1. 1 The control unit is installed with the unlocked password The user can enter his own password e g 1234 From this moment the important parameters cannot be altered without the password being unlocked that is resetting the password 1234 After changing essential parameters the user can leave the control unit unlocked set any new password or enter 9999 which activates the password 1234 2 Producer gives the control unit with the set password The user cannot alter the important parameters The servic can change the settings with its own secret password At the end a serviceman enter the secret password or 9999 the user still hasn t access to the important parameters 3 Producer gives the control unit with the set password The user cannot alter the important parameters The servic can change the settings with its own secret password At the end a serviceman leaves the control unit unlocked the user now has access to the important parameters He can enter his own password like in example No 1 4 Producer gives the control unit with the set password The user cannot alter the important parameters The servic can change the settings with its own secret password At the end a serviceman sets the password e g 1234 and tells it to the user the user has access to the important parameters but without knowing the password the other persons cannot make the changes 5 The user has the unlocked control unit
2. By clicking the CONFIRM OK button 5 one confirms the changes the parameter field stops blinking The changed parameter not confirmed for 10 secs is not accepted by the control unit and it recalls a previous value of the parameter 3 1 Screens The alarm screen is not seen till the following emergency situation takes place 1 Damage of sensor T1 T Firep shows up 2 Damage of internal temperature sensor of reference temperature Ref Temp shows up 3 Exceeding CO concentration by shorting the terminal X1 Gas shows up 4 The exceeding of the acceptable maximum temperature of the fireplace T MAX shows up The alarm situation is accompanied by the status diode 7 blinking and a broken sound alarm that can be turned off by pressing any button The screen of the control unit status displays the preset fireplace power and the phase of the control unit operation lt _ Fireplace power 1 2 3 F1 Phase of the optimizer operation The fireplace power is set by pressing the Wbutton 4 On the display it corresponds to 1 2 or 3 Pressing the START button 2 opens up the air damper and the cycle start The screen of the control unit operation displays the current temperature of the fireplace opening level of the air damper phase of the control unit operation and possibly a combustion error lt Combustion temperature T1 or the blinking text END 1200 The refuelling of the fuel i
3. CHOOSE Fig 2 View of control panel Text display Button to increase the value A or START Button to choose the parameter Button to lower the value W or STOP Button to confirm the changes OK or AUTO Button to enable the manual mode W MAN Status diode of the control unit alarm red standby green Diode of the combustion cycle green Diode of the air damper operation blinking means the overload of the drive 22 OSS i a a 4 WANA PRODUCENT ZASILACZY SIECIOWYCH ISO 9001 2000 CE CONFORMITY DECLARATION Ref No 58 RT 01 2007 1 B We ZAKLAD ELEKTRONICZNY TATAREK Jerzy Tatarek 75 Swieradowska St 50 559 Wroclaw declare under our sole responsibility that the following control unit FIREPLACE POWER OPTIMIZER model RT 080M is in conformity with the basic requirements included in Directive EMC 2004 108 WE of 15 12 2004 the electromagnetic compatibility law of 13 04 07 and Directive LVD 2006 95 WE of 21 08 07 Laws Journal of 2007 No 155 pos 1098 regarding the requirements for electric devices To the conformity evaluation the following harmonized standards were used PN EN 60730 2 1 2002 Automatic electric control units for house usage and the like Part 2 1 Specific requirements regarding electric control units for electric house devices Automatic electric control units for house usage and the like Part 1 General requirements PN EN 60730 1 2002 PN EN 55022 2
