SIMADYN D Digital Control System Processor module

image

Contents

1. 50 Shield Siemens AG Dk Nr 222342 Edition 05 95 SIMADYN D Hardware User Manual Pin Allocation of the PG26 Pin Allocation of the PG26 6 5 Allocation of the Measurement Jacks X10 X15 X10 X11 X12 X13 X14 X15 Reference point Ground for all other measurement jacks Board reset when jumpered to X10 Line voltage L1 L3 0 24 V analog current actual value 10 V Summated pulses slave 0 15 V Summated pulses master 0 15 V All measurement values are digital except the signal on X13 Ri each 2 2kOhm 6 6 Power converter specific signals X200 Pin No _ Signal Pin No Signal 1 Ground 26 Slave Pulse 2 6 2 P5 27 Pulse disable Master 3 Master pulse 1 1 28 Q12 stepping signal 4 Master pulse 1 2 29 Slave frequency fU 5 Master pulse 1 3 30 Reset 6 Master pulse 1 4 31 Pulse disable 7 Master pulse 1 5 32 SYN1 Master 8 Master pulse 1 6 33 SYN1 Slave 9 Master pulse 2 1 34 Fault Master Slave 10 Master pulse 2 2 35 Fault RH rotating field 11 Master pulse 2 3 36 Fault free 12 Master pulse 2 4 37 Summated fault SITOR 13 Master pulse 2 5 38 Master temperature monitor 14 Master pulse 2 6 39 Master fuse monitor 15 Slave pulse 1 1 40 Master fault excit current 16 Slave pulse 1 2 41 Master fault undervoltage 17 Slave pulse 1 3 42 current zero message M or S 18 Slave pulse 1 4 43 Slave L13 19 Slave pulse 1 5 44 Slave L12 20 Slave pulse 1 6 45 Slave temperature monitor 21 Slave pulse 2 1 46 Slave fuse moni
2. 9 GROUND GROUND 10 CURRENT LOOP TRANSMIT T D 11 15V 15 V 12 20 MA SOURCE 1 13 CURRENT LOOP RECEIVE R D 14 CURRENT LOOP RECEIVE R D 15 RECEIVE TRANSMIT CLOCK RT C 16 20 MA SOURCE 2 17 RECEIVE TRANSMIT CLOCK 18 GROUND GROUND 19 CURRENT LOOP TRANSMIT T D 20 DATA TERMINAL READY OUT 21 20 MA DRAIN 2 22 5V 5 V 23 5V 5 V 24 TRANSMIT RECEIVE CLOCK TR C 20 MA DRAIN 1 25 15V 15 V 6 2 Pin Allocation of the External Signals X5 PIN Designation 1 External synchronization voltage 2 Reference voltage to pin 1 3 P15 Output 15 V 4 External pulse disable connected via switch to pin 3 jumpered pulses enabled open or OV pulses disabled Synchronization of the pulse chains connected with further PG s Output voltage H 10V 14 V Output current max H 40 mA Analog current actual value 10 V Ri 2 2kOhm Excitation current setpoint 0 10V Ri 2 2kOhm Ground digital reference voltage Summated pulses as in X 15 0 Display zero indication of synchronization voltage Logic level 15 V Ri 2 2kOhm for H Signal o gt OON D Siemens AG Dk Nr 222342 Edition 05 95 11 SIMADYN D Hardware User Manual Pin Allocation of the PG26 6 3 Pin Allocation of the Binary inputs and outputs X6 PIN Designation Binary input 1 Binary input 2 Binary input 3 Binary input 4 Binary output 1 Binary output 2 Binary output 3 Binary output 4 P ext input Supply voltage for bin
3. S2 V 24 RS 232 for Televideo PC The hybrid module must be installed on the X51 location for the X01 serial interface 6 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Application Notes WARNING ENSURE CORRECT INSTALLATION Commissioning recommendations are to connect the X5 connector with an interface module SE8 All the necessary measuring signals are available at this module Further information for commissioning see 3 The binary inputs and outputs are connected to the interface module SE4 1 or SE8 SE4 1 with an additional LED status display from the X6 connector via a 10 pin ribbon cable The external connections to the installation are also located there see diagram 2a The SITOR sets or SITOR cubicle systems with interface boards SE20 2 are connected for 12 pulse operation according to diagram 2b The trigger set TG12 always synchronizes itself to the master interface X7M current and voltage values are only evaluated here the connector X7S must be connected to the power converter which is lagging by 30 degrees the phase shift between both line systems must be configured at the connector DMS of the TG12 function module The default value is 30 degrees Compensation of any symmetry losses due to a possible cascaded transformer Adjustment permitted between 27 and 33 degrees the current control requires the total output voltage from the cascade circuit as a voltage proportional signal
