SO-111W User Manual

image

Contents

1.
2. SO 111W Microscope OPTIONAL ACCESSORIES FLOOR STAND BINOCULAR ASSISTANT MICROSCOPE VIDEO SYSTEM large and small monitor versions available OTHER ACCESSORIES Table plate Spare pair focus sterilisable covers Spare pair zoom sterilisable covers Spare handle sterilisable cover Side handle Gel cell battery 7Ah capacity Gel cell battery charger for SO 217 Gel cell battery 38Ah capacity Gel cell battery charger for SO 9210 SCAN OPTICS PART NUMBER SO 331 SO 1440 SO 1350 SO 291 SO 545 SO 546 SO 547 fits side handle SO 572 SO 217 SO 261 220 240V or SO 262 110 120V SO 9210 SO 9220 S0 111W Microscope PACKAGING ALUMINIUM CASE Scan Optics aluminium transit cases provide the best protection for a microscope where it 1s likely to transported to more than one location These transit cases are fitted with polyurethane polyetherfoam which houses the individual microscope subassemblies and p
3. Note that sterilised covers should be applied to the manual focus and zoom knobs and the guide handle if used before these parts of the microscope are touched by a sterile operator 1 Move the head into approximate position using the arm assembly articulations 2 Move the microscope focus up to the half way position This should leave approximately 25mm of movement up or down from the central position 3 Use the pantograph arm articulation to move the head up or down while looking through the eyepieces to roughly focus the microscope 4 If the microscope eyepieces are higher than the most comfortable position for the operator and it is not possible or practical to adjust the operator s seat rotate the tilt knob clockwise to tilt the head of the microscope down The range of tilt adjustment is from 45 downward to 5 above the horizontal Focussing the microscope in the correct sequence is an important step in setting up for use 1 Set the pupillary distance of the microscope by moving the eyepieces apart or together as required The eyepieces are geared together and will move equ
4. When the power supply is switched on soft start circuitry will turn the lamp on slowly to minimise thermal shock to the cold lamp which would otherwise reduce lamp life To change the light intensity simply rotate the intensity control knob found on the top panel of the power supply If battery power 1s used or cuts in due to a mains power interruption a slight decrease in light intensity may be noticed This is normal and the amount of light reduction will depend on the charge status of the battery being used Intensity control knob Mains switch Lamphouse cable socket Scan Optics recommend the use of gel cell or sealed rechargeable lead acid 12V batteries These batteries are maintenance free and can be operated charged or stored in any position without leakage I Tf the power supply is to be connected to a 12 volt de supply connect the battery cable to the 3 pin connector on the bottom panel on the power supply 2 Connect the red battery clip to the positive battery terminal and the black clip to the negative battery terminal The power supply will not operate 1f the terminals a
5. S0 111W Microscope The microscope arm is fitted with an adjustable gas spring By adjusting the position of one end of the gas spring the amount of upward force can be changed Thus if accessories are added to or removed from the microscope the force setting can be adjusted to compensate for the change in weight thereby maintaining the same desired feell of the arm movement To adjust the gas spring 1 With one hand push the pantograph arm down until it is in the horizontal position This will expose the socket in the adjusting screw 2 Using the 5mm socket key provided in the tool box rotate the screw clockwise to move the adjusting nut up and decrease the arm force Alternatively rotate the screw anti clockwise to move the nut down and increase the arm force CAUTION Always check the arm movement over the entire up down stroke of the arm If the microscope is heavily loaded with accessories and the arm force is set too low the arm may drop suddenly if it is not adequately restrained with the friction lock Gas spring adjustment shaft Ga
