Home
VCL-V.35 Interface Fiber Optic Modem
Contents
1. 25 Male Connector 10 11 12 13 al Saeko 14 15 16 17 18 19 20 21 22 23 24 25 25 pin D type pin assignment view from FRONT side XV TR FDB Note This cable supplied with the modem Orion Telecom Networks Inc 2007 10 11 VCL V 35 Interface Fiber Optic Modem V 35 DCE Interface Cable V 35 DCE Interface Cable End 1 DB 25 Male End 2 V 35 connector Female Type of Cable Twisted pair cable solid conductor No of Pairs 9 Connection As per details given below DB 25 Male Signal on DB 25 Male Signal on V 35 V 35 Pin Source 1 Shelter Shelter A 14 Transmit Data Transmit Data S DTE 2 Transmit data Transmitter data P DTE 12 Transmit Timing Transmit Timing AA DCE 15 Transmit Timing Transmit Timing Y DCE 9 Receive Timing Receive Timing X DCE 17 Receive Timing Receive Timing V DCE 16 Received Data Received Data T DCE 3 Received Data Received Data R DCE 20 DTR DTR H DTE 6 DSR DSR E DCE 4 RTS RTS C DTE 5 CTS CTS D DCE 8 DCD DCD F DCE 7 Signal Ground Signal Ground B 24 Sending Clk A Sending Clk A U from DTE from DTE 11 Sending Clk B Sending Clk B W from DTE from DTE Orion Telecom Networks Inc 2007 10 12 VCL V 35 Interface Fiber Optic Modem Bottom View Bottom View Data Rate Selection for V 35 Interface Switches number 1 5 will be used for the data rate s
2. 35 Fiber Optic Modem 1310 nm VCL V35 FOM 1310 DC wavelength with DC power supply 5 VCL V 35 Fiber Optic Modem 1550nm VCL V35 FOM 1550 AC wavelength with AC power supply 6 VCL V 35 Fiber Optic Modem 1550 nm VCL V35 FOM 1550 DC wavelength with DC power supply Note Operation and maintenance of network equipment require professional knowledge and experience We recommend the equipment to be managed only by qualified technicians Should you require technical assistance please consult the provider or contact our SUPPORT DESK at support oriontelecom com Technical specifications are subject to changes without notice All brand names and trademarks are the property of their respective owners Revision 04 September 06 2010 Headquarters Phoenix Arizona Orion Telecom Networks Inc 20100 N 51stAve Suite B240 Glendale AZ 85308 Phone 1 480 816 8672 Fax 1 480 816 0115 E mail sales oriontelecom com Website http www oriontelecom com Regional Office Miami Florida Orion Telecom Networks Inc 4000 Ponce de Leon Blvd Suite 470 Coral Gables FL33146 U S A Phone 1 305 777 0419 Fax 1 305 777 0201 E mail sales oriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2007 10 16
3. 6nm Average Output Power 15dBm 12dBM 8dBm Output Optical Eye Complaint with ITU T G 957 Connectors FC Receiver Optical Characteristics Parameter Minimum Typical Maximum Data Rate 125Mb s Receive Sensitivity 32dBm Maximum Input Power 15dBm Operating Wavelength 1100nm 1600nm Connectors FC Optical Interface Specifications 1510nm Single Mode Transmitter Optical Characteristics Parameter Minimum Typical Maximum Data Rate 125Mb s Center Wavelength 1480nm 1550nm 1580nm Output Spectral Width RMS 4nm Average Output Power 15dBm 12dBM 8dBm Output Optical Eye Complaint with ITU T G 957 Connectors FC Receiver Optical Characteristics Parameter Minimum Typical Maximum Data Rate 125Mb s Receive Sensitivity 32dBm Maximum Input Power 15dBm Operating Wavelength 1100nm 1600nm FC Connectors Orion Telecom Networks Inc 2007 10 VCL V 35 Interface Fiber Optic Modem Front View Front View Sane VCL V35 FOM ANA DIG REM PATT eooeoeene To 00o PWR TD RD OPLOS OPSYLPTOK TEST E OFF LED Indications S No LEDs Color Description 1 PWR Green ON indicates that input power supply is OK 2 TD Yellow Flashing LED indicated V 35 interface is transmitting data 3 RD Yellow Flashing LED indicated V 35 interface is receiving Data 4 OPLOS Red Optical link break alarm Solid RED indicates there is local alarm and flashing RED indicate there is an alarm at the remote end AIS 5 OPSYL Red No frame
4. JRION NETWORKS VCL V 35 Interface Fiber Optic Modem User Manual VCL V 35 Interface Fiber Optic Modem Notice Warranty This Orion product is warranted against defects in material and workmanship for a period of one year from the date of shipment During the warranty period Orion will at its discretion either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service facility designated by Orion The buyer shall prepay shipping charges to Orion and the company shall pay shipping charges to return the product to the buyer However the buyer shall pay all the shipping charges duties and taxes for products returned to Orion from another country Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the buyer the buyer supplied firmware or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance Exclusive Remedies The remedies provided herein are the buyer s sole and exclusive remedies Orion shall not be liable for any direct indirect special incidental or consequential damages whether based on contract or any legal theory Notice This manual contains information that is proprietary to Orion Telecom Networks Inc No part of this publication may be reproduced in any form wh
