Home
Quick Read Technology Blood Pressure Monitor
Contents
1. ith the touch of a butt and hold the START STOP button again een a anise After 3 beeps all records have been deleted Memory Recall Installing the Batteries To see the previously measured values To insert the batteries A Press down on the latch and lift the cover toward you to A Press the MEMORY button to recall the last reading The open the battery compartment LCD display will show the memory number actual date and time of the measurement B Insert 4 AA batteries as indicated Make sure to match polarities on the batteries C Replace the battery cover by inserting the two hooks at the bottom into the slot then push on the top area Memory MEMORY ui leu Memory Number gt NO cu Note Please remove batteries when not in use for an extended Be 19 period of time Do not dispose batteries with household garbage v wo MEMORY Date gt 1 14 ieg Ge 8 MEMORY Time gt 15 13 iep be 8 B To view additional readings push the MEMORY button successively to go through the various readings 1 85 EA Es Correct Measuring Posture Measurement Procedures C Quick Read Technology detects your blood pressure with the touch of a button which reduces measurement time significantly and decreases patient discomfort A Place your elbow on a table so that the cuff is at the same level as your heart Note The level of your heart is sligh
2. show a flashing 0 B After the 0 stops blinking the unit will automatically dats C Remove any clothing that restricts your upper left arm inflate to the appropriate inflation level based on the i illati M enill thon baai Wrap the cuff around your upper left arm The rubber aa a R a a eee tube should point in the direction of your hand Position the artery mark over the main artery on the inside of your arm in the upper arm 1 31 p Flashing 0 Initial Display Applying the Cuff D Turn your left palm upward and place the edge of the arm cuff at approximately 1 2 inches above the inner side of the elbow joint Tighten the cuff by pulling the end of the cuff 2 3 cm 0 8 1 2 Ni E If the Index line falls within the OK range indicated at the edge of the cuff this cuff is suitable for your use If the Index line falls out of the OK range you may need a special cuff for measurement Please contact our service department at 1 800 672 8293 for more information regarding additional cuffs Note To locate the main artery press two fingers approximately 1 2 inches above the bend of your elbow on the inside of your left arm Helpful Tips Here are a few helpful tips to help you obtain a more accurate reading A Do not measure your blood pressure immediately after consuming a large meal To obtain more accurate readings please wait one hour before me
3. 3 are equivalent to those obtained by a trained observer using cuff stethoscope auscultation method within the limits prescribed by the American National Standard Electronic or Automated Sphygmomanometers Please read this manual carefully before use For specific information on your own blood pressure contact your physician Please be sure to keep this manual Specifications Model 1133 Display System Liquid Crystal Display Power source 4 AA Alkaline batteries Measurement Method Oscillometric Measurement Range Pressure 20 300 mmHg Pulse 40 200 beats minute Accuracy Pressure 3 mmHg Pulse within 5 of reading Inflation Micro rolling Pump Pressure Exhaust Electrical Solenoid Valve Memory 85 sets Low Battery Indicator Yes Auto shut off 2 5 minutes after last key operation Battery Life 250 operations Operating Environment 50 F 104 F 10 C 40 C lt 85 RH Storage Environment 4 F 122 F 10 C 50 C lt 85 RH Weight 82 lb 375g with batteries Arm circumference 8 5 14 in 216 356 mm Dimensions LxWxH 5 5 x 3 9 x 2 9 in 140 x 99 x 74 mm Specifications are subject to change without notice E E Troubleshooting Message Correction The pressure measured was lower than 20 mmHg Solution Please measure again The pressure measured was higher than 300 mmHg Solution Please measure again Pumping error Solution Plea
4. Distributed by GF Health Products Inc www grahamfield com Made and Printed In China LUMISCOPE A Graham Field Brand Quick Read Technology Automatic Blood Pressure Monitor Model 1133 User Manual 1133 INS LAB RevA08 Two Year Limited Warranty GF Health Products Inc guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase except as noted below This product warranty does not cover damage caused by misuse or abuse the attachment of any unauthorized accessory alteration to the product or any other conditions whatsoever that are beyond the control of GF Health Products Inc GF Health Products Inc shall not be responsible for any type of incidental consequential or special damage All implied warranties including but not limited to those implied warranties of fitness and merchantability are limited to the total duration of two years from the original date of purchase To obtain warranty service on your Blood Pressure Monitor please contact our Repair Department at 1 800 672 8293 There is a 15 fee for return shipping and handling please make checks payable to GF Health Products Inc Upon receipt GF Health Products Inc will repair or replace as appropriate this blood pressure monitor and return it to you Service of this product by anyone other than GF Health Products Inc voids warranty Table of Contents I
5. START STOP button to adjust the values of the MONTH DATE HOUR and MINUTE when they are blinking 1 START STOP 4 Arm Cuff 2 Memory Select 5 LCD Display 6 AC Adapter Connection 3 Air Tube optional SSS EEE _ Display Symbols amp Explanations Deleting the Memory To delete the memory Display Symbols 1 To delete one memory wo Q amp vemory DOM A Press the MEMORY button to display the A Ww record that you wish to delete mouc Flee ic ta f Jn ft Systolic Pressure B Press and hold the START STOP button qp lt m qr lt until the display shows DEL JIE bos MEMORY Diastolic Pressure Pama mm df 5 Pulse Rate C Once the DEL has been displayed press and hold the Display Explanations START STOP button again After 3 beeps the selected Low Battery Indicator Appears when the record Nae Been ABEBA batteries are low or need replacement 2 To delete all memories Follow steps A and B above Pulse Symbol Shows the pulse rate per minute l f the MEMORY butt til the displ Memory Holds the memory for up to 85 readings C Press the ORY button until the display A Time Shows the time of each reading fol Date Shows the exact date month and day of M D each reading f D Once DEL ALL has been displayed press Quick Read Technology Detects your blood shows DEL ALL
