1. a OON Ebon S 10 kO Distortion gt factor 10 L 500 3 O o Lu 1 1 Yo o D 100 mV o 100 Q 50 O 10 5 RL 10 Q9 O 1 100 uV 10 1 10 100 mA 1 10 100 1 000A Thru current lo A r m s OMRON E5CZ E5CZ U External Connections e A voltage output control output 1 is not electrically insulated from the internal circuits When using a grounding thermocouple do not connect any of the control output terminals to ground If the control output terminals are connected to ground errors will occur in the measured temperature values as a result of leakage current E5CZ Relay output 250 VAC 3 A t E Alarm output Relay output Resistive load Control output 1 Alarm output 2 A AM output Relay Valzqeouipil pute output 250 VAC 1 A Al HB alarm HS isti 12 VDC 21 mA care All T a Resistive load Current output m i 4 to 20 mA DC 0 to 20 mA DC 3 i Load 600 Q max nput power supply 100 to 240 VAC sania input TOIPt 24 VAC DC no polarity universal input Option Units E53 CZH03 E53 CZHB E53 CZ03 E53 CZB Communications Event inputs Communications Event inputs CT CT re amp 1 D r8 1 D bee Dra Le Le A 12 EV1 2 a 2 EV1 03 Do not Do not use EV2 3 use 3 EV2 3 Do not Do not 14 use A use A a Do not Do not 15 use 15 use 15 E5CZ U Alarm output Rel
2. Transfer output lower limit Linear current output Input digital filter Linear output Move to advanced function setting level p Displayed when initial setting communications protection is col serio O Move by setting password 169 OMRON E5 IZ Improved Functions Changes Model numbers have been changed to allow for universal input Precautions in Replacing Previous Controllers specifications e Previous E5OZ Controllers cannot be removed from the case for Before Change replacement with new models Replace the case at the same time E5UZ ULILI models for thermocouples and platinum resistance thermometers None models for analog input None models for 24 VAC VDC After Change E5UZ LLILIT models for thermocouples and platinum resistance thermometers E5 _JZ JLILIL models for analog input ES5SUZ OULLID models for 24 VAC VDC The following items have not changed in comparison to the previous ESLIZ models Panel cutout Internal panel dimensions for panel mounting wiring screw sizes wiring terminal arrangement and parameter setting methods Ee ey a Be ee a ge ge ee ee et ee ee ge cf aaron Functions The previous and new models can be easily differentiated by looking at the front panel The OMRON logo is in a different position Item Previous models OMRON logo lower left Impro
3. Characteristics 5 When using the E53 AZB E53 AZ01 or E53 AZ03 Option Unit with the E5AZ LIBUMLIL to satisfy the immunity burst ee ine sth Dee eee pa requirements in the EN 61326 standard always connect a ie ee a E Filter manufactured by TDK to the att Platinum resistance thermometer e for terminals 11 12 and 13 Indication accuracy 40 5 of indicated value or 1 C whichever is greater 1 ae digit max Analog input 0 5 FS 1 digit max CT input 5 FS 1 digit max USB Serial Conversion Cable Influence of tempera R S and B thermocouple inputs z ture See note 2 1 of PV or 1 ai whichever is greater 1 digit max Applicable OS Windows 2000 XP Vista Other thermocouple inputs a 41 of PV or 4 C whichever is greater 1 digit max Applicable software Thermo Mini 410 C for 100 C or less for K sensors i Influence of voltage Platinum resistance thermometer inputs Applicable models ESCZ IESCZ U ESAZIESEZ See note 2 a of PV or 2 C whichever is greater 1 digit max USB interface standard Conforms to USB Specification 1 1 nalog inputs t1 of FS 1 digit max DTE speed 38400 bps Models with thermocouple platinum resistance thermometer Computer USB type A plug Hysteresis ee 909 9 EU tit units of 0 1 EU See note 3 Connector specifications Temperature Controller Setup Tool port Models with analog input on bottom of Controller 0 01 to 99 99 FS in units of 0 01 FS Bus power Suppli
4. New Product on RON Digital Temperature Controllers E5 12 1 16 1 8 and 1 4 DIN Temperature Controllers Join the Best selling E5 Z Series e Models available with either temperature inputs or A analog inputs 999 e A wide range of functions such as a loop break alarm z BE LBA manual output and transfer output aen e Easy to read 11 segment display e Faster sampling at 250 ms e Setting Tool port provided as a standard feature for easy connection to personal computers e New protocol called Modbus is installed in the models with communications Digital Position proportional Controller E5EZ PRR 1 16 DIN 1 8 DIN 1 4 DIN 1 8 DIN NEW NEW NEW Contents Digital Temperature Controllers NEW E5CZ E5CZ U ossee 2 NEW ESAZ ESE Zu eeeeeecceteeeneteeeeeeeees 14 ESEZ PRR Seiedncesciescascnexiwnceeds aieiai eia 37 Common to Updated E5LIZ Controllers Operat OM sanassa 26 PFSC AUT ONS snis 33 E5EZ PRR BCT COU iE E E 43 Precautions c ccccceccecececcececeecececeececaeeecaeaes 59 Digital Temperature Controllers ate O74 10 O74 48 x 48 mm This Best selling General purpose 48x48 mm Temperature Controller Is Now Even Better e Controllers now available with analog inputs e Faster sampling at 250 ms e Transfer output provided for easy output to recorders e Models available with a loop break alarm LBA and heater short alarm HS alarm e Easy setting with 11
5. Analog current voltage input type Current input 4 to 20 mA 0 to 20 mA Voltage input 1 to 5 V 0 to 5 V O to 10 V Relay output Control output OUT1 OUT2 SPST NO 250 VAC 1A resistive load Electrical life 100 000 operations minimum applicable load 5 V 10 mA Potentiometer input 100 Q to 2 5 KQ Alarm output Contact input SPST NO 250 VAC 2 A resistive load Electrical life 100 000 operations minimum applicable load 5 V 10 mA ON 1 kQ max OFF 100 KQ min Event input Non contact input ON Residual voltage 1 5 V max OFF Leakage current 0 1 mA max Outflow current Approx 7 mA per point Control method 2 PID control Setting method Indication method Other functions Ambient operating temperature Digital setting using front panel keys 7 segment digital display and single lighting indicators Character height PV 9 mm SV 7 mm MV 6 8 mm According to controller model 10 to 55 C with no icing or condensation Ambient operating humidity 25 to 85 Storage temperature 25 to 65 C with no icing or condensation Communications Specifications Transmission line connection RS 485 Multidrop RS 232C Point to point Communications method See note 1 RS 485 two wire half duplex RS 232C Synchronization method Baud rate Start stop synchronization 1 200 2 400 4 800 9 600 19 200 bps Communications code ASCII Da
6. Model Number Structure Model Number Legend E5EZ PRROQO 123456 1 Control method 4 Number of alarms 5 Option 6 Input Type P Valve control Blank Not available Blank Not available T Temperature 2 Control output 1 p Two alarms 01 RS 232C L Analog input current voltage R Relay OPEN 03 RS 485 3 Control output 2 B 2 event inputs R Relay CLOSE Ordering Information Communica Power supply Control Number of h Size Input type tions Event input Model voltage method alarms fainction None E5EZ PRRT None None E5EZ PRR2T Temperature i Input Type 7 2 points E5EZ PRR2BT RS 232C E5EZ PRR201T 1 8DIN loa uae None CEEE DDDRoNn2T 100 to RS 485 E5EZ PRR203T 48 x 96 x 78 240 VAC Valve Control W x Hx D None E5EZ PRRL None Analog None E5EZ PRR2L Current i i Voltage Input m 2 points E5EZ PRR2BL Type RS 232C N E5EZ PRR201L None RS 485 E5EZ PRR203L Accessories Order Separately Unit Label Terminal Cover Model Y92S L1 Connectable models Terminal block models Model E53 COV18 omron E5EZ PRR Input Range Thermocouples Platinum Resistance Thermometer Platinum resistance ES1B Infrared Input type hermoneier Thermocouple Analog input 21 L Se lele 0 to 50 mV Name JPt100 T o to to to to 50 m 70 C 120 C 165 C 260 C a p a ae p aa aaa ae ee OT 0 p o a a P A E a E e e we ff PPP ET Ey FF J toning
7. EU stands for Engineering Unit and is used as the unit after scaling For a temperature sensor the EU is C or F 4 B R and S sensors 0 2 C Q max 100 Q max OMRON Heater Burnout and Heater Short Alarms Maximum heater current 50 A AC Input current indication accuracy 5 FS 1 digit max 0 1 to 49 9 A in units of 0 1 A 0 0 A Heater burnout Heater short alarm output turns OFF 50 0 A Heater burnout Heater short alarm output turns ON Minimum detection ON time 190 ms See note 1 Heater burn out alarm setting range 0 1 to 49 9 A in units of 0 1 A 0 0 A Heater burnout Heater short alarm output turns ON 50 0 A Heater burnout Heater short alarm output turns OFF Minimum detection OFF time 190 ms See note 2 Note 1 Ifthe ON time of control output 1 is less than 190 ms heater burnout detection and the heater current will not be measured 2 If the OFF time of control output 1 is less than 190 ms heater short alarm and the heater current will not be measured Heater short alarm setting range Electrical Life Expectancy Curve for Relays Reference Values 250 VAC 30 VDC J resistive load Life x 10 operations Switching current A ES5AZ E5EZ E54 CT1 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Windi
8. output burnout option units E5EZ R3 Relay output No No E5EZ A3 E53 AZR E5EZ R3T Voltage output E5EZ Q3 for driving SSR N E5EZ A3 E53 AZQ ESEZ Q3T E5EZ C3 Current output No E5EZ A3 E53 AZC E5EZ C3T Thermocouple or Relay output No E5EZ R3 E53 AZM E5EZ R3MT a Voltage output thermometer z z 7 a for driving SSR No E5EZ Q3 E53 AZM E5EZ Q3MT 240 VAC Current output No E5EZ C3 E53 AZM E5EZ C3MT Relay output Yes CT1 ESEZ DS ESS AZM ESEZ R3HMT Voltage output E5EZ Q3 E53 AZM Hein for driving SSR 8S 1 E53 AZH PoEE SAET 48 x 96 x 78 Relay output Yes CT1 None E5EZ R3HML nn Analog current Voltage output Yes CT1 E5EZ Q3HML voltage for driving SSR Current output E5EZ C3ML Relay output E5EZ R3MTD Voltage output Thermocouple or for driving SSR No Yes None E5EZ Q3MTD Resistance eee aca No Yes None E5EZ C3MTD Relay output Yes CT1 E5EZ R3HMTD 24 VAC VDC Voltage output Yes CT1 E5EZ Q3HMTD Relay output Yes CT1 E5EZ R3HMLD Analog current Voltage output i voltage for driving SSR veS GEI ESEC OOMMEN ESEZ C3MLD Option Units Name Function Model a RS 232C Communications E53 AZ01 Communications Unit RS 485 Communications E53 AZ03 Event Input Unit Event input E53 AZB Accessories Order Separately USB Serial Conversion Cable Model E58 CIFQ1 Terminal Cover Connectable models Model E5AZ E53 COV11 E5EZ Waterproof Packing Connectable models Mo
9. Proportional band Integral time Unit seconds Derivative time Unit seconds PID settings E5EZ PRR MV at stop Hold Haid Open aPEn Close ZL ASE MV at PV error Hold Haid Open aPEn p Close 1 45E SP ramp set value MV upper limit MV limit value MV lower limit Position proportional dead band Open close hysteresis OMRON E5EZ PRR Operation Adjustment Protect The following table shows the relationship between set values and the range of protection i Set value Operation Level adjustment protect 0 1 2 3 PV Can be displayed Can be displayed Can be displayed Can be displayed Initial setting Can be displayed communications Operation wer and changed Can be displayed Can be displayed and changed and changed Can be displayed proset level Cannot be displayed Cannot be displayed and moving to other and moving to other levels is not possible levels is not possible Can be displayed and changed Can be displayed and changed Others Setting change protect Cannot be displayed Cannot be displayed Cannot be displayed and moving to other and moving to other and moving to other levels is not possible levels is not possible levels is not possible HEHP E EINE EN e Parameters are not protected when the set value is set to 0 key protect e The default is 0 OOOO Can be disp
10. 4 Avoid using the Controller in places near a radio television set or wireless installing These devices can cause radio disturbances which adversely affect the performance of the Controller Mounting E5EZ PRR 1 Insert the E5EZ PRR into the mounting hole in the panel from the front 2 Push the mounting bracket along the E5EZ PRR body from the terminals up to the panel and secure it temporarily 3 Tighten the fixing screw on each mounting bracket alternately until the ratchet stops tightening E5EZ PRR Removing the Temperature Controller from the Case To remove the Temperature Controller from case use a suitable Phillips screwdriver for the screw located at the bottom on the front panel 1 Insert the tools see drawing above into the slots one on the top and one on the bottom and release the hooks 2 Insert the tool in the space between the front and rear panels and slightly pull out the front panel Hold the top and bottom of the front panel and pull toward yourself to remove it 3 Match up the upper and lower claws with the connection points and insert the Option Unit Mount the Option Unit in the center 4 Insert the Unit into the rear case until you hear a click When inserting the Unit press down the hooks on the top and bottom of the rear case so that they firmly hook on the inserted Unit Make sure that electronic parts do not come in contact with the case E5EZ PRR Tool insertion hole Flat
11. B r miIL Communications writing I Derivative time Press the Bas Added Hen au omana pes D a LAE cl OKey for select addition is ON BBS oF at lead 3s ve aa g JEE or py be wie B M 5P Multi SP F AL g Alarm value 2 Be r Heater current 1 value Cooling coefficient E set point setting F52 g S Lei g D pnl Monitor Ve F 4 Heating cool I Set point during SP a m ap Alarm value 2 Ing ramp 5 6 Mupper limit 2 2 Bi r Leakage current 1 Dead band noe u 5 a Coona h Va x On mm BSS Hi Heater current 1 value Bm ay Alarm value Ve 7 i monitor Oa lower limit 2 z 5 wt Heater burnout detection 1 m Manual reset value gas D re Clear the offset during sta Ve y a bilization of P or PD control Leakage current 1 7 m 5 Alarm value 3 E monitor De Ooo Li o Hysteresis heating Va S oF 3 y o Hysteresis RUN STOP ch JH au Satna 3 settings nie Hysteresis cooling Va o g oy J Alarm value BILL ower limit 3 D oc 0 z SP ramp set value Vie D gga g SP used by g7 al MV monitor Vie multi SP Sox og heating CI MV upper limit Vie e fF MV monitor 5 A i Bo 17 cooling MV lower limit Press the LO and cel Keys for at Press the O and a Keys ai i T least 3 s Display flashes for at least 1 s ess than IS Protect Level Communications Setting Level 4 The time taken to move to the protect level can be Displayed only for models with communications
12. Destruction 10 to 55 Hz 0 75 mm single amplitude for 2 hrs each in X Y p tance and Z directions z a Transmission line con RS 485 multipoint Shock Malfunction 100 m s min 3 times each in X Y and Z directions nection method RS 232C resis ae fence Destruction 300 m s min 3 times each in X Y and Z directions Communications RS 485 two wire half duplex RS 232C E5AZ Controller Approx 300 g Mounting Bracket Approx 100 g Synchronization izati Weight pp g m ad Start stop synchronization E5EZ Controller Approx 250 g Mounting Bracket Approx 100 g z I IP66 ina Baud rate 1200 2400 4800 9600 19200 or 38400 bps ront panel indoor use Degree of protection Rear case IP20 Terminals IPOO Transmission code ASCII Memory protection Non volatile memory number of writes 1 000 000 times Data length See note 7 or 8 bits Emission Enclosure EN55011 Group1 Class A Stop bits See note 1 or 2 bits Emission AC Mains EN55011 Group1 Class A Immunity ESD EN61000 4 2 4 kV contact discharge level Vertical parity none even odd A Frame check sequence FCS with SYSWAY 8 kV air discharge level 3 i q Immunity RF interference ge n Block check character BCC with CompoWay F or EN61000 4 3 10 V m CRC 16 Modbus 80 1000 MHz 1 4 2 0 GHz amplitude modulated level 3 Flow control None 10 V m 900 MHz pulse modulated Immunity Conducted Disturbance Interface RS 485 RS 232C EN61000 4 6 3 V EMC 0 15 to 80 MHz le
13. Sampling period Insulation resistance Insulation resistance 20 MQ min at 500 VDC 0 0 to 100 0 in units of 0 1 500 ms Dielectric strength 2000 VAC 50 or 60 Hz for 1min between terminals of different charge Vibration resistance 10 to 55 Hz 20 m s 2for 10min each in X Y and Z directions Shock resistance 100 m s2 3 times each in X Y and Z directions Weight Memory protection EEPROM non volatile memory number of writes 100 000 operations EMC Approx 260 g Emission enclosure Emission AC mains Immunity ESD EN55011 GB T 6113 1 2 1 group type A EN55011 GB T 6113 1 2 1 group type A See note 2 IEC61000 4 2 GB T 17626 2 4 kV contact discharge series 2 6 kV air discharge series 3 Immunity RF interference IEC61000 4 3 GB T 17626 3 10 V m 80 MHz 1 GHz series Immunity conducted disturbance EC61000 4 6 GB T 17626 6 3 V 0 15 80 MHz series 3 Surges shocks IEC61000 4 5 GB T 17626 5 2 kV power supply line series 3 1 kV I O signal line series 4 Approved standards UL61010C 1 CSA C22 2 No 1010 1 Conformed standards EN61326 EN61010 1 IEC61010 1 Note 1 The indication accuracy of K thermocouples in the 200 to 1300 C range T and N thermocouples at a temperature of 100 C max and U and L thermocouples at any temperature is 2 C 1 digit maximum The indication accuracy of the B thermocouple at a temperature of 400 C max is
