Ness R8 - Installation

image

Contents

1. EXAMPLE TO TEST THE SIGNAL STRENGTH OF A RADIO KEY 1 Press PO8E OE Radio icon is flashing waiting for radio data 2 Press and hold the Panic button for 2 seconds on the Radio Key being tested 3 The display will alternate flashing signal strength value and radio key slot number E g The signal strength will be flashed on the display and the panel will beep signal strength value Then the radio icon and detector key number will be on steady EJ Ness R8 Installation and Programming Manual PROGRAMMING MOE PROGRAM RADIO DEVICES PROGRAM MODE LEVEL The R8 has eight radio zones which can accept Ness radio devices Installer Remote by PC such as radio PIRs radio reed switches radio smoke detectors FACTORY DEFAULT Each of the eight radio zones will accept one radio device No radio devices Radio devices are programmed with the easy to use radio learn programmed mode NOTES PROGRAMMING SEQUENCE 1 Press PO9E RELATED OPTIONS OPTIONS The RADIO icon will turn on and zone numbers 1 8 will show which zones have radio devices programmed 2 Press zone number E The selected zone number is flashing The zone is in learn mode Along beep indicates that the radio device may already be programmed on another zone 3 Connect the battery in the radio device Three beeps indicates device has been successfully programmed EXAMPLE 1 To program radio zone 1 with a Ness Radio PIR 1 Press PO9E 1E Zon
2. ENTRY DELAY ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 ON Zone 1 is Delayed NOTES When a zone is selected as Entry Delay it is automatically deselected from Instant or Handover Entry Delay zones operate only in the Armed state When Armed at the expiry of exit time these zones will activate the Entry Delay Timer P26E when they are triggered If the panel is not disarmed before the expiry of the Entry Delay Timer the alarm outputs will be activated PROGRAMMING SEQUENCE 1 Press P42bE 2 Press 1 8 E to enable each zone for this option To deselect a zone from this option program it to be Instant or Handover Zone light s on indicates which option is enabled HANDOVER ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 2 ON Zone 2 is Handover NOTES When a zone is selected as Handover it is automatically deselected from Entry Delay or Instant Handover zones are delayed only if entry is made through an Entry Delay zone first If a Handover zone is triggered first the zone behaves as an instant zone Normally the point of entry zone should be Delay zone with any other zones in the entry path programmed as Handover zones PROGRAMMING SEQUENCE 1 Press P42bE 2 Press 1 8 E to enable each zone for this option To deselect a zone from this option program it to be Delayed or Instant e Zone light s on indica
3. Press P74E Alarms 2 Press 1 8 E to toggle each zone on or off RELATED OPTIONS Zone light s on indicates which option s are enabled P76E Report Zone Restorals P75E REPORT MISCELLANEOUS ALARMS See page 38 P76E REPORT ZONE RESTORALS PROGRAM MODE LEVEL This option selects the zones which will report Restorals by dialler Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE 1 8 ON All zones report 1 Press P76E Restorals 2 Press 1 8 E to toggle each zone on or off RELATED OPTIONS Zone light s on indicates which option s are enabled P74E Report Zone Alarms P82E 1E 4E Sending Restorals Ness R8 Installation and Programming Manual ES PROGRAMMING REPORT MISCELLANEOUS ALARMS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E ON 3E ON 4E ON 5E ON 6E not used 7E ON 8E OFF RELATED OPTIONS P77E Report Miscellaneous Restorals This option selects the non zone events which will report alarms by dialler P75E 1E REPORT DURESS ALARM OFF Duress Alarm reporting is disabled ON Duress Alarm reporting is enabled Default OFF P75E 2E REPORT MEDICAL ALARM OFF Medical Alarm reporting is disabled ON Medical Alarm reporting is enabled Default ON P75E 3E REPORT PANIC ALARM This option applies to keypad panic and radio key panic OFF Panic Alarms reporting is disabled ON Panic Alarms r
4. as follows SSSS 18 Q XYZ GG CCC E SSSS18 Client Account Number Contact ID identifier Q Event qualifier 1 New Event 3 Restore XYZ Event code GG Group Number always 00 CCC Qualifier 0 9 User ID uu Zone ID zz or Unique Code 030 099 E Checksum CONTACT ID CODE REPORTED IN REPORT NAME Q XYZ ccc VOICE FORMAT RESTORAL REPORTS Zone Alarm q 130 Ozz Yes Zone 24 Hour Alarm q 133 Ozz Yes Restores are always sent for the following Keypad Panic q 120 032 Yes alarms when the device Keypad Radio Key Duress q 121 tuu Yes alarm condition is Keypad Medical q 100 033 Yes pnysicallyiremovedi Keypad Fire q 110 034 Yes n E ae nas Radio Key Panic q 120 1uu Yes 383 Tamper Detector Radio Key Medical q 101 1uu Yes 381 Radio device Radio Detector Supervision q 381 4zz supervision poll fail Radio Panic Button Supervision q 381 1uu Radio Jamming or Substitution q 355 060 Restores are always sent for the following Panel Siren Tamper q 137 040 Yes alarms on disarming Keypad Tamper q 137 042 Yes when a valid code is Radio Sensor Tamper q 383 3zz Yes entered if Restores are enabled Mains Fail q 301 050 101 Radio Key Medical Panel Battery Low q 302 052 ERU Radio Detector Battery Low q 384 3z 120 Panic alarm Open Disarm 1 401 Ouu 121 Duress alarm Close Arm 3 401 Ouu 130 Burglary alarm Shorcut Arm ARM E 3 401 025 133 24 hour alarm Cancel Disarm 1 406 Ouu 355 Radio jamming Zone Manual Exclude q 573 Ozz alarm Zo
5. Day Zone alarms EJ Ness R8 Installation and Programming Manual P60E 1E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON 2E not used 3E not used 4E ON 5E not used 6E ON 7E OFF 8E OFF NOTES PROGRAMMING MISCELLANEOUS OPTIONS P60E 1E ENTRY BEEPS ON Enables keypad beeps during Entry Delay OFF No keypad beeps during Entry Delay Default ON P60E 2E Not used P60E 3E Not used P60E 4E TAMPER SIREN LOCKOUT OFF Tamper alarms can trigger multiple alarms ON Tamper Alarm lockout The siren output sounds once and then locks out if multiple Tamper Alarms occur The siren outputs become active again once the panel has been reset by a User Code Default ON P60E 5E Not used P60E 6E AUTO EXCLUDE ZONES OFF No AutoExclude an unsealed zone will alarm at the end of exit delay ON AutoExclude enabled If the panel is armed with an unsealed zone that zone will be Autoexcluded and the panel will give a 2 second Siren burst at the end of Exit Time to indicate that the panel is armed with a zone s Auto Excluded The 2 sec Siren burst can be disabled by option P62E 7E Default ON P60E 7E KEYPAD BACKLIGHT BLANKING OFF Keypad Backlighting is always on ON Keypad Backlighting blanking enabled The backlighting on the keypad can be programmed to blank after 4 minutes of no keypad use Any action that causes a beep will restore the back lig
6. E 123 is the factory default This is User Program 000000 six zeros is the factory default This is Installer Program Master Code Mode The PROGRAM Installer Code Mode The PROGRAM icon is on steady icon is flashing To program the Master Code Example to program the Master Code to be 1234 Press WVD VOOWO VDOVE P11E is the option for Enter the new Master Code Enter the new Master Code again the Master Code followed by E followed by E To program the dialler Client Account Number Example Client Code is 9876 Press PAE OOOO P72E is the option for Enter the new Client Account the Client Code Number followed by E To program the central station telephone number Example telephone number is 1234 7890 Press QP VYOO VDOOOWOOOO P70E is the option for Enter the new telephone number followed by E Telephone Number 1 O To exit Installer Program Mode Press P followed by E The PROGRAM icon will turn off THE PANEL IS NOW PROGRAMMED AS FOLLOWS Master Code 1234 Dialler Client Account Number 9876 Central Station Telephone number 1 1234 7890 Zone 1 Delay Zone 2 Handover Zones 3 8 Instant Entry Delay Time 20 seconds Exit Delay Time 60 seconds Siren Reset Time 5 minutes The client code and telephone numbers are supplied by the central station E Ness R8 Installation and Programming Manual QUICK START RADIO PROGRAMMING As a radio system the Ness R8 can be installed with a mini
7. OFF The dialler is enabled The dialler will still remain disabled if no telephone numbers are programmed ON The dialler is disabled PROGRAMMING SEQUENCE 1 Press P86E 2 Press 1E to turn the option on or off Zone light s on indicates the option is enabled P87E 2E CHECK FOR DIAL TONE PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Check for dial tone NOTES The dialler normally dials only if a dial tone is detected or it can be forced to dial without a dial tone Allows use on PABXs with non standard dial tones OFF Does not check for dial tone ON Check for dial tone hang up on busy tone PROGRAMMING SEQUENCE 1 Press P87E 2 Press 2E to turn the option on or off Zone light s on indicates the option is enabled Ness R8 Installation and Programming Manual EN PROGRAMMING P88E 1E ENABLE OPEN CLOSE REPORTS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Open Close reports disabled NOTES Enables or disables sending of Open Close reports OFF Open Close reports disabled ON Open Close reports enabled PROGRAMMING SEQUENCE 1 Press P88E 2 Press 1E to turn the option on or off Zone light s on indicates the option is enabled P88E 5E ALARM CANCEL REPORT PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Cancel Report enabled NOTES This option is used to indicate
