dotLINK User`s Guide
Contents
1. Enter the dotLINK Static IP Address Network name ira or if using DHCP the Device Name 192 52 153 61 atres in this field Port number s Acquisition server Description Cancel am Port number s to be added list and or range For Client Server only Select the server computer you want to associate with the port from the Acquisition server list You can select any valid Acquisition Server that is part of your TotalChrom system configuration After you select a server to associate with an acquisition port that server is designated as an acquisition server in the System tab Enter a description of this port in the Description text box if desired The port description is intended to assist TotalChrom users in identifying this port during the physical instrument configuration process Add this port to the system and close the dialog box or continue to add additional dotLINK s e To add this port to the system without closing the dialog box choose Apply This adds the port to the system but does not clear the dialog box You can then add another port to the system e To add this port to the system and close the dialog box choose OK e A serial port can be added and configured similarly by selecting Serial as the Device type and entering 1 or 2 as appropriate for the COM port number 21 Configuring TotalChrom Acquisition Ports to use dotLINK Ports Tab Display The following example shows a
2. 37 38 50 51 52 dotLINK Error Messages Device expected here not file An operation was attempted on a file that is only allowed for a device such as setting Baud rate with the MODE command Illegal character found in string Probably result of bug in IPM or dotLINK EPROM BIN is in use This error results if the Host computer tries to erase BINERASE or download to BINCOPY an IPM while it is in use still INSTALLED Probably result of bug in Host software Circular input buffer overflowed Probably result of data arriving at port before the IPM was installed Could be result of bug in IPM Instrument does not respond Probably result of instrument being turned off Could be result of disconnected RS 232 cable Command is out of sequence This error results when certain commands are given before prerequisite commands are given Probably result of bug in Host software Interrupt not serviced fast enough Too much data arrived at instrument port for the CPU to handle Probably result of bug in dotLINK EPROM or bug in IPM Handle does not exist Probably result of bug in Host software Command not recognized Probably result of bug in Host software Could be result of corrupted IPM Record is too long for buffer Probably fault of RS 232 communications Ran out of Handles This is probably the result of a task that asks for handles from the dotLINK Operating System but neglects to give them bac
3. F Static IP IP Address C DHCP Set IP config Network Mask Gateway Device Name This returns a DHCP address from the network NOTE DHCP addresses cannot be used as Static IP addresses You must delete the displayed DHCP address and enter your Static IP address 5 Enter the Static IP Address Network Mask and a unique Device Name supplied by your Network Administrator and select Static IP Fs z IcarusiPConfigure MAC Address foo eo 3c oo oo o0 Get IP config IP Address E bet Set IP config 0 Network Mask Gateway Device Name If you are connecting between two networks sub networks or virtual LANs contact your Network Administrator for a Gateway address and enter it in the space provided 16 Chapter 2 Installation Setting Up dotLINK for Ethernet If you are not connecting between two networks sub networks or virtual LANs leave the Gateway field blank z IcarusiPConfigure MAC Address 00 feo fse foo foo fon Get IP config Status Configuration IP Address Network Mask Device Name 6 Next click the Set IP Config button All configuration fields should remain populated If the Status displays Received reply the dotLINK is now configured with a Static IP Address 17 Setting Up dotLINK for Ethernet How to Configure dotLINK for Direct Ethernet Connection to a Computer When you connect directly to a host computer not on a netw
4. The line cord plug should only be inserted in a receptacle provided with a protective earth contact The protective earth ground contact should not be disconnected for any reason To do so may interfere with the proper operation of the dotLINK The dotLINK will operate at any line voltage between 100 and 240 VAC The AC power plug is the disconnecting device for the dotLINK standalone Do not position the dotLINK so that it is difficult to remove the power plug from the AC mains outlet Available Power Cords Old British Standard BS 546 India 0999 1423 North America NEMA 5 15 0998 8986 Europe British Standard CEE7 BS 1363 Schuko United Kingdom 0999 1415 0999 1414 Europe Australia Switzerland ETSA S 86 0999 1413 0999 1417 Europe Italy 0999 1422 Denmark 0999 1416 NOTE Disconnect the power cord from the AC receptacle before proceeding 6 Chapter 2 Cables Cables The communication cables required for dotLINK are serial cables and Ethernet cables e The serial cable consists of RJ 45 plug dotLINK end and DB9 female computer end The serial cables are available in 5 ft 10 ft and 25 ft lengths e The Ethernet cable has RJ 45 plugs on both ends Front Panel Standalone The standalone dotLINK front panel contains six status LEDs corresponding to the six possible connections to the rear of the box gt andin A B C ae u LINK O O O O00 D E F Each LED shows t
5. TotalChrom Ports tab in System Configuration System Configuration Active Configuration Eile System Printers Servers Ports Instruments Job Types Users View Help Sa el Be als gE ale 917 15 2 a System Printers Servers Ports Instruments Job Types Users Acquistion ports device port number E INTX Network name port number NR a IP address Communication type Terminal Server Acquisition server fwashington Description forLCinab T Attached interface AAA Attached instruments The instruments attached via this port Active MODIFIED NUM The Acquisition Ports list displays all configured acquisition ports The device names and port numbers are displayed in a hierarchical tree format similar to the directory display in the Windows Explorer To access a shortcut menu of functions right click anywhere in the Acquisition Ports list When you select a specific port number from the acquisition ports list you can display detailed configuration information on the port and any devices that are attached to the port is displayed For Client Server only You can change the acquisition server for a terminal server port by selecting the desired server from the Acquisition Server list You can change any port description by modifying the data in the Description field To change any other configuration information about a port such as its name or port number you must delete th
