Home

VPIS V2 - Schneider Electric

image

Contents

1. Technical leaflet VPIS V2 PE58178 Voltage indicator PE58142 Open seal PE58143 PE58144 VPIS VO surge protection PE58145 Cover joint not available as spare part 01 Voltage presence indicating system for MV cubicles Description m The VPIS V2 is a self powered voltage presence indicating system in compliance with the IEC 62271 206 standard Connectors on the front panel allow the use of a phase comparator see corresponding section in the document m Extended lifetime of LEDs on the front panel Compatibility with existing MV network devices for replacement The VPIS V2 consists of two parts o the surge protection part always connected o the voltage presence indicating part replaceable for maintenance m Retrofit no change necessary for the replacement of a VPIS V1 production from 01 2000 02 2009 with a VPIS V2 However a special open seal is necessary Supplied with each VPIS V2 for installation on an existing wiring harness Thresholds E In compliance with the IEC 62271 206 standard the indicator lamp outputs of the VPIS are lit or flashing when the network voltage is gt 45 of the rated voltage IEC 62271 206 Equivalent Status of VPIS percentage of percentage indicator lamps network voltage U of rated voltage V Phase to phase Phase to earth 10 17 Extinguished Voltage value at VPIS input 45 78 Lit or flashing The
2. positioned correctly The guides should be aligned at the time of connection If the positioning is not correct this causes a poor electrical connection Incorrect assembly Correct assembly Thrust stop PE58153 09 18 01969 2403 VPIS 2413 VPIS VO 7 4 pA Enclosure mounting Place in position and tighten the 4 enclosure mounting screws Pozidrive no 1 or flat 4 5 screwdriver Tighten the screws until the thrust stops in each corner of the protection enclosure are in contact with the indicator part Warning do not tighten screws beyond what is mentioned above otherwise the seal will be crushed and so tightness of VPIS will be degraded Installation of the cover joint on the VPIS V2 Install the joint concealing the phase comparator test points Press on it firmly to place it correctly in position DE59155 Technical Leaflet VPIS V2 Used electronic products must be deposited in the appropriate collection points Schneider Electric Industries SAS 35 rue Joseph Monier CS 30323 F 92506 Rueil Malmaison Cedex France Tel 33 0 1 41 29 70 00 RCS Nanterre 954 503 439 Capital social 896 313 776 www schneider electric com ENMED309037EN 08 Phase concordance unit Via the VPIS the phase concordance unit allows a check of the phase concordance between 2 energised functional input units on the same panel It is a way of making sure that all three cables are each connected to the correspond
3. re used for the phase of remounting on the VPIS V2 Installation of the seal on the wiring harness Note this operation is necessary only in the case of replacement of a VPIS V1 with a VPIS V2 For the replacement of a VPIS V2 the seal is already assembled in factory on the wiring harness This operation is therefore not necessary Note the seal available with the VPIS V2 for the replacement is of the open type so as to be able to be mounted on an existing wiring harness cable Insert the wiring harness wires in Pass the tab behind the connector clip the opening parts of the seal wireway PE58175 NB the seal should be handled with care E Do not make the cable slide more than 10 cm in the seal E Do not run stripped wires in the seal E Do not run wires with crimped contacts in the seal Installation of the seal wiring harness assembly on the protection part Insert the wiring harness connector in Insert the seal in its housing the protection part of the VPIS V2 PE58162 Note check that the seal is correctly positioned over the entire perimeter of the enclosure to ensure satisfactory tightness Assembly of the indicator on the surge protection part Insert the two parts of the VPIS V2 over one another indicator part over the protection part During the assembly phase the wiring harness stays in position in the protection part Note use the plastic guides to ensure that the two items are
