1. ENEN Portable Multi logger ZR RX40 ZR RX20 Dear KX Budde S Ie SEA AE AR AR AE leet pe PR j SPAN TRACE Free Running 1 sec DIV Ven Ze Heee em mm CH GROUP P Y POSITION MONITOR lt TIMEDIV gt SAMPLE 199ms ZONE dzone CURSOR DISPLAY ALARMI1T21314 NAVI REVIEW realizing 16 15 14 13 12 rT TT aa 200b 12 07 4 eecht 10 34 04 Free Running p H Standard 20 Channels Insulated amentals Versatility and Usability Secure Isolated Multi Input Multi input is possible for temperature humidity voltage logic and pulse Each channel is supplied with its own isolated circuit giving zero inter channel noise interference Maximum 200 Channel Expandability The terminal block just connect and go comes with 20 channels in standard configuration A maximum of 10 units can be connected to each logger easily creating a multi channeled measurement system to be used according to the number of channels needed Simple LAN Connection The embeded Web server function enables remote control from a web browser A USB connection means a greater array of measurements is possible Standard PC software is also included Supper Light Mobile Model Also Available Portable Multi Logger ZR RX20A E M 10 isolated channels Mi Multi channel input thermal resistance voltage etc
2. PC I F Functions Data transfer to the PC realtime memory Web server function Operation of ZR RX40 FTP function Transfers and deletes measured data from internal memory via network Data transfer to the PC realtime memory Data save Measured data Internal memory 3 5MB Flash memory Internal memory 12MB Flash memry functions or direct capture in the USB memory device or direct capture in the USB memory device Other Setup conditions copy of data screen can be saved in the internal memory or USB memory device Display 3 5 inch TFT color LCD QVGA 320 x 240 dots 5 7 inch TFT color LCD QVGA 320 x 240 dots Display Language Japanese English US English UK French German Chinese Korean Operating environment 0 to 40 C 30 to 80 RH 15 to 40 C when the battery 0 to 45 C 5 to 85 RH 15 to 40 C when the battery Withstand voltage 350 Vp p between input channel GND between each chs 1 minute Power supply Voltage AC adapter 100 to 240 VAC 50 to 60 Hz 9 DC input 8 5 to 24VDC Battery pack opitin Power consumption 28 VA or less when the AC adapter is used Weight 480g Excluding the AC adapter and battery 990g Including 1 terminal units Excluding the AC adapter and battery Measurement accuracy ZR RX20 ZR RX40 Commonness Humidity Sensor ZR XRH1 Option Voltage 0 1 of F S Item Description Ambient temperature 25 to 80C Thermocouple Measurement Temperature Range C Measureme Ambient humidity 0 to
3. MCompatible with USB flash drive W internal 3 5MB flash memory M3 5 inch TFT color LCD MEasy to navigate menus W6 hour battery option MMS3 screw terminal blocks Standard PC software channels Anyone Anytime Anyplace Portable Multi logger ZR RX40 Input signal Voltage Humidity omron List of features Maximum All channels Thermocouples TU LAN USB 200 channels isolated K J E T R S B N W maan function flash drive 12MB 5 7 inch Easy to 9 hour Display 16bit internal memory TFT LCD navigate menus battery switch resolution Advanced Fundamentals All channels isolated Each circuit is electrically isolated so that the different channels do not affect each other Conseguently there is no noise interference between the channels giving highly accurate and stable measurements Multi function input The temperature input supports thermocouples and resistance thermometer Furthermore in addition to temperature an array of measurements including humidity and voltage can be taken at once It also supports logic or pulse input input from external triggers as well as alarm signals output Analog signal input terminal pulse input Temperature Humidity Voltage In output Trigger input _JGND Switches between logic and pulse Detachable terminal blocks Expandable to 10 units option Optional parts needed when detaching or expanding Expandable up to 200 chan
