Home

Warm N Cozy Blanket Warmer User`s Manual

image

Contents

1. Use soft and clean cloths to clean the stainless steel surfaces If more aggressive methods of cleaning are needed use a non abrasive scouring pad and make certain to scrub with the visible grain of surface metal to avoid surface scratches 2 1 DO NOT use wire brushes scrapers or metal scouring pads These will damage the stainless steel surface Cleaning Protocol 1 2 3 4 Always remember to clean the unit regularly as this will preserve the stainless steel surface NOTE Disconnect the device from the power source before cleaning the product Remove all detachable parts such as the blanket shelf and support assembly Clean these items separately Clean the interior metal surfaces with a damp cloth and any mild commercial detergent As stated before avoid using abrasive cleaning compounds Rinse surfaces by wiping with a sponge and clean warm water Remove excess water with a dry and clean cloth Leave doors until the interior of the device is completely dry NOTE It is important to dry the device completely as leftover water may cause oxidation rust and or corrosion Interior can be wiped with a sanitizing solution after cleaning rinsing and drying This solution should be approved for stainless steel surfaces The exterior of the cabinet should be cleaned with the same products that were used to clean the interior Cleaning products should be for stainless steel Clean the window glass with any standard commercia
2. use by qualified technical personnel 4 This manual should be considered a permanent part of this device This manual and all supplied instructions diagrams schematics parts lists notices and labels must remain with the device if the device 1s to be sold or moved to another location 5 CAUTION This device should ALWAYS have 1 inch of clearance on all sides in order to prevent overheating Warm N Cozy Blanket Warmers should not be left unattended for periods of longer than 24 hours In case of absences longer than 24 hours disconnect the warmer from its power source to avoid any technical difficulties CAUTION Used to indicate the presence of a hazard that can or will cause minor personal injury the warmers should not be left property damage or a unattended for periods of more than 24 hours potential unsafe practice if the In case of absences longer than 24 hours warning included with this disconnect the warmer from its power source symbol is ignored Used to notify personnel of installation operation or maintenance information that is important but not hazard related 2 Electrical Information POWER REQUIREMENTS K 210 120 V A C 60 Hz 1 ph 1 1 NEMA 5 15P S F A 15A 125V Plug 500 Watts 4 Amps q Hospital Grad Safety Class I Equipment POWER REQUIREMENTS KZ 710 120 V A C 60 Hz 1 ph 1 1 NEMA 5 15P 1000 Watts 8 Amps Sar ieee Safety Class I Equipment POWER RE
3. QUIREMENTS KZ 1400 120 V A C 60 Hz 1 ph p 1 NEMA 5 15P 1500 Watts 12 Amps Saf ee Safety Class I Equipment DANGER AT NO TIME SHOULD THE INTERIOR OR EXTERIOR BE STEAM CLEANED HOSED DOWN OR FLOODED WITH Hazardous WATER OR LIQUID SOLUTION OF ua ANY KIND DO NOT USE WATER JET TO CLEAN SEVERE DAMAGE OR ELECTRICAL HAZARD COULD RESULT WARRANTY BECOMES VOID IF APPLIANCE IS FLOODED A DANGER ENSURE POWER SOURCE MATCHES VOLTAGE STAMPED ON APPLIANCE NAMEPLATE Grounding reliability can only be achieved when equipment is connected to an equivalent receptacle marked Hospital Grade Medical Equipment classified by Underwriters Laboratories with respect to electric shock Fire and mechanical hazards only in accordance with UL 60601 1 and CAN CSA C22 2 No 601 1 ellis Protective Earth C US G d Symbol ja UL File No E363270 3 Description and Specification Sheet KZ 210 KZ 710 Mara 4 1 zy Model KZ 210 Desk Top Type Interior Capacity 2 1ft3 0 07 m3 Blanket Capacity Holds 7 blankets Dimensions Outer 16 W x 24 D x 20 H with legs Dimensions Inner 13 W x 21 D x 13 H Weight Net 70 LBS 32 Kg Weight Shipping 75 LBS 34 Kg Model KZ 710 With 4 Casters Interior Capacity 7 1ft3 0 21 m3 Blanket Capacity Holds 25 blankets Dimensions Outer 22 W x 29 D x 39 H with casters Dimensions Inner 19 W x 25 D x 26 H Weight Net 170 LBS 77 K