4. eee ceeeeeeeee teens sesesrrsssrrrrserrrrssnrrnnssre nee 11 6 2 Pin Allocation of the External Signals X5 0 ccceccccieeecee eects cecceeeeeeeceeeeeeeneeeeeeeeee eee 11 6 3 Pin Allocation of the Binary inputs and outputs X6 0 ecceeeeeeeeeeeee eee ceeeteeeeeeetaeeeees 12 6 4 Pin Allocation of the SITOR Interface X7M X7S cccccccccccseeeeseeeeeee ceeeaeeaeeeeseeseeaaaaes 13 6 5 Allocation of the Measurement Jacks X10 X15 cccceeeeeeeeeeeeeee ceeeeeeteaeeeeeetaeeees 14 6 6 Power converter specific signals X200 ccccccceeeeeeeee eeeeeecneeeeseeeeeeeeeneeeees trennet 14 6 7 SwitGhSet UpS S1 94 tise hata hel a a aaa aa ei a a a agin ev aaa 15 7 Mask of the PG26 in the Master Program cccccceeeceeeeeeeee ceeeeeeeeeeeeeeeeeeteeeeeeenee eeeeeaeeeeeeeenes 15 Samy 2 16 811 86 NO Re Ree ee Pe en a RE meee ee 16 Oil BIOCK diagramin ie hints us cece a cca eet la a ies ale totais a sce titer la cbc 16 8 2 Scale drawing and table of the plug CONNECHOM cccceeeeeeeeeeeee ceeeeeeeeeeeeeetentaeeeeees 16 8 3 AllOcation o F Laer A tice E detain Metta hat etet eat T 16 8 4 Scale drawing of the cable for special lengths cceeeeeeetee ceeeeeeeeeeeeeeeeeeteeeetees 16 Or Miscellaneous Avs A Alte ee ht ee eel iota ed aaa ala el iota tall ody 16 10 ECB INSthUCTIONS Ai ccita tant niet heen aa E a E a tn tad 8 tad 18 Siemens AG Dk Nr 222342 Edition 05 95 SIMADYN D Hardware User Manual Warni
5. floor surface d ECB overall b ECB table e ECB chain c ECB shoes f Cubicle ground connection 18 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual ECB instructions Siemens AG Dk Nr 222342 Edition 05 95 19 SIMADYN D Hardware User Manual ECB instructions Drives and Standard Products Motors and Drives Systems Group Postfach 3269 D 91050 Erlangen 20 Edition 05 95 System Based Technology Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual
6. pulses as from X15 synchronization voltage digital after internal smoothing excitation current setpoint Siemens AG Dk Nr 222342 Edition 05 95 5 SIMADYN D Hardware User Manual Board Design 3 Board Design connection for the local bus design for self ventilation CPU 800186 16 MHz RAM 64 K Byte Battery backup from the power supply connector slot for the program memory module MS31 MS4 MS41 MS45 1 serial interface optional V 24 20 mA TTY 4 binary inputs non voltage isolated interrupt controller 24 V 4 binary outputs non voltage isolated 24 V 50mA real time clock resolution 10 MS Battery backup from the power supply 7 segment display for the configured processor number or error code board ID hardware and software monitoring by watchdogs test connectors for logic analyzers or recorders 50 pin SITOR interface with analog output for the excitation current control 12 bit 10V 20mA SITOR interface Slave 50 pin 50 pin diagnostic connector on the sub module for converter specific signals 4 Application Notes The processor board PG26 can be installed in both the wide rack SR1 SR5 and the narrow rack SR2 SR4 It requires two rack slots I The board must never be inserted nor pulled when under power An interface thick film circuit hybrid module must be installed to implement the Hex monitor dialog via the serial interface X01 S1 20 mA TTY for PG 685
7. the function module TGxxx Each SITOR interface has 12 pulse outputs The supply voltage is 24 V 25 20 The output current for chain pulses is 300 mA for a pulse interval of a maximum of 30 degrees Long duration pulses can also be generated instead of the chain pulses The selection is implemented via software at the connector LDP in the function module TGxxx The maximum output current of the pulse driver is halved when the modulation is disabled Remove the resistor R605 when an application requires the secondary pulses to be completely disabled Siemens AG Dk Nr 222342 Edition 05 95 7 SIMADYN D Hardware User Manual Application