1. and enter IP address 192 168 123 1 Subnet mask 255 255 255 0 Default gateway 192 168 123 1 5 Click OK twice You can now access the unit using your web browser at the permanent IP address of 192 168 123 1 In some configurations leaving the gateway field blank may resolve connectivity issues Version 1 0 11 PViQ Switched POU Internet Protocol TCP IP Properties 12 168 123 1 255 255 255 0 192 168 1233 1 P Obtain ONS server address automatically e Use the following DNS server addres Typical Network Card Settings for PC or Laptop to connect to default IP address 12 Version 1 0 PViQ Switched POU Web Interface Overview The unit is accessible via a standard unencrypted HTTP connection as well as an encrypted HTTPS SSL connection The following web pages are available Sensors Page The front page Sensors gives both instantaneous and historical views of the unit s data Real time readings are provided for all power strip data outlet group data and sensor data next to historical graphs Optional cameras may be added and their live snapshots are shown on this page Plug and play sensors appear below the internal sensors when attached The menu bar allows access to the rest of the POU s functionality an e PViQ POU 1 Switched PViQ POU 1 Switched v3 5 6 DUIT are Ver 10 54 20 Allis well 3 Alarms monitored Sensors Sensors A
2. Actions tab Of Delayed On On Off Off of the Control page m 22 Outlet 23 On 0 00 0 012 T d 23 Qutlet23 On 0 00 0 008 T d 24 Qutet24 On 0 00 0 001 0 Mone On Immediate Execute On Delayed Ot Immediate nit Location Unit Description 00 19 95 Ey Eat Kh Admin or Call Cancel Actions Support Manuals cs panduit com or Call 800 777 3300 Copyright 2003 2010 Panduit Corporation All Rights Reserved Immediate Turns on all selected outlets with no delay Delayed Turns on all selected outlets with applicable delays Immediate Turns off all selected outlets with no delay Delayed Turns off all selected outlets with applicable delays Reboot Cycles power to the selected outlets with applicable delays Cancel Actions Cancels any actions currently in progress on the selected outlets Reset kWh Resets the kWh total on all selected outlets to 0 PViQ per outlet monitoring units only The page at https 1927 166 1 110 says g Are vou sure You want to perform the Following action lt Selected action Reboot gt Outlet 23 Cancel To perform an action select the check box next to the outlets needing attention select an action from the drop down box and click the Execute button A dialog box will appear asking for confirmation of the selected actions Click OK to execute the action Click cancel to make changes or ignore the action v Note Reboot and Del
3. Configuration Sensors Alarms Syslog Logging Facility Display Daemon Address port 1 Config Network Save Changes Monitoring Diagnostics Syslog Configuration Event Log p Admin Seren mm rn warring notice inform debug Control os O d Pi O Help Iwip O O O Pi en socket RW d O d macphy d d d flashfl oO d O O webserv oO d O d spiOdev DW oO O RW device RW O O C host d Pi O O setvars O RW d O dynweb O d d d snmp O d O O alarms O d d Pi email O O O O rtclock O d d C sntp O O Pi O dns O O O O datalog d oO O d graphin P O O firmwar d O O d msgcatlg O d O O Save Changes 22 Version 1 0 PViQ Switched POU Configuration Event Log Tab The user can view the Event Log and update the Memory Syslog settings on the Event Log tab of the Configuration page PANDUIT PYiQ POU 1 Switched IP Address 192 168 1 110 Local Time Wed 12 15 10 11 28 09 PYiQ POU 1 Switched v3 5 6 Allis well 3 Alarms monitored Configuration Sensors Alarms NYRAM Event Log Pr Click here to view NVM event log Display Clear NVM event log Config Network Memory Syslog Monitoring EENEG EE setvars vars from pairs path dyn config eventlog ht A Diagnostics 12 15 2010 16 28 08 setvars vars from pairs got vers config lock 0 field Event Log 12 15 2010 16 24 34 setvars vars from pairs path dyn config diagnostics 12 15 2010 16 24 34 setvars vars from pairs got vars config lock O field Admin 12 15 2010 16 17 16 setvars v
4. 8 4 4 save Changes Web Server Protocols HTTP and HTTPS ze HTTP Port op HTTPS Port 443 Telnet Service Enabled Save Changes Unit Location Unit Description 00 19 85 E0 SD AC Admin or Call Support Manuals cs panduit com or Call 800 777 3300 Copyright 2003 2010 Panduit Corporation All Rights Reserved 20 Version 1 0 PViQ Switched POU Configuration Monitoring Tab The user can enter and update the email alert SNMP and camera settings on the Monitoring tab of the Configuration page See Unit Configuration section for details Dan e PViQ POU 1 Switched PViQ POU 1 Switched v3 5 6 DU IT nP e heca eee ene All is well 3 Alarms monitored Local Time Wed 12 15 10 11 17 17 Configuration Sensors Alarms E mail Logging SMTP Server 192 168 0 1 Display 192 168 0 1 Config SMTP Port 25 Berso From E mail Address Monitoring Dante Business After H Send alarms to this recipient Always Hours Hours SMS Event Log To E mail Address 1 gni testdomain local O O O Admin Control To E mail Address 2 O O DO Help To E mail Address 3 O O Fi PDA Phone To E mail Address 4 Oo XML MIB O To E mail Address 5 O O Oo POP3 Server POP3 Port 110 Username Password Save Changes Business Hours Start Time 99 00 End Time 17 00 Sun Mon Tue Wed Thu F
5. Enable OST Disabled DST Start Ist Gun win Jan at 00 00 OST End 1st e Sun en Feb sat 00 00 Save Changes Name and Password Configuration NOTE i If Account currently hat pasword leaving Old Daciword blank rests in no changes to that account NOTE 2 Administrator password may be used in the Old Password Beki of o account NOTE 3 Jf petting Mew Pastword to blank Account Name must sho be blink NOTE 4 If New Base d a not blank Account Name must not be blank Administrator Account Name Old Password New Password New Password Again ager to confirm Warreng Record your parmword Loss of panzwerd may require lt 3 hours te recover Control Account Name Ok Password New Password New Password Again agan to confirm Wartung Record your parswond Lois of password may require 43 hours te recover View Only Account Name Old Password New Password New Password Again i again to confirm Warning Record your password Loss of pasword may require 48 hours te recover Seve Changes Admin Info Contact Name Contact Ernail sysContact Contact Phone Device Location sysLocation Device Description 00 19 85 E0 3D AC sysName Seve Changes Saved Configuration XML File na re Upload Local XML File Download Current XML File SSL Certificate and Private Key SSL Certificate and Private Key are INVALID SEL Certificate File SSL Private Key File Browse Upload SSL Files Erase SSL Doto Up