4. of water in the cap Because of high temperature maintaining close to the water cap and coming from that both a risk of damaging the sensor and false measurements of temperature its assembly should be carried out on the pipe channelling water from the water cap beyond the fireplace gt W zZ I oO Fig l Basic operation scheme of the optimizer Tl Temperature sensor of the combustion D1 Sensor of opening the furnace door option PP Controlled air damper 2 1 Operation phases of the control unit The optimizer controls the combustion process as a cycle of the following phases 1 F0 STOP Standby phase The control unit awaits opening the door and preparing the fuel for the next heating FO is a temporary state to STOP In the STOP state the air damper is closed 2 F1 Start phase After loading the fuel and its lighting you close the furnace door It s a signal for the control unit that the combustion cycle has begun The air damper is fully open 3 F2 Heating up phase After reaching the limit temperature and warming up the fireplace the pass to the phase F3 follows 4 F3 Burning combustion phase Stabilization of combustion temperature depending on the chosen power of the fireplace F4 Phase of decreasing temperature The air damper is again gradually closed F5 Embers phase Signalling the demand for replenishing the fuel 6 F6 Phase of removing the furnace gases The air damper first opens up and then closes a
5. or his own password Serviceman decides the user though oughtn t have access to the important parameters The serviceman locks the control unit with his secret password which removes the user s password and locks the control unit 6 Serviceman doesn t have to know the user s password Always he can use his own secret password and at the end lock with the 9999 which reactivates the user s password
6. 000 Electromagnetic compatibility EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement methods Complementary information Laboratory ASE 51 618 Wroclaw 1 Wystawowa st Test report No 39 DL I 07 of 22 06 2007 41 DL 1 07 of 03 07 2007 Electronic Engineering Plant TATAREK has initiated management system and complies with the following standard 1SO9001 2000 CERTIFICATE No 133 2004 of 01 2004 Polish Foreign Trade Chamber The last two digits of the year in which the CE marking was affixed 07 Place of issue Manufacturer representative Wroclaw Miros aw Zasepa Mase nm Date of issue Position 08 2007 Konstruktor WARRANTY 1 Warranty is valid 24 months from the date of sale 2 Producer does not take responsibility for any mechanical damages made by user 3 MAKING REPAIRS OR MODYFYING THE DEVICE BY USER IS FORBIDDEN AND CAUSES WARRANTY CANCELATION 4 Warranty card is valid only with date of sale seller s signature and stamp 5 Warranty and after warranty repairs should be done only by producer damaged regulators should be sent to producer in order to make all repairs needed 6 Warranty protection includes the EU 7 Warranty does not exclude not restrict and not suspend buyer s rights coming from the incompatibility of the article with the agreement Laws Journal No 141 Pos 1176 WARNING ANY MODIFICATION OF THE CONTROL UNIT MADE BY A USER CAN BE THE CAUSE OF SAFETY CONDITIONS D
7. AT THE UNLOCKED PASSWORD NAME RANGE DEFAULT FUNCTION The serial number of the control unit The parameters set of the control unit Currently there s available 1 set the standard one The serial number can be changed only at the unlocked password NoProd Standard Standard RESET Setting the value to ON causes the recall of all parameters to OFF ON OFF their default pre sets and restarts the control unit The reset can be performed only at the unlocked password 0000 PASSWORD OFF PASSWORD ON After entering the wrong password the restart follows PASSWORD 0 9999 Password The changes of important parameters are possible only at the unlocked password To unlock the password you need to input proper sequence of digits with the buttons A W With the button to change the digits position and OK button 6 to acknowledge all and finish the procedure of changing the password The unlocked password is set to 0000 Once again entering into the password change procedure causes a new password to be set s PASSWORD 9999 HAS CONSIDERABLE MEANING IT CAUSES THE REACTIVATION OF THE PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING EXPOSED PASSWORD OF PRODUCER S SERVICE IS UNIQUE AND IS NOT DEPENDENT ON THE USER S PASSWORD IT SHOUDN T BE EXPOSED TO THE USER INSTEAD OF THAT THE SERVICE CAN SET TO THE USER HIS OWN PASSWORD Examples of passwords
