M4348 Data logger NEW Language: English

image

Contents

1. 384 KompaktM 1 Display 2 Lamp YELLOW serial data transfer is acting 3 Lamp GREEN device is in automatic switching 4 Lamp RED disturbance 5 Key UP 6 Key ENTER 7 Key DOWN 8 Keyswitch SETUP Operating Mode AUTO The key AUTO can only be removed if it is positioned on AUTO 9 Contrast adjustment display BDL 4348V1E DOC page 2 of 10 Arndt amp Vol GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 V01 Back view X312 4 Analog input for 8 channels 5V or 10V X312 5 Single start inputs X312 6 Common start input X312 9 Analog input channel 1 X412 Test jack X401 power supply plug X402 RS 232 interface connection to the selection unit S1 Mains switch F1 Mains fuse 12V Check lamp 12V supply 12V Check lamp 12V supply 5V Check lamp 5V supply BDL 4348V1E DOC page 3 of 10 Arndt amp Vol GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 V01 2 Power supply Connect plug X401 of A amp V 4384 via the power cable Euro norm with 230V 50 60 hertz and turn on the mains switch S1 on the back 3 Setup Key operated switch at position SETUP In the operatin
2. Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 V01 3 3 Deleting individual channels The operating mode DELETE SINGLE is always possible if the previous value recording was made via the single start inputs In this case every programmed measuring channel was stored only if its corresponding start input was active All stored measured values of the chosen channel are deleted After deletion a change of the channel number is only possible at the analog input by the corresponding reservation if all channels were deleted separately The yellow lamp lights up briefly the number of measured values is set to zero Display DELETE SINGLE 1234 1 1 channel number depending on display channel chosen before number of measured values of the current channel By activating the scrolling key UP 5 or DOWN 7 the desired channel can be chosen The deleting process is started if both scrolling keys UP 5 DOWN 7 are pressed simultaneously The yellow lamp lights up briefly the number of measured values is set to zero At the time of the deleting process the channel number for the next measured value to be stored is not known yet Only during the storing of the first measured value the channel number is determined by chaotic measuring yes no 3 4 Diagnosis By pressing the pushbutton ENTER it is switched from De
3. and start mode With the first measuring after the complete deletion of the memory the channel number is adopted from the coding of the analogous connection cable At the same time the first measured value adoption determines if all programmed channels are stored simultaneously via the common start input or if each programmed channel is stored separately via the individual start inputs chaotic measuring CAUTION The data logger may only be connected to a measuring unit if the earlier stored measured values were deleted Exception Reading and analyzing the values and go on working at the same measuring unit The recording mode can only change after deletion 4 2 Measuring via the common start input X312 6 The analog signal connection is to be chosen via the entry socket reservation with 5V or 10V Store the value by pressing the pushbutton ENTER or through the common start input Before after the storing of the values the adjusted delay time passes During the cycle time the green lamp is off and the output signal BUSY see 4 4 measuring course is set In every measuring cycle the measured values for all programmed measuring channels are stored i e the number of measured values is identical for all programmed measuring channels 4 3 Measuring via the single start input X312 5 For every programmed measuring channel a start signal has to be given by an external switch Before after the storing of the values the adjusted delay t
4. Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 v01 M4348 V01 8 channel data logger Contents Page 1 Display and control elements 2 3 2 Power supply 4 3 Setup 3 1 Reading 3 2 Deleting all channels 4 3 3 Deleting individual channels 5 3 4 Diagnosis 5 3 4 1 Choice of language version 3 5 Delay time 3 6 Displaying measured value 6 4 Measuring operation 6 4 1 Adoption of channel numbers and start mode 4 2 Measuring via the common start input X312 6 4 3 Measuring via the single start input X312 5 7 4 4 Measuring course 7 4 5 Error reports 8 5 Connection schematics 9 Security comments according to VDE 0411 10 The data logger M4348 V01 replaces the predecessor type AYE 4348 It is used principally in mobile measuring systems in quality assurance The data logger is able to store analogous voltages as digitized measuring values Since the memory stores the taken values even if it is disconnected and transported and the analysis of the stored measured values can be carried out in any data processing system with serial interface it is a low cost solution for automatizing quality control BDL 4348V1E DOC page 1 of 10 Arndt amp VoR GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 V01 1 Display and control elements Front view esseinheit
5. VoR amp GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de User s Manual Arndt amp Vols GmbH M4348 V01 Mefgtechni 5 Connection schematics Elektroni ala LISREHN INO TO FEHI HES 1 Loog r wneg ap anju pA Son DUDU IELLS W927 MEY 094 GET Talp 00 hH BL GuniGis quences Jayaadspamy ayy ap SSO PUN IPWUE miny duu PAEL ot 0 4 opg HO 200 S DU Sa1ELUSDUEL US up aus doe L HA g pneg 0096 ala PHUyYIS cEg SH neaeansd g JEUEH Up 2 UE hE g ue pE Gbueu e t Eug HES E Buey He g BUB He BUEN HE augues azu E E E EI E E E 6 H H H H F E H L CIFA aze aZe ALs cO xew Jajddoy Dugbsrg AZ LA ydg AA NAAEENS SZEX H HES SWS Fd Pugbu gsJ FAL 2 EC LA H EC Eer It g EC LI G EC A t ah E CC A z IZ L uayarug auey LEZUEISUEN ap DUpueuug DO Lu IZ ayang SHUEBUERO RU ISfE8NS KCL Aud b g BUEY BUEH 9 BUEY 5 BUEM t BUEM E IL g BUEM Lux age 9 of 10 BDL 4348V1E DOC Arndt A VoR GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 V01 Security comments according to VDE 0411 General technical ti