6. SO 111W Microscope SPECIFICATIONS Binocular stereoscopic VIEWING SYSTEM convergence angle 10 Eyepiece tube inclination 45 MAGNIFICATION Zoom magnification range 4 2 x 25x WORKING DISTANCE Auxiliary objective to object distance 160 mm FIELD OF VIEW 15 65mm depending on magnification REFRACTIVE ERROR 5D left eyepiece FOCUSING Range 25mm INTERPUPILLARY DISTANCE Adjustable for Distance PD range approximately 50 to 80mm ILLUMINATION ALIGNMENT Coaxial with viewing system high intensity LAMP 12V 50W guartz halogen lamp FILTERS Internal ultraviolet and infrared filters LAMP LIFE 20 hours at highest intensity 80 hours at medium intensity 75 000 Lux minimum at maximum setting with a new lamp EARTHING Via earth lead of mains power cable green yellow DIRECT CURRENT 12 V dc source optional CIRCUIT BREAKER 3A resettable type MOUNTING SYSTEM Adjustable gas spring to set lifting force Vertical pillar to head optical axis maximum 930 CASE OO DIMENSIONS Aluminium case 790 x 560 x 340 mm 31 x 22 x 13 5 Including packing carton DIMENSIONS Standard packaging 810 x 520 x 290 mm 32 x 20 5 x 11 5 WEIGHT In aluminium case 30 kg 66 Ibs Including packing carton WEIGHT In standard packaging 18 kg 40 lbs
7. SO 111W Microscope SYMPTOM POWER SUPPLY in Y gt o 9 Z zal The light is too dim There is no light There is no power FIRSTSTEP ___ Remove the lamp module and check for blackening or failure Check the intensity setting on the front panel The intensity may be set low Check if there is mains power available green LED on the main switch Check the intensity setting on the front panel The intensity may be set to zero Check if the lamp module is correctly inserted in the side of the lamphouse Check if the cable is connected to the socket on the top panel of the power supply Check the power supply Check the mains power supply Turn the mains power off and check the circuit breaker on the bottom panel REMEDY Replace a blackened or failed lamp Increase the lamp intensity using the adjusting knob Switch to battery power if no mains power is available Increase the lamp intensity using the adjusting knob Ensure the module clicks positively into place If not connect it See below Use battery power 1f no mains power is available Push the circuit breaker back in after waiting a few minutes
8. 5 Remove the eyepiece blanks and insert the eyepieces Insert the focusing eyepiece in the LHS eyepiece tube from the observerls perspective and secure in place so that the scale marker is easily visible Place the fixed eyepiece in the RHS eyepiece tube and secure using the screw Retain the eyepiece caps in a safe place for when storing the microscope Focussing eyepiece Securing screw OBSERVER S LHS Eyepiece blanks Fixed eyepiece Securing screw OBSERVER S RHS 4 SO 111W Microscope The Scan Optics Ophthalmic Microscope may be connected to either an earthed mains 100 240V 50 60Hz ac supply or a 12V dc supply or both If both ac and dc supplies are connected the dc supply eg 12V battery will act as an emergency backup for mains power In this case the microscope will not run from battery power unless the mains supply fails or is switched off If mains power is restored the microscope will resume using mains power
9. 20 ADVANCED INSTRUCTIONS wwa O io 21 Replacing mould protection 21 Adjusting focus friction 23 TROUBLESHOOTING escrase 24 SPECIFICA HON APP ME AE T A N EE Ocz 26 SO 111W Microscope INTRODUCTION Please read the following information carefully before installing and using the Scan Optics ophthalmic microscope Scan Optics is responsible for the safety reliability and performance of the equipment only if it is used in accordance with these instructions This microscope is designed for use by a certified practitioner for magnified observation of patients and for use in an operating theatre as an observation aid during surgery Environmental storage and packing conditions of 60 95 relative humidity and 10 40 C are recommended for this product No parts or accessories supplied with this microscope are supplied in a sterile condition Apart from those identified in the instructions within this manual there are no user serviceable parts in this microscope Scan Optics will retain the discretion to advise whether any repairs may be carried out by external qualified technical personnel or whether part s of the microscope must be returned to the manufacturers premises