8. OFF No 24hr zones NOTES The Tamper input is always a 24hr zone 24hr Zones operate at all times regardless of the mode of panel operation i e Armed Disarmed or Monitor When alarmed these zones will activate assigned outputs immediately To reset a 24hr zone alarm a valid user code must be entered Selecting a zone as 24hr will override any other zone type setting such as Instant Delayed or Handover PROGRAMMING SEQUENCE 1 Press P52E 2 Press 1 8 E to enable each zone for this option To deselect a zone from this option program it to be Delayed Instant or Handover Zone light s on indicates which option s are enabled Ness R8 Installation and Programming Manual 29 PROGRAMMING ME ESTE PROGRAM MODE LEVEL Day Zones operate when the panel is fully disarmed i e when fully Installer Remote by PC disarmed and Monitor mode is off When alarmed Day Zones will FACTORY DEFAULT activate the assigned outputs instantly 1 8 OFF No Day zones This option selects which zones will be Day Zones NOTES Typical uses PROGRAMMING SEQUENCE e Instant alert when a delivery 1 Press P53E door is opened 2 Press 1 8 E to enable each zone for this option To deselect a zone from this option program it to be Delayed Instant or Handover e Zone light s on indicates which option s are enabled Doorway alert for a shop RELATED OPTIONS P64E 2E Brief Day alarm Programs the behaviour of
9. alarm 3E Medical The Panic Button will trigger the Medical alarm 4E Ignore Panic Disables Panic Button on radio keys 5E Doorbell The Panic Button will sound the R8 doorbell feature Each user code slot is defaulted for Extra Option 1E trigger Panic The Extra option for a user code slot can be programmed after a radio key has been programmed to that slot PROGRAMMING SEQUENCE FOR EXTRA OPTIONS 1 Press P user number option 12 25 E If a Radio Key is programmed to the user slot the RADIO icon will be on Icons 1 5 show which Extra Option is currently selected 2 Press 1 5 E This selects a new Extra Option EXAMPLE A Radio Key is programmed to User Code slot 2 To change the Extra Option to Ignore Panic press P12E 4E USER CODE OPTIONS TABLE RADIO CODES KEYPAD CODES USER CODE SLOT DESCRIPTION OPTION NOs OPTION NOs DEFAULT User Code 1 Master Code Always a Keypad Code User Code 2 P10E 2E User Code 3 3E User Code 4 4E User Code 5 5E User Code 6 6E User Code 7 7E User Code 8 8E User Code 9 9E User Code 10 10E User Code 11 User Code 12 User Code 13 User Code 14 User Code 15 Ness R8 Installation and Programming Manual EJ PROGRAMMING PROGRAM KEYPAD CODES PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT User Code 1 123 Installer Code 000000 All other codes
10. number 2 will be flashing Numbers 2 15 show the status of the user slots ON Radio Keys programmed OFF blank flashing learn mode O Press and hold the PANIC button for 8 seconds on the Radio Key to be programmed Beep beep 3 beeps will be heard if the RADIO KEY was successfully learned Number 2 will then be on steady A long beep means the Radio Key is already programmed to another user slot See page 24 To exit Installer Program Mode Press P followed by E The PROGRAM icon will turn off Ness R8 Installation and Programming Manual 17 This page is intentionally blank ES Ness R8 Installation and Programming Manual PROGRAMMING PROGRAM MODE LEVELS USER PROGRAM Power up wi bis box lid open Usually on first time installation MODE User Program Mode allows the INSTALLER PROGRAM Mode PE Owner i PROGRAM LIGHT IS FLASHING program All User Codes Entry and Exit INSTALLER CODE times Q l JO Note The panel Factory default Installer Code 000000 will automatically t drop out of User USER PROGRAM Mode Program Mode to Ls i jp E n n Operating Mode SAN TERT if no keypad buttons are P MASTER CODE E pressed for 4 Factory default Master Code 123 minutes NORMAL OPERATING Mode PROGRAM LIGHT IS OFF INSTALLER PROGRAM MODE Installer Program HOW TO ENTER PROGRAM MODE Mode allows access to ALL program FROM POWER UP options 1 Power up with the internal
11. on indicates which option s is enabled REPORT MULTIPLE ZONE ALARMS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 8 ON All zones report Multiple Zone Alarms RELATED OPTIONS P74E Report Zone Alarms Zones selected to Report Multiple Zone Alarms will report each time the zone alarms The number of reports is a maximum of 15 Zones not selected will report only once until reset by an opening or a valid code PROGRAMMING SEQUENCE 1 Press P78E 2 Press 1 8 E to toggle each zone on or off Zone light s on indicates which option s is enabled RESTORAL REPORTING OPTIONS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 4E ON Send Restoral on Disarm always RELATED OPTIONS P74E Report Zone Alarms This option selects when the dialler sends Zone Restoral Reports Only one of the following options may be selected Restoral reporting options also apply to 24hr zones P82E 1E Send Restoral immediately when resealed P82E 2E Send Restoral after siren time amp resealed P82E 3E Send Restoral on Disarm amp resealed P82E 4E Send Restoral on Disarm always PROGRAMMING SEQUENCE 1 Press P82E 2 Press 1 4 E to toggle each option on or off Zone light s on indicates which option is enabled Ness R8 Installation and Programming Manual EJ PROGRAMMING TEST CALL INTERVAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEF
12. time before the first test call E g If you are programming the panel at 5pm and you want test calls to be sent at 1am Enter P84E 8E 5pm 8hrs 1am P83E and P84E timers start on exit from Installer program Mode 40 Ness R8 Installation and Programming Manual PROGRAMMING DIALLING METHOD PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Automatic Pulse or DTMF NOTES Turning ON one of the options will turn OFF any other The dial format is determined by the detected Dial Tone By default if no dial tone is detected after looping the line then the dialler will attempt to dial regardless alternating between PULSE Decadic first and then DTMF dialling P85E 1E Automatic PULSE or DTMF determined by the detected dial tone P85E 2E Pulse Dialling always P85E 3E DTMF Dialling always PROGRAMMING SEQUENCE 1 Press P85E 2 Press 1 3 E to turn an option on Zone light s on indicates which option is enabled P86E 1E DISABLE DIALLER PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Dialler is enabled NOTES The dialler can also be disabled by deleting all telephone numbers This option disables the dialler even if telephone numbers and other dialler options are programmed Up download or remote telephone access remain enabled This option is useful for temporary disabling of the dialler without affecting other dialler options
13. to the BATTERY socket on the main board 8 Turn on the plug pack Note 1 When power is applied the R8 will enter Disarmed mode unless it was in Armed or Monitor mode when previously running in which case it will resume in the previous mode UNLESS the box tamper or external tamper inputs are unsealed See note 2 Note 2 To enter Installer Program Mode on initial power up apply power with the internal tamper open lid open or the external tamper open Note 3 The BATTERY icon will flash ifthe initial battery voltage is low and will turn off when the battery has reached full charge EN Ness R8 Installation and Programming Manual INSTALLATION CONDUIT TERMINAL BOARD CABLE TIE CABLE TIE EXTERNAL ANTENNA Om E i e FRONT o HOUSING o rear 9 CABLE TIE so o o BACK HOUSING Q p O E LI CL LE T b 6 CABLE ENTRY VIA CONDUIT MOUNTING SCREW Era o CONNECTING LEAD EXTERNAL ANTENNA The external antenna supplied can be fitted if required CABLE TIE CABLE TIE The sensitivity of the R8 radio receiver with or without the BACK HOUSING external antenna is subject to E 9 RF conditions specific to the site Tests have shown that most sites will perform well using the standard
14. unsealed Zone alarm Y Not ready to arm unsealed READY zones or system faults Ready to Arm f ARMED Disarmed Armed Ger Disarmed Monitor Mode lo Normal Mains Power is off oral The panel s backup BATTERY battery is low ll A Normal Memory Mode selected New alarms in memor MEMORY y y D EXCLUDE Normal Zones are excluded IT tamper Normal Tamper alarm 9 N Receivi dio si Indicates that a Radio Key or A RADIO orma ecelving radio Signa other radio device has a low battery Phone line fault or LINE Normal Dialler is on line failure to communicate PROGRAM Normal User Program Mode Installer Program Mode Numeric display 1 15 will show which device is sending the Low Battery signal KEYPAD BEEPER NOTE If the onboard siren is disabled P60E 8E on keypad beeps are also disabled during an alarm condition Keypad beeps will be reactivated on the next disarm USER TESTS Test functions can be invoked by pressing and holding the specified keypad button as follows The Panel must be in Disarmed mode BUTTON TEST PERFORMED 9 Dialler Listen in Press and hold keypad button 9 for 3 seconds to enable the Dialler Listen in function All dialler tones are output through the onboard siren This allows the installer to hear dial tone dialling tones central station handshake and kiss off tones This test automatically turns off after 2 minutes Display Test Press and hold keypad button E for 1 5 seco
15. AULT 168 168hrs 7 days NOTES To disable Test Reports program the test call interval to 0 zero hours RELATED OPTIONS P84E Time Before Next Test Call This option sets the time between Test Calls to the Central Station Programmable from 0 255 hours Enter a value between O and 255 A value of 0 zero disables test calls PROGRAMMING SEQUENCE 1 Press P83E The digits of the existing value will be displayed 2 Press new test call interval E The digits of the new value will be displayed TIME BEFORE NEXT TEST CALL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0 Ohrs Immediate on exit from installer program mode NOTES The Time Before Next Test Call is constantly updated When viewed the current value will be displayed not the initially entered value RELATED OPTIONS P83E Test Call Interval DAYS HOURS TABLE DAYS OJIN A ov e o This option sets the time before the next test call and is used to set the preferred time for Test Calls Programmable from 0 255 hours Enter a value between O and 255 A value of O zero triggers the next test call immediately on exit from Installer program Mode PROGRAMMING SEQUENCE 1 Press P84E The digits of the existing value will be displayed 2 Press new time before next test call E The digits of the current value will be displayed PROGRAMMING EXAMPLE To set the
