1. e Click Finish Projects documentation and tools The user manual for the Guardmaster_440C_CR30 is available from the Help gt Device Manuals menu The manual has not been updated for CCW 7 APBC00018733 Workaround To obtain the latest user manual from the Literature Library go to http literature rockwellautomation com e Additionally you can click Help gt View Help and locate the Safety Relay book in the help table of contents e Go to http ab rockwellautomation com Relays and Timers Safety Relays Guardmaster 440C CR30 documentation If you create a project leave the project open switch to a different user open a new instance of Connected Components Workbench and create another project you may receive a catalog error and you will not be able to create a new project APBC00017014 If after you install the English version of CCW you change the language format text to the Turkish language you may receive unexpected results including the following e Broken help links when you reopen a project e Non English characters that display when you debug your program e Inability to use the filter feature in a language editor for certain characters e Failed build because the project name or folder contains invalid characters APBC00015798 APBC00016210 APBC00015858 If while using the English version of CCW you enter non English characters in a string variable the characters may not display properly after you save close a
2. Installation and Upgrades Installing Connected Components Workbench Follow these steps to install Connected Components Workbench 1 Verify your system meets or exceeds the System Requirements 2 Download the current version of Connected Components Workbench Standard or Developer Edition 3 Launch Setup exe 4 Follow the prompts in the Connected Workbench Setup window 5 optional If installing the Developer Edition enter your serial number into the installer when prompted Note CCW determines the correct components to upgrade and or install If there is a reboot requirement reboot the operating system so the install can complete successfully 6 When the installation is complete click Finish Tip Some Microsoft components may require a restart before the full CCW installation is complete If Connected Components Workbench does not install completely restart the computer and then re install CCW After the Connected Components Workbench installation completes the computer background will return to its default setting Current Program Updater In order for the Current Program Updater to work seamlessly you must invoke the Current Program Updater software at least once after installation and configure it Follow these steps to configure the Current Program Updater If your user account is an administrator account 1 Close this instance of Current Program Updater right click the Current Program Updater shortcut and choose Ru
3. The directory is lt Root of the DVD media gt 7 00 00 CCW Firmware PVC_Firmware For the absolute latest firmware you can download the latest PanelView Component firmware from the following location hetp ab rockwellautomation com Graphic Terminals 27 1 1C PanelView Component C400 Terminals tab6 http ab rockwellautomation com graphic terminals 27 1 1 p panelview plus 6 terminals Note This latest firmware v1 80 is required to use new features such as the enhanced Download function which can be used to download to your PVc terminal from CCW Components installed with Connected Components Workbench The following additional components are installed with Connected Components Workbench Standard and Developer Editions However these components will not be removed if you uninstall Connected Components Workbench because other software may be using them Type Includes ControlFlash 12 00 01 Rockwell Windows Firewall Configuration Utility 1 00 Rockwell Automation USB CIP Driver Package x86 or Rockwell Automation USB CIP Driver Package x64 RSLinx Classic 3 70 00 Unified Device Configuration v3 10 0 Current Program Updater Microsoft NET Framework 4 Client Profile Microsoft NET Framework 4 Extend Microsoft NET Framework 4 Multi Targeting Pack Microsoft SQL Server 2008 R2 Management Objects Microsoft SQL Server System CLR Types Microsoft Visual C 2008 Redistributable x86 9 030729 Microsoft Visual C 2010 X86 Runt
4. To obtain the latest drivers and firmware updates Go to http www rockwellautomation com rockwellautomation support For the latest Rockwell Automation product compatibility information Connected Components Workbench has been tested to interoperate with most Rockwell Automation software For the latest information about software platform support Go to http www rockwellautomation com rockwellautomation support pcdc page For the latest drivers and firmware updates Go to http www rockwellautomation com rockwellautomation support Rockwell Automation Software Compatibility This release has been successfully tested with the Rockwell Automation software products listed in the following table Software Tested Version RSLinx Classic V3 70 00 ControlFLASH V 12 00 01 RSLinx Classic Compatibility Requirements RSLinx Classic v3 70 00 which is included with Connected Components Workbench is not compatible with the following product versions e RSNetWorx v9 00 or earlier e DeviceNet Tag Generator v11 0 or earlier RSNetWorx Compatibility Requirements If an incompatible version of RSNet Worx v9 00 or earlier is detected during installation the installation will not continue You will need to either remove the incompatible version or upgrade RSNetWorx v21 00 or later RSNetWorx Compatibility Product Notice The current version of RSNet Worx v9 00 and Prior Incompatibility with Rockwell Automation Software Product
5. access the networks to ensure optimal system performance you may need to disable network adapters If you use Connected Components Workbench with VMware you may have to manually connect USB devices When a virtual machine is running its window is the active window and a USB device is plugged into the host computer the device automatically connects to the guest instead of the host This autoconnect feature can be disabled in the USB Controller panel of the virtual machine settings editor VM gt Settings If all of the virtual machine s USB ports are already occupied when it is trying to connect automatically to a new device a dialog box gives you a choice you can either disconnect one of the existing USB devices to free its port or ignore the new device allowing the device to connect to the host Manually connecting a virtual machine to a USB device Choose VM gt Removable Devices to connect specific USB devices to your virtual machine If the physical USB devices are connected to the host computer through a hub the virtual machine sees only the USB devices not the hub There is a menu item for each of the USB ports Move the mouse over one of these items to see a cascading menu of devices that are plugged into your host computer and available for use To connect a device to the virtual machine click its name If a device is already connected to that port click the name of a new device to release the first device and connect the new on
6. containers in the project e Jt does not find all instances of the same Array element variable in all the programs within a project Workaround To find items in the project click Edit gt Find and Replace gt Quick Find and click Current Document or All Open Documents in the Look In drop down box The Quick Find and Quick Replace features will be enhanced in a future release APBC00011079 APBC00011080 APBC00011462 If the appearance settings in your operating system uses a high contrast color theme some workspace elements will display incorrectly For example ladder rungs and connectors in the program editors graphics and toolbar in the Controller Details view and the Device Toolbox APBC00011574 APBCO001 1577 APBC0O001 1578 Workaround Do not use a high contrast color scheme If you select View gt Document Overview while in the Structured Text language editor the Document Overview displays a blank page APBC00004685 Controllers and devices If the Micro800 controller has 7 0 or pre 6 0 firmware and is password protected by CCW7 0 you cannot connect to the controller with a Connected Components Workbench Version that is 6 0 or lower Access is denied even when the correct password is provided Workaround Clear the controller s password by CCW7 0 If the Micro800 controller has 7 0 or pre 6 0 firmware and is password protected by CCW6 0 or lower you cannot connect to the controller with a Connected Components Workbench