6. bin symbol and a rectangular bar indicates that the product is covered by the Waste Electrical and Electronic Equipment WEEE Directive and is not to be disposed of as unsorted municipal waste Any products marked with this symbol must be collected separately according to the regulatory guidelines in your area The objectives of this program are to preserve protect and improve the quality of the environment protect human health and utilize natural resources prudently and rationally Specific treatment of WEEE is indispensable in order to avoid the dispersion of pollutants into the recycled material or waste stream Such treatment is the most effective means of protecting the customer s environment Requirements for waste collection reuse recycling and recovery programs vary by regulatory authority at your location Contact your local responsible body e g your laboratory manager or authorized representative for information regarding applicable disposal regulations Contact PerkinElmer at the web site listed below for information specific to PerkinElmer products Web address http www perkinelmer com Customer Care 1 800 762 4000 inside the USA 1 203 925 4602 outside the USA 0800 40858 Brussels 0800 90 66 42 Monza Products from other manufacturers may also form a part of your PerkinElmer system These other producers are directly responsible for the collection and processing of their own waste products under the terms
7. defective SRAM chip s Could be result of bug in Host control program Syntax error on command line Although dotLINK recognized the command the parameters on command line do not make sense Probably result of bug in Host control software Could be result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Cable not connected Probably result of cable not plugged into dotLINK port Could be result of an improperly wired RS 232 cable STOP command was given The STOP command does not apply to instrument control and thus should never be issued to an IPM Probably result of bug in Host control software Binary data not allowed here Probably result of bug in Host control software Not allowed in an INVOKE file Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM BIN library is not compatible Probably result of using an out of date dotLINK EPROM or an out of date IPM Could be result of corrupted IPM BIN library is corrupted or not available Probably result of corrupted IPM Command line parameter is out of range Probably result of bug in Host software Could be result of bug in IPM or dotLINK EPROM BIN module not found in any of the libraries dotLINK could not find the IPM given in the INSTALL command Probably result of bug in Host software Chapter 4 Technical Data 31 32 33 34 35 36
8. of corrupted IPM Could be result of bug in dotLINK OS EPROM Illegal calling parameters A Task tried to write to a file that had not been opened yet Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Ran out of memory dotLINK is not supposed to begin a run if there would not be enough space to hold all the data Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Ran out of directory entries dotLINK has a limit of 512 files This error could result from a lot of very short runs Probably result of connecting too many instruments to dotLINK Could be result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Ran out of Task Control Blocks This is probably the result of a task which creates new tasks but fails to return Task Control Blocks to system when done May require that the rogue task execute several times before error occurs Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Chapter 4 Technical Data 13 14 15 16 17 18 19 20 21 dotLINK Error Messages Memory Pool does not exist for this file This error should never occur Unexpected end of file or device timed out Probably result of communications failure via Serial Port Could be result of bug in IPM Co
9. to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which user will be required to correct the interference at their own expense NOTES 1 Changes or modifications not expressly approved by PerkinElmer could void the user s authority to operate this product 2 The product is not designed for use in a residential environment Safety and Site Data for dotLINK Standalone EMC Directive European Union All information concerning EMC standards is in the Declaration of Conformity and these standards may change as the European Union adds new requirements The dotLINK standalone for use in the European Union is intended for the industrial environment The product is to be connected to a main power network supplied from a high or medium voltage transformer dedicated for the supply of an installation feeding a manufacturing or similar plant Industrial environments are characterized by the existence of one or more of the following conditions e industrial scientific and medical ISM apparatus are present e heavy inductive or capa
10. 4 Updating dotLiINK Software eeose eoi reser ene anien eiers 26 Verifying the Software Update nsike reee ai ariere e E 27 Chapter 4 Technical Data Functional DeSCriptiOn AAA sense en 29 dotLINK Personality board 22 22002200000s0nesnnesnnesnnesnensnensnensnennnnnnnnnnnnnennennnennnennnennnn 29 Ci aan Hrn o ETEA EE EE EAEE ES 29 Eleetronicsi 2d RE 29 MICTOPTOCES SOL pia 30 Permanent Borde 30 Temiporary OA ia 30 Ethernet a a a e ta BAS a Ele dd o 30 SN 30 Troubleshooting Guide 2 2 2 24 2 22 52088888828 basE RA lead init 31 dotLINK Error Mess ges 2 220s22 2 0 810 st sats oi ches csvescsccsvebagevas Eer EAEE i a Pea EERS einans 33 Warranty ServiCO iia An 39 Specifications net di 39 Index ii Table of Contents Chapter 1 Introduction The PerkinElmer dotLINK Interface is used with PerkinElmer software products to acquire and buffer digital data from laboratory instruments and to control the operating parameters of such instruments The dotLINK Interface is available in two forms standalone and integral The standalone modules connect to the host computer directly or through a network hub or terminal server and to the controlled instrument The Integral dotLINK is a version of dotLINK that is installed inside selected PerkinElmer GCs Each standalone dotLINK module can simultaneously communicate with up to three instruments Each Integral dotLINK module communicates with the single instrument in which it is ins
11. CHROMATOGRAPHY SOFTWARE dotLi NK User s Guide gt PerkinElmer precisely Congratulations on your purchase Please take a few minutes to register your dotLINK online at http www perkinelmer com dl As a registered PerkinElmer customer you will be the first on our list to receive information on new products enhancements or software updates dotLINK User s Guide Release History Part Number Publication Date N515 6088 July 2005 Any comments about the documentation for this product should be addressed to User Assistance PerkinElmer 710 Bridgeport Avenue Shelton CT 06484 4794 Or emailed to info perkinelmer com Notices The information contained in this document is subject to change without notice Except as specifically set forth in its terms and conditions of sale PerkinElmer makes no warranty of any kind with regard to this document including but not limited to the implied warranties of merchantability and fitness for a particular purpose PerkinElmer shall not be liable for errors contained herein for incidental consequential damages in connection with furnishing performance or use of this material Copyright Information This document contains proprietary information that is protected by copyright All rights are reserved No part of this publication may be reproduced in any form whatsoever or translated into any language without the prior written permission of PerkinElmer Inc Copyrig
