1. The button to activate a fire alarm The place to apply a seal FS Se 2 3 LED Indication Table 1 describes indication of the operation modes of the call point Figure 2 Table 1 LED Behavior Condition Event Flashing once per 8 seconds Norm Double flashing once per 8 seconds Fire Alarm Triple flashing once per 8 seconds Tamper Alarm or Trouble Triple flashing blinking once per 2 seconds In an addressable alarm loop non programmed factory address is indicated Connecting to a non addressable alarm loop or dc voltage Four time flashing once per second a oa Waiting for assigning an address 2 4 Programming a Call Point Address For operation the call point has to be assigned to an address in the range of 1 to 10 The call point is delivered with no address If a call point with non assigned address is wired into an addressable alarm loop the LED indicator blinks once per two seconds Assigning an Address Connect the call point with its cover removed into a disarmed alarm loop of the Type 1 of the Signal 10 panel or to a 10 V to 12 V power supply In 6 s four time flashing of the LED once per second means that the call point is ready to receive an address Press the tamper switch and hold until the LED is lit steady then release the tamper switch Press the tamper switch again so many times as the relevant address
2. to 93 at 40 C Wall Plug 8x30 2 pcs 7 Transportation and Storage Temperatures Minus 50 C to 55 C Package pe 8 Overall Dimensions 95 mm x 91 mm x 33 mm 9 Weight 0 15 kg max For a group delivery 10 Average Lifetime 10 years min IPR 513 3PAM Manual Call Point 10 pes Instruction Manual pe Special Key 10 pcs Woodscrew 20 pcs Wall Plug 8x30 20 pcs Package 10 pcs Group package pe 2 OPERATION INSTRUCTIONS 2 1 Wiring Figure 1 shows a typical schematic for wiring the call point Signat 10 10k Figure 2 shows the view of the call point without the protective flip cover T B If the call point has been open a Tamper Alarm message is generated but a Fire Alarm l message cannot be sent 2 2 Mounting The call point is to be mounted using the two screws provided to a flat vertical surface in accordance with your applicable local standards codes regulations and ordinances The wires which pass under the call point should not be clamped by the call point case Figure 2 shows the view of the call point without the protective flip cover The hole to insert the key to reset the activated call point The holes to insert the key to open the call point case The special key to reset the activated call point and to open its case The tamper switch of the call point
3. ADDRESSABLE RESETTABLE MANUAL CALL POINT IPR 513 3PAM x HCO 9001 TP INSTRUCTION MANUAL 1 TECHNICAL DATA 1 1 General IPR 513 3PAM Addressable Resettable Manual Call Point hereinafter referred to as the call point or the IPR 513 3PAM is to be used in fire alarm and fire extinguishing systems in order to trigger a fire alarm manually or to initiate a fire suppression system The call point is to operate under control of a Signal 10 panel in one of its Fire Threshold Addressable Alarm Loops Type 14 Up to ten call points with individual addresses 1 to 10 can be connected to a single alarm loop of the Type 14 each call point being capable of sending the following messages to the panel Fire Alarm Norm and Trouble To have more information about operating the call point in the addressable mode please refer to the Signal 10 User s Manual The protective transparent flip cover of the call point can be sealed The firmware version of the call point is v 1 00 The call point is intended for round the clock operation 1 2 Specifications 1 3 Standard Delivery 1 Alarm Loop Voltage 27 V max For an individual delivery 2 Consumed Current 300 uA max IPR 513 3PAM Manual Call Point pc 3 Pre operation Time 20 s max Instruction Manual pe 4 Ingress Protection Rating IP41 Special Key pe 5 Operating Temperatures Minus 30 C to 55 C Woodscrew 2 pcs 6 Relative Humidity Up
4. is one to ten times In 5 s the LED shall flash the number of times equal to the assigned address and light for a half of a second Auto Assigning to a First Vacant Address of a Loop Connect the call point with its cover removed into an addressable alarm loop of the Signal 10 In 20 s press on the button which activates fire alarms In about 6 s the LED switches on for 1 s and then switches off The address has been assigned Requesting for the Address Connect the call point with its cover removed into a disarmed alarm loop of the Type 1 of the Signal 10 panel or to a 10 V to 12 V power supply In 6 s four time flashing of the LED once per second means that the call point is ready to receive an address Press the tamper switch and hold until the LED is lit steady then release the tamper switch In 5 s the LED shall flash the number of times equal to the assigned address and light for a half of a second 2 5 Routine Testing 2 5 1 Before testing the call point please disconnect executive outputs of all system devices and modules that can release an extinguishing agent or activate light and sound alarms Notify the proper authorities that the system is undergoing maintenance 2 5 2 Arm the alarm loop of the Signal 10 with the connected call point the last one being indicating its Norm status by flasing once per 8 s 2 5 3 Activate the call point by pressing the key The Signal 10 shall indicate the fire alarm for the given address the call point LED do
5. uble flashing every 8 s 2 5 4 Reset the call point to its Norm state by inserting the special key provided Ensure the call point LED starts flashing once per 8 s From the console or PC issue a command to cancel the alarm from the call point If the Fire Alarm message is not received by the console or PC the call point is unhealthy and must be replaced 2 5 5 Repeat steps 2 5 2 2 5 4 mimimum three times 2 5 6 After testing verify that the call point is ready to operate properly Then restore operability of all the system components disconnected before testing and notify the proper authorities that the system is back in operation 2 5 7 Test the call point operability at least once per three months All the equipment used in testing must be known functioning O T D ZAO NVP Bolid 4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 775 7155 Email info bolid ru Technical Support support bolid ru http bolid ru