6. d can be changed by the scrolling keys UP 5 or DOWN 7 in the field 999 3 6 Displaying measured value By pressing the pushbutton ENTER it is switched from Delay time to Display measured values The actual measured value can be displayed of every channel in the field 999 Display meas val chan 123 1 1 channel number depending on the chosen display channel measured value of the current channel With the scrolling keys UP 5 or DOWN 7 all 8 channels can be dialed The measured value changes correspondingly By pressing the pushbutton ENTER the display Measured values is switched to READING 4 Measuring operation Key operated switch to position AUTO If the green lamp lights up the device is ready If the Start X312 6 or Start input X312 5 becomes active now the corresponding measured value is stored Display meas val chan 1234 1 1 channel number depending on the chosen display channel number of stored measured values of the current channel With the scrolling keys UP 5 or DOWN 7 all channels can be dialed With this the number of measured values of the corresponding channels is shown on the display BDL 4348V1E DOC page 6 of 10 Arndt A VoR amp GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 v01 4 1 Adoption of channel numbers
7. g mode SETUP the output signal BUSY see 4 4 measuring course is set 3 1 Reading After the key operated switch has been brought to the position setup the operating mode reading appears on the display The device is waiting for a command from the reading device As soon as a connection exists the yellow lamp lights up In this operating mode all stored measured values can be transmitted to the reading device Display READ 1234 1 1 channel number depending on the display channel chosen before number of measured values of the current channel 3 2 Deleting all channels By pressing the pushbutton ENTER it is switched from READING to DELETING The operating mode DELETE ALL is always possible if the previous value recording was made via the common start input In this case all programmed measuring channels were stored synchronously All stored measured values are deleted The measured values of all channels are lost After deleting a change of the channel number is possible at the analog input by the corresponding reservation Display DELETE ALL 1234 1 1 channel number depending on display channel chosen before number of measured values of the current channel The deleting process is started if both scrolling keys UP 5 DOWN 7 are pressed simultaneously The yellow lamp lights up briefly the number of measured values is set to zero BDL 4348V1E DOC age 4 of 1 Arndt A VoR amp GmbH Eichhofstr 7 D 21255 Tostedt
8. ime passes During the cycle time the green lamp turns off and the output signal BUSY see 4 4 measuring course is set In every measuring cycle measured values are only stored from measuring channels whose input signals are active i e the number of measured values per measuring channel can be different 4 4 Measuring course After the start signal is active green lamp turns off the initial signal BUSY is turned on for the programmed waiting time BUSY can be used for a handshake with maschines When the measured value memory is full BUSY is set permanently Memory capacity is dependent on the number of channels as follows Number of channels max number of measured values per channel 9984 9984 6912 6656 3328 3328 3328 3072 ONOOARWDN A BDL 4348V1E DOC page 7 of 10 Arndt A VoR amp GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 V01 4 5 Error reports In automatic operation the following errors are displayed Display No channel FAIL Significance Programmed channel number does not match that of the analogous cable Remedy Delete measured value memory Display FULL MEMORY Significance Capacity limit atteinted by one or several measuring channels Remedy Read measured values and then delete the measured value memory BDL 4348V1E DOC page 8 of 10 Arndt A
9. leting to Diagnosis In this operating mode individual functions can be tested Display Start S A Chan 000000000 3 4 4 currently programmed channel number 3 channel number of the connected analogous recording cable 0 common start input passive 1 common start input active 87654321 order of the single start inputs of each channel 0 start input passive 1 start input active 3 4 1 Choice of language version The display mode Diagnosis is chosen Press the arrow keys UP and DOWN simultaneously The programme version appears briefly Then the dialed language appears DEUTSCH FRANCAIS ESPANOL or ENGLISH By pressing the arrow key UP or DOWN choose a language Afterwards press arrow key RIGHT Now the display mode Diagnosis appears again and the chosen language is stored permanently BDL 4348V1E DOC page 5 of 10 Arndt A VoR amp GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de Arndt amp Voli GmbH User s Manual Elektronik Me technik M4348 v01 3 5 Delay time By pressing the pushbutton ENTER it is switched from Diagnosis to Delay time The delay period which occurs before after measuring can be programmed here Display msec delay 123 1 1 chosen channel number of no significance here 123 delay of 0 123 sec BEFORE measured value adoption 123 delay of 0 123 sec AFTER measured value adoption The delay perio
10. me for warming up 20 minutes temperature 0 40 Grd C atmospheric humidity on to 75 rel frequency 50 60 Hz power supply voltage 230V 10 security according to VDE 0411 protection class 1 This unit is built and checked under DIN 57411 part 1 VDE 0411 part 1 and left the factory in a safe and perfect condition To preserve this condition and to guarantee a safe working the user has to follow the comments and warnings which are given in this instructions Before turning on the power you have to make sure that the voltage of operation and the mains voltage correspond The mains plug may only be inserted into a socket with ground contact The safety effect may not be abolished by an extension lead without ground connection The opening of covers or removing of components except if it is possible to do by hand might uncover parts or connections under dangerous voltage Racks may only be used inside a cover If an adjustment a maintenance or a repair at the opened unit under voltage is unavoidable it may be done only by a qualified employee who is well aqainted with the dangers involved ATTENTION After the end of those works the unit has to be checked according to VDE 0411 part 1 You have to make sure that only fuses of the given type and values are taken for replacement The use of mended fuses or short circuiting them is inadmissible If it is presumed that a safe work is not possible you have to take this unit out
11. of work A safe work may not be possible if there are visible damages at the unit the unit doesn t work after longer storage under unfavourable circumstances after heavy stress of transport BDL 4348V1E DOC page 10 of 10 Arndt A VoR GmbH Eichhofstr 7 D 21255 Tostedt Telefon 49 0 4182 289 760 Fax 289 761 email arndtundvoss t online de http www arndtundvoss de