12. If you are using a serial port to connect dotLINK you must know the COM port number Only one COM port can be used per computer and the port itself must either be COM port 1 or COM port 2 To set up and configure dotLINK as a new Terminal Server acquisition port follow this procedure 1 Select Add Acquisition Port from the Ports menu to open the Add Acquisition Port dialog box Initially only the Device Type list is shown 2 Select Terminal Server from the Device Type list After you select Terminal Server the appropriate entry controls for that device are displayed The following briefly describes each of the entry controls by device type 3 Enter the following information in the Network name field e DHCP Enter the Device name of the dotLINK the name by which the device is known to your network assigned as described above in the Network name text box If the name is valid the dotLINK s IP address is displayed If the name is not valid a warning message appears but you can continue However communication with the Chapter 2 Installation Configuring TotalChrom Acquisition Ports to use dotLINK dotLINK cannot be established until the valid IP address for it is determined e Static Enter the IP address of the dotLINK in the Network name text box It will be copied to the IP Address field 4 Enter 3001 as the port number in the Port Number s text box Add Acquisition Port x Device type Terminal Serer
13. TE When dotLINK is connected to TotalChrom it displays dotLINK as Interface Type 610 EPROM 4 x 24 Chapter 3 Updating dotLINK NOTE dotLINK Must Be Connected and Configured to TotalChrom 1 Refer to Chapter 2 in this manual if necessary 2 In the TotalChrom Navigator choose Instrument Configuration from the Build menu The Configuration Editor opens 3 Highlight the dotLINK that you wish to get the version from The version will appear in the lower left corner of the Configuration Editor window 2 Configuration Editor File Instrument Interface User View Help srl m B Blerta ee al Name Location Type Acq Port Acq Server LINK Port WhatE verlnst Any Lab AUTSYSH Clarus Peter 3001 zzshismithda40 A 69 2 101 a40 Anylnst LC2008 169 254 6 i hda40 Interface Instrument Configuration Type Instrument Type Binary LC Pump Model 2008 250 Eprom 4 Autosampler Type 155200 Memory Data Source Diode Array Detector Serial number Options NONE Ch A Count Voltage Threshold Ch B Count Fan Temperature A S Syringe Volume A S Seat Capillary Vol Instruments list Operation 25 Updating dotLINK Updating dotLINK Software To update the dotLINK software follow this procedure 1 Unplug the dotLINK power cord from the back of the dotLINK If you have an Integral dotLINK turn OFF the PerkinElmer Clarus GC 2 Plug the Type 10 USB key with WinCE compatible drivers containing the up
14. an available DHCP Address or assign a Static IP address including a Network Mask address The IcarusIPConfigure application can also be used to assign a Device Name to the dotLINK Install the Applications on the Host Computer The dotLINK Utilities and User Manual CD P N N515 2015 contains applications and the dotLINK User s Guide in Adobe Acrobat PDF format Copy the User s Manual to a directory on your hard drive Then run Setup on the CD to copy the IcarusIPConfigure application to your host computer s hard drive About Using DHCP DHCP may be used when the dotLINK is on a network which has a DHCP server This permits you to automatically obtain an IP address and subnet mask Contact your network administrator to determine if DHCP is available and the preferred way to operate dotLINK Chapter 2 Setting Up dotLINK for Ethernet How to Configure dotLINK DHCP NOTE The MAC Address IP Address and Network Mask shown below are examples only 1 Connect the host computer to the source network subnet as the dotLINK 2 Locate the directory on your computer s hard drive where you copied the files from the dotLINK CD 3 Double Click the IcarusIPConfigure exe application The IcarusIPConfigure dialog appears z IcarusiPConfigure MAC Address eo se foo jo foo Get IP config Status Configuration IP Address C Static IP I fi C DHCP Set IP config Network Mask g Gateway Device Name 4 E
15. citive loads are frequently switched e currents and associated magnetic fields are high These are the major contributors to the industrial electromagnetic environment and as such distinguish the industrial from other environments The dotLINK standalone is not intended for connection to a public mains network supplying residential commercial and light industrial locations Information and Symbols Appearing on the Standalone dotLINK Power Supply AC voltage symbol SSA DC voltage symbol Indoor Dry Location Use Only ge No Serviceable Parts Inside Q Refer to Instructions N dotLINK Box DC voltage symbol re Do not put in trash WEEE Directive E 4 Chapter 2 Safety and Site Data for dotLINK Standalone The symbol above indicates that Waste Electrical and Electronic Equipment WEEE is not to be disposed of as unsorted municipal waste Equipment marked with this symbol is to be collected separately The objectives of this program are to preserve protect and improve the quality of the environment protect human health and utilize natural resources prudently and rationally Specific treatment of WEEE is indispensable in order to avoid the dispersion of pollutants into the recycled material or waste stream Such treatment is the most effective means of protecting the customer s environment The waste collection reuse recycling and recovery programs available to PerkinElmer s customers vary by customer location Please contact
16. d IPM Could be result of bug in dotLINK OS EPROM 2 File does not exist A Task tried to access a non existent file Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM 3 PCB is already open A Task tried to open a Pipe Control Block that was already being used Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM 4 File is already open A Task tried to open a file that was already open Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM 5 File is protected read only A Task tried to write to a file that is read only Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM 6 PCB has no open file No file was open A Task tried to read from or write to a file that had not been opened yet Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM 33 dotLINK Error Messages 7 10 11 12 34 File not open for write A Task tried to write to a file that had not been opened yet Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM File not open for read A Task tried to write to a file that had not been opened yet Probably result of bug in IPM Could be result
