Home
IRIS - HPLC Spectral Processing Software
Contents
1. ccc ee trees ee ee ttn eeeeeeeeeee ania 31 Viewing a Spectral Method cecceccccsseeeeeeeeeeeeaaaaeteeeeeeeeeeeaeaaaaeeees 33 How do modify the parameters values stored in a Chromatogram s Spectral Method and a Process Spectral Method 37 Editing the Default Method to set the default initial conditions of a new method ee eee eee e eee eeeeeeee ee enna 39 Chapter 2 Enhanced Security cscccssseeeessesseeseeeeseeseeeneeeeenneees 42 Enhanced Security anoa a Rawle dat alec eee eee 43 User Management visisaccretadatmn vadhetnaesmnedl aetduti siete amen aser ied 44 User P rMiSSiOns cccccccsscecccecceeceeceeeeeceeeeeeseeaeeeeseesaseseesaneesesanaes 44 Audit Trails peie oiea aa totais E ata tae EAEE e p OTEA 45 What information is captured in an Audit Trail 46 Entering Audit Trail Information nee eee 47 Viewing an Audit Trail cceiveaceieliseeidesie bee eye lees 48 Electronic Signatures 200t0 0 cninesiali eae Ain ee ae 53 Electronic Signature Support in IRIS cece eee cess eeeteeeeeee eter arena 53 Chapter 3 Opening and Viewing ChromatogralmsS csssssssssseees 54 WNTFOCUCUION iaaea attests Sigs ant eet AAE tee EE a A aa 55 Opening a Chromatogram 00 0 0 eee e eerie reer eae 56 Viewing Chromatograms eececee eee ee eeee ena EEE 59 Working with the Chromatogram pane eeceeeeeeeeeeeeeeeeeee eee aaeaeeees 59 Obtaining Information about a Chromatogram
2. 123 Iris HPLC Spectral Processing Software Data Tree The Data Tree displays a list of opened chromatograms From the Data Tree you select the required chromatogram for the contour map Only one chromatogram can be selected and displayed on this view at a time File Edt View Actions Took Heb ih 3 Pa f Helsiaioie atl OTE o r LE CARAGA B21 Chrom Spectra Contour Map Spectr a0 Congare k Operators Custom Views T o N JUIL 11 22 33 44 65 66 77 6a 124 Chapter 5 Viewing the Data Contour Map Pane This pane displays the contour map of a chromatogram that is selected on the Data Tree The display includes a crosshair cursor which is used to select a point on either the retention time axis or the wavelength axis and the relevant chromatogram and spectrum will be shown in the corresponding panes below The contour levels show the absorbances 20 225 250 a 275 300 ns 2 350 376 3 125 Iris HPLC Spectral Processing Software Chromatogram Pane The Chromatogram pane displays the chromatogram from the wavelength axis point selected on the Contour Map pane To display a chromatogram on this pane simply float your mouse pointer over the Contour Map and the chromatogram from that point is temporarily displayed on the Chromatogram pane If you want to temporarily extract a chromatogram from the Contour Map just double click on an area in the Contour Map and the chrom
3. 322 Printing and Presentation Options eener 323 ANNONS aeieea cad aE tenes AAE VENE a T a TE Aa E 324 Table Of Contents How do I add an annotation eee 324 How do modify an annotation ee 325 How do I delete annotations nee 325 Copying IRIS Images to other Locations 326 How do export a chromatogram or spectrum in numerical format for use in spreadsheet programs 326 Printing Chromatograms and Spectra from IRIS esccenceercrne 327 What information is included on printouts ee eeee cette eee 328 Tell me about the Print dialog seeen 330 How do print the current view or operation ccecce 340 How do print the contents of a single pane from any of the IRIS views 341 How do print a chromatogram and its associated apex spectra 347 Appendix 1 Calculation Algorithms c cssseesseseeeeseeseeeeeeeeeneeees 349 Calculation Algorithms cse ivetieat dt atie tt dient 350 IRIS Peak Purity AIQOritnim eect teeeeee trees aes atneeneeeeeeees 350 Euclidean Distance Algorithm eeen 351 E TT 352 Chapter 1 Introduction Iris HPLC Spectral Processing Software Introduction IRIS is a spectral application program designed for use with TotalChrom 6 3 1 or higher and the Series 200 HPLC System equipped with a Series 200 PDA Detector Photo Diode Array With IRIS you can process manipulate and display spectral data associated with chromatograms obtained using the Series 200 PDA In co
4. Butyl Benzene Not Found Display Apex C Spectrum Baseline I Library 400 C Library Baseline Login manager a To examine the Retention Time Adjustment values at different wavelengths gt Enter a new value for the Minimum Wavelength and or Maximum Wavelength The Wavelength Maximum value labels are updated for every peak in the chromatogram To examine the effect of using baseline corrected spectra on the Retention Time Adjustment values gt Check Baseline Correct Spectra The Wavelength Maximum value labels are updated for every peak in the chromatogram 288 Chapter 8 Performing Operations on Chromatograms To save the results and parameters used in the calculation gt The corrected retention times can then be saved to the chromatogram s result file by selecting File gt Save Results from the IRIS menu bar In addition when making this selection the parameters used to correct the retention times are also saved to the chromatogram s spectral method file To display the Retention Time Adjustment results in the Main or Chrom Spectra view 1 Select Actions gt Label Chromatograms 2 Select Retention Time Adjustment from the list of available labels To review for any chromatogram previously determined Retention Time Adjustment values and the parameters used gt Select this chromatogram again on the Retention Time Adjustment operation The saved results and the calculation paramete
5. If a spectrum is right clicked on this command allows you to name and save the spectrum as uv file If a chromatogram is right clicked on this command allows you to name and save the chromatogram with a RAW extension Displays a Print dialog from where you specify which details you want to print from the current view and which printer you want to use Toggles all the spectra belonging to the chromatogram right clicked on to the same color as the chromatogram all other spectra are then turned grey This option is enabled only when a chromatogram is right clicked on Adds removes the baseline spectrum for the spectrum right clicked on in the Data Tree Baseline spectra are identified by the retention time of the spectrum followed by the word base This command is enabled if a spectrum is right clicked on and disabled for a baseline spectrum Displays the Spectral Baseline correction dialog This option is enabled if a chromatogram is right clicked on Chapter 1 Introduction Show scale View Method TotalChrom Reprocess Graphic Method Edit Displays the Y axis scale for the spectrum or chromatogram right clicked on This command is enabled if the current graph is displayed as overlaid and normalized and so by default the scale is blank Opens the Method Editor dialog as read only and displays the parameter values in the chromatogram s spectral method The chromatogram s spectral method ha
6. When Manual is selected enter the required value in the entry field by either typing directly or using the spin buttons When Manual is first selected the minimum absorbance value calculated by the Auto function is displayed in the Manual threshold field 246 Chapter 8 Performing Operations on Chromatograms Summary of Operation Spectral Standard Confirmation The summary below shows you how to perform the Spectral Standard Confirmation operation on a chromatogram and then save the results To confirm the identity of peaks by comparing to a standard chromatogram 1 From the Views tree select Operations gt Spectral Standard Confirmation The Spectral Standard Confirmation operation displays From the Data Tree click on the chromatogram that contains the named peaks that you want to verify against a standard chromatogram The selected chromatogram appears on the Chromatogram pane with a vertical cursor that snaps to the nearest named peak Note If the selected Chromatogram has no named peaks a message is displayed on the chromatogram graph stating Selected chromatogram has no named peaks and the Standard Chromatogram pane and Result pane are blank 3 Select a standard chromatogram from the Select a Standard Chromatogram dialog box that automatically appears if you have not already performed spectral standard confirmation on the selected sample OR If this dialog does not automatically appear you can click o
7. Chapter 8 Performing Operations on Chromatograms Results Pane This pane displays the items that appear checked on the Display List When Apex is checked on the Display List this pane shows the apex spectrum for the peak currently selected on the Apex Optimized Chromatogram pane The apex spectrum is labeled with the wavelength actually used in extracting that region of the chromatogram This label will show the actual extraction wavelength It is then possible to observe the difference between the extraction wavelength and the true optimum wavelength if the wavelength cannot be optimized e g the peak is not baseline separated from the earlier peak 305 Iris 306 HPLC Spectral Processing Software Display List You use the Display List to select the information you want displayed on the Results pane When items appear checked on this list they are displayed in the Results Pane Meanwhile unchecked items are not displayed The following items are available for selection on the Display List Apex When this item is checked the Peak Apex Spectrum pane displays the spectrum taken at the maximum point of the selected chromatogram peak The peak maximum of the spectrum is labeled with the wavelength and absorbance Baseline When this item is checked the baseline spectrum for the selected chromatogram peak is displayed on the Peak Apex Spectrum Chapter 8 Performing Operations on Chromatograms How do
8. Enabled at all times Displays the opening page of the HTML Help system iris chm Enabled at all times Toggles the tool tips on and off Enabled at all times Default is on Goes to www perkinelmer com Enabled at all times if there is a web browser installed and connected to an ISP 23 Iris HPLC Spectral Processing Software Menu Command Description About Displays the About dialog Enabled at all times 24 Chapter 1 Introduction IRIS Tool Bars In IRIS there are three default tool bars located below the menu bar The tool bars contain icons for standard interactions that will be performed frequently The default tool bars are as follows Main Tool Bar The Main Tool bar contains the following commands Associated menu Description command Ss Open Chromatogram Enables you to open a chromatogram and add it to the Data Tree Open Spectrum Enables you to open a spectrum and add it to the Data Tree Closes the Closes the currently selected items in the Data tree selected items in the Data tree e Enables you to review the information associated with a file B Swe Saves current Saves current changes to a file to a file C Sesnv pcrmorenrte ronson mopo eese o E C Baseline Corrected Determines whether spectra are shown in their baseline Spectra corrected state or not Label Chromatograms Enables you to choose the labels to be bea on i ae as Enables you to add or edit
