Home

5000XL Web Server - ABLE Instruments & Controls

image

Contents

1. A 3i_E Instruments amp Controls Installation amp Maintenance Instructions Computrac Max 5000XL Web Server Operation Manual Arizona Instrument LLC Reading Office Aberdeen Office Cutbush Park Danehill Lower Earley Unit 6 Airside Business Park Kirkhill Industrial Estate Reading Berkshire RG6 4UT UK Dyce Aberdeen AB21 OGT UK Tel 44 0 118 9311188 Tel 44 0 1224 725999 Email info able co uk Email ab able co uk Internet www able co uk e procurement www 247able com Registered in England No 01851002 VAT No GB 417 2481 61 FPAL COM MAX 5000XL Web Server User s Manual WEB SERVER for the COMPUTRAC MAX 5000XL User s Manual PROPRIETARY RIGHTS NOTICE This manual contains valuable information and material developea by Arizona Instrument LLC for use with the Web Server for the Computrac MAX 5000XL Analyzer No part of this manual can be reproduced or transmitted in any form or by any means electronic mechanical or otherwise This includes photocopying and recording or in connection with any information storage or retrieval system without the express written permission of Arizona Instrument LLC ALL RIGHTS RESERVED Copyright 2006 2012 Arizona Instrument LLC Internet Explorer and Excel are registered trademarks of Microsoft Corporation in the United States and other countries Page 2 of 20 MAX 5000XL Web Server User s Manual TABLE OF CONTENTS
2. Download Test amp Graph Data Click on Download Tests With Graphs button You will be asked to save or open a file named testgraphs csv Save it to your desktop e Once saved open the file testgraphs csv This should open up an Excel spreadsheet with all the selected test data Verify the test data information is the same between the instrument and the Excel spreadsheet by selecting the data Moisture through Rate Minute Be sure to capture all the data for the particular test result See the selection on the next page showing the beginning and end of the test data The screens displayed might be slightly different depending on the version of Excel being used Page 16 of 20 MAX 5000XL Web Server User s Manual Ej Microsoft Excel testgraphs csv Talki Ej Microsoft Excel testgraphs csv Me xe Bl File Edit View Insert Format Tools Data Window Help amp X BI Fie Edit wiew Insert Format Tools Data Window Help f X iagHaaa Tas amp xa amp o r i amp eBsBasuasasga asa9 r me Bsp u fata d 19 5 5 2 fa Y Reply with Changes fe Moisture LIFT 10096 LOW MOI0 0000 Moisture ASHING RO 0 Minute LINKED TCNo LINK RES Individual LINK USE FOLID SAMPLE I LABLETEST LOT NUMBER
3. amp 1921682140 CALIBRATION REPORT LCD VIEW MEMORY STARTS Factory TARTRATE TEST RESULTS Factory LACTOSE MONOHYDRATE Factory MILK MOISTURE Factory MILK ASH Factory DRIFT Memory Start 7 Memory Start 8 Memory Start 9 Memory Start 10 Memory Start 11 Memory Start 12 Memory Start 13 Memory Start 14 Memory Start 15 Memory Start 16 Memory Start 17 Memory Start 18 Memory Start 19 Memory Start 20 Compatibility View icon Select memory starts to download Use Shift key to select range Use CSV file extension when saving files Download Browse Upload Copyright 2005 Arizona Instrument LLC v To upload a previously downloaded set of memory starts eTo indicate where the uploaded memory starts should be stored select the desired memory start in the list shown in Internet Explorer The memory starts in the stored csv file will load in the position following the selected position on the list Use the Browse button on the memory start page of the Web Server to select the csv file to upload Use the Upload button to send the file to the instrument The message UPLOAD COMPLETE appears on the web page Page 14 of 20 MAX 5000XL Web Server User s Manual 4 4 TEST RESULTS Click on TEST RESULTS in the left sidebar hai MAX 5000XL AZ Preferred Customer CALIBRATION REPORT LCD VIEW MEMORY STARTS TEST RESULTS LACTOSE MONOHYDRATE LACTOSE
