1. 6 Service and Maintenance Always unplug the power plug before service and maintenance 6 1 Centrifuge Service The brushless motor in the Prism R requires no routine maintenance Any required service should be performed by authorized qualified Prism R Refrigerated Microcentrifuge 13 personnel only Repairs performed by unauthorized personnel may void the warranty 6 2 Cleaning the Centrifuge Always keep the centrifuge housing rotor chamber rotor and rotor accessories clean All parts should be wiped down periodically with a soft cloth For more thorough cleaning use a neutral cleaning agent pH between 6 and 8 applied with a soft cloth Excessive amounts of liquid should be avoided Liquid should not come into contact with the motor After cleaning ensure that all parts are dried thoroughly by hand or in a warm air cabinet Maximum temperature 50 C 6 3 Cleaning the Rotor The rotor should be cleaned after each use When spinning samples containing phenol or phenol chloroform the rotor should be cleaned immediately after use 6 4 Disinfection Should a spill of infectious materials occur within the rotor or chamber the unit should be disinfected This should be performed by qualified personnel with proper protective equipment 6 5 Replacing the Rotor The Prism R comes complete with a standard 24 place rotor installed To remove the rotor remove the rotor securing screw from the motor shaft by turni
2. 14 6 3 Cleaning the Rotor ccccccceeeseeeeseeeeeeeeeeeeeseeeneeees 14 6 4 DISINFECION nnen eee et 14 6 5 Replacing the Rotor cccccccceccceesssceeeeeeeeeeeeseeeteeees 14 6 6 Replacing fuses ccceeecceeeeeeeeeeneeeeeeeeeteeeeenaeeees 15 7 Troubleshoot NO a eia eana aienea aeneae eeen etr E 15 Appendix A Technical Specifications ssssssesnnnnnnneennnnnnnnnnnna 17 Table of Content Appendix B Warranty ccccccccsseeesseeeeeeeeseeeeeeeeeeeeeeeeeeeeeeeenenes 18 1 Safety Precautions Before using the Prism R refrigerated microcentrifuge for the first time please read this entire operating manual carefully To guarantee problem free safe operation it is essential to observe the following points 1 1 Operation Safety Precautions A 1 10 11 12 13 When using infectious radioactive toxic and other solutions which may pose health risks please observe the appropriate safety precautions Do not use this machine in a potentially explosive environment or with potentially explosive chemicals Install the machine in location free of excessive dust Avoid placing the machine in direct sunlight Choose a flat stable surface capable of withstanding the weight of the machine Install the machine in the room temperature 15 30 C relative humidity 20 80 Don t block the air vents Make sure the power source conforms to the required power supply specifications
3. Prism a User Manual C2500 R C2500 R 230V CE ve Labnet Lit M00502 July 2012 v2 1 Safety Precautions ccccccccseeessseeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeneees 1 1 1 Operation Safety Precautions 1 2 General Description eecceeeeeseeeeseeeeeeeeeeeeeeeeeeeeeeeeeeees 3 2l Features rir terse ie tte settee les a 3 3 Getting Started cccccccccsceeesseeeeeeeeeeeeeeseneeeeeeeeeeeeeeseeeeeeenees 3 Bd Unpatking cerei ateen ians 3 3 2 Initial Operation cee ccc ceeeeeeeeeeeeeeeeeneeeeeeeeeeeeeenaeeees 4 3 3 Opening and Closing the Lid c ceeeeeeeeeeeeeeeees 5 3 4 Loading the Rotor r eee e e aes 5 3 5 Starting and Stopping a RUN c ceeeeeeeeeeeeeeeteeeees 6 3 6 Emergency Lid Release ccceeeeeeeeeeeeeeeeetteeees 7 4 OA a eee rere te ec 8 5 Operations sseni ae aaeth atita aiiai iana 10 5 1 Setting the Time TIME 0 eee ceeeeeeeeeeeeeeneeeeees 10 5 2 Setting the Speed RPM 10 5 3 Setting the Centrifugal Force RCF eseese 11 5 4 Setting the Temperature TEMP nsee 11 DD UOOOMAMG A E ee tea nese lee aces T 11 5 6 Quick Spin Operation ccccccceeccecscseeeeeeeeeeeeeeeeeeees 13 5 7 Changing the Settings During a Run s es 13 6 Service and Maintenance ccccccccseeesseeeeeeeeeeeeesseeeeees 13 6 1 Centrifuge Service ccceccceeeeeeeeetteeeeeeeeeeeeeeeeeeees 13 6 2 Cleaning the Centrifuge