17. dated dotLINK software into the S W UPDATE USB port on the back of the dotLINK or on the side panel of the PerkinElmer Clarus GC containing an Integral dotLINK 3 With the Updated USB key plugged into the dotLINK plug the power cord back into the dotLINK If you have an Integral dotLINK turn ON the PerkinElmer Clarus GC Back View 4 With the USB key still plugged into the dotLINK and the dotLINK powered on the update will now proceed automatically Anytime within 90 seconds the LED s on the front of the dotLINK will begin to blink as the update is being downloaded The LEDs will remain blinking as long as the update is downloading The download could take several minutes gt Data Handling PerkinElmer System LINK s gt 00 gt 5 When the LED lights on the front of dotLINK stop flashing this could take several minutes all the update files have been transferred 26 Chapter 3 Updating dotLINK Verifying the Software Update To verify that the dotLINK software has been successfully updated follow this procedure 1 With the Configuration Editor still displayed choose the dotLINK that you just updated 2 Choose Configure from the Instrument menu 3 Click the plus sign to expand the display to show the ports and select the data acquisition port to which the dotLINK is connected 4 When the port is highlighted click the Query Port For Type button T
18. e port re add it and substitute the new information See Deleting an Acquisition Port for information 22 Chapter 2 Chapter 3 Operation The operation of the dotLINK Interface is directed via the TotalChrom software executing on the host computer The manuals associated with the TotalChrom software provide detailed instructions on configuring and operating the dotLINK interface The status of the dotLINK Interface is monitored through the use of the TotalChrom software Each standalone dotLINK provides a simple indication of its status using a set of LEDs located on the front panel the Integral dotLINK only has one LED During routine operation these LEDs provide an indication of the activity on each Instrument Port as described in Status LEDs below gt Hand A B C RR Lane Se LINK O O O 383 Status LEDs After the completion of the Self Test when communication between the host computer and the dotLINK Interface occurs the LEDs will blink Each LED shows the status of a Serial port There is a total of six LEDs in the standalone version and one LED in the Integral dotLINK version Green represents no errors or problems IPM loaded Blinking Green transmitting data on that serial port no error Yellow represents programming algorithms active configuring firmware for upgrading or downgrading Blinking Yellow transmitting data on that serial port with error Resetting dotLINK NOTE T
19. eeeenaeceeeeeenaeens 10 Serial Connection to the Computer ee eee ese ceecseecneeeeeeeeeeeceseeeeeeseeeeseeeenseeseeaeenaes 11 Ethernet Connection No Lab Network 0 cee eescecsseceesceceseceeececeseeeeneeceeeeeeneeceeeesnaeeenees 12 Ethernet Connection to Lab Network cccesccesscecsseceesceceseeeeaeeceseeeeneeceaeeeeaeceeneeenaeeenees 12 Setting Up dotEINK for Ethernet temi ea 12 Install the Applications on the Host Computer uunsessessnesnnesnnesnnesnnennonnennnennennon nenn 12 About Using O AA 282 sea Dis inne 12 How to Configure dotLINK DHCP 00 0 cece eesceseeeeseceereeeeeceeneeenaeceeeeenaeceeeeeenaeens 13 About Using Statie IP enges ss an 15 How to Configure dotLINK Static IP oo cee eesseeseceesceceseeeenceceecesaeceeeeeeaaeceeeeeeneeees 15 How to Set Your Computer to Static IP 222u22402200nsenseennnnnnnsnnsnnesnnesnnennnennonsen nenn 18 Configuring TotalChrom Acquisition Ports to use dotLINK uessesseesnesnnesnnesnnennne nen 20 Adding a New Acquisition Pott unseesseesessserssnsnnesnesnnesnnennnennnennonnnensnennnennennnnnnennnennn 20 Ports Tab Display nennen nes 22 Chapter 3 Operation Status LEDS tia E lied titan discado 23 Resettine dotLINK ia a esse Meinl oa oido 24 NI ONO 24 Resettins an IP Address een aa a aa Er a ae a REE EEEE E 24 Brook rutaaa Loia D AN CEE sete sacs ee TE 24 Checking the Software Versiones eine r nona aaneen sa I anea 2
20. een compromised or bypassed Make sure that nothing has been added to the Interface other than the approved connections 31 Troubleshooting Guide e A second possibility is that some component is intermittently failing for reasons other than ESD degradation Use the Interface only when its operation can be isolated and observed If the problem is caused by a component failure it should quickly become reproducible 5 Power is ON But Self Test Not Executed standalone dotLINK only Reinstall the dotLINK software using a USB update key Return the Interface for service as described in Warranty Service 6 IcarusIPConfigure returns No Reply Received DotLINK must be on the same subnet as the PC running the IcarusIPConfigure process Try connecting a crossover Ethernet cable between dotLINK and the PC some older PCs may require an Ethernet crossover cable if dotLINK is connected directly to the PC 32 Chapter 4 dotLINK Error Messages dotLINK Error Messages Technical Data The following errors may be reported by the host software Following each error is a description of potential problems that may result in the error message Additional IPM specific errors are documented in the various IPM Installation Manuals 0 No error occurred ERROR command was given and no error had occurred 1 File already exists A Task tried to create a file but it already exists Probably result of bug in IPM Could be result of corrupte
21. er supplies Functional Description Microprocessor SH4 7760 highly integrated 32 bit processor This microprocessor has on chip peripherals ranging from serial ports to USB to an LCD controller Permanent Storage The processor board has 32MB of flash in which to store the Boot loader OS and application Temporary Storage There is 32MB of SDRAM on the card engine Ethernet Ethernet is provided by an SMSC 91C111 non PCI Ethernet MAC and PHY This provides one port of switchable 10 100 Base T Ethernet Serial There are three serial ports that are integral to the processor 30 Chapter 4 Troubleshooting Guide Troubleshooting Guide Technical Data If the dotLINK Interface is not operating correctly power cycle it by unplugging the standalone dotLINK from the power then plug it back in or if you have Integral dotLINK use the GC power switch Wait a few seconds then switch the Power ON again If one or more of the following symptoms occur perform the described action 1 Failure to Communicate With Host Computer RS 232 Serial Communications RS 232 communication to the host computer is generally accomplished through a direct connection to the PC com port or Ethernet port or through a terminal server attached to a network thereby introducing several points for potential communication problems A typical problem is inconsistencies in the configuration information that is provided to the terminal server to the ser
