Home
User Manual - Galco Industrial Electronics
Contents
1. C1XP Series Models C1XP01 115AC C1XP03 115AC C1XP03 D240AC C L LI JJ gt Z gt r Minarik DRIVE S amp S Copyright 2013 by Minarik Drives All rights reserved No part of this document may be reproduced or transmitted in any form without written permission from Minarik Drives The information and technical data in this document are subject to change without notice Minarik Drives makes no warranty of any kind with respect to this material including but not limited to the implied warranties of its merchantability and fitness for a given purpose Minarik Drives assumes no responsibility for any errors that may appear in this document and makes no commitment to update or to keep current the information in this document Printed in the United States of America Safety Warnings Have a qualified electrical maintenance technician install adjust and service this equipment Follow the National Electrical Code and all other applicable electrical and safety codes including the provisions of the Occupational Safety and Health Act OSHA when installing equipment Reduce the chance of an electrical fire shock or explosion by proper grounding over current protection thermal protection and enclosure Follow sound maintenance procedures It is possible for a drive to run at full speed as a result of a component failure Install a master switch in the AC line for stopping the drive in an emergen
2. T IR COMP CURR LIMIT IR COMP 1 15 HP 90 VDC 1800 RPM 0 75 ADC 1 20 HP 90 VDC 1750 RPM 0 56 ADC 1 25 HP 90 VDC 1800 RPM 0 47 ADC CURR LIMIT IR COMP CURR LIMIT IR COMP CURR LIMIT IR COMP Figure 5 Typical C1XP01 CURR LIMIT and IR COMP Settings CURR LIMIT IR COMP CURR LIMIT IR COMP CURR LIMIT IR COMP 1 4 HP 130 VDC 2500 RPM 1 80 ADC 1 8 HP 130 VDC 2500 RPM 1 00 ADC 1 12 HP 130 VDC 2500 RPM 0 71 ADC CURR LIMIT IR COMP CURR LIMIT IR COMP CURR LIMIT IR COMP Figure 6 Typical C1XP03 CURR LIMIT and IR COMP Settings 1 40 HP 90 VDC 1800 RPM 0 24 ADC 1 50 HP 90 VDC 1750 RPM 0 24 ADC 1 100 HP 90 VDC 1750 RPM 70 mADC 1 8 HP 90 VDC 1750 RPM 1 30 ADC 1 10 HP 90 VDC 1725 RPM 1 10 ADC 1 20 HP 90 VDC 1750 RPM 0 56 ADC 15 16 Troubleshooting Warning Dangerous voltages exist on the drive when it is powered When possible disconnect the AC line voltage from the drive while troubleshooting Be alert High voltages can cause serious or fatal injury Before troubleshooting Perform the following steps before starting any procedure in this section e Disconnect AC line voltage from the drive e Check the drive closely for damaged components e Check that no conductive or other foreign material has become lodged on the printed circuit board e Verify that every connection is correct and in good condition e Verify th
3. at there are no short circuits or grounded connections e Check that the drive s rated armature outputs are consistent with the motor ratings Troubleshooting 17 Problem Line fuse blows Possible Causes 1 Line fuses are the wrong size 2 Motor cable or armature is shorted to ground 3 Nuisance tripping caused by a combination of ambient conditions and high current spikes 4 Field circuit is open Suggested Solutions 1 Check that line fuses are 6A 2 Check motor cable and armature for shorts 3 Increase CURR LIMIT setting 4 Send in drive to Minarik repair department Line fuse does not blow but the motor does not run 1 Speed adjust potentiometer is set to zero speed 2 Speed adjust potentiometer connections are open 3 Drive is in current limit 4 Drive is not receiving AC line voltage 5 Motor is not connected 1 Increase speed adjust potentiometer setting 2 Check that the speed adjust potentiometer connections are not open 3 Verify that the motor is not jammed Increase CURR LIMIT setting 4 Apply AC line voltage to L1 and L2 5 Connect motor to A1 and A2 18 Troubleshooting Problem Motor runs too fast at maximum speed setting Possible Causes MIN SPD and MAX SPD settings are too high Suggested Solutions Recalibrate MIN SPD and MAX SPD Motor runs too slow or too fast MIN SPD and MAX SPD ar
