Home
User manual
Contents
1. Active channel signaling Diode 1 indicating preselection of control channel no 1 to operate skylight no 1 Diode 2 indicating preselection of control channel no 2 to operate skylight no 2 Diode 3 indicating preselection of control channel no 3 to operate skylight no 3 Diode 4 indicating preselection of control channel no 4 to operate skylight no 4 Diode 1 2 3 4 indicating preselection of control channel no 1 2 3 4 operate all skylights 2 SELECT button for changing control channels and programming 3 Button of MOVEMENT OPEN 4 Button of MOVEMENT STOP 5 Button of MOVEMENT CLOSE 6 Group of the buttons of movement to operate skylight 7 Group of the buttons of movement to operate accessories SRF EV SJP EV 8 Programming Button 1 Unscrew the securing screw in the back cover of the remote control 2 Slide up and remove the back cover of the remote control 3 Remove discharged 3 VDC battery and place a new one Replace the back cover and secure it with the screw QUICK START UP A FAKRO ZW amp FAKRO 1 Install the skylight according to the FVE in
2. N Working temperature up 10 C to 65 C Warranty Warranty The manufacturer guarantees correct device functioning It also undertakes to repair or replace the device if its defects result from material or structural faults The warranty period is 24 months from the purchase date fulfilling the following condiction e Installation has been performed by an authorised individual as per manufacturer recommendations e Seals remain intact and no unauthorised structural changes have been made e The device has been used in accordance with its intended use as per user manual e Damage is not a result of improperly made electrical system or atmospheric phenomena e The manufacturer is not liable for damage which occurred as a result of improper use or mechanical damage In case of failure the device must be submitted for repair with a Warranty Card Defects revealed within the warranty period will be removed free of charge no longer than 14 days after accepting the product for repair Warranty and post warranty repairs are performed by the manufacturer i e FAKRO PP Sp z 0 0 Quality Certificate Device Signature stamp of installing person FAKRO PP Sp z 0 0 ul Wegierska 144A 33 300 Nowy S cz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 2013 FAKRO 27 01 14 NC873 GB
3. GB FAKRO FVE Skylight Read the entire instruction before using the FVE Skylight www FAKRO com Contents Important information Contents Important information icici icsddcsdscacics dace venevevdsdacacacscdvavavavaccsceeevanduedsscasesanenadenexexanenandes 2 Description of the Skylight FVE wc ciiincencienicden nee eee anes 3 Description of the ZRC US controller cccccccccccccccecceeeeeeeeeeeeeeeenseseseaeeeeeeeeeeeeeeeeeeeeeeeeeeees 4 Quick start UD srecen e ores oe 5 Advence option Programing ZRC to skylight Changing Security Code 0 0 6 Other Information 2a as ein asacslasrsianrdacd steatosis O inet es Sad aid axon REECE EEEE ES 7 Conhetion of the ZAC US controller sis cssecscedeasisan aaa duncmdaersacinaieaiasiean EEEE T Manual emergency closing of the skylight 0 ceeeeeee sense e eee e eee eee eens ea eae eens ea eee eens sees ea eeeeaee T7 Raim Sensis ecean E a E 7 Warranty ocna n nanen e Eea Eaa ENE a bigs EEEa eeta eataa 8 Important information Read the entire instruction before using the FVE skylight e Make sure that insect screen is installed prior to operation of the skylight e FVE skylight and accessories when connected are factory set to operate in AUTOMATIC mode It means that one press of open button will open the skylight to it s maximum When close button is pressed the skylight will close totally In order to stop the skylight in desired possiti
4. align the chain along the cover and close the window This is only emergency solution Do not leave the house unattended as the skylight is possible to be opened from outside As soon as the power is restored put the chain to it s original position as well as the mosquito screen As the power can be restored at any time during unlocking the chain and the closing procedure of the skylight can be activated by rain sensors when raining to avoid personal injuries make sure the skylight is disconnected from the power main Rain sensors Rain sensors are pre installed at the factory The rain sensors ensure that the skylight automatically closes if it rains through the skylight Do not paint or varnish the rain sensors When the skylight is wide open it takes about 30 seconds before the skylight is completely closed Therefore during heavy rain water may enter the room before the skylight is closed fully Please pay particular attention if furniture is placed below the skylight The rain sensors may not react to very fine weak rain fog or dew Dirt on the rain sensors may cause operating problems Therefore it is recommended to clean the rain sensor with a soft damp cloth when needed Remember to switch off the power before cleaning Technical data Voltage Rated 100 240 VAC Current Rated 0 12 0 06 A Chain unfolding rate 7 5 mm s Power cable 2 x 0 75 mm Chain pushing force 200 N Closing force 200
5. anger of crashing While closing the motor exerts the force of 250N app 25kg Description of the skylight FVE FVE skylight is designed to be installed on the roof It is equipped with chain motor two rain sensors ZRC remote control unit and neccessary cabling to connect internal electric blind The FVE skylight can be powered with 100 240VAC 50 60Hz electricity Remote control ZRC has a factory setting to operate the FVE skylight on channel number 1 7 t 40 ok 3 O 6X5 FVE skylight program button IR receiver diode Settings signaling diode Cover Plug to connect ZKC keyboard Switch activating ZKC keyboard Gutter for the blind cable Cable connector for electric blinds connection SRF EV SJP EV Motor chain 0 Chain blockig screw in the sash gt OMNOAORWND Description of ZRC US controller The remote has 4 channels and within each channel there are two columns of control buttons First column of buttons controls FVE skylight and the second one controls the internal blind As standard factory settings opening and closing of the skylight is assigned to work on channel 1 of the remote Remaining channels can be used to operate additional skylights or electric blinds 1