Notes Supplementary PG26 components a Service Interface Interface hybrid circuit SS1 20 mA 6DD 1688 1AA0 Interface hybrid circuit SS2 V24 6DD 1688 1ABO Cable PM PG685 SC32 20 mA 10m_ 6DD 1688 1DC0 b Binary inputs and outputs Cable 10 pin 2 0m SC7 6DD 1684 0AHO Terminal block SE4 1 6DD 1681 0AE1 8 binary inputs or outputs non isolated LED display SE8 6DD 1681 0AJO 8 binary inputs or outputs non isolated c SITOR interface Ribbon cable 50 pin no longer supplied by the SWE because of the high female male sensitivity to interference Can be utilized over short distances inside a cubicle without interference sources Customer manufacture aus SM4 SM4 1 and ribbon cable according to SN54234 see 4656849000 11MB Utilization is solely the customers responsibili
8. 4 x 220 mm 2 2 3 SPS 2 Slot 40 28 mm 0 8 kg 5 VDC 2 8 A with MS4 15 VDC 110mA 15VDC 60mA Vbatt 10 uA in backup operation 4 not voltage isolated 24 V Rated value 1 Vto 6 V or Binary inputs open 13 V to 33 V Typ 3 mA 200 us Input filter 4 not voltage isolated 24 VDC 3 6 VDC 20 to 30 V incl harmonics 35 V smaller than 0 5 sec OUTPUT CURRENT AT 1 SIGNAL RATED VALUE SHORT CIRCUIT PROTECT INDUCTIVE LIMIT TRIPPING VOLTAGE RESIDUAL CURRENT SIGNAL LEVEL AT 0 SIGNAL AT 1 SIGNAL Switching delay 50 mA electronic to Up 1V 20 uA at 0 Signal max 3V min supply 2 5V 15 us EXTERNAL SYNCHRONIZATION VOLTAGE RATED VALUE PERM RANGE LOADING ANALOG OUTPUT RANGE ACCURACY RESOLUTION OUTPUT CURRENT 15 V eff 10 to 20 V eff 20 kOhm input impedance Differential input 0 10V 10 bit 12 bit 20 mA protected against short circuit Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Edition 05 95 9 Technical Specification 10 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Pin Allocation of the PG26 6 Pin Allocation of the PG26 6 1 Pin Allocation of the Serial Interface X01 PIN V 24 20 mA TTY 1 FRAME GROUND FRAME GROUND 2 TRANSMIT DATA OUT T D 3 RECEIVE DATA IN R D 4 REQUEST TO SEND OUT RTS 5 CLEAR TO SEND CTS 6 DATA SET READY IN 7 GROUND 8 DATA CARRIER DETECT IN DCD
9. 9005 00 AO 8 4 Scale drawing of the cable for special lengths Scale drawing with order numbers for manufacturing cables with special lengths 3GE 465 684 9000 11 MB 9 Miscellaneous 16 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Miscellaneous Siemens AG Dk Nr 222342 Edition 05 95 17 SIMADYN D Hardware User Manual ECB instructions 10 ECB instructions Components which can be destroyed by electrostatic discharge ECB Generally electronic boards should only be touched when absolutely necessary The human body must be electrically discharged before touching an electronic board This can be simply done by touching a conductive grounded object directly beforehand e g bare metal cubicle components socket outlet protective conductor contact Boards must not come into contact with highly insulating materials e g plastic foils insulated desktops articles of clothing manufactured from man made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive packing material e g conductive foam rubber or household aluminum foil The necessary ECB protective measures are clearly shown in the following diagram a Conductive
10. G Dk Nr 222342 Edition 05 95 1 SIMADYN D Hardware User Manual Warning information Definitions QUALIFIED PERSONNEL For the purpose of this User Manual and product labels a Qualified person is someone who is familiar with the installation mounting start up and operation of the equipment and the hazards involved He or she must have the following qualifications 1 Trained and authorized to energize de energize clear ground and tag circuits and equipment inaccordance with established safety procedures 2 Trained in the proper care and use of protective equipment in accordance with established safety procedures 3 Trained in rendering first aid DANGER For the purpose of this User Manual and product labels Danger indicates death severe personal injury and or substantial property damage will result if proper precautions are not taken WARNING For the purpose of this User Manual and product labels Warning indicates death severe personal injury or property damage can result if proper precautions are not taken CAUTION For the purpose of this User Manual and product labels Caution indicates that minor personal injury or material damage can result if proper precautions are not taken NOTE For the purpose of this User Manual Note indicates information about the product or the respective part of the User Manual which is essential to highlight CAUTION This board contains components whic
