Home
Ice Range - Dome Cameras User Guide
Contents
1. DEDICATED MICROS Dedicated Micros Ltd 1200 Daresbury Park Daresbury Cheshire WA4 4HS UK Dedicated Micros Europe Neckarstrafle 15 41836 H ckelhoven Germany Dedicated Micros France 9 13 rue du Moulinet 75013 Paris France Dedicated Micros Slovenia Delavska cesta 26 4208 Sencure Slovenia Dedicated Micros Benelux Joseph Chantraineplantsoen 1 3070 Kortenberg Belgium Dedicated Micros USA 14434 Albemarle Point Place Suite 100 Chantilly Virginia 20151 USA Dedicated Micros USA 23456 Hawthorne Blvd Suite 100 Torrance CA 90505 USA Dedicated Micros Australia PTY 5 3 Packard Avenue Castle Hill NSW 2154 Australia Dedicated Micros Asia PTY 16 New Industrial Road 403 03 Hudson Techno Centre Singapore 536204 Dedicated Micros Middle East Building 12 Suite 302 P O Box 500291 Dubai Internet City Dubai United Arab Emirates Dedicated Micros Malta Ltd BLB017 Bulebel Industrial Estate Zejtun ZTNO8 Malta TCE MI I ICED E1 0
2. The DIP switches are located on the camera s circuit board Ip Switches E White indicates default switch position Backlight Compensation The Backlight Compensation BLC feature compensates for back lit scenes by enhancing objects in the centre of the scene which would previously have been in silhouette Select ON or OFF using the BLC switch Default is OFF AGC Automatic Gain Control The Automatic Gain Control AGC feature can improve picture quality when levels of illumination are low Select ON or OFF using the AGC switch For most applications the AGC feature should be ON and is therefore the default setting Electronic lris The Electronic Iris El feature compensates for excessive light levels by automatically adjusting the shutter speed For auto iris lenses the El should be set to OFF For manual lenses El should be ON Line Lock Choose INT internal or LL adjustable The LL setting allows 180 phase adjustment via the two LL Phase Advance Retard buttons Default is LL Pressing both buttons simultaneously will reset LL to the factory default setting The LL setting can be adjusted using the LL potentiometer available on some versions of this product LLATI Dedicated Micros 02007 Day Night DN Versions only This switch sets the light level at which the camera automatically switches between day and night oper
3. EM DEDICATED MICROS Dome Cameras DM ICED BH39 DM ICED CMH39 B DM ICED CMU39 DM ICED CMU39 N DM ICED DNU39 B DM ICED DUM DM ICED CMH39 DM ICED CMH39 N DM ICED CMU39 B DM ICED DNU39 DM ICED DNU39 N Contents Introduction eiii 3 Important Safeguards 4 Installation 6 Controls and Switches 8 DIP SWINGS iet etaed dede 8 APPENADG aaa Ee 11 Quicksta ehh oda cierre er peter dade 12 jn Ntn 15 Whilst every attempt is made to ensure these manuals are accurate and current Dedicated Micros reserve the right to alter or modify the specification of the machine described herein without prejudice Dedicated Micros 2007 Introduction These instructions cover ICE series fixed dome cameras Read all of these instructions Use them to install your camera and have them available for its lifetime If you have any problems contact your agent Models DM ICED BH39 Mono high resolution 570 TVL 1 3 SuperHAD CCD 0 07 lux at F1 2 DM ICED CMH39 Colour Mono high resolution 480 TVL 1 3 SuperHAD CCD 0 7 lux at F1 2 DM ICED CMH39 B Colour Mono high resolution 480 TVL 1 3 SuperHAD CCD 0 7 lux at F1 2 Black shroud DM ICED CMH39 N Colour Mono high resolution 480 TVL 1 3 SuperHAD CCD 0 7 lux at F1 2 NTSC DM ICED CMU39 Colour Mono ultra resolution 540 TVL 1 3 SuperHAD CCD 0 7 lux at F1 2 DM ICE