10. loosen the focus friction Release the LHS knob and test the feel lof the focus system by rotating either the LHS or RHS knob on its own The system should allow the microscope head to be focussed up or down easily without falling under its own weight Poea T RHS focus knob LHS focus knob SO 111W Microscope TROUBLESHOOTING SYMPTOM FIRSTSTIEP OO REMEDY If the microscope or object has moved it may no longer be in focus A different user may require adjustment for their refractive r The image is blurry mor 9 Check the eyepieces for Y cleanliness Z z Check the objective lens for 5 cleanliness No image is seen Check for obstructions in the viewing path The focus system allows the a microscope to fall gt 7 under its own Y weight 3 The focus system is Check for obstructions The microscope is falling under its too stiff Loosen the arm friction handle and observe if the pantograph arm offers any significant resistance to downward pressure own weight Locate the gas spring adjustment near the elbow joint between the arms Check that the microscope is securely clamp
11. zoom optics do not disclodge the pellet Screw the cover back on Replace the prism protector on the auxiliary objective assembly making sure that the slot lines up with the location of the lamphouse prism Replace the microscope head back in the mounting ring and re tighten the retaining screw Update the anti mould label on the microscope head or replace 1t with a new label lt Anti mould pellet location Pellet shown in place S0 111W Microscope Over time depending on the frequency of use the focus friction may loosen so that the microscope head starts to fall under its own weight Conversely the focus knobs can be inadvertently tightened so that they are difficult to turn To adjust the focus friction to a suitable level While viewing the microscope from the front mounted on the pantograph arm Hold the left hand side focus knob firmly Rotate the right hand side focus knob clockwise to tighten the focus friction Rotate the right hand side focus knob anti clockwise to
12. 50 11 IW microscopes are fitted with anti mould protection In tropical climates routine checking for the presence of mould is recommended SO 111W Microscope LIGHTING SYSTEM 8 The main lamp supplied has a rated average life of 50 hours however the actual life of the lamp will depend on the intensity setting normally used The highest setting 1s an over run setting which increases light output but will reduce lamp life to about 20 hours Conversely running the lamp at a mid range setting will produce a lamp life of about 80 hours It is strongly recommended that the lamp be replaced as a routine maintenance task to reduce the possibility of failure during surgery 1 Always use protective gloves while replacing the lamp as lamp temperatures may be sufficiently high to burn skin should it come into contact with the guartz capsule Where possible allow the lamp to c
13. Clamp and power supply assembly Accessories SO 111W Microscope ASSEMBLY INSTRUCTIONS 1 Fix the clamp to the operating table about 40 cm from the head of the table The clamp may be fixed on either side of the table Make sure that the clamp 1s pressed firmly against the side of the table before tightening 2 Alternatively the clamp may be mounted on any horizontal surface that can be positioned within 60 cm of the working position such as a mobile trolley 3 It is important that the mounting surface be free from vibration and movement Note that in cases where the mounting surface 1s not rigid over tightening of the vertical clamp will not improve microscope stability In this case add a stiffening plate such as Scan Optics Table Plate Cat No SO 291 beneath the mounting surface and apply the clamp over the stiffening plate and the original mounting surface 1 Locate t
14. SCAN OPTICS USER MANUAL SO 111W OPHTHALMIC MICROSCOPE H S0 111W Microscope SO 111W Microscope SO 111W Microscope TABLE OF CONTENTS INTRODUCTION aasal al AA iccin 5 PARTS E Aaa Wai TNTET AA 6 PACKAGING Gi ela laama aakri aimamisi 9 ASSEMBLY INSTRUCTIONS ulises 10 Fixing to a table 10 Assembling the arm and head 10 Comnecting to a power source 13 Changing the light intensity 14 Battery operation maintenance and safety 14 Arm assembly adjustments 15 Gas spring adjustment 16 Microscope head assembly 17 Tilt function 17 Zoom function 17 Focus function 17 USING EHE MICROSCOPE weed aoc O OE W 18 Sterilisation 18 Moving the head into position 18 Focussing the microscope 18 ROUTINE CARE AND MAINTENANCE aaaaaaaaaaa aaa e eee aaa ooo ooo aaaaaaaa 19 OPTICAL HEAD 19 Cleaning the optical components 19 Cleaning the plastic parts and paintwork 19 Do not dismantle 19 Protection against mould 19 LIGHTING SYSTEM 20 Lamp lite 20 Replacing the lamp