9. Spectra 101 G Graphic Method Edit 73 H Hiding Spectra 86 I Individual Spectra 76 Individual Previously Stored Spectra 85 Information 16 63 Spectrum 16 87 IRIS menu bar 316 320 IRIS Menu Bar 15 IRIS User Interface 7 IRIS Views 106 L Labeling Chromatograms 65 LC 318 Library 153 Library Match 168 Library Spectra 76 Main View 107 Menu 15 Menu Bar 15 Minimum Absorbance 212 modify a Chromatogram s Spectral Method 37 modify a Process Spectral Method 38 modify the parameters values 37 N Normalization 70 Normalize All 92 Normalize Point 98 Normalize Y Only 94 Normalizing 91 numerical format 326 O Offset Normalize 97 Opening a Chromatogram 56 Operations 9 P Panes 14 Peak Library Search 263 Peak Purity 201 Summary of Operation 211 Index Peak Purity Algorithm 350 Preferences Click Preferences button 316 320 Preferences Click 316 Preferences Click 320 Preferences button Preferences Click 316 320 Preferences button 316 Preferences button 320 Print 318 would like 316 320 Print 316 Print 320 Print What 316 320 Printer Select 316 320 Printing Chromatograms and Spectra 327 Process Spectral method 315 Process Spectral Method 31 PT 318 R Range Box 83 Removing Spectra 86 Reprocess 6 73 Retention Time Adjustment 276 RT 318 Save Spectra 102 Save Results 309 Saving the Results 309 SC 318 Scaling
10. The Format Graphs dialog closes and the new limits are applied 131 Iris HPLC Spectral Processing Software Spectra 3D View The Spectra 3D View is intended to help you explore complex chromatographic data This view gives you a wide array of tools for visual investigation of chromatographic and spectroscopic features Although it does let you view spectral and chromatographic data during analysis the data cannot be stored for use in other areas of the IRIS program When a chromatogram is selected on the Data Tree and the Spectra 3D View is selected the spectrum and chromatogram positions come from the projection of the mouse cursor position down onto the plane of the perspective outline box Once you click on the 3D display at the point of interest the cursor position is identified by a cross hair marker and is defined in the information bar at the bottom of the Spectra 3D window on the X time axis the Y absorbance axis and the Z wavelength axis Tell me about the Spectra 3D View File Edit View Actions Tools Help Saidealals a yela A 12 e OFS O Spectra 3D View oS Main view Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views example 2 identified but with coeluti a URED DE Waa waaa OU poaa waaa wuy voa wawa OU PD ww aaa IA 14 22 33 44 55 66 77 88 Login manager Figure 5 4 The Spectra 3D View 132 Chapter 5 Viewing the Data The Spectra 3D View i
11. cccccceeceeeseeteeeeeeeeeeeee nea tneeneeeeees 298 Rules for setting the wavelength for a peak 299 Tell me about the Apex Optimized Chromatogram operation 300 How do modify the parameters that are used to create a chromatogram with the optimum wavelength set for each peak eect eee eetee eee saaaeeeeeenees 307 Summary of Operation Apex Optimized Chromatogram 308 Saving the Results of a Calculation c cece erenneren 309 How IRIS saves Information to TotalChrom cceeeeeeeeeeeeeeees 310 How do include the results of chromatographic operations performed by IRIS AutoCalc in a TotalChrom report 312 Chapter 9 AutoCalc Automating Arithmetic Operations Extractions and Apex Spectra Printing 313 Whats Auto Cale onanii nenii adentar a aaa aa AE 314 Points to consider when using AutoCalc for automated operations in TotalChrom ccccccceeeeeeeeeeseeeeeeeeeeeee ae anes 315 How do use AutoCalc to automatically perform the desired operations during a TotalChrom sequence 317 Command Line Examples cee cece ee te eeeeee eee aenteneeeeees 319 Using AutoCalc to print automatically the Apex Spectra display for each sample in a running Sequence 320 Steps you must perform before you can automate the printing of chromatograms annotated with apex specta320 Chapter 10 Printing and PresentationS ssssssss es11s
12. cceceeeceeeeteeeeeeeeee eae 63 Labeling Chromatograms a Aents naiinis e aaa a a a ai 65 Scaling Chromatograms cece tritt tt ttt EEE EEEEEEEEEEEEEEEEEEE eae 66 How do I visually specify an area of the display to zoom into using the Box Zoom function ceecee 66 How do I view and change the axis range for a particular chromatogram cece eect eeeeee tease nene Ennen rett 67 How do use the Autoscale tools eneee 68 How do zoom in a continuous fashion aeee 69 How do use the use the Normalization commands to find subtle differences between chromatographic peaks 70 How do close a Chromatogram cccceeeeeeeetteeeeeeeeeeeeesaeeteeeeeeeees 72 Iris HPLC Spectral Processing Software Initializing a TotalChrom Environment with an IRIS Chromatogram 73 Chapter 4 Viewing Spectra ccccsssseeeesseseeeeeeeseeeseeeesseeeeneeeeeneneeeees 74 Introductio 2 5 feceyatscs te eneseavnea cuts i aa ea ee eee neta A re eae 75 Spectral FOrmMats c2 fre cehaeed conte ni o aa a i aes 76 Viewing a Sp CtruUM 0 eee cece eerste a A e a aaia 77 Viewing Chromatographic Spectra esssiseesssesisiirreeeeerisirrrreeeeeinrrns 78 Viewing Individual Previously Stored Spectra 85 Removing Spectra and Hiding Spectra from the Data Tree 86 Removing Spectra from the Data Tree eccerre 86 Hiding Spectra from Being Displayed 86 Obtaining Information on a Stored Spectrum e eee ceeeeeee eee eeeeeeee
13. f ma 8 z Ha Hit Distance Threshold CO ANNANN AAAY ENANN NANA AJNEANU ANEA ANKANA AA AJAA 44 22 33 44 65 6 6 re 88 zi example1_well_separated001 example 4 identified butyl be IV Baseline Conected Library List ma Sample EthylBenzene EthylBenzene propyl benzene PropylBenzene EURE SAUE EUN S AEAEE ESRA ALERTAN ATN PropylBenzene 220 275 330 385 Toluene Login imanager amp 4 Figure 8 6 The Peak Library Search operation 263 Iris HPLC Spectral Processing Software Identifying Chromatographic Peaks In order to perform a Peak Library Search you must first select a chromatogram from the Data Tree At this point you may be prompted to select a list of libraries to search if a search has not been previously performed on the chromatogram If you have already performed a search on the chromatogram IRIS uses the previously defined set of libraries for the search At any time however you can modify the list of libraries that are used in the search by clicking on the Library List button which is located in the right hand portion of the Peak Library Search operation Once you have selected a chromatogram and built a list of libraries to be searched IRIS automatically searches the specified spectral libraries for a match to the apex spectrum of each peak in the chromatogram and the results are immediately displayed on the screen Notice that each identified peak on the display
14. 3D Plot 141 Contour Map 129 Spectra 90 Scaling a 3D Plot 141 Scaling Chromatograms 66 Scaling Spectra 90 Select 316 320 Spectra 3D View 132 Spectral Derivative 179 Spectral Formats 76 Spectral Library Confirmation 250 Spectral Math 187 Spectral Methods 28 Spectral Standard Confirmation 236 Starting IRIS 5 TotalChrom 6 Windows 5 Tab page 316 320 Tool Bars 25 TotalChrom 316 320 TotalChrom sequence 317 U User Interface 7 User Management 44 353 Iris HPLC Spectral Processing Software User Permissions 44 Would like print 316 320 V Would like 316 Would like 320 Viewing a Spectral Method 33 Viewing a Spectrum 77 Viewing Chromatograms 59 Views 9 zoom 69 Views Tree 8 Zoom Box 100 W Wavelength Maximum 225 WM 318 354
15. All absorbance values between the value at the top level and the new bottom level will be assigned to the remaining fourteen contours How do I use the Box Zoom on the Contour Map It is possible to zoom into a visually defined wavelength and or time region on the contour map using the box zoom To zoom into a visually defined wavelength and or time region 1 Move the mouse cursor inside the plot region and position it at a corner of the area you want to zoom 2 Hold down the left mouse button and drag the mouse to form a box around the area to be zoomed 3 Release the mouse button The region you wish to zoom into will be outlined with a box containing eight control points The box can be resized by clicking and dragging on any of the control points 4 Move the mouse pointer into the zoom region and click the left mouse button The zoomed area now fills the trace display region 5 You can abort the zoom before step 4 by clicking the left mouse button outside the zoom box 6 To return to a view of the entire trace select Actions gt Autoscale gt X and Y How do I use the Autoscale tools on the Contour Map Both the Autoscale Y and Autoscale X and Y commands are useful tools in scaling the Contour Map To autoscale the absorbance without changing the wavelength or time axes Use this command to scale the absorbance range after a zoom on the wavelength and or time axis 1 Click anywhere on the map 2 Click
16. Magnum W aveiengh Momem Warelengh 199 ni Benzene 0p L eary Match nD 2d Spectral Derivative Spec ad Math Peak Auty F sorbance Ratio Wovelength Marre Spectral Randed c V Famire Conect Specta Spectra Lirary Co Peak ifs ary Search f trsy Lint Retertion Troe Ads Extract Cromatogy Apex Optimized Or Custom Views i He Dutance Theihoks TA t Component y f berne Toine Ethyl Berwene Propyt Benzene Iut Benzene hat Eres Data qxhergile Kertfied t f Y a Disglay Aper O Spectrum Rasetine Re ne eS cs es rs eect tcl 2 an on g lt 5 od lio 285 Iris HPLC Spectral Processing Software How do modify the parameters that are used in the spectral matching The Parameters pane displays the values that are currently used in the spectral matching At any time you can modify the parameters that are listed on the on the Retention Time Adjustment page and IRIS automatically updates the display with the new library matches Below is a list of the parameters you can modify Minimum Use the Minimum Wavelength spin box to set the lower limit of the Wavelength spectrum range to be used in the spectral matching Maximum Use the Maximum Wavelength spin box to set the upper limit of the Wavelength spectrum range to be used in the spectral matching Hit distance Use the Hit Distance Threshold spin box to specify the Hit Quality threshold above which two spectra will not be con
