1. nterference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment 13 14 NOTES LIMITED WARRANTY Alarm Device Manufacturing Company a Division of Pittway Corporation and its divisions subsidiaries and affiliates Seller 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product or for products not having an Ademco date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Ademco factory service For warranty se
2. Provides Comfort and Convenience Heat or air conditioning in vacation homes can be remotely set and monitored by phone For example heat can be turned up at a ski cabin before guests arrive The owner can also call in to the system to check that the indoor temperature is being maintained while the premises are vacant Users can set the air conditioning by calling home just before leaving work Once access to the security system has been established the ambient temperature will automatically be announced if the installer has programmed this function The following sections describe how to use the Ademco thermostat How the Ademco Thermostat Works With Your Present Thermostat The Ademco thermostat works in combination with the original thermostat installed on the premises Whilethe premises is occupied the security system is usually armed STAY or DISARMED and the Ademco thermostat will be inactive Theoriginal thermostat can be used as usual to set and adjust your premises temperature When controlling a heating system the set back temperature setting of the Ademco thermostat must always be set to a lower temperature than the original thermostat This way the Ademco thermostat will turn down the heat when the security system is ARMED AWAY Alternately when controlling an air conditioning system the set back temperature setting of the Ademco thermostat must always be set to a higher temperature than the original thermostat This way
3. T m Ts 15 About the Ademco Thermostat The Ademco thermostat provides control for both heat and air conditioning It is intended for use with Ademco security systems that include the enhanced 4286 phone module You can set the Ademco thermostat using any Touch tone phone either on premises or remotely The Ademco thermostat is not a replacement for the existing thermostat which remains in the installation but can be selected to provide a set back function whenever the system is in the ARMED AWAY mode The existing thermostat controls premises temperature while the security system is DISARMED or in the ARMED STAY mode Saving Money on Energy Bills An important benefit of combined climate control and security is potential energy cost savings During the heating season you can set back the Ademco thermostat for times when you are away from home by putting the security system in the ARMED AWAY mode Our set back feature lets you turn down the thermostat when the house is empty automatically when you arm the security system in the ARMED AWAY mode During the cooling season you can set the Ademco thermostat for a higher temperature than the existing thermostat for times when you are away from home to save on cooling costs by putting the security system in the ARMED AWAY mode In both cases you can call home to adjust the set back temperature that is in effect while the system is in the armed away mode The Ademco Thermostat
4. should be selected with this switch and the setting should not be changed 2 ACTIVE BYPASS Switch This switch is used to activate and deactivate the Ademco thermostat When this switch is set to the ACTIVE mode the Ademco thermostat is able to set back the room temperature when the security system is ARMED AWAY BYPASS is used to bypass the Ademco thermostat When bypassed the Ademco thermostat cannot change the room temperature You will not be able to adjust room temperature by phone when the Ademco thermostat front panel switch is in BYPASS position There are several uses for the BYPASS switch function e Allows the user to go back to their original thermostat at any time e Allows heating air conditioning service people to bypass the Ademco thermostat during servicing and maintenance work e Allows switching back to the original thermostat if the security system is not working or is being serviced 3 Front Panel Controls cont d 3 ACTIVE BYPASS Controls Indicator This yellow LED indicator shows the status of the Ademco thermostat e When the ACTIVE BYPASS switch is in the ACTIVE position the LED will be steadily on e When in BYPASS the LED will be steadily off If there is a problem with the wiring to the Ademco thermostat the LED will flash and you should call your alarm installation or service company for service Product Specifications Operating Range 32 to 122 degrees F O to 50 degrees C Te
5. statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to compl y with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the receiver away from the security control Move the antenna leads away from any wire runs to the security control Plug the security control into a different outlet so that it and the receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful
6. ALIEMCU 4500 THERMOSTAT USER GUIDE HOW TO e SAVE ENERGY WHILE AWAY FROM HOME e ADJUST ROOM TEMPERATURE BY PHONE READ THIS ENTIRE THERMOSTAT USER GUIDE BEFORE USING THE ADEMCO THERMOSTAT N 7972 7 97 Table of Contents About the Ademco Thermo 1 Saving Money on Energy BillsS nr 1 The Ademco Thermostat Provides Comfort and Convenience l How the Ademco Thermostat Works with Y our Present Thermostat 2 Front Pana Controls and Indicator az 3 Product SPECCAEIONS ovatie ds 4 Controlling the Ademco Thermostat by Phone s 5 To Enter the Thermostat M ode Menu by Phone 5 Adjusting the Set Back Temperature of the Ademco Thermostat 6 Tarmo tese Bak On and Off arten tto t nter coat o put vite ur t ers ra vu uas 8 Using Two Ademco Thermostats with Your System 9 When Leaving Protected Premises for Extended Periods 10 Testing the Heating Cooling System eese 11 Testing the Pre existing T hermostat a r 12 Federal Communications Commission F CC Pakt T5 S Cal EEE non nT Per eee er eee ne eee es 13 IN OLES raand case card da ede daa EE 14 EME Wa I ran
7. At this point you have adjusted the set back temperature and the new setting has been echoed back Your options now are e to wait for the menu to be announced again in case you want to review or change the thermostat settings e tojust hang up the phone Turning the Set Back On and Off The set back feature of the Ademco thermostat works automatically when you leave the premises and the security system is ARMED AWAY However sometimes you may want to override this feature You can turn off the set back at any time while still on the premises or off For example on a very hot day you may want the premises temperature to be restored to the more comfortable normal settings by the time you return home from work instead of remaining at the more economical set back temperature until you arrive You would do the following 1 Call the security system before returning home 2 Enter your 2 digit phone code and 4 digit user code as requested by the system Press 9 9 to enter the Thermostat Mode Menu 4 Atthe To Turn Set Back Off Enter 3 prompt press This command temporarily deactivates the set back function until you return home 5 You can exit the Thermostat Mode at this point by pressing o at the exit prompt 6 The premises cooling system will now be under the original thermostat s control with the premises temperature being lowered to the more comfortable setting When you turn off the set back you are on
8. LL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warranties and is the only warranty made by Seller on this product Noincrease or alteration written or verbal of the obligations of this Limited Warranty is authorized 15 ADEMCO GROUP 165 Eileen Way Syosset New York 11791 Copyright O 1997 PITTWAY CORPORATION N 7972 7 97
9. Press to select Thermostat 2 Y ou will hear the operating mode and set back temperature for Thermostat 2 N ext you can change its settings by waiting for the thermostat menu and pressing 1 after the To change temperature enter 1 prompt Y ou can then review and change the set back temperature in effective in the ARMED AWAY mode as described earlier in Setting the Ademco Thermostat on page 5 of this manual When Leaving Protected Premises for Extended Periods 10 We recommend that the 4500 Ademco thermostat the original thermostat and the entire heating cooling system be tested weekly and always before leaving the premises for extended periods of time such as during vacation time If you live in an area where temperatures can be extreme it is important to dial into your security system periodically as described earlier while away to monitor premises temperatures Follow procedures detailed on page 5 to hear ambient temperature status and on page 6 for making changes to the set back settings in the thermostat program mode If the heating air conditioning control system electric power or security system fails you can call for service before any problems occur If any one of those systems fail it could result in failure of the heating cooling system to maintain room temperature Failure of the heating or cooling system could result in property damage or injury It is important to maintain your security and h