11. G12 generates a signal for the correct pulse assignment of the 30 degree lagging power converter system slave The board can be programmed for both the user software and the system firmware operating system monitor program as well as the function module code on plug in memory sub modules MSx located in the X50 connector The user code runs on the processor under the SIMADYN D real time operating system This guarantees interrupt controlled cycle times of gt 1ms dependent upon the configuration Four binary inputs and four binary outputs are available for fast data exchange with other processor modules or for messages from to the installation plug connector X6 The binary inputs can also be declared as interrupt inputs via the software All four binary inputs can be declared as interrupt inputs by the software The processor interrupts cyclic processing at the occurrence of an interrupt at one of these inputs and starts the interrupt function packet Process Interrupt Job PIJ processing The serial interface connector X01 is designed purely as a service interface No communication can be configured via this interface A dialog is only possible with the Hex monitor and only with the corresponding hybrid board installed The seven segment display H1 on the board front plate shows the configured processor number in normal operation The display flashes an error code see 2 when a fault occurs on the board The Hex monitor can be activ
12. SIMADYN D User Manual Digital Control System Processor module PG26 Edition 05 95 DK Nr 222342 User Manual Processor module PG26 Processor module PG26 06 93 fe A a Copying of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utility model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are thankful for any recommendations or suggestions Contents Contents Wea rningsintOrmationc sticeticicie s a tecctin iaer Ta a e a aaa a aa E a a ih te 1 1 Order number Validity Definition 2 0 0 eee ceeccceeeceeee cecceeeeeeeeeeceeeeeeaeeeeeeeees taea eE a a ean akin Kiik 3 2 Functional De SOPO a a a a aa a aa Er ty hae ae a Aa e a a AA AE a E E 3 3 Board Design isa S a aa e aa a a a a a a 6 4 Application NoteSri riii i a Ea a aee aa a a EE Rieter te 6 5 Technical Specification se a a a a A aae a a a E a 9 6 Pin Allocation of the PGZ 07nn iane eect A E a aa a iie 11 6 1 Pin Allocation of the Serial Interface X01
13. ary outputs max 30 V M ext input OOANDARWND 4 O 12 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual 6 4 Pin Allocation of the SITOR Interface X7M X7S The allocation of both interfaces is identical the signals marked with an are not utilized or generated at X7S PIN Designation 1 Shield 2 Shield 3 Fuse monitor fault L 4 Shield 5 Voltage zero L1 L3 6 Shield 7 I actual Frequency 60 30 kHz 21 N 8 Reference voltage excitation current setpoint 9 External M24 ground 10 PULSE 1 6 11 External M24 ground 12 PULSE 1 3 13 Shield 14 External M24 ground 15 PULSE 2 4 16 External M24 ground 17 PULSE 2 1 18 U SYN Synchronization voltage STAR POINT 19 0 message excitation 0 H 20 Temperature monitor fault L 21 Shield 22 U A actual frequency 60 30 kHz U AN 23 Shield 24 I act analog 10 V 1 N not with SE20 2 25 Shield 26 External M24 ground 27 PULSE 1 4 28 External M24 ground 29 PULSE 1 1 30 PULSE 2 2 31 External M24 ground 32 PULSE 2 5 33 External M24 ground 34 U SYN L1 35 Undervoltage monitor fault L 36 Shield 37 zero voltage transgression L1 L2 38 Shield 39 0 Message I 0 H 40 Shield 41 Excitation current setpoint 0 10V 42 PULSE 1 2 43 External M24 ground 44 PULSE 1 5 45 External M24 ground 46 External M24 ground 47 PULSE 2 6 48 External M24 ground 49 PULSE 2 3