4. ection part Note use the plastic guides to ensure that the two items are positioned correctly The guides should be aligned at the time of connection If the positioning is not correct this causes a poor electrical connection Correct assembly Incorrect assembly Thrust stop PE58153 ee 09 34 06106 09 18 01969 7 4 pA 52403 vpig 09 18 01969 2413 VPIS VO 7 4pA 03 VPIS 13 VPIS VO Enclosure mounting Place in position and tighten the 4 enclosure mounting screws Pozidrive no 1 or flat 4 5 screwdriver Tighten the screws until the thrust stops in each corner of the protection enclosure are in contact with the indicator part Warning do not tighten screws beyond what is mentioned above otherwise the seal will be crushed and so tightness of VPIS will be degraded Installation of the cover joint on the VPIS V2 Install the joint concealing the phase comparator test points Press on it firmly to place it correctly in position Technical Leaflet VPIS V2 PE58166 PE58164 PROTECTION 69 34 06106 09 34 0388 47 2 pA VPI62408 VPIS VPI62418 VPIS VO PE58151 PROTECTION 09 34 06106 PE58179 PE58159 PE58176 PE58154 07 Replacement of a VPIS V1 with a VPIS V2 Dismounting the VPIS V1 wiring harness Press on the wiring harness connector clip and then pull on the connector to disconnect it from the VPIS V1 Note the wiring harness will be
5. ensures that the screws are held in place in the protection part and prevents them from coming out of the enclosure Installation of the cover joint on the VPIS V2 Install the joint concealing the phase comparator test points Press on it firmly to place it correctly in position Technical Leaflet VPIS V2 PE58150 PE58163 PE58164 PROTECTION 09 34 06106 Plastic guides 09 34 03882 47 2 pA VPI62408 VPIS VPI62418 VPIS VO PE58151 PE58179 PE58154 06 Replacement of the VPIS V2 indicator The indicator should be replaced if one or more indicator lamps are no longer lit when the MV network voltage seems to be present NB never disconnect the wiring harness protection part when the MV network voltage is present Dismounting the indicator Loosen four screws on protection enclosure Pozidrive no 1 or flat 4 5 screwdriver Note when the seal is placed in position it ensures that the screws are held in place in the protection part and prevents them from coming out of the enclosure Separate the two parts of the VPIS enclosure and put aside the defective indicator Note the protection part is kept and its wiring harness should remain in position during the dismounting phase Assembly of the new indicator on the surge protection part Insert the new indicator on the existing protection part During the assembly phase the wiring harness stays in position in the prot
6. flashing frequency increases depending on the level of the network voltage At rated voltage the indicator lamps seem to be lit steadily Customer benefits E Voltage presence indicating system in compliance with the IEC 62271 206 standard and also with the old IEC 61958 standard E 9 references available to adapt to all applications E Voltage output option for source changeover switch application a arctar LO LO e2 LO W a DE59552 Technical Leaflet VPIS V2 i Connection m The VPIS V2 includes a 4 pin connector for connection to the cubicle coupling elements 1 