16. Control Panel The control panel backup battery is periodically load tested A low battery condition is cleared when the battery passes load test Battery is tested once every 1 hour and on every disarm Flash the LCD BATTERY icon RADIO SUPERVISION FAIL Radio PIR or Fixed Radio Panic Button A radio supervisory message or other message has not been received from a detector for the programmed supervision period Flash the LCD RADIO and zone number icons MAINS POWER FAIL Indicates AC mains power to Panel is not connected or power is off Flash the LCD MAINS icon FAIL TO COMMUNICATE Indicates the dialler was not able to successfully contact the central monitoring station Flash the LCD LINE icon All alarm types can be reported to the Central station See page 48 for a full list of Contact ID reporting codes Ness R8 Installation and Programming Manual 15 QUICK START PANEL PROGRAMMING The Ness R8 is supplied pre programmed with factory default values that should suit most installations The steps below will show you how to program the Master Code User Code 1 and the Client Code and telephone number for central station monitoring O To enter Installer Program Mode To enter Installer Program Mode on initial power up apply power with the internal tamper open lid open or the external tamper open Or if you have powered up with all tampers sealed see below then press fis res ODODO P0000000
17. GRAMMING SEQUENCE 1 Press P28E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program the exit delay time to be 50 seconds P28E 50E SIREN RESET TIME PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5 5 minutes NOTES Programmable range is 1 10 minutes To view the programmed value without making changes press P29E The Siren Reset Time sets the alarm duration of the Siren and Reset outputs PROGRAMMING SEQUENCE 1 Press P29E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program the siren reset time to be 4 minutes P29E 4E Ness R8 Installation and Programming Manual ES PROGRAMMING INSTANT ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 3 8 ON Zones 3 8 are instant NOTES When a zone is selected as Instant it is automatically deselected from Entry Delay or Handover Instant Zones operate only in the Armed state Once armed at the expiry of exit time Instant Zones will activate assigned outputs immediately when triggered PROGRAMMING SEQUENCE 1 Press P40E 2 Press 1 8 E e This enables the zone for this option To deselect a zone from this option program it to be Entry Delay or Handover Zone light on indicates the option is enabled
18. LINE Dialler Call Fail LINE Zone Alarm 1 8 Tamper Panel Siren TAMPER Tamper 4 failed attempts TAMPER PROGRAM Radio Jamming RADIO Radio Substitution RADIO Pendant Low Battery RADIO BATTERY 2 15 Pendant Panic Medical RADIO EXCLUDE Detector Tamper RADIO TAMPER 1 8 Detector Low Battery RADIO BATTERY 1 8 Detector Supervision Fail RADIO 1 N Pendant Supervision Fail RADIO MONITOR 1 8 12 Ness R8 Installation and Programming Manual OPERATION SUMMARY e OPERATION KEYPAD 9 RADIO KEY ARM User Code E The panel must be in Arming Shortcut a Disarmed state first d E must be ON P62E 5E DISARM To Disarm and or reset User Code E alarms MONITOR MODE User Code E The panel must be in Monitor Shortcut Press ON button twice a Disarmed state first E must be ON P62E 3E within 4 seconds 9 N Extra Options for the FRE PANG MEDICAL Panic button must be set EN ED for PANIC P12E P25E 1E Both keys together This is the factory default Keypad Panic must be enabled P62E 6E KEYPAD DURESS 9 User Code E Extra Options for the To Disarm and report a Duress Alarm add the Fani button must be set en A E for DURESS digit 9 before the User Code when Disarming P12E P25E 2E P75E 1E must be enabled to report the alarm EXCLUDING ZONES User Code E Zones can be Excluded when the panel is disarmed
19. NEGF 1 58 MADE AUSTRALIA UM Y INSTALLATION amp PROGRAMMING MANUAL Ness R8 Radio Control Panel Installer s Manual A 15 00 INC GST Revision 2 Australia s largest designer and manufacturer of high quality security products MADE uU N55 NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE Quality Endorsed Company IS09001 LIC No QEC2074 Ness Security Products Pty Ltd NSW Head Office only WWW NESS COM AU HEAD OFFICE Ness Security Products Pty Ltd ABN 28 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au SYDNEY 02 8825 9222 MELBOURNE 03 9878 1022 BRISBANE 07 3343 7744 PERTH 08 9328 2511 ADELAIDE Aquavia Controls 08 8277 7255 NEW ZEALAND NFS NZ 64 9 573 0401 NESS R8 INSTALLER MANUAL Revision 2 October 2002 Document Part Number 890 273 For product 100 690 Ness R8 Control Panel O 2002 Ness Security Products Pty Ltd ABN 28 069 984 372 R8 installer rev2 pmo091002 Specifications may change without notice CONTENTS IntrOQUCtiOr t dne i eee E ce Decet d es 4 Compatibility deett date a 5 INSTALLATION os cheat ren eed aa AA ee 6 Power Up procedure civic 6 Connection Diagtam 3 wits vinden erre rre wi ede E reve E ee c 8 Inputs OUtpUls x tinent ot p ar m n oat rene 9 H8 Keypad en eee a 10 Aud
20. SUMMARY Pave 3 0f4 RADIO PANEL OPTION No DESCRIPTION DEFAULT PAGE P75E 1E Report Duress Alarm Report 2E Report Medical Alarm misc ALARMS 3E Report Panic Alarm 4E Report Fire Alarm 5E Report Tamper Alarm 6E not used 7E Report Keypad Tamper Alarm 8E Report Exit From Installer Mode see previous page Report Zone Restorals Report Misc Restorals See P75E for full list All ON Report Multiple Zone Alarms 1 8 All OFF P82E 1E Send Restoral Immediately when Resealed RESTORAL 2g Send Restoral After Siren Time amp Resealed REPORTING OPTIONS 3E Send Restoral on Disarm amp Resealed 4E Send Restoral on Disarm always Test Call Interval 168 hrs Time Before Next Test Call 0 hrs P85E 1E Auto Pulse or DTMF depending on dial tone vero 2 E Pulse Dialling always DTMF Dialling always P86E 1E Disable Dialler P87E Check For Dial Tone P88E 1E Open Close Reports 5E Alarm Cancel Report Report Supervision Alarms P89E Telephone Line Monitor Ness R8 Installation and Programming Manual INEZ R8 NESS R8 OPTIONS SUMMARY Pave 4 of4 OPTION No DESCRIPTION DEFAULT PAGE P90E 1E Remote Access UPLOAD 2E not used DOWNLOAD OPTIONS 3E Remote Arming 4E Remote Disarming Required Rings to answer incoming calls P96E Clear Event Memory P97E 1E Factory Default Panel Optio
21. There is no dialler report no external piezo and no external siren Default OFF P64E 2E BRIEF DAY ALARM This option programs the behaviour of Day Zone alarms OFF NORMAL DAY ALARMS Siren amp Reset output will be on while a Day Zone is unsealed ON BRIEF DAY ALARM Outputs are on for 2 seconds internal piezo at half volume strobe There is no dialler report no external piezo and no external siren Default ON P64E 3E Not used P64E 4E SIREN CHIRPS ARM DISARM When this option is enabled the external siren output and the onboard siren will chirp on arm disarm by radio key The strobe output always flashes on arm disarm by radio key independent of this program option 1 chirp arming 3 chirps disarming OFF Siren chirps disabled ON Siren chirps enabled Default OFF P64E 5E Not used P64E 6E KEYPAD PANIC ALARM Keypad Panic can be triggered by pressing both star keys together The dialler reports a Panic alarm if enabled by P75E 3E OFF NO KEYPAD PANIC ON KEYPAD PANIC IS ENABLED Default ON P64E 7E FIRE ALARM The Fire Alarm can be triggered by pressing the FIRE key for at least 2 seconds left hand STAR key This triggers the fire siren sound and the dialler reports a Fire alarm if enabled by P75E 4E OFF No Keypad Fire Alarm ON Keypad Fire Alarm is enabled Default OFF P64E 8E MEDICAL ALARM The Medical Alarm can be triggered by pressing t
22. Zone No E Zone No E Enter the zone numbers to be Excluded To exit Exclude mode VIEW MEMORY User Code E A Press repeatedly to display the last 20 events If the Memory Shortcut is on P62E 1E just enter E To exit Memory mode MEMORY E DOORBELL 100 056 Radio Door Bell RO Note The panel will ignore Monitor Mode arming if no monitor zones are selected at P51E Ness R8 Installation and Programming Manual I ALARM TYPE DESCRIPTIONS ALARM TYPE DESCRIPTION ALARM Detector A zone goes unsealed in a mode causing an alarm Non restoring detectors which have alarmed will send a Restore report on Disarming if Restore reporting is enabled Restoring detectors e g a reed switch programmed with Restore which have alarmed will report a Restore only when they are sealed if Restore reporting is enabled TAMPER Panel Siren Panel housing tamper switch and external siren housing tamper switch are wired to the same Tamper Input When alarmed will report a Restore only when sealed if Restore reporting is enabled TAMPER Keypad Detect entry of consecutive invalid codes in Armed mode alarm sirens on 4 failed attempt TAMPER Radio detector Radio detector housing tamper switch activation When alarmed will report a Restore only when sealed if Restore reporting is enabled PANIC Keypad Instant when both PANIC buttons pressed together or ii delayed when eith
23. a beep for 2 seconds then after a pause it will sound a lower frequency tone The R8 is now ready to receive telephone commands 4 Press the 0 button on the telephone This tells the R8 that telephone commands will follow 5 Now enter a valid User Code followed by the st button The R8 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again 6 Enter the command to arm or disarm the panel See Summary Of Telephone Commands 7 Press x to finish This tells the R8 to hang up Also hang up your telephone Ness R8 Installation and Programming Manual 49 NESS ACCESSORIES ben hse J 4 NH 9 4 100 021 100 226 100 210 100 048 Quantum Quantum Quantum Quantum 360 Plus Dual MOTION DETECTORS Ness manufactures a range of high quality and efficient motion detectors including passive infra red detectors dual technology microwave and infra red devices as well as ceiling mounted 360 detectors All Ness detectors are designed using the most modern technology and techniques that ensure superior reliability and performance QUANTUM 15m passive infra red detector with selectable pulse count suitable for domestic and commercial installations PetAware model available QUANTUM PLUS 15m passive infra red detector with selectable pulse count temperature compensation and downward looking creep zones QUANTUM DUAL 15m comb
