1. guide for more information You have a new GPS when the GPS LED on the terminal is solid green b Press and hold the audio button for 3 seconds to register the terminal The terminal is registered once the GPS light goes out completely c When you try making a call the third LED from the right should start to flash The data connection is established when the signal strength light goes solid Green If it goes red it has failed Now refer to ACCESS Portable configuration below ACCESS Portable configuration No changes to the default Ethernet settings on the ACCESS Portable are required Be sure that the ACCESS is set for DHCP network addressing Page 6 6 5 Start your broadcast using ACCESS Select the Remotes menu and then Manage Connections from the drop down menu to display the Select Remote ACCESS Unit menu This menu allows you to select from a number of pre configured connections and simply press the green Connect button to initiate the transmission of audio Network Remotes Stats Configure Select Remote ACCESS Unit ra Loophack hot connected Be Comrex Lab Voice not connected Comrex Lab Music not connected If a connection has not been pre configured for your receiving Studio unit simply select Add New Remote from the Remotes drop down menu The screen below displays allowing you to enter the information necessary to connect to the Studio unit Please consult your ACCESS user s manual for a more
2. N O 0 A N N N Milscecccses beecseene ara Busaser seesceess ocogocopa 1 Overview Comrex ACCESS Stereo BRIC IP codecs offer high quality audio transmission over a wide variety of wired and wireless IP circuits Available in both Portable and Rackmount configurations ACCESS provides fully bi directional mono stereo and dual mono audio transmission with up to 20 kHz frequency response Used with Inmarsat s BGAN service ACCESS allows users to transmit broadcast quality audio from virtually any location on the planet 2 Product range BGAN terminals can be used with either the ACCESS Portable or the ACCESS Rackmount The ACCESS Portable with integral user interface and battery power is preferred for use with portable BGAN terminals 3 Typical users Comrex ACCESS is in use around the world by radio broadcasters and governmental agencies in a variety of applications ranging from outside broadcast of news entertainment and sporting events station to transmitter links as well as surveillance and closed circuit audio communications a Key Features Comrex ACCESS codecs offer the following main features over the BGAN network e 20 Hz to 15 kHz frequency response fully bidirectional audio using Inmarsat s 32Kbps streaming service e Built in audio mixer interface with microphone preamp w 12V phantom power headphone output line level input output volume controls e ACCESS Portable comfortably fits in the palm
3. detailed description of these functions Network Remotes Stats Configure Add Hew Remote Mame Studio Profile Hat Deft iw Default Backup Remote No backup C Using Comrex ACCESS over BGAN Page 7 6 6 Equipment needed e ACCESS Portable or ACCESS Rackmount Codec e BGAN terminal e Laptop computer with web browser e Multiport Ethernet switch e ACCESS Rackmount connected to the public Internet studio side 7 BGAN customisation No BGAN customization is required 8 Hints and tips The following are best practice hints and tips to ensure you get the most from ACCESS over BGAN e The BRIC HQ2 algorithms that come standard with ACCESS provide broadcast quality mono and stereo transmission when used with BGAN 32 kbps Streaming service 9 Technical summary Feature Data connections Audio input connections Audio output connections Power connections Display options Using Comrex ACCESS over BGAN ACCESS rack mount RJ 45 RJ 11 PSTN USB Serial 9 pin GPI 9 pin Stereo balanced line level XLR AES3 XLR Stereo balanced XLR AES3 XLR IEC style internal 110 220V auto switching Via web browser to integrated web server VGA adapter on rear panel ACCESS portable RJ 45 CardBus slot USB Serial DIN GPI DIN Mono balanced adjustable mic line XLR unbalanced stereo line level 1 8 3mm unbalanced hands free mobile 1 8 8mm Unbalanced stereo adjustable hea
4. of your hand and includes rechargeable LION battery good for seven hours of talk time e Optional clip on mixer provides an addition five mic inputs and headphone outputs e Optional HE AAC algorithms provide up to 20 kHz audio using Inmarsat s 64Kbps streaming service Using Comrex ACCESS over BGAN Page 1 6 1 Benefits to BGAN users Comrex ACCESS provides e Completely wireless transmission from virtually anywhere on Earth e A small compact handheld unit less than 6 Ibs 3 kg e 15 kHz mono and stereo transmission using 32 kbps Streaming e Ability to be pre configured for Plug amp Play operation Setting up This section describes how to set up BGAN for use with Comrex ACCESS and gives an example of a typical configuration when using ACCESS with a BGAN terminal Broadcast transmission was tested over a standard 32 kbps Streaming connection using an EXPLORER 500 The audio broadcast was transmitted to a terrestrial Internet address The test showed that BGAN terminals and the Inmarsat BGAN network work well as a transport media for the Comrex ACCESS IP Codec The test has also been carried out with the EXPLORER 110 and the Hughes 9201 it is assumed to work as well with the EXPLORER 300 EXPLORER 527 and EXPLORER 700 192 168 0 10 lnrmrar sae BGAN 192 168 0 1 EXPLORER ACCESS IP Codec in Router Mode 32 Kbps Streaming PO with web browser The ACCESS Portable computer
