Home
Table of Content - RIO FLEXON TECHNOLOGY
Contents
1. 2 How to set the temperature alarm Before using the body temperature monitor function the operator may need to set both high and low temperature alarm figures according to the patient s general armpit temperature status When the temperature is out of the setting range the Receiver will start a series of Beeps alerting the caregiver to take appropriate actions The alarm setting procedures must be done when the armband is on Follow the steps below Step1 High temperature setting Press the Temperature setting key for 2 seconds the Receiver will beep twice to get into the temperature alarm setting mode The LCD screen flashes HI and the original figures will be displayed Step2 Press Temperature Setting Key to adjust the alarm temperature setting The temperature standard is 0 5 C a time such as 38 5 C to 39 C then to 39 5 C and so on then press Temperature setting key to complete the setting Step3 Low temperature setting low temperature setting starts automatically after finishing high temperature setting Please press Temperature Setting Key when LO is flashing and then adjust the low temperature setting The temperature standard is 0 5 C a time such as 34 C to 34 5 C then 35 C then 35 5 C and so on and then press Temperature setting key to complete the setting Remark The range of setting The default figures of the temperature alarm setting are Hi 38 C 104 F and Lo
2. Table of Content Table of Content 01 BTM DID Wireless Body Temperature Monitor User Manual 02 Introduction of BTM D1D Wireless Body Temperature Monitor 03 Operating Instructions 06 The Instructions of Indicators 11 Importance Precautions 13 Q amp A 14 Technical Specifications 16 BTM DID Wireless Body Temperature Monitor User Manual BTM D1D includes ReceiverX 1 Armband X 1 AAA battery X 2 3 Volt lithium cell battery CR2032 X 1 Arm belt X 1 Assisted arm belt X 1 Quick Guide Card X 1 Manual X 1 Warranty CardX 1 General Body Temperature Reference Ear Temperature 35 8 C 38 0 C ArmpitTemperature 34 7 C 37 3 C Oral Temperature 35 5 C 37 5 C Anus Temperature 36 6 C 38 0 C Introduction of BIM D1D Wireless Body Temperature Monitor 1 The instruction of the keys and functions N LCD Screen Beeper LO Setting Key HI Setting Key amp CIF Switch Temperature Setting Power Key Power Indicator S AAA batteres X 2 t Power key To turn on off the Receiver Temperature setting key To set up the Hi Lo temperature alarm Hi setting key To increase the Hi temperature alarm setting and to switch the C F Lo setting key To decrease the Lo temperature alarm setting Power indicator To indicate
3. is permitted Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user s authority to operate the device
4. keep noticing the caregiver to take appropriate action via the constant beeps if the patient s temperature is out of the temperature alarm setting Press any key on the Receiver to stop the beep alarm Remark Please keep checking the patient s temperature when alerting even some action to the patient had been done For not triggering the alarm every 10 minutes the caregiver can set the Hi Lo temperature alarm a little bit higher lower and then result the setting after the patient is getting better In case that the temperature when power on lowers the low temperature alarm setting then starts the alarm system this product will trigger the low temperature alarm system after normal temperature higher than the low temperature setting by 0 5 C It may cause low temperature alarm when the armband becomes loose Please check immediately the patient and adjust appropriately the arm belt The Instructions of Indicators 1 Armband Power Indicator Status Flashing Power On Every 4 seconds Power Off One blink then power off Low Volt Every 4 seconds when power on L 0 E No Signal Every 10 seconds when power on 2 Battery Power Supply Alarm The Low Battery Power Supply Status Full power supply Alarm of Receiver LCD Screen Battery Display Full battery on Receiver Battery Indicator No siren Low power supply Flashing on Receiver Battery Indicator
