1. FJSVscsl ERROR FJSVscsl etc FJSVscslentl disable Please ignore following messages which might be display during switching over between standby SMC and active SMC ERROR FJSVscsl failed to start FJSVscsl did not stop ERROR REASON System console daemon is already working or has not been stopped completely ERROR SOLUTION Execute FJSVscsl stop wait for a while then execute FJSVscsl start again A part of function cannot be succeeded by hot spare SMC Please refer to System Console Software User s Guide for details There are notes in the partition of the server when SMC is used by the redundant configuration When SMC is switched SMC is changed by the scslset command on each partition When hot spare SMC is used SMC is changed by the automatic operation At this time a part of the common filesystem definition defined by another of etc dfs dfstab file is freed Please confirm the common filesystem definition by the share command on each partition beforehand And please set it again after the switch of SMC scslbackup and the scslrestore command should operate by the same Solaris OS version C120 E091 25ENZ2 B 31 52 26 When versions of ESF Enhanced Support Facility of the server for PRIMEPOWER900 1500 2500 HPC2500 sides is 2 3 please apply the following patches Please refer to appendix C of this document for how to apply the patch Patch No 912847 02 The followin
2. 37 52 Appendix A HCP firmware file registration procedure to system console Please install HCP firmware to SMC which is used in or is being to ship to your customer according to the following procedure Some spare part has firmware which is a part of HCP So when you have to replace some part with the spare part you have to match the revision of HCP between what is in the Server and what is in the spare part We are now preparing this procedure about how to match them Anyway HCP should be installed to SCS to download it to spare part The procedure to install the HCP file in system console is as follows Following image is just example Revision number should be different for each Sever Please install HCP which is as same revision as what is installed to Server to SMC Following image is from SCS 1 4 1 or later So if you use SCS 1 38 for example you will see other description But number of the menu item is the same If you have already updated the HCP with this SCS the SCS had already had HCP So you don t have to do the following 1 Please insert the CD ROM of HCP in the drive 2 Please select 5 Hardware Control Program HCP Image Administration from the System Console Machine Administration Menu System Console Machine Administration Menu System Specific Administration Remote Cabinet Interface RCI Administration External Power Control Device Administration UPS Administration Har
3. 788MHz support 5 The following files are added to the file backed up by the scslbackup command etc opt FJSVsirms sirms conf Environment definition file of soft remote maintenance function opt FJSVrmaos etc systemwalker reg File which manages SS Agent var opt FJSVragt etc opasndsys File which manages host name of management server opt FJS Vrlib etc rimomen dft Communication environment configuration file opt FJSVrlib etc rmsmidif dft Device identification information file opt FJSVrlib etc rmsd DRMS management file directory opt FJS Vrlib etc rmscenter dft Center list file at connection destination var opt FJSVmadm etc madmdb Machine management watch information file var opt FJSVmadm etc rptcond Machine management report configuration C120 E091 25ENZ2 B 17 52 file etc opt FJSVmadm optmenuconf Machine management CUI menu options menu definition etc opt FJSVmadm diskswaplist List of disk for machine management revitalization exchange etc opt FJSVmadm nochecklist Machine management watch exclusion device list opt FJSVmadm java com fujitsu web Machine management GUI menu options view madmin optionMenu index txt menu definition var opt FJSVmadm etc madmserver Machine management GUI menu setting conf information file etc opt FJSVwvbs etc webview cnf System requirements definition file
4. 912847 02 and notes 27 Patch 912861 01 is described When the patch is appropriated CD ROM drive uses the System Management Console If you operate the OS console on the System Management Console use the RC2000 In the following description it assumes at the shell prompt that operations performed in the System Management Console window use the SMC and with PRIMEPOWER800 900 1000 1500 2000 2500 HPC2500 and GP7000F Models use the RC2000 1 Insert the System Console Software CD ROM into the CD ROM drive connected to the System Management Console 2 Type su at the shell prompt RC2000 su lt Return gt 3 Enter the root superuser password Password password lt Return gt RC2000 4 Enter the OpenBoot environment RC2000 usr sbin shutdown y g0 i10 lt Return gt 5 Boot the system in single user mode 2 ok boot s lt Return gt When the following message is displayed enter the password INIT SINGLE USER MODE Type Ctrl d to proceed with normal startup or give root password for system maintenance password lt Return gt 6 Mount the required file system RC2000 usr sbin mountall lt Return gt 7 Activate the network RC2000 etc init d inetinit start lt Return gt 8 Start the RPC service RC2000 etc init d rpc start lt Return gt 9 Activate the network interface RC2000 etc init d inetsve start l
5. Note However only when you use Solaris 10 OS and it use Java 2 Runtime Environment Standard Edition Version 1 4 2 8 The following bugs are fixed in SCS 2 6 FJSVclis C120 E091 25ENZ2 B 8 52 e OS installation might be begun while executing temporary boot e Configuration scripts is not executed with reference settings e When the product is installed before Solaris 7 OS the error of umount command is outputed FJSVrcon e The log information extraction library returns an option error and can not extract the log when 16 or lager is specified for the device number SCS82 5 1 1 Improvement of NTP daemon starting conditions of the System Management Console 2 Tape driver definition setting function is supported 3 The function to notify of the path disconnection in non redundant Console Connection Unit configuration is supported Note Please refer to the Notes on the SMC No 39 when you use Solaris 7 OS on the partition 4 When Remote Cabinet Interface RCI Network is not constructed the function to control turning on the power supply is added on PRIMEPOWER900 1500 2500 HPC2500 5 An English menu is improved 6 The following bugs are fixed in SCS 2 5 1 FJSVscsl e Executing scslownerinfo command unnecessary characters in username if comment field of etc passwd file is including spaces FJSVccsl e The Hot Swap Maintenance of FAN FEP installed in Dual Power Cabinet cannot be done on 64CPU model of
6. 42 xxxxx gconfd root ID 702911 user info Exiting This source is what this product prepares it beforehand for the setting and no one which influences the system though the data source for the GConf adaptor of Java Desktop System Configuration Manager is output in the origin as for the above mentioned gconfd message And the java snmpd messages are output due to the trouble of SMA System Management Agent and you cannot use SNMPv3 However SNMPv3 is not used in System Management Console so no problem occurs Therefore do not care about these warning messages disregarding it As for the part of the bold faced type of messages related to above mentioned gconfd the thing controlled by the method of setting the following is possible Method of setting message control 1 In system administrator authority root log in System Management Console 2 Confirm all other users are logging out 3 Stop by the following command when GConf daemon gconfd 2 starts gconftool 2 shutdown 4 Open etc gconf 2 path in the vi editor C120 E091 25ENZ2 B 35 52 vi ete gconf 2 path 5 It is etc gconf 2 path and a comment out as for the following two lines Before the comment out apoc readonly mandatory apoc readonly After the comment out apoc readonly mandatory apoc readonly 2 Example of message 2 Since Solaris 9 OS Oct 25 16 53 43
7. 52 aS pve Dean Nene Use the NFSv4 domain derived by the system Geographic Continent Country Region Continent and Country Asia Japan None No password is set at the shipment of SMC Root Password i If you set no password an warning message appears but since the message does not affect subsequent installation select OK Enabling Remote Select Type of Install Custom Install Select Software aie Unselection Localizations Select System Locale English POSIX C Additional Products ae a Default Packages Entire Group Plus OEM slice system capacity of slice Lay Out File Systems 0 XXXX Mbyte All capacity 4160 Mbyte 1 swap 4096 Mbyte 2 This inquiry will be made if the version of your operating system is Solaris 10 OS 8 07 or later 3 This inquiry will be made if the version of your operating system is Solaris 10 OS 11 06 or later 4 Please there is no influence in the installation work and select Accept though the following error messages are output by the default route check when information is confirmed The route could not be detected at this time If you wish to accept the settings provided press Accept and auto detection will be set for reboot otherwise press Cancel and provide another address 2 1 About the setting after installation 1 Please input lt Return gt or no to NFSv4 in SMC for the unsupport though the following messages are output by the r
