Mercury iTC and iPS Application and Firmware

image

Contents

1. INSTRUMENTS sas O FORD The Business of Science Mercury Support Oxford Instruments tel 44 0 1865 393311 fax 44 0 1865 393333 Mercury System Update email helpdesk nanoscience oxinst com www mymercurysupport com Issue 04 F W Update EngMode Figure 2 Factory Setting Tab 3 Application update 3 1 Plugin USB flash drive to the USB slot located at the back of Mercury unit 3 2 Power up the system if the system is already running wait approximately 5 seconds for the flash drive to be detected and scanned This is a background process and no information will be displayed to the user 3 3 Tap Settings button on Home Screen as shown in Figure 1 3 4 Using right arrow button in the top right corner scroll the Settings window to the F W Update tab tap once F W Update to make it an active view see Figure 3 Settings F W Update EngMode Factory Firmware Device Firmware File aii EOR ON Figure 3 F W Update Tab 3 5 Tap Firmware Device drop down selection once press APPLICATION and then OK button to confirm your choice 3 6 Tap Firmware File drop down selection and tap cryosys_update tar file this will highlight the name of the file tap OK button to confirm 3 7 Tap Apply button and confirm that you wish to start the update process by pressing OK button on the message pop up window 3 8 At the end of the process the system will automatically reboot 3 9 On system reboot the user migh
2. be displayed Mercury ITC system can contain up to 10 devices namely DB1 DB2 DB3 DB4 DB5 DB6 DB7 DB8 MBO MB1 Mercury IPS will have additional magnet devices named PSU M1 PSU M2 etc your system may only contain some of the devices e g only motherboard devices MBO and MB1 in its basic configuration 4 4 Tap onthe name of the device you wish to update e g DB1 and tap OK button to confirm your selection 4 5 Tap Firmware File drop down list select available file and press OK button to confirm 4 6 Click Apply button and then confirm that you wish to update the device by pressing OK button on a message pop up window 4 7 Ifthe device fails to update the firmware an error message will be displayed on a pop up window In such case please tap OK button and then Apply button and try the update process again 4 8 Ifthe firmware on the selected device is successfully updated user should follow steps 4 3 to 4 6 to update the firmware on all available devices in the system 4 9 After all the devices have been updated power the system down wait 30 seconds and power the system up again INSTRUMENTS rr Q FORD The Business of Science Mercury Support Oxford Instruments tel 44 0 1865 393311 fax 44 0 1865 393333 Mercury System Update email helpdesk nanoscience oxinst com www mymercurysupport com Issue 04 4 10 On system reboot the user will be presented with a series of pop up messages informing abou
3. support document 1 to view the list of devices installed in your system A Always update APPLICATION to the latest version before updating the firmware on the devices For help and support please email helpdesk nanoscience oxinst com The full update process consists of the following steps Downloading the update package Saving current settings Application update Device firmware update ae eS Hardware calibration 1 Downloading the update package 1 1 Login to your account at mymercurysupport com and navigate to http mymercurysupport com downloads firmware if you do not have an account request one at http mymercurysupport com user register 1 2 Download the latest Release update package e g Release 1 0 12 1 3 Unzip the release package to any folder on your computer INSTRUMENTS e Q POROJ The Business of Science Mercury Support Issue 04 Oxford Instruments tel 44 0 1865 393311 fax 44 0 1865 393333 Mercury System Update email helpdesk nanoscience oxinst com www mymercurysupport com 1 4 Copy the unzipped files from your computer directly onto a USB flash memory drive Please ensure that your USB memory flash drive contains the following files cryosys_update tar auxPort a43 heater a43 levelMeter a43 magnetPowerSupply a43 tempPressureSensor a43 and tempSensor a43 These files need to be placed directly on your USB drive without any folder or subfolder e g E cryosys_upd
4. Mercury Support Oxford Instruments tel 44 0 1865 393311 fax 44 0 1865 393333 Mercury System Update email helpdesk nanoscience oxinst com www mymercurysupport com Issue 04 Mercury iTC and iPS Application and Firmware updates via USB This document presents guidelines to application software and device card firmware updates for Mercury systems To distinguish between these two types of updates the terminology for application and firmware is explained below Mercury Application is computer software that runs on the Mercury system and enables the user to interact with the system using the touch screen it translates and communicates user commands to appropriate devices on the system The user is able to control the behaviour of the Mercury systems via this application To view the application version installed on your system please follow the guidelines in support document 1 Firmware is a small program that is embedded into the Mercury system s devices hardware cards which includes devices on the mother board Each Mercury system consists of different devices such as a heater or temperature sensor Firmware dictates the correct behaviour of the underlying device when the user issues a command to that device On Mercury systems devices will be listed as MB or DB for mother and daughter boards cards respectively with appropriate symbols e g MBO H1 for heater MB1 T1 for temperature sensor Please follow guidelines in