4. change the time setting The 2 digits of TIME on the display will flash Turn the START STOP knob to increase or decrease the value Press button again to confirm the selection or press START STOP knob to store and run the selection The flashing of time value will stop and the time value will be stored automatically if no button is pressed after 6 seconds of the adjustment Operating time can be set as continuous by turning the START STOP knob clockwise or counter clockwise to make the 2 digits of TIME to display When the time is set as Continuous the centrifuge will continue to run without a stop Press EJ START STOP knob to end the continuous operation 5 2 Setting the Speed RPM The speed RPM can be selected from 500 to 13 500 rpm Press button to change the speed setting The 5 digits of speed RPM on 10 the display will flash Turn the START STOP knob to increase or decrease the value Press button again to confirm the selection or press EJ START STOP knob to store and run the selection The flashing of RPM value will stop and the RPM value will be stored automatically if no button is pressed after 6 seconds of the adjustment 5 3 Setting the Centrifugal Force RCF The speed can be selected from 20 to 17 200 x g too Press button to change the RCF setting The 5 digits of RCF on the display will flash Turn the EJ START STOP knob to increase or decrease the v
5. 5 g Acceleration Time lt 17 seconds Deceleration Time lt 18 seconds Temperature Range 10 C to 40 C Max Rotor Capacity 24 x 2 0 1 5ml tubes Rotor Lid Easy snap on type Time Range 0 5 to 99 min or continuous Admissible Sample Density 1 2Kg ml Noise at Max Speed 56 dB Operating Temperature 5 C to 30 C Operating Humidity RH 20 80 Prism R Refrigerated Microcentrifuge 17 100V 50 60 Hz 6 0A Power Supply 110V 50 60 Hz 5 5A 230V 50 60 Hz 2 8A Dimensions W x L x H 280 x 430 x 248 mm Weight with Rotor 22 Kgw Certification Complies with CE Class B EN60101 1 2 EN 55011 Complies RoHS Note 1 Specifications are subject to change without prior notice Appendix B Warranty Prism R refrigerated microcentrifuges are covered by a warranty for two years against defects in materials and workmanship This period begins from the date of purchase and within this period all defective parts will be replaced at no charge by Labnet International Inc The warranty does not cover defects caused by excessive wear and tear or damage due to shipping accident abuse misuse problems with electrical power or usage not in accordance with product instructions or if other than original spare parts supplied by the manufacturer have been used Each Prism R refrigerated microcentrifuge is tested and documented by the manufacturer
6. To avoid electric shock make sure the machine is plugged into a grounded electric outlet Do not allow water or any foreign objects to enter the various openings of the machine Switch off the power switch before cleaning or performing any service on the machine such as replacing the fuses The rotor and the rotor lid must always be installed securely on the motor shaft Always load the rotor symmetrically Each tube should be counterbalanced by another tube of the same type and weight Prism R Refrigerated Microcentrifuge 1 14 To guarantee sufficient ventilation ensure that the centrifuge has at least 30 cm of free space on all sides including the rear 15 Repair should be carried out by Labnet International authorized service personnel only 16 Use original spare parts and accessories only A Warning Label Please be aware of the danger of electric shock or other dangers 2 General Description The Prism R refrigerated microcentrifuges is a compact bench top centrifuge which is suitable for both research and clinical laboratories The motor is brushless and requires no routine maintenance It is supplied with a 24 x 1 5 2 0 ml rotor for micro samples The maximum speed of Prism R is 13 500 rpm 17 135 rcf The temperature range is from 10 C to 40 C 2 1 Features Brushless motor drive control speed up to 13 500rpm 17 135xg Powerful refrigeration system maintain 4 C at max speed Includes unique ea
7. ad Function Button Symbol Function Description START STOP e painted a run by pressing and Value ED pi 3 u e Rotate to Increase decrease the Adjustment ae ne enad i Knob values of time temperature spee or g force TIME button e To adjust run time setting RPM button e To adjust speed setting RCF button e To adjust RCF setting TEMP button rene e To adjust temperature setting LID button e Open the lid QUICK button D e Quick Spin centrifugation Audible Signals The audible signals are beneficial when you are familiarizing yourself with the operating procedure of the Prism R refrigerated microcentrifuge They can also be disabled if desired by pressing button six times The audible signal function can be resumed by pressing button six times again Definition of the audible sounds are shown in the table below Audible Sound Operation 2 beeps Power on machine 3 beeps End of a run Prism R Refrigerated Microcentrifuge 9 5 Operation Users can pre set the time temperature and speed RPM RCF before arun Attention Never attempt to operate the centrifuge with rotors or adapters that show signs of corrosion or mechanical damage Never centrifuge strongly corrosive materials that may damage the rotors accessories or bowl of the unit 5 1 Setting the Time TIME Operating time can be selected from 0 5 min to 99 min or continuous Press button to