8. 52 e Incorrect time prints on the hard error log when it changes to summertime Chapter5 Notes on the SMC 1 The System Console Software 2 3 had been installed and has been tested on following environment gt Solaris 7 8 99 Solaris 7 11 99 Solaris 8 07 01 Solaris 8 11 01 Solaris 8 2 02 Solaris 9 4 03 Solaris 9 8 03 Not for PRIMEPOWER800 1000 2000 or GP7000F Model 1000 2000 VV VV V WV 2 If the SMC platform has the Enhanced Support Facility or the Basic Software Extension or any of the following packages FJSVscdx FJSVscd FJSVscr FJSVscu installed execute the esfrm or the bserm command or the pkgrm command before installing System Console Software 3 System Control LAN is a private LAN Therefore this LAN cannot be connected to a user LAN public LAN 4 The SMC s RCI interface is not supported Do not use the RCI network to connect the SMC platform to the PRIMEPOWER800 1000 2000 900 1500 2500 HPC2500 or GP7000F Model 1000 2000 5 Automatic power control and the mode of operation after power restoration of the SMC platform cannot be set But automatic power control and the mode of C120 E091 25ENZ2 B 27 52 operation after power restoration of the PRIMEPOWER800 1000 2000 and PRIMEOPWER900 1500 2500 HPC2500 and GP7000F Model 1000 2000 can be controlled from the SMC 6 To make the compression function of the DAT device effective the file Kernel drv st conf must be changed Ple
9. GP7000F Model 1000 2000 one server can be set by 15 partitions or less But following number of windows is assumed to manage partitions Up to 16 RC2000 windows at the same time on a machine with 256MB of main memory However the number of above mentioned windows decreases by the number of another window Netscape etc If you want to use more than 16 windows please add main memory to SMC When your system has 512MB main memory you may be able to have up to 32 windows However the number of windows may be decreased when you open any other windows such as for Netscape 5 Please increase it if necessary in consideration of the resource such as memory disk of each product when you install the following software Java version RC2000 which is option of System Console Software package WebSysAdmin Other management software Please consult Fujitsu engineer about details 6 System Management Console is a device to do a watch and various settings of the main body processor Please do not install software which influences the System Management Console function and do not use it by other usages It becomes application and operation by the customer responsibility excluding the test of program operation ending software in System Management Console 7 Operation with two or more Ethernet Card is not supported C120 E091 25ENZ2 B 44 52 Appendix C Procedure to apply patch The procedure to apply patches of notes 23 Patch 912071 01 26 Patch
10. X was disconnected In this case the Console path Configuration Displays menu tells that the status of the path is fail When this phenomenon occurs please confirm the status of the path after starting OS next time If the status is still fail even after the OS started the Console path may have broken Please call a fujitsu engineer When the status becomes active or standby there is no problem 33 In hot spare System Management Console composition if Service Standby is changed Master Slave of the system control LAN may change Then since the C120 E091 25ENZ2 B 33 52 following messages are displayed and SCF 0 returns to Master it does not have influence on employment machine0 FJSVcsl I SCF The switch to Master SCF 0 was completed addr xxxxxxxx 34 The following messages may be displayed at the time of the System power ON machine0 FJSVcsl I console 1 power on instruction failed Since it may generate during a SCF switch please perform System power supply instruction again after checking the state of the system control LAN 35 If dre disconnect sbxx keep is executed with PRIMEPOWER900 1500 2500 which supports the DR function and drkeepcancel machiney xx is executed immediately after the end of the disconnect processing the phenomenon the partition that the SB belongs seeming to drop to OBP suddenly might be generated drkeepcancel Open and execute one time of the minute or
11. e The trouble that even if the malfunction of SCF LAN is restored after the switch of SCF by malfunction the restoration switch processing of SCF is not done is corrected C120 E091 25ENZ2 B 21 52 SCS1 5 2 The patches for SCS1 5 1 or SCS1 5 and the packages of SCS are included in SCS1 5 2 SCS1 5 2 has included the patch of SCS1 5 1 The content added with the patch of SCS1 5 2 is as follows 910852 03 FJSVcsl e Status display of the Partition Display menu is corrected e Installation procedure of a Spare System Console is corrected e Improvements to support of Dynamic Reconfiguration e The trouble that the character on the console window is missed when the server is started is corrected 910909 02 FJSVcslom e Status display of the Partition Display menu is corrected e Installation procedure of a Spare System Console is corrected 911001 01 FJSVscsl e In Spare System Console the problem from which the NTP daemon is not started is corrected 911005 02 FJSVrcon e Console window is closed abnormally during operating with vi editor e The trouble that an error is in the authority of the extracted file is corrected 911056 01 FJSVrcon e The problem from which the path name of the directory which copied the Solaris CD is registered only up to 31 characters in etc dfs dfstab is corrected SCS1 5 1 910852 02 FJSVcsl e Support of Dynamic Reconfiguration e Support of Console Connection Unit duplex system e Support of micro pr
12. lt Return gt mkfile lt nnn gt m smcswap lt Return gt Specify the size nnn in M bytes of the added swap file Add the following one line into etc vfstab file to add the entry for the swap file opt smcswap swap no Reboot the system usr sbin shutdown g0 y i6 lt Return gt After log in verify that one line of opt smcswap is added usr sbin swap l lt Return gt swapfile dev swaplo blocks free dev dsk c1t0d0s1 XX X XX XXXXXXX XXXXXXX opt smcswap XX XXXXXXX XXXXXXX C120 E091 25ENZ2 B 47 52 Appendix E PRIMEPOWER250 SMC Preinstall information The installation and setting the following software are done and PRIMEPOWER250 SMC System Management Console is shipped 1 Install Contents of Solaris 8 9 Operating System Default Route Solaris 9 only Detect one upon reboot Configure Security Tae mone Geograpnic Geographic Region Asia Eastern Time zone Japan Region Available Solaris R Solare arouns Entire Distribution plus OEM support Installed with 64 bit and i slice system capacity of slice Arrangement of file 0 XXXX Mbyte All capacity 4160 Mbyte system and disk 1 swap 4096 Mbyte 2 overlap All capacity 2 Install Contents of Solaris 10 Operating System Select a Language 0 English Network Connectivity Networked Configure Multiple Network Interfaces ieee DHCP C120 E091 25ENZ2 B 48
13. might not be deleted from etc bootparams C120 E091 25ENZ2 B 16 52 The disk slice change operation message set with partiton_setup is improper FJSVesl Only 15 characters can be originally used for the machine name but 16 characters might be registered by the System Network Administration menu In the Console Connection Unit CCU Setup menu the setting of the CCU device up to eight ports is supported Remote Cabinet Interface RCI Administration Menu might be suddenly terminated and return to the top menu during configuring RCI network In the Dynamic Reconfiguration Hot System Board Maintenance menu an unnecessary message might be displayed on Confirmation menu of System Board configuration after System Board replacement The setting of the sender e mail address cannot be deleted by the System Notification Administration menu The SCF replacement might be failed after MAIN LINE SWITCH of the server was turned off even once after SCF breaks down Update of Hardware Control Program HCP POST menu might terminate abnormally by the timeout of System Power on complete The Update of Hardware Control Program HCP POST might terminate with displaying the LEVELUP fail message The SCF replacement might be failed at the RCI multi group environment SCS2 0 1 1 New I O PGX64 Color Frame Buffer support 2 New I O Quad Fast Ethernet PW type support 3 Improvement of log collection function 4 SPARC64 GP
14. more after the dre disconnect sbxx keep command ends when you execute the command 36 If you will install a product with the partition installer to the partition where Solaris 10 OS has been installed the product should support Solaris 10 OS Refer to an installation guide of each product whether a product supports Solaris 10 OS 37 The following console path disconnecting message is displayed though the path is alive when Solaris 7 OS is used on the partition Console path of Cabinet y SB a in Partition X was disconnected In this case please execute the following commands and stop the path monitoring funcition opt FJS Vcsl bin cmdconspath sid Server ID pid Partition D check OFF 38 There is no problem in operation though the following messages might be output to the watch message while operating SMC 1 Example of message 1 Only Solaris 10 OS Mar 19 18 20 46 xxxxx java 17549 ID 610730 user error pkcs11_softtoken Cannot create keystore Mar 20 12 18 13 xxxxx snmpd 95 ID 874347 user error libpkcs11 open var run kefd_door No such file or directory Mar 20 12 18 13 xxxxx snmpd 95 ID 246985 user error libpkces11 ust lib security 64 pkcs11_softtoken so unexpected failure in ELF signature verification System may have been tampered with Cannot continue parsing etc crypto pkcs1 1 conf Mar 20 12 19 32 xxxxx java 1865 ID 807473 user error pkcs11_softtoken K
15. of SMC System Management Console rises The update of the RASDB fails when the Hardware Control Program HCP update is executed concurrently to two or more systems The HCP Hardware Control Program versions may not be correctly C120 E091 25ENZ2 B 12 52 SCS2 3 displayed after the HCP update in the Hot spare SMC System Management Console configuration The XB DDC is not display in Hardware configuration display menu after the XB DDC Hot swap or Cold System Maintenance Breaker on on PRIMEPOWER1500 The CPU cash size displayed in Hardware configuration display menu is incorrect on PRIMEPOWER2500 HPC2500 The Extended Interleave mode is not changed properly after the partition configuration is changed The Cache Way information of CPU may not be displayed at Hardware configuration display menu The Memory unit location name displayed in the Machine Administration Message is incorrect The HCP Hardware Control Program files are added to the candidate for backup which is gatherd by the scslbackup 1M command 1 PRIMEPOWER 250 SMC support 2 In PRIMEPOWER900 1500 2500 HPC2500 the firmware update function in the state of the system operation is supported 3 8GByte memory module in PRIMEPOWER900 1500 is supported 4 16GByte memory module in PRIMEPOWER2500 HPC2500 is supported 5 The following bugs are fixed in SCS 2 3 FJSVrcon When a lot of console windows are started at the same time data might not be d