14. at X7M The voltage acquisition of the master set when utilizing SITOR sets must be rewired to the total output voltage additional plug connector between the master and the slave see the operating manual SITOR The maximum insulation voltage of the SITOR set must however not be exceeded If several SITOR sets are operated in parallel at X7M and X7S then the connection is implemented via the adapter board C Details are available in the operating manual The maximum output current of the pulse driver must not be exceeded Six pulse operation permits the possibility that both available interfaces X7M and X7S are directly utilized to trigger two SITOR sets connected in parallel This only requires configuring as a six pulse trigger set and closing the switches S2 and S3 on the sub module The pins 3 15V and 4 on the X5 plug connector must be jumpered with a shorting bridge or switch in order to enable the thyristor firing pulses This may be implemented either directly on the X5 plug or through a binary output 24V of a connected interface module A daisy chain bridge can be used to jumper the pins 3 and 4 on X5 Supplying 24V always requires an additional terminal block The synchronization voltage supply may be selected either from an external source via the X5 connector or an internal source from the SITOR set X7M The default setting is the supply via X7M The selection between X7m and X5 is implemented via software at the connector SYX in
15. ated when an error message is being displayed by pressing the S1 key The double test jack X10 and X11 can be used to force a board reset new start This is implemented by jumpering the jacks with a switch or a shorting plug The test jack X10 is also the ground connection for the test signals at X12 X15 A 50 pin test connector X4 is available on the board for hardware diagnostics using a logic analyzer or a recorder The recorder also requires a 10 pin connector X9 Three watchdogs are available for each processor board for monitoring the functionality of the hardware and software Siemens AG Dk Nr 222342 Edition 05 95 3 SIMADYN D Hardware User Manual Functional Description The hardware monitor checks ready signal timeouts during system bus accessing double address decoding errors whether addresses are accessed that are not used system bus fault messages The software monitor checks whether the processor is still running a cyclic program whether the interrupt controller of the serial interfaces timer and inputs are operating correctly A Non Maskable Interrupt NMI is generated when the watchdog detects a fault The processor attempts to eliminate the fault and return to cyclic operation If the fault is being caused by the processor then it switches to an inactive state activates the red dot on the seven segment display and the system fault line on the bus The processor board PG26 has a standard
16. bled when S1 is closed H23 red_ lit for incorrect master slave assignment at X7M X7S Evaluation of both synchronization voltages disabled when S2 is closed The processor board PG26 supplies the trigger pulses for the thyristors of the SITOR set for the torque direction and torque direction II The diode pair H10 and H11 display which torque direction is currently active LED H10 indicates the torque direction I LED H11 indicates the torque direction Il Two further double test jacks X12 X15 are available on the PG26 for the output of converter specific measurement values The reference or ground point is jack X10 X12 phase to phase voltage L1 L3 X13 analog current actual value for the connection of a conventional meter type instrument not available when connected via SE20 X14 Summated pulses Slave X15 Summated pulses Master also at X5 Pin 9 The summated pulse signals indicate the time sequencing of the trigger pulses dependent upon the torque direction In addition the pulse chain sequencing of the primary and secondary pulses for thyristor 1 and the trigger pulses are modulated together see diagram 1 The X5 connector is designed for the supply of external signals and reading measurement signals during commissioning external synchronization voltage external pulse disable synchronization of the pulse chain in conjunction with other PG s analog current actual value as from X12 summated