24. ary to program a reporting format Ness Voice Dialling format is automatically selected when alarm reports are sent to the Voice Dialling telephone numbers Voice Dialling is disabled if Central Station telephone number s are programmed at P70E or P71E PROGRAMMING SEQUENCE 1 Press POOE or PO1E e The existing telephone number is displayed e It is not necessary to wait for the display sequence to end You can interrupt the display by entering the new telephone number 2 new telephone number E The new telephone number is displayed EXAMPLE To program Voice Dialling Phone No 1 to be 03 1234 1234 Press POOE 0312341234E TO CLEAR A TELEPHONE NUMBER To clear a telephone number enter the MEMORY key in place of the telephone number E g to clear Voice Dialling Phone No 2 press PO1E MEMORY E SPECIAL CHARACTERS Special characters such as Pauses star or hash characters can be included in a telephone number dialling sequence by using the keys in the table below SPECIAL CHARACTER KEYPAD ENTRY KEYPAD DISPLAYS PAUSE 1 6sec ARM Key 10 Star MONITOR Key 11 Hash EXCLUDE Key 12 EJ Ness R8 Installation and Programming Manual PROGRAMMING DOORBELL VOLUME PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 3 Volume level 3 NOTES The Doorbell sounds through the R8 onboard siren RELATED OPTIONS Doorbell Tune POGE Selects the doorbell volume Programmable range
25. at is within the protected area of the premises A linen closet 1 R8 Control panel or cupboard are good examples as these are generally located 1 Plug pack 17VAC in the centre of the Premises 300mA 1 Remove the front housing by first removing the bottom Battery 12V 0 8Ah 3 X DE uds ds locking screw screw is not fitted for shipping then Telephone lead 4 External antenna unclip the bottom of the front housing and lift upwards 1 User manual 2 Disconnect the 12 way wire loom from the main board 1 Installer manual on the front housing 1 Zone list label 3 Unclip and remove the terminal board from the back 5 AL edice housing and remove the battery The battery lead connects to the main board on the front housing It is not plugged in for shipping The terminal board and battery must be removed to reveal all four mounting 1 holes in the back housing 3 Mount the back housing to the wall using the 4 slotted e mounting holes 4 Replace the Terminal Board in the back housing and reconnect the 12 way wire loom to the main board 5 Connect the plug pack wiring to the Terminal Board making sure that mains power is not turned on at this stage Connect siren wires and external tamper inputs as required 6 Replace the battery 4 0 0 POWER UP PROCEDURE The power up procedure assumes that installation of the R8 REMOVING THE is completed and the plug pack is wired FRONT HOUSING 7 Connect the battery lead
26. blank Extra Option 1 all codes NOTES User Codes can be 3 to 6 digits in length Codes beginning with 0 zero can be programmed but they will not operate the panel this is an alternative method for disabling user codes The MEMORY E function is recommended for deleting user codes User Code 1 Master Code can be changed but it can not be deleted The MEMORY E sequence simply reverts User Code 1 back to factory default of 123 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected To clear all codes except the Installer Code enter P97E 3E in Installer Program mode See Page 45 Open Close reports are identified by user number when the control panel is central station monitored Shortcut arming ARM E if enabled is sent as User 25 RELATED OPTIONS Options P11E P25E allow the programming or deletion of the 15 keypad codes and also setup the Extra Options for user code slots programmed with a Radio Key PROGRAMMING SEQUENCE 1 Press P user number option 11 25 E The existing keypad code will be displayed out one digit at a time on the keypad ins 2 Press new code E new code again E e The new keypad code will be displayed on the keypad One beep will sound on the first entry of the new code three beeps will sound on the successful second entry of the new code EXAMPLE To program user c
27. box tamper or external tamper Note The panel will open The R8 will then be in Installer Program Mode remain in Installer Program Mode indefinitely USING THE KEYPAD The panel must be Disarmed 1 Press P MASTER CODE E The keypad will respond with 3 beeps J JJ This is User Program Mode PROGRAM light is ON 2 Th INSTALLER CODE Factory default Mond P l 1 Master Code 123 The keypad will respond with 3 beeps J JJ This is Installer Program Mode PROGRAM light is Factory default FLASHING Installer Code 00000 HOW TO EXIT PROGRAM MODE 1 Press P then E This is Operating Mode PROGRAM light is OFF Ness R8 Installation and Programming Manual ID PROGRAMMING POOE PO1E VOICE DIALLING TELEPHONE NUMBERS 1 amp 2 PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT Both Telephone Numbers blank NOTES These program options can also be accessed by pressing POE and P1E The leading zero is not mandatory RELATED OPTIONS e P70E P71E Central Station Telephone Numbers 1 4 2 page 36 Ness Voice Dialling format see page 47 Dialling Sequence page 47 GENERAL NOTE Program options POOE to PO9E can also be accessed by pressing POE to P9E The leading zero is not necessary These phone numbers are used to report alarms in Ness Voice Dialling format and can be programmed from User Program mode or Installer Program mode Itis not necess
28. dio Key Arming Warning enabled Default OFF PROGRAMMING SEQUENCE 1 Press P68E 2 Press 4E to toggle the option on or off Zone light on indicates the option is enabled Ness R8 Installation and Programming Manual EJ PROGRAMMING P70E P71E CENTRAL STATION TELEPHONE NUMBERS 1 amp 2 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Both Telephone Numbers blank NOTES e If P70E or P71E is programmed non blank then Ness Voice Dialling format is disabled POOE PO1E RELATED OPTIONS e POOE PO1E Ness Voice Dialling Format Telephone Numbers 1 amp 2 page 20 P86E 1E Disable Dialler page 41 Dialling Sequence page 47 The telephone numbers programmed at P70E P71E are used to report alarms to a central station in Contact ID format It is not necessary to program a reporting format Contact ID format is automatically selected when alarm reports are sent to the Central Station telephone numbers PROGRAMMING SEQUENCE 1 Press P70E or P71E e The existing telephone number is displayed e It is not necessary to wait for the display sequence to end You can interrupt the display by entering the new telephone number 2 new telephone number E The new telephone number is displayed EXAMPLE To program Central Station Telephone No 1 to be 03 1234 1234 Press P70E 0312341234E TO CLEAR A TELEPHONE NUMBER To clear a telephone number enter the MEMORY key
29. dio key is pressed The Radio Signal Strength Test can be used to test the radio signal from any Ness radio device The strength of the radio signal received is displayed on the zone lights 1 9 and beeped by the keypad The higher the number displayed and beeped the stronger the signal received Use POBE OE to test Radio Keys press Panic button Note that in this mode the R8 will respond to radio signals from any programmed radio device To avoid confusion from multiple radio signals this test is best performed while standing out of range of any programmed radio PIRs Use PO8E 1E 8E to test the signal strength of a specific radio device on zones 1 8 TO RESET THE TEST The last signal strength tested remains flashing on the display Press keypad E or Radio Key ON button to exit from the current test The panel is then ready for another radio test To completely exitthe Radio Signal Strength test simply go to another programming option or exit Installer Program Mode P E EXAMPLE TO TEST THE SIGNAL STRENGTH OF A RADIO PIR ON ZONE 2 1 Press PO8E 2E Radio icon and numeric icon 2 is flashing waiting for radio data 2 Trigger the radio device on zone 2 3 The display will alternate flashing signal strength value and radio key detector slot number E g The signal strength will be flashed on the display and the panel will beep signal strength value Then the radio icon and detector key number will be on steady
30. disabled ARM USER CODE E ON Shortcut enabled ARM E Default ON PROGRAMMING SEQUENCE 1 Press P62E 2 Press 1 5 E to toggle each option on or off Zone light s on indicates which option s are enabled SIREN BURST ON AUTO EXCLUDE P62E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 7 0N Enabled RELATED OPTIONS P60E 6E Auto Exclude Zones This option enables the 2 second siren burst at end of Exit Time which indicates a zone s has been Auto Excluded The siren burst is a low volume output from the onboard siren and the external siren PROGRAMMING SEQUENCE 1 Press P62E 2 Press 7E to toggle the option on or off Zone light on indicates the option is enabled Ea Ness R8 Installation and Programming Manual PROGRAMMING P64E 1E 8E MISCELLANEOUS OPTIONS 2 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E ON 3E not used 4E OFF 5E not used 6E ON 7E OFF 8E OFF PROGRAMMING SEQUENCE 1 Press P64E 2 Press 1 8 E to toggle each option on or off Zone light s on indicates which option s are enabled P64E 1E BRIEF MONITOR ALARM This option programs the behaviour of alarms in Monitor Mode OFF NORMAL MONITOR ALARMS Outputs are on for the Siren Reset Time and dialler reporting is enabled ON BRIEF MONITOR ALARM Outputs are on for 2 seconds internal piezo at half volume strobe