16. power supply turning on of the server is not done on schedule is corrected because the time of server and the time of SMC are different e Improvements to support of duplex SCF composition 910687 02 FJSVcslom e The message changed by duplex SCF composition support is reflected in the manual SCS1 4 1 The patches for SCS1 4 and SCS are included in SCS1 4 1 The main points of difference in SCS1 4 1 are as follows 1 Improvements to The Machine Administration Menu 2 Improved security 3 Support of duplex SCF composition The Machine Administration supports duplex SCF composition on the PRIMEPOWER800 1000 2000 or GP7000F Model 1000 2000 C120 E091 25ENZ2 B 24 52 The content of each patch is as follows 910685 01 FJSVcsl An English description of the Machine Administration Menu has been improved comprehensible Improved security Support of duplex SCF composition Correction of problem which outputs core dumps by daemon and command and terminates abnormally Changes to the IP library correcting a problem that causes abnormal termination A problem concerning the recovery process not fixing communication breaks following a cable problem after a SCF reset is corrected Correction of the problem directory deletion under var opt FJSVcsl The problem that RC2000 is suddenly cut and cannot be used is corrected The problem where partition ID after the system board is exchanged by the Hot System Board Replacement menu dis
17. xxxxx lockd 253 ID 841824 user error Unable to use FX scheduler Invalid argument Using system default scheduler 39 When the following multiple failures occur the failover by Hot Spare Configration is not done The error occurred in the port of System Control LAN 1 of SMC in the state of Standby and the error occurred in SMC in the state of Service 40 When SMC starts it might make core file in the root directory However there are no problems in the operation of SMC and the operation of the system 41 RC2000 remanager might output a core file if smc is shutdown or a user logs off smc while the console window is open This is a program termination error and the subsequent operations will not be affected Please delete the core file The core file will not be created if smc is shutdown or a user logs off smc after closing all the console windows 42 The following messages may appear during the start of FJVTS in the environment of Solaris 9 OS or Solaris 10 OS but there is no problem with your system Examples of Messages Aug 10 09 51 08 xxxxx SunVTS5 1ps3 Warning cXtXdXsX disk Probable Cause No C120 E091 25ENZ2 B 36 52 media in the drive or Aug 10 09 51 08 xxxxx SunVTSS 1 Error cXtXdXsX disk Probable Cause No media in the drive cXtXdXsX is the device name of the CD drive of System Management Console 43 When you try NFS mount of CD DVD drive of S
18. 0 The System Board Maintenance menu might display the message that there are some adaptor which is connected to the powered device though they are not installed in PRIMEPOWER900 1500 2500 HPC2500 The information on an error may be insufficient on PRIMEPOWER900 1500 2500 HPC2500 The message is mistaken if the All System Power OFF Instruction is performed into System Power OFF on PRIMEPOWER HPC2500 The number of firmware version may not be agreement after the Cold System Control Facility SCF Maintenance on PRIMEPOWER1500 2500 HPC2500 The two same error logs may be extracted on PRIMEPOWER900 1500 2500 HPC2500 Serial information may not be added when the error of NAB occurs on PRIMEPOWER2500 HPC2500 Hot System Expansion of TN FAN and TN FEP cannot be performed on PRIMEPOWER HPC2500 The error message may be displayed after System network activation on PRIMEPOWER900 1500 2500 HPC2500 The Hardware Configuration Displays of FAN installed in Dual Power Cabinet is wrong on 64CPU model of PRIMEPOWER2500 HPC2500 The Hot Swap Maintenance of FAN FEP installed in Dual Power Cabinet cannot be done on 64CPU model of PRIMEPOWER2500 HPC2500 FJSVecsl FJSVkcsl The function of SCS might stop when a specific port of SMC is accessed The daemon which operates on SMC might become abnormal by an illegal C120 E091 25ENZ2 B 11 52 TCP connection The console function by RC2000 might not be displayed FJSVrrda SC82 4 When t
19. 000 2000 controller Please refer to Appendix E PRIMEPOWER250 SMC Preinstall information about pre installation information of PRIMEPOWER250SMC System Management Console About products other than PRIMEPOWER250SMC please refer to CHAPTERT4 Installing the SMC in PRIMEPOWER XXXX Installation Guide XXXX Model name C120 E091 25ENZ2 B 4 52 Chapter2 Disk slice For the System Console Software to operate and correctly control and monitor the status of PRIMEPOWER800 1000 2000 900 1500 2500 HPC2500 or GP7000F Model 1000 2000 the SMC sets up two disk slices These are used for the various large logs of the PRIMEPOWER or GP7000F If the SMC s disk is divided in another slice pattern the SMC cannot function correctly For example causing hard disk overflow How to slice the disk is shown below When the internal dis k is less than 10GB Slice Mount Point Size MB 0 root overlap swap 20 1 swap 256 2 overlap All 3 4 5 6 7 When the internal disk is 18GB or 20GB Slice Mount Point Size MB 0 root overlap swapt 64 1 swap 2048 2 overlap All 3 4 5 6 7 When the internal disk is more than 36GB 1 Slice Mount Point Size GB 0 root 20 1 swap 4 2 overlap All 3 4 5 6 7 1 Please allocate the remain capacity freely Please refer to appendix D for the method of adding the swap space
20. C120 E091 25ENZ2 B System Console Software 2 6 1 Release Notes FUJITSU Preface This document provides the notes for use when a GP7000F Model 200 PRIMEPOWER100 200 250 or similar equipment is used as a System Management Console SMC Ensure that you read these notes when installing the System Console Software SCS Chapter1 Before installing the System Console Software Please note the following requirements for the SMC gt gt gt gt gt gt Memory 256 MB or more Hard Disk 9 1 GB or more More than two PCI slots CD ROM or DVD ROM drive DAT device DDS 3 or DDS 4 or DAT72 standard A Sun compatible keyboard e Display gt gt Resolution 1152 x 900 or 1280 x 1024 Connector standard D sub15pin or 13W3 e Standard PCI cards gt One PGX32 Color Frame Buffer Or One PGX64 Color Frame Buffer Or One XVR 100 Graphics Accelerator One or two Fast Ethernet card s When PRIMEPOWER200 is used as the SMC Or Quad Fast Ethernet card When PRIMEPOWER200 is used as the SMC card of PW type Or Quad Fast Ethernet card When PRIMEPOWER100 is used as the SMC Or Quad Fast Ethernet card When PRIMEPOWER250 is used as the SMC Or Quad Gigabit Ethernet card When PRIMEPOWER250 is used as the SMC C120 E091 25ENZ2 B 1 52 Ensure that the PCI cards are installed in their correct positions and that all cabling is correct Incorrect mounting of PCI cards and cable connecti
21. C120 E091 25ENZ2 B 5 52 Chapter3 Outline functions of SCS 2 6 1 No Component Package Function name 1 Console FJSVscs The version information of each components of the Information System Console Software 2 Machine FJSVesl The system control management or the system Administration FJSVkcsl status patrol of the server FJSVccsl FJSVmadm Supports system operation and maintenance FJSVmand depending on the platform used by the SMC FJSVpmnd FJSVmasv FJSVmaom 3 Online Manual FJSVcslom Online manual of the System Console Software HTML format 4 Automatic FJSVapcs Automatic power control of the server Power Control 5 Partition FJSVclis Supplementary tool to install OS and product in the Installer partition of the server 6 RC2000 FJSVrcon Control of the remote console screen for each partition of the server 7 Dump Control FJSVdmp Retention and management of dumps for each partition of the server 8 System Data FJSVsnap Collects data in the SMC of command execution Output tool results plus hardware and software configuration environment settings logs and operation status then outputs that system information for system fault analysis to a backup tape device 9 SMC FJSVscsl Supplementary tool of the SMC Assistance 10 SCF driver FJSVscd RAS control device driver 1 SMC exclusive FJSVscdx use FJSVscr FJSVscu FJSVlscd RAS control device driver 2 FJSVIscdx FJSV
22. CI DISKBOX replacement Cannel cable disconnect connect at System Board power on state Add Unit detail information to NAB NDB Node Address Board Node Data Board failure messages Using system maintenance mode in PCI DISKBOX Hot System Expansion 1 XPAR eXtended PARtitioning DR Dynamic Reconfiguration support for PRIMEPOWER900 1500 2 Hot spare SMC support for PRIMEPOWER900 1500 2500 HPC2500 3 The monitoring message to notify the change of the setting value on the Panel 4 The following bugs are fixed in SCS 2 2 FJSVesl FJSCkcsl The SCS Administration Information Backup might fail The display the configuration window might not be reflected after changing the partition configuration by node_control command The error log collecting daemon hangs up when the error log happens frequently Hardware fatal error analysis might not conclude for 2 or more cabinet C120 E091 25ENZ2 B 14 52 SCS2 1 1 configuration When SMC is rebooted in hot spare SMC configuration IP address of two SMCs might become the same When DNS is not correctly set hot spare SMC configuration might not be correctly set The synchronization of the information might fail with hot spare SMC configuration When the state of peer SMC is Fail the server cannot be maintained in hot spare SMC configuration When Service SMC is rebooted an unnecessary message might be displayed in hot spare SMC configuration In a redundant console path environme