4. Page 18 of 20 MAX 5000XL Web Server User s Manual 9 WARRANTY Arizona Instrument LLC warrants the Computrac MAX 5000XL to be free from defects in materials or workmanship for two 2 years from the date of purchase for those units sold in the USA All other sales normally carry a one 1 year warranty AZI will repair or replace at its option products that AZI determines to be defective during the warranty period All defective parts replaced by AZI become the property of AZI Replacement parts are warranted for the remaining portion of the effective warranty period This warranty does not apply to expendable or maintenance items such as pans and pan supports The above warranty does not extend to any product which has been subjected to misuse abuse neglect accident improper application modifications or service performed by persons other than AZl s own service representatives power surges or spikes negligence in use maintenance storage transportation or handling or acts of God If a MAX product is defective in workmanship or materials the owner s sole remedy shall be repair or replacement of the defective part or parts as provided above Under no circumstances shall AZI be liable in any way to the owner or any user for any damage including but not limited to any loss of business or profits or any other direct indirect special incidental or consequential damages whether or not foreseeable and whether or not ba
5. 1 OVERVIEW amp COMPATIBILITY esee see erre eee eene 4 2 FEATURES sira a a a 5 2 1 Calp on REPOL isorine oti arinina TEE obice etd 5 Di L D W E E E J X 6 2 9 MOBIOEY o e aI E T TE E E ES 6 24 TRE E E E E E E 7 3 SET UP WEB SERVER on the INSTRUMENT 8 NAME and PASS WOBRIO kite eiudiccteteatecesiu totu be epist desit em rasta ia uiuere A 8 COB TINE TP PRS X YM 9 MAC RTS E 9 TATUS 9 4 SET UP WEB SERVER on the target PC 10 d h CALIBRA HON REPORT 2nietsditese dieti misisset ten qiie ioeeee bete iib bares en 11 bil P 12 2 3 MEMORI START eea E sect votes E A E redi eive mI 13 DOWNLOAD MEMORY STARTS eeeseseeeeeeeeeene nnne enne nnne nnn nns 13 UPLOAD MEMORY bod Ba dl eee eee ee ees eT one teers etiam iet uM uite 14 dA TETERE UCD renee E er ee ere ere mide ium ius 15 3 WTI f 19 An up to date electronic copy of this manual is available at http www azic com Page 3 of 20 MAX 5000XL Web Server User s Manual 1 OVERVIEW amp COMPATIBILITY Thank you for your purchase of the Web Server option for the MAX 5000XL Web Server is compatible with Microsoft Internet Explorer
6. 4 2 LCD VIEW Click on LCD VIEW in the left sidebar WV i MAX 5OOO0XL AZI Preferred Customer SN 500117 CALIBRATION REPORT 11 Jan 2007 16 31 33 LCD VIEW MEMORY STARTS TESTED WEIGHT TEST RESULTS RESULT 37 5154 Moisture TIME 1 33 TO TEST WEIGHT PRESS START MEMORY SELECTS PRESS MEMORY NEW PARAMETERS PRESS PARAMS 28 0 58119 z CONTRAST MEMORY MENU GRAPH PARAMS Copvright 2005 Arizona Instrument LLC The instrument can be monitored from this screen Verify the view on the computer screen is the same as what is showing on the instrument Change the screen on the instrument and observe the change on the computer screen The PC may take a few seconds to respond on the computer screen as the browser refreshes Page 12 of 20 MAX 5000XL Web Server User s Manual 4 3 MEMORY STARTS Click on MEMORY STARTS in the left sidebar bili MAX 5000XL AZI Preferred Customer SN 500117 CALIBRATION REPORT LCD VIEW Factory WEIGHT MEMORY STARTS Factory TARTRATE Factory LACTOSE MONOHYDRATE Factory MILK MOISTURE Factory MILK ASH Factory DRIFT Memory Start 7 Memory Start 8 Memory Start 9 Memory Start 10 TEST RESULTS hl t p il L J Select memory starts to download Use Shift key to select range Use CSV file extension when saving files Upload Copynght 2005 Arizona Instrument LLC This allows the memory starts to be viewed and stored on th
