Home
DX-625
Contents
1. 1 green point will glimmer when setting is finished Assist key Press J Increase 1 channel eg Led display from d001 to dO02 Press Decrease 1 channel eg Led display from d002 to d001 Press J Increase 6 channels eg Led display from d001 to d007 Press Y Restore back tod 0 0 1 Press ENTER To confirm You can press 4 Y to modify DMX Address directly under DMX mode PS 1 There are 512 start addresses to be set under DMX mode There are series 6 ch output to each DX 625 Eg start address d001 DMX CH 1 6 output start address d0013 DMX CH 13 19 output 2 Users can set the same address for over 2pcs of DX 625 6 Lite Puter Lite Puter ISO 9001 CERTIFIED 3 1 2 TO SET ANALOG MODE X Under ANALOG mode Only ANALOG signal is acceptable and DMX output does not work take the example of 3 1 1 Eg Set ANALOG IN mode to DX 625 STEP 1 Press FUNC 2 gt and LED displays STEP 2 Press FUNC 2 gt and LED displays STEP 3 Press ENTER to confirm and LED displays 7 Lite Puter Lite Puter ISO 9001 CERTIFIED 3 1 3 TO SET OFF MODE xX Under OFF mode DX 625 will not accept any signal take the example of 3 1 2 Eg Set OFF mode to DX 625 STEP 1 Press FUNC 2 and LED displays STEP 2 Press FUNC 2 and LED displays STEP 3 Press ENTER to confir
2. Lite Puter ISO 9001 CERTIFIED DMX 6CH Dimmer Pack User Manual d 4 gt t ass smammnss Ss Lite Puter DXE25 FAR Lite Puter Enterprise Co Ltd Website www liteputer com tw E mail litecom ms2 hinet net Lite Puter ISO 9001 CERTIFIED INDEX THE REGULATION OF SAFE UASGE 2 CHAPTER 1 INTRODUCTION 1 1 Features GTA 025 tie Da a ta ta i Di a cb nenene 3 1 2 Notice before USSR eee ce See cee cee 3 T3 SSPSCHICAMOM roerien aa aaa ap aaa oa a ai DEA au ae lia E ii 3 CHAPTER 2 INSTALLATION 271 Front PANNE danse ana 4 2 2 Rear FANS on SR eu 4 CHAPTER 3 FUNCTION 3 1 DMX ANALOG OFF mode setting neeeeeeeeeeeeenene eneee 5 3 1 1 To set DMX mode cs aie na ai a an a a 5 3 1 2 To set ANALOG mode sus 7 3 1 3 To set OFF MONS memes 8 3 2 How to connect over 2 PCs of DX 625 ssssssssrrrrrrrrreesennnn 9 3 3 Dimming Switch mode setting ss 10 3 4 Warm Up 0 10 11 3 5 How to supervise the dimming level for each channel 12 3 6 Dimming level testing for each channel or all channels 12 3 7 Fade in and Fade out automatically testing for each channel or all channels 13 3 8 How to set C2 C3 dimming level 14 3 9 Display internal temperature 14 QUALITY CERTIFICATION EE adi mada ma aa a a 15 1 Lite Puter Lite Puter ISO 9001 CERTIFIED The re
3. fade in fade out test and bright level output test for all channels or individual channel LED indicators it displays the working situation of each channel and inner temperature etc Temperature control and heat sink system the power will be switched off automatically when over heat 1 2 Notice before using Make sure that ch 1 ch 6 is connected with AC power especially the channel 1 because it is not only the inspective point of power phrase and also the power source of the main control board 1 3 Specification 3 Specification m Power AC100 240V 45 63Hz 102W 103W 303W 304W m Output Maximal 20A for each channel Please refer to the user manual m DMX signal input output DMX512 1990 m DMX signal connector XLR SPIN M Analog signal input DC 0 10V m Analog connector DIN 8PIN E Dimension 482 W x 88 H x 300 D mm m Rack size 19 2U rack mountable m Weight 7 2Kg DIN 8 PIN CONNECTOR START ADDRESS a 3 Lite Puter Lite Puter ISO 9001 CERTIFIED Chapter 2 Installation 2 1 FRONT PANEL 6 5 2 1 DX 625 6 CHANNEL DMX DIMMER PACK JET DU za Sa T 000000 11 10 9 8 7 4 3 1 ON OFF SWITCH 7 CONFIRMATION KEY 2 DMX SIGNAL OUT 8 FUNCTION KEY 3 DMX SIGNAL IN 9 FUNCTION KEY 4 ADJUSTABLE KEY 10 HIGH SPEED BREAKER CH4 CH6 5 INDICATOR 11 HIGH SPEED BREAKER CH1 CH3 6 LED DISPLAY 2 2 REAR PANEL CH 1 must be given AC power because it provides the working electric power t