22. ess is used when the dotLINK is connected directly to the host computer or if it is connected through a hub or switch It may also be used if your network administrator provides a valid static IP address and subnet mask How to Configure dotLINK Static IP on a Network You will configure the dotLINK with a Static IP address This is done by clicking the Static IP radio button and entering the desired Static IP Address into the IP Address edit field and the Network Mask for the Static IP address that you are using into the Network Mask edit field NOTE MAC Address IP Address and Network Mask shown below are examples only 1 Setup installed the IcarusIPConfigure exe application in the C Program Files PerkinElmer dotLINK directory 2 Double click IcarusIPConfigure exe or from Start gt All Programs click Configure dotLINK The IcarusIPConfigure dialog appears z IcarusiPConfigure MAC Address Get IP config Status Configuration IP Address C Static IP C DHCP Set IP config Network Mask Gateway Device Name 3 Enter the MAC Address of the dotLINK that you wish to configure into the MAC Address edit field This number is printed on a label on the dotLINK 4 Click the Get IP config button located next to the MAC Address edit field Installation 15 Setting Up dotLINK for Ethernet fc IcarusiPConfigure MACAddess fill eo se foo foo foo Status Configuration 3
23. g on the host computer to specify the instrument operating parameters dotLINK then receives instructions from the host computer and formats and transmits commands to the connected instrument Data and status information are received from the instrument by dotLINK formatted as Introduction necessary and transmitted to the host If the host or intervening network is unavailable the dotLINK Interface will buffer the information until it can be transmitted Instructions from the host to dotLINK can be sent as methods or setpoints Methods include an entire set of parameters sufficient to initiate and execute an analysis on an instrument Setpoints are used to modify a single parameter during an analysis dotLINK is capable of storing multiple methods for each connected instrument allowing sequences of multiple methods to be executed even when the host computer is not available The exact set of method parameters that can be controlled for a given instrument are dependent on the characteristics of that instrument These parameters are described in the documentation that accompanies the IPM distribution media for the specific instrument Instrument Personality Modules are stored in non volatile memory in the dotLINK Interface Re configuration is not required after cycling power on the Interface However buffered data will be lost if power is interrupted as will method and sequence information stored in dotLINK for later analyses The amoun
24. he F LED will light green when dotLINK is on and blink to show CPU activity Resetting dotLINK Before reusing dotLINK with another IP address or a new instrument configuration reset dotLINK as follows Removing IPMs 1 Using a non metallic stylus press and hold the Reset button in for 10 sec and release it Power cycle the dotLINK by unplugging the power cord from the dotLINK and then plugging the power cord back into the dotLINK If you have an Integral dotLINK power cycle the PerkinElmer Clarus GC by turning it OFF then ON Resetting an IP Address 1 Using a non metallic stylus press and hold the Reset button on the back of the dotLINK While holding the Reset button power cycle the dotLINK by unplugging the power cord from the dotLINK and then plugging the power cord back into the dotLINK If you have an Integral dotLINK power cycle the PerkinElmer Clarus GC by turning it OFF then ON Updating dotLINK NOTE Only use a Type 10 USB key with WinCE compatible drivers to update dotLINK If you have questions about the USB key contact PerkinElmer Updating dotLINK is performed using a USB key via the USB port on the back of the dotLINK This Update capability enables you to change the version of the dotLINK firmware to either a new version or a previous version of the dotLINK software Checking the Software Version Before updating the dotLINK check and note the software version on the dotLINK box NO
25. he cable to the appropriate port on the dotLINK When using a PerkinElmer Clarus GC with an Integral dotLINK all instrument connections are already made internally The instrument will be connected to either a local area network or to a local host PC using the appropriate cable connected to the serial or Ethernet port on the side panel of the GC Chapter 2 Installation Installing the dotLINK Hardware 10 Cable 09290144 Agilent GC or LC dotLINK 25 Cable 09290145 10 Cable 09290146 PerkinElmer Clarus GC dotLINK 25 Cable 09290147 5 Cable 09290148 PerkinElmer LC Pump 5 Cables 09290149 PerkinElmer Autosampler PerkinElmer Detector Serial Connection to the Computer Computer dotLINK Supplied Cable 0929 0144 F port Com Port RJ45 to D shell 11 Setting Up dotLINK for Ethernet Ethernet Connection No Lab Network Computer dotLINK Supplied Cable 09991463 Ethernet Ethernet RJ45 to RJ45 Ethernet Connection to Lab Network dotLINK Supplied Cable 09991463 Fthernet RJ45 to RJ45 To Lab Network Setting Up dotLINK for Ethernet 12 This describes how to set up dotLINK for an Ethernet connection to a local host computer or to a local area network The dotLINK uses an application called IcarusIPConfigure to perform the task of assigning an IP Address The IcarusIPConfigure application using the dotLINK s MAC Address can search for
26. he status of a Serial port The A D LEDs work as LEDs follows ARE 1 Green represents no errors or problems IPM loaded i P 000 2 Blinking Green transmitting data on that serial port no error D F 3 Yellow represents programming algorithms active configuring firmware for upgrading or downgrading 4 Blinking Yellow transmitting data on that serial port with error LED E is reserved for future use LED F indicates the CPU status Blinking Green indicates normal CPU activity LED Off indicates the CPU is busy Installation Back Panel Standalone Back Panel Standalone gt I A B t PerkinElmer o Shetlon CT ocana USA os EN SEO1 C asr A Group 1 M o S M UPDATE Integral dotLINK PerkinElmer Clarus GC Right Side Panel RESET F ETHER NET Chapter 2 Integral dotLINK PerkinElmer Clarus GC Right Side Panel Reset Button 2 RESET The reset button is a recessed momentary contact style located on the back of the box You will need to use a non metallic stylus to fully depress the button Clear IPMs While the dotLINK is running you can clear the IPMs loaded in the dotLINK by pushing the reset button Clear IP Address Hold down the reset button while plugging the power cable into dotLINK In the event that you need to clear the dotLINK IP address for example if a dotLINK has to be moved from one lab to a