17. Osta erangi 2 dertfind byt wth cosit a j Note The Spectrum panes remain blank until a spectrum is selected for the pane and the Result pane is blank until both spectrums have been selected 189 Iris 190 HPLC Spectral Processing Software Spectrum A Pane This pane displays the spectrum you selected on the Data Tree as Spectrum A for mathematical operations performed on this view If you do not have a spectrum already selected on the Data Tree when you first access the Spectral Math opeartion the Spectrum A Pane appears blank To display a spectrum in this pane you must click on the Spectrum A Pane and then select a spectrum that is listed on the Data Tree On the other hand if a spectrum is already selected on the Data Tree before you access this page the selected spectrum is automatically displayed in this pane If the spectrum currently displayed on this pane is not the spectrum you wish to use as Spectrum A simply click on an area inside the whitespace of the pane and then select a different spectrum from the Data Tree The new spectrum is now displayed on the Spectrum A Pane Ca a iv 4 D gargle 2 idandfiod but wth coeiton 7 333 Spectrum Chapter 7 Performing Operations on Spectra Spectrum B Pane This pane displays the spectrum you selected on the Data Tree as Spectrum B for mathematical operations performed on this view When you first access the Spectral Math opera
18. Spectral Ubrary Contieme Pesk Ubrary Search Retention Time Adtustrne Extract Qromatog ane Display agga 252 Chapter 8 Performing Operations on Chromatograms Data Tree The Data Tree displays a list of currently loaded chromatograms You use the Data Tree to select the chromatograms that you want to use in the operation The chromatogram you select from the Data Tree is displayed in the upper pane Chromatogram pane for this operation Dirplay Apes C Spectrum Baseline 2 m 253 Iris HPLC Spectral Processing Software e Chromatogram Pane This pane displays the chromatogram that you selected from the Data Tree Named peaks in the displayed chromatogram are labelled with their Component Name the Hit Quality Value and either a P or an F to indicate a Pass or Fail status which is dependent on the current value of the Hit Distance Threshold Display yoctrum 8 as etree oso8 254 Chapter 8 Performing Operations on Chromatograms Parameters Pane This pane is where you set and investigate the various parameters used to perform the Spectral Library Confirmation operation Whenever you change a parameter displayed on this operation and have a chromatogram selected on the Data Tree IRIS automatically updates the Display List and Results pane with the modified results Display Apes C Spectrum Baseline oO 255 Iris HPLC Spectral Processing Software Hit Details The
19. calculation Maximum Wavelength Lets you set the upper limit of the spectrum range to be included in the calculation Baseline Corrected Check this option to use baseline corrected spectra for the spectral math Note Checking this option affects the results of the operation however this option does not change the sample spectrum displayed in the top pane To baseline correct the sample spectrum displayed in the top pane select View gt Baseline Corrected Spectra 194 Auto A Select this option to have IRIS automatically calculate the minimum absorbance value that can be used in the calculation for Spectrum A If the value at a specific wavelength falls below this threshold the calculated result for that wavelength will be set to 0 Auto B Select this option to have IRIS automatically calculate the minimum absorbance value that can be used in the calculation for Spectrum B Manual A Select this option to manually set the minimum absorbance value for Spectrum A Manual B Select this option to manually set the minimum absorbance value for Spectrum B Chapter 7 Performing Operations on Spectra Calculation Parameters This area is where you define the mathematical operation to be performed add subtract or divide as well as specify multiplication factors for Spectrum A and B and whether or not you wish to switch Spectrum A and B and their multiplication factors in the function 195 Iris HPLC S
20. displayed that states This file was collected using an earlier version of PerkinElmer s spectral software The file is opened but all data created that is related to this spectral file will indicate that the checksum was missing 15 Iris HPLC Spectral Processing Software Menu 16 Command Close Close all spectra Information gt Chromatogram Spectrum Save Results Save As Description Removes the currently selected spectra and chromatograms from the Data tree If the selection includes an extracted chromatogram or calculated spectrum that has not yet been saved a message will be displayed that states The items selected for closing include data that has not been saved Do you want to continue The command buttons are Yes and No Removes all spectra from the Data tree If this includes calculated spectra that have not yet been saved a message will be displayed that prompts you whether or not you wish to close the spectra without saving the calculated data This command allows you to view information about a specific chromatogram or a spectrum without actually opening the chromatogram s rst file or the spectrum s uv file For more information on viewing information on a chromatogram see Obtaining Information about a Chromatogram on page 63 For more information on viewing information on previously stored individual spectrum file see Obtaining Information ona Stored Spectrum on p
21. gt Add All to View A dialogue box is be displayed with the message The data was added successfully On re displaying the Main View or Chrom Spectra View the added spectra will apear in the Data Tree 248 Chapter 8 Performing Operations on Chromatograms To save the results and parameters used in the calculation 1 Select File gt Save Results A save dialog appears that asks you to confirm whether or not you want to save the new values to the chromatogram s result file RST and save the parameters that were used calculate the results to the associated spectral method file TSM 2 Click Yes to save the results and calculation parameters Spectral Standard Confirmation values added to the result file To display the Spectral Standard Confirmation results in the Main View or Chrom Spectra View 1 Select Actions gt Label Chromatograms 2 Select Spectral Standard Confirmation from the list of available labels To review for any chromatogram previously calculated Absorbance Ratio values and the parameters used gt Select this chromatogram again on the Spectral Standard Confirmation operation The saved results and the calculation parameters are automatically displayed 249 Iris HPLC Spectral Processing Software Spectral Library Confirmation The Spectral Library Confirmation operation allows you to verify the identity of named peaks in a sample chromatogram by automatically comparing the apex spectr
22. of the current cursor position using the Offset Normalize command Ki Following is an overview of the scaling options that are available to you when you are working with a Chromatogram pane How do I visually specify an area of the display to zoom into using the Box Zoom function To zoom into a visually defined region 66 1 Move the mouse cursor inside the plot region and position it at a corner of the area you want to zoom Hold down the left mouse button and drag the mouse to form a box around the area to be zoomed Release the mouse button The region you wish to zoom into will be outlined with a box containing eight control points The box can be resized by clicking and dragging on any of the control points Move the mouse pointer into the zoom region and click the left mouse button The zoomed area now fills the trace display region You can abort the zoom before step 4 by clicking the left mouse button outside the zoom box To return to a view of the entire trace select Actions gt Autoscale gt X and Y Chapter 3 Opening and Viewing Chromatograms How do view and change the axis range for a particular chromatogram 1 You can view and change the axis range for particular chromatogram by right mouse clicking on a chromatogram and selecting Format Graphs from the context menu that appears The Format Graphs window appears with the Chromatogram tab selected This window allows you to set the minimum and
23. select the spectrum you wish to save From the File menu select Save As The Save Spectrum As dialog appears Specify a filename and location for the spectral file Chapter 7 Performing Operations on Spectra Spectral Math The Spectral Math operation is where you perform mathematical operations add subtract and divide on spectra and view the results From this operation you select two spectrums that you wish to add subtract or divide as well as specify the wavelength range of the operation and the Absorbance Threshold if necessary The results of the calculation are displayed in the lower portion of this screen and can be added to the Data Tree using the Add to View command Tell me about the Spectral Math operation File Edit View Actions Tools Help IEERO alal2 Mal 2 falala mer ol IZ maese O A Spectral Math Sample B Spectral Math identified but with coelution 7 333 example 2 Compare s 175 Operations 15 Minimum Wavelength Library Match 1 26 fo s Spectral Derivative 1 x Spectral Math gue Peak Purity os Maximum Wavelength 0 25 Absorbance Ratio o 400 Wavelength Maximum LE Sn a ed fn LF a PF UE 225 250 275 at Baseline Corrected Thresholds example 2 identified but with coelution 7 341 Autoa C Manual A z AutoB Manual B RETF SUE E Fa 2 FT eco UP E 200 225 250 275 300 325 350 375 Spectral Standard Confirmatio
24. the printing details are stored in an IRIS Process Spectral Method Therefore before you can use AutoCalc to automatically print the apex spectra display for each sample in a sequence you must first update the IRIS Process Spectral Method that has the same name as the TotalChrom Method that will be used to process the sequence with certain details of that output including what printer should be used To update an IRIS Process Spectral Method that will be used by AutoCalc for automated printing of apex spectra in TotalChrom 1 In IRIS open a chromatogram that has been processed with the same TotalChrom method that will be used to run or reprocess the sequence 2 Next verify the name of the chromatogram s associated TotalChrom method To do this first right mouse click on the chromatogram in the IRIS Data Tree and select Information from the context menu that appears A Chromatogram Information dialog appears that shows the TotalChrom method associated with the selected chromatogram Make sure that this method name is the same name as the TotalChrom method that will be used to process the sequence 3 Now exit the Chromatogram Information dialog box 4 Make sure that the chromatogram that you just selected in step 2 is still selected highlighted in blue on the Data Tree 5 From the IRIS menu bar select File gt AutoCalc Print Setup The AutoCalc Print Setup dialog appears 320 Chapter 9 AutoCalc Automating Arithmet