8. ETERIORATION AND CAN EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES SUPPLIED Connection cable of the control may be replaced only by producer or his authorized service locations WARNING 1 Producer does not take the responsibility for damage caused by atmospheric discharge 2 and overvoltage in the mains 3 Burnt fuses are not subject to warranty replacement Date of sale Seller s signature and stamp ARGO FILM Recycling Plant No 6 180 Krakowska st 52 015 Wroclaw Register No GIOS E 0002240WZ Worn out electronic the utilization collection place where will 0 515 122 142 be accepted for free and electric devices must be transfered to Ph 071 794 43 01 yd a TNS a Zaktad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 tax index number 899 020 21 48 Bank account BZ WBK S A O WROCLAW 6910901522 0000 0000 5201 9335 www tatarek com pl E mail tatarek tatarek com pl The operation state is presented on the text display 1 The screens inform about the operation of devices temperature of the furnace they make it possible to change the parameters etc The change of screen is done by pressing the CHOOSE button 9 3 If this is the screen that is able to change a parameter press the CONFIRM button 5 OK which causes blinking of the parameter field to be changed By pressing 2 or V 4 one can alter its value
9. INAS Zak ad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 Tax index number 899 020 21 48 Bank account BZ WBK S A WROCLAW 6910901522 0000 0000 5201 9335 www tatarek com pl E mail tatarek tatarek com pl 6 TANINI RT080M 2012 v 1 0 ANG Zak ad elektroniczny TATAREK Jerzy Tatarek USER MANUAL v 1 0 21 02 2011 software 1v0 FIREPLACE OM FIREPLACE POWER OPTIMIZER RT 080M 1 Basic technical parameters Power 230V 50Hz Auxiliary power Rechargeable battery 4 8V 60mAh Power consumption without load SW Max connection power 250W Operation conditions 0 40 C humidity 10 90 no condensation Housing protection class IP41 Fuse 6 3A 250V 1 contact NO and NC normally closed and open contact Number of nonvoltage control outputs Number of outputs to control the air damper drive 1 5V 500mA DC Number of temperature sensors 1 Thermocouple type K 0 1300 C Temperature measurement precision 5 C Temperature measurement resolution 1 C 2 Principle of operation The RT 080M control unit is used to control the combustion process and maintaining the embers phase as longas possible by controlling the air damper that channels air to the combustion chamber Thanks to lowering the combustion curve during the phase of temperature increase and its raising during the phase of temperature decrease the control unit exte
10. Restar 10 1250 C 45 C Restart temperature after switching on If after switching on the control unit the temperature in the furnace is higher than T Restar then automatic start follows Ti STOP 0 600secs 120secs After this time the transition to the standby phase STOP takes place if the temperature T Restar is not reached T F2 50 1250 C 400 C End temperature of the heating up phase T F3 1 50 1250 C 250 C Temperature of the phase F3 at power 1 T F3 2 50 1250 C 300 C Temperature of the phase F3 at power 2 T F3 3 50 1250 C 350 C Temperature of the phase F3 at power 3 dT F3 10 200 C 50 C Maximum temperature increase in the phase F3 dT F3 F4 10 300 C 30 C Temperature drop in relation to F3 starting the phase F4 Ti F4 1 10 mins 2 mins Time span of the condition DT F3 F4 required for finishing F3 and going to F4 T F5 50 1250 C 150 C Start temperature of the phase F5 Ti F5 1 60 mins 5 mins Period of the phase F5 Ti PDM 0 10 mins 1 mins Period of the phase F6 Scavenge time Opening the air damper and burning out furnace gas Phi F3 1 0 100 60 Maximum opening of the air damper of the phase F3 at power 1 Phi F3 2 0 100 65 Maximum opening of the air damper of the phase F at power 2 Phi F3 3 0 100 70 Maximum opening of the air damper of the phase F3 at power 3 Plo F3 1 0 100 10 Minimal opening of the air damper of the phase F3 at power 1 Plo F3 2 0 100 10 Minimal opening