27. he version is displayed in the Interface type box on this dialog 5 After verifying that dotLINK has been updated click the cancel button Operation 27 Chapter 4 Technical Data Functional Description The descriptions in this section are not intended to be a technical definition of the dotLINK interface Rather they are provided for those situations in which a better understanding of the interface may aid in its application The dotLINK is a dedicated processor system acting as an instrument interface It will contain a processor board Ethernet interface RS 232 interfaces a USB interface on board voltage regulators reset button and external LED indicators dotLINK Personality board The dotLINK personality board carries the electronics necessary for the operation of the dotLINK This allows the processor board to function as it supplies necessary connections and power The Ethernet chip is the SMSC 91C111 is anon PCI Ethernet Mac and PHY Connections The dotLINK personality card has 6 serial ports 1 Ethernet port and 1 USB port Both the Serial ports and Ethernet ports use an RJ 45 connector The USB connector is a standard A type USB connector The processor board is connected to the dotLINK personality board by using a fine pitch board to board connector Electronics The dotLINK personality board has all necessary electronics including Ethernet MAC and PHY Ethernet Magnetics 6 UARTS RS 232 drivers and pow
28. ht 2005 PerkinElmer Inc Produced in the U S A Trademarks Registered names trademarks etc used in this document even when not specifically marked as such are protected by law PerkinElmer is a registered trademark of PerkinElmer Inc Table of Contents Table of Contents icici ra a nn i Chapter 1 Introduction Chapter 2 Installation Safety and Site Data for dotLINK Standalone u22224022402sensoennennnnsnnesnnesnnesnnennnennen nn 3 FCC Compliance United States and Canada ooooooccnoccnonononoccconanonnnccnnnncnn cnc nononnccnnnoncnnccnnno 3 EMC Directive European Union essor iinne ie ii e 4 Information and Symbols Appearing on the Standalone dotLINK 4 POC Compl anne ansehen REE EES aS EEES REENE SEERE TSRS 5 EMG information i 5 Power Supply module u r2eeegeess se gesessen ns 5 Cleaning the dotLINK Standalone u2uusssuessesnnesnnesnnennesnnesnnesnnennnesnnn nennen 5 Power Connections u eisernen cionado 6 Available Power Eords u nennen tes essen ansonsten 6 Cables orein ern tr 7 o SAA AS 7 Back Panel Standalone AAA TN 8 Integral dotLINK PerkinElmer Clarus GC Right Side Panel 202 200220022 8 Installing the dotLINK Hardware 00 cece eecesecesecsseceecesecnsecseecseecaeeeaeseaeeeeeeseeeeeessseseenseenaes 10 Cable Connections to Your Instrument cceeeeesseceseeesceceneeeeseeceseeenaeces
29. k when done with them Probably result of bug in IPM 37 dotLINK Error Messages 38 53 54 60 61 62 63 64 65 66 Ran out of Chores This is probably the result of a task that asks for chores from the dotLINK Operating System but neglects to give them back when done with them Probably result of bug in IPM Extra Acknowledgement was received Results when dotLINK receives a packet protocol acknowledgement it was not expecting Probably result of bug in Host software Communications error Probably result of incorrect Baud rate Could be result of noise on RS 232 line Instrument reports an error Probably result of a problem at the instrument Could be result of an improper configuration The instrument that dotLINK is controlling has reported an error The error message is instrument specific Refer to the IPM Installation Manual for further details IPM was already installed An INSTALL command was issued when an IPM had already been installed at that port Probably result of bug in Host software Parameter cannot be changed in this mode This error typically occurs when the host system attempts to send a non setpoint parameter while the chromatograph is in the midst of a run This is a read only parameter This error typically occurs when the host system attempts to change a parameter that cannot be edited dotLINK has not taken control of the instrument yet Many instrument c
30. nother you have to force dotLINK to not have an IP address so that it will not affect the operation of the customer s network bV 0e The connection from the power supply to the dotLINK box is the same regardless of country and it is a standard low voltage connection to the box The country cable plugs into an industry standard connection on the power supply which is external to the dotLINK box The connectors for Serial ports are RJ 45 connectors dotLINK has six serial ports Four of these serial ports ports A D are used for connections to instruments Port E is reserved for future use Port F can be used to connect the dotLINK to the host computer 8 W UPDATE The Universal Serial Bus USB port is used for software updates The update will be provided by PerkinElmer The port is a standard USB 1 1 style A host type connectors Simply plug a USB Type 10 flash key using WinCE compatible drivers into the USB S W UPDATE port and the dotLINK software will download the update and handle switching over to the new code Installation Installing the dotLINK Hardware The Ethernet port supports 10Base T and 100Base T ETHERNET transfer rates The Ethernet port uses an RJ 45 connector The Ethernet connection will be via an automatic speed sensing Ethernet device that is capable of transporting data at either 10Mbps or 100Mbps In some installations an inst
31. nter the MAC Address of the dotLINK that you wish to configure into the MAC Address edit field This number is printed on a tag on the dotLINK 5 Click the Get IP config button located next to the MAC Address edit field fc IcarusiPConfigure MAC Address Status Configuration 3 C Static IP IP Address C DHCP Set IP config Network Mask Gateway Device Name Installation 13 Setting Up dotLINK for Ethernet 14 When a DHCP Address is found the IP Address and Network Mask edit fields will be populated and the Status will read Received Reply The Configuration section fills in the following IP Address Network Mask Device Name and selects either Static IP or DHCP z IcarusiPConfigure MAC Address 00 Get IP config Status A eceived reply Configuration IP Address Static IP di Set IP config DHCP Network Mask Gateway Device Name Lab 4 If Status comes back No reply received click the Get IP Config button until Status reads Received Reply If this does not happen see Troubleshooting If Static IP is selected change it to DHCP Enter a Device Name unique to the network and click the Set IP config button Write down the Device Name since you will need it to configure TotalChrom The dotLINK has now been configured for a DHCP IP address Chapter 2 Setting Up dotLINK for Ethernet About Using Static IP Static IP addr