17. h can be destroyed by electrostati discharge Prior to touching any electronics board your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact WARNING Hazardous voltages are present in this electrical equipment during operation Non observance of the safety instructions can result in severe personal injury or property damage It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed 2 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Order number Validity Definition 1 Order number Validity Definition 6DD 1601 OAFO PG26 Processor board DC 16 Mhz for 12 pulse cascade connections Software version from 3 2 2 Functional Description The processor module PG26 is utilized in the SIMADYN D system for the triggering of 12 pulse line commutated power converters installed as a cascade of two 6 pulse bridges on 30 degree phase shifted power lines The hardware is based on the PG16 board 1 whereby the trigger signals for the second converter are generated on a sub module and can be accessed at a second SITOR interface The high processing power of the 16MHz processor board permits the calculation of the torque shell and therefore the trigger pulse output every 30 degrees The function module T
18. interface for controlling the SITOR thyristor sets The corresponding signals are implemented on a 50 pin connector socket X7M X7S The connector on the mother board X7M always acts as the master The following signals are required from the master converter for the processor board synchronization voltage monitoring signals two signals for the detection of the rotating field direction current zero transgression current actual value as proportional frequency value voltage actual value as proportional frequency value The slave power converter must supply the following signals synchronization voltage monitoring signals two signals for the detection of the rotating field direction 4 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Functional Description The master interface X7M signals are evaluated by the software and generate when faults are detected the messages described in 3 Software checks of the slave interface X7S are not possible The supplementary hardware for the second SITOR interface detects the following faults and displays them using the H20 23 LED s The checks can be disabled with the switches S1 and S2 H20 green lit when no faults have been detected H21 red_ lit as long as a SITOR monitoring fault at X7M or X7S is detected H22 red_ lit when no right hand rotating field is detected at X7S the monitor utilizes the signals L12 L13 from X78 it is disa
19. ng information Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Warning information NOTE The information in this Manual does not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes please contact your local Siemens office Further the contents of this Manual shall not become a part of or modify any prior or existing agreement committment or relationship The sales contract contains the entire obligation of Siemens The warranty contained in the contract between the parties is the sole warranty of Siemens Any statements contained herein do not create new warranties nor modify the existing warranty Warning information WARNING Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to severe bodily injury and material damage can result Only appropriately qualified personnel may work on this equipment or in its vicinity This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual The successful and safe operation of this equipment is dependent on prope handling installation operation and maintenance Siemens A