15. al distances on either side of the optical centre of the microscope 2 Set the refractive error scale to zero on the LHS eyepiece 3 Choose a high magnification zoom setting or one which is typically used in surgery 4 Close the left eye and look through the right eyepiece of the microscope with the right eye only 5 Focus the microscope slowly until the image is sharply in focus 6 Close the right eye and look through the left eyepiece of the microscope with the left eye only 7 Rotate the refractive error adjustment ring on the left eyepiece until the left eye is in focus The reading on the ring will give an approximate measure of the relative refractive error between the left and right eyes 8 Look through both eyepieces normally and check that the image is focussed and that stereopsis 1s achieved SO 111W Microscope ROUTINE CARE AND MAINTENANCE OPTICAL HEAD The eyepieces objective lens and lamphouse prism should be checked for cleanliness each time the instrum
16. automatically The mains power switch on the microscope does not switch the battery off Connecting a 12V battery to the power supply while mains power is operating normally will not charge the battery 1 Plug the mains power cable into a mains power socket Use the cable retaining clip to secure the cable in place International safety standards do not allow the use of an extension cord The mains power supply must have a protective earth conductor If there in no earth conductor or if the integrity of the earth conductor arrangement is in doubt the equipment must be operated from a 12Vdc power source 2 Switch on the mains power supply at the mains socket The power supply will automatically detect the input voltage between 100 and 240V When the ON OFF switch is selected to ON the power supply indicator on the switch will light up and the lamp will come on if the lamphouse cable is connected to the socket on the top panel of the power supply IEC mains socket Cable retaining clip SIX 800006 009000 eevee 09000 e e Z 4 Battery connector Circuit breaker S0 111W Microscope
17. ed to a stable horizontal surface MOUNTING SYSTEM The microscope is not stable knobs have been set correctly Check 1f the microscope head is seated correctly in the wrist joint Check that the appropriate friction Refocus the microscope Adjust the eyepieces for refractive error refer Focussing the microscope Carefully remove and clean the eyepieces 1f they are dirty then replace them Carefully clean the objective lens taking care not to damage the lamphouse prism Check that the eyepieces have i Insert the eyepieces been inserted Remove the obstruction Adjust the focus friction refer Advanced instructions Adjust the focus friction refer Advanced instructions If it does not then the gas spring may have failed Contact your distributor local service agent or Scan Optics Adjust the gas spring to compensate for additional load on the end of the microscope arm refer Gas spring adjustment If not change the mounting surface to a more appropriate one Use the optional Scan Optics SO 291 table plate to stiffen a thin mounting surface such as a sheet metal table or trolley Refer Arm assembly adjustments Refer Assembling the arm and head
18. ent is used Surface dust should be removed with a clean soft brush Fingerprints irrigation solution residue and grease may be removed by lightly wiping with a cotton cloth or lens tissue moistened with a mixture of 70 ether and 30 absolute alcohol either ethanol or methanol Use pure alcohol if no ether is available Do not use acetone as it may damage the surface coatings of the lenses Prism Objective lens H Use water based cleaners only Do not use any organic solvent such as alcohol ether or xylene Apart from instructions specifically mentioned within this manual no parts inside the optical head of the instrument can be serviced by the user Attempts to dismantle the optical head or prism cover will make any warranty void In hot and humid climates it is common for mould to grow on optical surfaces Cleaning and repairing the damage can be expensive and inconvenient To minimise the risk of mould forming do not leave the instrument without either eyepieces or eyepiece blanks inserted and always store the optical head in a sealed bag containing silica gel desiccant Scan Optics