23. PRIMEPOWER2500 HPC2500 e The Hardware Configuration Displays of FAN installed in Dual Power Cabinet is wrong on 64CPU model of PRIMEPOWER2500 HPC2500 FJSVcsl e The System Network IP Address Modification menu might terminate abnormally when the menu is continuously executed e The RCI Device Status Check Timeout Administration menu might be able to be used though it is a system to which the function of the menu is invalid FJSVkcsl e System Network Activation menu execution for multiple nodes might fail in C120 E091 25ENZ2 B 9 52 GP7000F model 1000 2000 PRIMEPOWER800 1000 2000 SCS2 5 1 New I O XVR 100 DAT72 is supported on PRIMEPOWER250SMC 2 The CPU Frequency 1 89GHz SPARC64 V supported on PRIMEPOWER900 1500 3 PCI DISKBOX Maintenance menu was modify on PRIMEPOWER900 1500 2500 HPC2500 4 The messages of exchange failure in the Maintenance Swapping Administration menu was modified on PRIMEPOWER1500 2500 HPC2500 5 The CPU Frequency 1 82GHz 2 08GHz SPARC64 V supported on PRIMEPOWER2500 HPC2500 6 The warning message at the time of the omission in RASDB registration is added on PRIMEPOWER2500 HPC2500 7 Systemwalker Resource Coordinator V12 0 correspondence In partition_setup and Java version RC2000 it corresponds so that it can be used with Systemwalker Resource Coordinator V12 0 environment 8 The following functions of partition_setup are supported e Installation of Solaris10 is supported e Tempor
24. RODUCT TEST RECORD HCP version can be confirmed 12 It is necessary to register HCP Hardware Control Program file to SMC Please refer to appendix A for registration method 13 HCP Hardware Control Program version 05 07 0000 or later and ESF Enhanced Support Facility version 1 7 1 or later supports the Dynamic Reconfiguration When server is PRIMEPOWER800 1000 2000 or GP7000F Model 1000 2000 14 In order to install SynfinityCluster 2 0 refer to 7 3 2 4 Executing the Partition Installer in System Console Software User s Guide 15 The duplex composition of Console Connection Unit is supported with ESF Enhanced Support Facility version 1 7 1 or later It is necessary to apply the following patch when this function is used with ESF 1 7 1 or 1 8 Patch No 911073 01 The function for diagnosing standby console path automatically on the duplex Console Connection Unit system is supported by ESF2 0 or later 16 When using the duplex composition of Console Connection Unit the message that console path is disconnected and connected may be displayed during Dynamic Reconfiguration operation It is no problem 17 If a lot of text data is pasted on the console window of RC2000 the console message seN Buffer overrun N is an integer may be displayed and some pasted may be missing Please divide the number of times to paste and paste with a size about 1024 bytes at each time In addition this a
25. XVR 100 graphics accelerator for PRIMEPOWER on Sun XVR 100 graphics accelerator CD ROM for the installation method 5 System Console Software install Regarding installation instructions for installing System Console Software refer to INSTALLATION GUIDE System Console Software 6 Solaris PTF install You need to install Solaris PTF and Solaris Unbundled PTF PRIMEPOWER GP7000F Disc 2 for Solaris OS on SMC Regarding instructions for installing Solaris PTF refer to PTF Guide Solaris PTF If you want to install Solaris Unbundled PTF PRIMEPOWER GP7000F Disc 2 use the scspatchadd command Regarding the scspatchadd command and the installation procedure refer to PTF Guide Solaris Unbundled PTF 7 The setting of DAT device to kernel drv st conf file is set with Tape driver configuration tool automatically and as follows Refer to Tape driver configuration tool User s Guide for details tape config list SEAGATE DAT DAT72 000 SEAGATE DAT DAT72 000 SEAGATE DAT DAT72 000 SEAGATE DAT DAT72 000 1 0x34 0 0x9639 4 0x00 0x8c Ox8c 0x8c 3 Please input to the following commands and confirm hardware information usr sbin prtconf v C120 E091 25ENZ2 B 52 52
26. appears is corrected The problem that the longevity of UPS battery is notified by always using the server name of the Oth server ID is corrected 910686 01 FJSVscsl Improved security 910687 01 FJSVcslom SCS1 4 The change in the Machine Administration Menu is reflected in the manual The message added by duplex SCF composition support is reflected in the manual A wrong description was corrected 1 SPARC64 GP 450MHz 440MHz 400MHz support A field upgrade menu is added to the SCS Machine Administration menu in order to add SPARC64 GP 450MHz 440MHz 400MHz processors The SCS also provides a firmware updated function It is necessary to upgrade the POST and the SCF firmware 2 PRIMEPOWER brand The SCS now recognizes the product name PRIMEPOWER 3 Separation of the FUJITSU REMCS packages The FUJITSU REMCS the FUJITSU s remote maintenance packages are C120 E091 25ENZ2 B 25 52 separated from the SCS 1 4 CD As a result some menu items relevant to remote maintenance are removed from the Machine Administration Menu in the SCS The remote maintenance packages will now be provided on another CD 4 Support for the installation of Solaris 2 6 on PRIMEPOWER and GP7000F The Partition installer now supports the installation of Solaris 2 6 on PRIMEPOWER800 1000 2000 or GP7000F Model 1000 2000 The following bug are fixed in SCS 1 4 1 RC2000 FJSVrceon e Unable to use locale except C or ja in
27. ary boot is assumed to be unnecessary e Revokable is made the priority of the installation script e The CD image can be copied to the product of two or more piece CD composition e Improvement of selection method and product installation log collection 9 Improvement of log collection function 10 PRIMEPOWER Server Manager be able to get server information 11 The following functions in FJSVsnap are changed e System information related to Machine Administration is added to the collected data serialid hcpversion e Default work area is changed from tmp to var tmp e When free space of the work area is smaller than the total size of collected data the process terminates with an error e _ Files directories which exceed the upper limit 128MB are not collected 12 The following bugs are fixed in SCS 2 5 FJSVclis e When Solaris9 9 04 is installed grmpdautoconf terminates abnormally at C120 E091 25ENZ2 B 10 52 temporary boot When the version of OS of SMC Installation server and target server is different grmpdautoconf terminates abnormally at temporary boot FJSVccsl In the Hardware Configuration Displays menu Status information may be displayed numerically OS information at the time of Panic generating is insufficient The DTB mounted in the Cabinet 1 is displayed as Cabinet 0 DTB 1 on PRIMEPOWER HPC2500 An error messages is not displayed at the time of failure in TN setup menu on PRIMEPOWER HPC250
28. ase refer to the manual of the SMC platform and modify the st conf file 7 Also refer to Chapter 5 Notes after the Installation in PRIMEPOWER200 400 600 and GP7000F Model 200 200R 400R 400A 600 600R Hardware Platform Guide Solaris 8 Please refer to the Enhanced Support Facility manual for PRIMEPOWER800 1000 2000 900 1500 2500 HPC2500 or GP7000F Model 1000 2000 about how to operate the SCF driver and the Machine Administration for the SMC 9 The console path between the RS 232C port on the system board and the SMC through the console connection unit uses the smallest number of the system boards and the second smallest number of system boards in the partition 10 While the System network change is executing do not interrupt the process by using the Control C key Doing do will cause the system control of PRIMEPOWER or GP7000F to fail 11 HCP Hardware Control Program version 02 11 0000 or later supports the duplex SCF composition When server is PRIMEPOWERS800 1000 2000 or GP7000F Model 1000 2000 Version of HCP can be confirmed by the following commands usr sbin hcpversion lt Server_name gt Examples usr sbin hcpversion server0 HCP Total Revision 08 03 0000 When version up of HCP is never done the following messages are output usr sbin hcpversion server0 C120 E091 25ENZ2 B 28 52 No HCP has been updated from SMC In this case please refer to P
29. can support eight servers or less 2 When server is PRIMEPOWER900 1500 2500 HPC2500 the internal disk is necessary for SMC by 18GB or more About System Management Console SMC operation 3 There are the following remarks concerning the number of partitions when PRIMEPOWER900 1500 2500 is controlled with PRIMEPOWER100 200 SMC Relation between number of partitions and memory capacity on the PRIMEPOWER100 SMC Memory Swap Number of 256MB 2GBor 512MB 2GBor_ 768MB 2GB or partitions more Standard more Add more Add conf 256MB Memory 512MB Memory Up to 4 OK OK OK Up to 8 OK OK OK Up to 12 NG OK OK Up to 16 NG OK OK The response in the operation menu deteriorates when the WSA server is installed in the SMC Relation between number of partitions and memory capacity on the PRIMEPOWER250 SMC Memory Swap Number of 1GB 4GB or 2GB 4GB or 3GB 4GB or partitions more Standard more Add 1GB more Add 2GB conf Memory Memory Up to 16 OK OK OK Up to 24 OK OK OK Up to 32 OK OK OK Up to 48 NG OK OK The response in the operation menu deteriorates when the WSA server is installed in the SMC Please add the memory of SMC according to the number of partitions The number of windows of RC2000 which always opens recommends about 16 windows C120 E091 25ENZ2 B 43 52 4 When server is PRIMEPOWER800 1000 2000 or