pin for connection to earth and 1 pin for connection of the coupling elements on each phase O The wires used have a cross section of 1mm2 with an outside diameter ranging between 2 5 mm and 2 9 mm o The connector contacts are Minifit 5556 type o The connector housing is of MOLEX 39 01 4040 or 39 01 4041 type m The optional voltage output cable supplied with the VPIS VO for the Flair 22D 23D 23DM and VD23 is 1 m long MOLEX 79516 type cable the output signals of this cable are of positive half wave type for each phase L1 L2 and L3 Two extensions of length 1m and 2 m are available if needed for the optional voltage output o EMS58422 extension cable for connection VPIS VO VD23 Flair 2xD length 1m Oo EMS58423 extension cable for connection VPIS VO VD23 Flair 2xD length 2 m m PE58146 PE58147 Installation recommendat
7. hoice With VO VP162413 VP162414 VP162416 VP162417 VP162418 50 60 Hz 2 5kV 5kV 4 kV 7 kV 8 kV 15 kV 10 1 kV 24 kV 17 kV 24 kV Second Without VO VP162405 VP162407 choice With VO VP162415 VP162417 50 60 Hz 5 kV 11 kV 10 1 kV 24 kV Ringmaster First Without VO_ VPI62401 VP162401 VP162403 VP162403 choice With vo VP162411 VP162411 VP162413 VP162413 50 60 Hz 3 4 kV 7 5 kV 3 4 kV 7 5 kV 7 1 kV 16 kV 7 1 kV 16 kV Second Without VO VP162402 choice With VO VP162412 50 60 Hz 5 8 kV 10 kV Genie First Without VO VP162401 VP162402 choice 50 60 Hz 4 5 kV 11 kV 7 KV 15 kV Second Without VO VP162401 choice 50 60 Hz 4 5 kV 11 kV SM6 36 First Without VO VP162404 VP162404 VP162406 VP162406 choice With VO VP162414 VP162414 VP162416 VP162416 50 60 Hz 13 kV 24 kV 13 kV 24 kV 26kV 50kV 26 kV 50 kV Second Without VO VP162403 VP162403 VP162405 choice With VO VP162413 VP162413 VP162415 50 60 Hz 9 kV 17 kV 9 kV 17 kV 21 kV 35 kV CAS 36 First Without VO VP162406 VP162407 VP162408 VP1I62409 VP1I62409 choice With VO VPI62416 VP162417 VP162418 VP162419 VP162419 50 60 Hz 8 5kV 14 kV 12kV 20kV 17kV 30 kV 21kV 42 kV 21 kV 42 kV Second Without VO VP162407 VP162408 choice With VO VP162417 VP162418 50 60 Hz 12 kV 20 2 kV 17 kV 30 kV MCSet 1 2 3 First WithoutVO VPI62403 VP162404 VP162407 VP162407 VP162408 Nex 17 choice 50 60 Hz 2 kV 4 kV 3 kV 6 3kV QkV 17kV Q9kV 17kV 13 kV 25 kV Ne
8. ing phase of the panel Balanced phase the phase concordance light remains unlit m Unbalanced phase the phase concordance unit light is lit Phase concordance Functional unit Functional unit Compatibility Corrective actions unit no 1 no 2 result 8 hoa V1 000 OK Phase concordance yo O99 d Use a phase concordance unit unit V1 V2 Ref 51191954FA Replace VPIS V1 by VPIS V2 V2 and use a phase concordance unit V2 0 V2 OR use a phase concordance unit V2 with adapter TE VAENE ETA Replace both VPIS V1 units o g by VPIS V2 units unit V2 EAA without adapter OR test with the phase Ref VPI62421 concordance unit V1 OK Comparison between a VPIS V1 and VPIS V2 is also possible with using an adapter on VPIS V1 side and a VPI62421 phase concordance unit Adapter stand alone for VPIS V1 m EMS58434 2 5 7 7 kV m EMS58435 8 8 23 kV Kit including a phase concordance unit adapter m EMS58431 15 20 kV ERDF m EMS58438 8 8 23 kV Phase Functional unit Functional unit Compatibility Corrective actions concordance unit no 1 no 2 result S CS X Replace both VPIS V1 units by V1 VPIS V2 units OR test with the phase concordance unit V1 The adapter must be used on Phase concordance v1 OK VPIS V1 side uni