5. ate tar None None None None None None Figure 1 Home Screen 2 Saving current settings This step is optional it allows you to restore current configuration should the system fail the update process 2 1 Power up Mercury system 2 2 Tap Settings button on Home Screen as shown in Figure 1 If your system has a customised Home Screen e g Cryojet or Heliox system the Settings button shown in Figure 1 can be accessed by tapping on the arrow button in the bottom right corner and then confirming by pressing OK button on a message pop up window A window similar to the one presented in Figure 1 should now be displayed This window consists of six framed channel summary panels for detailed description of the panels please refer to Mercury User Manual 2 3 Verify that the Remote Access is set to Local if it is not tap once Remote Access drop down menu select Local confirm by tapping OK button and press Apply button 2 4 Using right arrow button in the top right corner scroll the Settings window to the Factory tab tap on the Factory to make it an active view see Figure 2 2 5 Tap Enter name box to bring up an alphanumerical keypad window 2 6 Enter the name under which you want to save current configuration e g backup1 and press OK or RET button to exit the keypad window 2 7 Tap Save Configuration button and then press OK button to confirm your action 2 8 Tap Home button to return to Home Screen window
6. ort com List of Figures Settings None f None F W Update EngMode None o None None Control Settings Eg Heater mi 2 Home Screen Settings F W Update EngMode Cal Update F W Update New updates have been applied Firmware Device Save Changes Revert Changes Firmware File FF gt poe p ES E3 C3 E3 4 r Figure 3 F W Update Tab Figure 4 Save or Revert New Updates Page 6 6 INSTRUMENTS The Business of Science
7. t be presented with a series of pop up messages informing about the changes to system configuration Please reject all the changes at this stage by tapping Cancel button on the message box INSTRUMENTS meats O FORD The Business of Science Mercury Support Oxford Instruments tel 44 0 1865 393311 fax 44 0 1865 393333 Mercury System Update email helpdesk nanoscience oxinst com www mymercurysupport com Issue 04 Please note that any APPLICATION updates will be automatically reverted to the previous version on the next system reboot unless the new changes are accepted 3 10 Accept Firmware update after the system has rebooted go to F W Update tab as described in steps 3 3 and 3 4 and tap Save Changes button presented in Figure 4 Alternatively to reject new updates tap Revert Changes button 3 11 Tap Home button to return to Home Screen window Cal Update F W Update New updates have been applied Save Changes Revert Changes iai EOR aai Figure 4 Save or Revert New Updates 4 Device firmware update 4 1 With the USB flash drive still plugged into your Mercury unit tap Settings button on Home Screen window shown in Figure 1 4 2 Using right arrow button in the top right corner scroll the Settings window to the F W Update tab press F W Update tab to make it an active view see Figure 3 4 3 Tap Firmware Device drop down selection a list containing devices available on your system will
8. t has not been previously configured such panel is characterised by None nickname and 0 0000 value this will bring Channel Display Configuration window 5 2 2 On Channel Display Configuration window tap on the Devices drop down list select one of the temperature sensors device name with 71 suffix and confirm by pressing OK button 5 2 3 Tap Signals drop down list and select Temperature tap OK button to confirm 5 2 4 Tap Assign button this will bring back Home Screen with the newly assigned channel summary panel 5 2 5 Tap once on the newly assigned channel summary panel on the Home Screen this will bring Temperature Sensor Details screen 5 2 6 Tap Calibration button and confirm your action by selecting OK button on the message pop up window 5 2 7 After the calibration is finished tap Home button to return to the Home Screen 5 2 8 Tap twice on the same channel summary panel as in step 5 2 5 to bring again the Channel Display Configuration window 5 2 9 Follow steps 5 2 2 to 5 2 8 for every temperature sensor present in the system 5 3 Reboot the Mercury system Support Documents 1 http mymercurysupport com sites default files Where can l find firmware version installed on my Mercury pdf INSTRUMENTS Minnis Q POROJ The Business of Science a Pa Mercury Support Poo i Oxford Instruments tel 44 0 1865 393311 fax 44 0 1865 393333 email helpdesk nanoscience oxinst com www mymercurysupp
9. t the changes made to devices configuration Please accept all the changes by tapping OK button on the message box Note if the pop up message indicates a change to None in the device type e g A DB1 type None it means that this particular device DB1 failed to update Please accept this change by tapping OK button on the pop up message and follow again the firmware update procedure for this device only In step 4 5 you will be presented with a list of files selecting appropriate firmware file will be based on the user knowledge of this device e g heater temperature If in doubt please contact our customer support team DO NOT attempt to update the device if you are not certain of its type 5 Hardware Calibration 5 1 Heater calibration the system will calibrate all the heater devices at once 5 1 1 Tap Heater button on Home Screen this will display a list of available heater devices 5 1 2 Tap Calibrate button in the right bottom corner confirm you action by pressing OK button on the message pop up window 5 1 3 Tap Home button to return to Home Screen when calibration is finished 5 2 Temperature sensor calibration temperature sensors are calibrated one by one the temperature sensors can be easily identified by the T1 suffix in the device name e g MB1 T1 DB6 T1 Follow the steps below to calibrate the temperature sensor devices 5 2 1 Tap twice on one of the six channel summary panels presented in Figure 1 tha