5. the status of power 2 The LCD screen of the Receiver illustration Armpit Temperature Mode e B Temperature Indicator r Hatata E CIF High Low Temperature Hi i58 8 E Alarm 404 St Wireless Transimdission Lv om Armband Battery Receiver Battery Indicator 3 The armband Back side Front side Power Indicator Power Key Battery Installation 1 Turn the counter 2 Insert the cell battery 3 Turn the clockwise to clockwise by using a close the battery cover coin or a screw driver to open the battery cover Note 1 This product is made by FDA Grade Silicone Clean the surface of armband with wet tissue Do not immerse the armband into water 2 Recommend to use CR2032 battery manufactured within 2 month If use poor quality or years old CR2032 battery it may easy to become powerless when power on which means the battery can not supply power normally How to assemble the armband to attach 0 How to wear the armband 1 Wear the armband on the left arm 2 Adjust the belt at the proper tightness 3 Move the temperature sensor under the armpit 4 Wear the assisted arm belt for fixing the sensor under the armpit Operating Instructions 1 How to use the armpit temperature function POWER ON Step 1 Wear the armband on the left arm and adjust the belt at the proper tightness Move the temperature se
6. 34 C 96 F The high temperature alarm range from 36 C to 40 C 96 F 104 F The low temperature alarm range from 32 C 35 5 C 89 F 96 F Faulty prevention mechanism If the above steps setting are not completed the Receiver will return to the temperature monitoring mode without changing any setting within 10 seconds Priority alarm processing The product is designed to process the alarm situation prior to the High Low temperature alarm setting mode or any other operations Without saving any setting if not pressing Temperature setting key the user is better off to operate the temperature alarm setting with the full power supply Please re set the Hi Lo temperature alarm figures after replacing the batteries The Receiver will take the default as the temperature alarm setting after battery replacement 3 Check the Hi Lo temperature alarm setting The Hi Lo setting 4 The Abnormal temperature alarm Alarm The Hi Lo temperature alarm setting on the LCD screen will be flashing on the Hi or Lo if the reading of the patient is out of the temperature alarm setting range That is the Hi and its figures are flashing The Receiver will beep every 2 seconds to inform the caregiver to take appropriate action Anti sleepyhead mechanism The Receiver will check every 10 minutes the temperature of the patient if it is still in the temperature alarm setting The Receiver will
7. And then press the power key for 2secs until red light is on to power off Now re start the Armband Press the power key for 2 seconds until green light is flashing 2 Replace the battery and start the device again Technical Specifications Receiver Armband One 3 Volt lithium cell battery CR2032 Up to 72 96 hours of constant operation If under airwave interference environment the battery life will be shortened Dimensions mm 130H X 50W X 32D 136H X 85W X 9 5D wes Operational surrounding 15 40 C temperature range Two AAA batteries Power supply Up to 80 100 hours of constant operation Temperature transmission Berii scond frequency y Valid temperature alarm ranges HI 36 40 C 96 104 F LO 32 35 5 C 89 96 F Transmission frequency The technique of the Radio FSK modulation Valid transmission distance 20 meters The precision of the Armpit 0 1 C temperature mE This product is certified by CE 0434 amp FCC EN60601 1 safety regulation for medical device EN60601 1 1 EN60601 2 compatibility regulation for medical device EN12470 4 EN12470 5 ISO 13485 2003 ISO 9001 2000 ISO 10993 1 2003 NOTE The changes or modifications are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment IMPORTANT NOTE To comply with the FCC RF exposure compliance requirements no change to theantenna or the device
8. Beeps twice every 10 seconds The Low Battery Alarm of Armband Power Supply Status LCD Screen Battery Display Alarm Siren Full power supply Low power supply Full battery on Armband Battery Indicator Flashing on Armband No siren Beeps twice every Battery Indicator 10 seconds 3 Poor Signal Warning The LCD shows C when it is failed to receive the signal from the Armband after turning on the Receiver it will beep twice every 10 seconds 11 Please turn on again the Receiver and the Armband to re set signal transmission Beep Beep Beep Beep fy 4 Solution for Poor Signal Within 3 minutes if disconnection occurred please remove the Receiver close to the armband while waiting for the screen in monitoring mode Otherwise the armband will automatically switch off after 3mins If the problem can not be solved from the above suggestion please restart both Armband and Receiver again 5 Error Solution LCD Screen Meaning Solution Ero Connection Abnormal System breakdown needed repair 9v a o y e Ko Importance Precautions Please follow the manual to operate this product carefully This product is designed to put the armband on the left arm This product is designed to function properly under the conditions of the surrounding temperature between 15 C to 40 C and the re
