Class II, Type A2 and B2 Biological Safety Cabinets
Contents
1. Exhaust Collar Exhaust HEPA Filter Blower Downflow ULPA Filter angled Downflow Sensor Standard UV light Retrofit Kit Provision Single piece Stainless Steel Work Tray Pressure Switch Port Exhaust Sensor Electrical Electronic Panel Fluorescent Lamp Standard IV bar Retrofit Kit Provision Maximum load for IV bar is 6 kg 13 Ibs Service Fixture Retrofit Kit Provisions 2 on each side Electrical outlet Retrofit Kit Provision 0 9 meter 3 model one single outlet in workzone 1 2 1 5 1 8 and 2 4 meter 4 5 6 amp amp models two single outlets in workzone 970 mm 1270 mm 1570 mm 1870 mm 2440 mm aie el 38 2 50 0 61 8 73 6 96 0 1115 mm 1420 mm 1725 mm 2030 mm 2600 mm 43 9 55 9 67 9 79 9 102 4 15 Stainless Steel Arm Rest 16 Drain Valve Retrofit Kit Provision 17 Esco Sentinel Gold Microprocessor pee OM ae i ay ie Control System 18 Safety Glass Sliding Sash Window Il TYPE B2 BIOSAFETY CABINET A combination of inflow and downflow air streams forms an air barrier that prevents contaminated room air from entering the work zone and prevents work surface emissions from escaping the work zone The downflow combined with the inflow air enters the common air plenum Al
2. ulture O pmi i P Lat Labculture g A vo miS NSF 49 UL 61010 JIS K3800 SFDA YY 0569 EN 12469 SANS 12469 La D C U U re RELIANT Labculture Class Il Type A2 Biosafety Cabinet Model LA2 4A_ E Class ll Type A2 and B2 Biological Safety Cabinets The Most Certified Energy Efficient Safe and Ergonomic Biosafety Cabinet in the World h t P i ARIS Ep m J A gt E E z z i A a Faa IA ESCO WORLD CLASS WORLDWIDE LABCULTURE CLASS II TYPE A2 LA2 and B2 LB2 BIOSAFETY CABINETS informenion to Building Managenent System BMS Zero Volt Relay Contact to turn ON OFF exhaust blower and signal the building Airflow Sensor alarm Monitors real time airflow for safety Alert the user if airflow is insufficient E gaS e ESCO SentineleGOLp MICROPROCESSOR CONTROL SYSTEM Sentinel Gold Microprocessor Controller Displays all safety information on one screen Centered and angled down for easy reach amp viewing Selectable Quickstart mode for fast operation Single Piece Wall Large radius for easy cleaning Side mounted electrical outlets and staggered service fixtures for easy reach Single Piece Work Tray Recessed to contain spillage Curved grill to prevent blockage Raised Arm Rest Helps prevent grille blocking Comfortable working posture Angled Drain Pan m Easy to clean A
3. 13 sq ft 229 mm 9 229 mm 9 229 mm 9 203 mm 8 203 mm 8 274 mm 10 8 274 mm 10 8 274 mm 10 8 248 mm 9 8 248 mm 9 8 Inflow 0 53 m s 105 fom Downflow 0 35 m s 70 fom 0 35 m s 70 fom 0 35 m s 70 fom 0 33 m s 65 fom 0 33 m s 65 fom Inflow 424 m h 251 cfm 555 m h 328 cfm 686 m h 406 cfm 724 m h 426 cfm 945 m h 560 cfm Downflow 628 m h 363 cfm 822 m h 476 cfm 1016 m h 588 cfm 1210 m h 700 cfm 1579 m h 914 cfm Exhaust 424 m h 251 cfm 555 m h 328 cfm 686 m h 406 cfm 724 m h 426 cfm 945 m h 560 cfm Required Exhaust With Optional Thimble 529 m h 311 cfm 764 m h 450 cfm 1116 m h 657 cfm 1164 m h 685 cfm 1540 m h 913 cfm Exhaust Collar Static Pressure For Optional Thimble 32 Pa 0 12 in H O 49 Pa 0 19 in H O 62 Pa 0 24 in H O 79 Pa 0 31 in H O 100 Pa 0 40 in H O Exhaust Collar ULPA Filter Typical Efficiency Sound Emission gt 99 999 for particle size between 0 1 to 0 3 microns per IES T RP CC001 3 H14 per EN 1822 Fluorescent Lamp Intensity Cabinet Construction Electrical gt 114 foot candles gt 130 foot candles gt 100 foot candles gt 114 foot candles NSF ANSI 49 62 5 dBA 63 dBA 63 5 dBA 64 dBA 64 5 dBA EN 12469 59 5 dBA 60 dBA 60 5 dBA 61 dBA 61 5 dBA gt 1230 Lux gt 1400 Lux gt 1070 Lux gt 1230 Lux gt 1230 Lux gt 114 fo
4. green Programmable UV time airflow amp sash LB2 Display check the cabinet operating control buttons for fan blue for FL light timer extends status inflow and downflow Z LE EL parameters and assist servicing provides good lights and outlets and UV lamp life velocities and status remarks tactile feedback orange for UV lamp on one screen without scrolling Also serves as audible alarm mute button DA ver DIAGNOSTICS SY Sentinele GcoLD MICROPROCESSOR CONTROL SYSTEM Accessories for Labculture and Labculture Reliant Biological Safety Cabinets beuen Model Description JAAA GPA Leveling Feet Stand Sitting Posture Adjustable 28 to 30 _ Indicates Size in Feet 3 4 5 6 Example SPL 4 AO gen2 for 4 ft Shipped Flat SPL _BO gen2 Leveling Feet Stand Standing Posture Adjustable 34 _ Indicates Size in Feet 3 4 5 6 Example SPL 4B0 gen2 for 4 ft Shipped Flat SPL BO Gen2 JKE CPA Caster Wheel Stand Sitting Posture 710 mm 28 Fixed Height _ Indicates Size in Feet 3 4 5 6 Ex SPC 4 AO gen2 for 4 ft Shipped Flat S a Caster Wheel Stand Standing Posture 860 mm 34 Fixed Height _ Indicates Size in Feet 3 4 5 6 Ex SPC 4B0 gen2 for 4 ft Shipped flat TL _A STL _AO Telescoping Feet Stand Manually Adjustable 28 to 36 by Pins _ Indicates Size in Feet 3 4 5 6 Example STL 4A0 for 4 ft Shipped Flat U SPM _A_ Hydraulic Stand Electrically Adjustable 28 to