32. o 35 C operating 5 to 40 C safe operating 20 to 60 C storage non operating Altitude 0 to 2 000 meters operating 0 to 12 000 meters non operating Relative Humidity 20 to 80 non condensing Pollution Degree The dotLINK will operate safely in environments that contain nonconductive foreign matter up to Pollution Degree 2 in EN IEC 61010 1 40 Chapter 4 acquisition ports adding 20 Back Panel Connections 8 cables 7 clear IP address 9 clear IPMs 9 computer setting to Static IP 18 DHCP configuring 13 using 12 EMC Directive 4 EMC Information 5 Error All LEDs blinking rapidly 31 All LEDs remain ON 31 LEDs continue to blink after self test 31 LINK Error Messages 33 No front panel LEDs ON 31 Error Messages 33 Ethernet port 10 Failure to Communicate With Host Computer 31 FCC Compliance 5 FCC Notice 3 Front Panel Connections 7 Functional Description 29 Index Installation cables 3 Instrument Cable connections 10 LEDs 23 MAC Address 15 Operation 23 ports adding 20 power connections 6 power supply 5 reset button 9 Safety and Site Data 3 serial ports 9 Service 39 set up dotLINK 12 setpoints 2 Specifications 39 Static IP configuring 15 using 15 Status LEDs 23 symbols 4 Troubleshooting Guide 31 USB port 9 Warranty Service 39 WEEE Directive 5 41 WEEE Instructions for PerkinElmer Products or A label with a crossed out wheeled
33. of the WEEE Directive Please contact these producers directly before discarding any of their products Consult the PerkinElmer web site http www perkinelmer com for producer names and web addresses
34. ommands require that the instrument be seized This error results if SEIZE command was not issued first Probably result of bug in Host software Could be result of someone releasing control of instrument with dotLINK TALK and then restarting the Host software Autosampler not installed Probably result of improper configuration Chapter 4 Warranty Service 67 Data segment has not been released with OC command Probably result of bug in Host software 99 The subroutine that was called is not finished yet Probably result of bug in IPM 255 Fatal system error This error will result on recovery from a Fatal System Error A Fatal System Error is signified by all of the LEDs blinking Follow the Reset Procedure to have dotLINK recover reset itself Afterwards an error 255 will be obtained Please write down the register values reported with this error so factory engineers can trace the cause of the malfunction Warranty Service If repair is required please contact your local PerkinElmer service office Specifications Dimensions dotLINK Box 8 0L x 4 0W x 2 0H in 203 2 L x 101 6 W x 50 8 H mm Power Supply 3 3L x 18Wx1 3H in 85 0L x 46 0W x 33 0H mm Mass Weight dotLINK Box 0 652 kg 23 oz Power Supply 0 136 kg 4 8 oz Power Supply Input 100 240 VAC 10 50 60 Hz 1 0 3 A max current Output 5 VDC 2 A maximum Technical Data 39 Specifications Temperature Indoor use only 10 t
35. ork you will need to set the host computer to a static IP address The following procedure describes how to set a static IP address in Windows XP To set your computer to a static IP address follow this procedure 1 2 18 Open Control Panel from the Windows Start button Double click on Network Connections Right click on Local Area Connection and select Properties In the General tab select Internet Protocol TCP IP the click the Properties button In the General tab click Use the following IP address and type the static IP address 192 168 1 1 and Subnet mask 255 255 255 0 as shown below Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 1 Subnet mask B55 255 EN Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server Chapter 2 Installation Setting Up dotLINK for Ethernet 6 Click OK to close each dialog box 7 Open IcarusIPConfig and set the following e IP Address 192 168 1 2 NOTE Use a different IP Address for each additional dotLINK e Subnet mask 255 255 255 0 de IcarusiPConfigure MAC Address 00 60 se foo foo foo Get IP config S
36. rument system may require connection to one or more Instrument Ports for example a gas chromatographic system may require one connection to the chromatograph and one connection to the autosampler In cases where multiple connections are required for a single system adjacent ports must be used Detailed connection requirements are provided in the instructions that accompany each Instrument Personality Module distribution package The communication characteristics baud rate parity handshaking etc of each Instrument Port are controlled by the IPM installed for that port Cables should be purchased for each instrument with the IPM package Installing the dotLINK Hardware 10 After removing dotLINK from its box connect it to your instrument and then connect it to a computer using one of the following three configurations Cable Connection to Your Instrument Serial Connection to the Computer Ethernet Connection No Lab Network Ethernet Connection to a Lab Network Cable Connections to Your Instrument Depending on the type of instrument being used dotLINK communicates to the instrument using one or more serial ports The ports are on the dotLINK back panel or in the case of a PerkinElmer Clarus GC on the right side panel of the GC The cables are specific to each instrument and should be purchased with the Interface Connect the cable by inserting one end into the instrument or module connector and attach the other end of t
37. t of data that can be buffered by a dotLINK is dependent on several factors including the instrument s connected to the dotLINK Interface and the number of methods stored in the dotLINK Interface As an example a dotLINK or Integral dotLINK connected to a single PerkinElmer GC with a single stored method has buffer for approximately 195 000 data points Each stored method reduces the buffer capacity by approximately 500 data points Additionally connecting a Hewlett Packard 5890A GC reduces the buffer capacity by approximately 2500 data points 2 Chapter 1 Chapter 2 Installation The dotLINK Interface is designed for easy customer installation It uses a serial connection through an RJ45 port to a connector for your specific instrument There are NO internal settings or adjustments for you to change The installation procedure requires three steps 1 Install dotLINK hardware 2 Configure dotLINK 3 Configuring TotalChrom Acquisition Ports to use dotLINK Details on each of these steps are provided in the following sections Safety and Site Data for dotLINK Standalone NOTE dotLINK contains no user serviceable parts Therefore there is no reason to remove the cover panels in normal usage If you need to remove any cover panels first disconnect the power cord from the AC mains outlet FCC Compliance United States and Canada This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