8. alue Press button again to confirm the selection or press START STOP knob to store and run the selection The flashing of RCF value will stop and the RCF value will be stored automatically if no button is pressed after 6 seconds of the adjustment 5 4 Setting the Temperature TEMP The temperature can be selected from 10 to 40 C Press button to change the temperature setting The 2 digits of temperature on the display will flash Turn the START STOP knob to increase or decrease the value Press button again to confirm the selection or press g START STOP knob to store and run the selection The flashing of TEMP value will stop and the value will be stored automatically if no button is pressed after 6 seconds of the adjustment 5 5 Cooling The temperature can be set from 10 C and 40 C The set Prism R Refrigerated Microcentrifuge 11 temperature can also be changed during the run Note 1 Pre Cooling Pre Cooling starts a temperature control run at 6 000RPM It allows the rotor to be cooled down to the new pre set temperature quickly Cooling down from room temperature to 4 C takes approximately 8 min max 16 minutes To activate Pre Cooling function press and hold button then press 2 START STOP key Both RPM and TEMP icons will flash during Pre Cooling The Pre Cooling can be stopped by pressing the START STOP key The Pre Cooling will function only when the set t
9. before shipping Labnet Quality Control System guarantees that the International Inc performance of the Prism R refrigerated microcentrifuge you have purchased is within its specifications 18 Declaration of Conformity Number CE 00502 Manufacturer Labnet International Inc 31 Mayfield Ave Edison NJ 08837 USA Labnet International declares that the devices described below are in conformity with the EC directives listed In the event of unauthorized modification of any of the devices listed below this declaration becomes invalid Device Name Prism R Refrigerated Microcentrifuge Device Models Numbers C2500 R C2500 R 230V Relevant EC Directives Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC RoHS 2002 95 EC WEEE 2002 96 EC Harmonized Standards EN 61010 1 2010 EN 61010 2 020 2006 EN 61326 1 2006 EN 55011 2007 IEC 61000 3 3 1995 A1 2001 A2 2005 IEC 61000 4 2 1995 A1 1998 A2 2000 IEC 61000 4 3 2006 IEC 61000 4 4 2004 IEC 61000 4 5 2005 IEC 61000 4 8 1993 A1 2000 IEC 61000 4 1 1 2004 July 1 2012 f ob Peter Will Product Line Manager Labnet Labnet International Inc LIMITED WARRANTY Labnet International Inc warrants that this product will be free from defects in material and workmanship for a period of two 2 years from date of purchase This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in the supplied ins
10. centrifuge then to the power source Switch the Power On Off switch to turn on the centrifuge After the LCD display is on and the buzzer beeps twice the centrifuge is ready to operate 3 3 Opening and Closing the Lid The lid can be opened only when the centrifuge is powered on Press button to open the lid The lid will be locked automatically when the user presses down the front edge of the lid Note Do not slam the lid 3 4 Loading the Rotor For safety reasons the rotor must be loaded with centrifuge tubes symmetrically The difference in the weight between the tubes should not exceed 0 1 gram The centrifuge tubes should be loaded in pairs opposite each other and each should contain roughly the equal weight of sample One or two additional loaded tubes may need to be added to achieve this Please refer Figure 1 to see an example of a properly loaded rotor Attention To reduce air friction and noise the rotor lid should be attached to the rotor during centrifugation Make sure that the rotor lid snaps securely into place by pressing down on center catch Prism R Refrigerated Microcentrifuge 5 Securing screw Figure 1 Loading the rotor 3 5 Starting and Stopping a Run Please refer Chapter 5 Operation to set up your preferred settings of time speed and temperature To start a run press down the START STOP knob When the pre set time expires the centrifuge will stop automatically To stop th