9. ion It is important to respect certain rules regarding the installation of the wiring harness It must be fixed so that in case of condensation water flowing along the wires is guided to the ground and not to the wiring harness input of the VPIS DE59550 Power supply source changeover application m The VPIS V2 is designed to be connected directly to the new VD23 voltage relay The VPIS V2 connectors are therefore adapted to those of the VD23 m The VPIS V2 can also be connected to the old generation voltage relays of VD3H type using a specific adapter ref RCL62454 DE59553 Characteristics PE58149 Radiated interference Emitted radiation IEC 62271 1 6 9 1 2 30 MHz 1 GHz Immunity test Immunity to electrostatic discharge Radiated radio frequency IEC 61000 4 2 IEC 62271 1 6 9 2 1 IEC 6100 4 3 6 kV contact discharge 8 kV discharge in air 10 V m 80 AM at 1 kHz electromagnetic field IEC 62271 1 6 9 2 1 80 MHz to 3 GHz immunity Immunity to electrical fast IEC 6100 4 4 2 kV mains power supply transients IEC 62271 1 6 9 2 3 Slow damped oscillatory wave IEC 6100 4 18 1kV in differential mode immunity IEC 62271 1 6 9 2 4 2 5 kV in common mode Radiated magnetic field IEC 6100 4 8 Permanent magnetic field at 100 A m immunity IEC 62271 1 6 9 2 1 1000 A m during 1s Immunity to voltage dips and IEC 6100 4 11 100 reduction during 5 and 50 periods short interr
10. s correctly positioned over the entire perimeter of the enclosure to ensure satisfactory tightness Assembly of the indicator on the surge protection part Insert the two parts of the VPIS V2 over one another indicator part over the protection part During the assembly phase the wiring harness stays in position in the protection part PROTECTION 09 34 06106 Note use the plastic guides to ensure that the two items are positioned correctly The guides should be aligned at the time of connection If the positioning is not correct this causes a poor electrical connection 62408 vers 09 3403982 47 2 pA ven VPI62418 VPIS VO Correct assembly Incorrect assembly Thrust stop PE58154 PE58153 ee 09 34 06106 09 34 06106 vels 09 18 01969 09 18 01969 amp Zee VPIS M13 VPIS VO 7 4pA 2413 VPIS VO PER o aa Status of VPIS LEDs Status of VPIS LEDs L3 Phases L1 OFF powered 19 OFF L3 OFF OFF L1 L2 L3 Enclosure mounting Place in position and tighten the 4 enclosure mounting screws Pozidrive no 1 or flat 4 5 screwdriver Tighten the screws until the thrust stops in each corner of the protection enclosure are in contact with the indicator part Warning do not tighten screws beyond what is mentioned above otherwise the seal will be crushed and so tightness of VPIS will be degraded Note when the seal is placed in position it
11. st be replaced in the event of E VPIS cable damaged m Substation flooded Dismounting the VPIS V2 Loosen four screws on protection enclosure Pozidrive no 1 or flat 4 5 screwdriver Separate the two parts of the VPIS enclosure Pull the tab of the seal to the rear to remove it from the connector clip and Remove the seal from its housing pass it above the latter to obtain access to the connector PE58155 DE58156 PROTECTION 69 34 06106 90L90 E 60 NOILIJIOYJA p NA 34 03887 vP62408 VPIS VPI62418 VPIS VO 41 pA Note if the seal is of the closed type it remains fixed on the wiring harness and will be re used at remounting The open type seal supplied with the VPIS V2 is not used in this case Recovery of the existing wiring harness Press on the connector clip and at the same time pull on it to disconnect it from the VPIS PE58157 PE58158 Put aside the two VPIS V2 elements in fault condition and replace them with those of a new VPIS V2 Then mount the new VPIS V2 PE58164 PE58151 PE58179 Technical Leaflet VPIS V2 Ta Mounting the new VPIS V2 Installation of the seal wiring harness assembly on the protection part Q Pass the tab behind the connector clip PE58173 Insert the wiring harness connector Insert the seal in its housing in the protection part of the VPIS V2 PE58174 PE58172 Note check that the seal i