7. module e 2080 OW4I plug in module Report Generation Printing a report is available from the logic editor 440C CR30 SensaGuard Safety Monitoring Function The SensaGuard non contact switches provide flexible programmable safety for personnel and equipment for all safety applications The Safety Monitoring Function Block is designed specifically to control the switch and is included in the Toolbox System Requirements Hardware Requirements To use this release of Connected Components Workbench effectively your personal computer should meet the following minimum hardware requirements Component Minimum Requirement Processor Intel Pentium 4 2 8GHz or equivalent RAM memory 2 GB Hard disk space 10 GB free Optical drive DVD ROM Pointing device Any Microsoft Windows compatible pointing device Operating System Requirements This release is supported on the following operating systems e Microsoft Windows 7 32 bit and 64 bit e Microsoft Windows 8 and 8 1 32 bit and 64 bit Recommended Intel Core 15 2 4GHz or equivalent 8 GB or more 10 GB free or more DVD ROM Any Microsoft Windows compatible pointing device Note Not recommended for use with the Micro810 due to USB Adapter driver Driver will be updated in Release 8 e Microsoft Windows 2008 R2 Additionally Internet Explorer which is installed with the operating system is required to view the Connected Components Workbench help Securi
8. Communication Diagnostics view monitors and displays real time statistics for the controller s Ethernet or Serial ports Communication Method Statistics Displayed Ethernet Ethernet Link Status Interface Counters Media Counters CIP Serial Diagnostic Counters Modbus RTU Link Counters The CIP Serial and Modbus RTU views will display statistics for either the controller s embedded serial port or for the 2080 SERIALISOL plug in module Micro810 LCD Variable Display From the Controller tree of Micro8 10 click Remote LCD to select program variables that can be monitored from the 2080 LCD main menu No programming is required Micro800 Lost Project or PC Replaced Enhanced support for cases where the original project is lost or the PC has been replaced and the project is required to be uploaded and then debugged without changing the value of variables Now you can discover the project from the controller and go directly into debug without having to re download the project Note that when a controller is discovered or project uploaded it will automatically update the project with the latest hardware configuration that is detected If new hardware is detected any newly generated I O variables will not be able to be monitored since the I O variables did not exist in the original project 440C CR30 Enhancements to Workspace The Guardmaster 440C CR30 Safety Relay workspace has several new enhancements Feature Description Back
9. Connected Components Workbench Release Notes Release 7 00 September 2014 Contents Support Information New Features and Enhancements System Requirements Working with Projects in Connected Components Workbench Installation and Upgrades Helpful Resources Important Considerations Resolved Anomalies Known Anomalies Application Notes Support Information For technical information and assistance about Connected Components Workbench CCW Support phone 1 440 646 3434 Website http www rockwellautomation com support For information about additional support options you can access from the Help menu see Helpful Resources New Features and Enhancements Workbench Automated Update Notification Using Current Updates Monitor if enabled an automatic notification will occur when a new Connected Components Workbench release is available Automatic update is not supported so you must either download or order a DVD upon receiving the notification Workbench Sample Code and Projects Folder As part of the installation essential Rockwell Automation and partner developed sample projects sample code and User Defined Function Blocks UDFBs are installed into a public folder No need to download from the sample code website To access the folder use the Help menu and select Sample Code gt Local Folder Micro800 and PanelView Component Usability Enhancements This release includes the following usability enhancem
10. Failed to find or create a project for the device e The catalog failed to match the selection to a provider To access CCW projects on a network PC Sharename If you are using a network PC Share name establish a Full Trust relationship with the PC and the shared location For detailed information see Microsoft KB article http support microsoft com kb 320268 To establish a trust relationship excerpt from the KB article Use the following command shell Start Menu Run cmd command to establish the needed trust relationship drive_letter WINDOWS Microsoft NET Framework v2 0 50727 caspol exe m ag 1 url file network_pc_name share_name FullTrust exclusive on For example C WINDOWS Microsoft NET Framework v2 0 50727 caspol exe m ag 1 url file A devlabpc CCWinstall FullTrust exclusive on Connected Components Workbench sample projects This release includes several Micro800 controller sample projects that are installed with Connected Components Workbench in one of the following folders Users current user Documents CCW Sample Projects VMWare compatibility Compatibility with VMware has not been formally tested but it has been used extensively with Connected Components Workbench e Ifyou experience poor performance using VMware with a Window 7 guest you may need to upgrade VMware or run Connected Components Workbench on the host operating system Connected Components Workbench and other software may try to
11. Version that is 7 0 Access is denied even when the correct password is provided Workaround Clear the controller s password by CCW6 0 or lower APBC00022232 When you re launch Connected Components Workbench after an unexpected shutdown the Micro800 controller might be locked and you will be unable to connect to it from the Connection Browser APBC00021900 Workaround The recommended solution to clear the lock on the controller is to restart Windows and the controller The second option is to 1 Terminate CCW Shell exe and RA CCW CommServer exe 2 Shutdown RSLinx and restart RSLinx 3 Restart CCW and try to connect to the controller the connection may still fail 4 Restart CCW and RSLinx and try again the connection should be established If you remove all the characters in the Name text box in the Controller Configuration pane you might receive the following error message Controller name cannot be empty even though you may be about to enter a name APBC00011369 When you configure an Event Input Interrupt EI you can specify which input to use from the Configure Event Input Interrupt EID dialog box You cannot however specify the edge triggering type rising or falling edge from the same dialog box APBC00005579 Workaround To specify the EII edge triggering type rising or falling edge click Embedded I O in the controller tree and configure the Properties in Input Latch and EII Edge You cannot view or configure