5. 36 _ Indicates Size in Feet 4 5 6 Example SPM 4A1 for 4 ft 230 V Shipped assembled SF 1_40 Service Fixture Indicate the type on the blank _ as follows G Gas V Vacuum W Water Example SF 1G40 for Gas SPM 4A1 IV XXXX IV bar kit Includes 6 hooks Max Load 6 Kg 13 Ibs Specify model when ordering Field installed XXXX Internal width in mm minus 10 mm DYN Wile O Air Tight Damper for all Class II LA2 Cabinets 9 8 diameter x 9 8 height fits inside 10 duct ECO LA2 _ Thimble exhaust transition for LA2 cabinets Specify size when ordering e g ECO LA2 4 for 4 feet DAMPER 10 ABBV 10 Anti Blow Back Valve automatically shuts exhaust preventing back flow in the duct 10 diameter DIG NE SyANG Plastic decon bag for formalin decon on all BSC PORT Air tight cable port installed on right side wall Holds 1 to 4 cables Specify When Ordering ECO LA2 _ FOOT REST Ergonomic Foot Rest free standing angled surface easily adjustable from 3 to 11 in 1 increment 20 wide Black Rubber Matte PVC ARM PVC Armrest for Operator Comfort Easy to Clean 28 Long ABBV 10 M POUCH Microscope Viewing Pouch Factory Installed Specify when Ordering Comprehensive Performance Testing At Esco Every Labculture model manufactured by Esco is individually tested documented by serial number and validated with the following test methods m nflow and downflow velocity m PAO aerosol challenge for fi
6. Lux gt 1200 Lux gt 1200 Lux gt 111 foot candles Electro galvanized steel with white oven baked epoxy polyester Isocide antimicrobial powder coated finish Construction Work Zone Stainless steel Type 304 with No 4 finish Electrical Nominal Power Consumption Net Weight Shipping Weight Shipping Dimensions Maximum W x D x H Shipping Volume Maximum Full Load Amps 230 V 45A 5 5A 5 7 A 6A 6 5A Full Load Amps 115 V 9A 11A 11 5A 12A 13A Heat Load 566 BTU Hr 645 BTU Hr 781 BTU Hr 860 BTU Hr 1177 BTU Hr 166 W 189 W 229 W 252 W 345 W 279 kg 615 Ibs 317 kg 699 lbs 359 kg 791 Ibs 438 kg 966 Ibs 591 kg 1304 Ibs 318 kg 703 Ibs 370 kg 814 Ibs 402 kg 886 Ibs 491 kg 1083 Ibs 651 kg 1435 lbs 1210 x 950 x 1950 mm 47 6 x 37 4 x 76 8 1520 x 950 x 1950 mm 59 8 x 37 4 x 76 8 1900 x 950 x 1950 mm 74 8 x 37 4 x 76 8 2150 x 950 x 1950 mm 84 7 x 37 4 x 76 8 2720 x 950 x 1950 mm 107 0 x 37 4 x 76 8 2 24 m 79 1 cu ft 2 82 m 99 6 cu ft 3 52 m 124 3 cu ft 3 98 m 140 6 cu ft Height includes exhaust collar and depth includes the remove able arm rest and front cover When they are removed depth is 790 mm 31 1 5 04 m 178 0 cu ft This Concurrent Balance Value CBV Exhaust Volume per Pitot Duct Traverse and Static Pressure at cabinet exhaust con
7. access The cabinet shall accommodate an optional mounting stand for fixed height or adjustable height configurations The cabinet shall be equipped with arm rest that is raised above the inflow grille to improve comfort and prevent the operator s arms from blocking the inflow grille The arm rest shall be made from one piece Stainless steel 304 that can withstand decontaminant agents and UV lamp F Certification Service and Decontamination 34 35 36 37 The cabinet shall be approved for both hydrogen peroxide vapor HPV and formaldehyde decontamination protocol All panels leading to potentially contaminated and or hazardous areas shall be color coded red All components with the exception of blower motor and ULPA filters shall be located outside of contaminated air spaces to facilitate servicing without the need to decontaminate the cabinet All exterior surfaces shall be painted with a permanent antimicrobial inhibitor coating to minimize contamination G For Cabinets with Microprocessor Control 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 System LA2 and LB2 Not applicable for LR2 All cabinet functions shall be managed by a programmable microprocessor control system capable of software updates via Internet email downloads The microprocessor controller shall be centrally mounted on the main control panel angled do