6. ai Rea i E nana sens tene einen lee nine tee dedans 35 Remote Sensors ea dassmsss sun aasenelnaeemees mac sos tene eine cantons steel d cerne annee 35 CONNECTING Remote Sensors iii 36 Data Logging and a B EE 36 REMOTE OUTLET SWITCHING 2 een 37 Let e EE 37 CONU E 38 Power On ACIONS EE 38 ACCESSORIES ee eee ene eee ee 39 PROLOG FoI AY ae nds ee denis has tete date Dire 39 IP Addressable Network Camera 39 Alternate Data kommate ann nenn ann nnn nme n ann nun nnnnnnnn ann nn nennen nenn 39 SERVICE AND TECHNICAL SUPPORT 22 224 240 200 0000000nann ann ann nnnn ann mann ann annnnnnnannnnnennen 40 Fiimware e EE 40 Firmware Bee EE 40 ESEL ICH OU EE 40 Ce a seen Se nee tee E te Die ete Res ee te dt ete 40 COLOS e ee EE 40 4 Version 1 0 PViQ Switched POU Specifications Overview The PViQ switched units have outlet control and circuit monitoring Web pages including graphs are generated by the unit to monitor power and environmental conditions within the cabinet No software other than a web browser is required for operation and several data formats are available In the PViQ Switched series built in sensors monitor Voltage Current instantaneous and cumulative Power as well as calculated Power Factor The PViQ Switched per Outlet series includes all standard PViQ Switched sensors plus additional current sensors to monitor individual outlet current Optional external sensors and network cameras are a
7. can be set to send multiple notifications for an alarm that remains in a tripped state The alarm notifications are set to repeat at intervals of no repeat 10 30 or 60 minutes by selecting the desired option in the drop down menu on the Alarms page V Note Changes in settings take a few moments to become active Rapidly resetting alarm values may not provide the desired results Allow up to 2 minutes after changing a setting before modifying it again 34 Version 1 0 PViQ Switched POU Sensors Overview All internal sensors are measured every 15 seconds External sensors are measured every 15 to 30 seconds depending on the number of devices connected Sensor data collected by the unit gives useful trend analysis data While all values are not absolute in relation to a known unit trend analysis of the data allows users to view changes and draw useful conclusions about what is happening over time in the monitored environment Internal Sensors The POU contains the following onboard sensors e Kilowatt Hours Cumulative sum of Real Power e Volts Measures instantaneous RMS voltage e Volts Peak Reports the highest reported voltage since the last time the data was updated typically every 15 seconds e Amps Measures instantaneous RMS current e Amps Peak Reports the highest reported current since the last time the data on the screen was updated typically every 15 seconds e Real Power Average of instantaneous voltage and
8. current over the last 1 5 seconds e Apparent Power The product of instantaneous RMS Voltage and RMS Current This is the value used by circuit breakers e Power Factor The ratio of Real Power to Apparent Power The PViQ Switched with Outlet Monitoring POUs contain the following additional onboard sensors Group Volts Measures instantaneous RMS voltage for a group of outlets Group Amps Measures instantaneous RMS current for a group of outlets Outlet Amps Measures instantaneous RMS current for each outlet Outlet Volts Measures instantaneous RMS voltage for each outlet Outlet Amps Measures instantaneous RMS current for each outlet Outlet Real Power Average of instantaneous voltage and current over last 1 5 seconds for each outlet e Outlet Kilowatt Hours Cumulative sum of Real Power for each outlet Remote Sensors Available Sensors e PVQ EST 12 Environmental sensor Temperature e PVQ ESTAFHD 12 Environmental sensor Temperature Air Flow Humidity Dew Point Please contact Panduit Technical Support if you need assistance locating your current version or upgrading to the new firmware version Version 1 0 35 PViQ Switched POU Connecting Remote Sensors Plug and play remote sensors may be attached to the unit at any time via the RJ 12 connectors on the face of the unit In some cases splitters may be required to add additional sensors Each sensor has a unique serial number and is automatically discovered and add
9. Arms 0 10 Arms 2 00 Watts 11 9 Watts 16 9 16 9 118 50 Vims 118 80 Vrms 0 10 Arms 0 10 Arms 2 00 Watts 11 9 Watts 16 9 121 50 Vims 121 60 Vrms 0 10 Arms 0 10 Arms 3 00 Watts 12 2 Watts 24 7 0 00 Arms 0 00 Arms 0 00 Arms 214 20 Vrms 219 50 Vrms 217 10 Vems 74 07 F 73 85 F 3d id Od Maximum loggable time span 5 89 days rm DOOO O0 DD 0000000 0000 R RU r 0000003 LCD LCD O C Reset Logs Save Changes Q LRU Re Re Re E E E E OO 00 E E E E E E E Q noooogs Click here to download CSY log data O1EE233B140000B9 Logging Control Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal SIE3 EI SSS SH Sy SHS SS SS S SS HS Normal 3111233814000089 Logging Control High water Mark Normal Nj Normal vj Normal v Normal k Normal v ECOO000246BEDC28 Logging Control Normal M DC0000024696AE28 Logging Control Normal v PViQ Switched POU Display Page The Display page allows the user to assign friendly names to attached sensors as well as change the default temperature unit of measure for external sensors The displa
10. GUNG Tu 7 MOUNTING ee dead na die 8 E Cie 8 Toolless Mounting Hardware sers 9 NETWORK TT 11 Network OvervieW snannnnnannnnennrnnnnrnsenrrrnnrrrsnnrrrsnrrrnnironnnrrnnnrrrnnrrennnrrrnnrrrnnnrnrenrrrnnneronnnenne 11 Default IP Address is iieesseerreeeessereennnnss 11 TE ESS ee ee ee ee ee 11 WEB INTERFACE nee aaa ee 13 KEE 13 D S OS PAGE ae a eo ee el 13 EOGGING A Age PE nee A E E E E E 15 Mia Ae E 16 PEAU RAR CSA EE 17 CONVO P ARS re rt toner 18 COMMO ACTIONS TaD ne nenna anaita ernennen aeaa EEEa 18 Control SOTINGS TAD EE 19 Configuration et EE 20 Configuration Network Tab iii 20 Configuration Monitoring Tab ss 21 Configuration Diagnostics Tab se 22 Configuration Event Log Tab 23 Configuration Admin Tab EE 24 UNIT CONFIGURATION 2 en coma nnnm 25 Network Configuration ccccccssccccccssseeccecceeeecceceeeuseceeesseuseceeeaueseeeesseaaeeeeessaaaeeeeessaaeeeesessagess 25 DINE and D AIR de an ne nn E ee it een me a nn 26 SUE Ed ee 26 AUIS ee E 28 TO 28 Accounts and Hassworde sisi 29 ARS ILES EP E 30 Camera CGonfouraton 30 OA MO AIO ee es 30 PMO Wa POUSSE en ana da en ea aie ee ns 31 ANE FIS ACID ds caen a ta a A mo do ince 31 SSL Certificate Upload ii iiiiiiessseerrreeeeeeesseeens 32 Version 1 0 3 PViQ Switched POU DANS na de a 33 Alarm Notifications roue dtn ea aan ea aan han nage tenter RE nenne een 33 PUMA Ee 33 BR 1 CES 016 0 EE 33 SENSOR gege EEN 35 EEN 35 Internal Sensors sea dus