12. as a data type The maximum number of words for the MSG_MODBUS ElementCnt parameter is 123 even though the LocalAddr specifies 125 words If you use a value of 124 or 125 for the ElementCnt you will receive an error indicating a bad MSG file parameter exists APBC00003889 Workaround Verify the ElementCnt variable uses a value of 123 words or less If you use single quotes in a variable within an array element even when the data type is String the build may fail APBC0001 1206 Workaround Do not use single quotes in array element variables The allocated memory for a Micro800 controller is not retained on the Memory configuration page after a Controller Change or Export Import project APBC00021196 The allocated memory value is not retained when you upload APBC00021722 Data types and variables User defined global variables with data types BYTE WORD LWORD and DWORD might display as USINT UINT ULINT and UDINT data types on LCD displays for Micro800 controllers APBC00020820 If you use constant values in arithmetic expressions unexpected build errors may occur for the following data types e DWORD e LWORD e INT e SINT e UDINT e ULINT APBC00021989 Workaround To avoid unexpected build errors use Variables with initial values instead of constant values in arithmetic expressions For example DWORD data length is 0 to 4294967295 e The arithmetic expression 4294967295 0 results in an inaccurate build error e The ari
13. ated under a Standard User OK C Users lt Current User gt Documents CCW Code Snippets OK C Users lt Current User gt Documents CCW Settings CCW CCWSettings vssettings OK C Users lt Current User gt Documents CCW Project1 etc OK C Users lt Current User gt Documents CCW Templates OK C Users lt Current User gt Documents CHMI_01 Note It is recommended that Connected Components Workbench is installed on a user account with administrator privileges APBC00012930 Resolved projects documentation and tools anomalies If you click a hyperlink on the MSP module page on a computer that does not have IE Explorer installed Connected Components Workbench will continue to respond and operate normally APBC00019002 If you customize the grid columns in a variable grid and then select Save as default layout settings the settings will be reset after you click Tools gt Import and Export Settings and select the No just reset settings overwriting my current settings option APBC00016798 The Tools gt Execution Order feature is available and works properly on a program that is password protected APBC00018113 Context sensitive help is available for all elements in the Structured Text editor APBC0001 1459 If you use the Document Generator to create documentation for Programs POU that contain large Ladder Diagrams the generated document will correctly display the picture of the Ladder Diagram APBC00013865 Resolved in
14. ccount and that you do use the same type of account you used when you installed Connected Components Workbench That is if you were logged in under an administrator account when you installed CCW you should log in with an account that has administrator privileges when you use Connected Components Workbench To change to an administrator account 1 Navigate to Program Files gt Rockwell Automation gt CCW 2 Right click CCW Shell exe select Run as select Administrator user 3 Click OK To create a new Guest user account 1 Open the New User dialog box e Microsoft Windows 7 Professional Click Control Panel gt Administrative Tools gt Computer Management gt Users 2 Right click Users and then select New User 3 Inthe New User dialog box enter the new user name and password and click Create 4 Click Groups to display the group types 5 Double click the Guests group to open the Guest Properties dialog box 6 Click Add and enter the location and name information for the new user you created in previous steps 7 Click Check Names to verify the information is correct 8 Click OK to add the new guest user to the Guest group 9 Click OK to close the dialog box Localized versions of Connected Components Workbench Some features within CCW may only appear in English even in the localized versions of the software For example the DeviceLogix editor which is used for PowerFlex drives is only available in English
15. close unexpectedly If you recently started the debugger ensure you stop it before performing other software operations e Connected Components Workbench does not automatically update every instance of a changed UDFB User Defined Function Blocks referenced in an existing program If you change a UDFB definition you should update each individual instance of the UDFB To do so locate each instance double click it and then build the program Uploading download and building e When you build a controller project with Connected Components Workbench all changes are immediately committed to your hard drive or to your designated storage device so you will not be able to undo any changes To ensure you can return your project to a prior state save the project using a different name after making changes e Ifthe Upload or Download options are not available in the Device Configuration toolbar select the Micro800 controller from the Project Organizer and then click Upload or Download If this does not activate upload download rebuild the project by right clicking the controller in the Project Organizer and selecting Build Resolved Anomalies This section identifies anomalies that have been resolved since the last release of Connected Components Workbench Installation Connected Components Workbench allows you to install on a Microsoft Windows operating system using an account that does not have administrator privileges These items are cre
16. e To release a connected device click None on the cascading menu for the port to which it is connected If you physically plug a new device into the host computer and the autoconnect feature does not connect it to a virtual machine the device is initially connected to the host Its name is also added to the VM gt Removable Devices menu so you can connect it to the virtual machine manually Copyright 2014 Rockwell Automation Technologies Inc All rights reserved Connected Components Workbench Release 7 00 September 2014
17. e variables Project Values can also be manually edited in the project Project Values are similar to Initial Values when downloading except that Initial Values must be manually entered in the project A new Download Confirmation dialog appears during the Download process asking if you wish to Download or Download with Project Values e Selecting Download initializes variables with Initial Values e Selecting Download with Project Values initializes variables with Project Values If both Project Value and Initial Value exist for a variable then Initial Value has precedence Micro800 Variable Export Import Global and local variables can now be exported to and imported from Microsoft Excel spreadsheets This is an easy way to edit a large number of variables or transfer variables between multiple projects Because of the formatting requirements for importing variables from an Excel spreadsheet it is recommended to export variables to Excel first and then edit the Excel file rather than creating variables from a blank spreadsheet The Export Variables Only checkbox has been removed from the Import Export dialog box Variables can only be exported to compressed files as part of a controller program or user defined function block Variables that were exported to compressed files using a previous version of Connected Components Workbench can be imported using the Import Export dialog box To view the Variable Export Import dialog box for g