14. Specifications Sibe EU esi ts temperature testing range Type 2mm 20mm 40 mm 60 mm 10 to 70 C f 60 to 120 C 115 to 165 C ES1B 140 to 260 C ES1 L Series of Infrared Temperature Sensors Able to measure temperatures without contact Damage free clean and effective temperature management e Comes in two spot diameters 3 mm dia and 8 mm dia e Recreation accuracy kept within 0 5 C with a response speed of 0 4 seconds 95 along with high accuracy realizing fast measurement e In addition to the original unit for use in medium temperatures 0 to 500 C there are new models for use in medium to low temperatures 50 to 500 C and high temperatures 0 to 1000 C e New long distance types enable measuring from distances of 500 mm and 1000 mm e By using a programmer order separately it is possible to monitor temperatures as well as make changes to the rate of emissions switches between functions and range of output The picture shows a programmer installed onto an ES1 unit Range of temperature Type measurements Spot dimensions See note 2 Type For use with high 0 to 1 000 C 35 mm dia distance of 1000 mm ES1 LW100H Fi temperatures Below 40 mm dia distance of 500 mm ES1 LW50H For use with medium to 35 mm dia distance of 1000 mm ES1 LW100 50 to 500 C See note 1 low temperatures i l Below 40 mm dia distance of 500 mm ES1 LW50
15. e None 2 level Display PV and SV 4 digit Display Sensor Inputs e Universal thermocouple Pt inputs Models with temperature inputs e Auto manual switching e Models also available with Oe eee gt Alarm Outputs RS 485 or RS 232C e Three communications Control Output 1 e Relay output e Analog current voltage inputs Models with analog inputs Indication Accuracy e Thermocouple input 0 5 of PV e Pt input 0 5 of PV e Analog input 0 5 FS e Voltage output for driving SSR e Current output Sampling Period e 250 ms OMRON Model Number Structure Model Number Legend Controllers E5A2Z EZ _ 3_ JILL 12345 6 1 Control Output 1 R Relay output Q Voltage output for driving SSR C Current output 2 Number of Alarms 3 Three alarms 3 Heater Burnout Heater Short Blank None H Heater burnout Heater short detection CT 1 4 Option Blank None M Option Unit can be mounted 5 Input Type T Thermocouple infrared sensor platinum resistance thermometer L Analog current voltage input 6 Power Supply Voltage Blank 100 to 240 VAC D 24 VAC VDC Ordering Information Controllers with Terminal Blocks ES5AZ E5EZ Option Units E53 AZL1 1 2 1 Applicable Controller AZ E5AZ E5EZ 2 Function 01 RS 232C communications 03 RS 485 communications B Two event inputs Functions a Power supply Alarm Mountin R Size voltage Input type output C
16. level 3 Default 20 ms Immunity Surge Bore Caan oe ee oT Note The baud rate data length stop bits and vertical parity can be 2 kV line to ground individually set using the Communications Setting Level Power line output line relay output 1 kV line to ground Input line Communication Immunity Voltage Dip Interrupting EN61000 4 11 0 5 cycle 100 rated voltage UL 61010C 1 Approved standards CSA C22 2 No 1010 1 EN61326 EN61010 1 IEC61010 1 Conformed standards VDE0106 Part 100 Finger protection when the terminal cover is mounted OMRON Current Transformer Order Separately Ratings Dielectric strength 1 000 VAC for 1 min Vibration 5 resistance 20 2 AG mis Weight E54 CT1 Approx 11 5 g E54 CT3 Approx 50 g Accessories Armatures 2 E54 CT3 only Plugs 2 Heater Burnout and Heater Short Alarms Maximum heater current 50 A AC Input current indication accuracy 5 FS 1 digit max 0 1 to 49 9 A in units of 0 1 A 0 0 A Heater burnout Heater short alarm output turns OFF 50 0 A Heater burnout Heater short alarm output turns ON Minimum detection ON time 190 ms See note 1 Heater burn out alarm set ting range 0 1 to 49 9 A in units of 0 1 A 0 0 A Heater burnout Heater short alarm output turns ON 50 0 A Heater burnout Heater short alarm output turns OFF Minimum detection OFF time 190 ms See note 2 Note 1 Ifthe ON time of c
17. 1 output turns ON whenever an input error occurs An error message is displayed when the PV or PV SV valve open percentage is displayed Note When the manual MV MV at stop or MV at PV error is set the control output corresponds to the set value Display Range Exceeded Meaning Though this is not an error it is displayed if the process value exceeds the dis play range when the control range is larger than the display range The display ranges are shown below e When less than 1 999 199 9 cece e When more than 9 999 999 9 33323 Operation at Error Control continues allowing normal operation The message is displayed when the PV or PV SV valve open percentage is displayed OMRON E5EZ PRR Platinum resistance thermometer input Except for models with Platinum resistance thermometer input Except for models with a setting range of 199 9 to 500 0 C a setting range of 199 9 to 500 0 C Thermocouple input Except for models with a setting range of Thermocouple input Except for models with a setting range of 199 9 to 400 0 C 199 9 to 400 0 C ES1B fe range 7 ae Control range oF 5e rr display Numeric display 5 6rr display rr display cecce display Numeric display 5 r r display Analog current voltage Input Analog Input e When display range lt control range e When display range gt control range Control range Pe range 5 rr display ccce display Numeric display a333 display 5
18. B ee a 11 Analog Input TC Pt Nomenclature E5EZ PRR Event Input RS232C RS485 a 12 sD 42 Bo 24 B 14 14 sG AA DO NOT Alarm Output 2 Alarm Output 1 BOS Temperature Unit The temperature unit is displayed when parameters are set to display a temperature The display is determined by the currently selected temperature unit parameter set value indicates C and indicates F Operation Indicators 1 ALM1 alarm 1 Lights when alarm 1 output is ON ALM2 alarm 2 Lights when alarm 2 output is ON 2 OUT1 OUT2 control output 1 control output 2 Lights when control output 1 or control output 2 is ON 3 STOP Stop Lights when operation is stopped During operation this indicator lights when operation is stopped by an event or by using the RUN STOP function 4 CMW Communications Writing Control Lights when communications writing is enabled and is not lit when it is disabled 5 MANU Manual Mode Lights when the auto manual mode is set to manual mode Mode Key Press this key to change parameters within a setting level Level Key Press this key to move between setting levels The setting level is selected in the following order operation level adjustment level initial setting level communications setting level No 1 Display Displays the process value or parameter type Lights for approximat
19. CD ROM driver Never attempt to play the disk in a gt R Accessory general purpose audio player a A 2 Do not connect or disconnect the Conversion Cable connector repeatedly over a short period of time The computer may a malfunction SS 3 After connecting the Conversion Cable to the computer check the R COM port number before starting communications The computer requires time to recognize the cable connection This delay does Terminal Cover not indicate failure E53 COV11 4 Do not connect the Conversion Cable through a USB hub Doing so may damage the Conversion Cable 5 Do not use an extension cable to extend the Conversion Cable length when connecting to the computer Doing so may damage the Conversion Cable 6 For models with communications the same port is used by the E5AZ Setting Tool port and for communications via the communications WaleIpieor PACRINY terminals Do not use communications via the communications VAcegssory terminals when using the Setting Too port 1 For waterproof mounting waterproof packing must be installed on Mounting the Controller Waterproofing is not possible when group mounting Controllers Waterproof packing is not necessary when there is no Mounting to the Panel need for the waterproof function E5CZ 2 Insert the E5AZ E5EZ into the square mounting hole in the panel thickness 1 to 8 mm Attach the Mounting Brackets provided with the product to the mounting grooves on the
20. LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know and observe all prohibitions of use applicable to this product NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Disclaimers PERFORMANCE DATA Performance dat
21. adjusted by changing the Move to protect level Changes are effective after cycling power or time setting after a software reset Set either of these parameters 2 point shift Lower limit temperature n input shift value Operation adjustment protect Restricts displaying and Protocol setting BY RAPE modifyi 7 i Switches between CompoWay F E OMN E modifying menus in operation witches between Compovvay Ege p adjustment and manual SYSWAY and Modbus control levels g Communications Unit No Initial setting communications TII protect LLI L This protect level restricts He I movement to the initial setting communications setting and advanced function setting levels Communications baud rate CompoWay F SYSWAY only Setting change protect Protects changes to setups by operating the front panel keys ommunications v ata length Communications stop bits Communications parity Send data wait time OMRON E5 Z Press the O Key for at least 1 s Press the O Key less than 1 s Input type Auto manual select addition Additional PV display OE MT S LNLE Parameter initialization S
22. ange 1500 by scaling ae 1999 to 9999 or at 199 9 to 999 9 1100 1000 2 900 850 800 D 700 a eoo sono sono a a Ge 400 F400 300 260 200 a 100 0 KEK 5 140 0 F 60 o 0 0 0 0 0 ii Bae 1 TE 20 a __ _ 3 200 200 199 9 Setting number o 2 3 4 EW 6 7 8 9 22 10 11 12 23 The applicable standards for each of the above input ranges are as follows K J T E N R S B JIS C1602 1995 IEC 584 1 L Fe CuNi DIN 43710 1985 U Cu CuNi DIN 43710 1985 JPt100 JIS C 1604 1989 JIS C 1606 1989 Pt100 JIS C 1604 1997 IEC 751 Models with Analog Inputs p Current mA Voltage V arameters 4 to 20 0 to 20 1to5 Oto5 0 to 10 Set value 0 1 2 3 4 Minimum Setting Unit Set Value Alarm Scaling according to the location of the decimal point indicates factory settings Optional Functions Type Performance RS 232C Baud Rate 1200 2400 4800 9600 19200bps RS 485 Event Input ON Maximum of 1 KQ OFF Minimum of 100 KQ OMRON Specifications Ratings Power supply voltage E5EZ PRR 100 to 240 VAC 50 60 Hz Operating voltage range Power consumption 85 to 110 of rated supply voltage 10 VA 10 W Sensor input Temperature input type Thermocouple K J T E L U N R S B Platinum resistance thermometer Pt100 JPt100 Infrared temperature sensor 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C Voltage input 0 to 50 mV
23. e Places subject to vibration and large shocks 2 Use and store the product within the rated ambient temperature and humidity Gang mounting two or more Temperature Controllers or mounting Temperature Controllers above each other may cause heat to build up inside the Temperature Controllers which will shorten their service life In such a case use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers 3 To allow heat to escape do not block the area around the product Do not block the ventilation holes on the product 4 Be sure to wire properly with correct polarity of terminals 5 Use the specified size M3 5 width 7 2 mm or less crimped terminals for wiring To connect bare wires to the terminal block use stranded or solid copper wires with a gage of AWG24 to AWG 14 equal to a cross sectional area of 0 205 to 2 081 mm The stripping length is 5 to 6 mm Up to two wires of the same size and type or two crimp terminals can be inserted into a single terminal 6 Do not wire the terminals that are not used 7 To avoid inductive noise keep the wiring for the product s terminal block away from power cables carry high voltages or large currents Also do not wire power lines together with or parallel to product wiring Using shielded cables and using separate conduits or ducts is recommended Attach a surge suppressor or noise filter to peripheral devices that generate noise in par
24. gag 18 119 20 21 22 23 Shaded settings are the default settings Shaded settings are the default settings Alarm Types Select alarm types out of the 12 alarm types listed in the following table Sd Alarm output operation sale Alarm type When X is posi When X is nega tive tive 0 ata function Output OFF 1 _ gt L H See ta AnG ower a See note 2 note 1 id xX e 2 Upper limit pad B _ X 3 Lower limit eae Ii lt Upper and lower See note 3 note 1 limit range 5 Upper and lower on 4 See limit with standby OFF m i See note 4 note 1 Sequence See note 5 6 Upper limit with standby sequence 7 Lower limit with standby sequence 8 Absolute value ON mam ON mami Sama upper limit ore one 0 9 Absolute value ON lt gt ON ais lower limit eG cal 0 Absolute value PERVIENE PEE are 10 upper limit with pau ppi standby sequence j j Absolute value PEETER va ae 11 lower limit with i standby sequence le LBA for alarm 1 588 type only E note 6 E5CZ E5CZ U Note 1 With set values 1 4 and 5 the upper and lower limit values 2 3 6 Case 1 can be set independently for each alarm type and are expressed as L and H Set value 1 Upper and lower limit alarm Case 2 Case 3 Always ON H lt 0 L lt 0 L H SP SPL H H SP L H lt 0 L gt 0 H gt 0 L lt 0 o IHI lt L IH gt L 7 H gt
25. i i 3 mm dia distance of 30 mm ES1 LP3 For use with medium 0 to 500 temperatures 8 mm dia distance of 100 mm ES1 LP10 Note 1 At the time of shipment the ES1 PRO model s range will have to be changed for 0 to 500 C 50 C 2 This value is based on the energy restriction of 90 The actual item must be at least 1 5 times larger Note For more detailed information please refer to other ES1 L related materials E52 Series of Temperature Sensors Providing a diverse array of high accuracy temperature sensors e Used as a sensor for temperature controllers e Guaranteed that clients will be able to easily select the right model according to their temperature location and ambient operating conditions e Able to provide numerous models of various different categories cases lengths and terminal shapes e Able to provide low cost made to order models as well as models for universal use Note For more detailed information please refer to other E52 related materials OMRON Safety Precautions AN oF ATON Do not touch the terminals while power is being supplied Doing so may occasionally result in minor injury due to electric shock Operate the Temperature Controller properly Improper operation may cause minor or moderate injury or property damage Do not allow pieces of metal wire clippings or fine metallic shavings or filings from installation to enter the product Doing so may occasionally resul
26. keep the wiring for the Temperature Controller s terminal block away from power cables carrying high voltages or large currents Also do not wire power lines together with or parallel to Temperature Controller wiring Using shielded cables and using separate conduits or ducts is recommended Attach a surge suppressor or noise filter to peripheral devices that generate noise in particular motors transformers solenoids magnetic coils or other equipment that have an inductance component When a noise filter is used at the power supply first check the voltage or current and attach the noise filter as close as possible to the temperature controller Allow as much space as possible between the Temperature Controller and devices that generate powerful high frequencies high frequency welders high frequency sewing machines etc or surge 9 To reduce the risk of fire or electric shock install the Temperature Controller in a controlled environment relatively free of contaminants 10 The outputs may turn OFF when shifting to certain levels Take this into consideration when performing control 11 When turning OFF the power use a switch or relay to ensure the voltage decreases immediately Incorrect operation and data storage errors may occur if the voltage decreases slowly 12 Make sure that any Option Units are installed correctly Do not remove the internal PCB when installing an Option Unit 13 When inserting the Temperature Controlle