11. NDUIT PViQ POU 1 Switched PViQ POU 1 Switched v3 5 6 IP Address 192 168 1 110 i 2 Local Time Wed 12 15 10 11 12 19 Allis well 3 Alarms monitored Control Sensors PYiQ POU 1 Switched Configuration Alarms Logging Outlet Name Hal GE Reboot Display 1 Outlet 1 0 0 Config 2 Outlet2 0 0 Control 3 Outlet 0 0 0 Actions 4 Outlet 4 0 0 0 Settings 5 Outlet5 0 0 0 Help 6 Outlet6 0 0 0 7 Outlet 0 0 0 ee 8 Outlet8 0 0 0 9 Outlet 0 0 0 10 Outlet 10 0 0 0 11 Outlet 11 0 0 0 12 Outlet 12 0 0 0 13 Outlet 13 0 0 0 14 Outlet 14 0 0 0 15 Outlet 15 0 0 0 16 Outlet 16 0 0 0 Save Changes 17 Outlet17 0 0 0 18 Outlet 18 0 0 0 19 Outlet 19 0 0 0 20 Outlet 20 0 0 0 21 Outlet 21 0 0 0 22 Outlet 22 0 0 0 23 Outlet 23 0 0 0 24 Outlet 24 0 0 0 Max Group Amps 29 Range 0 to 20 amps PViQ POU 1 Switched Power On Actions Outiet Due a On on last 1 Outlet 1 0 2 Outlet 2 0 O 3 Outlet 3 0 CH CH 4 Outlet 4 0 CH 5 Outlet 5 0 CH CH 6 Outlet 6 0 CH CH 7 Outlet 7 0 CH 8 Outlet 8 0 CH CH 9 Outlet 9 0 CH CH 10 Outlet 10 0 CH CH 11 Outlet 11 0 CH CH 12 Outlet 12 0 O O 13 Ou
12. NS Servers Allows the unit to resolve host names for Email NTP and SNMP servers as well as cameras Version 1 0 25 PViQ Switched POU Time and Date The system clock is set on the Admin tab of the Configuration page The unit comes preconfigured with the IP addresses of two NIST time servers and is set to the Central Time Zone 0500 GMT Should a local time server be preferred enter its IP address into the NTP primary server box and click the Save Changes button Clearing the time server addresses and clicking Save Changes will set the time servers back to the defaults The unit attempts to contact the time servers during boot up and periodically while running Until a time server is contacted or the system clock is manually set all log time stamps will present time as the number of seconds since the unit was powered up and graphs will not be shown System Clock set to GMIT Set Clock method Manual GMT ze GMT to local hh mm 95 00 Month Da Year Hour Minute Second yy 0 23 0 59 0 59 NTP primary server 192 43 244 18 192 43 244 18 NTP secondary server 129 61528 129 56 15 28 Sync to NTF server period 1800 seconds save Changes The time date IP address and friendly name of the unit are displayed in the top of each web page PYiQ POU 1 Switched IF Address 192 166 1 110 Local Time Wed 12 15 10 11 37 48 v The time and date are not adjusted for daylight savings time Settin
13. O O d O d O O d setvars dynweb A O Fi O Pi O O O snmp Fi O Fi i Pi Fi O Fi alarms Fi F F Fi O O P d email Fi O O O d O P Fi rtclock O O O O d O i Fi sntp Fi oO Fi Fi Pi O O O dns Fi F F O O O F Fi datalog d O Fi i d O O Fi graphin Fi O d oO oO O oO Fi firmwar O Fi Fi Fi d O O Fi msgcatlg Fi F Fi O Fi O O Fi E mail gni testdomain local C Send logs now Save Changes Version 1 0 23 PViQ Switched POU Configuration Admin Tab The user can set the system clock and administrative information on this tab Additionally the user can set administrator and account passwords See Unit Configuration section for details PANDUIT Pv POU 1 Switched PViQ POU 1 Switched v3 5 6 IP Address 192 168 1 110 m Local Time Wed 12 15 10 11 32 19 All is well 3 Alarms monitored Configuration Sensors Aler na All Parameters Logging Reset ALL to Detauh Values Display Config Ret DNS Cache Network Monitoring Diagnostics PVIQ POU 1 Switched Reset kWh Event Log Reset Circuit A Admin Control Pisset 8 Help PDA Pt j XML MIB Reset Circuit C Reset all circuits System Clock set to GMT Set Clock method Manual GMT GMT to local hh mm 05 00 Month Day Year Hour Minute Second 12 15 10 16 32 19 ry 0 23 0 59 0 59 NTP primary server 792 4324418 192 43 244 18 NTP secondary server 1296 15 28 129 6 15 28 Sync to NTP server period 1800 seconds Save Changes Daylight Saving Time DST is DISABLED
14. Unified Physical Infrastructure 6000 Panduit PViQ Switched POU User Manual Switched and Environmental Monitored Switched with Per Outlet Power and IT 2 0 PViQ Switched POU Copyright 2010 PANDUIT Corp All rights reserved No part of this book shall be reproduced stored in a retrieval system or transmitted by any means electronic mechanical photocopying recording or otherwise without written permission from PANDUIT No patent liability is assumed with respect to the use of the information contained herein Although every precaution has been taken in the preparation of this book PANDUIT assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein 2 Version 1 0 PViQ Switched POU Contents SPECIFICATIONS 2 en ae ae 5 VEC a as een Sea ea en NR E ee en 5 Environment 5 Temperature cccccccesecccceeseeecsesececseseccseusceessaeeecsauseceseuseeessaeeeeseuseeessaseeessageeeesaseeesssaeeeenes 5 RE LR AIT LE EE 5 EIEVAUON E 5 EI EC II A ee ee en En ee 5 Receptacle THANG GE 5 NEIWOLK Ile Se Gee es doce matted a Sn maar Pel mean ne da ea te 6 PROS ane eee eee ree en de ee eee eee eee 6 Ethernet Link Speed cccecccccccsseeceeccaeseececcceeeeeeeseaeaeeceeseeaaeeeeeesaaaseeeesseaaeeeeessaageeeeessaaaes 6 Dala Formals ee ee ee 6 EINIG VEITICA OF en de E a 6 INSTALLATION na se ee ausruhen ei 7
15. apshot opens the camera s website in a new browser window Camera model and IP address are entered on the Monitoring tab of the Configuration page v Note Some cameras require additional software downloads to display live video in a web browser Alternate Data Formats In addition to the full access control and configuration available via a desktop web browser PViQ Networked and Environmental POUs products present data in multiple formats for easy integration with other monitoring systems Data formats available via links on the unit s web page are PDA Phone All MIE e PDA Phone Presents data in a format best suited for PDA or cellular phone web browsers e XML Extensible Markup Language Presents data in a structured tree for use with automated scripts and monitoring systems e MIB Management Information Base Downloads the MIB for use with SNMP monitoring tools Version 1 0 39 PViQ Switched POU Service and Technical Support Firmware Version The firmware version is located in the upper right section of the web interface header represented by V3 Y XX PYiQ POU 1 Switched PYiQ POU 1 Switched v3 5 6 IP Address 192 168 1 110 Local Time Wed 12 15 10 11 51 50 Allis well 3 Alarms monitored Before contacting support Panduit recommends the POU first be updated to the latest firmware version If this is not possible please have the existing firmware version number for the unit available when contacting technical