8. certified to NSF and SFDA EN 12469 and JIS K 3800 are applicable in LA2 model only mmm JET CLASS WORLDWIDE LABCULTURE RELIANT CLASS II TYPE A2 BIOSAFETY CABINETS ISCCISE powder coat m Silver ion impregnated powder coat m Inhibit microbial growth to improve safety Dynamic Chamber m Blower plenum and side walls are surrounded by negative pressure m Prevent contaminants from escaping outside Positive pressure Negative pressure Single Piece Wall m Large radius for easy cleaning m Side mounted electrical outlets and staggered service fixtures for easy reach Single Piece Work Tray m Recessed to contain spillage m Curved grill to prevent blockage Raised Arm Rest m Helps prevent grille blocking m Comfortable working posture 3 4 5 6 and 8 Shown with optional telescoping stand Angled Drain Pan Easy to clean Does not harbor contaminants NSF 49 UL 61010 Labculture Labculture RELIANT LA2 amp LR2 Class Il Type A2 LB2 Class Il Type B2 Biological Safety Cabinets FEATURING SIMPLE SWITCHES AND GAUGE Energy Efficient ECM Motor m Powered by latest generation ECM motor that is more efficient than legacy ECM and VFD motors m 70 Energy savings compared to AC motor mi Stable airflow despite building voltage fluctuations amp filter loading mi Night Setback mode to further reduce power consumption by 60 Power Canaumption in Watts f
9. chamber shaped steel plenum that is integrated with the removable ULPA HEPA filters to simplify filter changing Fabric plenum is not allowed The integral damper shall be externally adjustable without the need to decontaminate the cabinet D Cabinet Design Construction Cleaning 17 18 19 20 21 22 23 The cabinet shall be of triple wall design whereby all positive pressure plenums handling contaminated air shall be surrounded by negative pressure No positive pressure areas shall be accessible external to the cabinet The third wall shall conceal utilities The cabinet shall have a one piece stainless steel 304 side and back wall with gt radius back corners to allow easy surface decontamination Siliconed joints and 90 bends on the back corners are not allowed because they are hard to clean and can harbor contaminants The work tray shall be one piece integrated with the front grille removable stainless steel grade 304 with 45 angle on all sides without crevices or joints The cabinet shall have a stainless steel grade 304 one piece drain trough with 45 angle on all sides with smooth polished corners to enable easier surface decontamination No 90 angle is allowed on any side of the drain trough The closed side wall below the normal sash operating height shall be sealed without perforations return air slots or concealed areas which can harbor contaminants The cabinet shall b
10. 45 m 4 8 sq ft 0 6 m 6 5 sq ft 0 75 m 8 1 sq ft 0 9 m 9 7 sq ft 1 2 m 13 sq ft Tested Opening 203 mm 8 0 203 mm 8 0 203 mm 8 0 203 mm 8 0 203 mm 8 0 Average Airflow Inflow 0 53 m s 105 fpm Velocity Downflow 0 31 m s 60 fpm Inflow 376 m h 223 cfm 492 m h 292 cfm 608 m h 361 cfm 724 m h 429 cfm 945 m h 560 cfm Downflow 628 m h 363 cfm 822 m h 476 cfm 1016 m h 588 cfm 1210 m h 700 cfm 1580 m h 914 cfm Airflow Volume CBV Exhaust Air Volume 1127 m h 658 cfm 1476 m h 862 cfm 1824 m h 1065 cfm 2173 m h 1269 cfm 2835 m h 1656 cfm Min Exhaust Static Pressure 400 Pa 1 6 in H 0 375 Pa 1 5 in H O 375 Pa 1 5 in H O 400 Pa 1 6 in H 0 475 Pa 1 9 in CBV Exhaust Static Pressure 575 Pa 2 3 in als 550 Pa 2 2 in H 0 550 Pa 2 2 in H 0 575 Pa 2 3 in H O 650 Pa 2 6 in H 0 Supply ULPA Filter Typical Efficiency Exhaust HEPA Filter Typical Efficiency Maximum Sash Opening 299 999 for particle size between 0 1 to 0 3 microns gt 99 99 at 0 3 microns Sound Emission Fluorescent Lamp Intensity At Zero Ambient Cabinet ilaia Boch gt 116 foot candles gt 130 foot candles gt 111 foot candles gt 111 foot candles 508 mm 20 NSF ANSI 49 57 58 59 60 61 EN 12469 54 55 56 s 58 gt 1250 Lux gt 1400 Lux gt 1200
11. N cen AW 5 Ba m Does not harbor contaminants F Bo Sa i EN12469 NSF 49 UL 61010 JIS K3800 SFDA YY 0569 EN 12469 SANS 12469 Esco Labculture Class II Type A2 LA2 has passed more performance tests in more languages for more certifications throughout more countries than any other biological safety cabinet in the world Labculture Labculture RELIANT LA2 amp LR2 Class Il Type A2 LB2 Class Il Type B2 Biological Safety Cabinets FEATURING ADVANCED MICROPROCESSOR CONTROLLER Energy Efficient ECM Motor m Powered by latest generation ECM motor that is more efficient than legacy ECM and VFD motors m 70 Energy savings compared to AC motor mi Stable airflow despite building voltage fluctuations amp filter loading mi Night Setback mode to further reduce power consumption by 60 Pressure Switch LB2 only m Temperature independent Powar Consumption im Walis for Various m Fast response Input Voltage att A2 BSC with ECM amp VFO Gomina A oor me f Lom A meni woke Mecho i Pp mm TA Esca LAJE URIE hail Fi ariy h chun l Ei ECH mai AJ WA able aei yoii i E EER et i w A adie arfor 400 ULPA Filter m 10x Filtration efficiency of HEPA filter mi Creates ISO Class 3 work zone instead of industry standard ISO Class 5 Esco cabinets use ULPA filters per f IEST RP CC001 3 H14 per EN Pa amp Labculture 1822 instead of H13 HEPA filters Se TATA used on many BSCs in the ma