5. the Internet If you have a Nera World Set the display shows Connected Now go to ACCESS Portable configuration on page 6 Step by step setup Hughes 9201 The Access Portable uses the Automatic Context Activation ACA feature of the Hughes 9201 to activate a PDP context after the terminal is registered with the BGAN Network The Access Portable cannot manually configure the Hughes 9201 to establish a PDP context To set up the Hughes 9201 to establish a PDP context automatically simply change the Access Portable IP address as follows a Use the menu at the top of the screen on the Access Portable to select Network gt Manage Networks b Select Ethernet Port on the main screen and click Configure at the bottom left of the screen c Inthe window that appears select the TCP IP tab and uncheck Acquire address automatically DHCP d Seta static IP address between 192 168 128 210 to 192 168 128 219 Once the Access Portable is ready to broadcast to the BGAN IP network it will automatically open a 32kbps Streaming IP data connection e Set the Subnet mask to 255 255 255 0 and the gateway to 192 168 128 100 default f You may want to enter a DNS server provided by your ISP if you are calling an IP address this is not needed g Click Save Connecting to BGAN As with all the terminals connect using an Ethernet cable a If you need to acquire a new GPS then do so Consult the Getting started with Hughes 9201
6. DY inmarsat DEWY COMRER Using Comrex ACCESS over BGAN Version 1 0 15 01 2008 inmarsat com bgan Whilst the information has been prepared by Inmarsat in good faith and all reasonable efforts have been made to ensure its accuracy Inmarsat makes no warranty or representation as to the accuracy completeness or fitness for purpose or use of the information Inmarsat shall not be liable for any loss or damage of any kind including indirect or consequential loss arising from use of the information and all warranties and conditions whether express or implied by statute common law or otherwise are hereby excluded to the extent permitted by English law INMARSAT is a trademark of the International Mobile Satellite Organisation Inmarsat LOGO is a trademark of Inmarsat IP Company Limited Both trademarks are licensed to Inmarsat Global Limited Inmarsat Global Limited 2007 All rights reserved The mobile satellite company Contents 1 Overview O a A WwW WN 6 1 6 2 6 3 6 4 6 5 6 6 Product range Typical users Key Features Benefits to BGAN users Setting up Step by step setup EXPLORER 300 500 527 and 700 Step by step setup EXPLORER 110 formerly Nera WorldPro 1010 Step by step setup Hughes 9201 ACCESS Portable configuration Start your broadcast using ACCESS Equipment needed 7 BGAN customisation 8 Hints and tips 9 Technical summary 10 Further details and support o O O O O
7. N system After registration the LCD main screen will show DATA ACTIVE as shown below Of Bat gt A _ DATA ACTIVE Now go to ACCESS Portable configuration on page 6 Step by step setup EXPLORER 110 formerly Nera WorldPro 1010 This section describes how to set up BGAN for use with Comrex ACCESS and gives an example of a typical configuration when using ACCESS with the EXPLORER 110 terminal This is a one time configuration to set the terminal up so that it connects to the network automatically After the first time you only need to follow the instructions for Connecting to BGAN below The 32 kbps Streaming service should be initiated from the BGAN terminal and needs to be configured from the EXPLORER 110 s built in web server via a computer s web browser Using Comrex ACCESS over BGAN Page 4 Note Although the solution will work on Standard IP there is no quality guarantee so Inmarsat recommends that you utilise the 32kbps Streaming connection To do this a Open your internet web browser and type the following IP address in the address bar 192 168 0 1 System Status Windows Internet Explorer va i r i hae vttp 192 168 0 1 a b Now you should see the web server interface On the left hand navigation select Data connections c Change the connection type by clicking the dropdown box and selecting Streaming 32 kbps d Make sure Data Connection Activation is set to Autom