6. asuring B Do not smoke or drink alcohol before measuring your blood pressure C You should not be physically tired or exhausted while taking a measurement D It is important that you relax during measurement Take a 15 minute rest before a reading E Do not take measurements if you are under stress or feeling tense F Take your blood pressure at normal body temperature G Ifthe monitor is stored at very low temperature near freezing place it in a warm location for at least one hour before using it H Wait about 5 minutes before taking the next pressure measurement E
7. miroduUCtON sieaa 3 About Blood Pressure c scccceeeeseseceeeeeseaeeeeeeseenees 4 5 Parts Identification sssrini derindir dina 6 Display Symbols amp Explanations 7 Installing the Batteries 0 ee eeceeeeeenneeeeeeeeneeeeeeenaae 8 Correct Measuring Posture eessen 9 Applying the Cuffs iiris uaiiie 10 11 FGI PTUl TipSseccccesieececencisecdeceherdecceconstneciccaninadictaberdecenstasd 12 Measurement Procedures ccccceesesseeeeeeseeeees 13 14 Memory Recall s ic ccccccssccicetesseececpesdecteceecdbetbeevessieectenss 15 Deleting the Memory sasssssssssrrenerrnensrrrnrnerinrnesrnennnnna 16 Clock Seting S s tungaane aa iaa 17 Care amp Maintenance ecccccecceeeeeeeeeeseeeeeeeeeeaeeeeenees 18 TROUDIESHOOUNG a 19 Specification S siesii sccoeseticdst ee cnctietiea adalat 20 Wan a saaie a tieatednaititedndibes 21 Introduction Congratulations on your purchase of the new Lumiscope Model 1133 This fully automatic blood pressure monitor is both easy to use and ideally suited for daily measurements The large display includes systolic blood pressure reading diastolic blood pressure reading and pulse rate all clearly shown at the completion of each reading You can store up to 85 measurements ideal for users who want to monitor and track their blood pressure on a regular basis The 1133 is compact and portable making it perfect for home use and travel Blood pressure measurements determined with your 113
8. se check cuff and try again The pressure can not be measured due to signal noise Solution Please measure again The pumping pressure is higher than 300 mmHg Solution Please measure again Low battery Solution Check and replace the 4 bat teries if necessary About Blood Pressure What is Blood Pressure Blood pressure is the pressure exerted on the artery tube while blood flows through the arteries The pressure measured when the heart contracts and sends blood out of the heart is systolic highest blood pressure The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic lowest blood pressure Why Measure Your Blood Pressure Among the various health problems afflicting people today problems associated with high blood pressure are by far the most common High blood pressure s dangerously strong correlation with cardiovascular disease has made measuring blood pressure a necessity for identifying those at risk About Blood Pressure Blood Pressure Standard The World Health Organization WHO and National High Blood Pressure Education Program Coordinating Committee have developed a blood pressure standard according to which areas of low and high risk blood pressure are identified This standard however is a general guideline and blood pressures vary between different people age groups etc It is important that you con
9. sult with your physician regularly Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk Grade 3 Hypertension Severe 180 2 Grade 2 Hypertension Moderate E 160 3 Grade 1 Hypertension Mild 2 140 3 High Normal gt 130 Normal 120 Optimal 80 85 90 100 110 Diastolic Pressure mmHg Care amp Maintenance Do not drop the unit It is not shockproof Do not modify or disassemble the unit or the arm cuff Use a cloth moistened with water or neutral detergent to clean the body of the unit Then wipe it dry Avoid thinner benzene and other harsh cleaners Keep the unit in a suitable place Avoid high temperature direct sunlight high moisture and dust Remove the batteries if the unit will not be used for a long time Clock Settings Parts Identification Setting the Clock Date amp Time A Press and hold the MEMORY button for at least 3 seconds The display will eg g5 show a blinking year Press the START STOP button to adjust the year when it s blinking B Press the MEMORY button again The MONTH will appear and blink to be adjusted the DATE HOUR and MINUTE will follow as you press and release the MEMORY button C Press the
10. tly below your armpit 3 P a 57 Relax your entire body especially I the area between your elbow and fingers Pumping Measuring Note It is important to remain still and quiet 4 during measurement Any 473 i fe significant movement may 7 n affect measurement results 19 88 Results B If the cuff is not at the same level as your heart or if you can not keep your arm completely still throughout the reading use a soft object such as a folded towel to support your arm D Once the measurements have been displayed press the START STOP button to turn off the unit or it will automatically shut off after 150 seconds C Turn your palm upwards D Sit upright in a chair and take 5 6 deep breaths Note Avoid leaning back or crossing your legs while the measurement is being taken Fig C Start Stop Fig C Measurement Procedures Applying the Cuff To start the measurement To apply the cuff Note In order to get your correct measurement result and to avoid A Plug the end of the tubing on the cuff into the connector erroneous measurements you should be seated quietly Your arm at the base of the monitor hand and fingers should be still during measurement procedure B Unwrap the arm cuff leaving the Index end of the cuff A Press the START STOP button The display will initially through the D ring of the cuff