1.
2. 14 6 UPLOAD RESULTS AND CURVES 8 As ET ten 14 6 1 Scanning the network 8 132 Factory Assembly line Working area 14 6 2 Adding a controller 8 6 3 Uploading a controller database 8 14 SOFTWARE VERSION 14 7 TIGHTENING RESULTS DISPLAY 9 BEPROFIE esse see se see Se EE EER 10 6159939231 03 02 2014 3 Original instructions Copyright 2014 Desoutter HP2 7SJ UK All rights reserved Any unauthorized use or copying of the contents or part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings Use only authorized parts Any damage or malfunction caused by the use of unauthorised parts is not covered by Warranty or Product Liability 1 STATEMENT OF USE This product is intended to analyze tightening data with results curves filters profiles amp import export No other use permitted For professional use only 2 INSTALLATION 2 1 Recommended system requirements Windows XP operating system 150 Mo available on hard disk Monitor resolution 1280 x 1024 Administrator rights required for installation Connection to an Ethernet network 2 2 Installation e Insert the supplied USB key or CDrom and follow the instructions e If the installation does not start automatically go to the explorer at the root of the
3. Software install Public key PC name At the bottom of the screen paste your public key enter a name for customizing the PC name up to 40 characters and click Submit You will get then the registration code Launch the software CVI CONFIG for example e In the Menu area click Registration Registration Part number 615927CVICO4LUSE Serial number Licence number Public key 19AD9449F7DC33A4131C70ADD E copy Registration code Registration link https licensing desouttertools com Ext e Copy paste the registration code 6159939231 03 02 2014 e Click Register to validate In this example the software is to be used for 1 user If you buy 5 licences you will have to register the software once and activate the registration code on 5 different PCs e In case of any problem login to the website www desouttertools com licensing and click this icon to contact Desoutter support Contact Form 2 6 How to uninstall the software e From your PC desktop go to Start Control Panel Programs Programs and Features e Double click the program that you want to remove e If you are prompted to confirm the removal of the program click Yes e Once the software removed you will be asked to unregister your licence e Login to the website www desouttertools com licensing e Click this icon to display the following screen
4. ees ese ees kes ee 4 9 FILTER ee ee se 10 9 1 Create your own filters 10 2 INSTALLATION EE nn 4 9 2 Use standard fiters ssostni san 11 9 2 1 Factory Assembly line Working area 2 1 Recommended system requirements 4 A a 11 2 2 Installation ns 4 2 2 ONE AYP Enaisi e s 2 3 Any help EE 4 92 2 8 EINSTONIYPESELINISHINEHTESHN messe 2 3 1 Read the user manuals 2 A 9 2 4 Filter on status ee ee 11 2 3 2 Contact US 4 9 2 9 Filter on PSB scanners 11 2 4 HOW to register 4 RE EE ESS 1 2 5 How to activate the software 5 9 3 One shot filtering pa 11 2 6 How to uninstall the software occcccoo 5 10 CURVES DISPLAY 22u02200000000000 12 J OVERVIEW estadio Ge ee gee ee eise 6 11 REPORTS DISPLAY 12 4 FIRST SETTINGS 7 4 1 Language ees Ee EE RR Re GE Re GE ee GE ER GE Ee ee T 12 BACKUP EXPORT ees ees sees seke 13 4 2 Torque unit T 4 3 Date and time format T 12 1 Save a database ees ee ee RE ee EE 13 12 2 Load a DaEkUP esse EE Ee ENE 13 5 CREATE YOUR ARCHITECTURE 7 12 3 Purge database 13 12 4 Recent files 13 5 1 Factory tool DEE na na as en T 12 5 Export to CSV file EE 13 5 2 Managing items T 13 INFORMATION
5. by uploading a controller database via a USB stick by loading a CVI ANALYZER backup When the maximum size of the database is reached a pop up will show up asking you to backup the database A e Click Purge the database in the menu area Results and curves will be automatically saved in a database in the software directory C Program Files x86 Desoutter CVIAnalyzer but controllers will stay in the same place 6 1 Scanning the network e Click this icon to start the scan a All CVI3 controllers present in the network will be listed Assembly line 4 Assembly line Working area Working area Results number Number of received responses 29 Product Name B SNTOGA104L3 O cvn Fra O 192 168 5 197 Vision Box g cua o CVB Vision O runcva E 192168 6 180 O 1921686181 O 192 168 6 183 B 192 168 6 185 O 192 168 6 186 E TWIN ENDU 192 168 6 190 E TWIN ENDU 192 168 6 194 Select 2 IP address 192 168 5 112 192 168 5 161 192 168 5 197 192 168 5 213 192 168 5 25 192 168 5 32 192 168 6 180 192 168 6 181 192 168 6 183 192 168 6 185 192 168 6 186 192 168 6 190 192 168 6 194 Select All Unselect a w Connection E Exit e In the tree view area select the Factory Assembly line Working area where to add the controllers e Enter the maximum number of results per controller to upload 10 000 by default per tightening unit mi e Click this icon to scan this controlle