16. ars from pairs path dyn config monitoring Control eaa leyenda Mapa setvars vars_from pairs got vars_config lock O field 12 15 2010 16 16 14 setvars vars reset dhcp status resetting net dhcp sta Help 12 15 2010 16 16 14 setvars vars from pairs path dyn config htm 12 15 2010 16 16 14 setvars vars from pairs got vars config lock O field PDA Phone 12 15 2010 16 12 18 setvars vars from pairs path dyn control config htm XML MIB 12 15 2010 26 12 19 setvars vars from pairs got vars config lock O field 12 15 2010 16 09 45 setvars vars from pairs path dyn_control htm 12 15 2010 16 09 45 setvars vars from pairs got vars config lock O field 12 15 2010 16 06 36 setvars vars from pairs path dyn alarms htm 12 15 2010 16 06 36 setvars vars from pairs got vars config lock O field 12 15 2010 16 05 30 setvars vars from pairs path dyn display htm 12715 2010 16 05330 setvars vars from pairs got vars config lock 0 field 12 15 2010 16 00 03 setvars vars from pairs path dyn logging htm au Aer setvars vars from pairs got vars config lock O field 12 15 2010 0 45 47 setvars vars wrt_task Wrote saveblock to flash wi L il gt Memory Syslog Subsystems Severity emergency alert critical error warning notice inform debug os Fi a Fi O O O adl O Iwip d F d O d O O Fi socket Fi O Fi d d O O O macphy Fi O d oO O O O d flashfl Fi O d O O d O O websery d d Fi O d O O Fi spiOdev d O d O O O d Fi device d O d O d O O 0O host
17. ay Used in conjunction with On and Last actions to allow sequencing of outlet power up to prevent overloading circuit breakers with inrush current e Off Leaves the outlet off until turned on manually via the Control Actions page e On Turns the outlet on e Last Returns the outlet to its state prior to the unit losing power Outlets with their delay values set to 0 will perform the selected action immediately upon receiving power Units with built in circuit breakers Should one of the unit s circuit breakers trip upon being reset any outlets powered by that breaker will perform their power on actions 38 Version 1 0 PViQ Switched POU Accessories Remote Display This small module can be mounted in an accessible spot inside or outside the rack or cabinet backlit LCD display scrolls the values of items selected on the Logging page The display is connected to the main unit via a 4 conductor handset style cord The display s onboard buzzer can be used in conjunction with E Mail and SNMP to provide local alarming of error conditions The buzzer can be silenced via the button on the face of the module however the display s LED indicator will remain lit until the alarm condition is cleared IP Addressable Network Cameras The unit is able to interface with up to four IP addressable network cameras A live snapshot from each camera will be displayed on the units Sensors page underneath the main unit s graph Clicking on a Sn
18. ayed actions are subject to the delays set on the Settings Tab of the Control page Version 1 0 37 PViQ Switched POU Configuration The PViQ Switched POUs are equipped with individually switchable outlets The unit lists all available outlets under Configuration on the Settings tab of the Control page Each outlet has five fields associated with it PYIiQ POU 1 Switched Configuration Delay seconds Power On Power Off Reboot ome fp fe le e Name A friendly name to easily identify what is plugged into the outlet For example Mail Server e URL A URL associated with the equipment plugged into the outlet This will appear as a clickable link on the Control Actions Tab next to the outlet status information e Power On Delay Delay from the time the On Delayed action is executed until the outlet will turn on e Power Off Delay Delay from the time the Off Delayed action is executed until the outlet will turn off e Reboot Delay Delay from the time the Reboot action is executed and all selected outlets have turned off until the outlet will turn back on Outlet Name URL v Note All delays are in seconds Power On Actions The state of each of the unit s switched outlets on power up is user configurable by setting a power on action DN POU 1 Switched Power On Actions Delay Action Outlet Name seconds On Off last 1 Outlet 1 1 Gi Available settings are e Del
19. ed to the web page Up to sixteen sensors may be connected The display order of the sensors on the web page is determined by the serial number of each sensor Friendly names for each sensor can be customized on the Display page v Note The sensor uses Cat 3 wire and RJ12 connectors Wiring must be straight through reverse polarity will temporarily disable all sensors until corrected v Note The sensors use a serial communication protocol and are subject to network signaling constraints dependent on shielding environmental noise and length of wire Typical installations allow runs of up to 600 feet of sensor wire Data Logging and Display All data collected by the unit can be graphed except kilowatt hours and outlet level data The Logging page allows the user to select data to be logged The user can also choose to view a graph of any logged data Selected sensor values are logged into the data file at a rate of one point per minute Logged values selected for graphing will be displayed on the optional Remote Display The number of selected sensors determines the maximum data logging time span This period is calculated and displayed on the Logging page The oldest data will be deleted when the onboard memory fills up in order to make room for new data 36 Version 1 0 PViQ Switched POU Remote Outlet Switching Actions There are seven possible actions for any given outlet available from the Action drop down box on the
20. email can be sent from the bottom of the Monitoring tab of the Configuration page v The unit cannot receive e mails The POP3 server is used strictly for authentication and is not required when using None or ESMTP Version 1 0 27 PViQ Switched POU Status Reports When enabled the unit will periodically send a full status report to all To e mail addresses selected for the report The report includes current unit data from all attached sensors as well as alarm states Reporting frequency options are weekly hourly every 2 3 4 6 8 12 24 or 48 hours E mail addresses are selected when the report is created by checking the corresponding e mail destination box Allowing the cursor to hover over an e mail destination box will display the e mail address that the box is associated with System Status E Mail Reports hour min Report Time Report Period 24 hours w 0 235 0 59 E mail Destinations O O O O O Delete This Report L save Changes Add New Report SNMP The unit supports retrieval of all data via Simple Network Management Protocol SNMP v1 v2c and v3 In addition alarm traps can be sent to up to two IP addresses The SNMP configuration is entered on the Monitoring tab of the Configuration page SNIP SNMP Service Enabled ae Read Community public Listen port for GET Trap Community Write community Trap Type v2C Notify ze oa fo fs oo CH E SE Trap IF Addres