8. and BGAN terminal should be connected to a switch or directly with Ethernet cables as shown in the diagram above The computer s IP settings should be configured for DHCP The ACCESS IP settings are described below Step by step setup EXPLORER 300 500 527 and 700 The 32 kbps Streaming service should be initiated from the BGAN terminal and can be configured from either the EXPLORER s built in web server via a laptop s web browser or using the LCD interface on the terminal Note Although the solution will work on the Standard IP connection type there is no quality guarantee so Inmarsat recommends that you utilise the 32Kbps Streaming connection Using Comrex ACCESS over BGAN Page 2 The screenshot below shows the settings required as configured via the EXPLORER s web server interface Please consult your EXPLORER manual for more detailed information Thrane amp Thrane DATICRY sion BBR EOD HOME PHONE BOOK MESSAGES CALLS SETTINGS INTERFACES USB LAN R ne raoth Prones ax Gommor PROPERTIES ADMINISTRATION HELPDESK SITE MAP Connecting to BGAN via the terminal s LCD interface aa i E ay P JS by i f gt X i a i N gt a Me di r p eap a ore Ton oare 5 SA A gt gs ot ot As a a ie yh j TA ee a rit INTERFACE STATUS LAM interface NAT Router mods IP Header compression bled DHCP status guebled Local IP address I gt Meliriss
9. atic when any PC is connected to the Nera WorldPro e Before you exit the web interface make sure you click Store Settings Data Connection Settings Windows Internet Explorer Go 6 http 192 168 0 tu dated srl we dh s Data Connection Settings Thrane amp Thrane Traffic Logs SIM Access Provider Name APN BGAN INMARSAT COM User ed APN Te Text Messages BGAN INMARSAT COM Data Connections Apply user defined APN C User name Oooo Password ee Bluetooth Send static IP address to network o l jo j settings 2 Data connection activation Diagnostic Report Manual Automatic when any PC is connected to Nera WorldPro Automatic when a specific PC is connected Automatic when a static IP address PC is connected to Nera WorldPro Status Information Refresh status Connection Status Not Connected IP address for connected PC 192 168 0 100 Network assigned IP address Connect Connecting to BGAN You can connect to BGAN in two different ways from the web server interface or by using the terminal s front panel To use the front panel a Power on the terminal by pressing and holding the ACTIVATE button for 1 5 seconds Using Comrex ACCESS over BGAN Page 5 6 3 6 4 Using Comrex ACCESS over BGAN b Obtain a GPS fix c Find the best signal d Press the ACTIVATE button to automatically register to the network Wait approx 30 seconds and you should be able to connect to
10. dphone 1 8 3mm unbalanced stereo line level 1 8 8mm unbalanced hands free mobile 1 8 8mm DIN style external 110 220V auto switching rechargeable LION battery 12V DC connector optional Via web browser to integrated web server integrated TFT display Page 8 10 Further details and support Inmarsat contact E Mail customer_care inmarsat com Comrex contact Comrex Corporation 19 Pine Road Devens MA 01434 USA 978 784 1776 office 978 784 1717 fax info comrex com www comrex com Using Comrex ACCESS over BGAN Page 9
11. k ep tp Dynamiz IP address Static IP address APN Ootam ran C gim defaut C Webwork ass gned l User defined Leer vama Pazsucrd PROFILES Primary Seconcar PROFILE CIDS peviile Slrea sine SZ analy Sancel Enzhled Pisahlad l Madem mode C Disabled O Disabled hez foc fp h LE E E Jaen INV ARSAT COM Standsrd Stream ng C4 stream ng 12s 123K tD FES trerdefinad 2 tserdecfinad 2 standard Jtrerdefinad 2 tserdefinad 3 Phangesdn punciles inn the SN interface anple ahave ar in AAminict atinn pages wil uly bake effeut a hen te eulivellng altecdy sciected pitiless amp rtisata For security reasons a Streaming IP connection needs to be started manually This is to ensure that per minute charges do not inadvertently accrue when the EXPLORER terminal is switched on and allows you to more carefully monitor usage and connection time The screenshot below shows you how to set up using the EXPLORER s LCD interface a To initiate a connection from the LCD interface go to the main view of the LCD Using Comrex ACCESS over BGAN Page 3 6 2 b Press the arrow down button until the CONNECT menu displays e Select START and press OK The following screen displays ARE YOU SURE CANCEL OK ee EE n Press OK to confirm the Streaming connection and wait a minute or two to allow the EXPLORER to register the Packet Switched connection with the BGA
Download Pdf Manuals
Related Search
Related Contents
Computer Gear 1.0m UK Male/IEC C13 female MDR-5000 User Manual Samsung ST6500 User Manual FCB-MA130 USB3.0 Board UVC Device Evaluation Software User's NGS Soul Massive Table lamp 66010/53/20 INSTALLATION & OPERATING INSTRUCTIONS ENGLISH - Orthofix ABS Logitech Harmony 700 Advanced Universal Remote Copyright © All rights reserved.