AfinionTM ACR • Quick Guide

image

Contents

1. Afinion ACR e Quick Guide TESTING PROCEDURE ar 1 A Pull the sampling device straight Fill the capillary touch the up from the Test Cartridge surface of the patient sample a or control b Fill it completely c Do not wipe off the capillary Touch for patient Insert the Test Cartridge with samples or touch i the barcode facing left for controls The lid opens automatically 7 Touch amp Jand enter Record the result when it appears patient ID or touch E on the screen and enter control ID e Touch _ to accept Touch to confirm Eg The lid opens automatically Axis Shield PoC AS Oslo Norway www axis shield poc com WE Replace the sampling device p immediately Analysis of the Test Cartridge must start within 1 minute Close the lid manually to start analysing Remove and immediately discard the used Test Cartridge Close the lid manually when the Analyzer is not in use GB 1115293 2007 05 Afinion ACR e Quick Guide Patient sample e Use random urine preferably first morning urine e Samples can be stored refrigerated 2 8 C for 5 days Do not freeze e Mix the sample well by inverting the vial 8 10 times before use Afinion ACR Control e Store the controls refrigerated 2 8 C Opened controls are stable for 8 weeks e The control can be used directly from the refrigerator e Mix the control well by inverting th
2. e vial 8 10 times before use e The measured values should be within the acceptable range stated in the Afinion ACR Control Package Insert Afinion ACR Test Cartridge e Store the test kit refrigerated 2 8 C until the expiry date e The Test Cartridge must reach a temperature of 20 30 C before use leave the unopened foil pouch on the bench for at least 15 minutes e Use the Test Cartridge within 10 minutes after opening the foil pouch e Hold the Test Cartridge by the handle Afinion AS100 Analyzer e Switch on the Analyzer and optionally enter the operator ID e Analyse patient samples and controls following the test procedure on the reverse side e An information code might be displayed during analysis The possible causes and actions to take are listed in the Afinion AS100 User Manual and the Afinion ACR Package Insert e Information codes specific for the Afinion ACR assay Code Cause 107 Creatine too high 108 Blood in the urine detected by the Analyzer Consult the Afinion user instructions for complete information BH e Afinion ACR Package Insert e Afinion ACR Control Package Insert e Afinion AS100 User Manual Axis Shield PoC AS Oslo Norway www axis shield poc com GB 1115293 2007 05

Download Pdf Manuals

image

Related Search

Related Contents

Impresoras portátiles Serie RJ - La necesidad de  取扱説明書 - 日本スティーベル  Philips Hospitality LED TV 32HFL4663D  Model 1020C Temperature Chamber Operation and Service Manual    FINEPIX REAL 3D W1 使用説明書/ソフトウェア取扱  Blossom  大和高田市文化会館舞台調光設備改修工事仕様書  Philips SA2313 1GB* Flash audio player  Blackberry 7100I Cell Phone User Manual  

Copyright © All rights reserved.
Failed to retrieve file