6. e Customize the name e Tick All steps or Only last e Tick the information to display The profile is automatically saved Desoullor 9 9 FILTER The filters are used to sort the results A filter can contain several search criteria 9 1 Create your own filters e Click Filter on the bottom left of the screen mar a AA Factory ype Status Tool status Step status Results Profie 4 Filte ns 1634617 1634617 1634616 1634616 1634615 1634615 1634614 1634614 1634613 1634613 1634612 1634612 1634611 CM apply 1634611 Mr e Click this icon to create a new filter up to 10 e Customize the name e Add one or more filters by ticking them one by one Untick the filter you want to suppress the line will turn grey Click Apply to execute the process and display the results The filter is automatically saved ES e Click this icon to delete the filter e See below an example of filtering I Fiteri Filter1 Add fiter Status amp Tightening OK e Tightening NOK vw 1 Stop source No stop 6159939231 03 02 2014 9 2 Use standard filters 9 2 5 Filter on Pset 9 2 1 Factory Assembly line Working area Controller y e From the factory tool bar click this icon to filter by name e Use the following shortcuts from n to m results all numbers 2 to n results a b c e Tick Apply to valid the selection Contains
7. Deg 11 00 50 0 e 18 00 200 Result E N conter TAN WE IG Serial number 27011100318 Date 10 02 2014 12 02 16 Q Software version 157 0 Pset Pset o L 13 EE O O E TE O O N OE Tightening unit Tightening unit 1 Pset version 1 0 gt Tool serial number 11456521 Batch count 0 12 PEER ED DE RA ROER EE A EO Tool comment MY TOOL COMMENT Profile Cable serial number 29101200038 11 hE NW A nera A O EN Filter v Ee Cahla rammant LE Legend Menu area Tool bar Tabs for Results Curves Reports Factory tool bar Results display area Tree view area Details per result Profile and filter areas Curve display area 10 Filter icon 11 Alphabetical sort OO M OO O1 PONS Desouller E g 4 FIRST SETTINGS 5 1 Factory tool bar a to create a factory 1 Language guag e Double click the item to rename it h The language by default is Englis en to add an assembly line Create as many items File Language Settings as you want to add a working area to scan the network All CVI3 controllers present in y the network will be listed to add any type of controller Gi A controller is identified by its IP address e Tick your language a to add results from a database 4 2 7 Torque unit m londres tom dass to view information about the item Help Registration Torque units He Date format Restore default layout to delete the selected item to sort the items
8. Manage existing licenses Tene Install yP date License Management License Number Serial number Software uninstall Software uninstall Uninstall Key Comment r Send an email gt If you have any problem check the reason and click on submit button We received an email and tried to help you as soon as possible Reason Crash disk Forget uninstall Other reason En www desouttertools com e Copy paste the uninstall key that you will find in C CVI CONFIG_uninstallKey txt and click Submit In case of PC crash tick Other reason and add a comment to explain why you want to uninstall your licence Click Submit to validate e Please wait for a message from Desoutter support confirming that your license has been unregistered You will then be able to reactivate the license on a new PC 3 OVERVIEW File Language Settings Help Registration ID eene vetat rl T7 vv Y yv y v eed Factory 10 02 2014 12 03 49 5 1 1 Target reached 1630 12 A v lt P Assembly line v N Working area 1 45 10 02 2014 12 03 48 1 Trigger released CVB Vision E tomers 12024 Tiger ese fr v A Tightening unit 1 v M Tools 10 02 2014 12 02 13 5 Target reached 1 Tic a sa 1 10 02 2014 12 02 11 Trigger released py 1 Ti hs History 10 02 2014 12 01 24 5 Target reached ME A 1 Tic 10 02 2014 12 01 23 Tightening Torque y Target reached Torque N m Angle