31. e 1 will start flashing 100 663 2 Connectthe 9V battery to the Radio PIR Ness R15 Radio PIR TO DELETE A RADIO DEVICE a To delete an existing Radio Device press PO9E select the zone number to delete 1E 8E then press PO9E again K EXAMPLE To delete the radio device programmed on zone 1 Press POSE 1E POSE 100 691 Ness R12 Radio PIR 100 662 Ness RR1 Radio Reed Switch Ness R8 Installation and Programming Manual Es PROGRAMMING PROGRAM RADIO KEYS PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT No radio keys programmed NOTES RELATED OPTIONS P11E P25E Program user codes Extra Options For Radio Codes page 25 The R8 will accept up to 14 Ness Radio Keys to be used for remote control wireless Arming Disarming and Panic functions Radio Keys are programmed to one of the 15 User Code slots with the easy to use radio Learn mode A User Code slot can be either a keypad code or a radio key code not both User Code 1 is always a keypad code PROGRAMMING SEQUENCE 1 Press P10E The RADIO icon will turn on and zone numbers 2 15 will show which user code slots have radio devices programmed 2 Press user number 2 15 E e The selected user number is flashing The user slot is in learn mode Along beep means the Radio Key may already be programmed to another user slot 3 Press the required Radio Key button to send the Learn message See How To Send The Learn Me
32. eporting is enabled Default ON P75E 4E REPORT FIRE ALARM OFF Fire Alarm reporting is disabled ON Fire Alarm reporting is enabled Default ON P75E 5E REPORT TAMPER ALARM This option applies to panel tamper and external tamper OFF Tamper Alarm reporting is disabled ON Tamper Alarm reporting is enabled Default ON P75E 6E Not used P75E 7E REPORT KEYPAD TAMPER ALARM Reports entry of consecutive invalid codes in Armed mode alarm on 4th failed attempt OFF Keypad Tamper Alarm reporting is disabled ON Keypad Tamper Alarm reporting is enabled Default ON P75E 8E REPORT EXIT FROM INSTALLER MODE OFF Exit From Installer Mode reporting is disabled ON Exit From Installer Mode reporting is enabled Default OFF PROGRAMMING SEQUENCE 1 Press P75E 2 Press 1 8 E to toggle each zone on or off Zone light s on indicates which option s are enabled ES Ness R8 Installation and Programming Manual PROGRAMMING REPORT MISCELLANEOUS RESTORALS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 8 ON All Miscellaneous Alarms report Restorals RELATED OPTIONS P75E Report Miscellaneous Alarms This option selects the miscellaneous alarms which will report Restorals by dialler See P75E page 38 for a list of Miscellaneous Alarms PROGRAMMING SEQUENCE 1 Press P77E 2 Press 1 8 E to toggle each zone on or off Zone light s
33. er PANIC button is pressed and held for 1 5 seconds PANIC Radio Press and hold the device PANIC button for the required length of time DURESS Keypad Enter a valid code prefixed with a 9 The response is the same as for a keypad Panic alarm but no sirens or strobe are active DURESS Radio With a radio key programmed as Duress press and hold the device PANIC button for the required length of time No sirens or strobe are active MEDICAL Keypad Press and hold Right Hand keypad Star key for 2 seconds The keypad beeper will sound 8 warning beeps The dialler reports a Medical alarm if enabled by P75E 2E MEDICAL Key With a radio key programmed as Medical press and hold the device PANIC button for the required length of time FIRE Keypad Press and hold Left Hand keypad Star key for 2 seconds This triggers the fire siren sound and the dialler reports a Fire alarm if enabled by P75E 4E RADIO SUBSTITUTION 1 CODE GRABBER A code grabber may be used to capture a transmitted user message and re transmit a fixed copy of this message in an attempt to defeat the system If two consecutive identical valid encrypted messages are received a minimum time apart the alarm is raised 2 ENCRYPTION HACKING In this case an attempt is made to crack the encrypted changing part of a message using multiple transmissions If 20 messages are received with a valid ID but fail decryption the alarm
34. es all Radio Zones programmed by option PO9E PROGRAMMING SEQUENCE 1 Press P97E 2 Press 2E Factory defaults are restored P97E 3E FACTORY DEFAULT USER CODES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable This option erases all Keypad Codes and Radio Key codes PROGRAMMING SEQUENCE 1 Press P97E 2 Press 3E Factory defaults are restored Ness R8 Installation and Programming Manual ES PROGRAMMING P9E PROGRAM THE INSTALLER CODE PROGRAM MODE LEVEL Programs the installer code This code can be 3 to 6 digits long Installer Remote by PC The factory default installer code is 000000 FACTORY DEFAULT 000000 PROGRAMMING SEQUENCE 1 Press P 99 E NOTES e The existing installer code will be displayed The Installer code cannot 2 Press new installer code E new installer code again E begin with the digit O zero The new installer code will be displayed One beep will sound on the first entry of the new code three The Installer code can be beeps will sound on the second entry of the new code if the code changed but it cannot be was successfully programmed deleted Any attempt to delete the installer code will make it revert back to the factory default of 000000 ES Ness R8 Installation and Programming Manual DIALLER OPERATION DIALLING SEQUENCE The dialler follows the re dial procedure shown until the message is success
35. ess Radio Keys All Ness supervised and encrypted radio devices are supported There is even a Doorbell feature with selectable tunes when used with the Ness Radio Doorbell transmitter In addition to radio devices the R8 has 1 hardwired zone and 1 hardwired tamper input for connection of a wired detection device and external siren cover tamper switch The built in piezo siren provides high volume audible warning The R8 also has Siren Piezo and Strobe outputs for additional hardwired noisemakers The R8 has a number of sophisticated power saving features designed to provide at least 48 hours service running on the backup battery alone This includes one full alarm condition with sirens strobe and dialler The built in dialler uses Contact ID format for central station monitoring as well as audible monitoring to any telephone The user can also dial into the system for remote arming and disarming over the telephone line SPECIFICATIONS RETO LES aora ro 8 Max Radio Keys 14 Hardwired zones 1 Hardwired tamper zones 1 Radio compatibility Ness supervised amp encrypted radio devices Dialler format Contact ID amp Audible Pulse On board Keypad Backlit programming amp user functions ECO High contrast icon display Puna ees 240V AC output 17V AC 300mA Quiescent current draw 10 mA in p
36. ess radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires NESS RADIO PIRS Y Ness Radio R15 PIR Passive n y Infrared and Ness R12 Radio PIR F for wireless motion detection Can be used in combination with Ness hardwired detectors in areas where it is not possible to install wires Includes long life lithium battery Ness R12 Radio PIR The Ness Radio PIR Pet Aware model detects humans but is immune to household pets Allows you to protect your home with your pets inside Ness R15 Radio PIR amp Ness Pet Aware Radio PIR wu we PET AWARE 9I NESS RDB RADIO DOORBELL 0 The Ness Radio Doorbell requires almost no installation Long life lithium battery powered simply screw it to the wall The doorbell chime is heard through the R8 panel onboard siren Choose from one of 9 doorbell tunes built in to the R8 panel Ness R8 Installation and Programming Manual NEZ R8 NESS R8 OPTIONS SUMMARY Pave tof4 OPTION No DESCRIPTION DEFAULT PAGE Voice Dialling Format Tel No 1 Voice Dialling Format Tel No 2 Doorbell Volume Doorbell Tune Radio Signal Strength Test OE Radio Key test Program Radio Devices none Program Radio Keys none P11E Program Master Code Keypad Code 1 P12E P25E Program Keypad Codes 2 15 Entry Delay Time Exit Delay Time Siren Reset Time Instant Zone
37. f the line fault continues for 2 minutes then the keypad beeps a warning OFF Telephone Line Monitor disabled ON Telephone Line Monitor enabled PROGRAMMING SEQUENCE 1 Press P89E 2 Press 5E to turn the option on or off Zone light s on indicates the option is enabled UP DOWNLOAD OPTIONS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E not used 3E OFF 4E OFF NOTES Option P90E 1E Remote Access applies only to upload download by computer and modem If PSOE 1E is disabled remote Arm Disarm is still available if options PSOE 3E and or 4E are on and P91E is not zero These options enable remote upload download features P90E 1E REMOTE ACCESS When selected on this option allows the panel to be remotely upload downloaded by a remote computer OFF Remote Access is disabled ON Remote Access is enabled Default OFF P9OE 2E Not used PSOE 3E REMOTE ARMING Allows the remote Arming of the control panel using a standard DTMF telephone or mobile phone OFF Remote Arming is disabled ON Remote Arming is enabled Default OFF P9OE 4E REMOTE DISARMING Allows the remote Disarming of the control panel using a standard DTMF telephone or mobile phone OFF Remote Disarming is disabled ON Remote Disarming is enabled Default OFF PROGRAMMING SEQUENCE 1 Press P90E 2 Press 1 4 E to toggle each zone on or off Zone
38. fully reported The dialler cycles around the Panel telephone numbers skipping numbers not programmed If P70E or P71E are programmed then the Voice Dialling numbers POOE and PO1E are ignored A successful report is defined as a report which has been kissed off by the Central Station or by a hash tone in the case of Audible Format dialling to a private number 1 Dial Central Station Ph No 1 P70E and report alarms in Contact ID format If not kissed off 2 Dial Central Station Ph No 2 P71E and report alarms in Contact ID format 3 If P70E and P71E are blank dial Voice Dialling Ph No 1 POOE and report alarms in Ness Voice Dialling format If not kissed off 4 If P7OE and P71E are blank dial Voice Dialling Ph No 2 PO1E and report alarms in Ness Voice Dialling format 4 Accumulate maximum of 15 failed attempts 5 Attempt to dial unsuccessful numbers a second time after 30 seconds a total of 10 attempts 6 Wait 5 minutes then subsequent attempts are 1 hour apart 7 Amaximum of 15 dial attempts for the same event 8 New events re start the sequence at 1 No more than 20 dial events will be reported between each disarming of the panel MESSAGE QUEUE The panel places event reports in a queue Multiple simultaneous reports or reports previously unsuccessfully dialled will be included in the current call The oldest report on the queue is sent first If the queue is full 8 messages a new repo