25. you can modify any of these parameters by doing the following e First exit the Method Viewer dialog box e Then for the chromatogram opened in Step 1 select any of the desired operations that are listed under Operations in the IRIS Views tree e Make any required changes to the parameters listed for the operation you selected e Select the next operation to which you want to make changes When you select a different operation a dialog appears that prompts you to select if you want to save the changes From this dialog select the desired save mode and click Yes e After completing the changes for the last operation save the results via File gt Save Results The Process Spectral Method is then updated with all the modified parameter values Moreover for AutoCalc these parameters can now be used by any chromatograms processed by the TC Method having the same name Note For information on using AutoCalc to print automatically the Apex Spectra display for each sample in a running sequence see the section titled Using AutoCalc to print automatically the Apex Spectra display for each sample in a running sequence on page 320 316 Chapter 9 AutoCalc Automating Arithmetic Operations Extractions and Apex Spectra Printing How do I use AutoCalc to automatically perform the desired operations during a TotalChrom sequence In general you specify which arithmetic operations chromatographic extractions and or apex spectra pr
26. you will not see the extracted spectrum on the Data Tree until you exit the Spectra 3D View The reason for this is because on the Spectra 3D View the Data Tree is used only for selecting the chromatogram that you want displayed You will be able to see all of the spectra you have extracted once you select a different View such as the Main View or the Chrom Spectra View What Views should I use to capture spectra Although you can use the Main View to capture spectra from a chromatogram that is displayed on a Chromatogram pane Contour Map and or 3D Plot we recommend you use the following Views to capture spectra e f you want to capture spectra from a chromatogram use the Chrom Spectra View or the Main View If you want to capture spectra from a point on a contour map use the Contour Map View e f you want to capture spectra from a point on a 3D plot use the 3D Spectra View Note Unlike the Main View where extracted spectra are displayed on the Data Tree when you extract a spectrum from the Contour Map View or 3D Spectra View you will not see the extracted spectrum on the Data Tree until you exit the Contour Map View or 3D Spectra View The reason for this is because while you are viewing the Contour Map View or 3D Spectra View the Data Tree is used only for selecting the chromatogram that you want displayed on the View You will be able to see all of the spectra you have extracted once you select a different View such as the
27. 181 Iris HPLC Spectral Processing Software 182 Spectrum Pane This pane displays the original sample spectrum that you have selected from the Data Tree Ss Iris Ail a E3 Fie Edt Vew Actions Took help PEENI EA S aad 9 SM sa Sh He a LESIE w oc hs 01 Bas Wa aie Ler AA E Eg Derivative Result seora Dervatrve Spectra30 A Compare Mimun Wavelength Operations 200 D Livery Match Spectral Derivative Spectral Math Maimam Wavelengh Peak Purity 400 Absorbance Ratio Wavelength Maximum Basekne Conected Spectral Rardard Confirmation wy lt gt Data exatele 3 Gectiied butyl benzene 4 26 Re lt etl S17 Display z Sample Spectrum B First Derivative m fd Second Dorivatve phe eee oe ee oe E Thed Dosivative lt gt 5 330 305 EF outh Denvative Lognamansger amp Chapter 7 Performing Operations on Spectra Parameters Pane This pane allows you to set the minimum and maximum wavelengths used for calculating spectral derivatives as well as select whether or not you wish to use the baseline corrected spectrum for the derivative Sample Spectrum E First Derivative F outth Denvative 183 Iris HPLC Spectral Processing Software e Display List You use the Display List to select which spectra you want to see on the Derivatives Pane Items that appear checked are displayed on the Derivates Pane while unchecked
28. 3D Plot pane To extract and display a spectrum from a point on the Contour Map 1 On the Main View check the chromatogram on the Data Tree that you want displayed as the 3D Plot The chromatogram is displayed on the Chromatogram pane Contour Map pane and 3D Plot pane 2 Float your mouse pointer over a point on the 3D Plot to temporarily view in the Spectra pane the spectrum from that point As you continue to float your mouse pointer over the 3D Plot the Spectra pane automatically updates so that the spectrum from the current location of your mouse pointer is displayed in the appropriate pane 3 If you see a spectrum that you want extract just double click on that area in the 3D Plot and the spectrum at the wavelength and time you clicked appears in the Spectra pane Note Unlike the Main View where extracted spectra are displayed on the Data Tree when you extract a spectrum from the Spectra 3D View the spectrum is added to the Data Tree however you will not see the extracted spectrum on the Data Tree until you exit the Spectra 3D View The reason for this is because on the Spectra 3D View the Data Tree is used only for selecting the chromatogram that you want displayed You will be able to see all of the spectra you have extracted once you select a different View such as the Main View or the Chrom Spectra View 116 Chapter 5 Viewing the Data How do I temporarily capture a chromatogram from the Spectra pane On
29. 90 Chapter 4 Viewing Spectra Normalizing Spectra The Normalization commands are most useful when multiple overlaid spectra are displayed The Normalization commands are as follows Note If you are trying to scale a single chromatogram or spectrum only Offset Normalize and Point Normalize are useful commands e The Normalize X and Y command is useful when multiple overlaid spectra are displayed This command scales the maximum Y value in the active window to 90 for each spectrum and sets the X axis scale so that the entire largest spectrum is displayed e The Normalize Y Only command m works like Normalize All except it rescales only the Y axis e The Offset Normalize command is useful when multiple overlaid spectra are displayed or when a single spectrum is displayed This command scales the data point with the maximum Y value to the right of the current cursor position to 90 in the region for each spectrum e The Normalize Point command is useful when multiple overlaid spectra are displayed or when a single spectrum is displayed This command scales the Y value at the current cursor point to 90 The new 90 scaling is applied to every spectrum 91 Iris HPLC Spectral Processing Software Detailed Descriptions of Normalize Buttons Normalize All The Normalize X and Y command applies to chromatogram displays as well as to spectral displays containing multiple overlaid spectra This command scales the maxim
30. Chromatogram operation In the Extract Chromatogram operation you specify the wavelength at which to extract the chromatogram from the spectral file The same wavelength is used for the complete chromatogram In the Apex Optimized Chromatogram operation the wavelength used for extraction is the wavelength maximum of the chromatographic peak in the peak apex spectrum the same value as is return by the Wavelength Maximum function This is determined for each peak in the chromatogram and the extraction wavelength adjusted for each peak The final chromatogram is therefore the sum of each of these extracted sections The rules for creation of the Apex Optimized Chromatogram are 1 The wavelength used for a peak that is baseline separated from any previous peak is the wavelength maximum of the apex spectrum of that peak The peak is labelled with its detection wavelength 2 If the peak is not baseline separated from the previous peak then the wavelength of the previous peak is used Instead of the detection wavelength the peak is labeled with an to indicate that it is unresolved from the earlier peak 3 Use the View gt Chromatogram Baselines to see how TotalChrom has treated each peak 299 Iris HPLC Spectral Processing Software Tell me about the Apex Optimized Chromatogram operation The Apex Optimized Chromatogram operation is comprised of the following areas e Views Tree The Views Tree provides you access to the Apex Optim
31. In order to use this page you must first select a chromatogram that is listed on the Data Tree The selected chromatogram is displayed on the page in the upper graph Chromatogram pane and each peak in the chromatogram is labeled with the Absorbance Ratio value As noted in the previous section the Absorbance Ratio of a compound is defined as the ratio of the absorbance at two specified wavelengths in its peak apex spectrum The value is independent of concentration characteristic for the compound but not necessarily unique IRIS calculates the absorbance ratio values using the parameters that are currently displayed on the page At any time you can recalculate the absorbance ratio values by modifying the two wavelength values used in the calculation specifying a different absorbance threshold as well as by selecting whether or not baseline corrected spectra are used in the calculation IRIS automatically updates the Absorbance Ratio page to display the recalculated results If you are interested in the absorbance ratio for a specific peak click on the peak and in the bottom graph Results pane IRIS displays the apex and baseline spectra for the peak as well as the Absorbance Ratio value The apex spectra are annotated with the positions of the two wavelengths used and the absorbances at each wavelength Note Use the Display List to specify what is displayed on the Results pane Items that appear checked on the Display List are plotted on th
32. LALLI IN EE 200 225 250 275 300 325 350 375 400 4 Login manager By Figure 3 1 Main View after opening a chromatogram 3 Repeat steps 1 and 2 for each additional chromatogram you want to open Note In order for you to easily identify the newly opened chromatogram please note that the chromatogram graph is color coded to match the chromatogram name listed on the Data Tree 56 Chapter 3 Opening and Viewing Chromatograms What happens when I open a chromatogram in IRIS When you open a chromatogram IRIS automatically determines and specifies on the chromatogram the times at which the baseline upslope apex and down slope spectra occur e The upslope and down slope spectrum positions times are determined as a percentage of the peak height e By default the TotalChrom peak start position time is used as the origin of the baseline spectrum however you can change how spectra are baseline corrected within a chromatogram from the Spectral Baseline Correction dialog On this dialog you can select from three options to select calculate the baseline spectrum For more information on the defining how you are going to perform the baseline correction of the spectra refer to 103 e The TotalChrom peak retention time is used as the origin of the apex spectrum 57 Iris HPLC Spectral Processing Software What happens when I open multiple chromatograms Each time you open a new chromatogram the following occurs The
33. Main View or the Chrom Spectra View 82 Chapter 4 Viewing Spectra How do I use the Range Box to extract spectra Note The Range command is enabled only on Views not Operations when the View contains a Chromatogram pane with a single chromatogram displayed This command is also available from the context menu for a stacked chromatogram This Range command n located on the tool bar is used to display all the spectra within a given time range When the Range icon is selected a green range box is displayed on the chromatogram To activate the range box simply position your mouse pointer in the range box and click File Edit view Actions Tools Help sieia olalal2 mal fefeaie w e Of e OF haee 1 fla el Main View Chromatograms Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views 05 11 5 22 5 33 5 44555566 577 58859 Ta example 1 identified and well sep 0 s SLSLSTELEAI ELSAN LELEI LELES ELSIS LALLE LELEN ET raga 200 225 250 275 300 325 350 375 a09 i Login manager By Figure 4 2 Click on the Range icon to activate the range box 83 Iris HPLC Spectral Processing Software When the range box is activated This command is used to display all the spectra within a given time range When this command is selected a green range box is displayed on the chromatogram e Positioning the mouse pointer in the range
34. Minimum Wavelength and or Maximum Wavelength The Spectral Standard Confirmation value labels are updated for every peak in the chromatogram To examine the effect of using baseline corrected spectra on the Spectral Standard Confirmation values gt Check Baseline Correct Spectra The Spectral Standard Confirmation value labels are updated for every peak in the chromatogram To change the minimum absorbance values that are used in the operation 1 Select the Manual radio button under Threshold for Sample The Minimum Absorbance spin box is enabled 2 Use the spin box to specify a new minimum absorbance value The Spectral Standard Confirmation value labels are updated for every peak in the chromatogram 3 Select the Manual radio button under Threshold for Standard The Minimum Absorbance spin box is enabled 4 Use the spin box to specify a new minimum absorbance value The Spectral Standard Confirmation value labels are updated for every peak in the chromatogram To return to automatically calculating the minimum absorbance value gt Select the Auto radio button under Threshold for Sample and or Threshold for Standard if you want to have IRIS automatically calculate the minimum absorbance value that can be used in the calculation The Spectral Standard confirmation value labels are updated for every peak in the chromatogram To add the displayed spectra in the results pane to the Data Tree gt Select Actions
35. Normalize Point The Normalize Point command applies to chromatograms contour maps and spectra For chromatograms and spectra this command scales the Y value at the current cursor point for every chromatogram or spectrum to 90 Note The Normalize Point button is valuable in the Contour Map view as discussed in the section titled Scaling a Contour Map on page 129 The figure below shows detail from spectra extracted at different points on an Anthracene peak To amplify any possible differences we can use the Normalize Point command to force all the curves to an identical absorbance at a specific point on the peak File Edit View Actions Tools Help bian on alem nala elsjareie mra oF el Main View Chrom Spectra Contour Map Spectra3D Compare amp Operations Custom Views Asan 1 identified and well a 473 o ae a Ta Ta aT aT TS TTT 315 320 325 330 335 340 345 350 355 360 365 370 375 36 380 385 390 395 od Login manager amp Figure 4 11 Spectra Detail 98 Chapter 4 Viewing Spectra OER Eile Edit View Actions Tools Help sielalelalsl2inialz e falnis el4 ose o ee Sh B al Ua ieee ZI ex Chrom Spectra View Spectra Main view Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views ELETE E LOLS ULL LL IUTL LEU LOLS LLI E A TELS ARELA EUG EULER EUS LARL TELAN N LI E a OEL E GLI I GALE L CURL SL ELT
36. This list box shows all the spectra currently listed in the library alphabetically by component name You can select a spectrum from this list to view a graphical display of the spectrum in the pane directly below the Current Spectra and Library list boxes e You can view additional information about a component by right mouse clicking on a Library spectrum and selecting Properties from the context menu that appears A dialog appears that shows the source the chromatogram and retention the baseline and who added the spectrum and when This check box allows you to select whether or not the spectra displayed on this dialog have been baseline corrected Note This checkbox only determines what is displayed on the Edit Library dialog it does not determine whether or not baseline corrected spectra are used in library operations This checkbox allows you to select whether or not the baseline spectrum is also displayed on the graph This command button displays the audit trail for the current library Chapter 6 Spectral Libraries How do I access the Edit Library dialog To access the Edit Library dialog 1 From the Tools menu select Build Library gt Edit The Open Library dialog appears Open Library Look in O Iris A Ba ions views Recent data DB Library Desktop My Documents My Computer My Network File name Places Files of type Iris Library File alb 2 Select the Library you wish to
37. Tree displays a list of currently loaded chromatograms You use the Data Tree to select the chromatograms that you want to use in the operation The chromatogram you select from the Data Tree is displayed in the upper pane Chromatogram pane for this operation Onplay B Apes O Baseline 5 Chapter 8 Performing Operations on Chromatograms Chromatogram Pane This pane displays the chromatogram that you selected from the Data Tree Maxim amntoy Spectral Derivative Spectra Math Post Arty Aoerbarce Ratio Wavelength Masten Spectral Standard Convey Spectral Ltvary Corfirme Pot Lfeary Search Reterhon Tene Adastne Extract Clhomatogans Wavelength Mmari Moeam W avelergh fz30 Manm Wavelength rey 2 JF Baseine Conect Specta Absorbance Threshold Ayo Maua LELETET 229 Iris HPLC Spectral Processing Software Parameters Pane This pane is where you set and investigate the various parameters used to determine the Wavelength Maximum values Whenever you change a parameter displayed on this operation and have a chromatogram selected on the Data Tree IRIS automatically updates the Display List and Results pane with the modified results 230 Chapter 8 Performing Operations on Chromatograms e Display List You use the Display List to select the information you want displayed on the Results pane When items appear checked on this list they are displayed in the Results Pane Meanwhile un
38. again on the Absorbance Ratio operation The saved results and the calculation parameters are automatically displayed 224 Chapter 8 Performing Operations on Chromatograms Wavelength Maximum The Wavelength Maximum operation is used to determine the wavelength maximum of the apex spectrum of each peak in a chromatogram The Wavelength Maximum of a spectrum is defined as the wavelength of the highest absorbance peak in the spectrum above a specifiable minimum wavelength gt To access this operation expand the Operations node on the Views tree and select Wavelength Maximum File Edit View Actions Tools Help lasanan 3 ke fealesyen welo e E Wavelength Maximum amp Operations Library Match Minimum Wavelength Spectral Derivative Lz i 2 Spectral Math z Peak Purity Absorbance Ratio Maximum Wavelength Wavelength Maximum 400 Spectral Standard Confir Spectral Library Confirme Baseline Correct Spectra Peak Library Search Retention Time Adjustme Absorbance Threshold Extract Chromatograms v Auto C Manual DO DOO CC OO CC AA 22 33 44 65 66 irs 88 separated001 WMax 244 M Apex O Baseline hain S E EE E EE LN TR EE OE E URS E SES EE Wavelength Maximum 220 275 330 385 Login manager amp Figure 8 3 The Wavelength Maximum operation 225 Iris HPLC Spectral Processing Software Determining the wavelength maximum of chromatographic peaks In order to use this page you must
39. appears selected and the border of the pane turns blue C 220 275 330 385 If a Stacked display is being used on the Chromatogram pane and an Overlaid display is being used on the Spectra pane you can float the cursor over a point on the Chromatogram pane and have the associated spectrum displayed When the mouse pointer is moved close to any edge of the plot region it changes into a four headed arrow fag aan A drag operation when the mouse pointer is in this form drags the graph around the plot region You can also scale spectra with a large selection of tools For more information on scaling spectra see the section titled Visually Comparing Spectra on page 89 79 Iris HPLC Spectral Processing Software Tell me about the context menu that appears when I right click on a Spectra Pane When you right click on the Spectra Pane a context menu appears that contains the following commands Command Print Pane v Baseline Spectra Stack Spectra Overlay Spectra Cursor Hide Pane Format Graphs 80 Description Prints just the current pane Adds the baseline spectrum for the selected spectrum to the Data Tree and displays the baseline spectrum on the Spectra pane The baseline spectrum is identified by the retention time of the spectrum or if a range of spectra are being used the start and end times of the range followed by the word base This command toggles between Stack S