21. ered by the POU is recommended to avoid high inrush current Caution Disconnect all power cords before servicing Version 1 0 7 PViQ Switched POU Mounting L Bracket Affix Power Strip Mounting mounting brackets using 12 24 screws provided into tapped holes in the front or the sides of the post Power Strip Mounting Brackets can also be mounted to the rear equipment rails To center the 66 25 vertical power strips e For 7 foot post racks mount L Bracket at RU spaces 03 and 43 e For 8 foot 4 post racks mount L Bracket at RU spaces 06 and 46 or spaces 07 and 47 e For 6 5 foot 4 post racks flip bottom bracket 180 and mount L bracket at RU spaces 02 and 40 Mount power strip between brackets secure brackets using 12 24 Screws tr M li Power Strip i pu Side of post installation Front of post installation Flip bottom bracket 180 for 6 5ft rack 8 Version 1 0 PViQ Switched POU Toolless Mounting Hardware Use toolless buttons with key holed slots built into cabinet or with optional key holed brackets DETAIL A __ Power Outlet Unit POU Button of POU installed CI LL CES re re LI EL CIEL EL CR KSM Version 1 0 9 PViQ Switched POU CO 0 O Ou 2 O T Le c amp D Version 1 0 10 PViQ Switched POU Network Setup Network Overview This product comes preconfigured w
22. g the time zone offset forward and backward an hour will cause a gap or overwriting of logs respectively E Mail The unit is capable of sending e mail to as many as five addresses at once Most SMTP and ESMTP servers are compatible Authentication options are None POP3 POP before SMTP or ESMTP The unit can be configured to send alarm emails always only during business hours or only after hours by selecting the desired option next to each email address The e mail configuration and normal business hours are set on the Monitoring tab of the Configuration page 26 Version 1 0 PViQ Switched POU E mail SMTP Server 192 168 01 192 168 0 1 SMTP Port Business After Send alarms to this recipient Always Hours Hours SMS To E mail Address 1 O To E mail Address 2 Po To E mail Address 3 Po To E mail Address 4 Po To E mail Address 5 Po io o o 2 POPS Fort 110 Password Ys oo 3 S Soo 3 amp ssa Business Hours Start Time End Time Sun Mon Tue Wed Thu Fri Sat Week Days 2 d save Changes An SMTP server as well as From and To addresses are required to send e mails Some mail servers may require a username and password In most cases the username does not have to match the From address but does need to be a valid user on the authenticating server Microsoft Exchange servers will have to be set to allow SMTP relay from the IP address of the unit In addition a test
23. he optional remote display module Checked readings in the Logged Measurements section are logged into the data file at a rate of one point per minute and will be available for graphing and display Note that although data is logged once per minute all sensor data used in the real time display and alarm functions is read at least once every 15 seconds for internal sensors and once every 30 seconds for external sensors Recorded data is available for download in a comma separated values CSV file PANDUIT Sensors Alarms Logging Display Config Control Help PDA Phone XML MIB Version 1 0 PYiQ POU 1 Switched IP Address 192 168 1 110 Local Time Wed 12 15 10 11 00 03 140 Logging Sensor Measurement Data Graph PYiQ POU 1 Switched v3 5 6 Allis well 3 Alarms monitored 100 80 60 40 20 0 Sd 4d Time Range 1 Month M PYiQ POU 1 Switched on m Volts Peak 4 Amps 4 Amps Peak 4 Real Power 4 Apparent Power 4 Power Factor 4 Power Factor 4 Volts B Volts Peak B Amps B Amps Peak B Real Power B Apparent Power B Power Factor B Volts C Volts Peak C Amps C Amps Peak C Real Power C Apparent Power C Power Factor C Power Strip B amps croup a Amps Group B Amps Group C Volts Group A Volts Group B Volts Group C Temp Sensor Temperature F Temp Sensor Temperature F 118 70 Vims 118 90 Vrms 0 10
24. itched Control Logging Group A 213 80 0 00 Arms Display Outlet Name Status A kwh Watts URL O 1 Outlet 1 On 0 00 1 399 0 Config O 2 Outlet 2 On 0 00 0 020 0 Control CT 3 Outet3 On 0 00 0 010 0 Actions F 4 Outlet 4 On 0 00 0 003 0 Settings O 5 Outlet 5 On 0 00 17 763 0 Help O 6 Outlet 6 On 0 00 0 011 0 O 7 Outlet7 On 0 00 0 003 0 PDA Phone d 8 Outlets On 0 00 0 005 0 XML MIB Group B 218 95 V 0 00 Arms C Outlet Name Status Arms kwh Watts URL O 9 Outlet 9 On 0 00 13 392 0 O 10 Outlet 10 On 0 00 0 016 0 d 11 Outletil On 0 00 0 003 0 O 12 Outleti2 On 0 00 0 008 0 O 13 Outlet13 On 0 00 0 017 0 d 14 Outlet14 On 0 00 0 003 0 O 15 Outlet15 On 0 00 0 008 0 DO 16 Outleti6 On 0 00 0 004 0 Group C 216 80 0 00 Arms m Outlet Name Status Arms kWh Watts URL d 17 Outlet17 On 0 00 0 009 0 F 18 Outlet18 On 0 00 0 003 0 O 19 Outlet19 On 0 00 0 011 0 O 20 Outlet20 On 0 00 0 008 0 O 21 Outlet21 On 0 00 0 003 0 F 22 Outet22 On 0 00 0 012 0 F 23 Outlet 29 On 0 00 0 008 0 oO 24 Outlet24 On 0 00 0 001 0 Action None v Execute 18 Version 1 0 PViQ Switched POU Control Settings Tab The Settings tab on the Control page allows the user to name and define a URL for outlets in addition to setting time delays for each outlet action Boot up status and sequential boot up options are also available All delay settings are referenced from the trigger event This tab also allows the user to restore factory default settings PA
25. ith a default IP address set Simply connect to the POU and access the web page with your browser Default IP Address The PViQ Switched units have a default IP address for initial setup and access to the unit if the assigned address is lost or forgotten Once an IP address is assigned to a unit the default IP address is no longer active To restore the default IP address press and hold the reset button located below the network connector for 20 seconds The idle and activity lights on the network connector will both light up when the IP address has been reset The reset button is accessed through the white circular hole located below the Ethernet jack Note Pressing the reset button under the network connector will restore the default IP address and will also clear all password settings The Configuration page allows you to assign the network properties or use DHCP to connect to your network Access to the unit requires the IP address to be known so use of a Static IP or reserved DHCP is recommended The default address is shown on the front of the unit IP Address 192 168 123 123 Subnet Mask 255 255 255 0 Gateway 192 168 123 1 Initial Setup 1 Connect POU to your computer using a crossover cable On your computer go to Start gt Settings gt Control Panel gt Network and Dial Up Connections 3 Right Click on Local Area Connection and select Properties 4 Select the option to Use the following IP address