4. cy This drive is not isolated from earth ground Circuit potentials are at 115 VAC or 230 VAC above earth ground Avoid direct contact with the printed circuit board or with circuit elements to prevent the risk of serious injury or fatality Use a non metallic screwdriver for adjusting the calibration trimpots X X SHOCK AVOID KEEP AVOID HAZARD HEAT DRY VIBRATION Contents Specifications Dimensions Installation Mounting ee ore cou Heatsinking Line fusing Connections Operation Before applying power SAUD ere Line starting and line stopping Calibration SPD MIN SPD 2020808 4 En CURR LIMIT aieo eue nre tota etes ee Troubleshooting Block Diagrams Unconditional Warranty RO N 18 inside back cover Specifications Maximum Horsepower Horsepower AC Armature Armature Range Range Line Current Voltage w 120 VAC w 240 VAC Model Voltage Amps DC Range Applied Applied C1XP01 115AC A 120 1 0 0 130 1 100 1 10 N A C1XP03 115AC A 120 3 0 0 130 1 10 1 4 N A AC line voltage tolerance is 10 single phase 50 60 Hz Form Factor 1 05 at base speed Acceleration Time no load 1 second Deceleration Time no load 1 second Speed Regulation of base speed 1 Line Fuse 5A fast acting Weigh
5. d full CW It is factory set for 90 VDC full load voltage To calibrate MAX trimpot setting 1 Set the MAX trimpot full CCW 2 Turn the speed adjust potentiometer full CW 3 Adjust the MAX SPD trimpot until the desired maximum motor speed is reached MIN MINIMUM SPEED The MIN trimpot setting determines the motor speed when the speed adjust potentiometer is turned full CCW It is factory set to zero speed To calibrate MIN trimpot setting 1 Turn the speed adjust potentiometer full CCW 2 Adjust the MIN trimpot until the motor has stopped or is running at the desired minimum speed Note Check the MIN and MAX trimpot setting after recalibrating to verify that the motor runs at the desired minimum and maximum speed Calibration 13 CURR LIMIT The CURR LIMIT trimpot setting determines the maximum armature current output of the drive It is factory calibrated to 1 ADC for CI XPOI drives and 3 ADC for C1 XP03 drives To calibrate CURR LIMIT L With the power disconnected from the drive connect a DC ammeter in series with the armature Set the CURR LIMIT trimpot to minimum full CCW Connect power to the drive Push the speed adjust potentiometer knob to turn the power on The motor should remain stopped Lock the motor shaft Be sure that the motor is firmly mounted Set the speed adjust potentiometer to maximum full CW Adjust the CURR LIMIT trimpot CW slowly until the a
6. e not calibrated Calibrate MIN SPD and MAX SPD Motor will not reach the desired speed 1 MAX SPD setting is too low 2 IR COMP setting is too low 3 Motor is overloaded 1 Increase MAX SPD setting 2 Increase IR COMP setting 3 Check motor load Resize the motor if necessary Motor pulsates or surges under load 1 IR COMP 1 set too high 2 Motor bouncing in and out of current limit 1 Adjust the IR COMP setting slightly CCW until the motor speed stabilizes 2 Make sure motor is not undersized for load adjust CURR LIMIT setting For additional assistance contact your local Minarik Drives distributor or the factory direct at 1 800 MINARIK 19 Functional Diagrams dXL9 Z YOLV 10934 ADVLIOA 21 LIAN 1N344N9 LINOMIO OST 21 4 IMO d L Z1 LINIHII dWO9 dl CV 40151534 109819 LIN9819 yowadaa4 ONIHOLIMS d33dS NIN XV LV 20 Functional Diagrams 12V 5V 65 2K R30 30K P504 SPEED 10K ADJUST POTENTIOMETER CW R15 15K R24 300K C501 220 25 MMBZ5242B 1 22 35 Figure 9 C1XP Input Circuit Notes 22 Notes Unconditional Warranty A Warranty Minarik Drives warrants that its products will be free from defects in workmanship and material for twelve 12 months or 3 000 h
7. elding guidelines As a general rule Minarik Drives recommends shielding of all conductors if 1 wire lengths exceed 18 inches with separation of power and logic leads 2 wire lengths exceed 4 inches and power and logic leads must be bundled together 3 radiated and or conducted noise must be minimized due to concerns about immunity or general compliance CE FCC etc Minarik Drives considers this an unfavorable condition and does not recommend bundling of power and logic leads for any length AN If it is not practical to shield power conductors Minarik Drives recommends shielding all logic level leads If shielding is not practical the user should twist all logic leads with themselves to minimize induced noise 6 Installation AN 4 Under no circumstances should power and logic leads be bundled together Induced voltage can cause unpredicatable behavior any electronic device including motor controls It may be necessary to earth ground the shielded cable If noise is produced by devices other than the drive ground the shield at the drive end If noise is generated by a device on the drive ground the shield at the end away from the drive Do not ground both ends of the shield If the drive continues to pick up noise after grounding the shield it may be necessary to add AC line filtering devices or to mount the drive in a less noisy environment Heat sinking series drives have sufficient heat sin