20. system name MS 2M 0 Message system X6A 4K lt Binary inputs interrupt X7A 1K lt Current actual value SITOR X7B 1K lt EMF SITOR X7E 4K lt Monitor watchdog SITOR X6B 4K gt Binary outputs X7C 1K lt Controller set SITOR X7D 1K lt Command module SITOR X7F 1K lt Analog output SITOR FHEEEFEEEAFEEALEFEFEFEFEFEFEL EEE FEEEFEEEATEPEFEEEEEFEFELEEEFEPEEEEEETEEE EP EF PG26 requires 1 Sub module Siemens AG Dk Nr 222342 Edition 05 95 15 SIMADYN D Hardware User Manual Appendices Allocation of plugs and function modules The SITOR connector can be accessed by the following function modules CONNECTOR SECTION FUNCTION MODULE XGA BII8 Binary input 4 Binary values X6B BIQ8 Binary output 4 Binary values Use of the BII8 module on the PG26 requires paying attention to the fact that the four highest bits can take on undefined values They should be filtered out X7A CAV Current actual value SITOR X7B EMF EMF SITOR X7C Tgxxx Controller stage SITOR X7D SOL Command stage SITOR X7E TGF Watchdog fault detect SITOR X7A FCS Analog output SITOR 8 Appendices 8 1 Block diagram Block diagram 3SE 465 601 9005 00 SU 8 2 Scale drawing and table of the plug connector Scale drawing with view of front panel and table of the implemented plug connector 3SE 465 601 9005 00 MB 8 3 Allocation plan Allocation plan 3SE 465 601
21. tor 22 Slave pulse 2 2 47 Ground 23 Slave pulse 2 3 48 Slave fault undervoltage 24 Slave pulse 2 4 49 Ground 25 Slave pulse 2 5 50 P5 All signals 5V level Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Mask of the PG26 in the Master Program 6 7 Switch set ups S1 S4 1 Right hand rotating field X7S monitor open active jumpered disabled S2 Slave Line lag monitor open active jumpered disabled S3 Pulse sample reset at X7S open _ active for 12 pulse operation jumpered disabled pulses at X7M and X7S identical S4 always open used for internal checks 7 Mask of the PG26 in the Master Program PG26 Processor board Direct Current 1 L Bus PlJ iN 0 Interrupt processing FP SFJ 1N 0 System error FP PRX 1N 0 Special communication FP receive PJ1 1N 1 Permanent processing FP PJ2 1N 0 PJ3 1N 0 PJ4 1N 0 PJ5 1N 0 PJ6 1N 0 PJ7 1N 0 PJ8 1N 0 PTX 1N 0 Special communications FP transmit ILS IK 0 L Bus interrupt transmit TO TG Basic clock rate T1 TS 1 Clkr T0 generated LB conn T2 TS 2 Clkr h T3 TS 3 Clkr y T4 TS 4 Clkr y T5 TS 5 Clkr y 7 TY TX T System FP clock rate SSM 2C 0 Length save area n 1 2 kByte ISE1C N Ignore failed message RDYINT Y N CCT 8R 0 Transmit communication name Tx CCR 8R 0 receive communication name Tx COP 8R 0 Dialog communication name Tx CMS 8N 0 Message system name CTS 8N 0 Transport
22. ty Round cable screened 50 pin 2m SC17 2 6DD 1684 0BH2 female male 50 pin 10m SC31 2 6DD 1684 0DB2 female male These cables consist of screened round cable with twisted pair conductors The screening is improved by using a plug casing at the connectors The SWE works only supplies these prepared cables Special lengths must be manufactured by the customer The cables are made according to the scale drawing 4656849000 11 which also contains all the necessary order numbers The scale drawing is contained in the appendix The maximum permissible distance between the PG26 and the SITOR unit is 50m with this cable Interface boards SE20 2 6DD 1681 0CA2 Adapter board C 6QX 5340 8 Edition 05 95 Siemens AG Dk Nr 222342 SIMADYN D Hardware User Manual Technical Specification 5 Technical Specification General Data INSULATION GROUP AMBIENT TEMPERATURE STORAGE TEMPERATURE HUMIDITY CLASS ALTITUDE RATING MECHANICAL STRESS PACKAGING SYSTEM DIMENSIONS BOARD WIDTH WEIGHT CURRENT CONSUMPTION BINARY INPUTS NUMBER INPUT VOLTAGE INPUT VOLTAGE FOR 0 SIGNAL FOR 1 SIGNAL INPUT CURRENT AT 1 SIGNAL DELAY TIME BINARY OUTPUTS NUMBER SUPPLY VOLTAGE RATED VALUE HARMONICS PERM RANGE TRANSIENTS A to VDE 0110 power side paragraph 13 group 2 at 24 VDC 15VDC 5 VDC 0 to 55 degC 40 to 70 degC F to DIN 40040 S to DIN 40040 Installation in fixed vibration resistant devices ES 902 C 233