1. The MIG240UL00 micro inverters may contain high voltages and the risk of electrical shock even when no external voltage is present Only the trained qualified electrical personnel are allowed to perform the electrical installation wiring opening repair and modification of the MIG240UL00 inverters MIG240UL00 micro inverters are designed to operate at full power at ambient temperatures as high as 65 C 150 F The micro inverter housing is designed for outdoor installation and complies with the NEMA 6 environmental enclosure rating standard The temperature of the heat sinks outside of the device can reach over 85 C in normal operation To reduce risk of burns use caution when working with micro inverters Both AC and DC voltage sources are terminated inside this equipment Each circuit must be individually disconnected before servicing and when the photovoltaic array is exposed to light it supplies a DC Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the device The manufacturer assumes no liability for the customer s failure to comply with these requirements Electrical installation must be carried out correctly to meet the applicable regulations and standards MIG240UL00 inverters shall be able to be enduringly installed MIG240UL00 inverters shall be installed as per the instructions stated in this manua
2. grounding conductor in AC cabling systems Align MIG240UL00 holes with the holes on the rack and tighten the screws properly 22 STAINESS FENDER WASHER x SY SS GROUNDING WASHER 3 MIG240UL00 has a clip to hold the Grounding electrode conductor After spreading the grounding secure it with the clip supplied 23 1 at o GROUNDING 6 TERM NAL 2 o r 1 i es wee a GROL JNDING x ae x STERMINAL _ z 2 h dii 4 SS Ss 4 Connect the micro inverter with the trunk cable 24 a Indicate the approximate center of each PV module on the PV rack Evaluate against potential collection of moisture or water for the most suitable angle to mount the inverter b Evaluate the location of the micro inverter with respect to the DC junction box Ensure that the inverter does not obstruct the PV module frame or stiffen braces and that the connector from one micro inverter can easily reach that of other Inverters z 5 Install the AC Branch Circuit Junction Box a Measure service entrance conductors to confirm AC service at the site Acceptable ranges are shown in the table below 240 Volt AC Single Phase L1 to L2 211 to 264 Vac L1 L2 to neutral 106 to 132 Vac b Mount an adapter plate at a suitable location on the PV racking system typically at the end of a row of modules The adapter plate m
3. DARFON MIG240UL00 Micro Inverter USER MANUAL TABLE OF CONTENTS IMPORT SAFETY 5 2 READ TRAC Eb aaa 2 LIEBODLUC LULDR nn R yaddas a f 5 AEE e s n 5 2 SAFTETY OF 72 55 2222 7 2 1 Planning the installation 8 88 7 2 cu 1116 ICI ONG n b b s 8 2 3 Installation and Operation 8 2 4 lechnical SpeCiliCaiOn 11 29 LED TORN AN 12 3 13 4 COMPATIBLLITY AND CAPACITY 14 o INSTALLATION 14 Dl PAGS TOOS 15 5 2 Installation of micro inverter on the back of the solar panel 16 5 3 Installation of micro inverter on the solar panel rack 22 5 4 Installation Map 28 5 5 Sample wiring diagram 240Vac single phase 29 IMPORT SAFETY INSTRUSTIONS READ THIS FIRST SAVE THESE INSTRUCTIONS This manual contains important instructions for Darfon MIG240ULO0 that shall be followed during installation and maintenance of the micro inverter Before using this unit please read these operating instructions carefully Take special care to follow the warnings indicated in t
4. art OF Flash programming O off flash 2HZ 3 VVARRANTY LIABILITY lf a fault or defect is present on receipt of the unit which is within DARFON s scope of responsibility DARFON shall have the right to either repair the fault or supply a replacement unit Replaced parts shall be the property of DARFON Should the fault repairs or replacement delivery not be successful the statutory provisions shall be valid The period of warranty shall be 25 years beginning on the date of purchase Please retain your receipt as proof of purchase Should your micro inverter require servicing please contact your dealer or DARFON Customer Service No responsibility shall be accepted for damage caused through any of the following reasons Unsuitable or improper storage or use incorrect installation or commissioning by the owner or third parties changes or modifications incorrect or negligent handling overuse chemical electrochemical or electrical interference unless this is attributable to negligence on the part of DARFON ELECTRONICS CORP If DARFON provides and individual warranty this means that the unit supplied will be free of faults for the length of the warranty period 13 2 Type mounted on the PV racking 4 COMPATIBLLITY AND CAPACITY Electrical Compatibility Grounding Terminal Model Number PV MPPT Voltage Range PV Module Connector Type Mounting Bracket 4 Locking MIG240UL00 24V 40V Tyco Solarlock Locking DC Con