4. to compare each measurement or observe the waveforms for each input signal 3 Hi Major functions Observation of wave forms is very convenient when there is much measurement data gt Quick call up ofthe cursor such as multi channel measurements multi measurements etc Also functions not available Special search function in standard software are provided such as directly dragging waveforms scales and cursors with a Osc sen save function CSV save function mouse so that extremely intuitive operability that far exceeds that of Re rrinting function conventional logger software is achieved p g H System Configuration Standard set ZR RX20A E Common options Special PC Software DC cable 2m Battery Pack Humidity Sensor 3m ZR SX10 ZR SC ZR XRB1 ZR XRH1 Utility disk QD O Sf CH Content of utility disk Tryout software full Special PC software Trial version activation USB memory AC adaptor AC cable Standard PC software eStart up guide manual PDF file ZR RX40 Special options Base Set ZR XRE1 a ZR RX40A E By o Extension Terminal Set 1 GB provided ZR XRT1 af EN sp ay Utility dek Logic Alarm Cable Content of utility disk ZR XRL1 Special PC software Trial version Standard PC software AC adaptor AC cable manual PDF file eStart up guide ZR RX40 Necessary option when channel is enhanced Item 20CH 40CH 100CH 200CH ZR RX40 Main unit 1 1 1 1 Base Se
5. 1 Special PC Software Wave Inspire RX ZR RX20 40 commonness ZR SX10 The temperature detector also abundantly does the lineup MExternal Dimensions Unit mm ZR RX20 ZR RX40 ZR RX40 Main body installation screw hole 4 2 M4 Depth 6 Portable Multi logger ZR RX20 RX40 d nnn f DRECK G e remm GR This document provides information mainly for selecting suitable models Please read the document User s Manual Z257 Z260 carefully for information that the user must understand and accept before purchase including information on warranty limitations of liability and precautions OMRON Corporation OMRON ELECTRONICS LLC industrial Gare ere Company One Commerce Drive Schaumburg Authorized Distributor Sensing Devices Division H Q A Gate EE Tel 1 847 843 7900 Fax 1 847 843 7787 Application Sensors Division Shiokoji Horikawa Shimogyo ku OMRON ASIA PACIFIC PTE LTD Kyoto 600 8530 Japan No 438A Alexandra Road 05 05 08 Lobby 2 Tel 81 75 344 7068 Fax 81 75 344 7107 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 Regional Headquarters OMRON EUROPE B V OMRON CHINA CO LTD Sensor Business Unit Room 2211 Bank of China Tower Carl Benz Str 4 D 71154 Nufringen 200 Yin Cheng Zhong Road Germany PuDong New Area Shanghai 200120 China In the interest of product improvement T
6. 100 RH R S 5 2 C Relative humidity measurement accuracy 3 RH 5 to 98 RH at 25 C 3 0 C Response time 15 sec 90 response when membrane filter is installed 0 05 of rdg 2 0 C Sensor output DCO to 1V S 300 lt TS lt 1760 C 0 05 of rdg 2 0 C External dimensions 14 x 80 mm excluding cable B 400 lt TS lt 600 3 5 C Cable length 3m 600 lt TS lt 1820 C 0 05 of rdg 2 0 C K 200 lt TS lt 100 0 05 of rdg 2 0 C 100 lt TS lt 1370 C 0 05 of rdg 1 0 C PC Software E 200 lt TS lt 1 0 05 of BAS Special PC Software ZR SX10 Standard PC Software 100 lt TS lt 800C 0 05 of rdg 1 0 C Wave Inspire RX Smart Viewer RX20 RX40 T 200 lt TS lt 100 0 1 of rdg 1 5 C OPTION Sold separately Trial version Enclosed in the ZR RX standard set 100 lt TS lt 400 C 0 1 0f rdg 0 5 C enclosed in the ZR RX standard set J 200 lt TS lt 100 2 7 C Standard Logging data display Real time PC data logging 100 lt TS lt 100 EL E ZR RX setting CV file conversion 100 lt TS lt 1 1009 0 05 of rdg 1 SS Direct drug amp move Scale change by numeric input N O lt TS lt 1300 C 0 1 of rdg 1 0 C Wave Scale batch change of all channels RX20 W O lt TS lt 2315 C 0 1 of rdg 1 5 C Operation Other Intuitive functions including Scale change of each channel by icon mouse wheel operation RX40 Resi
7. cate is requested when purchasing the Portable Multi logger the inspection date on the certificate will be the same as the manufacturing date If an inspection date that is close to the shipping date is required an extra fee and additional time will be required Ask your OMRON representative for details Freely compare and quickly decide Smart grouping amp multiple display O 3 step simple waveform observation vii n Multiple display N S gt d b S A E o y S search selected channels in one operation A Grouping is simple by drag and For each group a waveform screen can be displayed so observation of comparisons between groups is possible After the search the channels have selected drop into the created groups status E Acquisition condition setting 7 add Del Samy Search Analog Wave Name Color Input Name PCB1 DER TEMP Ti PCB2 at PCBS IC TEMP PCB1 IC2 TE TEMP T sii mn H IC VOLT Display for each PCB2_IC1_TE NE TEMP T mmm PCB2 IC2 TE TEMP T input signal Compare multiple boards target PCB1 ICi TE PCB3 1C1 TE muun TEMP T om PCB3 IC2 TE MN TEMP T PCD1 1C2 1C Ir TEMP PCB2 1C1 TE NN TEMP TCK opt OFF PCB2 1C2 TE mms TEMP CO K Voltage maa ei E PCBS IC2 TE MN TEMP 9 PCH3 ICI IE OEasy to view re