26. larms PYiQ POU 1 Switched ID 01EE233B140000B9 Logging kwatt hours 4 13 79 kwh Display Modo 118 40 Vrms Config ct Peak 4 118 70 Vrms Control amps A 0 10 Arms Help amps Peak 4 0 10 Arms PDA Phone rea Power 4 2 00 Watts KML MIB B apparent Power 4 11 8 Watts rower Factor 4 16 9 Ga kWeatt hours B 10 57 kWh volts e 118 60 Yims vots Peak B 118 80 Vims amps B 0 10 Arms amps Peak B 0 10 Arms rea power B 2 00 Watts Aert Power B 11 9 Watts rower Factor B 16 9 kWatt hours C 5 63 kWh on 121 20 Vrms Boit Peak c 121 50 Vrms BB C 0 10 Arms amps Peak C 0 10 Arms rea Power C 3 00 Watts B apparent Power C 12 1 Watts Brower Factor C 24 8 140 100 DU 60 40 Eege So 0 SO Sd 4d 3d 2d Id Od Version 1 0 13 PViQ Switched POU Power Strip ID 3111233814000089 DM Group A 0 00 Arms Br Group B 0 00 Arms James Group 0 00 Arms vcs Group 4 213 95 Yims vats croup E 219 25 Vems vats Group 217 25 Vrms 250 200 150 100 50 0 Sd 4d ad ad ld Od Temp Sensor ID ECOOO00246BEDC2S temperature IF 74 53 F 79 TO TT 6 75 a Sd 4d Id zd id Od 14 Version 1 0 PViQ Switched POU Logging Page The Logging page allows the user to access the historical data by selecting the desired sensors and time range to be logged Checked readings in the Sensor Measurement Data Graph section are graphed on the Logging page and displayed on t
27. load System Firmware Firmware package file Browse Upload New Firmware Firmware upload may take a few minutes Please wait for response from browser 24 Version 1 0 PViQ Switched POU Unit Configuration Network Configuration The unit s network configuration is set on the Network tab of the Configuration page Settings pertaining to the unit s network connection are Network Current Network Configuration set statically Use DHCP f r Network Configuration and DNS Server Addresses Use DHCP f r Network Configuration and Static DNS server addresses Use Static Network Configuration and DNS server addresses IP Address 192 166 1110 Subnet Mask 255 255 252 0 Gateway 192 168 0 2 Primary DNS Server agog Secondary DNS Server 9 9 4 4 save Changes Web Server Protocols HTTF and HTTPS ze HTTF Fort HTTPS Fort 1443 Telnet Service Enabled save Changes e DHCP Allows the unit to request a dynamic IP address from a server on the network Static IP Address Net Mask Gateway When not using a dynamic address enter static network configuration information here e Telnet Service Enable or disable the built in Telnet server e HTTP Services Enables disables access via HTTP and HTTPS Available options are HTTP and HTTPS HTTP only and HTTPS only It is not possible to disable the web interface completely e HTTP HTTPS Server Port Changes the TCP port that each server listens on D
28. lso available Environmental Temperature Operating 10 C 50 F min 45 C 113 F max Storage 25 C 13 F min 65 C 149 F max Humidity Operating 5 min 95 max non condensing Storage 5 min 95 max non condensing Elevation Operating 0 m 0 ft min 2000 m 6561 ft max Storage O m 0 ft min 15240 m 50000 ft max Electrical See nameplate for unit ratings Receptacle Ratings NEMA 5 15R or L5 15R NEMA 5 20R or L5 20R NEMA 6 20R or L6 20R IEC 320 C13 IEC 320 C19 125 Volts 15 Amp 125 Volts 20 Amp 250 Volts 20 Amp 125 250 Volt 15 Amp North America or 10 Amp Global 125 250 Volt 20 Amp North America or 16 Amp Global Given ratings are per receptacle bank Version 1 0 PViQ Switched POU Networking Protocols HTTP HTTPS SSL TLS SMTP POP3 ICMP DHCP TCP IP NTP Telnet Syslog Ethernet Link Speed 10 100 Mbit full duplex Data Formats HTML SNMP CSV Plain Text XML EMC Verification This Class A device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada Warning Changes or modifications to this unit not expressly ap
29. nd Private Key SSL Certificate and Private Key are INVALID SSL Certificate File Browse J SSL Private KeyFile E Upload SSL Files Erase SSL Data 32 Version 1 0 PViQ Switched POU Alarms Alarm Notifications The PViQ Switched POUs support three types of alarm notification e E Mail The unit can be configured to send alarm e mails to up to five recipients e SNMP The unit can be configured to send SNMP traps to up to two trap servers e Buzzer When a remote display is attached the unit can turn on an audible alarm DM POU 1 Switched ID 01EE 233814000089 kvWat hours A Alarm must remain tripped for E mail ar Omin ze before notification gniStestdomain local P E mail 2 threshold Repeat every E mail 3 save Changes Add New Alarm The unit is capable of any combination of the above alarms at once Alarm type combinations are selected per alarm via the check boxes which are displayed for each alarm on the Alarms page Alarm Types The PViQ Switched POUS provide three types of alarm messages via E Mail and SNMP e Trip Occurs when a sensor value goes above a high trip threshold or below a low trip threshold e Clear Occurs when a sensor already in the Tripped or Unplugged state goes back into its normal range e Unplugged Occurs when a sensor with an alarm set loses contact with the main unit due to the sensor being physically unplugged or another communications error Alarms can be added fo
30. proved by the party responsible for compliance could void the user s authority to operate this equipment 6 Version 1 0 PViQ Switched POU Installation Guidelines e Ifthe POU is installed in a cabinet the ambient temperature should be no greater than 40 C e Install the POU such that the amount of airflow required for safe operation of equipment is not compromised e Mount the POU so that a hazardous condition is not achieved due to uneven mechanical loading e Follow nameplate ratings when connecting equipment to the branch circuit Take into consideration the effect that overloading of the circuits might have on over current protection and supply wiring e The POU relies on the building installation for protection from over current conditions A Listed circuit breaker is required within the building installation The circuit breaker should be sized according to the POU s nameplate ratings and local national electrical codes e Reliable earthing of rack mount equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit The POU must be connected to an earthed socket outlet e The POU is intended for Restricted Access Locations only and only service personnel should install and access the POU e For pluggable equipment install the POU so that the input plug or appliance coupler may be disconnected for service e Sequential power up of devices pow