18. ents Interface Element Description of Updates Since Previous Release Windows and dialog boxes Upload Download Icons The Micro800 Upload Download icons are now consistent with other devices Up arrow indicates upload and down arrow indicates download Project Organizer Programs can be dragged and dropped within the Project Organizer to change their execution order The following items have been added to the right click menu Connect Diagnose Secure Variable Export Import Data Protection Document Generator print The icons for the Programs and User Defined Function Block groups have been updated An Interrupt icon is now shown when an interrupt is assigned to a program Device Menu Connected Components Workbench now has a context sensitive Device menu for accessing commonly used functionality The Device menu contains the following items Build Connect Download Upload Diagnose Secure Change Controller Import Export Data Protection e Document Generator print Download Downloading the project to the controller will automatically Build if the project has changed since the last Download When downloading the project to a Micro820 Micro830 or Micro850 controller a new Download Confirmation dialog appears asking if you wish to Download or Download with Project Values See the Data Upload Download feature below for more information Variable Grid The Attribute column has been hidden by default It can be shown by ri
19. ermissions to the network folder the following error might appear Error 1325 FolderName is not a valid short file name APBC00021544 Connected Components Workbench installs two folders named CCW under Libraries gt Documents The duplicate folder name is inaccurate because the folders contain different files One folder contains saved project files and the other contains Sample Project files APBC00021599 The first time you launch Connected Components Workbench after installation if you open two or more instances of CCW at the same time the following error might occur License is expired the product has returned to the Free Version APBC00020976 Workaround When launching Connected Components Workbench for the first time do not open multiple instances If this occurs you must uninstall and then re install Connected Components Workbench When starting Connected Components Workbench it may hang and a stopped working dialog will appear Occasionally some of the layout settings may be corrupted affecting editing and monitoring variables because the initiation process was interrupted Due to performance issues this occurs mostly on VMware machines or when starting Connected Components Workbench for the first time after installation APBC00022659 Workaround If this occurs reset the Layout settings in Connected Components Workbench e From the Tools menu select Import and Export settings e Select Reset all settings and click Next
20. ersion of Connected Components Workbench Standard or Developer Edition 2 Uninstall the previous version of Connected Components Workbench from your computer 3 Launch Setup exe 4 Follow the prompts in the Connected Components Workbench Setup window 5 optional If installing the Developer Edition enter your serial number into the installer when prompted Note Connected Components Workbench determines the correct components to upgrade 6 Click Finish when the upgrade is complete 7 Ifyou are prompted to select Online or Local Help the first time you launch the Help select Local 8 Ifyou want to use the most current features on projects created in previous versions of CCW follow the steps in Converting an existing project to the current release Opening existing projects An existing project that is converted to the current release or opened and saved in the current release or downloaded to a Micro800 controller cannot be opened in a previous release If a project is shared all users must upgrade to the current release of Connected Components Workbench to continue using the project Converting an existing project to the current release When you open a project that was created in a previous release of Connected Components Workbench the project database is automatically updated to the current release However to use new features associated with the current release you must use the Change Controller feature to update the contr
21. expected Programs In Connected Components Workbench R6 and R7 Defined Word Const0 is incompatible with all data types on compare instructions APBC00022224 Ladder Diagram programs if you assign variables by name to an instruction but the variables do not exist yet a yellow triangle appears as expected When you create the global or local variables and build the program the build succeeds However the yellow triangle remains in the instruction until you re assign the variables to the instruction in the Ladder Diagram program APBC00019976 If you use a Remote Desktop Connection to access a CCW program the font for some of the comments in the program may change and be difficult to read APBC00017812 Workaround Double click the comment to restore the original font When the Recipe function block continuously writes recipe data files to the Recipe sub folder the number of files created may exceed the maximum allowed limit of 50 files Workaround See the Micro820 controller user manual for more information about maximum limits The manual is available from Help gt User Manuals gt Controllers gt Micro820 APBC00017884 If you use the AWT command to send characters when the RX receive buffer is empty the characters will not be sent APBC00017012 Import and export If you import a file containing Toolbox settings using the Import and Export Setting Wizard and the project contains an LD program the LD Toolbox may not show it
22. ght clicking on the header and selecting Show Column gt Attribute When viewing variables in Debug mode using a Micro820 Micro830 or Micro850 controller the Initial Value column is moved left so that it is next to the Physical Value column When viewing variables in Offline mode using a Micro820 Micro830 or Micro850 controller a new column Project Value has been added See the Data Upload Download feature below for more information Micro800 Controller The Micro800 Controller Configuration page additions changes and removals Configuration pages e General e Memory page now with enhanced memory diagnostics on instruction and data usage e LCD Module e Startup includes Diagnose button e Startup Faults removed Serial Port includes Diagnose button for CIP and Modbus RTU Driver selections e Ethernet includes Port Settings and Diagnose button e Port Settings removed e Internet Protocol removed e Port Diagnostics removed Real Time Clock Date and Time removed Memory Card includes Diagnose button Plug in Modules 2080 MEMBAK RTC Plug in Modules 2080 SERIALISOL Ladder Diagram Editor e Horizontal space optimized by making labels hidden by default and moved above the comment e Improved readability by removing the color gradient background e More flexibility in customizing the rung s visual properties Right clicking rung provides an easy way to reset back to defaults Function Block Editor Function Blocks can be aligned to one an
23. gine Execution Time 2 Save the project 3 Delete the Axis and then save the project again 4 Re build the project If you change the interrupt assigned to a program Connected Components Workbench does not calculate a new CRC for the program When you attempt to debug a program where only the interrupt has changed Connected Components Workbench displays a project contents mismatch error instead of a CRC mismatch error APBC00021071 Complex variables function blocks and instructions that contain members with initial values do not download their logical values to the controller The following instructions contain read only initial values and are affected by this anomaly AWA AWT COP HSC IPIDCONTROLLER MSG_CIPGENERIC MSG_CIPSYMBOLIC MSG_MODBUS MSG_MODBUS2 PLUGIN_READ PLUGIN_WRITE APBC00021172 APBC00021254 Looe Instructions with a USINT input parameters have the following issues e Debugging these instructions the USINT input parameters show WAIT e Uploading data values warning message shows for instructions with USINT inputs and their logical values fail to upload The following instructions have USINT input parameters MSG_CIPGENERIC MSG_CIPSYMBOLIC PLUGIN_READ PLUGIN_WRITE DLG MUX4B MUX8B RCP MC_AbortTrigger MC_TouchProbe APBC00022484 If you download a project to a controller then upload the project to a computer where the date and time is prior to the date and time on the first computer t