4. 3 9 Display internal temperature FUNC 6 DX 625 can display internal temperature to prevent from overheat to control the operation Operation Press FUNC 6 to display internal temperature 1 When the internal temperature is over 37 C the fans start to work 1 minute and stop 1 minute in turn 2 When the internel temperature is over 41 C the fans turn continously 3 When the internal temperature is over 75 C all outputs will be stopped Please check if it is overloaded and the dimmer rack is stuffy 14 Lite Puter Lite Puter ISO 9001 CERTIFIED Quality certification Each DX 625 must be detailed specificated before shipping LITE PUTER offers 2 years guaranty for repairment free of charge under normal usage Transportation fee will be charged for repairment by engerineer service in your place Spare parts cost will be charged for the machine over 2 years The repaired machine sent back must keep everything complete the change of its CPU or PCB inside is prohibited DX 625 EUM B 15 Lite Puter
5. IED 3 4 Warm up 0 10 FUNC 4 EG Warm up 6 0 for channel 1 Operation Press FUNC 4 and press 4 gt to channel then press 7 to adjust the warm up value Press ENTER to confirm STEP 1 Press FUNC 4 and LED displays All channles Dimmer warm up value 0 10 0 STEP 2 Press gt and LED display CH 1 STEP 3 Press to adjust the warm up value to 6 V Warm up value Assist key Press gt Increase 1 channel Press lt Decrease 1 channel Press Increase warm up value Press Y Decrease warm up value 11 Lite Puter Lite Puter ISO 9001 CERTIFIED 3 5 How to supervise the dimming level for each channel FUNC 1 EG To supervise CH 1 dimming level Operation Press FUNC 1 and press 4 J or gt to CH 1 then it will show what you set in section 3 4 VY CH 1 warm up dimming level 6 0 max 10 0 Assist key If one of channels dimming level is tested Press J Increase 1 channel Eg From 0 1 0 0 to 0 2 0 0 Press Decrease 1 channel Eg From 0 2 0 0 to 0 1 0 0 3 6 Dimming level testing for each channel or all channels FUNC 1 EG Test CH 1 dimming level Operation Press FUNC 1 and press or to Ch 1 then it will show what you set in section 3 4 Please turn off DMX signal input before executing this function Tes
6. gulations of safe usage To ensure the normal and perfect working of DX 625 as to the load capacity please refer to our suggestions as below 1 Maximum output of individual channel is 20A For the moments testing About 10 minutes 2 Output of individual channel lt 16A For several hours It s used for a theater or a stage 3 Output of individual channel lt 12A Continue working for the whole years It s used for hotels or restaurants 4 Individual channel must be set dimming or switching function before the load switch circuit breaker turns on The non dimming lamp may be damaged in dimming function Please refer section 3 3 2 Lite Puter Lite Puter ISO 9001 CERTIFIED Chapter 1 Introduction 1 1 Features of DX 625 Each channel auto detected the phase of electric power individually It s not necessary to consider the phase of electric power No matter 101W 193W 303W 304W each phase can be applied to any channel without the problem if connecting phases Please note that the voltage through the loads must be the same to the AC voltage Auto tracking of electric power frequency from 45 to 63 Hz SSR Solid State Relay inside easy for maintenance All channels or individual channel can be set as on off or dimming function Warm up set the warm up level 0 10 can be set to all channels or individual channel Can choose C2 Square or C3 Linear dimming curve Self test function