6. buttons you change the status from 0 to 1 If you press A C E buttons the code will change into 1 0 1 0 1 0 In order the reset the security code press P button until diode 1 and 4 will light on Press P button again to reset the code After this the security code is set in the following combination 0 0 0 0 0 0 After the security code change YOU MUST repeat programming A with every skylight that will be operated with the remote 6 8 Other Information Connetion of the ZKC US controller As an option each of the FVE skylight can be additionally operated by ZKC US keypad In order to connect the ZKC US keypad to a FVE skylight you must remove the mosquito screen and the bottom cover Wiring requires also to drill a hole in bottom part of the frame to feed through the cable so it is recommended to plan the use of ZKC US keypad before any plastering will take place Side drawing shows wiring diagram between ZKC US socket and ZKC US keypad ZKC US keypad works in similar way as ZRC US remote control and require programming like in case of ZRC remote Manual emergency closing of the skylight In case of power failure the skylight if opened can be closed manually To close the skylight remove the mosquito screen and using the screwdriver unscrew the screw locking the motor chain in the chain socket Holding the sash
7. hole in the skylight s operator side plastic untill red indicastion light start flashing 2 Than point the remote towards the skylight and press one of the skylight movment buttons Once it s done the remote control code is stored in the skylights control unit memory IN If you have no access to skylight you can also start programing procedure by switching OFF power supply and than restoring it When red indication light start flashing you will have 10 seconds to point remote and send any command If you need to assign more skylights to the same or other channel repeat the procedure from point 1 After the programming is done corretly you will be able to operate skylights by changing the channel on the remote Channel no 1234 using to operate all skylight or blinds in the same time Operation of the internal blinds installed on each of the FVE skyligths is always done by the second group of buttons on the ZRC remote No 7 page 4 Change of the remote control code To obtain maximum security it is recommended to frequently change the security code Setting your personal code will give an assurance that the skylight s can be operated only from your own remote control unit To change the code Press programing button P 8 until diode 1 and 4 will light on During 10sek choose any combination of the security code by 2 pressing any of the movment buttons from A to F on the remote By pressing any of the A F remote
8. on you need to press stop button e Remote control ZRC has been designed for the use with FAKRO products Use of this unit with other equipment may cause malfunction e The batteries provided are 1xCR2450 3V e After removing the packaging make sure the equipment has not been damaged e Before connecting the equipment make sure that the supply voltage corresponds to the appliance voltage indicated on the technical data label on the equipment e This equipment must be only used for the purpose for which it has been built The manufacturer cannot be considered liable on any damages or problems arising from improper use e The installation has to be carried out in accordance with the instructions of the manufacturer The non observance of these instructions could compromise safety The power must be switched off when connecting the skylight installing accessories and whenever the cover of the electiric elements is removed e Call for a service when operator does not work properly e Make sure children will not be able to play with the skylight keep the remote away from children e Switch off the power to the system before you have your hand or body out of the skylight The motor automatically closes the skylight when rain sensor gets wet e To clean the skylight or perform the maintenance always switch of the power to the system e Disposal of used batteries shall conform with relevant environmental regulations WARNING D
9. stallation 1a Install and connect the internal blind according to instruction NC 142 the installation instruction NC955 or NC956 an option 2 Attach holder to the remote control in a location that c Check whether the remote control is firmly is convinient for you located in magnetic washer a Screw holder firmly to the wall with the use of anchor pins b Put the washer on the holder 3 Connect the skylight to the power source 4 Remove the protecting foil from the remote 100 240VAC Be carefull to avoid electric shock control battery and point the remote towards the skylight Select channel 1 Using first column of buttons lef side you will operate the skylight while the second column will operate the blind i If you does not react to the comment sent by remote from channel no 1 please go programming procedure from p 6 5 8 Advence option Programing ZRC to skylight Changing Security Code Infrared remote control ZRC allows to assign to each of the channels channel no 1 2 3 4 one or more skylights with the blinds Channel no 1 as standard is factory set to operate one skylight In order to add more skylights to next channel please follow below steps D Presing SELECT button on the remote choose channel no 2 Using small screwdriver press and hold the programming switch through the
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 - 東松山ケーブルテレビ Guia de Instalação Rápida TE100-MP1UN HF25 Technical Manual - AMADA MIYACHI AMERICA 取扱説明書を必ずご参照ください ENG Melissa 271-018 User's Manual Valueline SVL-CAM110 surveillance camera 4. Klicken Sie auf die [ScanSnap] ASUS RS720-X7/RS8 T7388 User's Manual CITAL® Copyright © All rights reserved.