31. r each internal device or external sensor displayed on the Alarms page An alarm is added by pressing the Add New Alarm Button and selecting the sensor value to be monitored from a drop down menu Thresholds The user must set a trip threshold and type for each alarm that is added to the Alarms page The threshold type is chosen as either Below or Above from a drop down menu when the alarm is created The threshold value is typed into a data window when the alarm is created Alarms are triggered based on the selected sensor s data and the trip threshold type and value Alarm settings can be edited or deleted at any time Analysis of each unit is recommended before setting alarm thresholds as some of the values monitored by the unit are relative values whose scale will differ slightly between units Allow each unit to operate under normal steady state conditions for several hours before setting alarm thresholds By allowing the Version 1 0 33 PViQ Switched POU sensors to operate for several hours the user can better understand what the normal variations are thereby allowing the user to choose alarm thresholds that will not trigger numerous false alarms Alarms can be set to only send notification if the alarm is in a tripped state for a certain amount of time The user sets the amount of time required by choosing a value 0 1 5 or 10 min from the drop down menu on the Alarms page Additionally alarm notifications
32. ri Sat Week Days O O Save Changes System Status E Mail Reports Add New Report SNMP SNMP Service Enabled Read Community public Listen port for GET 161 Trap Community private Write Community p rivate Trap Type 2C Notify v Trap IP Address port 1 192 168 0 78 162 192 168 0 78 Trap IP Address port 2 Save Changes Initial SNMPY3 data Unauthenticated User initial Authenticated Manager manager Manager Authentication 12345678 Password Manager Privacy Password 42345678 Trap User Trap Trap Authentication 12345678 Password Trap Privacy Password 12345678 Save Changes Reset User Access NVRAM will occur during the finish page Cameras Cam 1 IP Address 9 0 0 0 Model No camera Mi Cam 2 IP Address 9 0 0 0 Model No camera he Cam 3 IP Address 0 0 0 0 Model No camera M Cam 4 IP Address 0 0 0 0 Model No camera Mi Save Changes Test SNMP Trap and E Mail Send Test SNMP Trap Send Test E Mail Version 1 0 21 PViQ Switched POU Configuration Diagnostics Tab The user can update the Syslog settings on the Diagnostics tab of the Configuration page Pan D PYiQ POU 1 Switched PViQ POU 1 Switched v3 5 6 DUIT Peer 11 24 35 Allis well 3 Alarms monitored
33. rm options include a local Buzzer Email and SNMP Trap PANDUIT Sensors Alarms Logging Display Config Control Help PDA Phone XML MIB Version 1 0 PViQ POU 1 Switched IP Address 192 168 1 110 Local Time Wed 12 15 10 11 06 36 PViQ POU 1 Switched v3 5 6 Allis well 3 Alarms monitored Alarms PYiQ POU 1 Switched ID 01EE233B140000B9 x Alarm must remain tripped for E mail kKatt hours A v Omn SS e Ee 0 min v before notification gni testdomain local trips if E mail 2 ea eke Repeat every No Repeat E mail 3 Save Changes Add New Alarm Power Strip ID 3111233B140000B9 Add New Alarm Temp Sensor ID EC00000246BEDC28 Alarm must remain tripped for E mail 4 a Temperature F v Bes U min v before notification E mail 5 rips if A 3 threshold 900 Repeat every 10 min wl 192 168 0 78 162 Save Changes Add New Alarm Alarm Behavior Unplugged Alerts Enabled v Save Changes 17 PViQ Switched POU Control Page The Control page has two sub tabs Actions and Settings See Remote Outlet Switching for details Control Actions Tab The Actions tab on the Control page gives the user control of the outlets Outlets can be rebooted or turned on off with or without pre programmed delays Bary PYiQ POU 1 Switched PViQ POU 1 Switched v3 5 6 DU IT We EE lern All is well 3 Alarms monitored Control Sensors Alarms PYiQ POU 1 Sw
34. s of password may require 45 hours to recover Control Account Name fs Old Password fs New Password fs New Password Again fe again to confirm Warning Record your password Loss of password may require 45 hours to recover View Only Account Name fs Old Password fs New Password fs Mew Password Again fs again to confirm Warning Record your password Loss of password may require 45 hours to recover save Changes User account names may include alphanumeric characters spaces and underscores Passwords may include alphanumeric characters and underscores v Note The Administrator account must be active to enable the Control Access and View Only accounts v Note The Control Access account must be active to enable the View Only account v Note The account names root and admin are disabled for security reasons and cannot be re enabled Warning Record your passwords To reset lost passwords follow the instructions for resetting the unit s IP address and passwords given in the Error Reference source not found ection To generate a temporary recovery password to access the unit contact customer service from a location where the unit can be accessed via the internet Version 1 0 29 PViQ Switched POU Telnet The unit provides a Telnet server for basic monitoring via the command line The Administrator account must be enabled to use the Telnet interface Type help after logging in to the unit
35. s port 1 119 166 0 7816 192 168 0 78 UE o oo m save Changes Initial SNMIPY3 data Lnauthenticated User Authenticated Manager Manager Authentication 17345678 Password Manager Privacy Password 12345678 Trap Lesr Trap Authentication 12345678 Password Trap Privacy Password 12345678 save Changes Reset User Access NYRAM will occur during the finish page 28 Version 1 0 PViQ Switched POU The default community string is public and the MIB is downloadable via a link at the top of the unit s web page Accounts and Passwords The POU units offer account security options that are entered on the Admin tab of the Configuration page There are three levels of account security e Administrator Password protects the Display Alarms and Configuration pages e Control Access Password protects the Control Actions and Control Settings pages e View Only Password protects the Sensors PDA WAP and XML pages Name and Password Configuration MOTE 1 IF Account currently has a password leaving Old Password blank results in no changes bo that account MOTE 2 Administrator password may be used in the Old Password feld of any account MOTE 3 IF setting Mew Password to blank Account Hame must also be blank MOTE d IF Mew Password is not blank Account Name must not be blank Administrator Account Name fs Old Password fs New Password fs New Password Again fs again to confirm Warning Record your password Los