11. as higher potential it s important for Open Collector Systems Schort circuit of the contacts means the exceeding of permitted CO concentration At the lack of CO control you leave the contacts not connected Sensor of opening the furnace door At the closed door the terminal D1 should be opened see Fig At the opened door the terminal D1 should be short circuited Sensor of combustion temperature Thermocouple type K the wire of higher potential is green of lower one is white 4 Mounting the RT 080m control unit THE CONTROL UNIT IS SUPPLIED WITH 230V 50HZ ANY MOVES REGARDING THE INSTALLATION SHOULD BE MADE AT THE DISCONNECTED MAINS THE CONTROL UNIT HAS TO BE CONNECTED TO THE MAINS WITH THE ZERO PIN CABLE THROUGH THE DIFFERENTIAL DEVICE THAT CUTS OFF THE POWER ACCORDING TO THE REGULATIONS THE PRODUCER DOESN T TAKE ANY RESPONSIBILITY FOR BOTH DAMAGES CAUSED BY WRONG USAGE OR FAULTY MOUNTING OF THE CONTROL UNIT AND ITS USAGE NOT IN ACCORDANCE WITH ITS PURPOSE 10 PARAMETRS OF LEVEL 1 NAME RANGE DEFAULT SETTING FUNCTION Signal OFF ON ON Switch on Switch off of the sound alarms PARAMETERS OF LEVEL 2 THE PARAMETERS CAN BE ALTERED AT THE UNLOCKED PASSWORD NAME RANGE DEFAULT SETTING FUNCTION DelayTim 15 600secs 60secs Delay of the control unit start period of the phase F1 T
12. nd there s the pass to the standby phase m 2 2 Power of the fireplace The user himself decides about the heating power of the fireplace There re 3 power levels 1 minimum 2 3 max with which the corresponding parameters of the burning phase F3 are connected 2 3 Air damper The air damper regulates air inflow to the combustion chamber dependent on the phase During the flap move of the air damper the diode 9 lights The blinking means a temporary overload of the drive affected by met resistances 2 4 Additional functions of the control unit The main function of the RT 080m control unit is optimizing the combustion process via the control of air inflow into the combustion chamber realized through the air damper Additionally lAn external device controlling CO concentration can be connected to the control unit In case of detecting the danger the air damper PP opens up improving the ventilation ofroom additionally the signal alarm switches on The control unit switches on the ALARM output in case of damage of the temperature sensor of the furnace T1 or exceeding of CO concentration 3 Operating the control unit On the control panel Fig 2 are the control elements of the control unit In the standby state the green control diode 7 of the standby state lights Turning on the control unit occurs after opening the furnace door The closing of the door starts the combustion cycle which is indicated by the green diode 8
13. nds the combustion process The most important advantage of this model of the optimizer is the capability to choose one of 3 programs for operation power of the input depending on the user s needs and maintaining as long as possible the chosen range of the operation Thanks to that it s possible to achieve out of a given portion of fuel an optimal portion of energy which allows to raise functionality economy of the fireplace or stove to which the RT 080m control unit has been applied The operation of the RT 080m optimizer control unit begins at the moment that the furnace door closes the sensor of opening the door D1 or in case of no sensor with the START button on the front control panel The combustion process starts controlled by the furnace gas temperature sensor that manages the air damper which supplies air to the furnace At the time of a systematic decrease of temperature burning out the input the air damper is being closed When the embers phase in the furnace is reached the air supply is cut off interrupted by scavenges in order to get rid of waste gas from the combustion chamber In alarm situations also power declines the air damper is opened that enables the full burnout of the fuel input The special input to cooperate with an external CO detection sensor improves the safety of using the fireplace The control unit is equipped with its own emergency power supply The pause in power supply up to 8secs doesn t affect the control unit
14. ng the cycle Before opening the door the air damper should also be opened by pressing START 2 or passing to the MAN mode After lighting the fuel and closing the door you must again press START 2 or AUTO 5 ifthe control unit is in the manual mode MAN In the MAN mode you must not close the air damper completely before reaching the embers phase because there can be a dangerously increased concentration of CO poisonous carbon monoxide The screen of setting the parameters Menu 0 Normally the level of parameter setting Menu equals to 0 which means the parameters aren t available After changing the level Menu to 1 2 or 3 the successive screens show the values of parameters The last screen contains after which it comes back to the above mentioned screens I THEPARAMETERS ADAPT THE CONTROL UNIT TO THE PROPERTIES OF THE FIREPLACE THEIR CHANGE SHOULD BE CONSULTED WITH THE PRODUCER OF THE FIREPLACE INCAUTIOUS CHANGES CAN CAUSE UNSTABLE AND INEFFICIENT OPERATION OF THE SYSTEM CHIMNEY FIREPLACE PP PP Air damper vege STER YELLOW BLUE a GND tack e n Door sensor ALARM WHITE y GREEN x3 T1 Alarm CO L MAINS i 230V 50Hz Fig 3A Wiring scheme PP X3 D1 T1 Electronically controlled air damper Input to connect a control device of CO concentration The input h