8. iometer knob CW to turn the power on an audible click will be heard The POWER ON LED lights when the power is on 2 Rotate the speed adjust potentiometer knob clockwise until the desired speed is reached 3 Turn the speed adjust potentiometer knob full CCW to turn the power off an audible click will be heard The POWER ON LED is extinguished when the power 1s off 10 Operation Line starting and line stopping When AC line voltage is applied to the drive the motor accelerates to the set speed When AC line voltage is removed the motor coasts to a stop Line starting and line stopping applying and removing AC line voltage is recommended for starting and stopping in emergency situations only It is not recommended for frequent starting and stopping 11 Calibration Series drives have four user adjustable trimpots MAX MIN CURR LIMIT and IR COMP Recalibrate the trimpots if a different horsepower motor is used All trimpot settings increase with clockwise CW rotation and decrease with counterclockwise CCW rotation Use a non metallic screwdriver for calibration Each trimpot is identified on the printed circuit board MAXIMUM SPEED IR Z D FUS01 P RD P501 P502 C CURRENT Figure 4 Calibration Trimpot Layout 12 Calibration MAX MAXIMUM SPEED The MAX trimpot setting determines the motor speed when the speed adjust potentiometer is turne
9. king in their basic configurations No additional heat sinking is required Line fusing C1XP series drives come with two preinstalled fuses Use fast acting AC line fuses rated for 250 volts and approximately 150 to 200 of the maximum armature current Installation Warning This product does not have internal solid state motor overload protection It does not contain speed sensitive overload protection thermal memory retention or provisions to receive and act upon signals from remote devices for over temperature protection If motor overload protection is needed in the end use product it needs to be provided by additional equipment in accordance with NEC standards 8 Installation Connections ASSUMPTIONS Minarik Drives s drives supply motor voltage to terminals Al and A2 1 15 positive with respect to A2 It is assumed throughout this manual that the driven motor will rotate clockwise CW while looking at the output shaft protruding from the front of the motor If the opposite is desired simply reverse the wiring of Al and A2 with each other USO ir ium m EBENE ABC Le 230Le 115 VAC MOTOR ARMATURE 230 VAC Figure 2 C1XP Connections Operation Before applying power Verify that no conductive material is present on the printed circuit board Verify that the AC supply is properly balanced Startup To start the drive 1 Turn the speed adjust potent
10. ours whichever comes first from date of manufacture thereof Within this warranty period Minarik Drives will repair or replace at its sole discretion such products that are returned to Minarik Drives 14300 De La Tour Drive South Beloit IL 61080 USA This warranty applies only to standard catalog products and does not apply to specials Any returns for special controls will be evaluated on a case by case basis Minarik Drives is not responsible for removal installation or any other incidental expenses incurred in shipping the products to and from the repair point B Disclaimer The provisions of Paragraph A are Minarik Drives s sole oblication and exlude all other warranties of merchantability for use express or implied Minarik Drives further disclaims any responsibility whatsoever to the customer or to any other person for injury to the person or damage or loss of property of value caused by any product that has been subject to misuse negligence or accident or misapplied or modified by unauthorized persons or improperly installed C Limitations of Liability In the event of any claim or breach of any of Minarik Drives s obligations whether express or implied and particularly of any other claim or breach of warranty contained in Paragraph A or of any other warranties express or implied or claim of liability that might despite Paragraph B be decided against Minarik Drives by lawful authority Minarik Drives shall under no circ