5. dule due to module mismatch shadows from trees or chimneys or obstructions from leaves or debris does not degrade the performance of other modules and therefore has minimal impact on the power harvested from the PV array This typically results in improved power harvest of up to 20 from the solar PV system and represents a significant cost performance advantage Improved safety as power conversion from DC to AC is done at each solar module high voltage DC wiring is eliminated making the solar system intrinsically safer and specialized DC practices or equipment are not required for installation Increased lifetime and reliability it eliminates the single most common cause of failure in solar PV systems the string or central inverter which typically requires replacement at least once over the life of the solar modules adding significant cost DARFON s solar micro inverters have been designed for high reliability operations to operate in real world conditions from 40 degrees C to 65 degrees C without degradation of performance and achieve a peak efficiency of 94 1 over the temperature range Enhanced monitoring capability performance monitoring of the PV array is highly enhanced as each module s performance be viewed a capability not available with string inverters This uniquely provides users and installers with real time detailed information to ensure that the solar system performance is optimized over the lif
6. e of the installation The information can be used to promptly detect performance issues and pinpoint the exact location and nature of the problem which provides precise guidance for required maintenance a capability not possible with string inverter systems Simplified PV array design and installation for rooftop installations solar modules can be installed on any available space resulting in ease of design of the PV array compared with conventional inverter installations where design of the PV array module placement is complicated by shading issues This makes solar installations easier faster and cheaper to implement Also installers do not need to match the performance levels of adjacent solar modules in order to optimize the performance of the PV array The advantages of DARFON s Micro Inverter MIG240UL00 is primarily reflected in its high efficiency and long life Careful optimization of the overall inverter system s cost and efficiency lead to the choice of a micro inverter for use with one arrays per inverter Solar PV Modules Connected in Parallel 240 ac 60 hz DARFON MIG240 ae This micro inverter uses Darfon s proprietary maximum power point MPPT tracking technology to get the maximum amount of energy form the solar array which helps your arrays to have maximum output at all times 2 SAFETY OF INSTALLATION 2 1 Planning the installation For the safety of installation personnel must remove all cond
7. he unit itself as well as the safety suggestion listed below Safety Symbols To reduce the risk of injury and to ensure the continued safe operation of this product the following safety instructions and warnings are marked in this manual Warning risk of electric shock The lighting flash with arrowhead symbol within an equilateral triangle is intended to alert the user of the presence of dangerous voltage within the product s enclosure that may be constitute a risk of injury or death to users and or installers Caution refer to accompanying documents The exclamation point within an equilateral triangle is intended to alert the user of the presence of important information to prevent damage to this oroduct VVarning Risk of Electric Shock Do Not Remove Cover No User Serviceable Parts Inside Refer Servicing To Qualified Service Personnel Repairs and internal servicing should only performed by an authorized service personnel Both ac and dc voltage sources are terminated inside this equipment Each circuit must be individually disconnected before servicing and when the photovoltaic array is exposed to light it supplies a DC voltage to this equipment Hot Surfaces To reduce the risk of burns Do not touch Enclosure Rating type 6 raintight A Caution Perform all electrical installations in accordance with all applicable local electrical codes and the National Electrical Code NEC ANSI NFPA 70