12. a Jakarta Indonesia Osaka Japan Kuala Lumpur Malaysia Melaka Malaysia Manila Philippines Singapore Seoul South Korea Salisbury UK Philadelphia PA USA Hanoi Vietnam Q cscogiobal com ISsScIDe um LIVE SUPPORT Iw wie Esco Micro Pte Ltd PT Esco Bit ntan Indonesia Cert No 651076 Cert No 651333 E gical Safety Cabinet_LA2LB2LR2_combined_brochure_A4_vA_Sept 2013 Esco can accept no responsibility for possible errors in catalogues brochures and other printed materials Esco reserves the right to alter its products and specifications without notice All trademarks and logotypes in this material are the property of Esco and the respective companies 9010185_Biolo PT Esco Bintan Indonesia Cert No Q2N130383797001
13. e A2 can be used to handle minute quantities of volatile toxic chemicals and trace amounts of radionucleotides when vapor Power Rating Voltage VAC Frequency Hz Example 230 50 LA2 4A1 115 60 LA2 4A2 230 60 LA2 4A3 thimble ducted re circulation Use this option if into the work zone is chemical permitted ESO WORLD CLASS WORLDWIDE 10 Labculture Class Il B2 External Without Base Stand Dimension With Optional Base Stand 711mm 28 type WxDxH Internal Dimensions W x D x H Class Il Type B2 Biological Safety Cabinets TECHNICAL SPECIFICATIONS LB2 3B_ E 1115 x 852 x 1610 mm 44 0 x 33 5 x 63 3 LB2 4B E 56 0 x 33 5 x 63 3 1420 x 852 x 1610 mm Rs Ye gt a 1725 x 852 x 1610 mm 68 0 x 33 5 x 63 3 LB2 6B_ E 2030 x 852 x 1610 mm 80 0 x 33 5 x 63 3 LB2 8B_ E 2600 x 852 x 1610 mm NG2 y 33 5 Goce 1115 x 852 x 2321 mm 44 0 x 33 5 x 91 4 1420 x 852 x 2321 mm 56 0 x 33 5 x 91 4 1725 x 852 x 2321 mm 68 0 x 33 5 x 91 4 2030 x 852 x 2321 mm 80 0 x 33 5 x 91 4 2600 x 852 x 2321 mm 102 4 x 33 5 x94 970 x 623 x 715 mm 38 2 x 24 5 x 28 1 1270 x 623x 715 mm 50 0 x 24 5 x 28 1 1570 x623 x 715 mm 61 8 x 24 5 x28 1 1870 x623 x 715 mm 73 6 x24 5 x28 1 2440 x 623 x 715 mm 96 0 x 24 5 x 28 1 Usable Work Area 0
14. e free of sharp edges nonfunctional protrusions bolts screws or hardware and all metal edges shall be deburred The cabinet exterior top shall be slanted to discourage placement of foreign objects and to maintain proper exhaust airflow E Ergonomics and Convenience 24 25 26 27 28 29 30 31 32 33 The front sash shall be frameless to maximize visibility Sash glass shall be safety glass The sash counterbalance shall be suspended on two high strength cables and for safety the sash shall lock into position in the event one cable becomes detached Magnetic not mechanical proximity sensors shall work in conjunction with the control system to indicate proper sash position for containment Fluorescent lamps shall be mounted behind the control panel module out of the work zone Electronic ballasts shall be used to eliminate flicker extend lamp life and reduce heat output The UV lamp shall operate via an automatic timer with automatic shut off to extend the UV lamp life and shall be interlocked with the blower motor and fluorescent lights for safety The cabinet shall be designed with a 10 angled front to optimize user comfort reduce glare and maximize reach into the work area The front grille shall be angled to prevent airflow blockage by accidental placement of objects Penetrations for petcocks and service fittings shall be provided penetrations shall be offset to improve user
15. ed to give large Nominal Airflow A No Personnel ULPA filtered air f S Product Protection performance envelope that provides operator ieee one llieroduceRrsiecion Unfiltered potentially contaminated air and product protection at wide Inflow and E Area of no Personnel een H Area of Personnel i r EE Downflow variation from the Nominal point are nee Product protection Model LA2 and LR2 Biological Safety Cabinet Technical Specifications mae 1540 mm 60 6 1540 mm 60 6 690 mm 27 2 _970 mm 1270 mm 1570 mm 1870 om 20a FE i 14 170 mm 6 7 la mm 1270 mm 1570 mm 1870 mm 2440 Mm mm 175mm 38 2 50 0 61 8 73 6 96 0 623 mm 24 5 38 2 50 0 61 8 73 6 96 0 6 9 1115 mm 1420 mm 1725 mm 2030 mm 2600 mm 815 mm 32 1 _ 1115 mm 1420 mm 1725 mm 2030 mm 2600 mm 43 9 55 9 67 9 79 9 102 4 352 mm 33 5 43 9 55 9 67 9 79 9 102 4 1 Airflow Sensor LA2 only exhaust and alarm system outlet in workzone 1 2 1 5 1 8 15B LR2 Simple Switches Controller 2 Exhaust ULPA Filter 8 Electrical Electronics Panel and 2 4 meter 4 5 6 amp 8 models Pressure Gauge and Manual UV Timer 3 Energy efficient ECM Blower 9 Fluorescent Lamps two single outlets in workzone 16 Safety Glass Slidi