39. he MEDICAL key for at least 2 seconds right hand STAR key The keypad beeper will sound 8 warning beeps The dialler reports a Medical alarm if enabled by P75E 2E OFF No Keypad Fire Alarm ON Keypad Fire Alarm is enabled Default OFF Ness R8 Installation and Programming Manual EJ PROGRAMMING RADIO JAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E ON NOTES Radio Jamming and Radio Substitution alarms if enabled are reported to the central station and displayed by the RADIO icon on the LCD display P65E 1E RADIO JAMMING ALARM The R8 will raise a radio jamming alarm if 30 seconds of continous in band radio signal is detected Note The R8 needs to be powered up for a minimum of 10 minutes to obtain a no radio signal reference level before it is able to detect a radio jamming signal OFF Radio Jamming Alarm disabled ON Radio Jamming Alarm enabled Default OFF P65E 2E RADIO SUBSTITUTION ALARM The Radio Substitution alarm helps protect against 1 Code Grabber A code grabber may be used to capture a transmitted user message and re transmit a fixed copy of this message in an attempt to defeat the system If 2 consecutive identical valid encrypted messages are received a minimum time apart the alarm is raised 2 Encryption Hacking In this case an attempt is made to crack the encrypted changing part of a message using multiple transmis
40. hting or press E to manually restore backlighting Default OFF P60E 8E DISABLE ONBOARD SIREN OFF Onboard Siren enabled ON Onboard Siren disabled When the onboard siren is disabled keypad beeps are still active but are disabled during an alarm condition Keypad beeps will be reactivated on the next disarm Default OFF PROGRAMMING SEQUENCE 1 Press P60E 2 Press 1 8 E to toggle each option on or off Zone light s on indicates which option s are enabled Ness R8 Installation and Programming Manual EB PROGRAMMING OPERATION SHORTCUTS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON 2E ON 3E ON 4E not used 5E ON Some keypad operations can be programmed to operate with or without a User Code P62E 1E MEMORY DISPLAY SHORTCUT To enable or disable the View Memory shortcut OFF Shortcut disabled MEMORY USER CODE E ON Shortcut enabled MEMORY E Default ON P62E 2E ZONE EXCLUDE SHORTCUT To enable or disable the Zone Exclude shortcut OFF Shortcut disabled EXCLUDE USER CODE E ON Shortcut enabled EXCLUDE E Default ON P62E 3E MONITOR MODE SHORTCUT To enable or disable the Monitor Mode shortcut OFF Shortcut disabled MONITOR USER CODE E ON Shortcut enabled MONITOR E Default ON P62E 4E Not used P62E 5E ARMING SHORTCUT To enable or disable the Arming shortcut OFF Shortcut
41. ible Visual feedback danimi innan a piinia 10 11 User Tests avis etes a an nth t me LEE tes o f 11 OPERATION atout e ik een boa dtes oett 12 Operation S tmimaly vies ices Gt Dar e D e n eo qe dde E ee eee 13 Alarmi Type Descriptloris 22 een ccrte t td t v E e dee bus 14 System Alarm Descriptions esessssssseseseeseeeeeenee nnnm 15 Quick Start Panel Programming eseseeeeeenneennenen nennen 16 Quick Start RADIO Programming essen 17 PROGRAMMING anat RE Eee El ne Ee ee eats 19 How to enter Program Mode sssseeeneemmeeeeem rennen 19 PANEL PROGRAMMING OPTIONS seem nennen 20 35 DIALLER PROGRAMMING OPTIONS sse 37 43 FACTORY DEFAULT OPTIONS essen nennen aa enne 45 CENTRAL STATION MONITORING essen nennen nennen nnne 48 Contact ID reporting codes ssssssseeneenenenenene nennen nnne neni 48 Ness ACCeSSOMGS d A 50 Ness Radio Produc inicia AAA ee 51 PROGRAM OPTIONS SUMMARY cocccccccccccccccocconcnnnonnnn conc nan cnn non nan cnn cnn narnnn nan nrn cnn 52 55 INTRODUCTION The Ness R8 is a new and unique fully self contained radio control panel The panel has a built in keypad for programming and user operation a built in piezo siren built in LCD display built in radio receiver built in battery backup and built in dialler The R8 supports up to 8 Ness radio PIRs and up to 14 N
42. in place of the telephone number E g to clear Central Station Telephone Number 1 press P7OE MEMORY E SPECIAL CHARACTERS Special characters such as Pauses star or hash characters can be included in atelephone number dialling sequence by using the keys in the table below SPECIAL CHARACTER KEYPAD KEY KEYPAD DISPLAY PAUSE 1 6sec ARM 10 Star MONITOR 11 Hash EXCLUDE 12 EJ Ness R8 Installation and Programming Manual PROGRAMMING P72E CLIENT ACCOUNT NUMBER PROGRAM MODE LEVEL The 4 digit Client Account Number identifies the panel to the central Installer Remote by PC station when reporting alarms in Contact ID format The number FACTORY DEFAULT can be entered and reported in Decimal or Hex 0000 PROGRAMMING SEQUENCE 1 Press P72E The digits of the existing value will be displayed 2 Press new account number E The digits of the new value will be displayed EXAMPLE To program the Account Number to be 1234 P72E 1234E ACCOUNT NUMBER DIGITS HEX KEYPAD KEYPAD The Client Account Number is Wh dn normal entered in Decimal using B Star left or righ 11 keypad digits 0 9 C ARM 12 D MONITOR 13 If HEX digits are required use this E EXCLUDE 14 table when programming F MEMORY 15 P74E REPORT ZONE ALARMS PROGRAM MODE LEVEL This option selects the zones which will report alarms by dialler Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE 1 8 ON All zones report 1
43. ination microwave and passive infra red detector This combination of detection technologies virtually eliminates the possibility of unwanted alarms but faithfully detects humans PetAware model available QUANTUM 360 Ceiling mounted 360 passive infra red detector with selectable pulse count and sensitivity Provides 8 metre coverage mounted at standard 2 4 metre ceiling height PET AWARE DETECTORS The Ness Quantum Pet Aware PIR Pet Aware Radio PIR and the Pet Aware DUAL are able to discriminate between household pets and unwanted human intruders allowing you to secure your home with your pets indoors w PET AWARE SIRENS The range of warning devices includes horn speakers polytough siren covers internal screamers and satellite sirens with their own battery backup CCTV The Ness range of Closed Circuit TV equipment includes Dome cameras B W or Colour cameras Miniature hidden cameras Monitors even digital video recorders and remote telephone video systems SWITCHES A variety of switches are available for protecting doors and windows The line up includes surface and flush mount reed switches emergency buttons roller door reed switches and the unique Nessensor vibration sensor for highly effective perimeter protection EJ Ness R8 Installation and Programming Manual RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wi
44. internal antenna The external antenna can be fitted at the installer s discretion in cases where its reception pattern may better suit the local radio environment Ness R8 Installation and Programming Manual CONNECTION DIAGRAM Bottom l j o FRONT H HOUSING rear m m l p M O INTERNAL TAMPER 3 Ral SWITCH 2 o zs Battery D fu 3 p n MAIN BOARD o o ONL O zh TERMINAL Segesaesesoe ois EXE XS CABLE ENTRY Q a E 12V 0 8AH BATTERY E BACK HOUSING O MOUNTING HOLES fi TI Slotted x 4 ERE ui d WIRING HARDWIRED ZONE 2K2 END OF LINE OV ZONE N O TAMPER SWITCH 761 002 Colour BLACK Supplied with Ness siren covers TAMP sm l STROBE LIGHT NOI 300 Max Qty 1 EXTERNAL SCREAMER 100 172 Max Qty 1 SIREN PIEZ PIEZ EXTERNAL HORN SPEAKER NOI 110 Max Qty 1 PLUG PACK 17VAC 300mA Supplied 0009909090990099 am Lac 4b Lsm a ra q O a Ee ra W E ES Ness R8 Installation and Programming Manual INPUTS OUTPUTS INPUTS ZONE Zone input for optional hardwired detection devices Operates in series w
45. is raised Arming and disarming resets this count The dialler reports a radio jamming radio substitution alarm RADIO JAMMING After accumulating a no radio signal reference level 10 minutes after power up the system will raise a radio jamming alarm if 30 seconds of continuous in band radio signal is detected DIALLER LINE FAULT Indicates minimum telephone line DC voltage was not detected for a 2 minute period If Telephone Line Monitor is enabled flash the LCD LINE icon and beep keypad ES Ness R8 Installation and Programming Manual SYSTEM ALARM DESCRIPTIONS System Alarm indication icons are active in all Operate modes All system alarms sound beeper until the E key is pressed If the panel is armed the beeper is sounded on disarm While the alarm persists the beeper is sounded on each disarm System alarms can be reported if the system is monitored by a central monitoring station ALARM TYPE DESCRIPTION LOW BATTERY Radio Key Radio Panic Radio Doorbell Indicates a low battery condition A low battery alarm occurs when the key operates Flash the LCD BATTERY and RADIO icons after a transmission from device with low battery turn them off when a transmission from a device without a low battery is received LOW BATTERY Radio PIR Indicates a low battery condition A low battery alarm occurs when the detector operates Flash the LCD BATTERY RADIO and zone number icons LOW BATTERY
46. is volume level 1 lowest to 4 highest PROGRAMMING SEQUENCE 1 Press POSE Existing value is displayed 2 ENTER NEW VALUE E New value is displayed EXAMPLE To program Doorbell Volume to be Level 2 Press POSE 2E DOORBELL TUNE PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 3 Ding Dong NOTES RELATED OPTIONS Doorbell Volume PO5E The R8 has nine built in doorbell tunes to choose from The doorbell is activated by the optional 100 056 Radio Doorbell transmitter Most Ness transmitters can be programmed to operate the Doorbell function see page 25 Extra Option for Radio Keys PROGRAMMING SEQUENCE 1 Press PO6E Existing value is displayed 2 ENTER NEW VALUE E New value is displayed EXAMPLE To program Doorbell Tune to be Tune 1 Westminster Press POGE 1E AVAILABLE TUNES Westminster Westminster 4 notes only Ding Dong Ding Dong Repetitive Star Spangled Banner Fur Elise Home Sweet Home Green Sleeves Chime OONOAARWND Ness R8 Installation and Programming Manual ES PROGRAMMING PO8E RADIO SIGNAL STRENGTH TEST PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0 Radio Key test NOTES The signal strength beeps will sound only the first time the radio device is activated The signal strength and device number remains flashing on the display until E is pressed again or the ON button of a valid ra
