Home

RGB DMX Deck Skirt 2.1M x 1M Starcloth (order code

image

Contents

1. WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property LEDJ RGB DMX Deck Skirt Technical specifications Operating modes 1 Stand Alone with Sound Activation 2 DMX operation For Sound Activation With the power turned off set dip switch 10 to ON and all others to OFF Turn on the power and the sensitivity control can now be set to the desired level For DMX operation With the power turned off set dip switch 10 to OFF then using dip switches 1 9 set the desired DMX address and then turn on the power You can now control the RGB deck skirt using the table below DMX table DMX Number Function 10 19 Pattern number 1 Pattern number 2 Pattern number 3 Pattern number 4 Pattern number 5 Pattern number 6 Pattern number 7 Pattern number 8 Pattern number 9 Channel 1 Pattern number 10 Pattern number 11 Pattern number 12 Pattern number 13 Pattern number 14 Pattern number 15 Pattern number 16 Pattern number 17 Pattern number 18 Pattern number 19 Pattern number 20 Pattern number 21 Pattern number 22 230 239 Pattern numbe
2. 282 314 378 442 474 LEDJ RGB DMX Deck Skirt Maintenance Maintenance The RGB DMX Deck Skirt requires almost no maintenance However you should keep the unit clean otherwise the fixture s light output will be significantly reduced Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid The cloth will require monthly cleaning as smoke fluid tends to build up residues reducing the light output very quickly Do not use alcohol or solvents Keep connections clean Disconnect the power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry before re connecting the power supply The following points have to be considered during the inspection 1 All screws used for installing the device have to be tightly connected and must not be corroded 2 There should not be any deformations on housing fixing and installation points 3 The electric power supply cables must not show any damages or material fatigue Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to fail If the fuse fails the product will not function whatsoever If this happens follow the directions below 1 Unplug the unit from electric power supply 2 Insert a flat headed screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push Turn and Push The fuse will come out 3 Remove the
3. 352 s i6 a5 a0 ESEJEJESE JEJE TE JEAE JEEJE JOE E 66 98 130 162 194 226 258 290 322 354 386 418 450 482 a rae a 2 3s os vu EEE oe s 4v ar sS ior 135 EE 255 os EEE 3s 70 uz EE 286 26 98 300 zz ssa 45 el ae 3E JE AE JEIEE DEAE EJESEE a0 72 104 136 68 200 232 254 z36 28 380 302 28 56 6 i r s us vor v rs a ros s ns pes ere Li 42 7a vos Faw EE JEJEJEJE Er as 1s sor 38 as 255 zer os ss ses 5 zr e sv Liz ps 76 vos ab 172 294 256 258 f 300 3g 364 396 408 480 Eis as rr sos ver zs 05 257 269 sov 3 ses or os as ss Las 76 vi az vrs 206 ae 276 ane EE E Fus 47 ra 41 43 175 207 239 2rt 303 335 aer 399 431 465 495 112 176 208 240 272 336 432 KJ LiT a we i3 sas vrT 08 Bat 275 305 sr 368 40i 435 e5 497 82 114 178 210 242 274 338 370 402 434 498 EST 85 He var vr z11 43 z75 BOT ss STF us 435 LAE 20 52 116 212 244 276 372 436 468 500 Ear sa ss 7 as ves zi3 aus zrr 309 sav 378 o5 EEE 22 s a5 118 150 182 214 226 278 to sez 374 406 aas ro 502 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503 24 88 120 152 216 248 280 312 376 408 472 25 57 wo Wat 53 es nir aes EEE JEE 122 218 250
4. and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation The RGB Deck Skirt can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split LEDJ RGB DMX Deck Skirt DMX Set Up Notice Be sure to follow figures 2 8 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic be
5. used fuse If brown or unclear it has failed 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product specification label for details Technical Specifications Voltage 240V AC 50Hz Wattage 5W LED s R 32 G 32 B 32 Total 96 Dimensions 2 1m x 1m Weight 3kgs
6. WWW PROLIGHT CGO UK RGB DMX Deck Skirt 2 1M x 1M Starcloth order code STAR25 USER MANUAL LEDJ RGB DMX Deck Skirt Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty LEDJ RGB DMX Deck Skirt Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipmen
7. h has an associated value Adding the value of each switch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address until zero is achieved EXAMPLE STARTING ADDRESS Address 10 zc Pin NO 4 8 T Mo es pm Pin NO 2 2 Total 10 NBOprWA gt NO 5 Address 24 on Pin NO 5 16 1 Pin NO 4 8 TOM o Total 24 Poe ee 5 233 128 105 Turn on dip No 8 DMX address using 105 64 41 Turn on dip No 7 DIP SWITCH DMX VALUE simple maths 41 32 9 Turn on dip No 6 9 8 1 Turn on dip No 4 1 1 0 Turn on dip No 1 You will most likely use the first available number which maybe Number 1 This number was selected for 1 2 3 4 5 16 6 7 8 9 example purposes eo LEDJ RGB DMX Deck Skirt DMX setup DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together
8. haviour common DMX 512 out 3 pin XLR DMX 512 in 3 pin XLR KESSE ESE ee eee XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground o Pin 2 Negative 3Hot 3Hot Pin 3 Postive FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 3 Pin XLR to 5 PIN XLR Conversion Conductor 3 Pin XLR out 5 Pin XLR in Ground shield Pin 1 Pin 1 Negative Pin 2 Pin 2 Positive Pin 3 Pin 3 LEDJ RGB DMX Deck Skirt Dip Switch Reference Chart DMX Dip Switch Quick Reference Chart Dip Switch Position AO PPPPP KK KA KKK KK KK KA z kala USB USUS i CR LB C CUR OR UR C mpeg aa oo CR RAN EUM eee 325 166 82 24 256 286 320
9. r 23 LEDJ RGB DMX Deck Skirt DMX Number Channel 1 lei continued 250 255 Channel 2 Side view Technical specifications Function Pattern number 24 Auto run through all programmes Animates the pattern selected on channel 1 The higher the number the faster the speed Back view Identfication 1 Power switch 2 Power supply 3 Fuse 4 Volume control 5 Microphone 6 Starcloth power output 7 Starcloth signal output 8 Dip switches 9 DMX in 10 DMX out LEDJ RGB DMX Deck Skirt DMX control mode DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 Set the start address using the group of dip switches located usually on the back of the fixture Each dipswitc
10. t Do not open the equipment and do not modify the equipment Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature f your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS