1. by DipBCD DipBCD RS1 100 all Red level 0 9 9 100 Red DipBCD RS2 10 all Green level 0 9 9 100 Green DipBCD RS3 1 all Blue level 0 9 9 100 Blue MMxX Leader Light All right reserved RIGIBIAWIN 1x 0 35 0 35A RIGIBINWIN 1x 0 70 0 70A RIGIB AWIN 1x 1 40 1 40A LL LED TopLED RGB 3x 0 02 0 06A RGBW 4x 0 02 0 08A l E RGBAW 5x 0 02 0 10A 70 LL ARC Point Splitter 6 x point RGB AWB 3x 0 35 1 05A R A G B W N 1x 0 35 0 35A 6x4 6x12 6x4 6x12 A current for 1 colour Recommended power supply by Leader Light MW 240 24 only 10A y y 1 4 1 4 1 4 141414 1 4 70 70 6x4 6x12 vy 1 4 1 4 1 4 4x RGB 3x RGBW 2x RGBAW maximum fitting amound per LLARC DRIVER 15 max 16A 7 max 16A 3 max 16A 45 max 16A 22 max 16A 11 max 16A zo 266 max 16A 200 max 16A 140 max 16A 15x6 max 16A 45x6 max 16A Note Numbers in table indicate maximum number of the luminaries which can be connected to individual outputs for each LL ARC POINT RGB AWB R A G B W N use special type of LL ARC POINT SPLITTER Connection conditions The maximum allowable current for whole DRIVER is 16A The maximum allowable current per output is 1 4 A Do not operate with more luminaries than the maximum permitted number stated in Table 1 1 LL ARC DRIVER is designed primarily for LL LED products Amound of ch
2. output 24V DC 4 output groups Control data Protocol USITT DMX 512 or RS 423 232 LL defined protocol Ambient temp Ta 0 C 40 C Net weight 1 0 kg Dimensions LxWxH 107mm x 105 4mm x 79mm Installation standard DIN installation TS35 6DIN Edition A 2010 02 2 Product description pip DC 24V settings power Control data Rotating DIP Control 6pin line conector 100 10 1 LEDs E E Mo Ea E aay ov E DMX 512 DIP CHANNELS POWER E RS 423 232 MODE amp ADDRESS INPUT D G E G S G S G E G E G E G E G E A E G E G E G E E S CEARGORYET sales leaderlight eu A a cE DC 24V INPUT T 40 C MAX 16A m G m G m G m G m G a G a G n G n G a G n G a G n GROUP 1 GROUP 2 GROUP 3 GROUP 4 RAN RENN A VEN E N 12x LED PWM output 4 groups 4x 6pin line conector Indication of control LEDs LED power green LED data yellow LED Indication Status LED Power blinking 2Hz O K device is working correct LED Data not lit No DMX signal LED Data blinking 4Hz O K Connected the correct DMX signal LED Data fast blinking ERROR incorrect digital signal aie i aae function AutoTest 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valua
3. 6 channel 7 channel 8 channel 9 channel 10 Features Dip Dip4 Off Dip1 Off DipBCD 9xx DipBCD 8xx Dip1 On Dip4 On Dip2 Off Dip3 Off Dip2 Off Dip3 On Dip2 On Dip3 Off Dip2 On Dip3 On Mode 2 DIP2 Off and DIP3 On S R GBA W V R GBA W tV R G B W V R GB V Group 1 Group 2 Group 3 Group 4 YYY vy vYV YY 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 LL ARC LINE L A RGB AWB 3x 0 35 1 05A RGB AWB 3x 0 70 2 10A RGB AWB 3x 1 40 4 20A OneColour Red 1 channel 1 Red 1 Green 1 channel 2 Green 1 Blue 1 channel 3 Blue 1 Red 2 channel 4 White 1 Green 2 channel 5 Red 2 Blue 2 channel 6 Green 2 Red 3 channel 7 Blue 2 Green 3 channel 8 White 2 Blue 3 channel 9 Red 3 Red 4 channel 10 Green 3 Green 4 channel 11 Blue 3 Blue 4 channel 12 White 3 Mode 4 DIP2 On and DIP3 On Red 1 Manual Mode Green 1 Blue 1 Amber 1 White 1 Red 2 Green 2 Blue 2 Amber 2 White 2 gt DipBCD Rotary switch for setting DMX address RS1 100 RS2 10 RS3 1 from 001 to 512 Autotest gradual fade over RGB or RGBW or RGBAW by the Model AutoTest all channels on 50 Switch on Paralel mode parallel working groups 1 2 3 4 Switch on UltraSoft curve Mode 1 12 channels 4xRGB Mode 2 12 channels 3xRGBW Mode 3 10 channels 2xRGBAW Mode 4 4xRGB parallel controlled manually
4. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LEADER L GHT professional lighting products LL ARC DRIVER 12 LL42 100 COMPLIMENTS ON YOUR PURCHASE All dimensions are in millimeters 107 Package includes LLARC DRIVER12 1 pc 6pin line connector 5 pos User manual 1 pc Additional items needed Data and power cables 24V DC power supply Content 01 SAFETY INFORMATION 01 1 Safety instructions 01 2 Operating restrictions 01 3 Fire protection 02 PRODUCT SPECIFICATION 02 1 Technical specification 02 2 Product description 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Connection 03 4 Installation factors 03 5 DMX channels 04 MAINTENANCE AND SERVICE ENVIRONMENTAL PROTECTION Dad Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMX Leader Light All right reserved 01 SAFETY INFORMATION WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Installation can be done only by a qualified professional in accordance with relevant local codes 01 1 Safety instructions A Shut down power before installation or maintenance of equipment or voltage data source Do not modify alter
5. annels per LL ARC DRIVER12 4x RGB 12 channels 3x RGBW 12 channels 2x RGBAW 10 channels Group connection possibility Standard LL cable has following cable cores RGBAW Black or RGB Black Each colour is connected to corresponding colour In case AWB RGB Black AWB is connected to RGB Edition A 2010 04 MAINTENANCE AND SERVICE JN Before any maintenance is necessary to carefully read all SAFETY INFORMATION 01 Damages caused by inadequate cleaning or maintenance are not covered by warranty Requires periodic cleaning dust dirt Procedure for maintenance Unplug mains before maintenance and at least 10 minutes cool off Appliance do not illegal open or demount Clean up dust only from outer surface Use vacuum or dumpy duster warm water Before reinstalling make sure everything is intact and dry no wet parts Service Customer service provided by the manufacturer If you have any question please contact support leaderlight sk
6. ble for future claim 03 2 Physical installation Loading capacity of bearing area has to be at least 10 times the weight of all device clusters 03 3 Connection A Respect all SAFETY INFORMATION 01 Connect the ground earth to the bottom of the module LLARC DRIVER12 device may be operated only with 24V DC stabilized source Total input current is limited to max 16A In the case of connecting the power supply with more than a prescribed voltage you can suffer a dangerous electric shock inflict damage equipment or fire Shut down power supply from all devices before installation of LL ARC DRIVER12 to end devices Maximum number of connected LED luminaries to LL DRIVER12 ARC is shown in Table 1 1 If you have any question please contact support leaderlight sk 03 4 Installation Factors For any indoor and outdoor installation inside the installation box must be add 100mm to each side and must be add ventilation modul For outdoor installation must be add heating modul if the outdoor temperature is less then 0 C any time 03 5 DMX channels These informations are subject to change latest data are on www leaderlight eu Mode 1 DIP2 Off and DIP3 Off channel 1 channel 2 channel 3 channel 4 channel 5 channel 6 channel 7 channel 8 channel 9 channel 10 channel 11 channel 12 Mode 3 DIP2 On and DIP3 Off channel 1 channel 2 channel 3 channel 4 channel 5 channel
7. or attempt to service the LeaderLight appliance Doing so will void the warranty Use only the recommended DC voltage source Connect the ground to the bottom of the box Electrical connections service and maintenance can be performed only by qualified professional AC power supply of DC power supply must comply with local regulations AC power supply must be protected against overvoltage and short circuits 01 2 Operating restrictions This product is intended to operate only with Leader Light LED products This product was designed for indoor use only If the product has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your unit Leave the unit switched off until it has reached room temperature Do not operate the product in humid dusty or too hot cold environments Before connecting make sure the product is not damaged wet or otherwise damaged Unprofessional operation creates the most damages For transport use the original packaging Operate only with 24V DC stabilized source 01 3 Fire protection A Follow all safety restrictions Device never cover the minimum space around the vents must be at least 100mm 4 in Allowed maximum ambient temperature is 40 C 104 F 02 PRODUCT SPECIFICATION 02 1 Technical specification Power connection 24V DC max 16A Output 12x LED PWM