10. as follows e THERMOSTAT MODE followed by whether SET BACK is ON or OFF and whether the Ademco thermostat is set for HEAT MODE or COOL MODE e thetemperature setting of the Ademco thermostat that is in effect when the security system is ARMED AWAY A menu of thermostat related end user commands will be annunciated The following sections Adjusting the Set Back Temperature of the Ademco Thermostat Turning the Set Back On and Off Using Two Ademco Thermostats With Your Security System and Exiting Thermostat Mode explain the use of the thermostat mode commands Adjusting the Set Back Temperature of the Ademco Thermostat Keep in mind that the on premises existing thermostat is set to the desired temperature for when the building is occupied The Ademco thermostat is used to set the set back temperature for when the premises is unoccupied and the security system is in the ARMED AWAY mode The Ademco thermostat is set from any T ouch tone phone either on premises or by calling in when away 1 Make sure that the front panel switches on the Ademco thermostat are set correctly e TheACTIVE BYPASS switch must be set to ACTIVE and e TheHEAT COOL switch must be set for the desired mode of operation Enter thermostat mode as described on page 5 A menu of user commands will be announced When you hear the prompt To change temperature enter 1 Press during a pause in the thermostat mo
11. de menu announcement The system will announce Temperature set to 65 for example Next it will announce Enter new temperature If you want to keep the present set back temperature 65 degrees in this example just press f you want to change the set back temperature point you can then enter a new temperature 6 for example Y ou have now set your unoccupied premises temperature to 61 degrees The system will then announce the change of set point Setting the Set Back Temperature of the Ademco Thermostat cont d 6 The new ARMED AWAY set back temperature point will be announced This is the temperature the Ademco thermostat will maintain when you are away from the premises The set back is turned on only when the security system s ARMED AWAY The system will announce Armed away temperature set to 61 7 Next it will repeat Enter new temperature If you want to keep the present set point 61 degrees in this example just press If you make an out of range temperature setting a buzzer sound will indicate to you that you made a mistake and you will be prompted again to enter the desired set point You have now set your ARMED AWAY temperature to 61 in this case and the phone module will echo back the change to verify 8 If you are all done with the settings and now want to arm or disarm the security system wait for the To exit enter zero menu announcement and press 0 9
12. eating cooling systems and to periodically test your security system and heating cooling system to insure proper operation Testing the Heating Cooling System To be sure the heating cooling system is maintaining the room temperature at the set back point you have programmed by phone test the system as follows 1 Be sure that the Ademco thermostat is in the ACTIVE mode using its front panel slide switch Refer to page 3 if in doubt 2 Be surethat the ACTIVE LED turns on and is not flashing e A flashing LED indicates a problem with the wiring to the Ademco thermostat e A Check Thermostat announcement on the phone is also an indication to call for servicing of the Ademco thermostat 3 Armthe security system in the ARMED AWAY mode and leave the premises When you return home or by calling home while away verify that the temperature inside the premises closely matches the set back point initially programmed Be surethat sufficient time has been allowed for the premises ambient temperature to stabilize If the Ademco thermostat is not maintaining temperature as was programmed first review the ARMED AWAY set back point using the phone and then check if the pre existing thermostat is working as described in the next section If both thermostats are not working call your heating air conditioning service company for servicing of your system If only the Ademco thermostat is not working properly immediately set its front pane
13. l switch to BYPASS thereby using the pre existing thermostat to control your heating and cooling system and call your alarm installation or service company for service 11 Testing the Pre Existing Thermostat 12 Switch the front panel ACTIVE BYPASS switch to BYPASS and check that the pre existing thermostat not the Ademco thermostat is working and able to control the heating cooling system If the pre existing thermostat does not function have it replaced or call your heating or air conditioning service company If you need service for your security system or heating air conditioning system If your security system or heating air conditioning systems are in need of service set the Ademco thermostat to the BYPASS mode using the front panel ACTIVE BYPASS switch When bypassed the Ademco thermostat s totally removed from control of the heating and or air conditioning systems The pre existing original thermostat will then maintain total control of the heating and or air conditioning systems When the Ademco thermostat is bypassed it will be easier for heating air conditioning service personnel to service those systems including their respective control systems The switch may be restored to the ACTIVE position when the servicing is completed FEDERAL COMMUNICATIONS COMMISSION FCC PART 15 STATEMENT This equipment has been tested to FCC requirements and has been found accept able for use The FCC requires the following