36. support Firmware Updates Keep your unit updated with the latest firmware releases or sign up for notifications Contact Panduit Technical Support for information on updating your firmware or visit the following website http www panduit com Support MNS TechSupport index htm Resetting POU Should the POU lose communication the processor may be manually rebooted without affecting power to the outlets Pressing the Reset button on the face of the unit will cause the processor to reboot The web interface will remain off line during boot up Service No service or maintenance is required Do not attempt to open the POU or you may void the warranty No serviceable parts inside Panduit recommends that power be removed from the unit before installing or removing any equipment Technical Support For Technical Support on the PViIQ POU please contact Panduit Technical Support using one of the following methods e 1 800 777 3300 toll free e cs panduit com e http www panduit com Support MNSTechSupport index htm 40 Version 1 0
37. tlet 13 0 O O 14 Outlet 14 0 O O 15 Outlet 15 0 O 16 Outlet 16 0 CH O Save Changes 17 Outlet 17 0 O 18 Outlet 18 0 O 19 Outlet 19 0 O 20 Outlet 20 0 O 21 Outlet 21 0 O O 22 Outlet 22 0 O O 23 Outlet 23 0 CH 24 Outlet 24 0 O Save Changes PViQ POU 1 Switched Restore Defaults Reset ALL to Default Values Version 1 0 19 PViQ Switched POU Configuration Page The Configuration page has five sub tabs Network Monitoring Diagnostics Event Log and Admin See Unit Configuration for details Configuration Network Tab The user can enter and update the network settings on the Network tab of the Configuration page See Unit Configuration section for details Dan e PViQ POU 1 Switched PViQ POU 1 Switched v3 5 6 DU IT IP Address 192 168 1 110 All is well 3 Alarms monitored Local Time Wed 12 15 10 11 16 15 Configuration Sensors Alarme Network Logging Current Network Configuration set statically Display EEE Use DHCP for Network Configuration and DNS Server Addresses Config Use DHCP for Network Configuration and Static DNS server addresses Network Use Static Network Configuration and DNS server addresses Monitoring Diagnostics Event Log IP Address 192 168 1 110 Admin Subnet Mask op 265 262 0 Control Gateway 192 168 0 2 Help Primary DNS Server 18988 PDA Phone XML MIB Secondary DNS Server 8
38. to see a list of available commands The Telnet service can be disabled under Web Server on the Network tab of the Configuration page v Note All data sent via Telnet is unencrypted Some settings can be changed and user names and network settings are available via Telnet In secure environments it is recommended that Telnet be disabled Camera Configuration Enter the domain names IP addresses and models of up to four IP addressable network cameras in the Cameras section of the Monitoring tab on the Configuration page The unit will present a linked Snapshot from each camera on the Sensors page Cameras Cam 1 IP Address Model No camera Cam 2 IP Address in 000 Model No camera Cam 3 IP Address in 000 Model Mo camera Cam 4 IP Address Model Mo camera save Changes Note Each camera must be set to allow anonymous access to enable this feature E Admin Information Information entered in the Admin Info section of the Admin tab of the Configuration page will show up at the bottom of the unit s web interface Admin Info Contact Name Contact Email sysContact Contact Phone Device Location sysLocation Device Description sysName _Save Changes 30 Version 1 0 PViQ Switched POU Kilowatt Hours Reset The PViQ Switched POU unit s kilowatt hours measurements are zeroed at the factory and can be reset at any time should it become necessar
39. y On the Settings tab of the Control page simply hit the button that corresponds to the desired circuit to be reset DN POU 1 Switched Reset kWh Reset Circuit A Reset Circuit B Reset Circuit C Reset all circuits XML File Backup The POU unit s configuration is stored in the XML file The XML file can be downloaded and stored in order to backup the POU unit s current configuration settings On the Admin tab of the Configuration page simply hit the Download Current XML File button to download the XML file A previously downloaded XML file can be uploaded to the POU unit in order to restore the unit s configuration to match the configuration contained in the XML file On the Admin tab of the Configuration page click the Upload Local XML file button to upload a local XML file v Note XML files are unit specific An XML file should only be uploaded to the unit that it was downloaded from Saved Configuration XML File Upload Local zl File Download Current XML File Version 1 0 31 PViQ Switched POU SSL Certificate Upload The POU will automatically generate a unique SSL Certificate and Private Key Alternatively a custom SSL Certificate and Private Key can be uploaded to the POU by pressing the Upload SSL Files button on the Admin tab of the Configuration page The SSL Certificate and Private Key can be cleared by clicking the Erase SSL Data button on the Admin tab of the Configuration page SSL Certificate a
40. y page also allows the user to select between the default and classic web page layouts The default interface displays a vertical menu bar to the left of the main window while the classic interface displays a horizontal menu bar Tan PViQ POU 1 Switched PViQ POU 1 Switched 3 5 6 DUIT IP Address 192 168 1 110 All is well 3 Alarms monitored Local Time Wed 12 15 10 11 05 30 Display Sensors Alarms General Logging Date Format USA MM DD YY v Display Temperature Unit Fahrenheit Config SS Interface Type Default ze Help Scroll on LCD Measurements PDA Phone _ Save Changes Changes XML MIB Devices Unique Address Device Type Friendly Name O1EE233B140000B9 ctrl3ChIEC PQ POU 1 Switched 3111233814000089 ctrlGrp mps Power Strip ECOOO00246BEDC28 tempSensor Temp Sensor DCO00002469684E28 tempSensor Temp Sensor CT Remove all unplugged devices Save Changes Unit Location Unit Description 00 19 85 E0 3D AC Admin or Call Support Manuals cs panduit com or Call 800 777 3300 Copyright 2003 2010 Panduit Corporation All Rights Reserved 16 Version 1 0 PViQ Switched POU Alarms Page The Alarms page allows the user to establish alarm conditions for each sensor reading Alarm conditions can be established with either high or low trip thresholds The alarms are displayed in different sections based on the device the alarm is associated with Ala