16. l air in the common plenum is HEPA filtered and exhausted via a dedicated ducting system to the external environment 315 mm 12 4 Recommended B2 Cabinet Installation Preferably one blower per individual cabinet and Connected to Emergency Power Pitot Tube Duct Traverse Penetration Drill Penetrations in Ductwork 19 Single piece Stainless Steel Back Wall and Side Walls 20 Removable Side Dress Panel for plumbing access 21 Pre filter Valve Optional 22 Cabinet Power Inlet i Air Tight Damper Required Enables static pressure to be adjusted as filter loads to maintain airflow volume 23 Zero Volt Relay Contact for exhaust system 24 Zero Volt Relay Contact for remove alarm 25 RS 232 Port m Enables he cabinet to be sealed off during decontamination Note Cabinet shown with optional support stand optional air tight damper optional anti blowback valve and optional exhaust blower Exhaust ductwork is not provided by Esco Anti Blowback 1 s B Labculture Supply Air Make Up for Downflow and Inflow Air Located far away from exhaust blower Ecco CD OOL CLASS WORLDWIDE LA2 and LB2 Sentinel Gold Microprocessor Control System LCD simultaneously displays Diagnostics button to easily Large touchpad Color coded LED
17. le on the control panel to easily check the cabinet operating parameters and sensor calibration to assist servicing The cabinet shall have field calibration mode that simplifies on site calibration A selectable Quickstart mode should be available to automatically turn the blower and lights on off by moving the sash window to the correct position The BSC shall have RS 232 data output port for remote monitoring of cabinet operating parameters TCP IP converter shall be available as an option to connect RS 232 to network for remote monitoring Built in zero volt relay contact to signal the exhaust blower or exhaust damper to turn ON OFF when the cabinet internal blower is turned ON OFF Built in zero volt relay contact to send signal to building remote alarm when the cabinet internal alarm is activated G For Cabinets with Manual Control System LR2 38 Not Applicable for LA2 and LB2 The cabinet shall be controlled by simple rocker switches The switch shall prevent the flourescent lamp and UV lamp from being turned on at the same time Filter pressure gauge shall be used to continuously monitor the filter plenum pressure Manually adjustable mechanical UV timer shall be used to control the duration of UV lamp activation to prolong the UV lamp ESCO mmm JRELT CLASS WORLDWIDE 11 ESCO GLOBAL NETWORK ART Equipment Biological Safety Cabinets CO Incubators Compounding Pharmac
18. lter integrity m Airflow pattern visualization m Electrical safety to IEC61010 1 m Additional KI Discus containment and microbiological testing are performed on statistical sampling basis Labculture Labculture RELIANT LA2 amp LR2 Class Il Type A2 LB2 Class Il Type B2 Biological Safety Cabinets Class Il Type A2 Biological Safety Cabinets TECHNICAL SPECIFICATION Labculture Class Il A2 LA2 3A_ E LA2 4A_ E LA2 5A_ E LA2 6A_ E LA2 8A_ E Labculture Reliant Class Il A2 Nominal Size External Dimensions WxDxH Gross Internal Dimensions WxDxH Usable Work Area Tested Opening Working Opening Average Airflow Velocity Na OAV TE LR2 3S_ E 0 9 meters 3 LR2 4S_ E 1 2 meters 4 LR2 5S_ E 1 5 meters 5 LR2 6S_ E 1 8 meters 6 LR2 8S_ E 2 4 meters 8 1115 x 852 x 1540 mm 44 0 x 33 5 x 60 6 1420 x 852 x 1540 mm 56 0 x 33 5 x 60 6 1725 x 852 x 1540 mm 68 0 x 33 5 x 60 6 2030 x 852 x 1540 mm 80 0 x 33 5 x 60 6 2600 x 852 x 1540 mm 102 4 x 33 5 x 60 6 970 x 623 x 670 mm 38 2 x 24 5 x 26 4 1270 x 623 x 670 mm 50 0 x 24 5 x260 4 1570 x 623 x 670 mm 61 8 x 24 5 x 26 4 1870 x 623 x 670 mm VIO lt 5 X 20A 2440 x 623 x 670 mm 96 0 x 24 5 x 26 4 0 45 m 4 8 sq ft 0 6 m 6 5 sq ft 0 75 m 8 1 sq ft 0 9 m 9 7 sq ft 1 2 m
19. minum sep arators no wood or fiberboard shall be used in the filter assembly An integral filter guard shall be affixed to prevent damage to the filter media On Class Il A2 the exhaust filter shall further be protected by staggered exhaust damper The filters shall be a individually scan tested by the manufacturer b individually scan tested after assembly and c easily accessible for scan testing on site by means of a dedicated upstream sampling port accessible from within the cabinet The supply filter shall be angled and oriented to the 10 cabinet front angle to optimize downflow uniformity over the work surface and improve the front aperture containment A removable perforated metal diffuser shall be installed below the supply filter to optimize airflow uniformity and to protect the downtflow filter from damage C Blower System 12 13 14 15 16 The cabinet shall have an energy efficient ECM motor that saves 70 energy compared to conventional AC motor The blower motor system shall automatically maintain stable airflow despite building supply voltage fluctuation and increased filter loading Apply only to LA2 and LR2 The cabinet shall incorporate Night Setback Standby Mode to reduce the blower speed when the cabinet is not being used by the operator while maintaining containment at Static condition as verified by Kl Discus The blower motor system shall be enclosed within a dynamic
