Home
icountPD
Contents
1. K oa 2 9 3 1 33 3 5 om 3 9 4 1 4 3 4 5 4 7 gt 4 8 Ea 1 5 1 6 alee 1 8 1 9 2 0 2 1 2 2 23 2 4 gt 2 45 Table relating NAS codes to Voltage output K lt 0 4 0 6 0 9 2 125 1 8 2 1 2 4 OL 32 0 Go Go 3 9 42 45 gt 4 6 lt 02 N S 0 3 05 0 7 0 9 vai ice TS dey 1 9 2 1 23 25 2 1 gt 2 8 Parker Hannifin Hydraulic Filter Division Europe 439 FDHB500UK icountPD icountPD Online Particle Detector Digital display parameters ISO 4406 NAS 1638 Start up 1 Once the icountPD has been connected to a regulated power supply the product logo is displayed for approximately five seconds as the icountPD performs a self system diagnostic check 2 The icountPD then automatically starts monitoring using factory default test parameters c MTD calibrated Channel sizes Limits Measured ISO codes RH Moisture sensor reading Automatic light sensor Notes ISO 17 16 14 and MS 43 RH ff fitted Digital display indication The digital display will show the actual measured codes the channel u size and the user definable limits Note that the channel size and limits are displayed alternately The Moisture Sensor reading Y oRH will also be shown if the Moisture Sensor option is fitted The order of trigger for both the codes and Moisture Sensor option is e Solid digit s code s that are at or below the set point limit e Flashing digit s code s
2. compact design requires no setting up or further user intervention as long as the system Working pressure range 10 to 300 bar conditions remain within the recommended Differential pressure range 10 to 300 bar pressure and viscosity ranges as below Working viscosity range 10 to 150 Cst icountOS Oil Sampler IOS e New and under development in the detection of contaminates distribution in various Aviation fuels e Portable monitoring tool providing fluid qualification to ISO 4406 1999 standards e Supplements the icount LCM20 and ACM20 product portfolio e Quick simple to use monitoring tool for sampling fluids from containers fuel bunkers and holding tanks e Field solution to Laboratory methods for the detection of solid contamination and free water inference Parker Hannifin Hydraulic Filter Division Europe 444 FDHBS00UK icountPD icountPD Online Particle Detector Hydraulic Connection Diagram Dimensions icountPD High Pressure Line Side Low Pressure Return Side o TF G1 8 ports either side of mounting block 90 0 4 holes 6 60 Thro 38 0 Ctrs Flow Control Actuator Specification P N 8840074 Operation Mounting Type Mounting position Weight Fluid Temperature Ambient storage temperature Viscosity range Differential pressure range Maximum pressure Flow direction Port thread detail Internal Seals Manual flow rate adjustable via control
3. protocol for the serial communication link is to be used with Microsoft Windows HyperTerminal The settings are as follows Baud rate 9600 Data bits 8 Parity None Stop bits Flowcontrol None The commands used with this product are made up of Read Set and Start Stoo commands e Set commands allow the value or values of parameters to be set e Read commands allow the value or values or parameters to be read e Start Stop allows the user to start and stop tests icoynt Alarm Limits Particle Limits Moisture Limit Class Code Moisture oRH Example SDF dd mm yy sets the date format RDF reads the product date format All commands are sent in ASCII characters and the protocol accepts both upper and lower case characters as the examples below SDF SdF Note A full list of commands are detailed in the user manual Parker Hannifin Hydraulic Filter Division Europe FDHBS00UK icountPD icountPD Online Particle Detector Ordering Information Standard Products Table Mineral MTD LED YES RS232 4 20MA NO M12 8 pin plug connector Mineral MTD LED VES RS232 4 20mA YES M12 8 pin plug connector Mineral MTD LED YEG RS232 0 5V NO M12 8 pin plug connector Mineral MTD LED YES RS232 0 5V YES M12 8 pin plug connector Mineral MTD Digital YES RS232 4 20MA NO M12 8 pin plug connector Mineral MTD Digital YEG RS232 4 20MA YES M12 8 pin plug connec