30. change an environment definition which the NFS server and is both NFS client to NFS version 3 according to the following procedures because NES version 4 in Solaris 10 OS is a limitation The following parts of etc default nfs file are added Sets the maximum version of the NFS protocol that will be registered and offered by the server The default is 4 NFS_ SERVER VERSMAX 4 NFS_ SERVER VERSMAX 3 lt This definition is added Sets the maximum version of the NFS protocol that will be used by the NFS client Can be overridden by the vers NFS mount option If vers is not specified for an NFS mount this is the version that will be attempted first The default is 4 NFS_ CLIENT VERSMAX 4 NFS_CLIENT_VERSMAX 3 lt This definition is added The NES server service is reactivated C120 E091 25ENZ2 B 50 52 svcadm disable network nfs server svcadm enable network nfs server 4 etc gconf 2 path file is edited Please comment out like below in the etc gconf 2 path file to restrain SMC monitoring messages from outputting warning messages related to gconfd apoc readonly mandatory lt Please add in the head of this definition to comment out apoc readonly lt Please add in the head of this definition to comment out SMC with SolarisTM 10 OS 8 07 pre installed has the above settings 2 2 About notes of Solaris 10 OS 8 07 1 Name Service Cache Daem
31. dware Control Program HCP Image Administration System Console Software SCS Administration System Network Administration Miscellaneous Administration 1 2 3 4 5 6 7 8 q Quit h Help Select 1 8 q h 5 lt tplease input 5 C120 E091 25ENZ2 B 38 52 3 Please select CD ROM from the Hardware Control Program HCP Image Administration menu Hardware Control Program HCP Image Administration 1 Display of Hardware Control Program HCP Image s Stored on SMC 2 Hardware Control Program HCP Image Administration menu t Go to top menu h Help please input 2 Select 1 2 q b t 2 Hardware Control Program HCP Image Administration 1 CD ROM 2 Work Area WARNING This operation should be performed by trained service personnel only q Quit b Back to previous menu t Go to top menu h Help Select 1 2 q b 01 4 4 Please confirm the Total Revision level of a HCP to register and input one Hardware Control Program HCP Image Administration No Total Revision Build Date 1 00 22 0000 2000 04 25 07 49 39 q Quit q Quit b Back to previous menu t Go to top menu h Help Select 1 q b t 1 C120 E091 25ENZ2 B 39 52 5 Total Revision 00 22 0000 Unit SCF Board LCI SCF Board SCF SCF Board OBP XB DDC LCI FAN LCI Panel Board LCI Panel Board NCI FEP LCI System Board LCI System Board POST Please confirm each device e c level in integrated e c level a
32. e the following notes Live Upgrade which is the function of Solaris 9 OS is not supported Java version RC2000 is not supported 2 Hot spare SMC support The spare system console function is enhanced and when active SMC stops SCS is automatically switched to the standby side However there is a limitation in the following conditions When you install additional option software on SMC When SMC REMCS agent s function is used Refer to 3 4 SMC REMCS agent release notes for details Please refer to Chapter4 Notes on the SMC for notes 3 Java version RC2000 support Java version RC2000 is supported as an optional feature Java version RC2000 uses Web Based Admin View When the product is shipped Java version RC2000 is not installed in SMC Please refer to Installation Guide System Console Software for the procedure to install it This function is not supported in Solaris 9 OS 4 Support of RCI Device Status Check Timeout value automatic setting function 5 In the Console Connection Unit CCU Setup menu the setting of the CCU device up to eight ports is supported 6 The display of firmware revisions of each sub components is added to the hepversion command 7 The menu of Display the OS Information is added to the Status Report Log menu in the System Log Displays menu 8 The following bugs are fixed in SCS 2 1 FJSVclis e When the host is deleted from the host list with partition_setup pertinent host s information
33. eboot after the installation is completed Attention The following messages are not output in Solaris 10 OS 8 07 Do you need to override the system s default NFS version 4 domain name yes no no Please change an environment definition which the NFS server and is both NFS client to NFS version 3 according to the following procedures and C120 E091 25ENZ2 B 49 52 operate it after completing the reboot 2 Sun Update Manager Registration Wizard or Solaris Manager Registration Wizard may be displayed after logging in to the system where Solaris 10 OS has been installed Corrective action of Sun Update Manager Registration Wizard Select Never Register and press Next because Sun Update Manager is unsupported Please select Discard Registration when the following message appears after executing this procedure Cancelling the registrarion process will discard the information you have entered Please either confirm that you wish to exit or instead continue Corrective action of Solaris Registration Wizard Select Run the Solaris software without registering and press Next because Solaris Registration is unsupported Please select Never Register when the following message appears after executing this procedure If you choose to never register you will not be able to obtain the benefits of Solaris registration with Sun 3 etc default nfs file is edited Please
34. eystore C120 E091 25ENZ2 B 34 52 version failure Mar 20 13 21 12 xxxxx gconfd root ID 702911 user info starting version 2 6 1 pid 4629 user root Mar 20 13 21 12 xxxxx gconfd root ID 702911 user warning ApocSource Source apoc readonly mandatory is unavailable Failed ApocPapi Cannot initialise PAPI PAPI Connection Failure Mar 20 13 21 12 xxxxx gconfd root ID 702911 user warning ApocSource Source apoc readonly is unavailable Failed ApocPapi Cannot initialise PAPI PAPI Connection Failure Mar 20 13 21 12 xxxxx gconfd root ID 702911 user info Resolved address xml readonly etc gconf gconf xml mandatory to a read only config source at position 0 Mar 20 13 21 12 xxxxx gconfd root ID 702911 user info Resolved address apoc readonly mandatory to a read only config source at position 1 Mar 20 13 21 12 xxxxx gconfd root ID 702911 user info Resolved address xml readwrite gconf to a writable config source at position 2 Mar 20 13 21 12 xxxxx gconfd root ID 702911 user info Resolved address apoc readonly to a read only config source at position 3 Mar 20 13 21 12 xxxxx gconfd root ID 702911 user info Resolved address xml readonly etc gconf gconf xml defaults to a read only config source at position 4 Mar 20 13 21 42 xxxxx gconfd root ID 702911 user info GConf server is not in use shutting down Mar 20 13 21
35. for Web Based Admin View etc opt FJSVwvbs etc wvlocal cnf System requirements definition file for Web Based Admin View machine peculiar information SCS2 0 1 The following functions of partition_setup are supported e The specification change to save the system presetting information for the network boot e The function addition to enable to install the host of a new model e The function addition to enable to install the multiple languages locales e The function addition to enable to install the packages only for Solaris 32 bit e The specification change to enable to set the installation information of the version since Solaris 9 2 RCI multi group administration support 3 The Hardware Control Program HCP Update Administration menu supports online updating mode 4 The following bugs are fixed in SCS 2 0 FJSVclis e After the product CD image was copied by partition_setup the network installation of the product cannot be performed if you release manually the share and execute partition_setup again FJSVrcon e Aconsole log when errors occur to the server might be unable to be gained e When the Send Break menu of the console window is executed Telnet Break might be sent two or more times FJSVesl e The message SCS Internal error firmctld restart might be displayed on C120 E091 25ENZ2 B 18 52 the Monitoring Message window during shutdown procedure of SMC e When the time out of communication processing wit
36. g bugs are corrected When CPU offline fails the message of the offline success is displayed The result of the inst2comp command is not correctly displayed Hardware configuration information of the network adaptor is not correctly displayed Faulty unit is not correctly displayed by the notification message of the adaptor abnormality 27 When server is PRIMEPOWER900 1500 2500 HPC2500 extended partitioning is supported with ESF Enhanced Support Facility version 2 3 or later It is necessary to apply the following patch when this function is used with ESF 2 3 Please refer to appendix C of this document for how to apply the patch Patch No 912861 01 28 When the hub used to control the system LAN supports the function to prevent the circulation Domain Separation Spanning Tree Protocol etc system control LAN might be disconnected Please nullify the function In the communication setting of system control LAN the setting of the SCF side is 10Mbps half duplex And Quad 10 100 Ethernet card PWO08QE1 on the SMC side depends on a basic setting auto negotiation Please set evasion referring to FUJITSU PCI Quad Ethernet 1 0 Document when there is a problem in the combination with the hub under this condition Please set the setting of the hub to 100Mbps full duplex fixation mode 29 Please confirm an empty size of the disk when you use the disk of SMC with the following tools etc Dump suppor
37. guration gt When you move the System Board to another partition please release the redundant setting beforehand Otherwise following error message which tells an abnormality of the console path may be displayed Console path of Cabinet y SB a in Partition X was disconnected 20 HCP Hardware Control Program version 09 01 0000 or later supports RCI multi group administration When server is PRIMEPOWER800 1000 2000 or GP7000F Model 1000 2000 21 HCP Hardware Control Program version 10 01 0000 or later supports SPARC64 GP 788MHz When server is PRIMEPOWER800 1000 2000 or GP7000F Model 1000 2000 22 There are notes about the operation of SMC Please refer to appendix B C120 E091 25ENZ2 B 30 52 23 24 25 There are notes about hot spare SMC Hot spare SMC is supported with ESF Enhanced Support Facility version 2 2 or later It is necessary to apply the following patch when this function is used with ESF 2 2 Please refer to appendix C of this document for how to apply the patch Patch No 912071 01 Please use Primary_SMC usually Please do not execute the status transition command of the redundant configuration from two SMC at the same time Please use the same version of Solaris OS and System Console software on both the SMC Please connect both the SMC to the same HUB for system control LAN Please ignore following message which might be display during the booting up of the SMC