40. appears that prompts you to select whether or not you wish to permanently exclude the selected spectrum 3 Click Yes to permanently exclude the spectrum The spectrum still appears in the Library List however if you click on the spectrum the Add Exclude and Replace buttons are disabled and the Spectrum Display shows that the selected spectrum is excluded 166 Chapter 6 Spectral Libraries How do I replace a spectrum in the Library List with one of the Current Spectra The Replace command button deletes the spectrum you have selected from the Library list box and replaces it with the spectrum you select from the Current spectra list box To replace a Library spectrum with a spectrum listed in the Current Spectra list box 1 Click on the spectrum in the Library list box that you wish to delete 2 Click on a replacement spectrum in the Current Spectra list box The Replace button is enabled 3 Click Replace A dialog appears that informs you that the spectrum selected on the Library list box will be replaced with the spectrum selected on the Current Spectra list box 4 Click Yes The Library spectrum is replaced with the spectrum selected on the Current Spectra list box 167 Iris HPLC Spectral Processing Software Identifying a Spectrum using Library Match You use the Library Match operation to match a selected spectrum against the spectra in a list of libraries The results of this match allow you to identif
41. are reported as 888 Wavelength Maximum and Absorbance Ratio e Peaks for which the Wavelength Maximum and Absorbance Ratio values can be calculated are reported with the same value as in IRIS e Peaks which are already identified in TotalChrom and for which the Wavelength Maximum and Absorbance Ratio values cannot be calculated are reported in TotalChrom as 888 e Peaks which are not already identified in TotalChrom and for which the Wavelength Maximum and Absorbance Ratio values cannot be calculated are not identified and are not reported in TotalChrom 310 Chapter 8 Performing Operations on Chromatograms Spectral Library Confirmation e Pass results are reported as the normal Hit value e Failed results are reported as a negative Hit value e Named peaks in the sample for which no match can be found in the library are reported as 999 Peak Library Search e The component name found by IRIS will be entered as the Component Name in the Component List The Hit value will reported This test has no failure results Peaks that are not matched in the library are not recorded in TotalChrom Note Carefully Saving the results of this test to TotalChrom will delete any existing Component List These results should only be saved if a component list does not already exist for if you want to completely rewrite the component list Any information either from TotalChrom or IRIS stored in an existing component list will be lost Extract Ch
42. are returned to the Retention Time Adjustment operation At this point the listed components in the chromatogram s embedded method are checked against all the components listed in the selected spectral libraries For this operation these components can lie well outside of the TotalChrom method s peak tolerance window and can even have been initially mis identified in the result file For each component name that is matched the library spectrum is then matched to the closest fitting peak apex spectrum in the chromatogram If this spectral match falls within the selected threshold value peak identification is confirmed Thereupon the chromatogram is graphically displayed with the properly matched identified components and includes the annotation of the adjusted retention times See example below x DEK Fie Edit View Actions Tools Help slsgelalalelmhlsf elman mlo O PESENE AA A AA Jke m 5 J 4 Retention Time Adjustment Operations k Library Match Minimum Wavelength Spectral Derivative fis es Spectral Math z Peak Purity Absorbance Ratio Maximum Wavelength Wavelength Maximum 400 Spectral Standard Confirmatior i Spectral Library Confirmation Hit Distance Threshold Peak Library Search i 0 05 Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatograr Custom Views a JV Baseline Corect Spectra S Adjusted RT ibrar List n gt 1 87 2 62 3 75
43. are used to Extract Chromatograms Each time you select a radio button on the Extract Chromatogram pane you can specify the following parameters for the chromatogram you want to extract Wavelength Enter the analytical wavelength for the extracted chromatogram in this text box The available wavelength range for this text box depends upon the range available from the original spectrum Bandwidth Enter the analytical bandwidth for the extracted chromatogram in this text box The bandwidth is the total width of the wavelengths used The Analytical or Reference Wavelength is centered in this range thus an Analytical Wavelength of 250 nm and a Bandwidth of 10nm would use data in the range of 245 255nm Note The Bandwidth cannot be set such that it would result in data stretching past either end of the current wavelength range Thus if you are working in the UV range 190 400 nm and set an analytical wavelength of 195 nm the maximum bandwidth you can set is 10 nm 5nm Setting a bandwidth too wide or too close to the end of the range for the current bandwidth will result in an error message that provides you with assistance in setting valid values Enter the reference wavelength to be used in this text box Reference A text box for entering the reference bandwidth to be used bandwidth Note To turn off the Reference Channel enter 0 as the value for Reference bandwidth A message will appear when you enter 0 that informs you that w
44. bars are displayed Enabled at all times Toggles whether or not the View tree is displayed Enabled at all times Toggles whether or not the Data Tree is displayed Enabled at all times Toggles whether or not the Parameters pane for Operations is displayed Note The Parameters pane always includes the Display or Hits list Menu Actions Command Panes gt Chromatogram Spectrum Contour Map 3D Plot View Template gt Save As Delete Export Import Zoom control gt vX axis vY axis vZ axis Autoscale gt X and Y Y only Chapter 1 Introduction Description Enabled only on Operations This command allows you to select whether or not a pane selected in the menu is displayed on the view When you hide a pane a Custom View is formed For more information on Custom Views refer to the section titled Custom View on page 150 Shown panes are checked hidden panes are unchecked Enabled for all Views This command is disabled on Operations Note Hiding a pane does NOT unload the chromatogram or extracted spectra This command only hides shows the pane The contents do not change Save As Displays the Save View As dialog Always enabled Delete Deletes the selected custom view Enabled only when a custom view is selected Export Displays a standard file selector enabling the selected custom view to be exported to disk Enabled only when a custom view is selected Import Displa
45. box then select the replacement spectrum from the Current Spectra list box and finally click the Replace button This command button allows you to add a spectrum that is currently selected on the Current Spectra list to the Library When you select a spectrum from the Current Spectra list box and click Add the Add to Library dialog box appears From this dialog box you enter the component name for the spectrum Note Make sure that you enter the component name correctly on the Add to Library dialog box before you click OK The component name cannot be edited once it has been entered into the library Exclude This command button is enabled when a spectrum that has not already been excluded is selected from the Library list box This command permanently excludes a selected spectrum so it is not used for operations When a spectrum is excluded it remains in the Library list box and you can still click on the spectrum and view a graph of the selected spectrum However when an excluded spectrum is selected the Add Exclude and Replace command buttons are disabled 163 Iris HPLC Spectral Processing Software Library Baseline corrected Show Baseline Audit Trail 164 This command button deletes the spectrum that is selected on the Library list box and replaces it with the spectrum that is currently selected in the Current Spectra list box This command is only enabled when a spectrum is selected from both lists
46. buttons located on the top of this pane there are eight radio buttons displayed on the page Specify the Analytical Wavelength Bandwidth Reference Wavelength and Reference Bandwidth for the chromatogram you wish to extract As soon as you enter a valid Analytical Wavelength the extracted chromatogram is displayed If you want to extract additional chromatograms select the next radio button and once again enter the parameters for the chromatogram IRIS will remember the parameters you specify on each radio button you selected These parameters will be displayed each time you select the corresponding radio button until you select a new chromatogram from the data tree or leave the Extract Chromatograms page You can save the extracted chromatograms by selecting File gt Save Results from the IRIS menu bar IRIS automatically creates RAW files for each extracted chromatogram These raw files are automatically reprocessed by IRIS and TotalChrom Result files RST of the same name are created The RAW files and corresponding RST files that are automatically created are named with the same name as the original result file with the following additional information appended to the file name the wavelength collected under the bandwidth the reference wavelength and the reference bandwidth 297 Iris HPLC Spectral Processing Software Apex Optimized Chromatogram The Apex Optimized Chromatogram operation allows you to create a c
47. calculate any results you have saved back to the TotalChrom Result file 30 Chapter 1 Introduction Process Spectral Method The Process Spectral Method is also created when a chromatogram is first opened in IRIS This spectral method is given the same name and stored in the same location as the TotalChrom Method that was used to create the result file that you opened in IRIS however the file extension is tsm instead of mth The screen shot below shows the Chromatogram Information dialog for the example chromatogram named example 1 identified and well separated rst This dialog shows that the chromatogram was processed by the TotalChrom method named ex1 identified mth Chromatogram Information Result File c lris data data datadatalexample 1 identified and well separatec Number of Peaks 3 Raw File c Wris data data dataidataiExamplel _well_separated001 ray Spectral File clris data dataldataidata Example1 _well_separated001 spe User User name unavailable Date 01 04 2006 Time 08 49 10 Number of Spectra 1290 c lris dataldata datadatalex1 identified mth Figure 1 7 The Chromatogram Information dialog can be accessed by right mouse clicking on a Chromatogram in the IRIS Data Tree and selecting nformation from the context menu that appears 31 Iris HPLC Spectral Processing Software Now that we know the TotalChrom method used to process the chromatogram we can use the File gt Open Method command