4. time to function to their best capability under load conditions through pistons servo valves control e Maintenance rams and gear pumps o Test Rigs o Flushing Stands e Industrial Equipment To increase efficiency of your equipment by o Production Plants continuously monitoring the cleanliness level of the o Fluid Transfers hydraulic fluid o Pulp amp Paper o Refineries e Fuel Contamination Detection To monitor the cleanliness of the equipment o Fuel Storage Tanks throughout the production line from the machine o Vehicle fuel tanks tool controlled hydraulics through to contamination of fluid transfer Ensuring the integrity of the fluid is maintained throughout the refining process o Uploading fuel into an aircraft 24 7 detection of particulate levels in most fuels including aviation fuel Jet A 1 fuel specification Parker Hannifin Hydraulic Filter Division Europe 438 FDHB500UK icountPD Variable mA output settings ISO V Output mA 0 1 2 3 45 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ISO CODE NAS V Output mA oO N o 4 5 6 7 8 9 10 11 12 13 NAS CODE Variable voltage output settings The following table can be used to equate the analogue output to an ISO or NAS Code Example ISO code 12 is equal to 10mA 4 0 4 5 5 0 5 5 6 0 6 5 7 0 1 5 8 0 8 5 9 0 a 10 0 10 5 11 0 11 5 12 0 125 13 0 13 5 14 0 14 5 15 0 15 5 16 0 16 5 17 0 eS 18 0 oO oli N
5. IoI o A 9 10 11 12 13 14 15 16 17 18 19 20 ERROR CO NIO AIAI OINI O CO NI oO G1 AI P O oO lie lie k lie NO peas pans e ow KK NDS k ol k O Ss N The following table can be used to equate the analogue output to an ISO or NAS Code oe NO Example ISO code 12 is equal to 10mA NO 4 20mA output settings ISO Setting mA current ISO Code 2 4 or ISO Code mA current 4 2 eg 10mA ISO 12 2 4 eg ISO 12 10mA 4 2 18 5 19 0 OVERRANGE les OVERRANGE 20 0 ERROR NAS Setting mA current NAS Code 5 Or NAS Code mA current 5 eg 15mMA NAS 10 5 eg NAS 10 15mA 5 The variable voltage output option has the capability of two different voltage ranges a O 5Vdc range as standard and a user selectable O 3Vdc range The Full list of commands on how to change the voltage Output are available from Parker The following tables can be used to relate the analogue ouptut to an ISO or NAS code For example in a O 5Vdc range ISO code 16 is equal to an output of 3 5Vdc In a O 3Vdc range ISO code 8 is equal to an output of 1 0Vdc Table relating ISO codes to Voltage output
6. countPD units contact Required Flow Range through the icountPD Parker Hannifin for advice 40 to 140 ml min Optimum Flow 6Oml min icountPD for use with aviation fuels Field Data Major International Airport First 3 measurements represent fuel gt 4u gt 6u gt 14u gt 21u gt 4u gt 6u gt 14u gt 21u from a previous cargo followed by a Test 1 81058 3 62126 1 17817 6 6066 2 Test5 1226 1 261 5 2 4 0 4 regular clean delivery thus demonstrating Test2 87834 5 74763 0 35454 1 18044 4 Test6 1085 7 210 9 Ta 0 1 the range of fuel cleanliness being Test 3 51383 4 32796 9 4424 8 1213 4 Test7 1037 9 198 7 1 3 0 1 experienced at this particular location Test4 1593 3 422 7 9 6 1 7 Ship Off loading AH ne Iih ticn 4 ti ae icountPD for use with aviation fuels Average Micron C Parker Hannifin Hydraulic Filter Division Europe 437 FDHB500UK icountPD Dimensions Installation Details mm inches 24 GTRS 110 4 37 182 72 60 ctrs lt 2 mounting locations to suit M5 socket head cap screw Screw pack supplied with icountPD icountPD flange thickness 10mm 0 4 Maximum Torque 5Nm Typical Applications e Mobile Equipment e Power Generation o Earth Moving Machinery o Wind Turbines o Harvesting o Gearboxes o Forestry o Lubrication Systems o Agriculture With continuous monitoring the optimum level is Monitoring of the hydraulics enabling the vehicles achieved in the least amount of
7. e detector see page 457 STI2144100 S171 2144 100 2 80 380 Mineral Yes ST10148100 ST1 0148 100 O 6 2 Aggressive 3 8 Yes STI1148100 STI 1148 100 1 20 100 Aggressive 3 4 Yes ST1I2148100 S171 2148 100 2 80 380 Aggressive 11 4 Yes T 5117210 STS 5117 210 1 20 100 Mineral 3 4 No TS 5217210 STS 5217 210 2 80 380 Mineral 11 4 No Parker Hannifin Hydraulic Filter Division Europe 444 FDHB500UK icountPD