9. USB or CDrom and launch the file setup exe la x Industrial O TS CVICONFIG 8 MONITOR CVIANALYZER e Click Install software and then this CVIANALYZER icon to launch the set up wizard Desoullor 9 4 2 3 Any help 2 3 1 Read the user manuals e Click this icon to display the literature available CVI CONFIG user manual A CVI3 FUNCTION user manual CVI MONITOR user manual BEA cv VISION user manual ca CVI3 TWIN user manual CVI ANALYZER user manual 2 3 2 Contact us Contact your Desoutter representative for support e Click Contact us to display the following screen www desouttertools com e Contact your Desoutter representative for support e Click the link to visit our website 2 4 How to register e Launch the software CVI CONFIG for example e Go to the main menu and click Registration Registration Part number 615927CVICO4LUSE Serial number Licence number Public key 19AD9449F7DC33A4131C70ADD LE copy Registration code Registration link https licensing desouttertools com e Enter the serial number You will find them on the Enter the license number label of the packaging box e Go to the website www desouttertools com licensing Dosoultor B Desoutter License Manager e Click this icon to copy the Public key and put it on the Clipboard Industrial The brand new Deso
10. status y Y gt All rm Tightening OK Tightening NOK 6159939231 03 02 2014 11 10 CURVES DISPLAY The number of curves to upload is 20 as a maximum per Tightening Unit N e Click this icon to create a tab up to 1 e Select the result in the list Legend Angle min Torque min Curve type Slope Markers to print the curve to show the Control markers y to show the Monitoring markers to zoom out and return to the initial display ah WN CTR S gt to activate the zoom use the mouse wheel to move on the screen zoom in by sliding the mouse right click to zoom out to draw the slope and display slope values per tool to reset the curve view e Use the mouse to follow the points of the curve A I Ed a Select a type of curve Torque vs angle Torque vs overall angle Time curves Select all steps or step by step 42 Desoullor 9 11 REPORTS DISPLAY e Select any item of the tree e Each time you click this icon a new tab is created up to 5 different tabs Example of display r Results Tightening OK Bi Tightening nok Monitoring 3380 Results 7500 Results Monitor NOK Target reached Torque abort 1 Distribution of tightenings OK NOK 2 Tightening stop source condition histogram 3 Reasons for monitoring NOK 4 Details on Monitoring OK e Tick
11. the Filter tab on the left side of the screen and select one or more filters The filters will limit the size of the results sample Gi It is not possible to change the display 6159939231 03 02 2014 12 BACKUP EXPORT 12 1 Save a database Backup is used to save a complete database controllers results in the software directory C Program Files x86 Desoutter CVIAnalyzer The name is datas dd mm yyyy hh mm ss db by default e Click File then Save in the menu area or press Ctrl S cvi CVI Analyzer Language Settings Help Registration i Database e Save Ctrl 5 ecw Export to CSV file Ctrl W de Load a backup Ctrl B FN Exit Ctri Q Purge database Factory EES Recent files 12 2 Load a backup Pre requisite you already have saved databases by using CVI ANALYZER e Click File then Load a backup in the menu area or press Ctrl B o CVI Analyzer Language Settings Help Registration Database k p Re sow Export to CSV file CtrikW Ra Load a backup Ep Exit Ctrl Q Purge database Factory Recent files 12 3 Purge database e Click File then Purge database in the menu area Y All results and Psets will be deleted Controllers will stay in the same place 12 4 Recent files This function enables you to open the last files you have saved e Click File then Recent files in the main menu Load a backup Ctrl B
12. up to 5 different tabs Status Tool status Step status Results vv 3152891 y Y Y 16 01 2013 18 16 25 3152890 16 01 2013 18 16 23 3152889 16 01 2013 18 16 21 3152888 16 01 2013 18 16 19 3152887 16 01 2013 18 16 17 3152886 16 01 2013 18 16 15 3152885 16 01 2013 18 16 12 3152884 16 01 2013 18 16 10 3152883 16 01 2013 18 16 09 Y P P P P r Fr Fr P P P 3152882 16 01 2013 18 16 06 e Apply profiles and or filters to sort and customize columns and rows e From the list of results select one result and click its row The details of the result are displayed The associated curve is also displayed if available CVI ANALYZER is able to display multiple steps when the user has chosen to store the results of each Pset step e To set this option refer to chapter 10 Step programming General in the CVI CONFIG user manual E Cr e ata ma yp l e set Tool status Step status Pset name I 1 09 04 2013 16 20 26 1 09 04 2013 16 20 26 09 04 2013 16 20 26 09 04 2013 16 20 26 09 04 2013 16 20 26 09 04 2013 16 20 26 09 04 2013 16 20 26 CVI ANALYZER is also able to display results with multiple tools like below with a TWINCVI3 controller Tool status Step status v aad Factory 4 Assembly line v K Working area Tightening unit 1 gt M Tools gt Wu Psets v A Tightening unit 2 gt Wu Tools gt MM Psets 6159939231_03 02 2014 Step number Step number Stop source Y Target re