19. ers are provided for fitting over the zoom knobs when sterile use is required To focus the microscope up or down simply rotate the focus knob s The total focus range is 50mm For optimum microscope use leave the microscope head in such a position to allow approximately 25mm of focus range in each direction Sterilisable covers are provided for fitting over the focus knobs when sterile use is required SO 111W Microscope USING THE MICROSCOPE Scan Optics microscopes are supplied with two sets of sterilisable covers one set may be used while the other set is undergoing sterilisation Additional sterilisable covers may be purchased from Scan Optics in the event of loss or damage Simply slip the covers on to the zoom or focus knobs when reguired The covers may be sterilised by boiling autoclaving chemical sterilisation gas sterilisation Note that national authorities may require the use of specific sterilisation or disinfection methods
20. for service or repairs to be carried out under warranty or otherwise Where appropriately qualified technical personnel are identified by a user and ratified by Scan Optics then Scan Optics will make available on request any information which may assist in maintaining or repairing this equipment Scan Optics Pty Ltd 32 Stirling Street Thebarton SA 5031 AUSTRALIA www scanoptics com au support scanoptics com au SO 111W Microscope PARTS LIST MAIN ASSEMBLIES Microscope head assembly Arm assembly SO 111W Microscope PARTS LIST CONT OTHER Focus sterilisable covers 4 Zoom sterilisable covers 4 Plain eyepiece 1 Spare lamp 1 User manual 1 Focusable eyepiece 1 this manual m O as Socket keys set7 Dust cover 1 Lens cloth 1 1 5 2 2 5 3 4 5 6 mm Y Battery cable 1 Mains cable 1
21. he elbow knob allows the shape of the arm to be locked in position that is the position of the pantograph section relative to the horizontal section of the arm assembly The friction handle allows the vertical movement of the pantograph section of the arm assembly to be restricted or locked in position The wrist knob allows the head assembly to be locked in position relative to the pantograph section of the arm assembly This knob should not be unlocked after the head assembly has been adjusted This will prevent accidental dislodgement of the head assembly when attempting vertical positioning manoeuvres In a typical configuration the pillar knob would be left slightly loose but the elbow and wrist knobs would be locked Note that the safety clamp must be in position directly under the horizontal section of the arm assembly for safe operation of the microscope this will prevent the arm assembly sliding down the pillar The friction handle could be set such that when vertical adjustments of the pantograph arm are made the arm will stay in position after being moved This will allow the microscope to be swung out of the way about the pillar after surgery while the patient is moved When the next patient is ready the microscope can be swung in again and it will already be in a good approximate position Horizontal section Elbow knob he Pillar knob Wrist knob Friction handle Pantograph section
22. he pillar safety clamp and place it on the pillar if it is not there already Tighten the pillar safety clamp at a point midway up the pillar 2 Place the arm assembly on the pillar Make sure that the arm assembly rests against the pillar safety clamp Loosen the elbow knob to allow the pantograph arm to rotate about the elbow joint Elbow knob y Y SA Arm assembly Eo SO 111W Microscope 3 Locate the microscope head assembly in the end of the arm assembly Make sure the microscope assembly is seated all the way down in the collet Tighten the wrist knob underneath the end of the arm assembly to secure the microscope in the collet 4 Pass the cable through the clips on the arm assembly and attach the plug to the socket on the top of the power supply This will ensure the cable does not obstruct the surgeon or come into contact with the sterile area Collet Head assembly Wrist knob Socket SO 111W Microscope
23. ive for approximately three years However the effective life of this protection will depend on environmental factors such as the temperature and humidity of the place where the microscope 15 stored Regular inspection of the microscope will help early identification of mould and alert the user of the need to replace the anti mould protection To replace the anti mould pellet Zoom the microscope to the lowest magnification setting Loosen the retaining screw at the front of the microscope head Lift the microscope out of the mounting ring Remove the prism protector from the auxiliary objective assembly by prying 1t apart Unscrew the cover from the bottom of the microscope head The location of the existing anti mould pellet will be revealed from the front of the microscope head 6 Remove the old anti mould pellet ee silva Anti mould pellet 4 Auxiliary objective assembly _ Cover t __ Prism protector i Mounting ring p Retaining screw S0 111W Microscope 11 12 Peel the adhesive backing from the new anti mould pellet and place it in the same location Zoom the microscope in and out all the way to make sure the