4. D CMU39 B Colour Mono ultra resolution 540 TVL 1 3 SuperHAD CCD 0 7 lux at F1 2 Black shroud DM ICED CMU39 N Colour Mono ultra resolution 540 TVL 1 3 SuperHAD CCD 0 7 lux at F1 2 NTSC DM ICED DNU39 Day Night ultra resolution 540 TVL 1 3 SuperHAD CCD 1 0 0 15 lux at F1 2 DM ICED DNU39 B Day Night ultra resolution 540 TVL 1 3 SuperHAD CCD 1 0 0 15 lux at F1 2 Blk shrd DM ICED DNU39 N Day Night ultra resolution 540 TVL 1 3 SuperHAD CCD 1 0 0 15 lux at F1 2 NTSC DM ICED DUM Dummy Dome Dedicated Micros 2007 Important Safeguards Product Safety WARNING Installation and servicing is only to be carried out by suitably qualified and experienced personnel Do not remove covers as there is a risk of injury or death by electric shock Only power low voltage dome cameras from a class 2 isolated power supply This camera range is designed for use in general purpose CCTV applications and has no other purpose Only operate your camera between the temperatures of 10 C and 50 C Do not operate your camera outside its specified power supply range Electromagnetic Compatability EMC CAUTION This product is intended solely for use in general CCTV applications The product must be installed and maintained in accordance with good installation practice to enable the product to function as intended and to prevent problems Refer to your agent for installation guidance Declaration of Conformity
5. The manufacturer declares that the equipment supplied with this manual is compliant with the essential protection requirements of the EMC directive 89 336 and the Low Voltage Directive LVD 73 23 EEC Conforming to the requirements of standards EN55022 for emissions EN61000 4 parts 2 3 4 5 6 and 11 for immunity and EN60950 for Electrical Equipment safety FCC CLASS B REGULATORY NOTICE This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiv
6. ation Hi sets the camera to switch between day and night mode at higher light level Lo sets the switching point at a lower light level The default setting is Lo When in Night mode the IR cut filter is removed allowing infra red illumination to be used Colour Burst DN versions only The Colour Burst CB switch allows the colour burst component of the signal to be turned on or off When a day night camera switches to night mono mode the colour burst can be switched OFF for a true monochrome signal Note that some multiplexers recorders detect video loss if the colour burst signal disappears If problems are encountered with the multiplexer recorder when the camera switches to mono try setting CB to ON Default is CB OFF Lens Level Adjust the lens iris level according to the lighting conditions 1 Turn the Automatic Gain Control switch OFF 2 Adjust the Lens Level potentiometer so that a 1 V peak to peak signal is achieved Use care so as not to damage the potentiometer 3 Turn the Automatic Gain Control switch ON Local Video Out Provision is made for the connection of a local video monitor to assist in setting up the camera Use the optional service connector DM ICED SERV not supplied Dedicated Micros 02007 Final Assy When all the connections and adjustments have been made re attach the camera liner and dome cover RENE Car DM ICED DUM only A self adhesive blanking label is supplied to cover the openin
7. be removed Gently squeeze together opposite sides of the shroud as shown and lift it away from the camera body 2 Using the template supplied at the rear of this manual mark and cut a 4 100 mm diameter hole A suitably sized hole saw can also be used To prepare for installation use a suitable screwdriver to loosen the three fixing clamps sufficiently to accommodate the thickness of the tile or ceiling 3 Connect the video to either the BNC at the end of the flying lead or directly to the BNC Use only one of the BNC connectors to connect video Connect the power to the power terminals These cameras are designed to operate from a 12V DC or 24V AC power supply Connections and polarity are indicated next to the terminals The power supply must be a UL Listed Class 2 isolated type 4 Insert the camera into the hole Using a suitable screwdriver tighten the three fixing clamps as shown Do not overtighten the clamps Camera Adjustment Camera Position The camera assembly is adjustable in all three axes Adjust the camera until it is pointing in the desired direction FOV amp Focus Use the levers on the varifocal lens to adjust the camera s field of view and focus Dedicated Micros 2007 Controls and Switches Function Backlight Compensation Automatic Gain Control Electronic Iris Line Lock Switch Function 1 Day Night D 2 Colour Burst Default setting