38. h SCF occur the procedure to stop the processing might kill the other independent processes 5 PGX64 adapter can be diagnosed with m64test on FJVTS 6 Addition of the reported message on the platform used by the SMC 7 PWOO8QE1 adapter support SCS1 7 1 Improvements to use not only the hostname but also Internet Protocol address for etc hostname lt interface gt file of SMC 2 Functions of the scslinstall command are enhanced to automatically apply the following e System Console Software e System Console Software patches e SMC REMCS Agent e SMC REMCS Agent patches 3 Operation improvement of Maintenance Swapping Administration menu in the Machine Administration Menu 4 Support of patrol function for the sub console path 5 Improvement of Hardware Control Program HCP Update Administration function and menu 6 Improvement of hardware log function 7 Improvement of RC2000 function 8 Improvement of time synchronization function between SMC and partition of PRIMEPOWER 800 1000 2000 or GP7000F Model 1000 2000 9 The following bugs are fixed in SCS 1 7 FJSVclis e An unnecessary character string might be displayed on the input screen of the password in partition_setup e The product copied with partition_setup might not be able to be selected from the product list FJSVcsl e When you newly add UPS in the UPS Administration menu the display of dots at the waiting time after UPS is set does not end occa
39. he HTTP communication is canceled The REMCS agent doesn t respond occasionally 1 SPARC64 V 1 89GHz in PRIMEPOWER 900 1500 is supported 2 Systemwalker Resource Coordinator V11 0 1 correspondence In Partition Installer and Java version RC2000 it corresponds so that it can be used with Systemwalker Resource Coordinator V11 0 1 environment 3 The following functions of partition_setup are supported Addition of function authenticated checked internal disk RAID array with temporary OS of installation server before OS is installed and to compose driver configuration file of ETERNUS disk array automatically Addition of installation script arrangement command Addition of OS installation function to use flash archive Addition of synchronous execution function of set script in cluster composition environment Addition of system file distribution function Addition of slice setting omission function of disk To assume network boot temporary boot execution that is the selection to be indispensable for connected confirmation of the disk device the specification is changed Support of the main platform product Improved security 4 The following bugs are fixed in SCS2 4 FJSVccsl The partition setup data may be cleared after Cold System Control Facility SCF Maintenance Breaker Off is executed The Hot Swap Maintenance of FEP is supported on PRIMEPOWER1500 Some processes does not work correctly when the load
40. isplayed in the console window FJSVesl FJSCkcsl The error message when the user who does not have the execution authority operates the menu is improper When the redundant console path s configuration is used and the sub path is used for operation the console on the RC2000 might not be used after the system power OFF and ON The hardware error logs might not be collected The amount of the resource in some processes might expand because of the memory free leakage C120 E091 25ENZ2 B 13 52 When the Hot Spare SMC configuration is used the RC2000 console might not be used for a while after the switching of the SMC FJSVccsl SCS2 2 On PCI DISKBOX Hot System Expansion and Cold System Maintenance Cannot Expansion PCI DISKBOX to initial state SB system board slot The Hot System Board Replacement is performed when System Board is power on but failure state The Hot System Expansion menu displays failure unit The System Board Addition to Partition menu displays wrong partition The CPU that is failure Hardware Configuration menu displays degenerate state always The SCF System Control Facility 0 replacement by Cold System Control Facility SCF Maintenance Breaker Off SCF NVRAM is cleared The Hot System Board Maintenance or Cold System Board Maintenance may be failed On PRIMEPOWER2500 PRIMEPOWER HPC2500 with Dual Power Feed the Hot System Expansion of FAN may be failed The Hot System Board Replacement with P
41. it is installed C120 E091 25ENZ2 B 7 52 Chapter4 New distribution function About the latest manual To see the latest manuals for System Console Software please visit the following URL http www fujitsu com global support software manual Note Manuals included in System Console Software CD ROM main CD and Additional CD ROM Axx are not up to date SCS2 6 1 1 New CPU 1 65GHz and new I O Quad Gigabit Ethernet PW type are supported on PRIMEPOWER250SMC 2 Java 2 Runtime Environment Standard Edition Version 1 3 1_17 is supported 3 An English menu and messages are improved 4 The following function of partition_setup is supported e When Solaris 10 OS is installed with the partition installer GR multipass driver of the temporary boot can be set SCS2 6 1 For Solaris 10 OS 2 Addition of ACFAIL occerd message level modification function 3 A new function Security enhancement setting of OS console connection is supported 4 The get_console 1M command which operates the OS console is supported 5 The following function of partition_setup is supported e Two or more products can be batch installed with Solaris 10 OS in addition to Enhanced Support Facility 6 SMF Service Management Facility of NTP daemon is supported 7 The following Web browser of Web Based Admin View client is supported e Solaris Workstation Web browser Mozilla Web browser Java bundled in Solaris 10 OS
42. l FJSVapcs e Even if the stop operation of the system is done by the automatic power control the system does not stop occasionally RC2000 FJSVrcon e When Host Browser ends another command that parent process becomes the same is occasionally ended e Console Window might not be able to be started FJSVsnap e The fjsnap command might be doubly started SCS1 4 3 The patches for SCS1 4 2 or SCS1 4 or SCS1 4 1 and SCS are included in SCS1 4 3 C120 E091 25ENZ2 B 23 52 SCS1 4 3 has included the patch of SCS1 4 2 The content added with the patch of SCS1 4 3 is as follows 910685 04 FJSVcsl e The problem of the function to upgrade the POST or SCF firmware in duplex SCF composition is corrected e The processing at the SCF alarm in duplex SCF composition is changed SCS1 4 2 The patches for SCS1 4 1 or SCS1 4 and SCS are included in SCS1 4 2 The content added with the patch of SCS1 4 2 is as follows 910685 03 FJSVcsl e The problem that SMC cannot connect with partition is corrected when 0 is included in IP address of the partition or SMC e In the Maintenance Swapping Administration menu the problem that the Hot Swap etc of SCF cannot be done is corrected e In the Maintenance Swapping Administration menu the HELP message is corrected e Improvements to support of duplex SCF composition 910722 03 FJSVapcs e The problem that access to the server fails in rebooting of SMC is corrected e The problem that the
43. lscr FJSVlscu FJSViomp RAS control device driver 3 FJSVpscd FJSVpscr FJSVpscu 11 Web Based FJSVwvbs WWW server for Web Based Admin View Admin View FJSVwvenf Web Communication base for Web application o Ponor TEIS Dowaload tool for Web Based Admin View or Admin View 12 SMC Default FJSVdef Prevents file system capacity shortage due to Configuration expansion of the system log C120 E091 25ENZ2 B 6 52 No Component Package Function name 13 Validation Test FJSVvts Online diagnosis test of SMC System SUNWvts SUNWvtsmn SUNWvtsx 14 Panel control FJSVpnlx Device driver for panel control 3 driver FJSVpnl 15 Java version FJSVrcon2 RC2000 function is offered with Java 5 RC2000 FJSVrcond The download function of RC2000 package from WevView is offered 5 FJSVrcone Online manual of the RC2000 User s Guide HTML FJSVrconm format 5 16 HRM Server FJSVhrmsc This function supports maintenance work without a system mistake early for the purpose of stable operation of operation a system This function supports Japanese support environment only 4 17 Tape Driver FJSVdenf This function adds configuration parameter of oo target tape device automatically 00 1 GP7000F Model 200 or PRIMEPOWER200 only 2 PRIMEPOWER 100 SMC only 3 PRIMEPOWER 250 SMC only 4 PRIMEPOWER 100 200 250 SMC only 5 Only when javarc option is specified
44. mount of data to paste is a standard because speed of receiving process changes by the application using on the system If you need to paste all data at one time please paste by the mean like the following examples gt Paste data on the text editor of SMC and save as a text file And if required transmit this file to the system by ftp etc C120 E091 25ENZ2 B 29 52 gt Paste data on windows other than RC2000 connected by telnet etc 18 When you install Solaris 9 OS to the partition with the partition installer the interactive installation screen by Solaris OS installation program may be displayed on the console of partition in the following procedure after executing partition_setup Procedure when network boot is executed When you executed the network boot for acquiring the disk information on the installation partition during the setting procedure of the installation information with partition_setup or Procedure when network boot is not executed When you executed the network boot for beginning the network installation after the setting of the installation information was completed by partition_setup Action Please answer to the inquiry according to the indication of screen After you answered all inquiries the installation can return to the regular procedure of network installation or partition_setup to be continued 19 Please note the following when the console path is set as a redundant confi