7. IE versions 6 7 8 and 9 both 32 bit and 64 bit versions of IE 9 With the Web Server option Internet Explorer is used to view a calibration report view the MAX 5000XL s LCD screen save load memory starts and save test results As detailed in this manual to access the instrument with Internet Explorer type the IP address of the instrument 192 168 2 254 for example into the Internet Explorer address field Memory starts can be retrieved from one instrument and saved to another Test data is saved in a comma delimited format which can be read by Microsoft Excel or a compatible spreadsheet program NOTE Test results data cannot be modified or deleted through the Web Server Data can only be deleted at the instrument Page 4 of 20 MAX 5000XL Web Server User s Manual 2 FEATURES 2 1 Calibration Report The calibration report is viewed by selecting CALIBRATION REPORT in the left sidebar This report is a combination of the balance and temperature calibration report Use the Download button to download the report as an HTML file y v MAX 5000XL AZI Preferred Customer SN 500117 CALIBRATION REPORT LCD VIEW MAX 5000XL CALIBRATION REPORT ee atp da COMPANY NAME AZI Preferred Customer TEST RESULTS INSTRUMENT 2 500117 FORCE BALANCE 1730 FACTORY CAL DUE 01 Jan 2008 BALANCE CALIBRATION LAST PASSED CAL 04 Sep 2007 TEMPERATURE CALIBRATION LAST CALIBRATION 24 Aug 2007 LAST VERIFICATION
8. PRODUCT ID E iDraw g AutoShapes amp 1 O 4 oo Bl m ar A E iDraw g AutoShapes w 1 O 4 2s 8l m w A E Ready Siim 1 4932 ZA Ready S m 15 6533 d ne P pma im i i 4 eAfter selecting the data click on Insert gt Chart EH File Edit view D Ez ld c Du fta mu cd x Worksheet C34 x A T Bj e o Sx Function Tools Data Window Help l9 4 e Hisp We Reply with Changes B Inserk Format Rows Columns co co coa ca ca CO C0 ca cO CO CO CO CO 7 7 m m m0 mL 0E 0E 0 BERR OWS KH OOO OOo ooo OeEOMOnNMNOROMNOR OOM OR ODS OR Om P 248 EST DATA 250 so SAMPLEILABLETEST 251 LOTNUMBER 252 1 pPRODUCTID M4 Fl grap Drawy Lg AutoShapes NO w CO B3 jJ ct ual A Ready uim d 5 5555 a l i adipe Page 17 of 20 MAX 5000XL Web Server User s Manual Chart Wizard Step 1 of 4 Chart Type _ x e Select line chart and click Standard Types Custom Types Next gt Chart type Chart sub Evpe e Continue clicking Next gt until Finished HE Bubble with markers displayed at each data alue Press and Hold to View Sample Cancel lt Back met Finish e The graph of the test results from the instrument can now be saved within the Excel spreadsheet for backup and future use
9. 196 168 2 254 MAC ADDRESS The MAC address is factory set and is unique to every Internet device It may be helpful to your IS department STATUS This displays the Ethernet status If everything is setup correctly then the status should turn to Initialized shortly after power up Otherwise an error will be reported To save any changes made to the Ethernet Setup options after making the desired changes press ESC and then follow the on screen instructions to ESC back to the Main Menu and then power the instrument off and back on Page 9 of 20 MAX 5000XL Web Server User s Manual 4 _ SET UP WEB SERVER ON THE TARGETPC Open an Internet Explorer web browser window from the PC Fr e Arizona Instrument Exclusive Manufacturer of Computrac Moisture Analyzers and Jerome Toxic Windows Internet Explorer oy WRG E htt azic com v File Edit View Favorites Tools Help 5 Convert v m Select yip Favorites e Arizona Instrument Exclusive Manufacturer of C Dv B de v Pagew Safetyv Tools v v ARIZONA INSTRUMENT LLC Home Industries Instruments Customer Service Contact Us COMPUTRAC Jz Lo MOISTURE SOLIDS ASH LOI Rapid Loss on Drying Relative Humidity Sensor a Green Karl Fischer Alternative GSA CONTRACT DISTRIBUTORS TRADESHOWS BROCHURES DOWNLOADS Internet Protected Mode Off Type the IP address written down in the previous step e g 192 168 2 254 into the add
10. 24 Aug 2007 CAL MODULE 1930042 CAL PROBE 254 MODULE CERT DATE 22 Mar 2007 CALIBRATION RESULTS TEMP 46 6 C 86 8 C 129 2 C 174 5 C 222 0 C 271 7 E P a hy We 3 2 39 429 1 C 483 6 C 538 3 C 565 8 C VERIFY RESULTS INSTRUMENT TCI DIFFERENCE 50 0 C 49 6 C 0 4 C Pass 100 2 C 100 3 C 0 1 C Pass ZNLI C 150 1 C 0 0 C Pass 200 0 C 199 9 C 0 1 C Pass 250 0 C 249 9 C 0 1 C Pass 300 0 C 299 8 C 0 2 C Pass Copyright 2005 Arizona Instrument LLC Page 5 of 20 MAX 5000XL Web Server User s Manual 2 2 LCD View To view the LCD screen on the MAX 5000XL select LCD VIEW in the left sidebar This allows real Aili MAX 5000XL AZI Preferred Customer SN 500117 CALIBRATION REPORT LCD