8. he utility grid only after receiving prior approval from the electrical utility company Do not stand on a wet location while doing installation and wirings Enclose the outer covering well before switch on the circuit breakers The AC and DC connectors are tool removable only please ensure the micro inverter is not disconnected from the PV modules under load and switch off the circuit breakers Latch Swings Open Wieland ALTW APP Disconnecting AC connector Disconnecting DC connector Allowed changes in your electrical system to be carried out only by qualified electricians A Caution Lightning surge suppression Lightning does not actually need to strike the equipment or building where the PV system is installed to cause damage Often a strike nearby will induce voltage spikes in the electrical grid that can damage equipment Darfon s Micro inverters MIG240UL00 have integral surge protection much higher 2 4 Technical Specification Input Data DC Recommended input power STC Maximum input DC voltage Maximum Peak power tracking voltage Min start voltage Max DC short circuit current than most traditional inverters However if the surge has sufficient energy the built in protection in the device would exceed and the device can be damaged As the Darfon Limited Warranty does not cover extraordinary and unexpected manifestation of the forces of nature such as lightning strike
9. l Connect the MIG240UL00 inverter to the grid only after receiving prior approval from the electrical utility company Warning This unit is not provided with a GFDI device and intended to be installed under the Solar Module therefore please dont install this unit where it is expected to be contacted by any person 1 INTRODUCTION 1 1 General Thank you for choosing DARFON s MIG240UL00 Micro Inverters as your power conversion device for your solar power system DARFON s MIG240UL00 micro inverter is a compact unit which is installed at the back of each solar module to convert DC power generated by solar module to AC power for powering your house appliances and connecting to the electricity grid without the need for a string or central inverter The output from MIG240UL00 micro inverter is synchronized and in phase with the electricity grid DARFON s micro inverter solution has a number of distinct advantages Optimal energy harvest it maximizes the power harvested from each solar module and therefore the entire PV array This is accomplished by performing Maximum Power Point Tracking MPPT an electronic technique for maximizing the power harvested from each module under varying environmental conditions and performance monitoring for each individual solar module Performing MPPT on each solar module ensures maximum harvest of energy even under partially shaded conditions Degradation in the performance of any one mo
10. nector or Amphenol H4 Locking DC Voltage and Capacity Maximum number of MIG240s per AC Branch Circuit Overcurrent Protection 240V with 10AWG AC Trunk Cable 30Amp Breaker 20Amp Breaker 5 1 Parts and Tools 240V with 12AWG AC Trunk Cable NOTE 1 DO NOT exceed the maximum number of micro inverters in an AC branch circuit as listed in the table above 2 Each AC branch circuit must be protected by a dedicated circuit breaker of 30A or less if using 10 AWG trunk cable or 20A or less if using 12 AWG trunk cable 5 INSTALLATION PROCEDURE Outline drawing MIG240UL00 micro inverter 1 Type mounted on the back of the PV panel Mounting Bracket Grounding Terminal AC Grounding Terminal 0 DC Connector 14 This section provides a list of products parts and tools needed for installing and setting up the PV system Products e MIG240ULOO micro inverter e PV module e PV racking with a DC junction box attached to one of its ends Parts e Cables and related parts DC and AC cables with DC connectors and AC T branch connectors Cable clips Sealing caps for any unused drops on the AC Cable Terminators one needed at the end of each AC branch circuit e AC junction boxes e Gland or strain relief fitting one per AC junction box 15 Tools e Torque wrench sockets wrenches for mounting hardware e Adjustable wrench or open ended wrench for terminators The micro inverter can be moun