7. m and LED dispalys PS DX 625 will show the mode chosen before turning off For example if DMX mode was selected then DMX mode continues when system is turned on 8 Lite Puter Lite Puter ISO 9001 CERTIFIED 3 2 How to connect over 2 pcs of DX 625 eee DX 625 ss HE D 9 i de PIN and PIN3 are d 0 0 BS parallel 200 OHM register Lite Puter nx 625 sonne cnx acea pace HE HNA PEE unea Z 44 24 a4 sa 64 DMX CONSOLE IN In order to make sure the realiability of long distance signal transfer over 100 meter gt please connect with 200 OHM terminal resistor PIN2 PIN3 ON the last DX 625 output 9 Lite Puter Lite Puter ISO 9001 CERTIFIED 3 3 Dimming switch mode setting FUNC 3 Operation Press FUNC 3 Jand press the key to change dimming switch mode Then press ENTER to confirm AL means all channels a means dimming mode AL means all channels lt D l d means switching mode Under SWITCHING mode there are no dimming warm up functions and it shows OFF dimming level 0 FL 100 only For FL status the dimming level given must over 51 to light it up For OFF status the dimming level given must under 20 to turn it off Assist key Press gt Increase 1 channel Set individual channel Press lt Decrease 1 channel Set individual channel 10 Lite Puter Lite Puter ISO 9001 CERTIF
8. o the DX 625 7 4 mo O oy Oo AC INPUT 100 240VAC __45 63HZ AC OUTPUT 20A MAX PER CH 1 AC POWER INPUT OUTPUT TERMINAL 3 FAN 2 ANALOG SIGNAL INPUT 0 10VDC 4 Lite Puter Lite Puter ISO 9001 CERTIFIED Chapter 3 Function FUNC 1 1 FADE IN OUT TESTING 2 DIMMING LEVEL TESTING 3 DIMMING LEVEL MONITOR FUNC 2 TO SET ANALOG DMX OFF SIGNAL IN FOR EACH CHANNEL FUNC 3 TO SET DIMMING SWITCH FOR EACH CHANNEL FUNC 4 TO SET WARM UP 1 10 FOR EACH CHANNEL FUNC 5 TO SET C2 C3 DIMMING CURVE FUNC 6 TO MONITOR THE INTERNAL TEMPATURE OF DX 625 REMARK FUNC 1 means holding the FUNC key and press number 1 key 3 1 DMX ANALOG OFF mode setting FUNC 2 3 1 1 TO SET DMX MODE X Under ANALOG mode DMX 512 dimming signal is acceptable Eg Set Ch 7 to be the start address for DMX IN Operation Press FUNC 2 each time gt LED will display as follows d 0 0 1 A E 0 6 gt 0 F F DMX mode ANALOG mode OFF mode STEP 1 Press FUNC 2 and LED displays 4 gree glimmering points are waiting for being set 5 Lite Puter Lite Puter ISO 9001 CERTIFIED STEP 2 Press gt and LED displays STEP 3 Press ENTER to confirm and Ch 7 will be set the start address for DMX IN start address of DMX signal
9. t ch 1 Dimming level output 12 Lite Puter Lite Puter ISO 9001 CERTIFIED Assist key Press Increase 1 channel Eg Led displays from 0 1 0 0 to 0 2 0 0 Press Decrease 1 channel Eg Led displays from 0 2 0 0 to 0 1 0 0 Press Increase dimming level Press 7 Decrease dimming level 3 7 Fade in and Fade out automatical testing for each channel or all channels FUNC 1 Operation Press FUNC 1 Jand press gt gt to choose the channel number and execute test function The machine will restore the previous situation automatically after one minute This function will be cancelled automatically when DMX ANALOG input BART Automatic Fade in and Fade out All channels Assist key Press gt J Increase 1 channel 1 gt 2 gt 3 gt 4 gt 5 gt 6 gt AL Press lt Decrease 1 channel AL gt 6 gt 5 gt 4 gt 3 gt 2 1 The function will be stopped when you choose another function 13 Lite Puter Lite Puter ISO 9001 CERTIFIED 3 8 How to set C2 C3 dimming level FUNC 5 C2 curve To show the exact linear relation between dimming and output please check the diagram below C3 curve It is suitable for stage lighting the voltage is in linear proportion to the corol level Operation Press FUNC 5 and press Jor gt to choose C2 C3dimming curve then press ENTER to confirm
Download Pdf Manuals
Related Search
DX 625 dx625.cc dx625x dx 605 dx r6250 dx r6251 dx r6252 dx 62 3-d dx g250 dx g2581 dx6265 modem
Related Contents
HSM Classic 450.2 2x15mm ALTAIR-P - Garajes Prefabricados SAS Brodit ProClip 654820 53d2dbfd8520f1ecd420090fe23a2087 取扱説明書 Papiers à articuler Bausch Copyright © All rights reserved.
Failed to retrieve file