20. nection should be used when sizing the HVAC exhaust and supply Noise reading in open field condition anechoic chamber Noise reading in normal room varies by room size layout and background noise but may reach roughly 3 4 dBA above these values Cabinet only excludes optional stand Class Il Type B2 can be used to handle volatile toxic chemicals and radionucleotides because by default it s hard ducted Use this option if chemical vapor re circulation into the work zone is not permitted Labculture Labculture Power Rating LA2 amp LR2 Class Il Type A2 LB2 Class Il Type B2 Biological Safety Cabinets Voltage VAC Frequency Hz Example 230 50 LB2 4B1 115 60 LB2 4B2 RELIANT 60 LB2 4B3 Purchase Specifications LA2 Class Il A2 LR2 Class Il A2 LB2 Class II B2 Biological Safety Cabinets A General Performance and Certifications 1 v0 10 11 The biological safety cabinet shall comply with the following international standards and the manufacturer shall provide a certified copy of containment and performance tests equivalent to or greater than specified in the following independent international standards for Class Il per NSF ANSI 49 USA JIS K3800 Japan SFDA YY 0569 China and EN 12469 Europe The cabinet shall protect a the operator and laboratory environment from particulates generated within the work zone b the product and
21. ng Sash Window 4 Downflow ULBA Filter analea 12 Stainless Steel Single piece Work Tray 17 Single piece Stainless Steel Back Wall p any 10 Plugged Service Fixture provisions 2 on and Side Walls oe ni j 13 Stainless Steel Arm Rest 5 UV light Retrofit Kit Provision each side e i ES o l 14 Drain Valve Retrofit Kit Provision 18 Removable Side Panel for plumbing 6 IV bar Retrofit Kit Provision 11 Electrical Outlet Retrofit Kit Provision access 15A LA2 and LB2 only Sentinel Gold 0 9 meter 3 model one single Microprocessor Control System 7 RS 232 Port zero volt relay contacts for Optional Exhaust Collar Positions for Thimble Ducting for LA2 and LR2 Models 370 mm 15 0 for LA2 3A LR2 3S 250 mm g9 8 530 mm 20 9 for LA2 4A LR2 4S 3 128 mm 5 0 4 133 mm 5 2 610 mm 24 0 for LA2 5A LR2 5S 5 137 5 4 711 mm 28 0 for LA2 6A LR2 6S 5l oe 1300 mm 51 2 for LA2 8A LR2 8S 6 138 mm 5 5 Side View All Sizes Top View All Sizes Labculture Labculture RELIANT LA2 amp LR2 Class Il Type A2 LB2 Class Il Type B2 Biological Safety Cabinets For Biohazard and Chemical Hazard 295 mm 11 6 406 mm 15 9 643 mm 25 3 820 mm 32 2 ULPA filtered air L_ Unfiltered potentially contaminated air LB2 CLASS Cabinet Filtration System Side capture zones D
22. or Varmus Input Voltage Aft A2 BSC with ECM amp VFD COren AC mor j in i i A eased wokaqpe Techie ae eas sition analia Eso LLNEILAIE fe Eia ECH maii DN A athe oe viij i ok W _ adits aaarficrwe ULPA Filter mi 10x Filtration efficiency of HEPA filter mi Creates ISO Class 3 work zone instead of industry standard ISO Class 5 Esco cabinets use ULPA filters per IEST RP CC001 3 H14 per EN 1822 instead of H13 HEPA filters used on many BSCs in the market HEPA filters only offer 99 99 typical efficiency at 0 3 micron while ULPA filters provide 99 999 typical efficiency i for particle sizes of 0 1 to 0 3 micron Particle Size um Rocker Switches and Pressure Gauge m Easy to use switches mi Displays filter loading status mi Manually adjustable UV timer ESCO AL SS Ae lS T Chae Fi Tyee AT bheegi ade Cred Emil il ee eee ee ei eee a Se ag ed ee ee er a ee pe Se 2 ee as Adjustable UV Timer mi Easily adjustable to desired minutes or hours m Prolongs UV lamp for not turning it ON overnight Certification Biosafety Cabinets Air Quality Filtration Electrical Safety ISO 14644 1 Class 3 Worldwide EN 1822 H14 Europe UL C 61010A 1 USA JIS B9920 Class 3 Japan IEST RP CC001 3 USA CSA22 2 No 1010 192 Canada JIS BS5295 Class 3 Japan IEST RP CC007 USA EN 61010 1 Europe US Fed Std 209E Class 1 USA IEST RP CC034 1 USA IEC61010 1 Worldwide Standards Com