15. of the air damper of the phase F3 at power 2 Plo F3 3 0 100 10 Minimal opening of the air damper of the phase F3 at power 3 P F5 0 100 5 Opening level of the air damper at the start of F5 TypChoke Vind 2 Control type of the air damper 1 Continuous control servomotor of the air damper always active 2 Dynamic control servomotor of the air damper active only if a position change of the air damper is needed PARAMETERS OF LEVEL 3 PARAMETERS CAN BE CHANGED ONLY AT THE UNLOCKED PASSWORD NAME RANGE DEFAULT FUNCTION Manual OFF ON ON Switching ON OFF the manual mode Manual that is switching off automatics The controlling of the air damper opening from the keyboard Demonstration change of the Manual parameter Parameters level 3 Press repeatedly button 9 3 till the Menu parameter setting screen appears OK button 5 gt 0 starts blinking threefold button 2 gt 3 blinks OK button 5 gt 3 stops blinking Parameters level 3 was chosen repeatedly D 3 gt Manual shows up actual value OK button 5 gt actual value to be changed begins blinking A V gt setting a new value OK button 5 gt confirming the new value repeatedly 49 3 button till the parameter end setting screen appears PARAMETERS OF LEVEL 4 PARAMETERS CAN BE CHANGED ONLY
16. operation because during that time the buffer power supply switches on e g A200WAC TATAREK If the pause is longer the air damper opens up in emergency before the optimizer control unit switches off Advantages of the combustion optimizer limiting the maximum combustion temperature capability of choosing optimal fireplace power for the user extending the combustion process decreasing fuel consumption extending the exploitation time of fireplace inputs shutting off air supply after ending the combustion preventing the furnace cool off cooperation with CO sensors opening up the fresh airing of the combustion chamber in emergency 2 Admission date Realization date Signature Remarks WARNING WE INFORM THAT THE OFFERED CONTROL UNIT CAN BE ONLY APPLIED TO THE FITTING DEVICES THE REQUIREMENTS OF THE TECHNICAL AND BUILDING STANDARDS CONCERNING THE CORRECTNESS OF STOVE FITTER AND HEATING SYSTEMS HANDLING THE FIREPLACE INPUTS MUST BE MET WRONG USAGE OF THE CONTROL UNIT CAN LEAD BOTH TO ITS DAMAGE AND IN EXTREME CASES TO THE DAMAGE OF THE FIREPLACE INPUT AND HEATING SYSTEM CONTROLLED BY THE FIREPLACE AS WELL ALONG WITH THE DEVICES THAT COOPERATE WITH THE HEATING SYSTEM CAUTION We inform that in case of systems based on the water cap you should pay attention to the location of mounting the temperature sensor
17. s required F1 50 e _ Opening level of the air damper Phase of the optimizer operation 5 Reaching the embers phase F7 is accompanied by a broken sound signal switch off with the button 6 text FuelOUT and blinking of the green diode 8 which indicates the need for replenishing the fuel in case of continuing the burning Thecontrol unit can run in the automatic or manual mode The longer pressing MAN 4 6 about 2secs causes the pass to the manual mode That s signalled by blinking status diode 7 The air damper opens 100 From now on you can manually control the air damper W 4 causes the shutting one step 10 and 2 the opening The comeback to the automatic mode occurs after pressing AUTO 5 The transition to the manual mode MAN can be blocked if the parameter of level 3 Manual is set to WY In the automatic mode each opening of the door causes the air damper to be set at 100 and each shutting ofthe door causes the combustion process started and the diode 8 lights Ifthe furnace is cold then after the time DelayTim Ti STOP see parameters of level 2 the control unit closes the air damper and passes to the standby state Likewise the control unit acts when the power is switched on During the operation without the sensor of opening the door the panel buttons are used for controlling Pressing START 2 causes opening the air damper and starti