27. need to be attached if a waterproof structure UNIT LABEL a is not required E53 COV11 Two Covers provided Order Separately N oO 7 COM gt PC lt O0C0O00Q00 amp OCOOCCOOE LOC ch J e Y92S L1 Type Current Transformers Order Separately E54 CT1 lt 21 E54 CT3 ee E54 CT3 Accessory Connection Example i Armature Anmatire Approx 3 dia r i Two M3 depth 4 Plug J Approx 6 dia wo 22 m OMRON E5 IZ Operation Setting Levels Diagram This diagram shows all of the setting levels To move to the advanced function setting level you must enter passwords Some parameters are not displayed depending on the protect level setting and the conditions of use Control stops when you move from the operation level to the initial setting level Started in manual mode Started in automatic mode Press the LO Key for at least 1 s Operation Level Adjustment Level Press the O ce keys display Press the O will flash ce Keys for at least 1 s Press the O Key for at least 1 s display will flash Press the O Key for at RAES Control stops Press the C Key fo
28. not specified The indication accuracy of the R and S thermocouples at a temperature of 200 C max is 3 C 1 digit max 2 For E5EZ PRRILJ03 model products in order to satisfy the conduction and emission specifications of EN61326CLASSA a magnetic ring TDK ZAT1730 0730 should be added to the communications line between the K3SC unit and the controller OMRON Dimensions Note All units are in millimeters unless otherwise indicated 7 WOAR j WAN AY k Y Package Content e 1 Temperature Gauge e 2 Metallic Components For Installation 1 Operating Manual Eg e 1 Quality Certificate Z 96 During removal please use a screwdriver to remove the clips on the top and bottom of the front covering panel and then 2 I remove the temperature gauge s front GD panel 78 m N 1 i T j L ll e A 4 91 112 L f Il Il BPRPPPPPPRIA Accessories Unit Labels Order Separately Y92S L1 Type UNIT LABEL E5EZ PRR Panel Cutout Mounted Separately Group Mounted 45406 48 x n
29. pressing the 4 key for 1 second or more will switch to automatic mode switch to the operation level display the de fault in the level and allow manual operation of MV in this mode To access this level press the O key for 3 or more seconds in the operation level or adjustment level 1 second later the PV dis play will blink This level is used to indicate input type and select control method control period direct reverse operation and alarm type You can move to the advanced function setting level or communications setting level from this level Press the O key for at least 1 second to switch to the operation level Press the O key less than 1 second to switch to the communications level To activate this level set the parameters in the initial setting communications protect under the protect level to O and then enter the password 169 in the initial setting level The initial setting level can be accessed from this level This level is for setting the automatic display return time MV lim iter event input assignment standby sequence alarm hystere sis and ST self tuning To select this level press the O key less than one second in the initial setting level When the communications function is used set the communications conditions in this level Communicating with a personal computer host computer allows set points to be read a
30. providing forced cooling however be careful not to cool down the terminals sections alone to avoid measurement errors Measurement Accuracy 1 When extending or connecting the thermocouple lead wire be sure to use Compensating wires that match the thermocouple types 2 When extending or connecting the lead wire of the platinum resistance thermometer be sure to use wires that have low resistance and keep the resistance of the three lead wires the same 3 Mount the product so that it is horizontally level 4 If the measurement accuracy is low check to see if input shift has been set correctly Operating Precautions 1 Ittakes approximately two seconds for the outputs to turn ON from after the power supply is turned ON Due consideration must be given to this time when incorporating Temperature Controllers ina sequence circuit 2 When using self tuning turn ON power for the load e g heater at the same time as or before supplying power to the Temperature Controller If power is turned ON for the Temperature Controller before turning ON power for the load self tuning will not be performed properly and optimum control will not be achieved 3 When starting operation after the Temperature Controller has warmed up turn OFF the power and then turn it ON again at the same time as turning ON power for the load Instead of turning the Temperature Controller OFF and ON again switching from STOP mode to RUN mode can also be used
31. r display 5eirr display Numeric display 5 r r display 1999 lt q Display range gt 9999 1999 lt Display range 9999 199 9 999 9 199 9 999 9 Meaning Internal memory operation is in error Action First turn the power OFF then back ON again If the display remains the same the Controller must be repaired If the display is restored then the probable cause Is electrical noise affecting the control system Check for electrical noise Operation at Error Control output and alarm output turn OFF Potentiometer Input Error Meaning Valve opening has exceeded its regular range of 10 to 110 Action Check to see if there have been any wiring errors burnouts or short circuits in the potentiometer If there are no problems with the wiring you can restart the power supply If the display remains the same the Controller must be replaced If the display is re stored then the probable cause is interference which should be avoided Operation at Error Control output will output MV based on the MV during error setting position Alarm output will operate as normal Motor Calibration Error Meaning Motor calibration did not completely finish Action After confirming the potentiometer and the wiring of the motor driving valve per form motor calibration again Operation at Error Control output and alarm output set to OFF OMRON E5EZ PRR Position proportional control of a c
32. segment displays e Setting protection indicator informs operator when protection is enabled e Manual output provided e New protocol called Modbus is installed in the models with communications e USB Serial conversion cable is available Note Refer to Precautions on page 33 Main I O Functions Event Inputs e None Sensor Inputs e Universal thermocouple Pt inputs E Models with temperature inputs e Analog current voltage inputs Models with analog inputs Indication Accuracy Control Output 1 E5CZ e Relay output e Thermocouple input 0 5 of PV e Pt input 0 5 of PV e Analog input 0 5 FS E5CZ U e Thermocouple input 1 of PV e Pt input 0 5 of PV Sampling Period e 250 ms e Two paces 2 level Display PV and SV 4 digit Display CAd us 48 x 48 mm E5CZ 48 x 48 mm E5CZ U NEW Note Refer to page 30 for information on changes in comparison to previous models e Auto manual switching e Models also available with RS 485 e Two communications Alarm Outputs e Voltage output for driving SSR e Current output r ae 7 This data sheet is provided as a guideline for selecting products Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product E5CZ E5CZ U ESAZ E5EZ Digital Temperature Controllers User s Manual Cat No H207 E5CZ E5CZ U E5AZ E5EZ Digital Temperatu
33. taking the Temperature Controller apart for disposal Sharp parts inside the Temperature Controller may Cause injury 22 Check the orientation of the connectors on the Conversion Cable before connecting the Conversion Cable Do not force a connector if it does not connect smoothly Using excessive force may damage the connector 23 Do not place heavy object on the Conversion Cable bend the cable past its natural bending radius or pull on the cable with undue force 24 Do not connect or disconnect the Conversion Cable while communications are in progress Product faults or malfunction may occur 25 Make sure that the Conversion Cable s metal components are not touching the external power terminals 26 Do not touch the connectors on the Conversion Cable with wet hands Electrical shock may result Precautions for Correct Use Service Life 1 Use the product within the following temperature and humidity ranges Temperature 10 to 55 C with no icing or condensation Humidity 25 to 85 If the product is installed inside a control board the ambient temperature must be kept to under 55 C including the temperature around the product 2 The service life of electronic devices like Temperature Controllers is determined not only by the number of times the relay is switched but also by the service life of internal electronic components Component service life is affected by the ambient temperature the higher the temperature the
34. the edge of the front panel when handling it 26 Do not use paint thinner or similar chemical to clean with Use standard grade alcohol 27 Use tools when separating parts for disposal Contact with the sharp internal parts may cause injury OMRON Precautions for Correct Use Service Life 1 Use the product within the following temperature and humidity ranges Temperature 10 to 55 C with no icing or condensation Humidity 25 to 85 If the product is installed inside a control board the ambient temperature must be kept to under 55 C including the temperature around the product 2 The service life of electronic devices like Temperature Controllers is determined not only by the number of times the relay is switched but also by the service life of internal electronic components Component service life is affected by the ambient temperature the higher the temperature the shorter the service life and the lower the temperature the longer the service life Therefore the service life can be extended by lowering the temperature of the Temperature Controller 3 When two or more Temperature Controllers are mounted horizontally close to each other or vertically next to one another the internal temperature will increase due to heat radiated by the Temperature Controllers and the service life will decrease In such a case use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers When
35. this level simultaneously press the O and ce keys for at least 3 seconds This level is to prevent unwanted or acciden tal modification of parameters Protected levels will not be dis played and so the parameters in that level cannot be modified This level is displayed when you turn the power ON You can move to the protect level initial setting level manual control level and adjustment level from this level Normally select this level during operation During operation the process value and manipulated variable can be monitored and the set points alarm values and upper and lower limit alarms can be monitored and modified To select this level press the O key for less than one second This level is for entering set values and offset values for control This level contains parameters for setting the AT auto tuning communications writing enable disable hysteresis multi SP in put shift values heater burnout alarm HBA and PID constants You can move to the top parameter of the operation level initial setting level and protect level from here Pressing the 4 key under the operation adjustment level for 1 second or more will activate manual mode and switch to the manual control level Under manual control only process value set value valve open percentage manual MV can be displayed Under the process value set value valve open percentage manual MV manual control level
36. top and bottom surfaces of the rear case 3 Use a ratchet to alternately tighten the screws on the top and bottom Mounting Brackets little by little to maintain balance until the ratchet turns freely Order the P2CF 11 or P3GA 11 Socket separately Terminal Cover E53 COV17 order separately Adapter order separately Mounting the Terminal Cover For the E5CZ make sure the UP characters on the Cover are in the correct position and insert the Cover into the holes at the top and bottom For the E5EZ or E5AZ fit the E538 COV11 Terminal Cover over the upper hook Mount it in the direction shown in the above diagram If the Terminal Cover is mounted in the opposite direction proper mounting of the fixtures may not be possible For Front mounting Socket Panel mounting is also possible Waterproof packing Accessory Panel 1 For waterproof mounting waterproof packing must be installed on the Controller Waterproofing is not possible when group mounting Controllers Waterproof packing is not necessary when there is no need for the waterproof function There is no waterproof function for the E5CZ U 2 Insert the E5CZ E5CZ U into the mounting hole in the panel 3 Push the adapter from the terminals up to the panel and temporarily fasten the E5CZ E5CZ U 4 Tighten the two fastening screws on the adapter Alternately tighten the two screws little by little to maintain a balance Tighten the screws to a
37. torque of 0 29 to 0 39 N m OMRON E5 IZ Removing the Temperature Controller from the Case E5CZ EZ AZ The Temperature Controller can be removed from the case to perform maintenance without removing the terminal leads This is possible for only the E5CZ E5AZ and E5EZ and not for the E5CZ U Check the specifications of the case and Temperature Controller before removing the Temperature Controller from the case Flat blade screwdriver SS Unit mm Y 4 ly Me h i Vy 7 YY E5EZ E5AZ 1 Insert a flat blade screwdriver into the two tool insertion holes one on the top and one on the bottom to release the hooks 2 Insert the flat blade screwdriver in the gap between the front panel and rear case and pull out the front panel slightly Hold the top and bottom of the front panel and carefully pull it out toward you without applying unnecessary force 3 When inserting the E5CZ EZ AZ check to make sure that the sealing rubber is in place and push the E5CZ EZ AZ toward the rear case until it snaps into position While pushing the E5CZ EZ AZ into place push down on the hooks on the top and bottom surfaces of the rear case so that the hooks are securely locked in place Be sure that electronic components do not come into contact with the case Precautions when Wiring e Separate input leads and power lines in order to prevent ex
38. value Press the A key to set the value to 10 Adjustment Settings for position proportional control Closed Floating Motor calibration and travel time Position proportional dead band and Open Close hysteresis PV dead band Operation at potentiometer input error E5EZ PRR To adjust the PID constants run AT When position proportional control is selected Closed Floating Motor calibra tion Travel time Position proportional dead band Open Close hysteresis Operation at potentiometer input error and PV dead bana can be used e Closed control Control whereby a potentiometer is connected to feed back the amount of opening of the valve e Floating control Control without feedback of the amount of opening of the valve Control is possible without connecting a potentiometer Run Motor calibration when a potentiometer is connected for closed control or floating control that monitors the amount of valve opening This will also automatically set the Travel time which is the amount of time from when the valve is completely open to when the valve is completely closed When performing floating control without a potentiometer it is necessary to man ually set the Travel time Set the travel time to the amount of time from when the valve is completely open to when the valve is completely closed The valve output hold interval the duration of ON OFF switching of open output and closed out