VIEW MEMORY STARTS TEST RESULTS 11 Jan 7007 16 31 39 TESTED WEIGHT RESULT 37 5154 Moisture time remote monitoring of the TIME 1 33 instrument TO TEST WEIGHT PRESS START MEMORY SELECTS PRESS MEMORY 5 NEW PARAMETERS PRESS PARAMS 28 0 5811g i CONTRAST MEMORY MENU GRAPH PARAMS Copyright 2005 Arzona Instrument LLC 2 3 Memory Starts Memory starts can be viewed by selecting MEMORY STARTS in the left sidebar hai MAX SOOOXL AZI Preferred Customer SN 500117 CALIBRATION REPORT LCD VIEW Factory WEIGHT MEMORY STARTS Factory TARTRATE Factory LACTOSE MONOHYDRATE Factory MILK MOISTURE Factory MILK ASH Factory DRIFT Memory S
11. MONOHYDRA LACTOSE MONOHYDRA LACTOSE MONOHYDRA LACTOSE MONOHYDRATE TARTRATE TARTRATE TARTRATE TARTRATE WEIGHT WEIGHT 04 Sep 2007 4 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 3 38 8 2 3968 2 3947 3 3999 2 4108 15 7099 15 7198 15 6980 15 7059 15 7018 0 0427 37 9016 3 5114 37 5117 37 5120 37 5095 37 5156 37 4907 Select test results to dawnload Use Shift key to select range Use CSV file extension when saving files Download Tests Copyright 2005 Arizona Instrument LLC Download Test amp Graph Data This allows the user to retrieve data directly from the instrument SN 500117 NOTE Data cannot be deleted from the instrument through the Web Server Select one item from the displayed results table You can select a range of items by holding down the shift key Click on the Download Tests button You will be asked to save or open a file named testdata csv Save it to your desktop Once saved open the file testdata csv This should open up an Excel spreadsheet With all the selected test data Verify the test data information is the same between the instrument and the Excel spreadsheet The test results can now be saved in the My Documents 4 My Computer Recent Epson drivers hy Documents
12. Wr My Computer JTEMP DESK My Network Places _JExpense reports JriaxSk manual update JJSCIENTECH PHOTOS TEI disk docmentation update Af Company Phone List xls PC for backup purposes p hy Network File name ftestdata csv 7 Microsoft Excel worksheet Cancel E Places Save as type Page 15 of 20 MAX 5000XL Web Server User s Manual Return to the TEST RESULTS screen and select one item from the displayed results table You can select a range of items by holding down the shift key Ai max 5000XL CALIBRATION REPORT LCD VIEW MEMORY STARTS TEST RESULTS AZI Preferred Customer LACTOSE MONOHYDRATE LACTOSE MONOHYDRATE LACTOSE MONOHYDRATE LACTOSE MONOHYDRATE LACTOSE MONOHYDRATE TARTRATE TARTRATE TARTRATE TARTRATE TARTRATE DRIFT WEIGH WEIGH WEIGH WEIGH WEIGH WEIGH WEIGHT 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 4 Sep 2007 04 Sep 2007 04 Sep 2007 04 Sep 2007 O04 5ep 200 2 3878 2 39608 2 3847 2 3999 2 4108 15 7099 15 7198 15 6980 15 7059 15 7018 0 0427 37 5016 37 5114 37 5117 37 5120 37 5095 37 5156 37 4907 SN 200117 Select test results to download Use Shift key to select range Use CSV file extension when saving files Download Tests Co yright 2005 Anzona Instrument LLC
13. e PC The memory starts can also be uploaded into the instrument or into a different MAX 5000XL Verify the memory starts are the same between the instrument and the computer DOWNLOAD MEMORY STARTS Click on any memory start or select several memory starts by holding down the shift key Press on the Download button It will ask you to save or open the memstarts csv file Navigate to the desktop and click Save My Documents Y My Computer Open the memstarts csv file Bb dE and view the data This Z TEMP DESK Company Phone List xls should open up an Excel JB spreadsheet with all the My Computer memory starts data Verify PM the memory start information D hy Network File name memstarts csv gt the diis between the bod Save as type Microsoft Excel worksheet Cancel instrument and the Excel y spreadsheet It can now be saved on the PC for backup purposes Page 13 of 20 MAX 5000XL Web Server User s Manual UPLOAD MEMORY STARTS NOTE On Internet Explorer 9 the IE Compatibility View feature must be used to upload memory starts Click the Compatibility View icon located to the right of the address bar as indicated below The icon should turn from gray to blue Once the icon is blue perform the steps below to upload memory starts Go e http 192 168 2 140 m5k htm AZI Preferred Customer SN 500353 y v NV j Factory WEIGHT x x J oe P BCX