24. ool before replacing it Ensure that the new lamp is free of grease or finger prints before replacement Any such marks should be removed with a solvent such as ethanol to avoid reducing lamp life 2 First grip the lamp module located beneath the cable gland on the side of the lamphouse Pull the lamp module out to reveal the lamp 3 Grip the lamp at the side of the gold section where the rectangular cut out is located and pull the lamp out of the lamp module Do not attempt to pull the lamp out by gripping the guartz capsule 4 Push the new lamp into the lamp module so that the lamp flange sits flush on the front of the gold tube section Replace the lamp module in the socket in the lamphouse so that the pins elick into place Correct lamp replacement using this method is essential for ensuring good illumination Lamphouse Socket Quartz capsule Lamp module A Grip here SO 111W Microscope ADVANCED INSTRUCTIONS The microscope 1s fitted with anti mould protection which is effect
25. re reversed The 12 volt supply must be direct current The power supply will not operate with 12 volts alternating current Ensure batteries have adequate airflow around them before charging Avoid short circuiting batteries Old lead acid batteries of any type must be disposed of correctly It is recommended that they are recycled by an appropriate establishment who recycle car batteries Lead acid batteries should not be disposed of with ordinary waste as lead poisoning or acid trauma may result Where battery backup is used Scan Optics recommends a periodical check of the battery to ensure it is charged and functional S0 111W Microscope The arm assembly includes a number of features which enable the microscope to be adjusted in almost any position The best combination of settings will depend on the individual user and the particular surgical environment The pillar knob allows the arm assembly to be locked in position about the pillar T
26. rovides excellent durability NYLON CASE As an alternative microscopes can also be packed in a reinforced nylon suitcase which is indistinguishable from normal luggage These cases are also fitted with polyurethane polyetherfoam and are lighter than aluminium cases STANDARD PACKAGING Where microscopes are unlikely to be transported to more than one location the standard packaging provides solid protection within a double walled corrugated carton Polyethylene foam inserts are provided to protect the contents of the carton Please do not dispose of these packaging materials but retain all the packaging within the carton for future use The head assembly box contains an upper and lower moulded cushion which support the head assembly Retain these cushions within the box for future use RE PACKING If the microscope is to be stored or transported it is recommended that the original packaging be re used for this purpose If possible re pack each assembly in its original plastic bag including a dehumidifying silica gel desiccant in the bag to reduce moisture The best storage location is a low humidity dust free environment such as an air conditioned room Head assembly y Head assembly e Pantograph arm Oj Power supply top foam assembly foam assembly Power supply ki bottom foam gs j assembly BP P p Power supply top foam assembly Accessories NOTE Outer box not shown Pantograph arm
27. s spring i SO 111W Microscope A good working knowledge of the microscope head assembly will be of great assistance in achieving and maintaining optimum optical and mechanical performance Lamphouse Fixed eyepiece Lamp module Lamphouse cable Focussing eyepiece Tilt knob es varad E Zoom knob Retaining screw Focus knob 7 Accessory mounting plate F To tilt the head assembly up or down simply rotate the tilt knob anti clockwise or clockwise accordingly Note that the entire head assembly will tilt not just the eyepieces To ease this operation support the weight of the microscope head with one hand while using the other hand to rotate the knob Prism protector To zoom the image in or out rotate the zoom knob s The total zoom range is between 4x and 25x magnification Sterilisable cov