12. t V2 with adapter Ref EMS58431 or EMS58438 V2 OK Do not use the adapter Safety warning m The VPIS indication alone is insufficient to ensure that the system is power off if operating rules require then appropriate voltage detectors in compliance with the IEC 61243 1 IEC 61243 2 and IEC 61243 5 standards must be used for this purpose E In certain situations of high luminosity it may be necessary to improve the visibility of the indicator lamps for example by creating shade around them m Never disconnect the surge protection part when the MV network voltage is present For more product information consult the phase concordance unit user s manual NT00214 FR EN xx As standards specifications and designs change from time to time please ask for confirmation of the information given in this publication A PEFC 10 31 1247 Publishing Schneider Electric Industries SAS Design Schneider Electric Industries SAS XX This document has been Printing Altavia St Etienne Made in France 4S printed on recycled paper 02 2014 ART837635 Schneider Electric Industries SAS All rights reserved
13. uptions IEC 62271 1 6 9 3 3 60 reduction during 50 periods 30 reduction during 1 period In storage humidity dry heat and cold Temperature variation cyclic with Low temperature 40 C 240 min Plateau temperature 20 C 35 min High temperature 85 C 180 min Variation 2 C min Cycle time 870 min Complete test duration 1000 hours In operation Temperature variation IEC 60068 2 14 Low temperature 25 C High temperature 85 C Variation 0 5 C min Plateau 3 hours Number of cycles 2 Impacts De energized IEC 61958 1 IEC 60068 2 75 2 Joules 3 impacts in the weakest places Technical Leaflet The range of use for each VPIS V2 depends on Service voltage network frequency and the switchgear capacitor Here are typical range of use for 50HZ 60Hz In case of use only for 50Hz or only 60Hz the range of use could be expand please consult the switchgear offer manager Theses references are no longer manufactured 3 kV 6 kV 10 kV 15 kV 20 kV 30 kV 40 kV SM6 24 First Without VO VPI62403 VP162404 VP162407 VP162407 VP162408 choice With VO VP162413 VP162414 VP162417 VP162417 VP162418 50 60 Hz 2kV 4kV 3 4 kV 6 3 kV 9 kV 17 kV QKV 17 kV 13 kV 25 kV Second Without VO VP162405 VP1I62406 VP162408 choice With VO VPI62415 VP162416 VP162418 50 60 Hz 4 kV 8 kV 7kV 13kV 13 kV 25 kV RM6 First Without VO VPI62403 VP162404 VP162406 VP162407 VP162408 c
14. x 24 Second Without VO VP162405 VP162406 VP162408 Evotech choice 50 60 Hz 4kV 8kV 7kV 13kV 13 kV 25 kV F400 F400 24 F400 Xe F400 36 kV First Without VO VP162402 VP162404 VP162405 VP162406 VP162407 VP162407 choice 50 60 Hz 4kV 6 2kV 9 KV 13kV 13 kV 19kV 16 kV 27kV 26kV 60 kV 26 kV 60 kV Premset First Without VO VPI62403 VP162404 VP162406 VP162406 choice With VO VP162413 VP162414 VP162416 VP162416 50 60 Hz 2 5 kV 5 5 kV 4 kV 7 kV 8 kV 15 kV 8 kV 15 kV PIX STD First Without VO VPI62403 VP162405 VP162407 VP162407 VP162408 PIX MCC choice With VO VP162413 VP162415 VP162417 VP162417 VP162418 50 60 Hz 2 1kV 4kV 4 6 kV 8 4 kV 9 3kV 17 6kV 9 3kV 17 6kV 13 8kV 25 5kV Second Without VO VPI62406 choice With VO VP162416 50 60 Hz 6 6kV 12 1kV FBXC RE First Without VO VPI62403 VP162403 VP162405 VP1I62406 VP1I62406 R T1 choice With VO VP162413 VP162413 VP162415 VP162416 VP162416 50Hz 3 kV 7 kV 3 kV 7 kV 6 kV 13 kV 10 kV 24 kV 10 kV 24 kV FBX T2 CB First Without VO VPI62406 VP162406 VP162408 VP1I62409 VP162409 choice With VO VP162416 VP162416 VP162418 VP162419 VP162419 50Hz 3 kV 7 kV 3 kV 7 kV 6kV 13 kV 12 kV 24 kV 12 kV 24 kV PE58150 PE58164 Technical Leaflet VPIS V2 oa Dimensions 70 lt 40 Schneider P Electric POs oe Aperture 32 x 53 Maintenance Replacement of a complete VPIS V2 The whole VPIS V2 indicator protection mu