Home
Hyper Panel 288 User Manual
Contents
1. Avoid direct eye exposure to the LED output when it is on A A gt Safety Instructions www divinelighting com 1 Hyper Panel 288 v 1 e Make sure the power supply voltage is consistent with the requirements of this fixture eBefore the installation please ensure that the light s fasteners and mechanical structure have been received in good condition and there is no damage e This light is designed for indoor use only Ambient temperature should not exceed 40 degrees Celsius elThis fixture maybe mounted in any position provided there is adequate room for ventilation Make sure there are no inflammable and explosive items within 0 5 meters of any surface of this unit ePlease make sure that this fixture is properly grounded 3 Dimensions DIO D Lo Li on eh Eh ei Lei Lei Gi i G oro Ke ts da O LORO eh ki Ge oh KO da ch GHG 3 3 www divinelighting com 2 Hyper Panel 288 v 1 4 Product Features High quality LED e low power consumption brightness stable capability and long life Each color of LED dims in 256 increments May operate via DMX 512 Controller Master slave interconnected operating modes Functions Strobe color fades color snaps Uses switching power supply to protect the LED s DMX512 channels 9 channels 5 DMX Control Function Channel DMX Control Value Function 0 255 Red Dimming 0 100 0 255 Green Diming 0 100 0 255 Blue Dimming 0 100 0 255
2. Hyper Panel 288 User Manual CE RoHS SUMMae gege Saey MEDS UEC ONS pec cee eee iraniana Product DIMENSIONS cc cccecceesceeseeeeenseenseeseonseensenseonseeaseessoaseoasenssonseensoneees Produc E iatale DMX OD Gl ATION oerion ine SE E EO EEEE Display Operation Instruction 00 iii Ska TE dE ECH el d DEE ALA CONNECCION sorrire nenin anaE EENET ETE Wiring BE Te 1 PRO RO e A IO T OUDIESNOOUNO D Technical lieler e Tu en aR er ere 9 i 1 Summary Thank you for purchasing our products Please read these instructions carefully prior to operation Use the fixture according to these instructions to reduce the chance of damage and accident gt Product Introduction This led wash light is designed in ultra thin form It uses high brightness R G B A and W LED with color mixing ability Each color can be independently dimmed It utilizes a switching power supply making it low in weight and power consumption The built in programs include dimmer strobe gradual change fading and more It may be controlled remotely by DMX 512 signal gt Packing list Hyper Panel 288 1PC Bracket 1PC Plastic screws 2PCS DMX cable 1PC User manual Warranty Card 2 Safety Information gt Safety Notes gt Repairs should be attempted only by qualified professionals gt Always make sure disconnect from the power source before setting up servicing and moving gt
3. Dip switch 1 10 in the position ON others are OFF 1 DMX 512 signal receive Dip switch 10 in the position ONT DMX address will be determined by adding the numbers below the switches set to ON In the figure below switches 2 and 4 are on therefore the DMX address is 2 8 10 The www divinelighting com 4 Hyper Panel 288 v 1 DMX controller not included should be configured to the same start address J0 0000n f wl Ji l a a l ON 1 2 34 56 7 8 9 10 10 Dip switch 1 2 4 8 16 32 64128 256 DMX ON OFF In the example below switches 4 and 5 are set on Therefore the DMX address is 8 16 24 1090 0010 f S kKGGCEh ON 12 34 56 7 8 9 10 10 Dip switch 12 4 8 16 32 64128 256 DMX ON OFF 8 Master Slave Operation Units may be set in a master slave orientation so that all of the slaves will have the same operation of the master First daisychain all of the units together using XLR cable The first unit of the chain will be the master and the rest will be slaves Master Units are always set in Master mode i e outputting DMX signal that mirrors their own operation unless they are set in DMX mode Switch 10 set ON Signal lines longer than 60 meters or 20 fixtures should utilize a signal amplifier Slave For each slave unit set Switches 10 and 1 in the position of ON Note This product uses input and output power cord 0 75 m m copper core wire that allows the units to be powered together Whe