45. nd input one 2000 04 25 07 49 39 Version 00 03 0000 01 14 0003 11 01 0019 01 00 0000 01 00 0000 01 00 0007 01 00 0000 01 00 0000 01 00 0005 01 02 0001 XB Board LCI 01 00 0003 1 catalog q Quit q Quit b Back to previous menu t Go to top menu h Help Select 1L a b t 1 please input T 6 Please confirm registration has been completed and the menu returns to the Hardware Control Program HCP Image Administration menu Hardware Control Program HCP Image Administration 1 Display of Hardware Control Program HCP Image s Stored on SMC 2 Hardware Control Program HCP Image Administration q Quit b Back to previous menu t Go to top menu h Help Select 1 2 q b t 7 Ifyou have never updated the HCP with this SMC please also do the following Type t then you ll get back to top menu 8 Please confirm the total version number information on the server as follows 1 Beginning of work of version number confirmation Please turn off the power supply of the server The PANEL display is in the state of POWER ON READY And set the PANEL switch in MAINTENANCE C120 E091 25ENZ2 B 40 52 2 Execution of version number adjustment confirmation 1 Please choose the menu of Current Hardware Control Program HCP Revision Display as follows System Console Machine Administration Menul 1 System Specific Administration 5 Hardware Control Program HCP Update Administration 1 Curren
46. nt on the PRIMEPOWER900 1500 2500 the wrong formatted message is displayed In PRIMEPOWER 800 1000 2000 and GP7000F models 1000 2000 The SCF breakdown can not be notified when it was broken before the main line switch of server is turned on In PRIMEPOWER 800 1000 2000 and GP7000F models 1000 2000 The status of mode switch can not be reflected when it was changed while the SMC is stopped 1 PRIMEPOWER900 1500 2500 HPC2500 support However the server which can be managed by one SMC is as follows Combination in GP7000F model 1000 2000 PRIMEPOWER800 1000 2000 model group Combination in PRIMEPOWER900 1500 2500 HPC2500 model group There is a limitation in the following conditions when the server is n PRIMEPOWER900 1500 2500 HPC2500 Hot spare SMC 2 New System Board support 3 The following bugs are fixed in SCS 2 1 1 FJSVcsl FJSCkcsl Automatic backuped information might not be able to be restored in the Restoration of Automatic Backup Information from Partition OS menu The display of RC2000 and the Configuration window might not reflect the addition of the partition or the changing of the server name C120 E091 25ENZ2 B 15 52 e The message of the failure of the status check time out setting is displayed in the SCF maintenance menu when RCI group 0 does not exist e The command drkeepcancel fails SCS2 1 1 Solaris 9 Operating System OS support Solaris 9 OS is supported However there ar
47. ogram POST updating of partition e The omission of the character of the error log message has been corrected e The erratum of the report unit type has been corrected e The trouble that the contents of the partition display menu are different from that of SCF has been corrected e The problem not to be able to delete the partition when status is NG is corrected C120 E091 25ENZ2 B 22 52 e When the server was never started after initial install of SCS the problem to which the micro program could not be updated had been corrected e The description of Solaris 8 of server OS is added 910909 01 FJSVcslom e Support of Dynamic Reconfiguration Change in message e Support of Console Connection Unit duplex system e Support of Solaris 8 on server OS SCS1 5 1 Improved security 2 Function reinforcement of partition installer 3 Operation improvement of RC2000 4 Operation improvement of the Machine Administration Menu 5 System board PP087SB2 PP207SB2 support 6 Overwrite support 7 The following bugs are fixed in SCS 1 5 Machine Administration FJSVcsl e The message of the Partition System Board Administration menu is corrected e When the error notification from partition OS is continuously received the error message is incorrect on SMC SMC Assistance FJSVscsl e underscore enters the hostname of the partition when the hostname of the partition is made from SMC automatically Automatic Power Contro
48. on nscd 1M is not running on the System Management Console for Solaris 10 OS 8 07 because there is a limitation for use of name service cache daemon nscd 1M The following shows how to stop nscd 1M Use the svcadm 1M command to stop the name service cache daemon nscd 1M svcadm disable svc system name service cache default 2 Please be sure to install the latest FJ RSPC after installing the OS if Solaris 10 OS 8 07 is pre installed on SMC Regarding installation instructions and notes on installation refer to a README for FJ RSPC 3 FJ qfe driver pkg or FJ qge driver pkg install Please refer to INSTALLATION GUIDE FUJITSU PCI Quad 10 100 Ethernet or INSTALLATION GUIDE FUJITSU PCI GigabitEthernet on FUJITSU PCI Quad 10 100 Ethernet or FUJITSU PCI GigabitEthernet CD ROM for the installation method The problem is not simultaneously in the patch with OS to have installed it though the following messages might be displayed when FUJITSU PCI GigabitEthernet is installed The following requested patches are already installed on the system Requested to install patch 120462 04 is already installed on the system C120 E091 25ENZ2 B 51 52 No patches to check dependency patchadd 120462 04 exit status 1 See logfile var sadm install logs FJSVgid_cdrom_prodsetup log 4 XVR 100 software Install For Solaris 8 OS Please refer to INSTALLATION GUIDE Sun
49. ons may cause operational difficulties When PRIMEPOWER200 or GP7000F Model 200 is used as the SMC the PCI slot positions are fixed as follows Slot Type of PCI card PCI1 FastEthernet card If the redundant System Control Facility is installed this card is needed for the redundant system control LAN PCI3 FastEthernet card For the basic system control LAN PCI4 PGX32 or PGX64 Color Frame Buffer Slot Type of PCI card PCI3 Quad Fast Ethernet card card of PW type PCI4 PGX32 or PGX64 Color Frame Buffer When PRIMEPOWER100 is used as the SMC the PCI slot positions are fixed as follows Slot Type of PCI card PCH Quad Fast Ethernet card PCI3 PGX32 or PGX64 Color Frame Buffer When PRIMEPOWER250 is used as the SMC the PCI slot positions are fixed as follows Slot Type of PCI card PCIS Quad Fast Ethernet card card of PW type PCI4 PGX64 Color Frame Buffer Slot Type of PCI card PCI5 XVR 100 Graphics Accelerator PCI4 Quad Fast Ethernet card card of PW type Slot Type of PCI card PCI5 XVR 100 Graphics Accelerator PCI4 Quad Gigabit Ethernet card card of PW type C120 E091 25ENZ2 B 2 52 In System Management Console the network interface is used as follows PRIMEPOWER 100 SMC and Quad Fast Ethernet card card of X type Interface Used for eri0 This interface is used to connect SMC and Each partition of Server qfe0 qfel These interfaces are u
50. sed to control System LAN qfe2 qfe3 Please use the port here when you use REMCS agent s function PRIMEPOWER 100 SMC and Quad Fast Ethernet card card of PW type Interface Used for eri0 This interface is used to connect SMC and Each partition of Server fqe0 fiqel These interfaces are used to control System LAN fige2 fjqe3 Please use the port here when you use REMCS agent s function PRIMEPOWER 200 SMC and FastEthernet card Interface This interface is used to connect SMC and Each partition of Server hmel hme2 These interfaces are used to control System LAN PRIMEPOWER 200 250 SMC and Quad Fast Ethernet card card of PW type Interface hme0 Used for This interface is used to connect SMC and Each partition of Server figel fjqe2 These interfaces are used to control System LAN fiqe3 fige4 Please use the port here when you use REMCS agent s function PRIMEPOWER 250 SMC and Quad Gigabit Ethernet card card of PW type Interface hme0 Used for This interface is used to connect SMC and Each partition of Server figi0 figil These interfaces are used to control System LAN figi2 fjgi3 Please use the port here when you use REMCS agent s function Please refer to the following for the Quad FastEthernet card and Quad Gigabit Ethernet card X_type LINKIACT 0123 y i a ee Lad a eee C120 E091 25ENZ2 B An in
51. sionally However setting is normally done C120 E091 25ENZ2 B 19 52 In the Hardware Configuration Displays menu the error mark does not adhere occasionally In the hardware error log menu the retrieval function may not operate normally When Machine Administration Menu ends the work file remains occasionally FJSVapcs The power supply of the server from the Auto Power Control System might not be turned on by the SMC restart When the schedule of Auto Power Control System is displayed the display of the year might be displayed only by the lowest one digit FJSVscsl The messages with the improper additional information named luser error in the Monitoring Window and var adm messages file are output when OS of SMC is Solaris 8 The MAC address of the added partition might not be automatically reflected in etc ethers file FJSVrcon When the Reset and Clear Saved Lines menu of the console window is executed display area might not be cleared Even if ten key are input on the console window the input might be not effective 10 The ability to test CPUs was improved on FJVTS 11 Improvement of Web Based Admin View function 12 Improvement of Machine Administration functions on the platform used by the SMC SCS1 6 2 SCS 1 6 2 is composed of SCS 1 6 1 and additional patch SCS 1 6 2 has following new features 911310 02 FJSVcsl SCS1 6 1 Improvement of Hot system board addition men