8. cording setting screen Free movement and extremely pnm Analog Wave Name Color Input Range Filter Alarm gt gt Scale Mod Dem po Span Up Spanlo Scale cull a D oO a d GE CH1 PCB1 JC1 TE TEMP TC K OFF OFF 1 2000 00000 200 00000 1 1 m E PCRA PCE ICI VO sov OFF or Q 25 00000 1 1 CH3 PCB1 WC2 TE gem TEMP e OFF JO 200 00000 1 1 IC TEMP En CH4 PCB1 W2 vo m OC sov 25 00000 1 1 EJ R i i A IC YOLI TA er TA OFF 00 200 00000 1 1 OFF OFF TEMP 25 00000 1 1 Free adjustment function mn Lk et OFF OFF 25 00000 1 1 Click on wave form scale or cursor and move 2 OU G T ksi OFF OFF P u down 25 0000 1 1 95 Sampling 200ms S 5 0sec 1Div Direct input selection V Warning d 18 57 29 Setting and editing can all be completed from this screen Operation base imager f ox cancel 4100 1150 14 hog 94 Change the position of the wave form with a single click of an icon re Display side by side Ko Display superimposed J ate 2007 07 20 17 12 Sampling 200ms S 5 0sec 1 Div os u Da a ig JA HER HKH SR r Ni V JA Extremely easy to use compared with conventional logger software _ 30 days trial software is provided A ility disk in a standard set Using the new special PC software Wave Inspire RX in a simple 3 step operation it is CT Ae m possible
9. el 49 7032 811 0 Fax 49 7032 811 199 Tel 86 21 5037 2222 Fax 86 21 5037 2200 specifications are subject to change without notice l l CSM ZR CA E 1 2 OMRON Industrial Automation Global www ia omron com Cat No E387 E1 Printed in Japan
10. lse and logic as well as temperature makes it practical in every field Pulse signal Logic signal input terminal input terminal Comfortable Usability Connection No need For Wiring Detachable terminal blocks no need for wiring to the main body The ZR RX40 has removable terminal blocks which means that it can be wired up securely in narrow places just by detaching the blocks Also if the terminal blocks are left in the location they have been wired into there is no need to rewire them back to the main body when you want take repeat measurements Optional parts needed Connection with just one screwdriver It uses M3 terminal blocks for analog signal input The ring terminals and tongue terminals can be easily connected with ei La just one screw driver There is no need for special tools so it can be used immediately rin terminal g KE tongue Geet No need for AC Adapter With optional batteries there is no need for the AC adapter When fully charged the ZR RX20 and ZR RX40 can run for 6 hours and 9 hours respectively In the unlikely even that the batteries should cut out there is no need to worry as the preceding data is saved with the data back up function ZR RX20 ZR RX40 Runs for Runs for 6 hours 9 hours lt 4 S 4 ZR XRB 1 Battery pack one ZR XRB 1 Battery pack two Configuration Measurement N
11. nels Each detachable terminal block has a standard 20 channels per unit Up to 10 units can be connected making it possible to extend up to as much as 200 channels It can also be used in car data logging where multi measurements of temperature voltage etc on many channels is needed Its seismic resistance corresponds to Class 1 A car parts JIS standards which means that it can be used stably even when there are vibrations and jolts during data gathering Base unit cable Length 60 cm Maximum 10 unit MAX connection 200CH Le C00b 12 07 CS J 10 34 04 4 CH GROUP gt yri MONITOR CH 1 lt TIMEDIV P gt Zom SS 2 8 1424 U 1 ALARM 111213 emm 290 Outstanding Versatility Portable size only 990 grams Its light weight of 990 gram makes handheld measurement possible It is guite portable and can easily be slipped into your brief case when setting out on a business trip Including 1 terminal unit block Not including battery or AC adapter Easy to see 5 7 inch color TFT LCD Comes with bright easy to see high intensity 5 7 inch TFT large scale color LCD panel Its wide field of vision means it can even be seen at an angle USB flash drive and internal 12MB flash memory Inside has a 12MB flash memory It is also possible to connect it to commercially sold USB flash drive which means that the recording capacity can be selected as reguired according to applica
12. o need for operation manuals Operates just like a mobile phone so you use it just by following your instincts rather than by following the manual Touching the NAVI button just once brings up a help screen so that you can operate it without the ponderous burden of browsing a manual Hu Navigation screen CH GROUP Sai Enable TIME DIV Disable ILE CURS DISI Description of the SPAN POSITION TRACE key Changes the span position and trace values in the Digital area Help Press NAVI to close the screen eae tte 1191 pridi tian minm inmi imin Operation Maintenance No need for time consuming work Easy display and easy editing with PC software Using the standard PC software provided graphs can be displayed on a PC or saved as Excel data Furthermore using the optional special PC software in addition to displaying graphs or saving Excel data it is possible to monitor multiple measurement data divided into groups so preparing data for reports is simple No need for initial set up with 3 way PC link 3 ways to link to a PC are available through a USB flash drive a USB connection or a LAN connection It is also possible to operate with wireless LAN with a commercially available wire LAN to wireless LAN adapter to support your application needs Orsio K UKOT HKS A E Carlee le Mol elikot M Calibrations and certification on request If a calibration certifi