4. User s Manual Warm N Cozy Point A Technologies Inc 20957 Currier Road Unit C Walnut CA 91789 U S A TABLE OF CONTENTS 1 Safety Procedures and Precautions cece cece cece non 2 Electrical Information 0 cc cece cece ccc cceccucecscccenceceucseceees 3 Product Description and Specification Sheet oooooooocoocmncns 5 A Dimensional DPA WINS nadz r 6 7 5 Blanket Warmer Power Control Operation 2 22222211111 8 10 O Cleanin amp and Maintenance toi 1 SAFETY PROCEDURES AND PRECAUTIONS Knowledge of proper procedures 1s essential to the safe operation of electrically energized equipment It is important to follow these safety guidelines and be in accordance with generally accepted product safety labeling guidelines for potential hazards Warning symbols and signal words have been placed throughout the product 1 Blanket warmers are intended for warming blankets ONLY This device is not intended for any other purposes and 1s not recommended for other use 2 This device is intended for use in commercial establishments where all operators are familiar with the device s purpose operation limitation and associated hazards Operating instructions and warnings should be read and understood by all operators and users 3 Any troubleshooting guides component views and parts lists included in this manual are for general reference only and are intended for
5. com WWW Warmncozy com
6. g Weight Shipping 180 LBS 82 Kg Model KZ 1400 Double Compartment Warmer Double Doors With 4 Casters Interior Capacity 141t3 0 42 m3 Blanket Capacity Holds 50 blankets Dimensions Outer 22 W x 28 D x 69 H with casters Dimensions Inner 19 W x 25 D x 52 H Weight Net 350 LBS 159 Kg Weight Shipping 370 LBS 168 Kg 4 Dimensional Drawing KZ 210 410 16 1 617 24 3 _ 484 19 1 214 20 2 ee a3 132 aa KZ 710 i 260 22 0 e 736 29 0 DE 123 0 987 38 9 1257 49 5 KZ 1400 28 4 TT fee 7 564 22 2 M 169 EGZI 9491 1F91 1258 49 3 5 Blanket Warmer Power Control Operation Alarm display Measure value display Output display Data decrease Function key Data Increase Power Control 1 Turn on the blanket warmer by plugging the device into an electrical outlet make sure the electricity settings of your local outlet matches the settings of this device Use the circuit breaker switch which is located on the BACK PANEL of the blanket warmer to turn unit on and off 2 1 Turn the switch to the RESET option to turn the blanket warmer ON 2 2 Turn the switch to the OFF setting to turn the blanket warmer OFF WARNING always turn the device off via the circuit breaker switch before unplugging the device Temperature Control 1 The Factory default temperature is se
7. l glass cleaner Wipe the control panel door vents door handles and door gaskets regularly as these are areas that often harbor debris Always follow appropriate state or local health regulations regarding all applicable cleaning and sanitation requirements Preventative Maintenance 1 Ze 3 Do not exceed the unit s designed blanket capacity Always inspect the condition of the plug and chord Replace immediately if damaged as they can cause electrical injury and or damage Check the door gasket integrity If there are tears or if the gasket is worn or loose replace it A damaged gasket will allow heat to escape from the interior Always make sure the seal is tight to the unit body Inspect the air temperature sensor mount in the interior chamber Make sure the metal guard is in place and the wires are in working condition Check the following for maintenance the support shelf assembly and make sure pieces are not broken or missing baskets move smoothly and freely along the railing mounting bolts and the caster legs of the device are secure and the control panel overlay condition If there is excessive wear on the LED panel or if the buttons fail to work replace immediately Manufacturer Point A Technologies Inc Address 20957 Currier Road Unit C Walnut CA 91789 U S A Tel 909 869 8949 Fax 909 869 8959 Tech Support Line 866 3POINTA 376 4682 E mail info pointatech com Web Site www pointatech