13. Assembly line Working area 9 2 6 Filter on date Controller Controller type Time Pset Step number Enter the text in the Contains field and tick Apply to valid y Tv Y your selection Configuration User defined v e Repeat the same for the other filters Start 15 01 2013 y 9 2 2 Controller type End 15 01 2013 _ Apply e Select an already existing configuration today yesterday last week etc or create your own e Enter the start end dates Factory e Click Apply to valid the selection Assembly line Working area 9 3 One shot filtering Controller v e From the factory tool bar click this icon and go to the Controller type tag Controller type e Go to the results display area a All E cve Function e Click the filter icons to sort the results as you want O cve vision For example O cva Twin Step status Results e Tick the type of controller to view 7 gt y y 16 01 2013 18 16 25 9 2 3 Filter on type of tightening result Tightening OK 16 01 2013 18 16 25 Tightening NOK 16 01 2013 18 16 23 3152890 16 01 2013 18 16 23 v e From the Results display area click this icon below each column header 3152889 16 01 2013 18 16 21 3152889 16 01 2013 18 16 21 Type Status Tool status 3152888 16 01 2013 18 16 19 E Tightening results Ei Run reverse rfi Batch increment u Hr Batch decrement 9 2 4 Filter on status Status Tool
14. Partno 6159939231 Issue no 03 Series Date 02 2014 Page 1 16 Tools Industrial VI ANALYZER V 1 1 3 X User manual oi CVI Analyzer LA Help Registration File Language Settings 4 Profile Default w Fiter Filter vj Tightening results 1 E Factory Reports 1 Results Curves 1 Step number Stop Type Status or source vv YT v ead Factory Assembly line v 4 Working area_1 gt D CVB Vision gt o CVB Vision y D TWINCVE v A Tightening unit 1 10 02 2014 12 03 49 10 02 2014 12 03 48 10 02 2014 12 02 14 10 02 2014 12 02 13 v N Tools v Tool1 v E History P 10 02 2014 12 01 24 gt 4 Tool2 v N Psets F Pset5 10 02 2014 12 02 11 10 02 2014 12 01 23 Result 44 Tool 1 Step 1 Tightening Torque r Target reached Angle Deg 11 00 50 0 18 00 200 10 02 2014 12 02 16 Torque N m Result Controller TWINCVB Result Serial number 27011100318 Date Software version 1 5 7 0 Pset Pset Tightening unit Tightening unit 1 Pset version 1 0 Tool serial number 11456521 Batch count 0 Tool comment MY_TOOL_COMMENT Cable serial number 29101200038 Cables rammaont Torque N m Trigger released Trigger released 1 Tic 1 Tic Trigger released 1 Tic 1 Tic gt w Trigger released Angle Deg 80 100 bolo colo ita lo ia ly 1 www desouttertools com CONTENTS 1 STATEMENT OF USE
15. Purge database Recent files Default C Program Files x86 Desoutter CVIAnalyzer datas_10_02_2014 09 02 07 db e Click Default to load the CVI ANALYZER database Below is the path leading to the software databases location 6159939231_03 02 2014 13 12 5 Export to CSV file This function enables you to export the results to a CVlAnalyzer Results csv file in C Program Files x86 Desoutter CVIAnalyzer by default e Select a controller in the tree view area e Click File Export to CSV file or press Ctrl W Only results present in the results view will be exported the filters applied are taken into account 13 INFORMATION 14 SOFTWARE VERSION e Click About in the main menu to display the software 13 1 Controller version e Select a controller in the tree view area e Click this icon to display information about the selected item Assembly Ine Working area IP address 192 168 5 25 JLo Software verson Seralmumber C MAC adres Tightening Unit number a e Change the IP address if required it e Click this icon to undo your last edit 13 2 Factory Assembly line Working area e Select an Assembly line for example e Click this icon to display information about the selected item e Type a comment to customize the assembly line 14 6159939231_03 02 2014 Desoullor 93 More Than Productivity www desouttertools com Copyright 2014