39. 0 L lt 0 SPH L IH lt IL Set value 4 Upper and lower limit range Case 1 Case 2 Case 3 Always ON H lt 0 L lt 0 L H SP SPL H H SP L H lt 0 L gt 0 H gt 0 L lt 0 E 2 H lt L H gt L H LSP H H gt 0 L lt 0 SPH L H lt L Set value 5 Upper and lower limit with standby sequence For Upper and Lower Limit Alarm Described Above e Case 1 and 2 Always OFF when the upper limit and lower limit hysteresis overlaps e Case 3 Always OFF Set value 5 Upper and lower limit with standby sequence Always OFF when the upper limit and lower limit hysteresis overlaps Set value 12 LBA loop break alarm can be set only for alarm 1 type Set the alarm types for alarms 1 to 3 independently in the initial setting level The default setting is 2 upper limit OMRON E5CZ E5CZ U Characteristics Note 1 The indication accuracy of K thermocouples in the 200 to D EC 1300 C range T and N thermocouples at a temperature of Thermocouple See note 1 100 C max and U and L thermocouples at any POU E aot of Dienaar temperature is 2 C 1 digit maximum The indication E5CZ U 1 of indicated value or 2 C whichever is accuracy of the B thermocouple at a temperature of 400 C Indication accuracy Sct eed a max is not specified The indication accuracy of the R and 0 5 of indicated value or 1 C whichever S thermocouples at a temperature of 200 C max is 3 C 1 _ is greater 1 digit max digit
40. 0 A AC Maximum heater E5OZ A3 with E53 AZM and E53 AZH current ESAZ EZ E5OZ R3 with E53 AZM and E53 AZH E50OZ O3HMO0O E5LIZ Q3 with E53 AZM and E53 AZH Single phase 50 A AC Single phase 50 A AC Heater short alarm Heater short alarm OMRON Precautions CAUTION Do not touch the terminals while power is being supplied Doing so may occasionally result in minor injury due to electric shock Do not allow pieces of metal wire clippings or fine metallic shavings or filings from installation to enter the product Doing so may occasionally result in electric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise minor injury from explosion may occasionally occur Do not leave the conversion cable connected to the product Malfunction may occur due to noise in the cable Do not use the Temperature Controller or Conversion Cable if it is damaged Doing so may occasionally result in minor electric shock or fire Never disassemble modify or repair the product or touch any of the internal parts Minor electric shock fire or malfunction may occasionally occur CAUTION Risk of Fire and Electric Shock a This product is UL recognized as Open Type Process Control Equipment It must be mounted in an enclosure that does not allow fire to escape externally b More than one disconnect switch may be required to de energize the equipment before servicing the produc
41. 200120 China specifications are subject to change without notice Tel 31 2356 81 300 Fax 31 2356 81 388 Tel 86 21 5037 2222 Fax 86 21 5037 2200 Printed in Japan OMRON Industrial Automation Global www ia omron com Cat No H209 E1 03 0909
42. 3 Alarm output Do not use l Relay output i 250 VAC 2A i Resistive load l Do not use Alarm output 2 l I eA 2A OQAOA HHO A Pt 7 l A TC B A Alarm output 1 Z HB alarm HS 1 y or lt a n T ed aF TC Pt universal input Analog input Nomenclature E5AZ E5EZ Temperature unit mae empera Operation indicators OMRON OMRON No 1 display eee E A ae li aa No 2 display z outi D ARRRS Operation indicators j No 2 display Level Key S OG Up Key Mode Key kl BIE Mode Key Down Key OMRON E5AZ E5EZ Dimensions E5AZ ied se p i p Sa se S nied So Ss Sa Waterproof Packing Mounting Bracket Accessory Accessory 11 2 a aa ES a eS a aa ES Waterproof Packing Mounting Bracket Geen 1 Accessory Accessory Crimp terminal size M3 5 Panel Cutout Individual Mounting Group Mounting 96 x number of units 3 5 8 9208 Note To remove the Controller from the case loosen the sc
43. 50 VAC 5 A resistive load Electrical life 100 000 operations Electrical life 100 000 operations E5EZ RULIL E5EZ RUO OUOLI SPST NO 250 VAC 5 A resistive load SPST NO 250 VAC 5 A resistive load Electrical life 100 000 operations Electrical life 100 000 operations E5CZ QUULI E5CZ QULULLI 12 VDC 15 PNP 12 VDC 15 PNP Max load current 21 mA Max load current 21 mA With short circuit protection With short circuit protection E5C0Z QUULIU l 12 VDC 15 PNP No models with plug in type Max load current 21 mA Control With short circuit protection output E5AZ Q000 E5AZ QU0000 12 VDC 15 20 PNP 12 VDC 15 20 PNP Max load current 40 mA Max load current 40 mA With short circuit protection With short circuit protection E5EZ QULILI E5EZ QUUOULI 12 VDC 15 20 PNP 12 VDC 15 20 PNP Max load current 40 mA Max load current 40 mA With short circuit protection With short circuit protection E5CZ CULLI E5CZ COULLI 4 to 20 mA DC 4 to 20 mA DC or 0 to 20 mA DC Load 600 Q max Load 600 Q max Resolution Approx 2 600 Resolution Approx 2 700 E5AZ CLILILI E5AZ CLILILIL Current 4 to 20 mA DC 4 to 20 mA DC or 0 to 20 mA DC Load 600 Q max Load 600 Q max Resolution Approx 2 600 Resolution Approx 2 700 E5EZ CLILILI E5EZ CULULLI 4 to 20 mA DC 4 to 20 mA DC or 0 to 20 mA DC Load 600 Q max Load 600 Q max Resolution Approx 2 600 Resolution Approx 2 700 11 segment digital display and single LE
44. 9 9 to 700 0 F N 13 200 to 1300 C 300 to 2300 F R 14 O to 1700 C 0 to 3000 F S 15 0 to 1700 C 0 to 3000 F B 16 100 to 1800 C 300 to 3200 F ntara 10 C to 70 C 17 0 to 90 C O to 190 F temperature 60 C to 120 C 18 0 to 120 C 0 to 240 F sensor 115 C to 165 C 19 0 to 165 C 0 to 320 F Sone 140 C to 260 C 20 0 to 260 C 0 to 500 F Analog Input 0 to 50 mV 21 Either of the following ranges by scaling 1999 to 9999 or 199 9 to 999 9 The default is 5 input Temperature setting range Current 4 to 20 mA Tet Use the following scales based on the Input 0 to 20 mA range of measurements Analog Input 2 1999 to 9999 Type 199 9 to 999 9 Oto5V 19 99 to 99 99 0to 10 V 1 999 to 9 999 The default is 0 OMRON E5EZ PRR Alarm Types e Alarm outputs are determined by a combination of alarm type 33 Gc alarm value and alarm hysteresis alarm output conditions e This section describes the alarm type alarm value upper limit alarm and lower limit alarm parameters 1 Al Set Type Alarm output operation are arm i values yp When X is positive When X is negative Type 2 0 Alarm function OFF Output OFF Tai 1 fu d lower limi TEE LLL See note 1 UPper and lower limit OFF m See note 2 O0ddA E ON Xe ON 7 PGS Upper limit OFF OFF o ON X le ON oly te 3 Lowe
45. D indicator E5CZ CZ U 7 segment digital display and single LED indicators Improved visibility Display A 7 segment digital display also possible method 11 segment digital display and single LED indicator E5AZ EZ 7 segment digital display and single LED indicators Improved visibility A 7 segment digital display also possible E5LZ COLULI Allocated to current output Transfer output No models with transfer outputs 4 to 20 mA DC or 0 to 20 mA DC Load 600 Q max Resolution Approx 2 700 4 to 20 mA DC OMRON E5 IZ Other Functions Item Previous models Improved models Display Display character switch 7 segment 11 segment Input Temperature input shift 1 point shift for temperature input Temperature input shift 2 point shift also possible for 2 point shift for no contact sensor input temperature input Manual outputs a Loop break alarm Control Control period 1 to 99 s Control period 0 5 or 1 to 99 s Alarm Alarm delays Characteristics fem improved models Sampling period Ee T Communications Specifications Item Previous models Improved models Communications protocols CompoWay F SYSWAY CompoWay F SYSWAY Modbus Baud rate 1200 2400 4800 9600 19200 bps 1200 2400 4800 9600 19200 38400 bps Heater Burnout Heater Short Alarm Characteristics Item Lo Previous models Improved models E5CZ E5CZ LI2MU with E53 CNHLIN E5CZ O0O2MO0 with E53 CZHO Single phase 50 A AC Single phase 5
46. Wiring Socket Order Separately Front connecting Socket P2CF 11 Terminal Layout Internal Connections Top View Eleven M3 5 x 7 5 sems screws Mounting Holes Two 4 5 dia mounting holes 70 max fK 40 0 2 Note Can also be mounted to a DIN track BS Note A model with finger protection P2CF 11 E is also available Back connecting Socket P3GA 11 Terminal Layout Internal Connections Bottom View Note 1 Using any other sockets will adversely affect accuracy Use only the specified sockets 2 A Protective Cover for finger protection Y92A 48G is also available OMRON Digital Temperature Controllers E5SAZ E5 A 96 x 96 mm and 48 x 96 mm These Best selling General CE N purpose Temperature Controllers Z m pm p Are Now Even Better a LL AT e Controllers now available with analog inputs e Faster sampling at 250 ms e Transfer output provided for easy output to recorders e Models available with a loop break alarm LBA and heater short alarm HS alarm e Manual output provided e Easy setting with 11 segment displays e New protocol called Modbus is installed in the NEW models with communications 96 x 96 mm 48 x 96 mm e USB Serial conversion cable is available E5AZ E5EZ Note Refer to Precautions on page 33 Note Refer to page 30 for information on changes in comparison to previous models Main I O Functions E5AZ E5EZ Event Inputs
47. a given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty and Limitations of Liability CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons Consult with your OMRON representative at any time to confirm actual specifications of purchased product DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown OMRON Corporation OMRON ELECTRONICS LLC kui Industrial Automation Company E ane Schaumburg pumOnee aero Control Devices Division H Q 3 es Industrial Component Division Tel 1 847 843 7900 Fax 1 847 843 7787 2 2 1 Nishikusatsu Kusatsu shi Shiga 525 0035 Japan OMRON ASIA PACIFIC PTE LTD Tel 81 77 565 5160 Fax 81 77 565 5569 No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 301 1 Fax 65 6835 2711 Regional Headquarters OMRON CHINA CO LTD OMRON EUROPE B V Room 2211 Bank of China Tower OMRON Corporation 2009 All Rights Reserved Wegalaan 67 69 2132 JD Hoofddorp 200 Yin Cheng Zhong Road In the interest of product improvement The Netherlands PuDong New Area Shanghai
48. ar case IP20 Terminals IP00 E5 Z Precautions for Operation ESEZ ESAZ 1 It takes approximately 2 seconds for the outputs to turn ON from Backer after the power supply is turned ON Due consideration must be ri Accessory given to this time when incorporating Temperature Controllers in a A Panel sequence circuit 2 When using self tuning turn ON power for the load e g heater A b at the same time as or before supplying power to the Temperature A Controller If power is turned ON for the Temperature Controller BS before turning ON power for the load self tuning will not be performed properly and optimum control will not be achieved Teimindi Covei 3 When starting operation after the Temperature Controller has E53 COV11 warmed up turn OFF the power and then turn it ON again at the order separately same time as turning ON power for the load Instead of turning the Temperature Controller OFF and ON again switching from STOP mode to RUN mode can also be used 4 Avoid using the Controller in places near a radio television set or wireless installing These devices can cause radio disturbances Waterproof packing ESEZ which adversely affect the performance of the Controller Accessory USB Serial Conversion Cable Ce iam 1 The disk that is included with the Conversion Cable is designed for a Bracket Panel a computer
49. ay output Relay output SPDT 250 VAC 3 A 250 VAC 1 A Resistive load Resistive load Control output 1 git force 4 Les Alarm output 2 Voltage output 12 VDC 21 mA i 3 O 1 D Input power supply A TC Pt 100 to 240 VAC universal input 24 VAC DC no polarity Note For the Wiring Socket purchase the P2CF 11 or PG3A 11 separately OMRON Nomenclature E5CZ E5CZ U The front panel is the same for the E5CZ and E5CZ U Temperature unit OM RON EN OM OM PY A GA GAYA c i up Oi ou S 7 JE S00 lt es Dimensions E5CZ Terminal Models Individual Mounting 58 IMIR AIi A Q 7 Waterproof Packing Accessory Mounting Adapter Accessory Terminal Cover E53 COV17 Order separately Note The terminal block cannot be removed E5CZ E5CZ U Panel Cutout Group Mounting 48 x number of units 2 5 5 o i E Waterproofing is not possible when group mounting Controllers ali 58 ih 60min y Waterproof Packing Accessory Mounting Adapter Accessory y 45 26 97 48 45 De _ Recommended panel thickness is 1 to 5mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof insert the water
50. ber of multi SP uses Select 2 or 4 Event input assignment 1 Input setting Multi SP RUN STOP Event input assignment 2 Multi SP uses an AFF Standby sequence reset Reset conditions after standby sequence is canceled Alarm 1 open in alarm ON OFF setting of alarm output 1 Alarm 1 hysteresis Alarm 2 open in alarm ON OFF setting of alarm output 2 Alarm 2 hysteresis a 2 PID parameters Input digital filter Set the time constant in units of s Additional PV display Displayed first in the operation level Automatic display return time Automatic return to operation level when the keys on the front panel are operated OMRON Initial setting level Alarm 1 latch Activate alarm latch Alarm 2 latch Move to protect level time Input error output Cold junction compensation method MB command logic switching Alarm 1 ON delay Alarm 2 ON delay Alarm ON OFF Alarm 1 dglaye OFF delay Alarm 2 OFF delay Additional MV for stop error Process value dead band Valve opening display Da Dapa ga Manual MV ee Limits in effect oOoOoow Scaling upper limit Scaling lower limit Decimal point Input type For analog in
51. blade screwdriver Unit mm A Y al E5EZ PRR Precautions when Wiring e Separate input leads and power lines in order to prevent external noise e Use wires with a gage of AWG24 cross sectional area 0 205 mm to AWG14 cross sectional area 2 081 mm twisted pair cable stripping length 5 to 6 mm e Use crimp terminals when wiring the terminals e Tighten the terminal screws to a torque of 0 74 to 0 9 N m e Use the following types of crimp terminals for M3 5 screws o h 7 2 mm max S A e Do not remove the terminal block Doing so will result in malfunction or failure OMRON MEMO MEMO Warranty and Application Considerations Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranty and Limitations of Liability WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF
52. ble standards for the input types U Cu CuNi DIN 43710 1985 Shaded settings are the default settings are as follows Pt100 IEC 751 K J T E N R S B IEC 584 1 JPt100 JIS C 1604 1989 JIS C 1606 1989 L Fe CuNi DIN 43710 1985 Models with Analog Inputs 4 to 20mA 0to20mA 1to5V Usable in the following ranges by scaling 1999 to 9999 199 9 to 999 9 19 99 to 99 99 or 1 999 to 9 999 Input Type Voltage Input specification Setting range 0to 10 V Shaded settings are the default settings Setting number OMRON Alarm Types Select alarm types out of the 12 alarm types listed in the following table Set value 0 Alarm type Alarm function OFF Alarm output operation When X is posi When X is nega tive Output OFF tive See note 1 Upper and lower limit See note 2 X X 2 Upper limit au ae SP SP gt X 4 gt X lt lt 3 Lower limit ae 1 i 4 Upper and lower on TEE ale i note limit range GFP L See note 3 5 Upper and lower on 4 See note limit with standby OFF m i See note 4 1 sequence See note 5 Upper limit with ON gt A o PA i standby sequence OFF i OFF SP Lower limit with oN m ON X y standby sequence OFF n b SER O 8 Absolute value ON SA ON lt X upper limit or OEP 7 9 Absolut
53. caling upper limit MV display HS alarm use Number of multi SP uses I Two SPs 1 Four SPs 2 Scaling lower limit Automatic display return time I Event input HS alarm latch M assignment 1 Decimal point a None For input type of analog Alarm 1 latch Event input assignment 2 HS alarm hysteresis For input type of temperature Alarm 2 latch Multi SP uses 1 LBA detection time SP upper limit Limit the set point Alarm 3 latch LBA level SP lower limit Move to protect level LBA band time PID ON OFF TY i Input error output Standard or heating cooling uM Li Control output 1 assignment For input type of tem perature standard control or PID Cold junction compen sation m
54. del E5AZ Y92S P4 E5EZ Y92S P5 Current Transformers CTs Hole diameter Model 5 8 dia E54 CT1 12 0 dia E54 CT3 OMRON Specifications Ratings Power supply voltage Operating voltage range Power consumption ES5AZ E5EZ 100 to 240 VAC 50 60 Hz 85 to 110 of rated supply voltage 8 5 VA 24 VAC 50 60 Hz or 24 VDC 6 VA 24 VAC 4 W 24 VDC Sensor input Models with temperature inputs Thermocouple K J T E L U N R S or B Platinum resistance thermometer Pt100 or JPt100 Infrared temperature sensor 10 to 70 C 60 to 120 C 115 to 165 C or 140 to 260 C Voltage input 0 to 50 mV Models with analog inputs Current input 4 to 20 mA or 0 to 20 mA Voltage input 1 to 5 V O0 to 5 V or O to 10 V Input impedance Current input 150 Q Voltage input 1 MQ Use a 1 1 connection when connecting the ES2 HB SPST NO 250 VAC 5 A resistive load electrical life 100 000 operations minimum applicable load 5 V Relay output 10 mA Control Voltage output output for driving Output voltage 12 VDC 15 20 PNP max load current 40 mA with short circuit protection circuit SSR Current output 4 to 20 mA DC 0 to 20 mA DC load 600 Q max resolution approx 2 700 Alarm output SPST NO 250 VAC 2 A resistive load electrical life 100 000 operations minimum applicable load 5 V 10 mA Contact input ON 1 kQ max OFF 100 kQ min Non contact Event inp