5. atsoever without prior written approval by Orion Telecom Networks Inc Safety Warnings The exclamation point within a triangle is intended to warn the operator or service VAN personnel of operation and maintenance factors relating to the product and its operating environment which could pose a safety hazard Always observe standard safety precautions during installation operation and maintenance of this product Only qualified and authorized service personnel should carry out adjustment maintenance or repairs to this instrument No adjustment maintenance or repairs should be performed by either the operator or the user s NES ASSURANCE PROGRAM Orion s products are designed and manufactured under a strict Quality Assurance Program based on the ISO 9000 2008 philosophy and principles Orion pays very special attention to its vendor development program which ensures an end product of the highest quality at the most cost effective prices Orion Telecom Networks Inc 2007 10 2 VCL V 35 Interface Fiber Optic Modem Index INDEX Particulars P No Product Overview 4 Application Diagram 4 Technical Specifications 5 V 35 Interface 5 Optical Interface Specifications 850nm Multi Mode 5 Transmitter Optical Characteristics 5 Receiver Optical Characteristics 5 Optical Interface Specifications 1310nm Single Mode 6 Transmitter Optical C
6. ber V35 Optic Modem Network Optic Modem V 35 Router V 35 Router Orion Telecom Networks Inc 2007 10 4 VCL V 35 Interface Fiber Optic Modem Technical Specifications Technical Specifications V 35 Interface Interface type V 35 Interface mode DCE Interface bit rate nx64 Kbps n 1 32 Connector DB 25 Female Adapter DB 25 Male to M34 Winchester Female Optical Interface Specifications 850nm Multi Mode Transmitter Optical Characteristics Parameter Minimum Typical Maximum Data Rate 125Mb s Center Wavelength 830nm 850nm 860nm Output Spectral Width RMS 0 85nm Average Output Power 10dBm 3dBm Output Optical Eye Complaint with ITU T G 957 Connectors FC Receiver Optical Characteristics Parameter Minimum Typical Maximum Optical Data Rate 125Mb s Receive Sensitivity 24dBm Maximum Input Power 3dBm Operating Wavelength 10dBM 850nm Connectors FC Orion Telecom Networks Inc 2007 10 VCL V 35 Interface Fiber Optic Modem Technical Specifications Optical Interface Specifications 1310nm Single Mode Transmitter Optical Characteristics Parameter Minimum Typical Maximum Data Rate 125Mb s Center Wavelength 1260nm 1310nm 1360nm Output Spectral Width RMS
7. ce VCL V 35 Fiber VCL V 35 Fiber A 2 Optic Modem Optic Modem Local End Remote End PATT This switch initiates a data link integrity test by generating a pseudo random pattern Important All switches must be in OFF condition during normal operations Whenever a test switch is used to initiate a test the normal communications shall be disrupted When PATT switch is used to do a data link integrity test please ensure that the far end in a loopback mode to complete the test circuit Orion Telecom Networks Inc 2007 10 8 VCL V 35 Interface Fiber Optic Modem Rear View Rear View AC Power Supply 3 Pin male Socket Ate Source 220V Tx Rx GNSS A8v aN9A 8 Note Please connect 48V DC supply to the system as shown in above figure Orion Telecom Networks Inc 2007 10 9 VCL V 35 Interface Fiber Optic Modem Optical Connection Optical Connection AC 220V 10n Transmit Receive Optical Signal Optical Signal through Optical through Optical Fiber Cable Fiber Cable Note Do not expose to the naked eye Connect fiber cable to system when power is OFF Orion Telecom Networks Inc 2007 10 10 VCL V 35 Interface Fiber Optic Modem V 35 Connection V 35 Connection o OFF O ON AC 220V DB 25 Female Connector DB 25 Male Connector V 35 Winchester Female Connector M 34 Winchester Female DB
8. election of V 35 Refer the following table for different data rate selection of V 35 Interface Switch Switch Switch Switch Switch Data Rate of V 35 No 1 No 2 No 3 No 4 No 5 Interface Kbit s OFF OFF OFF OFF OFF 64 ON OFF OFF OFF OFF 128 OFF ON OFF OFF OFF 192 ON ON OFF OFF OFF 256 OFF OFF ON OFF OFF 320 ON OFF ON OFF OFF 384 OFF ON ON OFF OFF 448 ON ON ON OFF OFF 512 OFF OFF OFF ON OFF 576 ON OFF OFF ON OFF 640 OFF ON OFF ON OFF 704 ON ON OFF ON OFF 768 OFF OFF ON ON OFF 832 ON OFF ON ON OFF 896 OFF ON ON ON OFF 960 ON ON ON ON OFF 1024 OFF OFF OFF OFF ON 1088 ON OFF OFF OFF ON 1152 OFF ON OFF OFF ON 1216 ON ON OFF OFF ON 1280 OFF OFF ON OFF ON 1344 Orion Telecom Networks Inc 2007 10 13 VCL V 35 Interface Fiber Optic Modem Phase setup of V 35 Interface Switch Switch Switch Switch Switch Data Rate of V 35 No 1 No 2 No 3 No 4 No 5 Interface Kbit s ON OFF ON OFF ON 1408 OFF ON ON OFF ON 1472 ON ON ON OFF ON 1536 OFF OFF OFF ON ON 1600 ON OFF OFF ON ON 1664 OFF ON OFF ON ON 1728 ON ON OFF ON ON 1792 OFF OFF ON ON ON 1856 ON OFF ON ON ON 1920 OFF ON ON ON ON 1984 ON ON ON ON ON 2048 Phase setup of V 35 Interface Switches number 6 7 will be used for setting the phase relationship of transmit and receive data and sending and receiving clocks