8. ible construction Self diagnostic software Full PC PLC integration technology such as RS232 and 0 5Volt 4 20mA CAN J1939 Contact Parker for other options Set up and Data logging support software included Parker Hannifin Hydraulic Filter Division Europe FDHBS00UK icountPD icountPD Online Particle Detector Features amp Benefits Diagnostic Self Check Start up Time Online Flow Range via System 20 Inline Sensors Hydraulic Customer selectable 5 900 seconds systems only Measurement Period Size 0 6 to 25 l min Optimum Flow 15 l min 5 to 180 seconds Size 1 24 to 100 l min Optimum Flow 70 min Reporting interval through RS232 Size 2 170 to 380 l min Optimum Flow 250 l min O to 3600 seconds Required Differential Pressure across Inline Sensors Digital LED display update time 0 4 bar Minimum Every second Viscosity Range Limit Relay Output 1 500 cSt Changes occur 1 ISO code at set limit Hysteresis ON or customer Temperature set Hysteresis OFF Ambient storage temperature 20 C to 40 C 4 F to 104 F Particle RH Output Signal Environment operating temperature 5 C to 60 C 41 F to 140 F Continuous Fluid operating temperature 5 C to 80 C 41 F to 176 F Principle of operation Working pressure Laser diode optical detection of actual particulates 2 to 420 bar 80 6000 PSI International Codes Moisture sensor calibration Not offered with the fuel ver
9. icountPD Online Particle Detector For mineral oil aggressive fluids or fuels ATEX approved version available See page 476 Independent monitoring of system contamination trends The icountPD Particle Detector from Parker represents the most up to date technology in particle detection The design dynamics attention to detail and moulding compactness of the permanently mounted on line particle detector module combined with on board laser based leading edge technology brings to all industries a truly revolutionary particle detector as a remarkable cost effective market solution to fluid management and contamination control Contact Information Parker Hannifin Hydraulic Filter Division Europe European Product Information Centre Freephone 00800 27 27 5374 from AT BE CH CZ DE EE ES FI FR IE IT PT SE SK UK filtrationinfo parker com www parker com hfde icountPD for mineral oil applications Product Features e Independent monitoring of system contamination trends e Warning LED or digital display indicators for Low Medium and High contamination levels Visual indicators with power and alarm output warnings e Moisture RH indicator optional e Cost effective solution to prolong fluid life and reduce machine downtime e M2 8 pin or Deutsch Connector options 436 Continuous performance for prolonged analysis Fuel Hydraulic and phosphate Ester fluid compat
10. knob 4 off mounting holes to suit M6 screws not supplied Any 1 7kg 3 7Ib 5 C to 80 C 41 F to 176 F 20 C to 40 C 4 F to 104 F 20cSt to 500cSt If lower than 20cSt contact Parker 5 to 315 bar 315 bar IN to OUT flow control function 1 8 BSPP test points not supplied Fluoroelastomer This application shows uploading fuel into an aircraft with the icountPD in use to monitor as a go no go device Parker Hannifin Hydraulic Filter Division Europe 442 FDHB500UK icountPD Communication Options The icountPD may be configured using the icountPD Setup Utility For more direct control of the device using its communications protocol you may also use the Microsoft Windows HyperTerminal program but note that this program is not currently supplied with the Windows Vista operating system These two ways of communicating with icountPD are described in the following section icountPD Setup Utility software supplied C DeviceSetup File Options Help Darker z Detector ID Relay State C Comm Echo Product ID verbose Errors Part Number Relay Operation connect _ Serial Number STI Sensor Used Date Format Relay Hysteresis Reporting Standard Calibration Date Orientation Wesarenent penad Calibration due Date Brightness Reporting Interval Calibration Dust Power On Mode Auto start delay F voltage Range Not Connected Communication Protocol The Communication
