Home
Manual - MTL Instruments Group
Contents
1. input is active Analogue setpoint is active Analogue input is zero mA All LEDs medium Medium speed flash 1 6HZ indicates the module is half way through the flash configuration process Medium flash also happens when you set the rotary switch to position 0 when powering on the unit 4 Antenna installation 1m minimum Collinear antenna Objects e g walls Weatherproof connectors e g 3M 23 tape etc Eu Surge protector arrestor optional Stress relief loop 0 Mast A good ground connection must be provided Ground Stake to the mast unit and surger arrestor protector A The antenna must be be installed above all local obstructions QSG 800LT 1 7 5 May 2010 5 Resetting your unit to factory defaults You must reset the receiver unit to factory defaults before linking the transmitter and receiver units To reset the default factory configuration 1 Set the RSSI rotary switch to position 0 using a screwdriver 2 Power on the WIO 800LT transmitter 3 The WIO 800LT transmitter flashes all LEDs at medium flash i e 1 6 Hz NOTE If the LEDs do not flash you must repeat steps 1 and 2 until the LEDs flash before continuing 4 Set the RSSI rotary switch to another position e g position 1 within 5 seconds 5 Set the RSSI rotary switch to position 0 within another 5 seconds 6 The WIO 800LT transmitter lights all LEDs for 2 seconds before returning to n
2. 30V DC 500mA en For inductive load use surge diodes N Thermocouple type J K or T or mV signal T Loop powered sensor shown 8 External powered sensors are also suitable Dls suitable for volt free contacts or NPN transistor devices POWER SUPPLY 9 30V DC 250mA 12V 125mA 24V IMPORTANT ELECTRICAL SAFETY INFORMATION WARNING In order to comply with Electrical Safety Regulations this module must be installed in an Electrical AND Fire enclosure This enclosure may be a single or multiple enclosures Access to the module is to be made by a Service Person only QSG 800LT 1 7 3 May 2010 The front panel provides the following components SMA antenna connector at top of unit WIO 800LR gt OK iiu D2 RS232 configuration port Setpoint rotary switch The triangle on the rotary switch indicates the current position for example Position O or Position 3 NOTE To avoid damaging the rotary switch use a screwdriver to change the position The rotary switch uses the following setpoint levels The LEDs on the front panel indicate the unit status LED Status indicates N No power supply OK Red Fault condition detected in unit TX Flashes Transmitting Message OKGren Current status of the unit OK QSG 800LT 1 7 May 2010 PGON Configuration Cable Connected LED Status indicates INPUTS ON The Input LEDS D1 D2 SP AZ light when the corresponding
3. 3484 6795 Fax 82 2 3484 6778 MTL Instruments BV MTL Instruments BV Terheijdenseweg 465 4825BK Breda The Netherlands Tel 31 0 76 7505360 Fax 31 0 76 7505370 E mail info mtlbenelux com Cooper Crouse Hinds Pte Ltd No 2 Serangoon North Avenue 5 06 01 Fu Yu Building Singapore 554911 Tel 65 6 487 7887 Fax 65 6 487 7997 E mail sales mtlsing com sg MIL Instruments Villa No 4 Sector 2 17 Street 6 PO Box 53234 Abu Dhabi UAE Tel 971 2 446 6840 Fax 971 2 446 6841 E mail mtlgulf mtlinst com Measurement Technology Limited Great Marlings Butterfield Luton Beds England LU2 8DL Tel 44 0 1582 723633 Fax 44 0 1582 422283 E mail enquiry mtl inst com Cooper Crouse Hinds MTL Inc 3413 N Sam Houston Parkway W Suite 210 Houston TX 77086 USA Tel 1 281 571 8065 Fax 1 281 571 8069 E mail csinfo mtl inst com
4. 7 May 2010 7 Safety information Thank you for selecting the WIO 800LT transmitter for your telemetry needs We trust it will give you many years of valuable service To ensure your WIO 800LT transmitter enjoys a long life double check ALL your connections with the user s manual before powering on the unit WARNING Incorrect termination of supply wires may cause internal damage and will void warranty 8 Unit specifications Digital inputs Dry contact digital inputs slow pulsed at 10Hz All inputs are suitable for voltage free contacts e g mechanical switches or NPN transistor devices e g electronic proximity switches NOTE PNP transistor device inputs are NOT suitable Analog inputs 0 20mA differential input 16 bit resolution 0 196 accuracy 10 ohm input impedance Thermocouple J K or T type thermocouple with on board inputs cold junction compensation Cold junction compensation accuracy x1 over ambient temp range 40 to 60 C Power supply 9 30 VDC 1 Amp CSA certified Class 2 power supply For use in Class I Div 2 hazardous areas the power supply must be approved for Class Div 2 use WARNING Explosion hazard do not connect or disconnect while circuit is live unless area is known to be non hazardous Transmitter 1 5 mW or 500 mW DFSK Fixed Frequency Transmitter Frequency 868 525 MHz 500 mW 5km out of plant 1km obstructed environment 869 875MHz 5 mW 1km out of plant 300m obstructed environ