16. ached Target reached Target reached Target reached Target reached Target reached Target reached Target reached Target reached Target reached Stop source Target reached Target reached Target reached Target reached Target reached Target reached Target reached Y Y I 09 04 2013 16 16 31 Torque N m Torque N m Time 09 04 2013 16 16 31 09 04 2013 16 16 31 J 09 04 2013 16 15 18 09 04 2013 16 15 18 09 04 2013 16 15 18 Step number Y Stop source y Target reached Target reached Target reached Target reached Target reached Target reached Torque N m y EE EE EST ESA ESA ES TA 8 PROFILE Profiles are used to customize the columns of the result view The user can define the columns he is interested in e Click Profile on the bottom left of the screen The default profile is displayed Fi e Click this icon to create a new profile up to 10 Factory Step status Profile v Pk Profile_11w ES N 1634617 Profile name Profie 1 IE 1634617 Steps a 1634616 e All steps Only last EN Informations 1634616 EN 1634615 1634615 _ Factory 7 Assembly line _ Working area En 1634614 _ Controller _ Controller serial numb _ MAC Address E 1634613 _ Ip address 1 Tightening unit En 1634613 vr Tool 7 IF Pset 1 Results Eh 1634612 Results status 12 Can sis 4 Fy 1634614 1634612 1634611 1634611
17. in alphabetical order to filter per factory and or component of the factory e Select the format 4 3 Date and time format e Select one format in the list below and click Apply to 9 2 Managing items update the results Date format e Right click any item in the tree view area a Info Date format dd MM yyyy V 10 02 2014 Update Collapse Delete O 19214 1 Alphabetical sort Time format Time format HH mm ss 08 46 19 Apply 5 CREATE YOUR ARCHITECTURE to view information about the item to update the results and curves of e Create your own architecture by sorting the controllers in a Update th lected it tree view that match their physical position in the factory EE EI a Rm Collapse to view the main items only A factory is a group of assembly lines a AA S Delete to delete the selected item a An assembly line is a group of working areas O Update last 10 update the last 10 000 results P and curves of the selected item A Alphabetical to sort the items in the tree view Z sort area Pi A working area is a line segment where a specific E assembly action is done lt is composed of controllers 6159939231_03 02 2014 7 6 UPLOAD RESULTS AND CURVES Tightening results and curves can be collected by scanning the network by adding a controller via its IP address
18. r 5 e Click this icon to update the results of this controller in CVI ANALYZER e Click Select all to have them all in the tree view e Click Connection to start e Click Start scan to start a new scan e Click Exit to quit the screen Desoullor 9 6 2 Adding a controller E e In the factory tool bar click this icon to add any type of controller i Add controller eed Factory Assembly line 4 Assembly line Working area Working area Results number IP address e Select where to add the controller factory assembly line working area e Enter the maximum number of results per controller to upload 10 000 by default per tightening unit e Enter a valid controller IP address e Click Select to start e Click Exit to quit the screen 6 3 Uploading a controller database e Plug the USB stick into the PC uci In the factory tool bar click this icon to start ead Factory 4 Assembly line Working area Import CVi3 database CVI3 databases directory e Select where to add the new controller factory assembly line working area e Enter the controller name 40 characters al e Click this icon to display the directory where you have saved the database e Press OK to validate 6159939231_03 02 2014 7 TIGHTENING RESULTS DISPLAY e Each time you click this icon a new tab is 220000 created
19. utter License Manager is your privileged interface to manage 7Days 24h your license numbers The online application enables you to E Create an account Register your Desoutter products Unregister your Desoutter products Follow up your current registrations Lost password www Cesouttertools com e Click Create an account fill in the form and click Submit e You will receive a confirmation by e mail 6159939231 03 02 2014 e Check your mail and follow the instructions e Go back to the website www desouttertools com licensing e Enter your login and password and click Submit e Click this icon to display the following screen License Management License management Add a new license Serial number License number Submit You will find them on the label of the packaging box e Enter the serial number e Enter the license number e Click Submit to validate 2 5 How to activate the software e Login to the website www desouttertools com licensing e Click this icon to display the following screen License Management Manage existing licenses Install License Number date Type Serial number Software install License card License type Part number ZZZZZZZZZZZZZ Software designation ZZZZZZZZZZZZZ Installs 1 License Serial number License Number Date manufacturing 01 05 2012 02 44 38 Installs remaining 1 Features