9. for V 35 Interface It may be necessary to use this adjustment if the V 35 communication fails to start Switch No 6 Switch No 6 Phase setup V 35 Interface ON ON The falling edge of the clock of V 35 Interface is used for transmit and receive data OFF OFF The rising edge of the clock of V 35 Interface is used for transmit and receive data Orion Telecom Networks Inc 2007 10 14 VCL V 35 Interface Fiber Optic Modem Clock Selection Clock Selection Switches number 8 9 will be used for selection of synchronization clock Switch No 8 Switch No 9 Synchronization Clock Settings ON OFF System will work on its internal clock OFF OFF System will work loop timed clock from the equipment which is connected on V 35 Interface side ON ON System will work loop timed clock from the equipment which is connected on optical side Switch number 10 will be unused and always be set on OFF condition Orion Telecom Networks Inc 2007 10 15 VCL V 35 Interface Fiber Optic Modem Ordering Information Ordering Information Sr No Product Description Part No 1 VCL V 35 Fiber Optic Modem 850 nm VCL V35 FOM 850 AC wavelength with AC power supply 2 VCL V 35 Fiber Optic Modem 850 nm VCL V35 FOM 850 DC wavelength with DC power supply 3 VCL V 35 Fiber Optic Modem 1310 nm VCL V35 FOM 1310 AC wavelength with AC power supply 4 VCL V
10. haracteristics 6 Receiver Optical Characteristics 6 Optical Interface Specifications 1510nm Single Mode 6 Transmitter Optical Characteristics 6 Receiver Optical Characteristics 6 Front View 7 LED Indications 7 Pushbutton and Switch Indications 8 Rear View 9 AC Power Supply 9 48V DC Power Supply 9 Optical Connection 10 V 35 Connection 11 V 35 DCE Interface Cable 12 Bottom View 13 Data Rate selection for V 35 13 Phase setup of V 35 Interface 14 Clock Selection 15 Ordering Information 16 m CAUTION vA ELECTROSTATIC A SENSITIVE DEVICES v DO NOT OPEN OR HANDLE A A EXCEPT ATA STATIC FREE WORKSTATION Orion Telecom Networks Inc 2007 10 3 VCL V 35 Interface Fiber Optic Modem Product Overview Product Overview The VCL V 35 Fiber Optic Modem provides the user the capability to establish communication between Qro two V 35 interfaces or N 64 Kbps fractional V 35 Rai VOLVSEFOM AA OE REUEN over an optical fiber link eB EE oN omt ee 000o It establishes a secure long range data fiber link between computers routers multiplexers and other VCL V 35 Interface V 35 data communication devices Fiber Optic Modem The primary application for the VCL V 35 Fiber Optic Modem is to establish point to point fiber link at ranges longer than any copper modem can achieve The clock options are Internal External Slave Clock three clock mode option Application Diagram VCL V 35 Fiber Optical VCL V 35 Fi
11. synchronization code is detected in the input signal of optical interface Solid RED Indicates an alarm of local end and flashing to indicates there is an alarm at the remote end 6 PTOK Green Pseudo code normally detected 7 TEST Yellow Local device or remote device in test mode Orion Telecom Networks Inc 2007 10 7 VCL V 35 Interface Fiber Optic Modem Push button and Switch Indications Push button and Switch Indications Four push button switches are available on the front panel The switches are in ON mode when pressed and in OFF mode when released ANA This switch initiates a internal loopback on the optical interface so that the V 35 data being received from Tx Pins of V 35 interface by the system is transmitted back to the Rx Pins of the V 35 Interface This test may be used to verify the integrity of the V 35 data interface connections VCL V 35 Fiber V 35 Optic Modem Optical dhl DIG This switch initiates a internal loopback on the V 35 Interface so that the data being received from the Tx Pins of optical fiber is sent back on the Rx Pins of optical fiber through the V 35 Interface This test may be used to verify the integrity of the optical link a VCL V 35 Fiber V 35 Optic Modem Optical Interface REM This switch initiates a loopback at the remote side It may be used to verify the complete data link integrity between the local and the remote V 35 Interfa
Download Pdf Manuals