48. command we were able to confirm the expectation that the four spectra were not identical 96 Chapter 4 Viewing Spectra Offset Normalize A The Offset Normalize command applies to chromatogram displays as well as to spectral displays containing multiple overlaid spectra This command scales the data point with the maximum Y value to the right of the current cursor position to 90 in the region for each spectrum In the Figure 4 7 when examining a set of spectra to observe their differences we expanded the scale to observe only the wavelength range of interest and then we used the Normalize Y command Since there was no higher absorbance to the right of the region of interest we could have more easily achieved our goal by using the Offset Normalize command as shown in the figure below In this case we positioned the cursor at approximately 230 nm and then selected Offset Normalize us File Edit View Actions Tools Help slslalolalsienalF wafers mekle e Se Mal 3h Wie Wal veal vale lerfig AA ei J Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views Propyl Benzene M example 1 identified and well sep 1 665 2 537 3 637 5 111 Simtel a a a ee ee ol el al 200 4229 62 250 275 300 325 350 375 40g Login manager amp Figure 4 10 Using Offset Normalize 97 Iris HPLC Spectral Processing Software
49. dialog allows you to view information about a selected library such as the compounds in the library and their spectra How do I access the View Library dialog To access the view Library dialog 1 From the Tools menu select View Library The Open Library dialog appears Open Library Look in O iris D Icons views Recent pata Library Desktop My Documents My Computer File name Files of type Iris Library File alb 2 Select the Library you wish to view and click Open The View Library dialog appears View Library example library alb Description Minimum Wavelength Maximum Wavelength 235 Spectra Toluene Ethyl Benzene Propyl Benzene Benzene USER Fo a a CL tt A ad a eet Poe et od td ce a ee R E eC M Show baseline corrected spectrum I Show baseline spectrum Audit Trail 2 160 Chapter 6 Spectral Libraries Tell me about the View Library dialog The View Library dialog displays the following information Name The name of the library file you opened appears here Description A description of the library appears here Note You can specify a description for the library when you are editing creating a library and the Edit Library dialog is displayed For more information on entering a description for the library see Editing a Library on page 162 Minimum The library s minimum wavelength value appears here Wavelength Max
50. display the newly opened chromatogram or spectrum Spectra that you have extracted from a chromatogram are listed in ascending order on the Data Tree under the parent chromatogram For information on extracting spectra see page 78 11 Iris HPLC Spectral Processing Software The Data Tree Context Menu A right click on a chromatogram or spectrum in the Data tree displays the context menu that contains a list of commands you can select The table shown below lists all of the context menu commands Please note that certain menu commands are enabled or disabled depending upon whether you have a chromatogram or spectrum selected Note The command selected only applies to the item right clicked on Displays the relevant information for the item right clicked on Displays the Audit Trail dialog for the item right clicked on Close Save Results x Match color v Baseline Spectra Spectral baseline correction 12 Deletes the chromatogram or spectrum right clicked on from the Data tree Closing the chromatogram will remove the Chromatogram from the data tree and close all its associated files such as Contour Map and 3D Plot Closing the chromatogram will close all its associated spectra This command allows you to save the results and the parameters used in an operation performed on a chromatogram Refer to the section titled Saving the Results of a Calculation on page Error Bookmark not defined for more information
51. double click on the Contour Map at the wavelength of the chromatogram you want to see The chromatogram and spectrum at the wavelength and time you clicked are displayed in their respective panes Please note that chromatograms are only temporarily displayed and will be cleared when you change the view On the other hand the spectra that are displayed on the view are extracted and therefore added to the Data Tree However you wont see the extracted spectra listed on the Data Tree until you select another view such as the Main View or Chrom Spectra View 128 Chapter 5 Viewing the Data Scaling a Contour Map The most useful scaling commands for a Contour Map view are the Normalize Point and Zero commands Both commands adjust the scale based on the current position of the cross hair cursor However you are not limited to using the Normalize Point and Zero commands to scale a Contour Map In fact you can scale a Contour Map performing any one of the following options e Use the Normalize and Zero commands to set the absorbance range covered by the map e Zoom into a visually defined wavelength and or time region on the contour map using the Box Zoom e Use the Autoscale commands to return the map to its default scaling e Scale all three axes on the Contour Map page by specifying Limits on the Format Graphs dialog How do scale the Contour Map using the Normalize Point and Zero commands As stated earlier probably the two
52. gt Normalize gt Point from the menu bar The chromatogram is normalized at the cursor position 71 Iris HPLC Spectral Processing Software How do I close a chromatogram gt You can close a chromatogram by selecting the chromatogram from the Data Tree and then selecting File gt Close When you close a chromatogram the chromatogram is removed from the Data Tree and all of the chromatogram s associated displays such as the Contour Map and 3D Plot are no longer shown In addition all of the chromatogram s associated spectra are removed from the Data Tree and are no longer displayed Note Ifyou do not want to remove a chromatogram from the Data Tree you can hide it from being displayed by unchecking the chromatogram on the Data Tree when you are looking at the Main View Chrom Spectra View and Compare View On all other Views you can hide the chromatogram from being displayed by simply selecting a different chromatogram on the Data Tree 72 Chapter 3 Opening and Viewing Chromatograms Initializing a TotalChrom Environment with an IRIS Chromatogram This topic shows you how to pass a chromatogram that is open in IRIS back to TotalChrom It is possible to move a chromatogram you are viewing in IRIS to one of two TotalChrom environments Reprocess or Graphic Method Edit gt Right mouse click on the chromatogram in the Data Tree and select TotalChrom gt Reprocess or Graphic Method Edit from the context menu that ap
53. it is a fairly relative measure What is more useful in many cases is to look at the whole hit list for compounds with similar chemical makeup to elucidate the class of the unknown compound 351 3D Plot Scaling 141 A About IRIS 3 Absorbance Ratio 214 Add Apexes 153 Add Apexes 154 All 318 Allows 316 320 Always enabled 316 320 annotation 325 Apex Optimized Chromatogram 298 apex specta 320 Apex Spectra 316 320 AR 318 Audit Trails 45 Autocalc 316 320 AutoCalc 314 Autocalc Print define 316 320 Autocalc Print 316 Autocalc Print 320 AutoCalc Print dialog 316 320 Autocalc Print Setup 316 320 AutoCalc Print Setup 320 Autoscale 68 Autoscaling 90 B Baseline Correction of the Spectra 103 Box Zoom 66 Build Library 157 Index C Calculation Algorithms 350 Chrom Spectra View 121 Chromatogram 63 Chromatogram s Spectral Method 30 Chromatographic Spectra 76 close a chromatogram 72 Compare View 144 Comparing Spectra 89 Contour Map Scaling 129 Contour Map View 122 Copy Object 326 Copying IRIS Images 326 Custom Views 150 D Data Tree 10 Data Tree 316 Data Tree 320 Default Method 29 Define AutoCalc Print 316 320 Define 316 Define 320 E EC 318 Editing a Library 162 Editing the Default Method 39 Electronic Signatures 53 Enhanced Security 43 Euclidean Distance Algorithm 351 Extract Chromatograms 290 F Features 4 Format Graphs 67
54. modify the parameters that are used to create a chromatogram with the optimum wavelength set for each peak The Parameters pane is where you set and investigate the various parameters for creating a chromatogram with the optimum wavelength set for each peak At any time you can optimize adjust the parameters that are listed on the Apex Optimized Chromatogram operation and the Apex Optimized Chromatogram value labels are updated for every peak in the chromatogram Below is a list of the parameters you can modify Minimum Wavelength Enter the Minimum Wavelength to set the lower limit of the spectrum range to be used for the calculation of the wavelength maximum Maximum Enter the Maximum Wavelength to set upper limit of the spectrum Wavelength range to be used in the calculation of the wavelength maximum Maximum analytical Enter the maximum analytical bandwidth that will be used to bandwidth create the optimized chromatogram If the analytical wavelength falls too close to either end of the range the full range may not be available Reference Enter the Reference Wavelength to be used in creating the wavelength optimized chromatogram Reference bandwidth Enter the Reference Bandwidth to be used in creating the optimized chromatogram Note If you set this field to 0 then the Reference Channel is turned off Baseline corrected Check this option to use the baseline corrected spectrum for the calculation of the wavelength maxi
55. most useful scaling commands on the contour map are the Normalize Point and Zero commands in the Tool bar On a Contour Map the Normalize Point command adjusts the scale so that the absorbance at the cursor position is represented by the top color in the scale If the absorbance at the cursor position was originally less than the highest absorbance this has the effect of stretching the scale and revealing more detail in the map The Zero command does the opposite action and assigns a specified absorbance to the bottom contour All data below this level is displayed in the bottom color blue and thus is hidden By combining the use of the two commands you can set any absorbance range on the map to examine specific areas of interest To assign an absorbance to the top contour 1 Click in the map at the point to be assigned to the top contour 2 Click on the Normalize Pointl icon All absorbance values equal to or above the absorbance at this point will be assigned to the top contour white All absorbance values between the value at the zero level and the new top level will be assigned to the remaining fourteen contours 129 Iris HPLC Spectral Processing Software To assign an absorbance to the bottom contour 1 Click in the map at the point to be assigned to the bottom contour 2 Click on the Zero icon All absorbance values equal to or below the absorbance at this point will be assigned to the bottom contour black