38. talled The operation of these various models is otherwise identical from the user perspective only the cabling is different Data acquired from each instrument are buffered within dotLINK until the data can be transmitted to the host computer The dotLINK device provides both instrument control capabilities as well as digital data acquisition for supported chromatographic instruments and modules There will be no data processing occurring within the dotLINK itself other than that required for secure data communications between the instrument and the TotalChrom Acquisition Server This data communication will be controlled through a combination of the dotLINK O S running in emulation mode and standard functionality of the Windows CE operating system and CPU Data will be secure because there will be no user access allowed There is no user interface for dotLINK all user interaction is with the software running on the host computer Internal to dotLINK is a microprocessor that executes firmware located in an Instrument Personality Module IPM The IPM is copied to the dotLINK from the host computer by a Configuration Utility executed on the host computer During execution of the Configuration Utility you will provide information regarding the type of instrument connected to each port allowing the host software to select one or more IPMs to be down loaded Once an IPM is installed in the dotLINK you can interact with the PerkinElmer software runnin
39. tatus Configuration IP Address i Static IP ESTA R PE et IP config Network Mask Gateway Device Name 8 Then click the Set IP config button 19 Configuring TotalChrom Acquisition Ports to use dotLINK Configuring TotalChrom Acquisition Ports to use dotLINK 20 In order to use a server computer to acquire chromatographic data you must associate that server computer with one or more data connections referred to as acquisition ports An acquisition port is a communication port through which chromatographic data are acquired from a dotLINK or other device such as terminal server or PerkinElmer s NCI interface Adding a New Acquisition Port NOTE For Client Server only Before you can add an acquisition port you must configure the desired acquisition server computer as a valid TotalChrom server for more information see Configuring Servers in the TotalChrom Application Manager s Guide In order to use a dotLINK in TotalChrom it must either be connected to a serial port or configured in TotalChrom using the terminal server selection To configure a dotLINK In TotalChrom using the terminal server selection you must know dotLINK s network name DHCP or Static IP address and you must use 3001 as the four digit port number of the specific dotLINK terminal server port you want to use dotLINK in not a terminal server even though it is using the terminal server selection in TotalChrom
40. the responsible body e g your laboratory manager for information about local requirements FCC Compliance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation EMC information EN 55011 Class A Group 1 Power supply module The only power supply module authorized for use with dotLINK is supplied by PerkinElmer Cleaning the dotLINK Standalone CAUTION Do not clean the power supply module Exterior surfaces of the dotLINK box may be cleaned with a soft cloth dampened with a mild detergent and water solution Do not use abrasive cleaners or solvents Before using any cleaning method except that specified above users should check with PerkinElmer that the proposed method will not damage the equipment CAUTION The protection provided by the dotLINK standalone may be impaired if the product is used in a manner not specified by PerkinElmer The dotLINK standalone requires no specified inspection or preventive maintenance to ensure the continuous functioning of its safety features Installation 5 Safety and Site Data for dotLINK Standalone Power Connections This section applies to standalone dotLINK Interfaces only The dotLINK Interface is a safety Class I apparatus and uses a three conductor line cord
41. uld be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Ran out of Pipe Control Blocks This is probably the result of a task which requests Pipe Control Blocks from System but fails to return them when done May require that the rogue task execute several times before error occurs Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Pipe Control Block not assigned to Task yet Probably result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM Illegal filename Illegal characters were given in a filename Probably result of bug in Host control program Could be result of bug in IPM Could be result of corrupted IPM Could be result of bug in dotLINK OS EPROM File is erased This is a DEVICE not a file An operation was attempted on a device that only applies to a file File is too large This error results if you try to download an IPM that is larger than 16K bytes Probably result of bug in Host control program Could be result of a corrupted IPM file at Host computer BIN failed verification during write operation When you download an IPM dotLINK always verifies that it got written correctly If verification fails then this error would result Probably result of missing SRAM chip s 35 dotLINK Error Messages 36 22 23 24 25 26 27 28 29 30 Could be result of
42. ver software on the host computer and to the host application e g SYSCONFIG for TotalChrom C S Inconsistencies in this data can result in an Interface that does not respond Problems can also arise from unexpected sources such as an inappropriate request for a port connection from an application running on another network node If you are using a Terminal Server disconnect the dotLINK from it and connect the dotLINK directly to the COM port or Ethernet port of the PC Newer PCs can handle this connection with a regular cable If you have an older PC you may need to connect a crossover cable between the PC and the dotLINK 2 No Front Panel LEDs On standalone dotLINK or No GC Side Panel LEDs On Integral dotLINK a Check the power cord for proper connection to an operative power receptacle b Try to configure the instrument the LED may light when the configuration is complete 3 LEDs Continue to Blink After Self Test standalone dotLINK only This indicates an error occurred during the self test Reinstall the dotLINK software using the USB update key 4 All LEDs Blinking Rapidly or All LEDs Remain ON standalone dotLINK only If the problem recurs after cycling power contact the Service Department as described in Warranty Service If the problem does recur there are two possible explanations e The dotLINK Interface has extensive shielding against electrostatic discharge ESD the integrity of which may have b
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 保証書付 Florida Pneumatic FP-706K Use and Care Manual Manual de Instalación 2012 APA Exhibitor Service Manual Philips 8000 series 40PFL8008K 40" Full HD 3D compatibility Smart TV Wi-Fi Black User Manual - Hazardous Materials Storage Dual CS 455-1M audio turntable ラリーアート P.1(フォーム) GSM / GPRS MODEM GSM20 Copyright © All rights reserved.