4. oc III Any DMX controler www divinelighting com 7 Hyper Panel 288 v 1 11 Troubleshooting Possible Solution Cause Ensure the power plug is fully inserted Can not turn on the Ensure the power switch for the lights is on light Check the fuse continuity Check the DMX cable is connect to the lights DMX not functioning Check the DMX512 controller for signal output Check if the lights is in DMX mode Switch 10 to ON When connect to the electricity did the led flash one time If so the power source is normal If not olease check if the switch and Display not bright the transformer has power out Check if the power input of the IC board is normal Check if the cable connect to the display loose Change the main board to see if it is normal Change the display When connect to the electricity did the led flash one time If so the power source is normal If not please check if the switch and LED s not coming on the transformer has power out Check if the power input of the IC board is normal Check if the cable connect to the display loose Change the main board to see if it is normal Change the display LED is connect in series first then in parallel Check to see if any LED s are loose Use the multimeter to check if the led is powered or not If not www divinelighting com 8 Hyper Panel 288 v 1 some of the LED s please change the led not coming on Check whether current limitin
5. Amber Dimming 0 100 0 255 White Dimming 0 100 VV WM WM V V V 0 255 Master Dimmer When the 7CH is between 250 255 Speed of Macros this channel adjusts the Macro speed Not used 10 249 24 colors combinations CH1 CHb5 is inactive 250 255 Color jumping change CH6 adjusts speed O 16 255 Gradual change O esch Ol OQ DMX IN DMX OUT DIP Switches POWERIN POWER OUT 2 7 Fixture Operation When Switch 10 is set to ON the unit is in DMX mode and switches 1 9 determine the DMX address When Switch 10 is set to OFF the unit runs off built in programs which are determined by the setting of Switches 1 9 Unit will send DMX signal mimicking it s actions for any Slave units you wish to attach Jaaa A Gal Ga Ga Lal lalla lalla ll Von 1 2 3 4 5 6 7 8 9 10 10 dip switch 12 4 8 16 32 64128 256 DMX ON OFF Built in Programs Activate by turning switch 10 to OFF unit will send DMX signal as master Turn Switch 1 on to activate red diodes turn Switch 2 on to activate green diodes turn Switch 3 on to activate blue diodes Switches 4 6 are used to activate the strobing function Dip switch 9 10 should be off sound Active Mode Single Fixture Dip switch 9 in the position ON 10 in the position OFF LED s will change color to sound Master Slave Setup for Sound Active Action Master Dip switch 9 in the position ON others set to OFF slave
6. g resistor is normal or not Check constant current IC is normal or not compared with the normal IC single color LED s Check the switch of this color is normal or not Always bright not Change the IC control board bright 12 Technical Specification Input voltage AC 95 260 50 60HZ Power Consumption 22W Lamp Type High Power LED 10 mm Lamp Spec R 56PCS G 56PCS B 56PCS A 60PCS W 60PCS Control Signal DMX512 Master Slave Control mode stand alone DMX master and slave Number of Channels 9CH Color effect R G B A W mixing Built in Effects dimmer strobe snap and gradual change Beam Angle 25 Cooling mode Natural Convection Protection Rating IP20 Anti electricity intension 1 5KV Insulation Resistance gt 2 MQ Size 365 245 80mm Net Weight 3 2KG www divinelighting com 9 Hyper Panel 288 v 1
7. n using 220V AC link no more than 35 units together Using 115V AC link no more than 20 lights 9 XLR Cable Connections gt XLR cable gt XLR DMX connections are connected male to female as shown below gt pin 1 ground pin 2 negative signal pin 3 positive signal www divinelighting com 5 Hyper Panel 288 v 1 ee eee eee eee eee eee en ee ee XLR Male Socket 1 Grou CR XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Css SSS SSS ee Lens a mm 3 Hot Pin 3 Data True positive COMMON DMX512 OUT DMX512 IN 3 PIN XLR 3 PIN XLR Note In order to avoid failures and interference with signal transmission use a terminator plug Between pins 2 and 3 connect a resistance1200 1 4W atthe end of the DMX connecting as below Termination reduces signal errors and avoids signal transmission problems and interference lt is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture gt Conversion between 3 pin and 5 pin XLR gt If the output cable of DMX 512 controller is the 5 PIN please use a 5 PIN to 3 PIN adapter www divinelighting com 6 Hyper Panel 288 v 1 3 Pin XLR to 5 Pin XLR Conversion 3 Pin XLR Female Out 5 Pin XLR Male In Data True signal Do Not Use Not Used Do Not Use 10 Connecting Diagram gt Fixture connecting picture DMX512 In Power In ooo oo
Download Pdf Manuals
Related Search
Related Contents
SERVICE MANUAL 6320910 Service Manual MADAS® - Combustion Control Copyright © All rights reserved.
Failed to retrieve file