1. Consumption Design Test and Hush Button Low Battery Warning MCU Processing Resist False Alarm Efficiently SMT Manufacture Technology Good Stability INSTALLATION NOTICE 1 Install the detector where the water is likely to leak 2 Do not locate the detector in cabinet and other places where the alarm sound can not came out easily 3 Do not install it at the area with rain oil smoke and steam of cooking range 4 Do not install the detector with submersed water INSTALLATION STEPS 1 Attach the mounting bracket on the wall or board firmly with screws 2 Mount the rest of the detector into the bracket 3 Put the probe in the floor where the water is likely to leak Or use the sensor magnetic adsorption where required detects water 4 Connect the alarm to the power OPERATING PRINCIPLE 1 Insert 2pcs 1 5V AA batteries into the battery cabinet independent or wireless type Connect DC9 24V power to 5 pin connector network type While the connected DC power or battery voltage is more than 2 4V the green LED flashes once with buzzer sounding While the voltage is less than 2 4V the yellow LED flashes rapidly for 3 times with buzzer sounding Then the detector comes into normal working status 2 The green LED long lighting under DC power supply While the operated with batteries the green LED flashes once every 25 seconds to indicate the normal power supply 3 Routinely long press the TEST HUSH button gt 2
2. On alarming and mute status it will cancel mute after long or short pressed the button The battery voltage will be down during usage process When the battery voltage lt 2 4V the detector will give out low battery signal The yellow LED flashes once every 50 seconds with the buzzer sounding 9 The detector will stop alarm automatically and reset to normal working status after the leakage handled properly INDICATIONS SUMMARY The battery gt 2 4V or DC power supply The battery lt 2 4V power supply Indication Green LED flashes once with buzzer sounding Yellow LED flashes rapidly fo 3 times with buzzer sounding Green LED flashes constantly Normal DC power supply Green LED flashes every 25s Normal battery power supply Red and green LED flashes alternately with buzzer sounding every 3 sounds paused Testing state release the button to exit Red LED flashes with buzzer Alarming state detects water sounding every 3 sounds paused or touch conductive objects Red and green LED flashes alternately once every second without buzzer sounding Alarming mute state long short press TEST HUSH button to cancel mute state Normal mute state short press TEST HUSH button to cancel mute state Green LED flashes once every second without buzzer sounding Low battery warning the voltage lt 2 4V the battery should be replaced Yellow LED flashes once every 50s with the buzzer sounding M051CVe
3. USER MANUAL OF WATER LEAKAGE DETECTOR PRODUCT INTRODUCTION This product is a water leakage detector using the principle of electrode immersed resistor changes to detect water The detector adopts MCU intelligent detection rust proof metal probe design with advantages of high accuracy and sensitivity low power consumption long term stability and reliability etc It can be widely used in all water storage equipment such as basement water tank machine room water route water tower water cellar pools water room solar energy and anywhere to detect water leakage area Three optional models Independent Network Wireless PRODUCT PROFILE iz ee La S LED TEST Button Sensor Built in magnet has adsorbed function 5 PIN connector instruction Network type only TECHNICAL SPECIFICATION DC3V 2x1 5V AA Alkaline Batteries e indicator Red DC Power anode Black DC Power cathode White COM relay Orange N O relay Yellow N C relay Operating voltage DC9 24V Red LED and buzzer sounding Faultindicator indicator Yellow LED 0 60 C 0 80 RH no congelation 85dB 3M Working Temp Temp Sound level Hush time 10 minutes wall mounted or board installed 89 89 28mm bracket not included Alarm output 3 1 5MHz 433MHz Relay 2262 or 1527 NC NO M051CVer1 0 FEATURES Rust proof Metal Probe Long Service Life Sound and Flash Alarm Low Power
4. r1 0 EMERGENCY ALARM TREATMENTS Treatments for water leakage alarm 1 Shut of water valves 2 Drain away the water and overhaul the tubes to reduce the economic losses and water wastes caused by leakage water NOTES 1 When the sensor detects water leakage and the detector still sit on alarming state after drain away the water It may the water residue of probe inside or surface Dry the water residue on surface with towel to check whether the detector recovers to normal working status If still on alarming state take the sensor off and shake the residue water out dry the surface with towel and installing then 2 Replace the battery timely on low battery warning to ensure the detector works properly 3 Do not store any other subjects on the surface of detector as this may effect the indication and sounding 4 Test the detector routinely to ensure proper operation Clean the surface with soft towel regularly 5 Read carefully and install correctly as required in this manual In case the product is failure do NOT try to fix it by yourself Contact with your dealer for replacement
5. seconds for testing to make sure the detector works properly The red amp green LED flashes alternately after 2 seconds with buzzer sounding every 3 sounds paused until release the button Moreover the relay works network type and send out wireless alarm signal wireless type on testing 4 Once the sensor detects leakage water the red LED flashes rapidly with buzzer sounding every 3 sounds paused to warn the users Moreover the relay works and output alarm signal network type it will send out wireless alarm signal wireless type on alarming USER MANUAL OF WATER LEAKAGE DETECTOR During alarming status long or short press the TEST HUSH button to enters into mute status The red amp green LED flashes alternately once every 1 second the buzzer stop sounding relay or RF model shut off The mute status will end automatically in 10 minutes later If still detects leakage after 10 minutes the detector will alarm again to warn users 6 Short press the TEST HUSH button on normal state to enter into mute status The buzzer sounds Di once and green LED flashes every 1 second While has leakage water the red amp green LED flashes alternately once every 1 second but without any alarm signal such as sound relay or RF Users can mop floor or wash pool on mute status Re press TEST HUSH button to end up the mute status 7 Under alarming status no matter long or short press the button it will goes into mute status