55. e interior of the product and never touch nor apply shock to the terminals or electronic components When inserting the interior of the product do not allow the electronic components to touch the case 14 Do not use paint thinner or similar chemical to clean with Use standard grade alcohol 15 Design the system e g control panel considering the 2 seconds of delay that the product s output to be set after power ON 16 The output may turn OFF when shifting to certain levels Take this into consideration when performing control 17 The number of EEPROM write operations is limited Therefore use RAM write mode when frequently overwriting data during communications or other operations OMRON 18 Always touch a grounded piece of metal before touching the Temperature Controller to discharge static electricity from your body 19 Control output that is voltage output is not isolated from the internal circuits When using a grounded thermocouple do not connect any of the control output terminals to ground Doing so may result in an unwanted circuit path causing error in the measured temperature 20 When replacing the body of the Temperature Controller check the condition of the terminals If corroded terminals are used contact failure in the terminals may cause the temperature inside the Temperature Controller to increase possibly resulting in fire If the terminals are corroded replace the case as well 21 Use suitable tools when
56. e value ON Pore lower limit OFF Absolute value PEV 10 upper limit with a standby sequence Absolute value x 11 lower limit with ee standby sequence j 12 LBA for alarm 1 See note S type only Note 1 3 6 Case 1 E5AZ E5EZ With set values 1 4 and 5 the upper and lower limit values can be set independently for each alarm type and are expressed as L and H Set value 1 Upper and lower limit alarm Case 2 Case 3 Always ON H lt 0 L lt 0 L H SP SPL H H SP L H lt 0 L gt 0 H gt 0 L lt 0 1 Het IH lt IL IH gt L H gt 0 L lt 0 SPH L IH lt L Set value 4 Upper and lower limit range Case 1 Case 2 Case 3 Always ON H lt 0 L lt 0 L HSP SPL H H SP L H lt 0 L gt 0 H gt 0 L lt 0 CE E IH lt LI IH gt L H LSP JAY IL H gt 0 L lt 0 SPH L IH lt L Set value 5 Upper and lower limit with standby sequence For Upper and Lower Limit Alarm Described Above e Case 1 and 2 Always OFF when the upper limit and lower limit hysteresis overlaps e Case 3 Always OFF Set value 5 Upper and lower limit with standby sequence Always OFF when the upper limit and lower limit hysteresis overlaps Set value 12 LBA loop break alarm can be set only for alarm 1 type Set the alarm types for alarms 1 to 3 independently in the initial setting level The default setting is 2 upper limit OMRON ES5AZ E5EZ
57. ections in each screen can be changed by using the A and I keys row ro Typical Example 1 Setup Procedure Input Type 5K thermocouple 200 C to 1300 C Control Method PID Control Alarm 1 Type 2 upper limit deviation Operation level IZ ba al m R Alarm Value 1 20 C deviation Set value 100 C immm Process value set wuu value valve open cocoon _ percentage Press the Ol key for at least 3 seconds Initial setting level Initial setting level Check input type Input type 5 Set input specifications Check alarm type Set control specifications Set alarm type Press the key for at least 1 second Control starts Operation level bm Process value set value valve open percentage Use the A and keys to set the SP to 100 C a7 2 fn K Running Confirm that control is running Stopped 5 3 Operation level Set alarm values Alarm value 1 25 Use the Z and keys to set the alarm value to 20 C Start operation Start operation OMRON E5EZ PRR Typical Example 2 Input type 9T thermocouple 200 C to 400 C Control method PID contro
58. ed from USB host Models with thermocouple platinum resistance thermometer Power supply controller input universal input Proportional band P 0 1 to 999 9 EU in units of 0 1 EU See note 3 Power supply voltage 5 VDC Models with analog input 0 1 to 999 9 FS in units of 0 1 FS Current consumption 70 mA Integral time I 0 to 3999 s in units of 1 s Ambient operating temperature 0 to 55 C with no condensation or icing Derivative time D 0 to 3999 s in units of 1 s Ambient operating humidity 10 to 80 Control period 0 5 1 to 99 s in units of 1 s 20 to 60 C with no condensation or Manual reset value 0 0 to 100 0 in units of 0 1 Storage temperature icing Alarm setting range 1999 to 9999 decimal point position depends on input type Storage humidity 10 to 80 Sampling period 250 ms Altitude 2 000 m max Affect of signal source Thermocouple 0 1 C Q max 100 Q max See note 4 Weight Approx 100 g resistance Platinum resistance thermometer 0 4 C Q max 10 Q max Note A driver must be installed in the personal computer Refer to installation information in the operation manual for the 2 000 VAC 50 or 60 Hz for 1 min between terminals with Conversion Cable different charge l Insulation resistance 20 MQ min at 500 VDC Dielectric strength Vibration Malfunction 10 to 55 Hz 20 m s for 10 min each in X Y and Z directions Com mun ications S ecifications resis
59. ely one second during startup No 2 Display Displays the set point parameter operation read value or the variable input value Lights for approximately one second during startup No 3 Display Displays valve open percentage when valve opening display is on Nothing will be displayed when valve opening display is switched off Up Key Each press of this key increments the value displayed on the No 2 display or advances the setting Holding the key down speeds up the incrementation Automatic Manual Key Press this key for at least one second to switch between automatic and manual mode Down Key Each press of this key decrements values displayed on the No 2 display or reverses the setting Holding the key down speeds up the decrementation OMRON E5EZ PRR Operation Initial hardware setup including the sensor input type alarm types control periods and other settings is done using parameter displays The O and e keys are used to switch between parameters and the amount of time that you press the keys determines which parameter you move to Two typical examples are described as follows Explanation of Examples Changing Parameters wietebeteceuseonaa A image means that there are parameters Continue pressing the cel key to change parameters until you reach the intended parameter Changing Numbers Numeric data and sel
60. eramic kiln The control method whereby a potentiometer is used to read the amount of opening of a valve and then open or close the valve by means of an attached control motor is called position proportional control or on off servo control Application To control a gas kiln using a position proportional control valve select the control valve control type and configure the instrumentation as shown in the following example Temperature Input Analog Input Potentiometer SP ramp SP after change SP ramp set value SP ramp in units of time SP before change Point of change E5EZ PRR Temperature a Sensor gt Burner The SP ramp function allows limits to be placed on temperature changes which control the temperature within a specific range This is useful for ceramic kiln in which severe temperature changes may cause damage or corruption OMRON E5EZ PRR Wiring Settings Travel time we 12 s ration level Process value set value valve open percentage O ge D Xy gt or justment level SP ramp set value wn Ch OMRON Input should be connected to terminals 9 10 and 11 depending on input t
61. ethod Alarm output 1 assignment When assigning PID self tuning or control output to pulse output M Control period heating MB command logic Alarm 2 open in alarm e p switching IIL Mr Alarm output 2 wa assignment Lute Set the pulse output cycle Control period cooling Alarm 1 ON delay Alarm output 3 assignment E5AZ E5EZ only Alarm 2 hysteresis Alarm 3 open in alarm Character select Alarm 3 hysteresis E pai JA N Alarm 3 ON delay Alarm 2 type Alarm 1 OFF delay HB ON OFF Alarm 3 type Alarm 2 OFF delay Heater burnout latch Transfer output type Alarm 3 OFF delay HL H Heater burnout _ hysteresis I IIAL Linear output Transfer output upper limit ST stable range Input shift type
62. l Calculate PID constants by AT auto tuning Alarm 1 type 2 upper limit Set value 150 C Setup Procedure Power ON Initial setting level Set input specifications Set alarm type PV SP after AT is stopped The set point flashes during auto tuning AT execution Adjustment level After AT is stopped During AT Operation level execution Set alarm value Start operation OMRON Operation level Process value set value valve open percentage Press the O key for at least 3 seconds Control stops M C203 om 0 H z5 Hes Initial setting level Use the A and keys to select Inputtype 4 the input type Check the alarm type Alarm 1 type 2 Press the O key for at least 1 second Use the A E Process value and F keys to set value valve set the SP to open pe percentage 3 Press the O key for less than 1 second m C1 en m Lal Execute AT Cancel AT OFF Press the O key for less than 1 second Control starts Process value Confirm that set value the set point is valve open 150 C percentage Running Stopped Bear Confirm that control is running Use the A and X keys to se
63. layed Adjustment level and changed Initial Setting Communications Protect This protect level restricts movement to the initial setting level communications setting level and advanced function setting level Set value Initial setting level Communications setting level Advanced function setting level 0 Movement possible Movement possible Movement possible 1 Movement possible Movement possible Movement not possible 2 Movement not possible Movement not possible Movement not possible e The default is 1 Setting Change Protect This protect level restricts key operations Set value Description OFF Settings can be changed using key operations Settings cannot be changed using key operations The protect level settings however can be changed e The default is OFF Automatic Manual Key Protect This protect level restricts key operations Set value Description OFF Settings can be changed between automatic and manual mode using 4 key operations ON Settings cannot be changed between automatic and manual mode using 4 key operations The protect level settings however can be changed e The default is OFF Setting Communications Parameters e Each parameter is enabled when the power is reset e Match the communications specifications of the E5EZ PRR and the host computer If multiple devices are Communications setting level Communicatio
64. line RS 4 tinoj tance Destruction 300 m s min 3 times each in X Y and Z directions connection method 2489 multipoint E5CZ Controller Approx 150 g Mounting Bracket Approx Communications RS 485 two wire half duplex 5C 10g Weight Synchronization te E5CZ U oe Approx 110 g Mounting Bracket Approx method Start stop synchronization PpS Front panel IP66 indoor use Baud rate 1200 2400 4800 9600 19200 or 38400 bps Degree of Rear case IP20 Terminals IP00 Transmission code ASCII protection Front panel Equivalent to IP50 Rear case IP20 oe Terminals IP00 See note 4 Data length 7 or 8 bits p Haa Stop bits 1 or 2 bits Memory protection T aa memory number of writes 1 000 000 p Vertical parity none even odd Emission Enclosure EN55011 Group1 Class A Frame check sequence FCS with SYSWAY Emission AC Mains EN55011 Group1 Class A SOF CetecHon Block check character BCC with CompoWay F or Immunity ESD EN61000 4 2 4 kV contact discharge CRC 16 Modbus level 2 8 kV air discharge level 3 Flow control None Immunity RF interference EN61000 4 3 10 V m Interface RS 485 80 1000 MHz 1 4 2 0 GHz amplitude r modulated level 3 Retry function None 10 V m 900 MHz pulse modulated Communications Immunity Conducted Disturbance 40 bytes EMC EN61000 4 6 3 V buffer 0 15 to 80 MHz level 2 TIS mE Immunity Burst EN61000 4 4 2 kV Power line level 3 Send data wait time 1 kV I O signal line
65. max Analog input 0 5 FS 1 digit max 2 EU stands for Engineering Unit and is used as the unit CT input 5 FS 1 digit max after scaling For a temperature sensor the EU is C or F Influence of temperature R S and B thermocouple inputs o See note 2 1 of PV or 10 C whichever is greater 1 digit max 3 B R and S sensors 0 2 C Q max 100 Q2 max Other thermocouple inputs 4 There is no waterproof function for the E5CZ U 1 of PV or 4 C whichever is greater 1 digit max 10 C for 100 C or less for K sensors Influence of voltage Platinum resistance thermometer inputs USB Serial Conversion Cable See note 2 1 of PV or 2 C whichever is greater 1 digit max Analog inputs Applicable OS Windows 2000 XP Vista 41 of FS 1 digit max Applicable software Thermo Mini Models with thermocouple platinum resistance thermometer input universal input Applicable models E5CZ E5CZ U E5AZ E5EZ Hysteresis 0 1 to 999 9 EU in units of 0 1 EU T Models with analog input USB interface standard Conforms to USB Specification 1 1 0 01 to 99 99 FS in units of 0 01 FS DTE speed 38400 bps Models with thermocouple platinum resistance thermometer input universal input an Computer USB type A plug Proportional band P 0 1 to 999 9 EU in units of 0 1 EU Connector specifications Temperature Controller Setup Tool port Models with analog input
66. nd written and manipulated variables to be monitored E5EZ PRR Setting the Input Type The Controller supports four input types platinum resistance thermometer thermocouple infrared temperature sensor and analog inputs Set the input type that matches the sensor that is used In the product specifications there are models with thermocouple resistance thermometer inputs universal input and models with analog input The settings differ depending on the model Check to make sure which model you are using Input Types 5 List of Input Types Input Type Specifications Set value Input temperature setting range 0 200 to 850 C 300 to 1500 F Piatinun Pt100 1 199 9 to 500 0 C 199 9 to 900 0 F Resistance 2 0 0 to 100 0 C 0 0 to 210 0 F Thermometer 3 199 9 to 500 0 C 199 9 to 900 0 F u 4 0 0 to 100 0 C 0 0 to 210 0 F K 5 200 to 1300 C 300 to 2300 F 6 20 0 to 500 0 C 0 0 to 900 0 F J 7 100 to 850 C 100 to 1500 F 8 20 0 to 400 0 C 0 0 to 750 0 F T 9 200 to 400 C 300 to 700 F 22 199 9 to 400 0 C 199 9 to 700 0 F E 10 0 to 1100 F Thermocouple 0 to 600 C L 11 100 to 850 C 100 to 1500 F U 12 200 to 400 C 300 to 700 F 23 199 9 to 400 0 C 19
67. ng resistance 18 2 Q 100 g 100V oh gt LL 1L o S ia 5100 mV k 5 Q _ O _ 1a fh 10 SEH EEE HH 10 100 mA 1 10 1001 000 A Thru current lo A r m s E54 CT3 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0 8 Q Output voltage Eo V r m s 1 annuli le L 4 HEHH HHHH 10 ETH EHEC EC 1 10 100mA 1 10 1001 000 A Thru current lo A r m s OMRON E5AZ E5EZ External Connections e The voltage output for control output 1 is not electrically insulated from the internal circuits When using a grounding thermocouple do not connect any of the control output terminals to ground If the control output terminals are connected to ground errors will occur in the measured temperature values as a result of leakage current E5AZ E5EZ Option Units E53 AZB E53 AZ01 E53 AZ03 Event input RS 232C RS 485 100 to 240 VAC LDI aa Evi SD AD B 24 VAC DC no polarity Nput power supply L i Eyo as oo Relay output 250 VAC H JEVI EV2 D RD 4D A 5 A Resistive load Voltage output 3 i 3 SG 3 Do not use 12 VDC 40 mA Control output 1 Current output 4 to 20 mA DC 0 to 20 mA DC Load 600 Q max Alarm output