14. ly doing so temporarily When you return home the thermostat mode menu resets itself automatically so that when you again exit the premises with the security system in the ARMED AWAY state the premises temperature will go to the programmed Ademco thermostat setting In the example above if you change your mind and decide not to return home early you can turn the thermostat set back to on again by phone Using Two Ademco Thermostats with Your Security System If your security system includes two Ademco thermostats and you have a multi zone heating or air conditioning system you can set the heat and air conditioning at different temperatures in different parts of the house In order to program the thermostats you must obtain access to the security system and then the Thermostat M enu M ode Refer to the section To Enter the Thermostat Menu Mode on page 5 or perform the first three steps of the abbreviated step by step procedure on page 8 and continue with this procedure Thetwo thermostats in your system are named Thermostat 1 and Thermostat 2 for programming purposes When you first enter Thermostat menu mode you are hearing status for Thermostat 1 and you can adjust the set point for Thermostat 1 without having to LOG ON f however you want to review or set Thermostat 2 you must first choose the Log On menu selection At the To log on enter 2 prompt press The System will announce Enter thermostat number
15. mperature Setting Range 45 to 99 degrees F 7 to 37 degrees C Temperature Reading Accuracy 2 degrees F 1 degree C Air Conditioner Compressor Off Cycle 5 minutes minimum Physical Dimensions 6 3 16 by 2 7 8 by 1 1 4 Controlling the Ademco Thermostat by Phone The phone access feature of the Ademco security system provides a number of capabilities to the user e Toagjust the ARMED AWAY set back temperature of the Ademco thermostats over any phone e Toturn off the set back function for a single ARMED AWAY period or turn it on again if necessary e Tocontrol two Ademco thermostats in a single installation A Thermostat Mode voice menu can be activated after accessing the security system by phone To Enter the Thermostat Mode Menu By Phone 1 Obtain access to your security system by phone according to the instructions for phone access provided with your security system Y ou will need to enter the 2 digit phone code provided by your installer and your 4 digit user code when you are calling from outside or whenever prompted by the system 2 You will now hear the announcement of the security system status followed by the ambient room temperature if installer has programmed this particular option 3 Wait until the security system completes the status announce ments When prompted by the system press 9 9 The security system phone access module will announce all words denoted by quotation marks and italicized
16. rvice return product transportation prepaid to an authorized Ademco Distributor THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the products it sells may not be compromised or circumvented that the products will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the products will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHA
17. the Ademco thermostat will allow the ambient temperature to rise when the security system is ARMED AWAY If the pre existing thermostat has a built in clock and schedule the schedule can be used to set the times you wake leave return and sleep Note The leave time should be set for the latest time that you would expect to leave the premises The return time should be set to the earliest time you expect to arrive at the premises If you leave earlier or return later than scheduled times the Ademco thermostat will adjust the temperatures accordingly In summary the ADEM CO thermostat allows you to e Set back the temperature to that set in the ADEM CO thermostat automatically by arming in the AWAY mode when leaving home e Resume normal temperature as set by the existing thermostat automatically by DISARMING the system when returning home e Check the temperature by phoning in from a remote location Front Panel Controls As you can see from Figure 1 below there are two controls and one indicator on the front panel of the Ademco thermostat HEAT lt gt COOL BYPASS lt gt ACTIVE Figure 1 4500 Thermostat Controls and Indicator 1 HEAT COOL Switch This switch s used to set the control mode of the Ademco thermostat The mode can be set to either HEAT or COOL This is the same as found on most thermostats For premises that only have heat or air conditioning but not both the proper mode

Download Pdf Manuals

image

Related Search

Related Contents

DT-SAM User`s Manual - Datatek Applications  Potter Nitrogen Generator - Complete Plumbing Source  Milo  2 Bedienung    Allgemeines - eService Staging Server  Handbuch pdf, 224 KB - BUCK Elektromedizin  Instructions for Use Important Note Please read these  Surface Control Manager User Manual  Samsung E330 User's Manual  