5. WIO 800LT wireless I O transmitter unit Quick Start Guide QSG 800LT ABOUT THIS DOCUMENT This is the Quick Start Guide for the MTL WIO 800LT Wireless I O Transmitter Unit and contains the T sections Section Read this section if youwantto this section if you want to Basic steps for Learn the basic steps for REA and using jene ees Factory default Understand how the transmitter sends DEC CNN orton tan s DIT MU on T IM Resetting factory Reset your unit to the original factory default defaults settings 16 Linking Tx and Rx units Link your units to work as a dedicated pair Understand important safety information related to your unit NOTE You must read this information before installing your unit 8 Specifications See the technical information For more information see the following sections 7 Safety information 1 Basic steps for using your unit This document describes how to configure your unit using the default factory configuration that lets you easily setup your network as a simple send receive network using a dedicated pair of transmitter and receiver units The basic steps for using your unit are 1 Connect the antenna power supply and transducer signals using the instructions in this document Power supply and transducer connection is described in the section Unit components and connections Antenna connection is described in the section Antenna installation For more informa
6. ment MTL Instruments Pty Limited 9 12 Billabong Street Stafford Queensland 4053 Australia Tel 61 1300 308 374 Fax 61 1300 308 463 E mail enquiries mtlaus com au Cooper Electric Shanghai Co Ltd Room 2001 China Life Tower 16 Chao Yang Men Wai Street Chao Yang District Beijing China 100020 Tel 86 10 5980 0288 Fax 86 10 8562 5725 E mail bjsales mtl inst cn MTL Instruments sarl Les Carr s du Parc 10 rue des Rosi ristes 69410 Champagne au Mont d Or France Tel 33 0 4 78 64 98 32 Fax 33 0 4 78 35 79 41 E mail infoGmtl inst fr MTL Instruments GmbH An der G mpgesbr cke 17 D 41564 Kaarst German Tel 49 0 2131 718930 Fax 49 0 2131 7189333 E mail info mtl de MTL India No 36 Nehru Street Off Old Mahabalipuram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail sales mtlindia com MTL Italia srl Via Cantt 11 20092 Cinisello Balsamo MI Italy Tel 39 0 2 61802011 Fax 39 0 2 61294560 E mail info mtl inst it Group Internet home page http www mtl inst com Members of The MTL Instruments Group Cooper Crouse Hinds Japan KK MT Building 3F 2 7 5 Shiba Daimon Minato ku Tokyo Japan 105 0012 Tel 81 0 3 6430 3128 Fax 81 0 3 6430 3129 E mail sales mtlkk co jp Cooper Crouse Hinds Korea 12F Vision Tower 707 2 Yeoksam dong Gangnam gu Seoul 135 080 South Korea Tel 82 2
7. ormal operation NOTE If the LEDs do not light you must repeat the process from step 1 until the LEDs light before continuing 7 You can now link the transmitter and receiver units 6 Linking your transmitter and receiver units You must reset the transmitter unit to factory defaults to disable encryption before linking the transmitter and receiver units For more information see the previous section NOTE You must complete the linking process in 60 seconds To link the transmitter and receiver units 1 Press and hold down the RSSI Pushbutton on the receiver 2 Power on the receiver while holding down the RSSI Pushbutton 3 Release the RSSI Pushbutton as soon as the Receiver LEDS flash within 5 seconds of powering the receiver 4 The receiver will flash all LEDs for a maximum 60 seconds while it tries to link to the transmitter 5 Power on the transmitter The transmitter sends a special Link message to allow the receiver to recognise the transmitter 6 When the units link the receiver lights all LEDs for 2 seconds before returning to normal operation NOTE If the receiver LEDs continue flashing within the 60 seconds the units are not linked and you should retry the linking process by powering the transmitter off and on again If you exceed the 60 seconds you must restart the linking process from step 1 You can now bench test your configuration before deploying QSG 800LT 1 7 May 2010 QSG 800LT 1
8. tion see the WIO 800L Installation Manual 2 Reset the transmitter and receiver units to the factory default configurations 3 Link the transmitter and receiver units to work as a dedicated pair 4 Bench test your configuration before deploying NOTE You can also configure your network using a user defined customised configuration that lets you set specific information about your network For more information on setting a user defined customised configuration see the WIO 800L User Manual on the enclosed CD 2 Factory default configuration When you configure the units using the configuration in this document the inputs from the transmitter are sent to the outputs at the receiver as follows Digital Input 1 __ Digital Output 1 Digital Input 2 _ Digital Output 2 Analogue Setpoint aa Digital Output 3 Analogue input 4 20 mA NEN Analog output 4 20 mA Thermocouple Input Not used WEN Communication Failure Comes on if no messages Setpoint Output Local indication mdi from WIO 800LT System OK On if system OK ERN System OK On if system OK QSG 800LT 1 7 May 2010 3 Unit components and connections Your WIO 800LT transmitter unit has the following components and terminal connections Earth ground wire n terminal on reverse side 24V gt Lu oa a z 2 5 So O z fe z zs zk ok x wR EOE u dd Su lo Free CUM n zc E 66004 880 0 ecoecoocooooooo Max
Download Pdf Manuals
Related Search
Related Contents
添付文書(PDF) The Best of Ottalini #3 Recaro Young Sport Bellini TDP-MT200 Actron CP7828A Operating Instructions Dolly User Manual Weiver 2.0 - testpower.se wifi remote controller Copyright © All rights reserved.
Failed to retrieve file