68. ns connected ensure that the communications specifications for all devices in the system except the Unit number Communications unit number are the same Parameters Symbol Set monitor values Settings Default Unit Communications 2 Baud rate Unit number U no 0 to 99 1 None a a od co ce pa Baud rate 1 2 2 4 4 8 9 6 19 2 17 al 9 6 Kbps Data length Data length 7 8 7 Length Stop bits 1 2 2 Bit Parity None even odd nank Eunka add Even None Stop bits E5EZ PRR Error Displays When an error occurs the error contents are shown on the No 1 display This section describes how to check error codes on the display and the actions to be taken to remedy the problems Input Error Meaning The input value has exceeded the input indication range 1999 199 9 to 9999 999 9 Action Check the wiring of inputs for miswiring disconnections and short circuits and check the input type If no abnormality is found in the wiring and input type turn the power OFF then back ON again If the display remains the same the Controller must be replaced If the display is restored then the probable cause Is electrical noise affecting the control system Check for electrical noise Operation at Error After an error occurs the error is displayed and the alarm outputs function as if the upper limit has been exceeded When the input error output parameter in the advanced function level is set to ON the alarm
69. on bottom of Controller 0 1 to 999 9 FS in units of 0 1 FS Bus power Supplied from USB host Integral time I 0 to 3999 s in units of 1 s Power supply controller Derivative time D 0 to 3999 s ogee of 1s Power supply voltage 5 VDC Control period 0 5 1 to 99 s in units of 1 s Current consumption 70 mA Manual reset value 0 0 to 100 0 in units of 0 1 Ambient operating temperature 0 to 55 C with no condensation or icing 1999 to 9999 decimal point position depends on input Alarm setting range type Ambient operating humidity 10 to 80 Sampling period 250 ms Storage temperature a 60 C with no condensation or Thermocouple 0 1 C Q max 100 Q max See note 3 ei a source Platinum resistance thermometer 0 4 C Q max 10 Q Storage humidity 10 to 80 max Altitude 2 000 m max Insulation resistance 20 MQ min at 500 VDC Ees 2 000 VAC 50 or 60 Hz for 1 min between terminals with pegon SS 1999 g different charge Note A driver must be installed in the personal computer Refer to E Malfunction 10 t0 55 Hz 20 m s for 10 min each in X Y and Z installation information in the operation manual for the a on directions Conversion Cable tance Destruction 10 t0 55 Hz 0 75 mm single amplitude for 2 hrs each in E oe X Y and directions Communications Specifications Shock Malfunction 100 m s min 3 times each in X Y and Z directions z resis Transmission
70. ontrol output 1 is less than 190 ms heater burnout and the heater current will not be measured 2 Ifthe OFF time of control output 1 is less than 190 ms heater short alarm and the heater current will not be measured Heater short alarm setting range Electrical Life Expectancy Curve for Relays Reference Values e Life x 10 operati E5CZ 250 VAC 30 VDC resistive load coso 1 0 1 2 3 4 5 6 Switching current A E5CZ E5CZ U E54 CT1 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Q ua 100 V E50 Hz E 10 o gt 1 kQ Distortion actor 10 Lu 1 3 ab o a 1 100 mV reo gt 3 10 00 Q 1 RL 10Q 100 uV 10 1 10 100mA 1 10 100 1 000A Thru current lo A r m s E54 CT3 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Temperature Controller is 50 A Number of windings 400 2 Winding resistance 840 8 Q
71. ontrol output pa amilon g Previous model New model urnout ns E5AZ R3 Relay output No fno E5AZ A3 E53 AZR E9AZ R3T Voltage output E5AZ Q3 for driving SSR fe E5AZ A3 E53 AZQ FSAZ Q3T Current output No Shee 53 Azc__ ESAZ C3T Thermocouple Relay output Yes E5AZ R3 E53 AZM_ E5AZ R3MT or Resistance 3 Voltage opi thermometer z o for driving SSR Yes E5AZ Q3 E53 AZM ESAZ Q3MT 240 VAC Current output Yes E5AZ C3 E53 AZM E5AZ C3MT E5AZ R3 E53 AZM Relay output Yes CT1 Yes E53 AZH E5AZ R3HMT Voltage output E5AZ Q3 E53 AZM AON for driving SSR eS CT1 Yes E53 AZH ESALQJEMT 96 x 96 x 78 Relay output Yes CT1 Yes None E5AZ R3HML pour Analog current 3 Voltage output Yes CT1 Yes Nene E5AZ Q3HML voltage for driving SSR Current output No Yes None E5AZ C3ML Relay output No Yes None E5AZ R3MTD Voltage output Thermocouple for driving SSR Yes None ESAZ Q3MTD ra Dstt 3 Current output No Yes None E5AZ C3MTD Relay output Yes CT1 Yes None E5AZ R3HMTD 24 VAC VDC Voltage output Yes CT1 Yes None E5AZ Q3HMTD Relay output Yes CT1 Yes None E5AZ R3HMLD Analog current Voltage output voltage 3 for driving SSR Yes CT1 Yes None E5AZ Q3HMLD OMRON ES5AZ E5EZ Controllers with Terminal Blocks Functions l Power supply Alarm H R Size Input type Control output eater Mounting Previous model New model voltage
72. oop break alarm multi SP MV limiter input digital filter self tuning temperature input shift run stop protection functions etc 10 to 55 C with no icing or condensation 25 to 85 25 to 65 C with no icing or condensation OMRON E5C2Z E5CZ U Input Ranges Thermocouples Platinum Resistance Thermometers Universal Inputs Therm Infrared temperature sensor K J T E 115to 165 C Input Type Name 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 100 0 200 0 Temperature range C Setting number The applicable standards for the input types Platinum resistance thermometer ocouple ee eee ee a eee 10to 70 C 60 to 120 C Analog input 140t 14010 0 to 50 mV Usable in the following ranges by scaling 1999 to 9999 or 199 9 to 999 9 2 U Cu CuNi DIN 43710 1985 are as follows K J T E N R S B IEC584 1 Pt100 IEC 751 JPt100 JIS C 1604 1989 JIS C 1606 1989 L Fe CuNi DIN 43710 1985 Models with Analog Inputs Input Type Input specification 4 to 20mA O to 20 mA 1 to 5V 0 to5V Setting range Setting number Voltage Oto 10V Usable in the following ranges by scaling 1999 to 9999 199 9 to 999 9 19 99 to 99 99 or 1 999 to 9 999 o V R B H OMRON 00 14 115
73. ote 1 When returning from the initial setting level to the operation level the default in the operation level will be displayed 2 When returning from the protect level to the operation level the default in the operation level will be displayed Je niror in Progress Control Stopped e SS Operation eanes oo Adusimentlovel feansese o Manual control leve Canbest J inal settingievel o e anes Advanced function setting level See note Canbeset Communications settinglevel Canbest Note Set the parameters in the initial setting communications protect under protect level to 0 to activate advanced function setting level Of these levels the initial setting level communications setting level and advanced function setting level can be used only when control has stopped Note that controller outputs are stopped when any of these three levels are selected With the exception of operation level the present level will be displayed No 3 display will show the following when settings are being changed Ce tect evel ads dCAdustment evel ea S Cia setting Tove Cirsa Communications soting evel Rds Advanced function setting evel OMRON E5EZ PRR Descriptions of Each Level Protect Level Operation Level Adjustment Level Manual Control Level Initial Setting Level Advanced Function Setting Level Communications Setting Level OMRON To select
74. output E5CZ R2TDU 24 VAC VDC Resistance thermometer Voltage output for driving SSR E5CZ Q2TDU Accessories Order Separately USB Serial Conversion Cable Adapter Model Connectable models Model E58 CIFQ1 Terminal block models Y92F 45 Terminal Cover Note a when the panel has been previously prepared I I Terminal block z Connectable models erminal block models Sockets for Plug in Models Model E53 COV17 i Type Model Waterproof Packing Front connecting Socket P2CF 11 Model Front connecting Socket with Finger Protection P2CF 11 E Y92S 29 Back connecting Socket P3GA 11 Note The Waterproof Packing is included with the Controller only for Terminal Cover for Back connecting socket with Current Transformers CTs Hole diameter Model 5 8 dia E54 CT1 12 0 dia E54 CT3 OMRON Specifications Ratings Power supply voltage Operating voltage range Power con E5CZ E5C2Z E5CZ U 100 to 240 VAC 50 60 Hz 24 VAC 50 60 Hz or 24 VDC 85 to 110 of rated supply voltage 7 5 VA 5 5 VA 24 VAC 3 5 W 24 VDC sumption E5CZ U 6 VA 4 5 VA 24 VAC 2 5 W 24 VDC Sensor input Models with temperature inputs Thermocouple K J T E L U N R S or B Platinum resistance thermometer Pt100 or JPt100 Infrared temperature sensor 10 to 70 C 60 to 120 C 115 to 165 C or 140 to 260 C Voltage input 0 to 50 mV Models with analog inputs Current input 4 to 20 mA or 0 to 20 mA Voltage inpu
75. perations 21 When extending the thermocouple lead wires always use compensating conductors suitable for the type of thermocouple Do not extend the lead wires on a platinum resistance thermometer Use only low resistance wire 5 Q max per line for lead wires and make sure that the resistance is the same for all three wires 22 When drawing out the Temperature Controller from the case do not apply force that would deform or alter the Temperature Controller 23 When drawing out the Temperature Controller from the case to replace the Temperature Controller check the status of the terminals If corroded terminals are used contact faults with the terminals may cause the temperature inside the Temperature Controller to increase possibly resulting in fire If the terminals are corroded replace the rear case as well 24 When drawing out the Temperature Controller from the case turn the power supply OFF first and absolutely do not touch the terminals or electronic components or apply shock to them When inserting the Temperature Controller do not allow the electronic components to come into contact with the case 25 Static electricity may damage internal components Always touch grounded metal to discharge any static electricity before handling the Temperature Controller When drawing out the Temperature Controller from the case do not touch the electronic components or patterns on the board with your hand Hold the Temperature Controller by
76. proof packing onto the Controller When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the ambient operating temperature given in the specifications E5CZ U Plug in Models Individual Mounting 60 min _ 45 O Mounting Adapter Accessory Note There is no waterproof function for the E5CZ U Panel Cutout Group Mounting 48 x number of units 2 5 wi 45 eg 45 TS Recommended panel thickness is 1 to 5mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the ambient operating temperature given in the specifications OMRON E5C2Z E5CZ U Accessories USB Serial Conversion Cable Order Separately E58 CIFQ1 2 100 250 g Do o noo USB connector type A plug LED indicator SD IG ial LED indicator RD SEU enconeelo Terminal Cover Order Separately Waterproof Packing E53 COV17 48 Y92S 29 for DIN 48 x 48 T CS Order the Waterproof Packing separately if it becomes lost or damaged The Waterproof Packing can be used to achieve an IP66 indoor use degree of protection NS Deterioration shrinking or hardening of the waterproof packing may occur depending on
77. put Temperature unit C F E is Celsius and F is Fahrenheit SP upper limit Limit the set point SP lower limit Direct reverse operation Direct operation an d Reverse operation ar Alarm 1 type Select alarm mode Alarm 2 type Closed floating Floating Fiat Closed 145 Motor calibration Motor calibration an Cancel aFF Travel time Switch to advanced function setting level To switch to the advanced function setting level the initial setting communications protect parameters must be set to 0 Operation level Added when Additional PV display is ON Process value Process value set value valve open percentage Multi SP set point setting Set point during SP ramp RUN STOP Run ehia Stop 5taF Alarm value 1 parameters Alarm value upper limit 1 Alarm value lower limit 1 Alarm value 2 Set either of these parameters Alarm value upper limit 2 Alarm value lower limit 2 Set either of these Adjustment level AT execute cancel AT execute 57 AT cancel aFF Communications writing Enabled an Disabled FF SP used by Multi SP Temperature 1 point shift input shift values Upper limit temperature shift When using a Infrared temperature sensor 2 point shift Lower limit temperature shift When using a Infrared temperature sensor
78. put is set in Position proportional dead bana and the hysteresis is set in Open Close hysteresis The relation to valve opening is shown below Open close hysteresis Dead band A A MvV Valve opening 100 100 When the present value is inside the PV dead band this function is used to per form control for PV SP and stop unnecessary output when the PV is close to the SP Use this setting to select whether to stop control or switch to floating control and continue when a potentiometer error occurs during closed control OMRON E5EZ PRR Meeting all of your temperature control needs in a wide range of applications ES1B Infrared Temperature Sensor Perform measurements with a contract free sensor at minimal costs e Outputs electromotive forces identical to those of thermocouples so that it can be connected directly to temperature controllers that generally use thermocouple input e 4 types of specifications Can be used in all types of temperature measurements from food products packaging and finished product all the way to electrical engineering e 300 ms high speed response 63 response time 1 and PV s reenactment capabilities ensuring high accuracy temperature measurements e Compared to thermocouples this product has the advantage of being resistant to aging and can maintain steady real time control Note For more detailed information please refer to other ES1B related materials
79. r displayed repairs will be necessary ne error See note 2 If the Temperature Controller is normal after cycling the power supply the error may have been caused by noise Check for noise being generated nearby E iii E111 Memory error Cycle the power supply If the same error is still displayed repairs will be necessary OFF ea HB error If the Temperature Controller is normal after cycling the power supply the error may have LERR H Err See note 2 been caused by noise Check for noise being generated nearby OFF Note 1 Ifthe input value exceeds the display limit 1999 to 9999 though it is within the control range lEceE will be displayed under 1999 and 3333 above 9999 Under these conditions control output and alarm output will operate normally For details on the control range refer to the E5CZ E5CZ U E5AZ E5EZ Digital Temperature Controllers User s Manual Cat No H207 2 These errors are displayed only when the PV SP is displayed Errors are not displayed in other display modes OMRON E5 Z E5 IZ Parameters Some parameters are not displayed depending on the model of the Controller and parameter settings For details Press the O Key for at refer to the ES5CZ E5CZ U E5AZ E5EZ Digital Eo ieee Temperature Controllers User s Manual Cat No H207 Power ON automatic and manual Starting in manual mode Manual control level S
80. r Press the at least 1 s display will flash O Key Press the Oll Key for at least 3 s while A for at least 1 s Press the O ce Keys for at least 3 s See note Manual Control Communi Level Initial Setting Level cations Setting Protect level Press the Ol Key for less than 1 s Input password Note The time taken to move Set value 169 to the protect level can be adjusted by changing the Move to protect level time Press the O Key for at least 1 s Advanced Function Setting Level Control in progress Control stopped Not displayed for some models t ODL Level change Note 1 Moves to operation level by software reset 2 From the manual control level key operations can be used to move to the operation level only Error Displays Troubleshooting When an error occurs the No 1 display shows the error code Take necessary measure according to the error code referring the table below Output status at error No 1 display Meaning Action Control outputs Alarm outputs Input error Check the wiring of inputs for miswiring disconnections and short circuits and check the Operates as above the upper See note 2 input type limit Check for an input error and then cycle the power supply If the same error is still A D converte
81. r into the case do not force it into the case Doing so will damage internal parts 14 The EEPROM has a limited write life When overwriting data frequently e g via communications use RAM Mode 15 Use the product within the rated load and power supply 16 Use a switch relay or other contact so that the power supply voltage reaches the rated voltage within 2 seconds If the applied voltage is increased gradually the power supply may not be reset or malfunctions may occur OMRON E5EZ PRR 17 When using PID operation self tuning turn ON the power supply to the load e g heater at the same time or before turning the power supply to the Temperature Controller ON If power is turned ON for the Temperature Controller before turning ON power supply to the load self tuning will not be performed properly and optimum control will not be achieved 18 Design the system e g control panel to allow for the 2 seconds of delay required for the Temperature Controller s output to stabilize after the power is turned ON 19 A switch or circuit breaker should be provided close to this unit The switch or circuit breaker should be within easy reach of the operator and must be marked as a disconnecting means for this unit 20 Approximately 30 minutes is required for the correct temperature to be displayed after turning the power supply to the Temperature Controller ON Turn the power supply ON at least 30 minutes prior to starting control o