9. lative humidity of 95 or lower Please do not use this product when temperature and humidity is out of the ranges mentioned above The transmission distance of this product is approximately 20 meters without any interference The armband has passed the Biocompatibility Tests however if found allergic to the armband please stop using it Please do not use this product in the hospital in case the signal transmission would interfere with some electronic medical equipment The main function of this product is to alert the caregiver that the patient is out of the abnormal temperature range The measurement result however could sometimes be influenced by the surrounding temperature The measurement result is ONLY for reference Please seek qualified physician s help if necessary Please pay much attention on children with using this product Please also keep it out of reach of children and place it on a higher position Please do not use any rechargeable battery or mix of new and used batteries Please take out the batteries if the Receiver and the Armband will not be operated for a longer time 10 Please use the products after it has been placed under the normal room temperature for 30 minutes 11 Do not use this product directly after exercising bathing having meals and taking a walk etc Wait 30 minutes before using after all physical activity 12 The patient s armpit should be cleaned and dry before u
10. nsor under the armpit Step 2 Press the Power key on the armband for 2 seconds until the green light flash and it will flash every 4 seconds to indicate the device is working Step 3 Press the Power key on the Receiver for 2 seconds until it beeps and the LCD screen display the armpit temperature which means the wireless transmission is connected Step 4 Read the temperature on the LCD screen to check the change of the patient s temperature It takes 3 5 minutes to have stable temperature monitoring of armpit The temperature sensor will update armpit temperature every 12 seconds to be displayed on LCD screen POWER OFF Step 1 To turn the Receiver off press and hold the Power key for 2 seconds until it beep to turn off the LCD screen of the Receiver Step 2 Remove the armband from the patient s arm and press Power key on the armband until the red light flashes which means it is turned off Remark 1 When power on the green light only flashes once but not flashes every 4 seconds and disconnected please change the new battery 2 If outside of signal area and then result in disconnection please remove the receiver close to the armband within 3 min and then the signal will be connected 3 Any abnormal occurred when turn on the armband please check and change the battery 4 Recommend turning on both Receiver and Armband power within 20 seconds for connection otherwise it will automatically power off
11. sing this product 13 Please use the soft dry cloth to clean this product to avoid scratching Do not wash it with water or any other cleaner Q amp A Q The armpit temperature monitored is much higher or lower than normal A Please check the possible situation as follows 1 The patient may have a fever or the temperature may be too low 2 The Temperature Sensor does not reach the armpit or the armband is not tight enough 3 Low power supply please change batteries 4 Make sure you are not using this product directly after exercising bathing etc please put the product for 30 minutes at room temperature and then wipe it up 5 Possible interference please turn the product power on again 6 Out of order contact customer service immediately Q If allergy is evident after using this product A Please stop using it Q Failure to use the armband A 1 Please read carefully the manual again 2 Contact the seller Q Cannot turn on the Receiver 1 Please read carefully the manual again 2 Check the battery well to make sure batteries are in it or please change new batteries 3 Batteries may be not installed correctly 4 This product may be out of order please call to customer center Q The armband power indicator flashing with green and red light s the power key of armband the red light will light on and then press the power key again the green light will turn on
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung/Owners manual Notice de montage, d`utilisation et d`entretien Operating Manual MONARCH ® 1730® PRINTER OPERATING INSTRUCTIONS Contacto de ventana RF Téléchargez - Canadian Tire bulletin municipal d`informations n° 74 The Bunny Lover`s Complete Guide To House Rabbits 1 - Agilent Technologies Copyright © All rights reserved.
Failed to retrieve file