52. t Hardware Control Program HCP Revision Display 2 Please select c Version number adjustment confirmation from the screen of Current Hardware Control Program HCP Revision Display MachineO System Specific Administration Current Hardware Control Program HCP Revision Display Current Total Revision Next Total Revision No Unit Current Version Next Version SCF Board OBP SCF Board SCF SCF Board LCI SCF Board SCI SCF Board RCI System Board POST System Board LCI System Board SCI XB Board LCI 10 Panel Board LCI 11 FEP LCI 12 XB DDC LCI 13 FAN LCI m Manual Update a Auto Update When the update by SCS is c Version number adjustment confirmation unapplie d this is displayed Please select number to display Version for each Unit Installed in the server ANoa rhrwNr q Quit b Back to previous menu t Go to top menu h Help Select 1 13 m a c q b t c please input c The thing with correct number of devices of Hardware Control Program HCP versions was confirmed C120 E091 25ENZ2 B 41 52 3 Please confirm the message of The thing with correct number of devices of Hardware Control Program HCP versions was confirmed The total version number to the server comes to be displayed on the screen of Current Hardware Control Program HCP Revision Display by the above mentioned procedure C120 E091 25ENZ2 B 42 52 Appendix B 1 One SMC
53. t Return gt C120 E091 25ENZ2 B 45 52 10 Start the nfs client RC2000 etc init d nfs client start lt Return gt 11 Mount the CD ROM RC2000 mkdir p cdrom lt Return gt RC2000 usr sbin mount F nfs o ro Aost cdrom cdrom0 cdrom lt Return gt host host name of System Management Console 12 Change the directory to the CD ROM drive RC2000 cd cdrom cdrom0 esfpatch lt Return gt 13 The application command of the patch is executed RC2000 usr sbin patchadd patch_number lt Return gt patch_number 912071 01 912847 02 912861 01 14 Unmount the CD ROM RC2000 cd lt Return gt RC2000 usr sbin umount edrom lt Return gt 15 Eject the CD ROM System Console cd lt Return gt System Console eject cdrom lt Return gt C120 E091 25ENZ2 B 46 52 Appendix D Adding More Swapping Space The procedure to add the swap spaces of notes 24 is described 1 2 Login as root And open the Terminal Console Shutdown the SMC to OBP usr sbin shutdown g0 y i0 lt Return gt Boot the system in single user mode ok boot s lt Return gt When the following message is displayed enter the password INIT SINGLE USER MODE Type Ctrl d to proceed with normal startup or give root password for system maintenance password lt Return gt Create the Swap File cd opt
54. t tool Collection of system information Setup of Partition installer Backup of log information HCP firmware file registration Documents registration C120 E091 25ENZ2 B 32 52 30 Please refer to 7 4 Installing the Solaris Operating System of PRIMEPOWSERHPC2500 2500 1500 900 Installation Guide for the system board number specified to install Solaris Operating System when server is PRIMEPOWSER900 1500 2500 HPC2500 Please refer to B 3 Devalias of PRIMEPOWSERHPC2500 2500 1500 900 Installation Guide for details of Devalias of Administration LAN 31 There are following notes about the Segment ID and System Console ID Segment ID should be 1 When other number are set SCS does not work correctly SMC which can be used in one System Control LAN segment in only one However two SMCs can be used only at the hot spare configuration The SMC should make all servers in the same System Control LAN segment a administration object Two SMCs connected in the same LAN cannot administrate separate servers in the same LAN respectively System Console ID should be 1 However only at the hot spare configuration please set System Console ID to 1 and 2 respectively When other numbers are set SCS does not work correctly 32 In the case of using the Console Connection Unit in duplex composition the following message might be displayed when executing of OS shutdown Console path of Cabinet y SB a in Partition
55. ternal DAT device is needed to back up the SMC settings The scslbackup command should be used to perform this task This command only performs the back up of the SMC settings from hard disk to DAT cassette Please refer to PRIMEPOWER GP7000F System Management Console SMC User s Manual for correct cabling instructions Also refer to the manual supplied with each items of equipment when handling the SMC server platform PCI adapter cards internal devices or any other hardware The SMC can install the following software 1 Solaris 7 Operating System PRIMEPOWER200 only Solaris 8 Operating System Solaris 9 Operating System Solaris 10 Operating System System Console Software Acrobat Reader ver 4 0 or later Netscape Communicator ver 4 5 or later oN 1 KR w Patches For example Recommended Patches issued by Fujitsu or a Fujitsu subsidiary company 9 Plus any application software that the hardware vendor of the PRIMEPOWER GP7000F series recommends For installation of items 1 4 refer to PRIMEPOWER GP7000F System Management Console SMC User s Manual For items 5 and 6 refer to the notes supplied with the software Software required to support the use of the SMC is included Make sure that the Enhanced Support Facility is not installed The use of the Enhanced Support Facility with the SMC will mean the SMC cannot function correctly as the PRIMEPOWER800 1000 2000 900 1500 2500 HPC2500 or GP7000F Model 1
56. the RC2000 console window e The CPU operating ratio reaches 100 under a certain condition e Unable to start console window from the RC2000 2 SMC assistance FJSVscsl e The SCS window environment does not appear when logging in the SMC without the locale C or ja e The configuration display window and the partition window in RC2000 are not shown if etc ethers file includes one or more comment s 3 Partition installer FJSVclis e If two or more identical hostnames different IP addresses are included in etc hosts file the partition installer fails with a syntax error e The partition installer loops if etc default init file includes certain comments e The partition installer cannot select the timezone without the SMC s default timezone 4 Automatic Power Control FJSVapcs e The Automatic Power Control does not set schedules in the locale except C or ja e No error is reported though the Automatic Power Control sets schedule when cron daemon is not active 5 Machine Administration FJSVcsl e When a miss operation happens in the System Control Facility board replacement any error messages do not appear and the next menu displays as if correct operation occurred e The memory slot on the System Board displays incorrect information in the hardware configuration display e It takes a long time to change the console connection unit s subnets of the System Control LAN C120 E091 25ENZ2 B 26
57. u and Hot system board replacement menu Improvement of log collection function C120 E091 25ENZ2 B 20 52 SCS 1 6 1 is composed of SCS 1 6 and additional patch SCS 1 6 1 has following new features 911310 01 FJSVcsl e HCP revision display command support e Improvement of log collection function SCS1 6 1 PRIMEPOWER 100 SMC support 2 Solaris 8 4 01 support on SMC 3 Operation improvement of the Machine Administration Menu 4 Operation improvement of the partition_setup command 5 The following bugs are fixed in SCS 1 6 SMC Assistance FJSVscsl e The message when the time of SMC is later for the time of the partition with the NTP server started is corrected RC2000 FJSVrcon e The error message when the connection to Console Connection Units fails is corrected Partition Installer FJSVclis e The trouble that the restoration of FJSVclis terminates abnormally when the scslrestore command is executed for bringing in a spare system console The patches for SCS1 6 and the packages of SCS are included in SCS1 6 The content added with the patch of SCS1 6 is as follows 911238 01 FJSVmand e The trouble that the composition display of System Management Console might fail is corrected SCS1 5 3 The patches for SCS1 5 2 or SCS1 5 SCS1 5 1 and the packages of SCS are included in SCS1 5 3 SCS1 5 3 has included the patch of SCS1 5 2 The content added with the patch of SCS1 5 3 is as follows 910852 05 FJSVcsl
58. ystem Management Console the mount may fail with the following message Message nfs mount mount XXXX Stale NFS file handle XXXX indicates a mount point Resolution From the side of partition specify NFS version 2 to perform the mount Please see below mount F nfs o ro vers 2 XX cdrom YY ZZ XX The hostname or IP address of System Management Console YY The name of CD ROM ZZ The mount point 44 During a temporary boot Gf the temporary boot is omitted during a network installation that is performed when Solaris 10 OS 8 07 is installed on partition by using partition installer an inquiry about NFSv4 domain occurs So please be sure to apply the following patch after installing System Console Software Patch No 914623 01 FJSVclis or newer Procedure to apply patch 1 Log in to System Management Console as root and please follow the steps below to stop your system and reboot it in single user mode cd usr sbin shutdown y i0 g0 ok boots 2 Patch 914623 01 is applied The following describes the procedure for applying the patch In this case the patch is placed under var tmp on a target machine cd var tmp zcat 914623 01 tar Z tar xvf patchadd 914623 01 3 Please execute the following command after installing the patch and reboot your system usr sbin shutdown y i6 g0 C120 E091 25ENZ2 B

Download Pdf Manuals

image

Related Search

Related Contents

Alaris Ivac 7130 Signature Gold Single Channel Infusion Pump Flow Sensor 4.54 - alaris_carefusion_7100_users  020-101153-01-ESP_LIT MAN USR MASTERSuite 5.3.book  ASUS M32BC 9584 User's Manual  LD HP800PRO - imperiumAUDIO.pl    504409 – LogiLink PA0025 Mode d`emploi en Français  Panasonic CF-VCBAX11EA battery charger    HERMA Security labels A4 45.7x21.2 mm white extra strong adhesion film matt 1200 pcs.  ARB® Air Locker™ Locking Differential, Rear Dana 60  