47. ith any radio devices on zone 8 The input must be terminated with a 2K2 2200 ohm end of line EOL resistor even if unused TAMP 24hr input for connection of external tamper switches This input operates in series with the internal tamper switch The input must be terminated with a 2K2 2200 ohm end of line EOL resistor even if unused AC EARTH AC power input and earth connection Use the supplied 17V AC 300mA plug pack OUTPUTS SIREN Timed siren output for connection of maximum one 1 8 Ohm horn speaker STR Output for connection of 1 x NOI 300 Ness strobe light As a power saving feature the strobe output times out after 11 hours If mains power is off the output will time out after 1 hour PIEZ Timed output for connection of maximum 1 x 12V screamer Ness Part No NOI240 NOI 230 100 238 or 100 172 ONBOARD SIREN BUILT IN The onboard piezo siren is an integral part of the R8 electronics It is used for keypad beeps doorbell chime arm disarm chirps and internal siren on alarm The internal Siren can be disabled by program option P60E 8E When the Internal Siren function is disabled the onboard siren still outputs keypad beeps and other audible features Ness R8 Installation and Programming Manual EN R8 KEYPAD AUDIBLE 8 VISUAL FEEDBACK The R8 onboard keypad provides the facility for user level and installer level programming and all user operation and emergency functions The keys are sof
48. light s on indicates which option s are enabled Ness R8 Installation and Programming Manual 43 PROGRAMMING PoE ETE PROGRAM MODE LEVEL Sets the number of double rings before an incoming call is Installer Remote by PC answered This is used for Remote Access FACTORY DEFAULT Programmable from 1 to 16 rings Enter a value between 1 and 16 1 1 double ring NOTES PROGRAMMING SEQUENCE 1 Press P91E The digits of the existing value will be displayed 2 Press required rings E The digits of the new value will be displayed 44 Ness R8 Installation and Programming Manual PROGRAMMING CLEAR MEMORY PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable This option erases the Event Memory as well as memory locations where events and time stamps are stored for uploading status PROGRAMMING SEQUENCE 1 Press P96E The Event Memory is erased P97E 1E FACTORY DEFAULT PANEL OPTIONS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable This option erases all program options and restores the factory default values The exceptions are Radio Zones and User Codes see P97E2E and P97E3E PROGRAMMING SEQUENCE 1 Press P97E 2 Press 1E Factory defaults are restored P97E 2E FACTORY DEFAULT RADIO ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable This option eras
49. mum of wiring If an external siren or strobe light is not being used the only essential wiring is connection of the plug pack The steps below will show you how to program one 100 663 or 100 691 Radio PIR and one 100 664 Radio Key O To enter Installer Program Mode To enter Installer Program Mode on initial power up apply power with the internal tamper open lid open or the external tamper open Or if you have powered up with all tampers sealed see below then press Cem ees ODDO i POVDOVOWYU E 123 is the factory default This is User Program 000000 six zeros is the factory default This is Installer Program Master Code Mode The PROGRAM Installer Code Mode The PROGRAM icon is on steady icon is flashing To program a Radio PIR Example to program a Radio PIR on zone 1 v Press POE then press Me o POSE is the option for Learn mode for zone 1 programming Radio Devices 4 The RADIO icon will be on and the number 1 will be flashing j The zone numbers for radio devices already programmed will be ON Insert the battery of the Radio PIR to be programmed Beep beep 3 beeps will be heard if the RADIO PIR was successfully learned Zone icon 1 will then be on steady To program a Radio Key Example to program a Radio Key to user slot 2 Press DOVE then press Qe P10E is the option for Learn mode for User 2 programming Radio Keys The RADIO icon will be on and the
50. nds Turns on all LCD icons while the button is pressed Ness R8 Installation and Programming Manual ES OPERATION OPERATING MODES The Ness R8 will operate in one of the following modes ARMED The system is On and ready to detect intrusion DISARMED The system is Off This is the normal mode when the premises are occupied Day Zones and 24 Hour Zones if configured are active DAY MODE The system is Disarmed and a zone or zones have been setup to create an alarm when activated Often used as a doorway alert in a shop See P53E Day Zones MONITOR MODE Allows the system to be partially Armed For example in a house to allow all perimeter zones doors and windows to be Monitored armed at night See P51E Monitor Zones 24HR ZONES Zones that have been setup to be active in any mode Usually used for Tamper switches and Panic buttons See P52E 24hr Zones DOORBELL The radio Doorbell operates in any panel mode The doorbell can be triggered using the 100 056 Doorbell transmitter Most Ness transmitters can be programmed to operate the Doorbell function see page 25 Extra Option for Radio Keys See page 21 for doorbell volume and selectable chimes settings KEYPAD DISPLAY IN MEMORY REVIEW MODE EVENT DISPLAY ICONS Arm ARMED Disarm blank Auto Exclude Zone EXCLUDE 1 8 Mains Fail MAINS Panel Panic Medical Fire EXCLUDE Battery Fail BATTERY Line Fault
51. ne Auto Exclude q 380 Ozz Exit Install mode 1 306 035 Test Report 1 602 063 ES Ness R8 Installation and Programming Manual RELATED OPTIONS P91E Required rings P90E 3E Remote arming P90E 4E Remote disarming NOTES If the R8 does not receive remote commands for periods longer than 60 seconds it will assume that the call is finished and it will hang up AUDIBLE FEEDBACK JJ 3 BEEPS Valid command user code J J 1 LONG BEEP Invalid command or user code try again SUMMARY OF TELEPHONE COMMANDS 0 PREPARE TO RECEIVE COMMANDS User Code st VERIFIES THE USER 4 ARM 2 DISARM s HANG UP DIALLER OPERATION REMOTE TELEPHONE ARM DISARM The R8 can be armed and disarmed remotely using a standard fixed or mobile telephone To maintain panel security remote operations can only be activated after entering a valid user code To operate the R8 by telephone you need a DTMF capable telephone a valid User Code and you must know the Telephone number of the line to which the R8 is connected Program options P90E 3E and or 4E must be on to enable remote arming and or disarming Option P91E required rings to answer must be a value other than zero SEQUENCE OF OPERATION 1 Phone the R8 telephone number and listen for the required number of double rings and then hang up 2 Call the number again within 60 seconds 3 The R8 will answer the second call immediately sound
52. ns 2E Factory Default Radio Zones 3E Factory Default User Codes P99E Program Installer Code 000000 46 Ness R8 Installation and Programming Manual E This page is intentionally blank
53. ode 2 to be 1234 1 Press P12E 1234E 1234E TO DELETE A CODE To delete a User Code enter the MEMORY key in place of the code Example To delete User Code 2 P12E MEMORY E For a list of user option numbers see the USER CODE OPTIONS TABLE on page 25 Open Close reports if enabled by your installer are identified by user number if the control panel is central station monitored P10E Program Radio Keys ES Ness R8 Installation and Programming Manual PROGRAMMING ENTRY DELAY TIME PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 20 20 seconds NOTES Programmable range is 1 99 seconds To view the programmed value without making changes press P26E The Entry Delay Time is the time given to Disarm the Panel on entry through an entry delay zone PROGRAMMING SEQUENCE 1 Press P26E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program the entry delay time to be 25 seconds P26E 25E EXIT DELAY TIME PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 60 60 seconds NOTES Programmable range is 1 99 seconds To view the programmed value without making changes press P28E The Exit Delay Time is the time given to secure and exit the premises after the R8 is Armed All zones except 24hr zones are inactive during the Exit Delay time PRO
54. ower save mode if mains is off Built in backup battery 12 volt 0 8 Amp hour sealed lead acid Dynamic Battery Test Every Hour and on arming disarming USO US 2A resettable sirens 2A resettable Reset output built in piezo and strobe SICA 1 x 8 Ohm horn speaker On board piezo siren 110 dB Piezo output sss 12V DC 300mA max SOC 12V DC DNA 210 w x 145 h x 40 d mm ES Ness R8 Installation and Programming Manual COMPATIBILITY The Ness R8 supports all Ness radio devices as shown below All late model Ness transmitters send encrypted transmissions to prevent eavesdropping and substitution Ness fixed transmitters can send a regular supervision signal which the R8 monitors to ensure system security 00800008 100 665 100 664 100 067 100 283 100 056 100 662 100 691 100 663 100 001 RK1 RK3 RK4 RPB Radio RDB Radio RR1 Radio R12 R15 RKP Pendant Radio Key Radio Key Panic Button DoorBell Reed Switch Radio PIR Radio PIR Radio Keypad LJ RADIO RADIO KEYS RADIO PANIC RADIO DOORBELL ZONE INPUT HARDWIRE PLUGPACK Supplied EXTERNAL SIREN OUTPUT STROBE OUTPUT TAMPER INPUT MANMI PHONE LEAD Supplied INTERNAL PIEZO OUTPUT Ness R8 Installation and Programming Manual INSTALLATION INSTALLATION PROCEDURE 100 690 R8 The location of the main panel housing should be in an area PACKING LIST th