24. he second computer cannot Debug or Download to the controller APBC00021719 Workaround Follow one of the following steps to resolve the error e Set the date and time of the second computer to be equal to or later than the first computer e On the first computer export the project to a compressed file then import the project on the second computer Restore from memory and Load always functionality are contradictory When a controller in Connected Components Workbench is not password protected and Memory module is password protected the Restore from Memory Module button is unavailable because of a password mismatch However if you power cycle the controller and Load always is enabled for the controller the program is transferred to the controller APBC00021421 Application Notes Repairing Visual Studio Service Pack 1 If Connected Components Workbench is installed on a computer on which Visual Studio 2010 Service Pack 1 was previously installed you may receive an error message when you start Connected Components Workbench If this occurs follow these steps 1 Close all Visual Studio products 2 Install Visual Studio 2010 Service Pack 1 3 Ifthe Setup starts in Maintenance mode select Repair Maximum number of parameters for a UDFB If the project contains a UDFB with too many total parameters you might receive a build error even though the total number of input and output parameters seems within range This can happen becau
25. ill be assigned IP addresses that will allow them to communicate using this Ethernet IP driver The Ethernet IP driver will browse for all devices on the subnet In cases where the device is not on the same subnet as the PC or you do not wish to view all devices on the subnet you will need to install the Ethernet Devices driver which requires manually entering the IP address of the device To add the Ethernet driver to connect to a device Follow these steps to add the Ethernet Devices driver 1 Click Communications gt Configure to open the Configure Drivers dialog box 2 In Available Driver Types select Ethernet Devices 3 Click Add New and type a name for the driver or accept the default name 4 If prompted enter the Ethernet adapter selection Note If connecting using CATS5 style cabling be sure to select the correct port it may not be the Windows default 5 For each device enter the IP address under Host Name Click Add New as necessary Click OK and Close when finished 6 For the device click Connect to open the Connection Browser 7 Expand the Ethernet Devices driver you previously added 8 Select the controller that you want to connect to from your project 9 Click OK Accessing projects remotely If you create or open projects on a remote mapped drive or on a network PC Sharename you may receive any of the following Catalog errors unless you configure remote access for the computer e IDF Catalog Error e
26. ime 10 0 40219 Microsoft Visual Studio 2010 Shell Isolated ENU Microsoft Visual Studio 2010 SP1 e Microsoft Visual Studio 2010 Tools for Office Runtime x86 Microsoft Visual Studio 2010 Service Pack 1 Microsoft other e MSXML 4 0 SP2 Parser and SDK Microsoft Help Viewer 1 1 Microsoft SQL Server Compact 4 0 8482 1 OPC Core Components Redistributable x86 101 2 or OPC Core Components Redistributable x64 101 2 Virtual COM Port Device Driver 6 3a Adobe Reader 11 0 Rockwell Automation Microsoft NET Framework Microsoft Visual Studio 2010 Isolated Shell ENU Other Connected Components Workbench Developer Edition Only FactoryTalk e FactoryTalk Activation Manager v3 60 00 CPR 9 SR 6 e FactoryTalk Diagnostics v2 60 00 CPR 9 SR 6 Helpful Resources User assistance available in the application Use the Help menu to access online information such as user manuals user forums support e mail and the Rockwell Automation Knowledgebase Click F1 to open a topic specific to the user interface item you have selected Tips Ifthe user interface item does not display a topic click Help gt Search and enter a subject in the search box to locate a relevant topic in the help e Connected Components Workbench uses local help only If the Online Help Consent dialog box appears when you press F1 click No and verify the I want to use local help option is selected Accessing Rockwell Automation support websites With the exce
27. lobal variables e Inthe Project Organizer right click the controller then click Variable Export Import To view the Variable Export Import dialog box for local variables e Inthe Project Organizer right click a program or user defined function block then click Variable Export Import Micro800 Network Diagnostics Connected Components Workbench CCW provides diagnostics for network connectivity controller startup settings controller faults and controller projects stored in memory The Device menu has options to diagnose the operation of Controller startup Serial port connection e Ethernet connection e Memory card e LCD module e 2080 SERIALISOL plug in module e 2080 MEMBAK RTC plug in module The diagnostics in CCW have been enhanced to include three separate diagnose views Diagnose View Description Controller Allows you to compare the configuration settings of the current project and the connected controller including controller startup Memory Module Memory Card and LCD Module Fault Allows you to view the status of the controller information about any faults that occur and to retrieve a detailed fault log Communication Allows you to display real time statistics for the controller s Ethernet or Serial ports To open the Network Diagnostics e Open the controller in the Project Organizer e Connect to the controller e Click the Diagnose button e Select either Controller Fault or Communication The
28. n as administrator 2 Run the updater as you normally would and Current Program Updater will automatically correct any missing permissions The next time you run it you may revert back to running the standard way If your user account is a standard account you will require the assistance of an IT person with administrator login credentials 1 Close this instance of Current Program Updater right click the Current Program Updater shortcut and choose Run as administrator 2 Have your IT contact enter the administrator password 3 Run the updater as you normally would and Current Program Updater will automatically correct any missing permissions The next time you run it you may revert back to running the standard way Note The Current Program Updater only updates permissions on directories of applications that are being updated This will not affect applications not related to Current Program Updater Upgrading to the current release of Connected Components Workbench Follow these steps to upgrade a previous release of Connected Components Workbench to the current release Before you begin e Record device configuration information related to Modbus mapping Interrupts Serial Port settings and Embedded I O for all existing projects e Ifupgrading from Standard Edition to Developer Edition have your Developer Edition serial number ready To upgrade to the current version of Connected Components Workbench 1 Download the current v