82. r limit Orr i OFF al _ 4 E ON L H See note 1 Upper and lower limit range OFF as See noise a 5 ee ON m Hie See note 1 Upper and lower limit with standby sequence OFF rened SP See note 5 zoa gt X X ee 6 Upper limit with standby sequence e l Bre i SP SP ee ON 2XIe ON zat Se 7 Lower limit with standby sequence OFF Lan k orr P limi ON x ON ix 8 Absolute value upper limit Ope Orr E Q OO 9 Absolute value lower limit ON tX ON x a ee limit wi ON xX ON oO 10 Absolute value upper limit with standby sequence OFF i OFF E n PE ON LX Lx 11 Absolute value lower limit with standby sequence OFF E _ OPE 0 Note 1 Upper and lower limit values can be set independently for each alarm type and are expressed as L and H The set values are 1 4 and 5 2 Set value 1 Upper and lower limit alarm Case 1 Case 2 Case 3 Always ON Ea lt 0 lt 0 L H SP SPL H L SP H H lt 0 L gt 0 H gt 0 L lt 0 mais 11 lt 0 1 gt 0 IH lt L IH gt L H LSP H JL H gt 0 L lt 0 SPH L IH lt L 3 Set value 4 Upper and lower limit range Case 1 Case 2 Case 3 Always OFF H lt 0 L lt 0 L H SP SPL H Pe H lt 0 L gt 0 H gt 0 L lt 0 fy H lt 0 L lt 0 IH lt L IH gt L H LSP IH gt L H lt 0 L lt 0 SPH L IH lt IL 4 Set value 5 Upper and lower limit with standby sequence e The upper and lower limit alarms described above e In cases 1 and 2 if there is significant overlap between
83. re Controllers Communications Manual Cat No H208 E5CZ E5CZ U Model Number Structure Model Number Legend Controllers Option Units E5CZ J2M_I_ E53 CZi_ IL 123 45 123 1 Control Output 1 1 Applicable Controller R Relay output CZ E5CZ Q Voltage output for driving SSR 2 Function 1 C Current output Blank None 2 Number of Alarms H Heater burnout Heater short detection CT 1 2 Two alarms 3 Function 2 3 Option B Two event inputs Blank None 03 RS 485 communications M Option Unit can be mounted 4 Input Type T Thermocouple infrared sensor platinum resistance thermometer L Analog current voltage input 5 Power Supply Voltage Blank 100 to 240 VAC D 24 VAC VDC Note Not all combinations of function 1 and function 2 specifications are possible for Option Units E53 CZ _IL Ordering Information Controllers with Terminal Blocks r Power supply Mounting Previous Size voltage Input type Alarm output option units Control output model New model Relay output E5CZ R2 E5CZ R2T Voltage output y E5CZ Q2 E5CZ Q2T Thermocouple or for driving SSR Resistance 2 Relay output E5CZ R2M E5CZ R2MT thermometer Voltage output ae E5CZ Q2M E5CZ Q2MT 100 to 240 VAC for driving SSR Current output E5CZ C2M E5CZ C2MT Relay output E5CZ R2ML 1 16 DIN Analog Voltage output 48 x 48 x78 current voltage for driving SSR one ESGAQZML WxH x D Current output None E5CZ C2ML Relay outpu
84. rew at the bottom of the front panel with a screwdriver while pressing down on the hook at the top of the front panel 120 min Waterproofing is not possible when i group mounting Controllers e Recommended panel thickness is 1 to 8mm e Group mounting is not possible in the vertical direction Maintain the 92 0 8 specified mounting space between 9 Controllers e To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the ambient operating temperature given in the specifications OMRON ES5AZ E5EZ E5EZ Terminal Models NE d EN AN Up Waterproof Packing Mounting Bracket Accessory Accessory 11 2 N ISSA Y i 112 Waterproof Packing Mounting Bracket Terminal Cover E53 COV11 Accessory Accessory Order separately Crimp terminal size M3 5 Panel Cutout Individual Mounting Group Mounting 48 x number of units 2 5 5 45 06 I 92 9 3 Note To remove the Controller from the case loosen the screw at the bottom of the front panel with a screwdriver while Waterproofing is not possible when pressing down on the hook at the top of the front panel i group mounting Controllers Recommended panel thickness is 1 to 8mm Group mounting is not possible in the vertical direction Main
85. shorter the service life and the lower the temperature the longer the service life Therefore the service life can be extended by lowering the temperature of the Temperature Controller 3 When two or more Temperature Controllers are mounted horizontally close to each other or vertically next to one another the internal temperature will increase due to heat radiated by the Temperature Controllers and the service life will decrease In such a case use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers When providing forced cooling however be careful not to cool down the terminals sections alone to avoid measurement errors Measurement Accuracy 1 When extending or connecting the thermocouple lead wire be sure to use Compensating wires that match the thermocouple types 2 When extending or connecting the lead wire of the platinum resistance thermometer be sure to use wires that have low resistance and keep the resistance of the three lead wires the same 3 Mount the product so that it is horizontally level 4 Ifthe measurement accuracy is low check to see if input shift has been set correctly Waterproofing The degree of protection is as shown below Sections without any specification on their degree of protection or those with IPL10 are not waterproof ae Front panel IP66 indoor use Rear case IP20 Terminal section IP00 E5EZ E5CZ U Front panel Equivalent to IP50 re
86. so may occasionally result in fire When inserting the body of the Temperature Controller into the case confirm that the hooks on the top and bottom are securely engaged with the case If the body of the Temperature Controller is not inserted properly faulty contact in the terminal section or reduced water resistance may occasionally result in fire or malfunction Note 1 An SELV circuit is one separated from the power supply with double insulation or reinforced insulation that does not exceed 30 V r m s and 42 4 V peak or 60 VDC 2 Aclass 2 power supply is one tested and certified by UL as have the current and voltage of the secondary output restricted to specific levels 3 The tightening torque for E5CZ U is 0 5 N m OMRON E5 IZ Precautions for Safe Use Be sure to observe the following precautions to prevent malfunction or adverse affects on the performance or functionality of the product Not doing so may occasionally result in faulty operation 1 This product is specifically designed for indoor use only Do not use this product outdoors or in any of the following places e Places directly subject to heat radiated from heating equipment e Places subject to splashing liquid or oil atmosphere e Places subject to direct sunlight e Places subject to dust or corrosive gas in particular sulfide gas and ammonia gas e Places subject to intense temperature change e Places subject to icing and condensation
87. subject to icing and condensation e Places subject to vibration and large shocks 2 Use and store the product within the rated temperature and humidity ranges Group mounting two or more Temperature Controllers or mounting Temperature Controllers above each other may cause heat to build up inside the Temperature Controllers which will shorten their service life In such a case use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers 3 To allow heat to escape do not block the area around the product Do not block the ventilation holes on the product 4 Use the specified size M3 5 width of 7 2 mm or less crimped terminals for wiring To connect bare wires to the terminal block use copper braided or solid wires with a gage of AWG24 to AWG 14 equal to a cross sectional area of 0 205 to 2 081 mm The stripping length is 5 to 6 mm Up to two wires of the same size and type or two crimp terminals can be inserted into a single terminal 5 Be sure to wire properly with correct polarity of terminals Do not wire any of the I O terminals incorrectly 6 Do not wire the terminals that are not used 7 The voltage output control output is not electrically isolated from the internal circuits When using a grounded temperature sensor do not connect any of the control output terminals to ground Otherwise unwanted current paths will cause measurement errors 8 To avoid inductive noise
88. t c Signal inputs are SELYV limited energy See note 1 d Caution To reduce the risk of fire or electric shock do not interconnect the outputs of different Class 2 circuits See note 2 If the output relays are used past their life expectancy contact fusing or burning may occasionally occur Always consider the application conditions and use the output relays within their rated load and electrical life expectancy The life expectancy of output relays varies considerably with the output load and switching conditions Tighten the terminal screws to between 0 74 and 0 90 N m Loose screws may occasionally result in fire See note 3 Set the parameters of the product so that they are suitable for the system being controlled If they are not suitable unexpected operation may occasionally result in property damage or accidents A malfunction in the product may occasionally make control operations impossible or prevent alarm outputs resulting in property damage To maintain safety in the event of malfunction of the product take appropriate safety measures such as installing a monitoring device on a separate line Seoqor gt COOOOPF E5 Z Do not allow pieces of metal or wire cuttings to get inside connectors Failure to do so may occasionally result in minor electric shock fire or damage to equipment Do not allow dust and dirt to collect between the pins in the connector on the Conversion Cable Failure to do
89. t the alarm value to 30 C Start operation E5EZ PRR Setting Level Configuration and Key Operations Parameters are divided into groups each called a level Each of the set values Setup items in these levels are called a parameter The parameters on the E5EZ PRR are divided into the following seven levels Started in automatic mode Started in manual mode Press the 4 key for at least 1 s Operation Level O Ce key PV display flashes Press O key less than 1 s Press the O ce keys Press the O key for at least 1 s for at least 1 s display will flash Press the O key for atleast 3 s Control stops Press the Press the aml key for OJ key for at least 1 s at least 1 s Manual Mode O S key for atleast 3 s See note 1 See note 2 Manual me Communications Control Level Initial Setting Level E Senno Level Protect Level Press O key less than 1 s Press O key for at least 1 s Input password Set value 169 The time taken to move to the protect level can be adjusted by changing the Move to protect level Advanced Function time setting C Control in progress C Control stopped Not displayed for some models lt Level change Setting Level N
90. t 1 to 5 V 0 to 5 V or O to 10 V Input impedance Current input 150 Q Voltage input 1 MQ Use a 1 1 connection when connecting the ES2 HB SPST NO 250 VAC 3 A resistive load electrical life 100 000 operations minimum applicable EA ESCZ load 5 V 10 mA utpu TOSE SPDT 250 VAC 3 A resistive load electrical life 100 000 operations minimum applicable load E5CZ U Control 5 V 10 mA output Voltage output 5c7 for driving E5CZ U Output voltage 12 VDC 15 PNP max load current 21 mA with short circuit protection circuit SSR Current output E5CZ 4 to 20 mA DC 0 to 20 mA DC load 600 Q max resolution approx 2 700 Alarm output SPST NO 250 VAC 1 A resistive load electrical life 100 000 operations minimum applicable load 5 V 10 mA Contact input Non contact Event input input Control method ON 1 kQ max OFF 100 KQ min ON Residual voltage 1 5 V max OFF Leakage current 0 1 mA max Outflow current Approx 7 mA per point ON OFF control or 2 PID control with auto tuning Setting method Digital setting using front panel keys Indication method 11 segment digital display and individual indicators 7 segments displays also possible Character height PV 11 mm SV 6 5 mm Other functions Ambient operating temperature Ambient operating humidity Storage temperature Manual output heating cooling control transfer output on some models l
91. t E5CZ R2MD_ E5CZ R2MTD Thermocouple or Voltage output g Resistance 2 for driving SSR E5CZ Q2MD E5CZ Q2MTD thermometer Current output E5CZ C2MD E5CZ C2MTD 24 VAC VDC Relay output E5CZ R2MLD Analog Voltage output i current voltage i for driving SSR ESCA QEMLD Current output E5CZ C2MLD Option Units One of the following Option Units can be mounted to provide the E5CZ with additional functions Functions Previous model New model Communications RS 485 o o CYNON E53 CZ03 Communications RS 485 E53 CNHO3N E53 CZH03 Event inputs E53 CNBN E53 CZB Heater burnout Event inputs E53 CNHBN E53 CZHB Note Option Units cannot be used for plug in models These Option Units are applicable only to models released after October 2008 OMRON E5CZ E5CZ U Model Number Structure Model Number Legend Plug in type Controllers E5CZ Ll2TLIU 12345 1 Output Type 4 Power Supply Voltage R Relay Blank 100 to 240 VAC Q Voltage output for driving SSR D 24 VAC VDC 2 Number of Alarms 5 Plug In type 2 Two alarms J Plug in type 3 Input Type T Thermocouple infrared sensor platinum resistance thermometer Ordering Information Plug in type Controllers Plug in Type Controllers A Power supply Previous Size voltage Input type Alarm output Control output New model Thermocouple or Relay output E5CZ R2TU 100 to 240 VAC Resistance _ TEON thermometer Voltage output for driving SSR E5CZ Q2TU Thermocouple or Relay
92. t in electric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise minor injury from explosion may occasionally occur Never disassemble modify or repair the product or touch any of the internal parts Minor electric shock fire or malfunction may occasionally occur CAUTION Risk of Fire and Electric Shock a This product is UL listed as Open Type Process Control Equipment It must be mounted in an enclosure that does not allow fire to escape externally b More than one disconnect switch may be required to de energize the equipment before servicing the product c Signal inputs are SELV limited energy See note 1 d Caution To reduce the risk of fire or electric shock do not interconnect the outputs of different Class 2 Circuits See note 2 If the output relays are used past their life expectancy contact fusing or burning may occasionally occur Always consider the application conditions and use the output relays within their rated load and electrical life expectancy The life expectancy of output relays varies considerably with the output load and switching conditions Loose screws may occasionally result in fire Tighten terminal screws to the specified torque of 0 74 to 0 90 N m Unexpected operation may result in equipment damage or accidents if the settings are not appropriate for the controlled system Set the Temperature Controller as follows A malfunc
93. ta length See note 2 7 or 8 bits Stop bits See note 2 1 or 2 bits Error detection Vertical parity none even odd Block check character BCC Flow control Interface Retry function Not available RS 485 RS 232C Not available OMRON E5EZ PRR Specifications Characteristics Indication accuracy Thermocouple 0 5 of indicated value or 1 C whichever is greater 1 digit max See note 1 Platinum resistance thermometer 0 5 of indicated value or 1 C whichever is greater 1 digit max Analog Input 0 5 FS 1 digit max Potentiometer Input 5 FS 1 digit max Influence of temperature See note 2 Influence of voltage See note 2 Proportional band P 0 4 to 999 9 EU in units of 0 1 EU 0 oo Proportional band P R S and B thermocouple inputs 1 of PV or 10 C whichever is greater 1 digit max Other thermocouple inputs 41 of PV or 4 C whichever is greater 1 digit max 10 C for 100 C or less for K sensors Platinum resistance thermometer inputs 41 of PV or 2 C whichever is greater 1 digit max Analog inputs 1 of FS 1 digit max Integral time I Derivative time D With floating control 1 to 3999 s 0 to 3999 s in units of 1 s 0 to 3999 s in units of 1 s Control period 1 to 99 s in units of 1 s Manual reset value Alarm setting range 1999 to 9999 decimal point position depends on input type