55. reless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door The Ness Radio Key provides the benefits of separate ON OFF and PANIC buttons in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel MADER AUSTRALIA ALMAS v NESS RK3 RADIO KEY Fully waterproof ultra slim 3 button Radio Key for remote control of the control panel With separate buttons for ON Arm OFF Disarm and PANIC functions Includes long life lithium battery NESS RK1 RADIO KEY PENDANT Fully waterproof pendant style 1 transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as 2 wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for medical alarm purposes Includes long life lithium battery NESS RR1 RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery NESS RADIO PRODUCTS NESS RKP RADIO KEYPAD l A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the Ness D16 D16 amp D24 control panels Md m woe Y Y 000 9 0 0 Also operates Monitor mode and Panic when used with the Ness D16 D24 panels The N
56. rt will overwrite the oldest report THE CURRENT DIALLER QUEUE IS CANCELLED AND THE DIALLER BUFFER IS ERASED ON ENTRY TO INSTALLER PROGRAM MODE NESS VOICE DIALLING a The dialler sends alarm reports to a private telephone mobile telephone or fixed telephone using Voice Dialling Telephone MOMTIRED TELEPHONE LINE ANY TELEPHONE numbers 1 and 2 POOE P01 E See page 20 If POOE or PO1E are programmed with a telephone phone number then alarms will be sent to that phone number s in Ness Voice Dialling format The word ALARM is repeated until the 4 DTMF key on the Voice Dialling format is telephone is pressed or 30 seconds expires If the key is not disabled tra Central pressed the number will be redialled Station telephone number is programmed The person receiving the call can then acknowledge kiss off BU RPOE OF PIE the alarm by pressing the key on their telephone Ness R8 Installation and Programming Manual 47 DIALLER OPERATION CENTRAL STATION MONITORING i E The dialler sends alarm reports to a central station using Central Station Telephone numbers 1 and 2 P70E amp P71E Page 36 MONITORED l TELEPHONE LINE MONITORING x PREMISES i ip STAND It is not necessary to program a reporting format Alarm reports are automatically sent in Contact ID format to the telephone numbers programmed at P70E and or P71E Events are reported to the central station using the Contact ID format
57. s Zones 3 8 Entry Delay Zones Zone 1 Handover Zones Zone 2 Reset Lockout Zones All zones Monitor Zones No zones 24hr Zones No zones Day Zones No zones Entry beeps not used not used Tamper Siren Lockout not used Auto Exclude Zones Keypad Backlight Blanking Disable onboard siren 52 Ness R8 Installation and Programming Manual RE R8 NESS R8 OPTIONS SUMMARY Pazo OPTION No DESCRIPTION DEFAULT PAGE P62E 1E Memory Display Shortcut ON 2E Zone Exclude Shortcut ON 3E Monitor Mode Shortcut ON 4E not used OFF 5E Arming Shortcut ON P64E 1E Brief Monitor Alarm 33 2E Brief Day Alarm 4E Siren chirps Arm Disarm 6E Keypad Panic Alarm 7E Fire Alarm 8E Medical Alarm P65E 1E Radio Jamming Alarm OFF 34 2E P67E Radio Supervision Time 24 hrs E ON 35 P68E 4 Radio Key Arming Warning OFF 35 36 P70E Central Station Telephone No 1 none Radio Substitution Alarm P71E Central Station Telephone No 2 none P72E Client Account No 0000 P74E Report Zone Alarms 1 8 All zones 37 37 P75E see next page Report Misc Alarms P76E Report Zone Restorals 1 8 All zones 37 VY These options are available in USER PROGRAM MODE V ALL options are available in INSTALLER PROGRAM MODE Ness R8 Installation and Programming Manual E INEA R8 NESS R8 OPTIONS
58. sions If 20 messages are received with a valid ID but fail decryption the alarm is raised Arming and disarming resets this count OFF Radio Substitution Alarm disabled ON Radio Substitution Alarm enabled Default ON PROGRAMMING SEQUENCE 1 Press P65E 2 Press 1 2 E to toggle each option on or off Zone light s on indicates which option s are enabled ET Ness R8 Installation and Programming Manual PROGRAMMING RADIO SUPERVISION TIME PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 24 24 hours NOTES RELATED OPTIONS P88E 6E Report Supervision Alarms The SUPERVISION TIME is the time allowed between radio transmissions received by the R8 from any Supervised Radio Detector The SUPERVISION TIME setting is from 1 to 168 hours Supervision is disabled by setting time of 0 zero PROGRAMMING SEQUENCE 1 Press P67E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program Radio Supervision Time to be 6 hours P67E 6E P68E 4E RADIO KEY ARMING WARNING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 4 OFF Disabled NOTES Setting this option on allows an external siren chirp warning if there is an unsealed zone when the panel is armed by a Radio Key otherwise only internal beeper warning is given OFF Radio Key Arming Warning disabled ON Ra
59. ssage Three beeps indicates the radio key has been successfully programmed EXAMPLE To program a Radio Key to user slot 2 Press P10E 2E then press and hold the PANIC button on the Radio Key TO DELETE A RADIO KEY To delete an existing Radio Key press P10E select the user number to delete 2E 15E then press P10E again EXAMPLE To delete the Radio Key on user slot 2 Press P10E 2E P10E 100 665 100 664 96 100 067 HOW TO RKI RK3 22 RK4 SEND THE Radio Pendant 9 Radio Key lt Radio Key LEARN Press button three times Press and hold PANIC Press and hold PANIC for 8 seconds for 8 seconds MESSAGE 100 001 100 283 100 056 RKP O RPB Radio v RDB Radio Keypad Panic Button Radio Door Bell Insert the battery or consult Press and hold for Press and hold for the Radio Keypad manual 8 seconds 8 seconds E Ness R8 Installation and Programming Manual FACTORY DEFAULT Extra Option 1E Panic is the factory default for all user slots NOTES When programming the Radio Doorbell 100 056 the Extra Option for that user slot must be 5E PROGRAMMING EXTRA OPTIONS FOR RADIO CODES Each user code slot has five Extra Options which control the behaviour of Radio Keys and the Radio Doorbell transmitter when they are programmed to a user code slot on the R8 The Extra Options are 1E Panic The Panic Button will trigger the Panic alarm default 2E Duress The Panic Button will trigger the Duress
60. t touch silicon rubber and are backlit for high visibility Any keypress will turn on the backlighting for 4 minutes 1234 6 9 10 11 12 13 14 1 v h lh r READY ARMED ARMA ALARM TANPE BACKLIT A E e LCD DISPLAY MONITOR BATTERY MANS EXCLUDE PROGRAM LINE FIRE MEDICAL PANIC ONBOARD SIREN FUNCTION BUTTONS PROGRAM ENTER BEEPER OUTPUT OUTPUT TYPE DESCRIPTION Keypad beeper a SHORT BEEP Keypad Acknowledge key press JJ 3 BEEPS RAPID Keypad Valid entry end of Exit Time 4 4 LONG BEEP Keypad Invalid entry 4 94 8 BEEPS RAPID Low battery AC Fail Medical Alarm 4 CONTINUOUS BEEPS Alarm Entry Delay etc Onboard Siren 1 CHIRP Arm External Siren output 3 CHIRPS Disarm Onboard Siren DOORBELL TONES The Doorbell has been pressed Onboard Siren SIREN BURST Zone Auto Exclude warning External Siren output Low Volume Onboard Siren SIREN CONTINUOUS Alarm condition Piezo output External Siren output Strobe output STROBE BURST Panel Armed or Disarmed STROBE CONTINUOUS Alarm condition Arm disarm chirps must be enabled 10 Ness R8 Installation and Programming Manual LCD DISPLAY KEYPAD DISPLAY IN OPERATING MODE AN Y DISPLAY OFF O ON lt FLASHING ZONES 1 8 Zone is sealed Zone is
61. tes which option s are enabled ES Ness R8 Installation and Programming Manual PROGRAMMING RESET LOCKOUT ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 8 ON All zones are Lockout zones NOTES This option applies to the RESET output the SIREN output always locks out RELATED OPTIONS P60E 4E Tamper Reset Lockout All zones can be programmed to Lockout i e cause the RESET OUTPUT to sound only once whilst the panel is armed The RESET OUTPUT is then locked out for that alarmed zone until entering a valid code has reset the panel PROGRAMMING SEQUENCE 1 Press P44E 2 Press 1 8 E to toggle each zone on or off Zone light s on indicates which option s are enabled MONITOR ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 8 OFF No Monitor zones RELATED OPTIONS P64E 1E Brief Monitor alarm This option selects which zones will be armed in Monitor mode Monitor zones allow you to Arm selected zones while others are ignored Typically used for perimeter zones such as windows and doors while you are at home Example Upstairs zones are Disarmed while downstairs zones are Armed in Monitor mode PROGRAMMING SEQUENCE 1 Press P51E 2 Press 1 8 E to toggle each zone on or off Zone light s on indicates which option s are enabled 24HR ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 8
62. to the Central Station that an alarm has been reset by a valid user Usually used in cases where Open Close reports are normally selected OFF A Cancel Report is sent when a Zone or Miscellaneous Alarm has been reset by a valid User Code or Radio Key disarming If enabled a cancel report will be sent after alarm Contact ID code 406 even if Open Close reports are disabled OFF Cancel Report disabled ON Cancel Report enabled PROGRAMMING SEQUENCE 1 Press P88E 2 Press 5E to turn the option on or off Zone light s on indicates the option is enabled P88E 6E REPORT SUPERVISION ALARMS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Report Supervision Alarms disabled RELATED OPTIONS P67E Radio Supervision Time This option enables the dialler reporting of Radio Supervision alarms OFF Report Supervision Alarms disabled ON Report Supervision Alarms enabled PROGRAMMING SEQUENCE 1 Press P88E 2 Press 6E to turn the option on or off Zone light s on indicates the option is enabled 42 Ness R8 Installation and Programming Manual PROGRAMMING P89E 5E TELEPHONE LINE MONITOR PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Telephone Line Monitor disabled NOTES When enabled the panel will test the telephone line every 20 seconds If the telephone line is not found the keypad LINE icon will commence flashing I

Download Pdf Manuals

image

Related Search

Related Contents

LES MORALISTES A LA TRAPPE - le site de Louis Van Delft  I MANUALE D`USO E MANUTENZIONE GB USE AND - NH  User Operation Guide  BK8500, BK8502, BK8510, BK8512, BK8514, BK8518, BK8520  BedienungsanleitungBedien - FLATLIFT® TV Lift Systeme    Navigation System  Teledyne 300M User's Manual  NetCONNECT 2.0 User Guide  Instructions de montage du nez Avbolt® Outils  