29. n of Connected Components Workbench that is different from the one currently or previously installed To install a different language edition of Connected Components Workbench Important Remove CCW before you remove Microsoft Visual Studio Shell or you will not be able to remove CCW 1 Uninstall the previous language edition of Connected Components Workbench from your computer 2 Verify Connected Components Workbench does not appear in the list of installed programs 3 Remove the previous language edition of Microsoft Visual Studio Shell 2008 Service Pack 1 4 Download the desired language version of Connected Components Workbench Standard or Developer Edition 5 Launch Setup exe to begin installing the desired language version of Connected Components Workbench and Microsoft Visual Studio Shell 6 Follow the prompts in the Connected Components Workbench Setup window 7 When the installation is complete click Finish Upgrading to the latest PanelView Component firmware PanelView Component DesignStation which can be used to create configure and monitor Graphic Terminal devices is installed with Connected Components Workbench and can be accessed from the Project Organizer after you add a Graphic Terminal device An upgrade of your Panel View Component terminal s firmware is not required but is recommended and may be needed for newer features The Panel View Component firmware is located as part of the installation media
30. nd then reopen the project APBC00015937 Workaround In your operating system select the language version of non Unicode programs that will be used in the Language for non Unicode programs If you open multiple projects on a network drive using File gt Recent Projects and then exit or close CCW the application may not close immediately APBC00014847 Content for the instruction block tooltips and in the Category and Comment columns of the Instruction Block Selector appear in English in the non English versions of Connected Components Workbench APBC00013270 APBC00012607 If you add a Block element to a Program POU in the non English versions of Connected Components Workbench rename the POU in the Project Organizer and then click Save or Build a Detected modification error may appear APBC00013784 Workaround Close the error dialog and continue The labels for Browse and No header or footer in the Document Generator for the non English versions of Connected Components Workbench may be truncated For example the label Durchsuchen appears as Durchsuche APBC00013944 The Quick Find and Quick Replace features Ctrl F and Ctrl H are limited to logic editor They do not work with devices global variables or UDFBs Additionally Quick Find has the following limitations e It does not find any items when the Look In selection is Current Project or Entire Solution e It may not locate all instruction blocks within all
31. nstance and view the Scr and Dest input values as they update do not assign a variables to the COP inputs If you import a user defined function block into a password protected program that already contains an instance of the same UDFB you will not be prompted to enter the program password even though the UDFB instance in the program will be replaced by the newly imported UDFB instance APBC00018245 If you rename a user defined function block instance that is referenced in a program and then build the controller project the following error message appears A function function block or operator is not defined UDEB instances must have the same definition to successfully build the controller project APBCO00016939 Workaround Open the program and reselect the UDFB In a Function Block Diagram program if you connect the output of an ANY_TO_WORD operator to the input of a UDFB the compiler will display a false positive error that the data types do not match APBCO0005062 Workaround Use an intermediary variable to transfer a value between the instructions After building a program that uses an ANY_TO_WORD ANY_TO_DWORD or ANY_TO_LWORD operator that does not have the correct data type defined for the output variable you might receive the following error message Expecting a UINT type variable even though the output parameters all use a WORD data type APBC00007106 Note The error message should state that a WORD type variable is
32. oller firmware revision For the specific firmware revisions that can be used for each controller type see the Micro800 firmware revision compatibility section in System Requirements To convert an existing project 1 Open the existing project in the current version of Connected Components Workbench 2 Recommendation Record device configuration information related to Modbus mapping Interrupts Serial Port settings and Embedded I O for the project 3 Use the Change Controller feature to update the controller firmware revision 4 Ifnecessary manually reconfigure Modbus mapping Interrupts Serial Port settings and Embedded I O for the project Note Modbus mapping information is stored in the MbSrvConf XML file located in the CCW project structure CCW lt projectname gt controller controller and can be copied from the original project to the newer one Removing Connected Components Workbench Follow these steps to remove Connected Components Workbench only For other components remove each component separately after removing Connected Components Workbench 1 Uninstall Connected Components Workbench from your computer 2 Verify Connected Components Workbench does not appear in the list of installed programs 3 Remove other components as necessary See Components installed with Connected Components Workbench Installing a different language edition of Connected Components Workbench Follow these steps to install a language editio
33. other at their top bottom left and right edges as well as aligned with their vertical center and horizontal middle axes The background grid has been removed PanelView Components The PVc Help is now part of the Connected Components Workbench Help DesignStation Micro800 Data Protection Data Protection for Micro830 and Micro850 controllers allows you to create a list of user defined global variables whose logical values are not overwritten when restoring a controller project from a memory module Key process variables can be preserved even if a new project is restored into the controller To configure Data Protection e From the Project Organizer right click the Micro800 controller and select Data Protection e Add the global variables to the list using the Data Protection dialog box Micro800 Retained Timer Instruction Function Block Description RTO The RTO function block is a retentive timer It increases an internal timer when its input is active but does not reset its internal timer when its input changes to inactive Micro800 Data Upload Download When working with a Micro820 Micro830 or Micro850 controller you can set Project Values for all global and local variables When uploading Project Values are automatically updated with the current Logical Values for the variables and can be saved permanently if project is saved When downloading Project Values can be chosen to initialize the logical values of th
34. parameters for Micro810 LCD modules within Connected Components Workbench APBC00005458 Workaround To configure LCD module setup parameters e Download the program to the controller e Configure the setup parameters using the LCD module e Upload the program to Connected Components Workbench e Save the program While in PanelView if you create decimal values while the regional setting is set to English and then change the setting to Spanish the PanelView Component incorrectly displays integer values APBC00005484 APBC00005485 Workaround Change the regional settings before making any application changes In the Variable Editor when viewing a user defined function block that contains multiple nested functions or function blocks the nested variables may not align correctly within the Logical Value column If you hide the Logical Value column and then show the column it is moved to the rightmost position in the Variable Editor and the values for the nested variables may not show in the column APBC00014339 If you create a string array using the Global Variables grid the maximum length is 252 characters If you create a string array using the Data Types grid the maximum length is 255 characters APBC00010227 Workaround Make all string arrays 252 characters or less The SAFEBOOL data type appears as an option in the Arrays grid but SAFEBOOL is not supported by Micro800 controllers APBC00010414 Workaround Do not select SAFEBOOL