8. g in the liner Dedicated Micros 2007 Appendix Dimensions 105 mm 120 mm lt lt 4 13 4 72 R E z _ Elx ua o9 9 e d E 60 mm 45 mm 236 in 1777 ls 110 mm 120 mm 4 33 1 4 72 Els Elg _ gio A Dedicated Micros 2007 Quickstart Dedicated Micros 02007 Templates 25mm 1 4 5mm 64 32 5mm 1 2 4mm 3 16 43mm 1 6 NOT TO SCALE Dedicated Micros 02007 Index AGC Automatic Gain Conill iii Pa Saa tenente terere tenete tenete 8 Appendix Backlight Compensation Camera Adjustment Camera Care Camera Position Colour Burst Contents Controls and Switches Day Night Declaration of Conformity Dimensions Dip Switches DM ICED DUM only Electromagnetic Compatability EMC Electronic ig 1 tente FCC CLASS B REGULATORY NOTICE Final Assy FOV amp Focus Eu at 11 8 7 5 7 9 2 8 9 4 1 8 0 4 8 4 9 7 4 15 6 3 9 8 9 4 2 7 6 Installation Introduction Lens Level Line Lock Local Video Out Product Safety Quickstart Recess Mount Installation Surface Mount Installation Dedicated Micros 2007
9. ing antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a different circuit different to the receiver Consult the dealer or an experienced radio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Dedicated Micros 02007 Camera Care In order to avoid damaging your camera note the following points CAUTION Remove all packaging inserts and the protective film from the dome cover before using the camera Do not touch the image surface of the sensor If the sensor is accidentally touched only clean it using isopropanol Do not expose the camera sensor to very bright light over a long period of time as this may cause damage to the CCD sensor The camera and lens set up must be correct to avoid possible damage due to long term exposure to bright light A lens with an automatic iris is recommended under these conditions Dedicated Micros 2007 Installation 1 2 Warning Parts Supplied The ICE dome camera can be mounted in two ways ceiling mount for installation into a tile ceiling surface mount for installation directly to a hard surface or mounting structure 2 x Plastic anchors 2 x 80 mm 3 screws Parts Not Supplied Optional video service lead part number DM ICED SERV Surface Mount Ceiling Mount Surface Mount Installa
10. tion Refer to the Quickstart section for more information To remove the dome cover rotate it counter clockwise and gently pull it away from the camera body The inner liner can now be removed Using the template supplied at the rear of this manual mark and drill the holes required for fixing Using the two 80 mm mounting screws attach the dome camera to the surface as shown Do not over tighten the fixing screws The screws can be used on their own if the surface is of a suitable material e g wood but plastic anchors must be used where the surface is of brick or masonry construction Run the power and video cables to the camera Cables may be fed through the ceiling or through the cutout in the side of the camera shroud Remove the cutout with a sharp knife and use a round file to smooth the edges if necessary Connect the video to either the BNC at the end of the flying lead or directly to the BNC Use only one of the BNC connectors to connect video Connect the power to the power terminals These cameras are designed to operate from a 12V DC or 24V AC power supply Connections and polarity are indicated next to the terminals The power supply must be a UL Listed Class 2 isolated type This camera is a Class 2 device and therefore does not have an earth connection in the power cord Dedicated Micros 02007 Recess Mount Installation Refer to the Quickstart section for more information 1 To recess mount the camera the shroud must
Download Pdf Manuals
Related Search
Related Contents
D-Link DGS-1210-24P network switch BitDefender Security for SharePoint 3.5 Desktop-styled Attendance Machine User Manual DGP8761シリーズ 水冷チャックテーブル取付け方向に関する訂正のご連絡 Seite auswählen und drucken Copyright © All rights reserved.
Failed to retrieve file