14. ight property of CompuServe Incorporated GlF sm is a Service Mark property of CompuServe Incorporated Copyright 2006 2012 Arizona Instrument LLC All Rights Reserved Arizona Instrument LLC Web Server for the Computrac MAX 5000XL Moisture Analyzer Manual Part Number 700 0115 Revision C February 2012 lf you have any questions regarding the operation of this instrument please call or e mail for assistance Arizona Instrument LLC 3375 N Delaware St Chandler AZ 85225 800 528 7411 602 470 1414 Fax 480 804 0656 http www azic com email azi azic com General intl azic com International support 2azic com Customer Support Page 20 of 20
15. instrument over the gue 7h intranet This window will be displayed from the Internet Explorer browser if there is a password entered in the ETHERNET SETUP screen above If the password is left blank this login screen will not appear User name Password calrpEview htm Remember my password When the login screen appears in Internet Explorer use the NAME and PASSWORD entered in the ETHERNET SETUP screen shown above to gain access to the instrument Page 8 of 20 MAX 5000XL Web Server User s Manual OBTAIN IP ADDRESS This can be set to Automatic Manual or Ethernet Off Automatic Sets everything automatically A DHCP server is required to obtain the IP address Because the IP address is not known until the DHCP server assigns it intranet users will have to be given the IP address whenever the instrument powers up which is undesirable Manual mode is typically used because the IP address is fixed Automatic mode is useful to see if the web server works and then the user should switch to manual mode Manual Requires the manual entry of IP address subnet mask and gateway Consult with your Information Services IS department for the correct settings WARNING DO NOT SET THE IP ADDRESS TO THE SERVER OR GATEWAY IP ADDRESS Doing so can cause the network to crash Ethernet Off Disables the Ethernet port Write down the IP address This will be needed to connect to the instrument through the PC e g
16. ress bar of the browser and press ENTER or click the Go button NOTE DO NOT ENTER ANY LEADING ZEROS This will bring you to the Home page CALIBRATION REPORT Note If multiple ORUM browsers attempt to TEST RESULTS connect to the same instrument at the same time unable to allocate packet errors will result Page 10 of 20 MAX 5000XL Web Server User s Manual 4 4 CALIBRATION REPORT Click on CALIBRATION REPORT in the left sidebar hui MAX SOOOXL AZI Preferred Customer SN 500117 CALIBRATIOM REPORT LCD VIEW MAX 5000XL CALIBRATION REPORT MEMORY bind COMPANY MAME AZI Preferred Customer TEST RESULTS INSTRUMENT 500117 FORCE BALANCE 1730 FACTORY CAL DUE 01 Jan 2008 BALANCE CALIBRATION LAST PASSED CAL 04 Sep 2007 TEMPERATURE CALIBRATION LAST CALIBRATION 24 Aug 2007 LAST VERIFICATION 24 Aug 2007 CAL MODULE 1930042 CAL PROBE 254 MODULE CERT DATE 22 Mar 2007 CALIBRATION RESULTS TEMP 46 6 C 86 8 C 129 2 C 174 5 C 222 09C ITLl C 323 1 C j75 3 C 429 19C 483 69C 238 39C 265 89C VERIFY RESULTS DIFFERENCE 0 4 C Pass 0 1 C Pass 0 0 C Pass 0 1 C Pass 0 1 C Pass 0 2 C Pass Copyright 2005 Arizona Instrument LLC The data on the report can be printed directly from the browser by using the browser s print function or the data can be downloaded and saved to the PC by using the Download button Page 11 of 20 MAX 5000XL Web Server User s Manual