35. pecifications e Safety relay user manual e Non English language versions of user manuals To access manuals from the Rockwell Automation Literature Library 1 Goto http literature rockwellautomation com 2 Click Advanced Search 3 Enter the product information and other search criteria and click Search To access the non English language versions of user manuals 1 Goto http literature rockwellautomation com 2 Select the language from the Publication Language drop down box right corner 3 Enter the full or partial device catalog number in the Search box For example enter 2080 LC30 to view Micro830 user manuals Important Considerations EC 61131 standards Connected Components Workbench adheres to the IEC 61131 standards for programming If you do not have previous experience with IEC style concepts and programming we recommend you view the Getting Started with Developing section in the software help The topics which step you through the process of creating a basic sample application are intended to introduce you to IEC style programming within the Connected Components Workbench environment Programming configuring and debugging e Unless specifically stated in user documentation do not change attributes in Property dialogs for Micro800 controllers e Some features that should be disabled appear available while the debugger is operating A small subset of these features may cause Connected Components Workbench to
36. ption of manuals you must register Become a Member to access free of charge Rockwell Automation support websites Register at http ab rockwellautomation com Rockwell Automation Knowledgebase The Rockwell Automation Knowledgebase contains product notices technotes and FAQs that you can access after you log into the Knowledgebase To access articles from the Rockwell Automation Knowledgebase 1 Goto http www rockwellautomation com rockwellautomation knowledgebase 2 Login 3 Enter the article ID for example 116930 in the Search box Knowledgebase articles Article ID number Micro800 basic FAQ Answer ID 116930 https rockwellautomation custhelp com app answers detail a_id 1 16930 Micro800 extended technical FAQ Answer ID 1188115 https rockwellautomation custhelp com app answers detail a_id 1 18815 Security considerations when using Rockwell Automation Software Answer ID 609492 Products https rockwellautomation custhelp com app answers detail a_id 6 09492 RSNetWorx v11 and Prior Incompatibility with Rockwell Product Notice ID 56697 Automation Software Products https rockwellautomation custhelp com app answers detail a_id 5 66967 Rockwell Automation Literature Library You can view or download publications from the Rockwell Automation Literature Library including the following e PanelView Component DesignStation Release Notes 2711C RN0O10 EN E e Kinetix 3 user manuals e Kinetix Rotary Motion S
37. s controls after the import Instead the LD Toolbox will show the text There are no usable controls in this group Drag an item onto this text to add it to the toolbox APBC0002053 1 Workaround Right click the Toolbox and select Reset Toolbox In the Import and Export Setting Wizard if you reset all settings and select the option No just reset settings overwriting my current settings some items may not appear in the File and Help menus as expected APBC00015185 Workaround If this happens follow these steps 1 Save your project 2 Close and reopen Connected Components Workbench to display all the menu items If while importing variables into a password protected POU you click Cancel in the Enter Password dialog box the import will be canceled which is expected behavior However you still may receive an Import was successful message in the output window which is incorrect APBC00016089 If you try to Import a Micro800 program that contains a password and the program is not compatible with the version of Connect Components Workbench that you are using the Password required dialog box appears After you enter the password the Unable to start importing dialog appears APBC00014022 If you import a POU that contains an instruction that is not supported in the target Micro800 project you will receive an error when you build the project which is expected behavior However if you double click the error item it will not navigate
38. s is available from the Rockwell Automation Support Center as Product Notice ID 56697 Upgrading RSNetWorx If you are under a current technical support contract you may download RSNet Worx v21 from the Rockwell Automation Compatibility and Download Center To download RSNetWorx e Click the Download Software Updates link and enter your Rockwell Automation Member identification e Enter your Company Name and the Software Serial Number for your current RSNetWorx e Follow the instructions to download and install the updated software product If you are not under a current technical support contract you may purchase an update for RSNet Worx by contact Rockwell Automation sales Note RSNetWorx v21 00 is also available in Studio Professional v21 00 Working with Projects in Connected Components Workbench Using existing projects in current release You can open a project created in a previous release without updating the controller firmware or performing a manual project conversion However if you want to use the most current features you must convert the project using the Change Controller feature If you do not update the controller revision to the latest new features will not be available See Convert a project to the current release section in Installation and Upgrades for more information Using different account types When you create new projects or open existing projects we recommend you do not use the default Guest user a
39. s release some of the vendor specific instruction blocks and other program elements have not been identified as reserved words When you name a variable CCW may allow you to name a variable the same as an instruction block even though it should not be allowed When you attempt to build a program with duplicate names the error message will identify the instruction name as the problem rather than the user variable APBC0O0017881 If you name a variable the same as an existing program name you will receive an error when you attempt to build the project You can disregard the error message as a program and a variable can use the same name since they are different object types Duplicate names in this situation will not prevent the project from building APBC00018410 If you attempt to set the Logical Value for a sub element of a data type that contains a nested array structure you may need to click more than once to enable the selection APBC00017133 Instruction blocks If you use the Search option to search and replace content in user defined function block code the replace process continues without stopping APBC00020636 Workaround To stop the continuous Search and Replace process restart Connected Components Workbench If you assign variables to the COP instruction block instance and start debugging the Scr and Dest input values do not update They incorrectly display as WAIT APBC00014533 Workaround To debug the COP instruction block i
