STOB the status changes to STO triggered Now the unit waits that both inputs are switched off If this has not been done within 5 s after occurrence of this state an error is triggered 5 second monitoring If during operation an error is detected the output stage is switched off the release is reset 0 and the frequency inverter signals an error This status can only be left by switching off 0 the two release inputs S
53. umentation or additional information contact your local representative of BONFIGLIOLI The present documentation was prepared with great care and it was subjected to extensive and re peated reviews For reasons of clarity it was not possible to include all details of all types of the prod uct in the documentation Neither was it possible to consider all conceivable installation operation or maintenance situations If you require further information or if you meet with specific problems which are not dealt with in sufficient detail in the documentation contact your local BONFIGLIOLI agent We would also like to point out that the contents of this documentation do not form part of any pre vious or existing agreement assurance or legal relationship Neither are they intended to supplement or replace such agreements assurances or legal relationships The manufacturer s obligations are exclusively specified in the relevant purchase contract This contract also contains all and any warran ty regulations which may apply to the relevant scope of supply These contractual warranty provisions are neither extended nor limited by the specifications contained in this documentation The manufacturer reserves the right to correct or amend the specifications product information and omissions in these operating instructions without notice The manufacturer shall not be liable for any damage injuries or costs which may be caused by the aforementioned reasons
54. upply overvoltage protection OVP with limiting the output voltage to a maximum of DC 32 V or an external wiring like a Crowbar An adequate overvoltage category of the voltage supply has to be ensured ACU STOV1 015V2 04 en 09 14 27 Gg Bonfiglioli 7 4 DC 24 V Power supply by ACU You can use terminal X210A 1 in order to supply a safety control device Only use the power supply for the device connected to the frequency inverter Other safety control devices must not be con nected The maximum output current is 180 mA The connected device must not have higher current requirements 8 Requirements to be met in operation During operation the projected and commissioned machine components must not be changed If the machine is modified a new acceptance inspection is required Check the safety function at regular intervals The test intervals are to be determined according to the risk analysis However the check should be performed once every year at the latest 9 Requirements to be met by acceptance inspection The acceptance inspection of the safety function is ordered by the manufacturer of the machine The inspection acceptance shall be performed by a properly qualified person The result of the inspection is to be documented and must be signed by the inspector Each safety function must be documented in detail in this report The inspections also include the machine documentation including its safety functions The safety