11. e centrifuge prior to the expiration of set time press the EJ START STOP knob again When the time is set as continuous the centrifuge will run continuously To stop the continuous run press the 2 START STOP knob By pressing and holding the D button the centrifuge will continue a short run of set speed The short run will stop if the D button is released Note 1 For safety reasons the START STOP knob will be inactivated when the lid is open A symbol g will be flashing until the lid is closed 3 6 Emergency Lid Release When the lid can t be opened by pressing the button users can open the lid manually First turn off the power of the centrifuge Second use a flat head screw driver or other tool to remove the Emergency Lid Release Plug Please refer Figure 2 on the right hand side of the machine Third pull the wire attached to the plug while gently pushing downward on the lid The lid willnow release Prism R Refrigerated Microcentrifuge 7 4 Overview This section presents an overview of the Prism R microcentrifuge s various components and control panel see Figure 2 as well as the symbols and indicators on the LCD display see Figure 3 Power On Off switch amp fuse box Emergency lid release plug Figure 2 Prism R refrigerated microcentrifuge overview Bba Bodo e GO START STOP knob Figure 3 LCD display panel Keyp
12. emperature is lower than the ambient temperature Standby Cooling When the centrifuge is powered on the refrigeration system will cool down the chamber to the pre set temperature before or after the run if the chamber temperature is above the pre set temperature To extend the life cycle of the compressor always remember to inactivate the Standby Cooling by increasing the set temperature above room temperature or power off the centrifuge when it is not in use When the lid is open the Standby Cooling will stop after 3 minutes 5 6 Quick Spin Operation The centrifuge can be operated for a short run by pressing and holding the D button The centrifuge will continue to run as long as the D button is depressed and the time in seconds will count up on the time display The Quick Spin speed and temperature is based on the last run settings remaining in the memory The icon RPM will flash during Quick Spin operation 5 7 Changing the Settings During a Run Users can change the settings while the rotor is running Through a one time pressing of any function buttons 5 j Pa the current value will switch into the pre set value mode The to be changed value flashes and can then be changed Once the display switches into the current value mode after completion of the entered values the new values are activated The new values are stored and executed by pressing the function button again or by waiting 6 seconds
13. n on the length of implied warranties or the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights You may have other rights which vary from state to state No individual may accept for or on behalf of Labnet International Inc any other obligation of liability or extend the period of this warranty Mail Warranty Registration to or Register online at Labnet International Inc www labnetinternational com 31 Mayfield Ave Edison NJ 08837 2 lt cut along the dotted line To validate the warranty complete and return this card within 10 days Model Serial No Date Tested Date Rec d PO Name Title Phone Institution Address City State Zip Postal Code Country Purchased from distributor How would you rate the quality of this product Excellent Good O Fair Poor What feature s on this product made you purchase it What feature s would you change to improve the performance of this product Labnr 31 Mayfield Avenue Edison NJ 08837 Er p 732 417 0700 f 732 417 1750 Labnet International Inc Labnet International Inc
14. ng the screw using the rotor wrench on two holes of the securing screw Please refer Figure 1 Lift the rotor directly upward in a straight vertical motion 14 To replace rotor first make sure the motor shaft and rotor mounting hole are clean Place the rotor on the motor shaft Reinstall the rotor securing screw on the motor shaft by turning it clockwise Hold the rotor with one hand and tighten the rotor securing screw using the rotor wrench 6 6 Replacing fuses Check fuse when it is recommended in the Technical Specifications of this manual The fuse holder is located in the power inlet on the right hand side of the unit Disconnect the power cord from the power inlet Open the fuse holder drawer by inserting a small screwdriver under the tab and prying it open Remove the innermost operative fuse from its retaining tabs and replace the fuse if necessary A spare fuse is located in the outer most chamber of the fuse drawer Replace only with a fuse of the exact same value as the original 7 Troubleshooting To ensure the product s quality and performance the Prism R refrigerated microcentrifuge is 100 inspected by the manufacturer Error messages will appear on the display if the Prism R refrigerated microcentrifuge fails to perform the attempted action properly In the case of Error Err messages or faults please refer to the solutions in the following table to clear the error messages or faults If the following solutio