40. se the UDFB local variables are included in the total Limit the total number of parameters for each UDFB to a total of 128 Modifying existing UDFBs Connected Components Workbench does not automatically update the instances of the modified UDFBs referenced in existing programs To update every instance of the UDFB search for it and update each one manually MOV instruction and Assignment operator The MOV instruction displays in the Instruction Selector when it is launched from a LD POU or a FBD POU but it does not display ina ST POU ST programs use the assignment operator instead of the MOV function APBC00014308 Connecting to a Micro800 controller on a virtual machine If you install RSLinx Classic on a virtual machine for example VMWare make sure to disable RSLinx Classic on the host computer before you plug the USB cable that is attached to your Micro800 controller into the host computer If you ignore this step the host computer will obtain the driver for the Micro800 controller and the virtual machine may not be able to detect the Micro800 controller Connecting to a Device using the Ethernet IP Driver If you use Ethernet instead of a USB to connect to the controller the Ethernet IP driver is installed by default in RSLinx and you can connect to devices which are on the same subnet as the PC Ifa DHCP server is available in most cases your computer and the device such as Micro850 controller which defaults to DHCP w
41. struction block anomalies After the Key Read function block is triggered its output is reset after the rung goes false You can check the Status bit to verify the output results APBCO00019913 The Enter Password dialog box no longer appears when you are working on a UDFB even though you did not modify the program APBC0001841 1 After completing a successful build a yellow warning icon does not appear on the instruction block APBC00007405 Resolved import and export anomalies If you import a UDFB while an instance variable structure is being viewed the instruction values refresh properly within the language editor APBC00018349 Resolved build debug download and upload anomalies You will not experience any intermittent issues related to removing the SD memory card while it is being accessed by the Micro800 controller APBC00018115 If your program calls nested UDFBs build results appear in the output window when you build the program APBC00018116 If you open a project created in a CCW R2 0 or CCW R4 0 then set the initial value of a UDFB and perform a Refactor operation you will not receive an error indicating the initial value has an incorrect format APBC00017736 Known Anomalies This section describes known anomalies in this release and if needed provides workarounds Installation If the My Documents folder is mapped to a network drive and the user installing Connected Components Workbench does not have full p
42. thmetic expression 4294967295 any Variable with initial value 0 does not cause a build error Include Logical value upon backup and restore functionality does not restore the logical value for the following system variables e _SYSVA_KVBCERR e _SYSVA_TCYCYCTIME e _SYSVA_TCYWDG APBC00021350 APBC00021351 If you attempt to copy and paste a variable that uses an initial value from one open session of Connected Components Workbench to another open session you may receive an error message similar to one of the following and the paste operation will not be successful e Warning The variable you are pasting having the data type aa is non existent in the current project Therefore the variable shall be created as an undefined type e The importation of the symbol Controller Micro850 Micro850 Prog1 v1 was unable to set the field TextInitial Value 1 65 gt Exception Message The value does not match the format of the data type When you copy and paste from one project to another project CCW may not copy all the properties of the object If the new project does not have all the property objects defined such as a data type errors may occur APBCO00018350 Workaround Copy all data type definitions to the project before you copy the variable If you monitor a variable with an array data type the variable may display WAIT for its value APBC00018556 Workaround Use the variable view to monitor the values for the array In thi
43. to the error location in the project APBC00014443 If you import a UDFB program into a project that contains a user defined data structure or array with the same name as the UDFB the project build will fail which is expected behavior However the error message may indicate a FB symbol duplication error which is incorrect APBC00015612 Build debug download and upload If you enter Debug mode after running Connected Components Workbench for an extended period of time a red X may appear in the language editor and you may receive the following error message CCW shell has encountered a problem We apologize for the inconvenience Please tell IsaGRAF about this problem APBC00018407 Workaround If this occurs close the language editor verify you are in Debug mode and then reopen the language editor Note Any message that identifies ISaGRAF as a contact should actually identify Rockwell Automation as the contact See Support Information for contact information If you attempt to build a project that has an invalid Motion Engine Execution Time you will receive a build error which is expected behavior If you then delete the Motion Axis without first correcting the Engine Execution Time and build the project again the build will still fail Note When you enter an invalid value the field is outlined in red indicating an error APBC0001 1576 Workaround Follow these steps to resolve the error 1 Add an Axis and enter a valid Motion En
44. ty Requirements Connected Components Workbench and its included software require running system services and network access to communicate with controllers drives graphic terminals and other devices You may need to enable system services or configure firewall rules in order for Connected Components Workbench to function properly For a list of software installed with Connected Components Workbench see Components installed with Connected Components Workbench in Installation and Upgrades For a list of services that require network access as well as detailed information on security concerns see Knowledgebase Answer 609492 https rockwellautomation custhelp com app answers detail a_id 609492 Security considerations when using Rockwell Automation Software Products Micro800 Firmware Revision Compatibility The following table identifies the major firmware revisions that can be used for each of the Micro800 controller types Controller Type Major Firmware Revisions Micro8s10 1 xxx 2 xxx and 7 xxx Micro820 6 xxx and 7 xxx Micro8s30 1 xxx 2 xxx 4 xxx 6 xxx and 7 xxx Micro8s50 2 XXX 4 XXxX 6 xxx and 7 xxx To view the latest Micro800 controller firmware information See Micro800 Programmable Controllers Release Notes 2080 RN001_ pdf located in the following locations e Release Notes folder on your installation media or e Program Files Common Files Rockwell Help folder after you install Connected Components Workbench
45. up and Restore Allows the backup and restore of the CR30 s configuration with the 2080 MEMBAK RTC plug in module Plug in must be inserted into slot 1 while connected to the CR30 in order to access the backup and restore functions Function Block Name Change Allows changing the name of a Safety Monitoring Function SMF or Safety Output Function SOF block The feature has built in name checking to ensure all function block names are valid Mute Lamp Safety Output Function The default assignment for the Mute Lamp Safety Output Function is a single output terminal The preferred assignment is e First available multipurpose terminal 12 17 with a configuration type as No PT First available terminals 18 21 will take second priority with a configuration default of PT Comparison of downloaded uploaded After a Download Success the downloaded CRC and uploaded CRC are displayed for configuration verification purposes Password Protection Prevents unauthorized access and possible tampering with safety relay programs Input Filters Safety Monitoring Functions e Tooltip Input Filter tooltip for Safety Monitoring Functions Recommends filters never exceed 250 ms e Safety Mat input filter selection limited to a range of 0 8 e Reset input filter removed e Restart input filter removed Plug in Modules The safety relay supports these additional standard I O plug in modules e 2080 IQ4 plug in module e 2080 OB4 plug in