13. stance Measurement Temperature Applied Measurement Multiwindow display ivicion di Temperature Range C Current Accuracy Wave All channel multi scale display Single window division display Display Scroll UP Down left riaht Y T X Y and meter display selectable Pt100 200 to 850 C FS 1050 C 1mA 1 0 C croll UP Down left right JPt100 200 to 500 C FS 700 C 1mA 0 8 C Setting Smart List view Tab form Pt1000 200 to 500 C FS 700 C 0 2mA 0 8 C Display Smart grouping Features under the following measurement parameters CSV A Operating environment 23 C 3 C Conversion Between cursors All data File batch conversions Left for at least 30 minutes after the power supply is turned on TI 1 1 4 i Sampling interval 1 s 20 ch Other Smart Search Cursor View Filter ON Average 10 times functions Cursor View Comment input GND connection Comment input Excel transfer Alarm mail Thermocouple used is T 0 32f other 0 65f Only ZR RX40 corresponds to the resistance temperature detector I F for Real time USB USB LAN logging OS Windows Vista XP 2000 Windows XP 2000 MModel Standard set Option Item Model Item Model Portable Multi Logger ZR RX20A E Battery Pack ZR XRB1 Portable Multi Logger ZR RX40A E Humidity Sensor ZR XRH1 DC Cable ZR XRD1 Base Set ZR RX40 Special option goods ZR XRE1 Extension Terminal Set ZR RX40 Special option goods ZR XRT1 Logic Alarm Cable ZR RX40 Special option goods ZR XRL
14. t ZR XRE1 0 1 1 1 Extension Terminal Set ZR XRT1 0 1 4 9 MStandard Specifications Main unit Model ZR RX20A ZR RX40A input merod allehannels Isolated Resistance ee non isolated Input terminal shape M3 screw type terminal Number of input channels 10CH Standard 20ch Max 200ch When the terminal unit is connected Sampling interval Max 100ms 100ms 10CH max A D resolution 16bit Measurement Voltage 20 50 100 200 500mV 1 2 5 10 20 50V 1 5V F S ranges Thermocouples K J E T R S B N W WRe5 26 m detector Uncorrespondence Pt100 JPt100 Pt1000 IEC751 Humidity 0 to100 Voltage OV to 1V Scaling conversion ZR XRH1 Refer to the option Logic 1CH Switch between logic4CH and pulse4CH Pulse 1CH Revolutions mode Counts mode Inst Mode switch method pulse type Revolutions mode Counts mode Inst Mode switch method Reference contact compensation Internal External switching Reference contact compensation accuracy 0 5 C 23 C 2 C when the input terminal temperature is balanced Maximum input Channel Terminals 60Vp p voltage Logic input Pulse 24V input Trigger input Input impedance 1MQ 5 Allowable signal source resistance Less than 3009 Alarm output Number of channels 1CH 4CH Output format Open collector output Output conditions Level judgment window judgment logic pattern judgment pulse judgment Trigger input 1CH PC I F Type USB 1 1 USB 2 0 LAN 10BASE T 100BASE TX
15. tion Do not use USB flash drive with security functions MPotential data recording time when 10 channels are used Recording interval sampling speed 200ms 500ms 1s 12MB embedded flash memory 13hours 1day 3hours 2days 21hours 5days 58days 256MB USB flash drive 12days 25days 62days 125days 1256days LAN port enabling remote control from web browser Equipped with LAN port for Ethernet connection By connecting the ZR RX 40 to a PC with a LAN cable it is possible to set the logger up with your web browser You can take measurements from your own desktop Remote control CE LAN cable tamman 10BASE T 100BASE TX Palm top Miniature light weight eee oe S ELE NNN S SR Ex 1 A Portable Multi logger Z R mu RY d 0 Not including battery AC adapter Input signal Voltage Humidity TB List of features Maximum All channels Thermocouples USB 3 5MB 10 channels isolated KJETRSBNWI flash drive finternal memory 3 5 inch Easy to 6 hour Display 16bit TFT LCD navigate menus battery switch resolution Easy to operate and easy to handle means that data can be gathered at ease even from eguipment jammed into narrow spaces Small but fully fledged multi function input of 10 insulated channels Even with its small size the 10 isolated channel input can provide accurate and stable measurements The ability to input voltage humidity pu