8. lection has been made wait another 20 seconds for the LED screen to return to the actual temperature display again or press SET another 2 times 7 WARNING Once the temperature has been changed from Fahrenheit to Celsius or vice versa only the actual temperature display will have been calibrated to the new temperature setting The target temperature and alarm temperature must be calibrated via the arrows buttons to match the new temperature setting 7 1 Example the target temperature has been set to 120 degrees F the alarm temperature at 130 degrees F and the actual temperature displays 105 degrees F If I were to change from F to C then only the actual temperature display will change from F to C I would have to change the target and alarm temperatures manually using the up and down arrow keys Setting the Alarm 1 To set the alarm PRESS and HOLD the SET button for 2 3 seconds to access the first menu AL and a number should be flashing consecutively on the LED screen 2 Press the up or down arrow Keys to adjust the alarm temperature 2 1 NOTE the alarm light will go off only when the actual temperature goes ABOVE the alarm temperature that was set 3 Once an alarm temperature has been selected press the SET button another 9 times or wait another 20 seconds to exit the menu The LED display will then show the actual temperature again 4 WARNING setting the alarm temperature will NOT set the target temperature El Calib
9. rating the Thermometer 1 If for whatever reason the actual temperature display does not show the correct temperature please note the accuracy of the temperature the internal thermometer can be calibrated accordingly 2 To calibrate the thermometer PRESS and HOLD the SET button for 2 3 seconds to access the first menu 3 Press SET once more to get to the calibration setup SC and a number should be flashing consecutively on the LED screen 4 Press the up or down arrow keys to calibrate the thermometer holding either arrow key down will allow the number to dial faster The calibration range will be from 50 0 to 50 0 6 Once a desired calibrations editing has been chosen press the SET button 8 times or wait 20 seconds to exit the menu and return to the actual temperature display SA Attention Error Codes HH or LL flashing on the panel means that the device has a sensor error Should the panel display HH or LL use the circuit breaker switch on the back panel to turn the power off Turn the switch to the OFF setting and leave the device powered off for at least 1 minute before restarting the device Restarting the device should solve the issue 6 Cleaning and Maintenance Cleaning 1 Use non abrasive cleaning products designed for use on stainless steel surfaces When looking for a cleaning agent for the stainless steel surfaces 1 1 DO NOT use chloride compounds quaternary salts hydrochloric acids muriatic acids
10. t to 130 degrees Fahrenheit 1 1 After plugging in the blanket warmer and turning the device on please wait about 30 minutes for it to fully heat up To change the temperature of the device PRESS and HOLD the up or down arrow button for about 2 3 seconds Then select the desired temperature setting by pushing the up or down arrows to increase or decrease the temperature 3 Once a desired temperature has been selected push the SET button to save the temperature selection 3 1 If the SET button is not pushed the device will automatically revert to the previous temperature setting 3 2 The device will require 20 30 minutes to fully heat up or cool down to the newly selected temperature 4 The Out light will flash until the temperature inside the unit reaches the temperature set on the power control 5 The actual temperature may deviate up to 20 degrees F 12 degrees C above or below the actual set temperature Changing from Fahrenheit to Celsius 1 Factory settings are set to Fahrenheit 2 To change from Fahrenheit to Celsius access the 2 menu by PRESSING and HOLDING the up arrow and the SET buttons SIMULTANEOUSL Y for about 2 3 seconds 3 On the LED screen LoC and 0 should be flashing consecutively Press the SET button 5 times until CF and F flash on the screen consecutively 5 To change from Fahrenheit to Celsius press the down button once To change from Celsius to Fahrenheit press the up button once 6 Once the se