Home
YH-T6 USER MANUAL
Contents
1. the tare light is on When the system returns to zero point and still has tare weight press Or exit the net weighing mode tare weight returns to zero and tare light is off the system returns to gross weight weighing mode The max accumulative weight is 999999 decimal point excludes 5 Accumulative add accumulative display and accumulative clear operation Load the goods Display accumulative weight for around 2 seconds when it is stable kkk accu light is on The max accumulative weight is press accu 999999 decimal point excludes Display accumulative times for around 2 seconds it t means how many times you have accumulated The max accumulative times are 99 Returns to weighing mode accu light is off mode accumulation operation ends accu light is off 2 Ready to Make indicator return to zero or tare Note the data accumulative add again with 2 bit decimal points is an example Load the goods Display all accumulative weight for around 2 when the number seconds accu light is on is stable t Display accumulative times for around 2 seconds accumulate again x Returns to weighing mode accu light is off Make the indicator return to zero Note the data with 2 bit decimal points is an The indicator retums to TN example Press Display accumulative weight for around 2 seconds accu light is on oe INE Di
2. YH T6 USER MANUAL 1 Function of the keys Switch key It uses to press turn off under weighing mode and press turn on under power off mode Accumulative clear key It uses to exit under calibration mode Kg lb switch key It uses to move flash bit to left side under calibration mode Q Accumulative add key It uses to move flash bit to right side under calibration mode Q Tare key It uses to add the number on the flash bit under calibration mode or switch parameter Zero key It uses to confirm under calibration mode 2 Power on and off 1 Press around 3 seconds it begins to self inspect then it enters to weighing mode power on to pre heat 15 30 minutes If you use rechargeable battery first you also have to power on but remember to charge the battery fully when using the rechargeable battery at the first time 2 After power on if the indicator vibrates from zero point but it is still in auto zero range 10 against full span it will come to zero automatically then zero point light is on If it is out of auto zero range you have to adjust the zero point or re calibrate 3 Press around 3 seconds to exist the weighing mode 3 Zero setting operation If gross weight of the system is in manual zero range 2 against full span press C0 to make the indicator show zero but if it has tare weight the indicator can t be zero 4 Tare operation When gross weight is over zero and the system is stable press to tare
3. eight that loaded to normal range 3 Re set full span for the indicator Err 05 or Indicator doesn t connect Please check the connection between indicator and load the exit of with load cell or indicator cell or let the manufactory repair self inspection A D part is damaged or when power is on load cell doesn t work 1 Please confirm the correctness of actual load weight and Err 11 Calibration load error input 2 Recalibate after adjust the division Indicator internal running Please kindly wait don t do any operation 1 If it s under the mode of 1b please change it back to be ee Display the minus overflow kg display mode of weight 2 Add more goods on the platform 11 Maintenance 1 To guarantee the indicator s cleaning and lifetime the indicator shouldn t be placed directly under sunshine and should be set in the plain space 2 The indicator can t be placed into the place where dust pollution and vibration are serious 3 Load cell should connect with the indicator reliably and the system should be well connected into ground The indicator must be protected from high electrical field and high magnetic field Load cell and indicator should be far away from object has strong causticity flammability and explosive 4 Liquid and conducting particle should not be poured into the indicator otherwise the electronic components will be damaged and electric shock is likely to ha
4. pair The indicator shouldn t be opened randomly otherwise free guarantee will be cancelled
5. ppen 5 You must cut off power supply before pulling out connecting line of load cell 6 Interfaces of the indicator must be strictly connected to load cell as per the figure on the user manual During operation if trouble occurs operator must pull off the power supply plug immediately and user should return this Terminal to our company for repair Non weighing manufacturer should not repair it or by yourself otherwise further destruction may happen 7 Kindly reminder Before using the indicator please test and confirm we are only responsible for the indicator s quality not for the problem of the weighing system 8 The rechargeable battery is not granted to free repair because it is easily exhausted product e In order to prolong the lifetime please fully charge the battery If you won t use the indicator for a long time you should charge the battery every two months and charge 24 28 hours each time NOTE the charge way and charge time mentioned above are for charging through this indicator e Removal or installation must be carefully executed to avoid strong vibration impact and bump in order to protect the rechargeable battery from being damaged 9 From the shipping date the indicator has one year free repair period If any non artificially obstacle about the indicator happens under correct using conditions within this period the user is allowed to send the product with its guarantee card of the correct number back to us for free re
6. splay accumulative times for around 2 seconds accumulative displ ay function aca Return to Return to weighing mode accu light is off mode accu light is off ae peta wetting mode es taht sof all accumulative weights and all weighing Press times 6 Kg Ib switch Under weighing mode press F to switch between kg amp lb NOTE Once it switched all the accumulative weight or times will return to zero 7 Power saving mode When weighing data is stable 3 minutes later it will enter power saving mode the indicator shows andit flashes from left to right 8 Built in rechargeable battery Connect to AC power whether the power is on or off the weighing indicator begins to charge the battery When power is off the charging speed will be faster The charging time is around 24 28 hours It can be used for 36 hours after fully charged typically data 9 Low voltage alarm and cut off When the battery s voltage is lower than around 3 3V the indicator will show bAttLo every 30 seconds to mean the voltage is low and there s sound of moo for reminding Customers shoud charge the battery immediately If continue to use three miniutes later the indiator will switch off automatically to protect the rechargeable battery 10 Information introduction Information Meaning Solution displayed 1 If the indicator has not been calibrated you should do it Err 03 Overload 2 Decrease the w
Download Pdf Manuals
Related Search
Related Contents
Samsung 23,5" UHD 4K Monitor UE850 Bruksanvisning Service Manual Mode d`emploi - FANMux Audiopole Des distances à vol d`oiseau aux distances COBY electronic MP-CD475 Portable Multimedia Player User Manual HP ProLiant DL320 G6 Server Maintenance and Service Guide Atlona AT-VGA88M-SR Printer User Manual 取扱説明書( PDF: 2MB ) Windmere PT-9738D Use & Care Manual Copyright © All rights reserved.