15. ns are not able to resolve the problem please contact Labnet International Inc Service Department to arrange for Prism R Refrigerated Microcentrifuge 15 authorized service Symptom Possible Cause Solution Lig Error Press Close the lid START STOP knob when Lid is open Defective lid lock Call for service sensor LAL Error Tubes are not inserted Load tubes rotor symmetrically in rotor symmetrically imbalance holes Sample liquid in tubes Make sure that the not properly balanced same volume of liquid is in each tube Defective or improperly Call for service adjusted balance sensor Rotor is stuck when a Call for service run starts Centrifuge Lid not closed correctly Close lid correctly cannot be No speed or time has Set speed and or started been selected time although power is on Centrifuge will No power supply e Check power not start source e Check the power cord connection e Check the power cord quality Blown fuse Check the fuse and replace if necessary Lid Lock will not release Defective lid lock Open manually and have unit serviced board No power from PC Call for service Lid lock jammed Call for service Centrifuge receiving power is not See Centrifuge will not start Appendix A Technical Specifications Model C2500 R Max Speed 13 500 rom Max RCF 17 13
16. sy access rotor 24 x 1 5ml Exceptionally quiet and compact Optional StripSpin adapter available for 0 2ml tubes and strips Compact ergonomic design User friendly operation interface Quick button for instant run without setting Low noise level Complies with CE RoHS 3 Getting Started 3 1 Unpacking The centrifuge is delivered in an external carton and an internal carton with protective PE foam cushions Remove the centrifuge from each carton All packaging should be retained until it has been established that the centrifuge is working properly Prism R Refrigerated Microcentrifuge 3 Open the Prism R refrigerated microcentrifuge package and confirm that all items are included e Prism R unit with a 24 x 1 5 2mle Operation manual rotor and a rotor lid Electric fuses 7A amp 3 15A e Warranty card Rotor wrench e Power cord If there are any items missing damaged or not according to your order please contact your distributor or sales representative immediately Note Please use 7A fuse in power source 100 120 50 60Hz countries while 3 15A fuse is for power source 200 230V 50 60Hz countries 3 2 Initial Operation Place the machine on a stable flat table Please keep the machine at least 30 cm from the surrounding area or objects Mains power and frequency MUST be compatible with the information given on the product label on the rear of the centrifuge Connect the power cord to the power socket of the
17. truction manual Should this product require service contact Labnet International Inc s Service department at 732 417 0700 to receive a return authorization number and shipping instructions Products received without proper authorization will be returned All items returned for service should be sent postage prepaid in the original packaging or other suitable carton padded to avoid damage Labnet International Inc will not be responsible for damage incurred by improper packaging Labnet International Inc may elect for onsite service for larger equipment This warranty does not cover damage caused by accident neglect misuse improper service natural forces or other causes not arising from defects in original material or workmanship This warranty does not cover motor brushes fuses light bulbs batteries or damage to paint or finish Claims for transit damage should be filed with the transportation carrier ALL WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION OF 24 MONTHS FROM THE ORIGINAL DATE OF PURCHASE LABNET INTERNATIONAL INC S SOLE OBLIGATION UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT AT LABNET INTERNATIONAL INC DISCRETION OF A DEFECTIVE PRODUCT LABNET INTERNATIONAL INC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE COMMERCIAL LOSS OR ANY OTHER DAMAGES RESULTING FROM THE USE OF THIS PRODUCT Some states do not allow limitatio