23. ot candles Electrogalvanized steel with Isocide oven baked epoxy polyester powder coating and Stainless Steel 304 316 is optional 1 5 mm 0 06 16 gauge thick Full Load Amps 230 V 45A 5 5A 5 7 A 6A 6 5A Full Load Amps 115 V 9A 11A 11 5 A 12A 13 A Heat Load 853 BTU Hr 972 BTU Hr 1177 BTU Hr 1297 BTU Hr 1774 BTU Hr 250W 285W 345W 380W 520W Nominal Power Consumption Net Weight Shipping Weight Shipping Dimensions Maximum W x D x H Shipping Volume Maximum 243 kg 536 lbs 283 kg 624 Ibs 350 kg 772 Ibs 426 kg 939 Ibs 580 kg 1279 Ibs 292 kg 644 Ibs 345 kg 761 Ibs 410 kg 904 Ibs 486 kg 1072 Ibs 640 kg 1411 Ibs 1200 x 950 x 1900 mm 47 2 x 37 4 x 74 8 1550 x 950 x 1900 mm 61 0 x 37 4 x 74 8 1950 x 950 x 1900 mm 76 8 x 37 4 x 74 8 2150 x 950 x 1900 mm 84 6 x 37 4 x 74 8 2720 x 950 x 1900mm 84 6 x 37 4 x 74 8 2 17 m 77 cu ft Depth includes the remove able arm rest and front cover When they are removed depth is 790 mm 31 1 Noise reading in open field condition anechoic chamber Noise reading in normal room varies by room size layout and background noise but may reach roughly 3 4 dBA above these values Cabinet only excludes optional stand 2 80 m 99 cu ft 3 52 m3 124 cu ft 3 88 m3 137 cu ft 4 91 m 173 cu ft Class Il Typ
24. pliance NSF ANSI 49 NSF The NSF ANSI 49 certified models are LR2 4S1 E LR2 4S2 E LR2 4S3 E LR2 5S1 E LR2 5S82 E LR2 5S3 E LR2 6S1 E LR2 6S2 E and LR2 6S3 E ESO D OOL CLASS WORLDWIDE LA2 and LR2 CLASS II TYPE A2 BIOSAFETY CABINETS Cabinet Filtration System The Performance Envelope Concept Ambient air is pulled through front grille to 40 50 60 70 80 90 100 fom create inflow without going into the work 0 65 130 fpm surface Inflow is joined by half of the downflow m s to create front air curtain that is fine tuned to create a large performance envelope The combined air stream travels through the back air column towards the blower For Biohazard 0 60 120 0 55 410 Nominal 0 50 0 35 0 53 m s 70 105 fpm Approximately 1 3 of the air in the common plenum is exhausted through the ULPA filter to the room The remaining 2 3 of the air is passed through the downflow ULPA filter and into the work area as a vertical laminar flow air to create ISO Class 3 work surface and prevents cross contamination 0 45 Inflow Velocity 0 40 Near the work surface the downflow splits About Half goes to the front grille and half goes to the rear grille A small portion enters the the side capture zones to prevent dead air corners small blue arrows 0 30 035 040 045 0 50m s Downflow Velocity Dynamic air barrier where inflow and downflow converge Side capture zones l _ l l l The design was optimiz
25. process within the work zone from airborne contamination from ambient air c and the product and process within the work zone from cross contamination The cabinet shall be tested by KI Discus test European Standard EN12469 2000 on statistical sampling basis to validate operator personnel protection The retention efficiency for the front aperture shall be not less than 99 999 Microbiological testing for cabinet performance shall also be performed on a statistical sampling basis Each cabinet shall be listed by Underwriters Laboratories UL CUL or CE for electrical safety Original documentation specific to each cabinet serial number shall be provided with the cabinet and maintained in the manufacturers records Test data verifying all performance criteria shall be available upon request to include a inflow velocity through direct inflow measurement method b downflow velocity and uniformity c filter leak scan with aerosol challenge for both filters d electrical safety Filtration System The cabinet shall have one supply downflow filter and one exhaust filter For Class II A2 Both filters shall be ULPA per IEST RP CC001 3 and H14 per EN1822 For Class II B2 The downflow filter shall be ULPA type per IEST RP CC001 3 and H14 per EN1822 H14 and the exhaust filter shall be HEPA per IEST RP CC001 3 and H13 per EN1822 The filters shall be constructed with aluminum frame with mini pleat media design without alu
26. rket j neta ft tt Cee HEPA filters only offer 99 99 typical 7 eT cee efficiency at 0 3 micron while ULPA git Ee ee Rea Saez coo filters provide 99 999 typical efficiency i 005 010 015 020 025 030 040 0 50 for particle sizes of 0 1 to 0 3 micron Particle Size um Dynamic Chamber m Blower plenum and side walls are surrounded by negative pressure m Prevent contaminants from escaping outside lt lt o SS Positive pressure I Negative pressure SE powder coat m Silver ion impregnated powder coat m Inhibit microbial growth to improve safety d bow Grow ile Hee Min Him socis fima in for The Most Certified BSC in the World Biosafety Cabinets Air Quality Filtration Electrical Safety Standards NSF ANSI 49 USA ISO 14644 1 Class 3 Worldwide EN 1822 H14 Europe UL C 61010A 1 USA Compliance EN 12469 Europe JIS B9920 Class 3 Japan IEST RP CC001 3 USA CSA22 2 No 1010 192 Canada JIS K 3800 Japan JIS BS5295 Class 3 Japan IEST RP CC007 USA EN 61010 1 Europe SFDA YY 0569 China US Fed Std 209E Class 1 USA IEST RP CC034 1 USA IEC61010 1 Worldwide The NSF ANSI 49 certified models are LA2 4A1 E LA2 4A2 E LA2 4A3 E LA2 5A1 E LA2 5A2 E LA2 5A3 E LA2 6A1 E LA2 6A2 E LA2 6A3 E LB2 4B1 E LB2 4B2 E LB2 4B3 E LB2 5B1 E LB2 5B2 E LB2 5B3 E LB2 6B1 E LB2 6B2 E and LB2 6B3 E Note LA2 cabinets are certified to NSF EN JIS and SFDA LB2 cabinets are