11. sion ISO 7 22 NAS 0 12 5 RH over compensated temperature range of 10 C to 80 C Calibration 50 F to 176 F By recognised online methods confirmed by the relevant ISO proce Operating humidity range dures 5 RH to 100 RH MTD Via a certified primary ISO 11171 automatic particle detector Moisture sensor stability using ISO 11948 principles with particle distribution reporting to ISO 0 2 RH typical at 50 RH in one year 4406 1996 Certification ACFTD Conforming to ISO 4402 principles with particle distribution IP66 rated Refer to the EC Declaration of Conformity reporting to ISO 4406 1996 EMC RFI EN61000 6 2 2001 Recalibration EN61000 6 3 2001 Contact Parker Hannifin Materials Performance User friendly Abs construction 1 ISO Code Dependant on stability of flow Stainless Steel hydraulic block Reproducibility Repeatability Dimensions Better than 1 ISO Code 182mm x 155mm x 86mm 7 2 x 6 1 x 3 4 Power Requirement Weight Regulated 9 to 40Vdc 1 3kg 2 9lb Current Rating Seals Typically 120mA Mineral Fluorocarbon Aggressive EPDM Fuel Fluorocarbon Hydraulic Connection Computer Compability Mineral M16x2 test Points Parker recommends the use of a 9 way D type connector This can be Aggressive 5 8 BSF test Points connected to a USB port using a USB serial adaptor Note that these Fuel No test Points 1 8 BSP Female Ports Plugged connectors adaptors are NOT supplied with i
12. that are above the set point limit The display for IS04406 and NAS1638 are identical Error detection In the unlikely event of a error occurring the digital display on the icountPD will simply display the actual error code only i e ERROR 13 A full list of error codes are detailed in the icountPD User Manual Moisture sensor output settings The Moisture Sensor is an option that can be included when ordering the icountPD The Moisture Sensor reports on the saturation levels of the fluid passing through the icountPD sensing cell The output is a linear scale reporting within the range of 5 saturation to 100 saturation Table relating Saturation levels in the sensing cell to icountPD outputs Parker Hannifin Hydraulic Filter Division Europe 440 FDHBS00UK icountPD Flow control ACC6NN019 A pressure compensated flow control device Parker Hannifin part number ACCENNO19 has been develop to give the icount PD greater flexibility The flow control device enables testing where flow ranges are out side the icountPD specification i e 40 140 ml min or where pipe diameters do not allow the icountPD to be installed The flow control device fits onto the downstream PIN ACCONNO19 outlet side of the icountPD A O6L EO 24 deg cone and hydraulic adaptor is supplied which enables connection directly to the icountPD Alternatively the flow control device can be fitted further down stream The
13. tor Mineral MTD Digital YES RO2227 0 5V NO M12 8 pin plug connector Mineral MTD Digital YES RS232 0 5V YES M12 8 pin plug connector Product Configurator Deutsch 12 pin DT Series connector Mi12 8 pin plug connector Phosphate ester RS232 CAN bus J1939 Aviation fuel 4 channel oo Note Aviation Fuel option can also be used for Diesel fluids Note RS485 option communication up to 5000 Meters Contact Parker Note Wireless communication GPRS LAN WiFi Sat Contact Parker Accessories ACC6NE003 ACC6NNO02 1 metre hose length ACC6NNO03 ACC6NNO04 2 metre hose length ACC6NNO05 ACC6NNO06 5 metre hose length ACC6NNO07 ACC6NNO08 1 4 BSP fitting ACC6NNO09 ACC6NNO10 1 2 BSP fitting ACC6NNO11 ACC6NNO12 1 8 BNPT fitting SPS2021 SPS2061 Single point sampler S840074 Contact Parker Flow control device ACC6NNO19 Contact Parker Flow control valve ACC6NNO13 12 volt regulated power supply ACC6NNO14 Contact Parker 2x5 metre M12 8 pin cable kit ACC6NNO16 Deutsch Connector Kit ACC6NNO17 RS232 To USB cable kit ACC6NNO18 M12 8 pin to RS232 engineers tool M12 Cable kit consists of two 5 metre cables to enable all output options Communications cable and Relay Power Supply cable Note that the aggressive fluid hoses are provided as a single hose not in pairs Note For details on the icountPD Z2 ATEX approved particl