17. sed on breach of warranty contract or negligence in connection with the sale of such products Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you No other warranty is expressed or implied including the warranties of merchantability or fitness for a particular purpose In no event shall AZI be liable for consequential and or incidental damages The effective warranty begins on the date of purchase by or lease to the first end user owner Keep the dated bill of sale or invoice for evidence of the effective warranty date when warranty service is requested In the event that any questions or problems should arise in the use or application of your Computrac MAX 5000XL unit call AZI Customer Service or your technical sales representative at 800 528 7411 or 602 470 1414 Page 19 of 20 MAX 5000XL Web Server User s Manual TRADEMARK AND COPYRIGHT PROTECTION Computrac MAX Arizona Instrument AZI and the stylized AZI are all registered trademarks of Arizona Instrument LLC Instrument firmware is copyright protected All specifications subject to change without notice Internet Explorer and Excel are registered trademarks of Microsoft Corporation in the United States and other countries The MAX 5000XL uses the Graphics Interchange Format as part of its Ethernet interface The Graphics Interchange Format is the Copyr
18. tart 7 Memory Start 8 Memory Start 9 Memory Start 10 TEST RESULTS hal illl Select memory starts to download Use Shift key to select range Use CSV file extension when saving files Copyright 2005 Arizona Instrument LLC Memory starts can be downloaded from the instrument or can be uploaded to the instrument Thus memory starts can be retrieved from one instrument and saved to another Typically set up one MAX 5000XL with the desired memory starts transfer the memory starts to the PC and then transfer the memory starts from the PC to other instruments Memory start data is saved in a comma delimited format which can be read by Excel or a compatible spreadsheet program Although memory starts can be edited in Excel it is not recommended Page 6 of 20 MAX 5000XL Web Server User s Manual 2 4 Test Results To view test results select TEST RESULTS in the left sidebar Ai MAX SOOQOXL AZ Preferred Customer SN 500117 CALIBRATION REPORT LCD VIEW LACTOSE MONOHYD 04 Sep 2007 MEMORY STARTS LACTOSE MONOHYD 04 Sep 2007 LACTOSE MONOGHYDI 04 Sep 2007 TEST RESULTS LACTOSE MONOHYD 04 Sep 2007 LACTOSE MONOHYD 04 Sep 2007 TARTRATE 04 Sep 2007 TARTRATE 04 Sep 2007 TARTRATE 04 Sep 2007 TARTRATE 04 Sep 2007 TARTRATE 04 Sep 2007 DRIFT 04 Sep 2007 WEIGHT 04 Sep 2007 WEIGHT 04 Sep 200 WEIGHT 04 Sep 2007 WEIGHT 04 Sep 2007 WEIGHT 04 Sep 2007 WEIGHT 04 Sep 2007 WEIGHT 04 Sep 2007 Select test resul
19. ts to download Use Shift key to select range Use C5V file extension when saving files Download Tests Download Test Graph Data Copyright 2005 Arrzona Instrument LLC Test results can be downloaded from the instrument Test data is saved in a comma delimited format which can be read by Excel or a compatible spreadsheet program Graph data contains only the data points that are used by the instrument to generate the graph the actual visual graph is not downloaded Page 7 of 20 MAX 5000XL Web Server User s Manual The Web Server special feature is set up at the factory or can be upgraded in the field Please contact AZI Customer Service at 800 528 7411 or 602 470 1414 for activation instructions Once activated follow the steps below Make sure the instrument is turned on and connected to an active Ethernet connection Ethernet Setup m UR NP screen press MENU SETUP ETHERNET SETUP NAME MAX 5000XL This menu provides the necessary icio OBTAIN IP ADDRESS Automatic controls to interface with a local area that you have purchased for the MAX 5000XL A PG can then access the MAC ADDRESS 00 08 50 00 00 75 MAX 5000XL from the intranet Generally the MAX 5000XL cannot STATUS Initialized be viewed on the Internet because of company firewalls but it is possible and requires a registered IP address NAME and PASSWORD The NAME and PASSWORD can be used to Fe TT TTTW CO EVA ty ayy a restrict access to the

Download Pdf Manuals

image

Related Search

Related Contents

Mod: DC502/PS-N  BrightLink 455Wi+  Delta PAN24-PC1 Installation Guide  MTD 410R Cultivator User Manual  User Manual - A New Personal Encryption Tool Based on Elliptic  CASDAR Flexi-sécurité - Chambre d`agriculture de la Manche    Sanyo 6-inch User's Manual  manual da multimulher  

Copyright © All rights reserved.
Failed to retrieve file