27. wn toward the user for easy access and ADA compliant The controller shall include soft touch keypad controls and backlit LCD display to control the blower motor light UV lamp electrical outlet s and menu The LCD shall be large enough to simultaneously display cabinet model clock inflow downflow sash status airflow status and cautionary message should a deviation from normal operating parameters occur The controller shall be user programmable on site to enable or disable functions such as PIN personal identification number access restriction cabinet start up protocol airflow alarm and other microprocessor controlled operations as outlined in the user manual When programmed ON the start up protocol shall perform an automatic pre purge and post purge cycle to ensure proper cabinet operation The controller shall include a blower motor hours meter to display aggregate motor running time to assist in predictive maintenance Audible and visual alarms shall be provided for unsafe conditions such as improper airflow or sash opening The audio alarm shall be able to be muted by the user at adjustable duration and after that the audio alarm is automatically resumed Airflow shall be monitored by a temperature compensating thermistor based true air velocity sensor mounted in the cabinet The airflow display and alarm system shall be individually calibrated before shipment Diagnostics button should be availab
28. y Equipment Containment Pharma Products Ductless Fume Hoods Freeze Dryer Lab Animal Research Products Laboratory Fume Hoods Laboratory Ovens and Incubators Laminar Flow Clean Benches PCR Cabinets PCR Thermal Cyclers Powder Weighing Balance Enclosures Ultra low Freezers 12 The Esco Group of Companies is a global life sciences tools provider with sales in over 100 countries The group is active in lab equipment pharma equipment and medical devices Manufacturing facilities are located in Asia and Europe R amp D is conducted worldwide spanning the US Europe and Asia Sales service and marketing subsidiaries are located in 12 major markets including the US UK Singapore Japan China and India Regional distribution centers are located in the US UK and Singapore Life Science Chemical Research Assisted Reproductive Technology ART Pharmaceutical Equipment General Equipment EScO WORLD CLASS WORLDWIDE Esco Technologies Inc 2940 Turnpike Drive Units 15 16 e Hatboro PA 19040 USA Toll Free USA and Canada 877 479 3726 e Tel 215 441 9661 Fax 215 441 9660 us escoglobal com usa escoglobal com Esco Micro Pte Ltd e 21 Changi South Street 1 e Singapore 486 777 Tel 65 6542 0833 Fax 65 6542 6920 mail escoglobal com www escoglobal com Esco Global Offices Manama Bahrain Beijing China Chengdu China Guangzhou China Shanghai China Bangalore India Delhi India Mumbai Indi
29. ynamic air barrier inflow and forward directed downflow air converge Ambient air is pulled through the front grille to prevent contamination of the work surface and work product The inflow does not mix with the clean air within the cabinet work zone Ambient air is taken in through a pre filter at the top of the cabinet and passes through the downflow ULPA filter entering the work zone as laminar flow The uniform non turbulent air stream protects against cross contamination within and throughout the work area Near the work surface the downflow air stream splits with a portion moving toward the front air grille and the remainder moving to the rear air grille A small portion of the ULPA filtered downflow enters the intake perforations MA es at a higher Model LB2 Biological Safety Cabinet Technical Specifications LB2 3 LB2 4 LB2 5 LB2 6 a ES ES eS 1300 mm 51 2 LB2 8 iil 251 mm 9 8 70 mm 2 7 Be dbb 1610 mm 63 3 1540 mm 60 6 5 a 00 N HHHH HH oe
Download Pdf Manuals
Related Search
Related Contents
iQ7 XTREME IN CAR KIT Installation & Operating Instructions Toshiba Satellite S855-S5168 Tigo Energy Limited Warranty: Management Unit and Gateway LAVADORA SEMI-AUTOMÁTICA ELATION WW PROFILE - USER MANUAL ver 1 Betriebsanleitung Operating Instructions Instructions de service Liebert® Challenger™ 3000 with Liebert iCOM® Brother MFC-8420 All in One Printer User Manual Copyright © All rights reserved.