11. s therefore it is Max input current Output Data AC Maximum output power 220W Nominal output current 0 917A recommended to install surge protection as part of any solar installation We recommend the following protection devices These have been tested to ensure that they do not interfere with power line communications Install per vendor instructions Residential Efficiency Vendor Citel Part Number DS72RS 120 Application Residential 120 240V Split Phase where N G bond exists Commercial CEC weighted efficiency Vendor Citel Part Number SP 120 Application Branch panel protection See the vendor datasheet for DS70R which includes the DS72RS 120 or for SP 120 at Nominal voltage range 211 240 264 V Nominal frequency range 59 3 60 60 5 Hz Power factor 94 10 Mechanical Data 40 C to 65 C Peak inverter efficiency Nominal MPP tracking Operating temperature range Ntto www citelprotection com english citel_data_sheets ac_protection 10 11 Night time power consumption 51mW Dimensions WxHxD 200mm x 130mm x 3 mm EN 61000 6 2 EN Compliance 61000 6 3 FCC Part15 Class B UL 1741 IEEE 1547 2 5 LED Information Initialization Meet input start voltage ff MPPT Grid mode ff Warning message derating m flash Off on Off Off Off Halt manually Calibration Off off fault with restart Off off Off off ff o o o o ff flash 2HZ flash 0 5Hz Fault without rest
12. ted and installed on the back of the PV module panel screvv tightened to the frame of the panel or on the standard PV racking depending on the plan for layout of your PV system 5 2 Installation of micro inverter on the back of the solar panel Outline drawing Solar panel PV module and micro inverter Mounting Bracket Grounding Terminal ACI Grounding Terminal Mm Connector 16 1 Original PV Panel ae r em pi zz T Te 2 Add holding device and snap it to the panel frame 3 Drill screw holes M5 5 5 Install accessory M4 support bolts x 3 First peel off glues on the back 4 Drilling completed 6 Support bolts installed 18 19 7 Mount the micro inverter and line up the screw holes Photo of Actual Finish on the inverter with the three M4 bolts Spin the three M4 nuts on the bolts and tighten them with a wrench 20 21 5 3 Installation of micro inverter on the solar panel rack PV module racking Outline drawing micro inverter Mounting Bracket Grounding Termina 1 Lay out the trunk cable at the location required With the trunk connectors aligning with the position where the micro inverter needs to be installed secure the cable on either side of rack using tie wraps or clips 2 MIG240UL00 requires a separate equipment grounding conductor such as Wiley VVEEB grounding washers or other similar parts which can provide with an equipment
13. uctive jewelry or equipment during the installation or service of the device parts connector and or wiring The permanently wired equipment must be installed by licensed electrician Please follow all the instructions carefully and adhere to all the information on cautions or warnings 2 2 Servicing instructions Only the trained qualified personnel are required to mount operate correct or repair this device This list does not contain all measure pertinent to the safe operation of the device If any special problems arise which are not recorded in this manual please contact our authorized dealer service partner DARFON customer care for the information 2 3 Installation and Operation Installation of the device must be in accordance with the safety regulations and all other relevant national or local regulations Connect the male end of the micro inverter DC connector cable to the female end of the PV module connector cable Connect the female end of the micro inverter DC connector cable to the male end of the PV module Grounding symbol Grounding Terminal Grounding Terminal AC DC DC Connector Correct AC DC grounding and short circuit protection must be provided to ensure operational safety Read all instructions and cautionary marks in the manual carefully before start the installation Switch off the circuit breakers before installation and wirings Connect the micro inverter to t
14. ust be installed with an appropriate junction box c Connect the open wire end of the AC interconnect cable into the junction box using an appropriate gland or strain relief fitting The AC interconnect cable requires a strain relief connector with an opening of 3 8 inches in diameter 26 27 Sample Wiring Diagram 240 Vac single phase with monitoring Darfon Micro Inverter Installation Map system 3923 o pu uo payeysu de pug 3922 1 ZTSDAAV YPM PND 2 Jad SoPZDIW ZT 03 dn 40 3Q22 LOTHOMY YPM Pn yrueig s d SOPZDIW 52 03 dn pisul Payjesul 214 yum xoq uon unr 0 3 21 JUHM 11 32V18 n ury 915 d aqe2 L_ sam UONEWUOJU He3su SOES LETHOMY yymynssd 2460 Jad 1342319 yn ssa 10 d lyoz od 2 40 lqe 1 2 12 YUeIq Jad Pyn ssa d lyog od 2 ui ii D 29 28 DARFON Manufactured by ml DARFON ELECTRONICS CORP 167 Shan ying Road Gueishan Taoyuan 333 Taiwan R O C Tel 886 3 2508800 www DARFON com US Office Darfon America Corp 3031 Tisch Way STE 610 San Jose CA 95128 Tel 1 408 260 3880 30