94. tain the g2 0 8 specified mounting space between Controllers To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller e When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the ambient operating temperature given in the specifications OMRON ES5AZ E5EZ Accessories USB Serial Conversion Cable Order Separately E58 CIFQ1 2 100 a 250 gt LED indicator SD p 1 765 gt OO Ht ME USB connector type A plug ial LED indicator RD SE oo Terminal Covers Waterproof Packing Y92S P4 for DIN 96 x 96 Y92S P5 for DIN 48 x 96 Order the Waterproof Packing separately if it becomes lost or damaged The Waterproof Packing can be used to achieve an IP66 indoor use degree of protection Deterioration shrinking or hardening of the waterproof packing may occur depending on the operating environment Therefore periodic replacement is recommended to ensure the level of waterproofing specified in IP66 indoor use The time for periodic replacement depends on the operating environ ment Be sure to confirm this point at your site Consider one year a rough Unit Labels Order Separately standard OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement The Waterproof Packing does not
95. tarting in automatic mode r Press the O Key for at least 1 s Press the O Key less than 1 s Adjustment Level perationtevel Level Press the O Key less than 1 s X g ye oO BY _ 10 Process value Alarm value 1 z F Proportional band Ege Added when Additional ge 7 S Va PV display is ON Te sf ge E zJ Al D B 75 Process value BAL IH R init 4 D sj B _ Integral time Ega Set point oo UPP Age SFF Fos 275 PID settin ee 5 pa SF ea e ER HE i M Auto manual switch ore Ee n Alarm value 4 ce ri i i PID control only FL IL lower limit 1 2
96. ternal noise e Use wires with a gage of AWG24 cross sectional area 0 205 mm to AWG14 cross sectional area 2 081 mm twisted pair cable stripping length 5 to 6 mm e Use crimp terminals when wiring the terminals e Tighten the terminal screws to a torque of 0 74 to 0 90 N m e Use the following types of crimp terminals for M3 5 screws Tc 7 7 2 mm max 7 2 mm max e Do not remove the terminal block Doing so may result in malfunction or failure OMRON Digital Position Proportional Controllers E5EZ PRR A position proportional control model for the E5EZ PRR series e Depth of only 78 mm e Various temperature inputs thermocouple platinum resistance thermometer infrared temperature sensor voltage inputs and analog inputs current voltage e Makes use of high visibility LCD with three lines of 4 digit display for simplicity and clarity e 3 lines of display to observe PV SV MV valve open percentage clearly displaying the state of control operations e Event input enables multi SP selection and run stop function e Alarm delay function cage l 48x96 X78 WXHXxXD e Communications function Able to choose closed floating control In floating control CE W Q position proportional control can be performed without a potentiometer e Equipped with a manual output function equipped with an automatic manual key e CE marking and UL CSA certification Note Refer to Precautions on page 59
97. the operating environment Therefore periodic replacement is recommended to ensure the level of waterproofing specified in IP66 indoor use The A time for periodic replacement depends on the operating envi 22 ronment Be sure to confirm this point at your site Consider one year a rough standard OMRON shall not be liable for 48 8 the level of water resistance if the customer does not perform T A periodic replacement 9 1 The Waterproof Packing does not need to be attached if a Note The E53 COV10 cannot be used waterproof structure is not required Note There is no waterproof function for the E5CZ U Unit Labels Order Separately Y92S L1 Type Current Transformers Order Separately E54 CT1 lt 21 UNIT LABEL 30 __ E54 CT3 Accessory Connection Example e Armature Armature Plug pees of AO or maa E54 CT3 D e Plug an Approx 6 dia OMRON E5CZ E5CZ U Adapter Order Separately Note 1 Use this Adapter when the panel has already been prepared for the E5BL 2 Only black is available Y92F 45 Fixture Accessory 76 69 6 to 77 6 2x2 YZZLLLLLLLLILLD D Er m VLLLLLLLLLLLL DA SVLLLLLLLL LLL NS 67x67 87 Mounted to E5CZ OUTI UT3j JHA 77 3 to back of E5CZ gt E5CZ U
98. the upper and lower limit values after hysteresis the alarm will always be OFF Examples of case 1 and 2 In case 3 under general conditions the alarm is turned OFF 5 Set value 5 Upper and lower limit with standby sequence If there are any overlaps in the upper and lower limits for hysteresis the alarm will always be OFF There are alarm types 1 to 2 initial setting level and settings should be made independently for each alarm The default is 2 upper limit OMRON Parameters E5EZ PRR Parameters related to setting items for each level are marked in boxes in the following flowchart and brief descriptions are given as required After finishing each setting press the mode key to return to the beginning of each level Power ON Started in manual mode Started in automatic mode A M Press I key for at least 1 s Operation Level Press O key less than 1 s Press the O key for at least 1 s Press the O for at least 1 s A M Press I key for at least 1 s Press the O at least 3 s Control stops Manual Mode See note 1 Manual Control Level 1 Press O key less than 1 s Initial Setting Level Press O key for at least 1 s Input password Set value 169 Advanced Function Setting Level Note 1 When returning from the initial setting level to the opera
99. ticular motors transformers solenoids magnetic coils or other equipment that have an inductance component When a noise filter is used at the power supply first check the voltage or current and attach the noise filter as close as possible to the product Allow as much space as possible between the product and devices that generate powerful high frequencies high frequency welders high frequency sewing machines etc or surge 8 Use this product within the rated load and power supply 9 Make sure that the rated voltage is attained within 2 seconds of turning ON the power by using a switch or relay contact If the voltage is applied gradually the power may not be reset or output malfunctions may occur 10 Make sure that the Temperature Controller has 30 minutes or more to warm up after turning ON the power before starting actual control operations to ensure the correct temperature display 11 When executing self tuning turn ON power to the load e g heater at the same time as or before supplying power to the product If power is turned ON to the product before turning ON power to the load self tuning will not be performed properly and optimum control will not be achieved 12 A switch or circuit breaker must be provided close to the product The switch or circuit breaker must be within easy reach of the operator and must be marked as a disconnecting means for this unit 13 Always turn OFF the power supply before pulling out th
100. tion in the Temperature Controller may occasionally make control operations impossible or prevent alarm outputs resulting in property damage To maintain safety in the event of malfunction of the Temperature Controller take appropriate safety measures such as installing a monitoring device on a separate line Be sure that the platinum resistance thermometer type and the input type set on the Temperature Controller are the same 9 00k E OOOPE Note 1 A SELV circuit is one separated from the power supply with double insulation or reinforced insulation that does not exceed 30 V r m s and 42 4 V peak or 60 VDC 2 Aclass 2 power supply is one tested and certified by UL as having the current and voltage of the secondary output restricted to specific levels E5EZ PRR Precautions for Safe Use Be sure to observe the following precautions to prevent operation failure malfunction or adverse affects on the performance and functions of the product Not doing so may occasionally result in unexpected events 1 The product is designed for indoor use only Do not use the product outdoors or in any of the following locations e Places directly subject to heat radiated from heating equipment e Places subject to splashing liquid or oil atmosphere e Places subject to direct sunlight e Places subject to dust or corrosive gas in particular sulfide gas and ammonia gas e Places subject to intense temperature change e Places
101. tion level the default in the operation level will be displayed 2 When returning from the protect level to the operation level the de fault in the operation level will be displayed Display lt No 1 Display lt No 2 Display lt No 3 Display Adjustment Level key display will flash key for Communications Setting Level key PV display flashes Press the OJ keys for at least 1 s mm RIRN 2000AN OJj cE key for at least 3 s See note 2 Protect Level The time taken to move to the protect level can be adjusted by changing the Move to protect level time setting Not displayed for some models lt Level change Power ON Press the O key for at least 1 s Advanced function setting level Press the O key for at least 1 s Press the O key for at least 3 s Note To select the advanced function setting level you must input the password 169 in the initial setting level Initial setting level ____ Operation level Press the O key for less than 1s Adjustment level Press the O key for less than 1s OMRON E5EZ PRR Parameter Flow e In each level if you press the mode key on the final parameter you will return to the parameter at the top of the level Advanced function setting level Parameter initialization Num
102. umber of units 2 5 F 92 8 20 e Recommended panel thickness is 1 to 8 mm e Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers e When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications above 1 Terminal Covers Order Separately E53 COV18 Available only for E5EZ PRR 3 p D p LOLOL OLOLO LOLOL OLELE COLA OLOJOLOAOA CAEL OMRON E5EZ PRR Wiring Terminals e Standard insulation is applied to the temperature gauge s I O sections If reinforced insulation is required connect the input and output terminals to a device without any exposed current carrying parts or to a device with standard insulation suitable for the maximum operation voltage of the power supply I O section e For E5EZ PRRLJ03 model products in order to satisfy the conduction and emission specifications of EN61326CLASSA a magnetic ring TDK ZAT1730 0730 should be added to the communications line between the K3SC unit and the controller E5EZ PRR Communications Communications 100 to 240 VAC 50 60 Hz Control Output 1 OPEN Output G Control Output 2 CLOSE Output gt 1 T o OPEN 6 Q 2o Potentiometer WIPE CLOSE 8 A Ta T DO NOT 9 m USE B ee fF amp 10 DONOT v gt
103. ut input ON Residual voltage 1 5 V max OFF Leakage current 0 1 mA max Control method Setting method Indication method Outflow current Approx 7 mA per point ON OFF control or 2 PID control with auto tuning Digital setting using front panel keys 11 segment digital display and individual indicators 7 segments displays also possible Character height E5AZ PV 15 mm SV 9 5 mm E5EZ PV 14 mm SV 9 5 mm Other functions Manual output heating cooling control transfer output on some models loop break alarm multi SP MV limiter input digital filter self tuning temperature input shift run stop protection functions etc Ambient operating temperature 10 to 55 C with no icing or condensation Ambient operating humidity Storage temperature 25 to 85 25 to 65 C with no icing or condensation OMRON ES5AZ E5EZ Input Ranges Thermocouples Platinum Resistance Thermometers Universal Inputs Input Platinum resistance Thermocouple Infrared temperature Analog Type thermometer sensor input 10 60 115 140 Name Pioo JPt100 K J T E L U N RISB 10to 60to 115to 140t0 0 to 50 mV 1700 the rae following 1600 ranges by 1500 ern O o 9909 or 199 9 to 1200 999 9 1100 1000 900 800 700 600 500 400 300 200 100 0 100 0 200 0 Temperature range C Setting 23 number The applica
104. ved models OMRON logo upper left Front panel EA AA AA DA a PAL ANI SAL IAT E5CZ E5CZ U HA Ona Sie om AA AA AA A foura cnn iaanc AAAA AANA AND BAY E M M M M IA IA IA IAI MA AA MA DA INI INI INI IN E5AZ o Bele al EIEE ol SS lalz S EMM DA IV ESEZ INANA AN LLL mee DYN QUT 1 OUT2 STOP oe JA IN N INI E5 Z Specifications Main Changes Ratings tem paproved mode 7 VA 100 to 240 VAG 50 60 Hz 7 5 VA 100 to 240 VAC 50 60 Hz 4 VA 3 W 24 VAC 50 60 Hz or 24 VDC 5 5 VA 3 5 W 24 VAC 50 60 Hz or 24 VDC 6 VA 100 to 240 VAC 50 60 Hz Power No models with plug in type 4 5 ee W 24 VAC 50 60 ae 24 VDC consump tion 9 VA 100 to 240 VAC 50 60 Hz 8 5 VA 5 VA 4 W 24 VAC 50 60 Hz or 24 VDC 6 VA 4 W 9 VA 100 to 240 VAC 50 60 Hz 8 5 VA ee 5 VA 4 W 24 VAG 50 60 Hz or 24 VDC 6 VA 4 W E5SUZ OOUULLI Models with analog inputs added Sensor input No models with analog inputs Current input 4 to 20 mA or 0 to 20 mA Voltage input 1 to 5 V Oto5V or0to10V E5CZ RULLI E5CZ RUULULI SPST NO 250 VAC 3 A resistive load SPST NO 250 VAC 3 A resistive load Electrical life 100 000 operations Electrical life 100 000 operations E5CZ RULUILIU No models with plug in type SPDT 250 VAC 3 A resistive load Electrical life 100 000 operations E5AZ RULILI E5AZ RUUIUILI SPST NO 250 VAC 5 A resistive load SPST NO 2
105. vel 2 Retry function None Immunity Burst EN61000 4 4 2 kV Power line level 3 ee 1 kV I O signal line level 3 See note 5 Communications 40 bvtes Immunity Surge EN61000 4 5 1kV line to line buffer y Power line output line relay output 2 kV line t d oo 0 to 99 Power ine output ine relay output Send data wait time nice mo ine to groun EEE E neue ne eee Note The baud rate data length stop bits and vertical parity can be pin anes EN610004 11 05 ade 10086 ated individually set using the Communications Setting Level voltage Approved standards ULG1010C1 yg Current Transformer Order Separately EN61326 EN61010 1 IEC61010 1 Ratings Conformed standards VDE0106 Part 100 Finger protection when the terminal COVEN MOUNIER Dielectric strength 1 000 VAC for 1 min Note 1 The indication accuracy of K thermocouples in the 200 to 7 1300 C range T and N thermocouples at a temperature of aea A 50 Hz 98 m s 100 C max and U and L thermocouples at any temperature is 2 C 1 digit maximum The indication Weight E54 CT1 Approx 11 5 g E54 CT3 Approx accuracy of the B thermocouple at a temperature of 400 C 50 g max is not specified The indication accuracy of the R and Accessories Armatures 2 S thermocouples at a temperature of 200 C max is 3 C 1 E54 CT3 only Plugs 2 digit max 2 Conditions Ambient temperature 10 C to 23 C to 55 C Voltage range 15 to 10 of rated voltage 3
106. ype Connect the open side of the position proportional valve to OUT1 and connect the closed side to OUT2 Ceramic kiln combustion Sensor Position proportional valve Burner Select the value control type and perform floating control using Position proportional value with travel time of 45 seconds Set SP ramp to change SP within a width of 10 0 C minute Time from completely open to completely close The related setting data and settings are as follows Direct reverse operation r r Reverse operation initial setting Closed floating Flat Floating initial setting Travel time 45 seconds SP ramp set value 10 The travel time and SP ramp set value are set in the following and the initial settings are used for all other parameters 1 Press the O key for at least 3 seconds to switch from the operation level to the initial setting level 2 Press the ce key repeatedly to select Ast Travel time Press the A key to set the value to Whew tof 3 Press the O key for at least 1 second to return to the operation level When present value set value valve open percentage is displayed press the IA key to set the set value to 250 4 Press the O key for less than 1 second to switch from operation level to adjustment level 5 Press the el key repeatedly to select 5P amp SP ramp set
Download Pdf Manuals
Related Search
Related Contents
最近の不正競争防止法に関する判決紹介 XP56 SERIE TeleWell TW-EA510 v3 ADSL2+ Router WLAN 54 Mbps (802.11b+g) the User Manual João Pedro Figueiredo Bravo de Faria Sistema de visão por Guía de inicio rápido Service Manual - Kymco Spare Parts User manual Innovationsmanagement für bauausführende Unternehmen user manual for rfscat simulator Copyright © All rights reserved.