11. rmature current is 120 of motor rated armature current Set the speed adjust potentiometer to minimum and remove the stall from the motor A Warning Although the CURRENT LIMIT trimpot can be set to exceed the motor s maximum armature current rating we recommend you do not run the motor continuously beyond that rating Continuous operation beyond the maximum armature current rating may cause thermal degradation of the motor and drive 14 Calibration IR COMP The IR COMP trimpot setting determines the degree to which motor speed is held constant as the motor load changes It is factory set for optimum motor regulation To calibrate IR COMP exact calibration 1 Turn the IR COMP trimpot full CCW 2 Set the speed adjust potentiometer until the motor runs at midspeed without load for example 900 RPM for an 1800 RPM motor A hand held tachometer may be used to measure motor speed 3 Load the motor armature to its full load armature current rating The motor should slow down 4 While keeping the load on the motor rotate the IR COMP trimpot until the motor runs at the speed measured in step 2 Approximate calibration If the motor does not maintain set speed as the load changes gradually rotate the IR COMP trimpot CW If the motor oscillates overcompensation the IR COMP trimpot may be set too high CW Turn the IR COMP trimpot CCW to stabilize the motor speed Calibration CURR LIMIT IR COMP CURR LIMI
12. t 0 68 Ib Dimensions 5 50 in x 3 50 in x 3 20 in Ambient Temperature Range 10 C 40 C Dimensions POWER ON 5 50 140 1 1 NN 3 20 81 e e 0 88 22 la 2 28 58 3 42 87 3 51 89 Figure 1 C1XP Dimensions Dimensions Figure 1 C1XP Dimensions continued Installation A x X Age SHOCK AVOID KEEP AVOID HAZARD HEAT DRY VIBRATION Mounting Drive components are sensitive to electrostatic fields Avoid direct contact with the circuit board Protect the drive from dirt moisture and accidental contact Mount the drive away from other heat sources Operate the drive within the specified ambient operating temperature range Prevent loose connections by avoiding excessive vibration of the drive Mount C1 XP drives vertically or horizontally using the two mounting keyholes on the back of the case Figure 2 The keyholes are 2 5 inches apart For access to the keyholes from the inside of the case remove the four case cover screws lift the case cover straight out and remove the fishpaper from inside the back cover Leave the case cover removed to wire the AC line and motor to the drive After mounting remember to return the fishpaper to the inside back cover as it provides necessary electrical isolation Installation 5 Wiring Use 16 AWG wire for motor and AC line voltage wiring Shi
13. umstances be liable for any consequantial damages losses or expense arising in connection with the use of or inability to use Minarik Drives product for any purpose whatsoever An adjustment made under warranty does not void the warranty nor does it imply an extension of the original 12 month warranty period Products serviced and or parts replaced on a no charge basis during the warranty period carry the unexpired portion of the original warranty only If for any reason any of the foregoing provisions shall be ineffective Minarik Drives s liability for damages arising out of its manufacture or sale of equipment or use thereof whether such liability is based on warranty contract negligence stict liability in tort or otherwise shall not in any event exceed the full purchase price of such equipment Any action against Minarik Drives based upon any liability or obligation arising hereunder or under any lap applicable to the sale of equipment or the use thereof must be commenced within one ear after the cause of such action arises MINARIK DRIVES www minarikdrives com 14300 De La Tour Drive South Beloit IL 61080 Phone 800 MINARIK 646 2745 Fax 815 624 6960 Document Number 250 0212 Revision 3 Printed in the U S A August 2013