56. of the predefined Views can be found in the chapter titled Chapter 5 Viewing the Data gt Ifan operation is selected on the Views Tree the panes that appear in the right hand portion of the IRIS window consist of panes for displaying the required Chromatogram or Spectrum which you select from the Data Tree a Parameters pane which is used to set and investigate the various parameters used to determine the results of a particular operation a Results pane where the result of an operation is displayed and a Display List that contains a list of items you can select to display on the Results pane Detailed information on each operation can be found in the chapters titled Chapter 6 Spectral Librariesand Chapter 8 Performing Operations on Chromatograms 14 Chapter 1 Introduction The IRIS Menu Bar The IRIS Menu Bar located along the top of the program window contains the menu commands that enable you to process manipulate and display spectral data associated with chromatograms as described below NOTE The actual availability of menu items is determined by their privileges which are set in TotalChrom NOTE The symbol v in front of an item indicates that this is an on off toggle command The check mark appears in front of the item when the function is active or selected Menu Command Description File Open gt Displays a standard Windows file selector set to show the correct type of file rst for chromatograms uv for spect
57. perform an operation on a chromatogram in IRIS and save the results IRIS not only updates the chromatogram s spectral method IRIS also saves the parameter values to a Process Spectral Method that will be used by other chromatograms that are processed by the same TotalChrom method i e all chromatograms in this family 1 In IRIS open a chromatogram that has been processed with the TotalChrom method that has the same name as the Process Spectral Method you want to modify Note You can verify the name of the chromatogram s associated TotalChrom method by right mouse Clicking on the chromatogram in the IRIS Data Tree and selecting Information from the context menu that appears A Chromatogram Information dialog appears that shows the TotalChrom method associated with the selected chromatogram If the TotalChrom method has the same name as the Process Spectral Method you want to update then you can proceed to the next step If the TotalChrom method does not have the same name as the Process Spectral Method you want to update then open a different chromatogram and repeat the steps you just performed 2 If the TotalChrom method has the same name as the Process Spectral Method you want to update you can modify the Process Spectral Method by doing the following e For the chromatogram opened in Step 1 select any of the desired operations that are listed under Operations in the IRIS Views tree e Make any required changes to the parameters l
58. performing Peak Purity Wavelength Maximum and Printing Apex Spectra RST run SC LC EC Command for performing Spectral Standard Conformation Spectral Library Conformation and Extract Chromatograms RST Method C lt path file name gt tsm Command for executing a specified IRIS run PT Process Spectral Method and performing Peak Purity RST debug yes run pt print Command for displaying the debug window when AutoCalc runs These command allow you to check that AutoCalc is performing as you requested When these commands are specified the debug window will be displayed after the Peak Purity operation is performed and after the apex spectra output is printed 319 Iris HPLC Spectral Processing Software Using AutoCalc to print automatically the Apex Spectra display for each sample in a running sequence Using AutoCalc it is possible to print automatically the Apex Spectra display for each sample in a running sequence This is accomplished by specifying a Print command in the AutoCalc command line in the user Program section of a TotalChrom Method However before you add the Print command to the AutoCalc Command line you must follow the steps outlined in this section to specify the printing parameters that AutoCalc will use during a running sequence Steps you must perform before you can automate the printing of chromatograms annotated with apex specta As with all AutoCalc parameters
59. provides for various security levels that can be set in the TotalChrom SysConfig utility Therefore depending upon the permission level you have been assigned to in TotalChrom you are granted one of the following access levels to IRIS e Manager permission This permission grants a user full access to IRIS e User permission This permission provides a user with the ability to calculate and save chromatographic results However users with this permission cannot change methods or libraries Note For more information on methods refer to the chapter titled IRIS Spectral Methods e Read Only permission This permission provides a user with the ability to perform calculations as well as change any parameter values that are used in the calculation However users with this permission cannot save anything 44 Chapter 2 Enhanced Security Audit Trails IRIS provides you with an Audit Trail feature that tracks and records all changes made within the IRIS software All IRIS audit trails can be viewed on screen printed and exported It should be noted that audit trailing of Spectral Libraries is always enabled in IRIS On the other hand audit trailing of a chromatogram and its associated spectral methods is activated only when Audit Trailing is turned on in TotalChrom for a specific chromatogram In other words when Audit Trailing is turned on in TotalChrom for a specific chromatogram IRIS will create secure computer generated time stam
60. result file and the parameter values are added to the chromatogram s process spectral method file and the chromatogram s spectral method file 261 Iris HPLC Spectral Processing Software To display the Spectral Library Confirmation results in the Main View or Chrom Spectra View 1 Select Actions gt Label Chromatograms 2 Select Spectral Library Confirmation from the list of available labels To review for any chromatogram previously calculated Spectral Library Confirmation values and the parameters used gt Select this chromatogram again on the Spectral Library Confirmation operation 262 Chapter 8 Performing Operations on Chromatograms Peak Library Search The Peak Library Search operation allows you to easily identify all the peaks in a chromatogram by comparing the apex spectrum of each peak in a chromatogram to spectra contained in libraries that you specify gt To access this page expand the Operations node on the Views tree and select Peak Library Search Peak Search eet Peak Library Search amp Operations Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confir Spectral Library Confirma Minimum Wavelength 230 Maximum Wavelength 400 2 v PropyiBenzene 0 ButyiBenzene 0 Anthracene 0 Match Retention Time Window Peak Library Search LJ Retention Time Adjustme Extract Chromatograms vw gt 3
61. select from the Data Tree a Parameters pane which is used to set and investigate the various parameters that determine the results of a particular operation a Results pane where the result of an operation is displayed and a Display List that contains a list of items you can select to display on the Results pane It should be noted that the parameter values that are displayed on an operation come from the parameter values stored in a spectral method For more information about spectral methods refer to About Spectral Methods on page 28 For more information on Operations refer to the chapter titled Chapter 7 Performing Operations on Spectra on page 178 and the chapter titled Chapter 8 Performing Operations on Chromatograms on page 199 Iris HPLC Spectral Processing Software The Data Tree The Data Tree serves two functions e On the Main View Chrom Spectra View and Compare View the Data Tree displays a list of currently loaded chromatograms and spectra that are grouped by the parent chromatogram On these Views you use the Data Tree to select the chromatograms and spectra you want to see in the relevant panes chromatograms are displayed in the Chromatogram pane Spectra are displayed in the Spectra pane Items that appear checked on the Data Tree are displayed in the relevant panes while unchecked items on the Data Tree are not displayed e When specialized Views are displayed such as the 3D Spectra View or the Contour Map V
62. spectra Chapter 5 Viewing the Data Iris HPLC Spectral Processing Software IRIS Views You examine chromatograms and spectra from Views IRIS provides you with five default Views Main View Chrom Spectra View Contour Map View Spectra 3D View and Compare By default when IRIS is started the Main View is displayed However you can select any one of the five default views which are listed on the Views Tree to display the selected view on the right hand portion of the IRIS window The menu bar and tool bars always appear on the IRIS window You can also create your own Custom Views by modifying an existing view You can modify existing views by selecting to hide or show a particular pane To hide or show a pane on a view page select View gt Panes from the menu bar The Panes sub menu allows you to select whether or not a Chromatogram Pane Spectrum Pane Contour Map or 3D Plot is displayed on the View Once you have modified an existing view you can save it as a Custom View by selecting View gt View Template gt Save As from the menu bar Custom Views appear under the Custom node on the Views tree The data that is displayed on a View Page is controlled by the Data Tree From the Data Tree you select the chromatogram s and or spectra that you wish to display For more information on using the Data Tree refer to the section titled For more information on Operations refer to the chapter titled Chapter 7 Performing Operati
63. tab The Method tab page displays the Audit Trail of the Chromatogram s Spectral Method TSM having the same name as the TotalChrom Result file that was selected The Spectra tab page displays the Audit Trail of the source SPC file Audit Trail Method Spectral 0111 2006 08 40 AM Eastern Standard Time manager Signature Not Required 0111 2006 11 03 AM Eastern Standard Time manager Signature Validated 0141 2006 04 04 PM Eastern Standard Time manager Signature Validated 0111 2006 04 04 PM Eastern Standard Time manager Signature Validated 0143 2006 11 29 AM Eastern Standard Time manager Signature Validated Changes made Reason for change File c program files perkinelmer instruments iris data Initial creation in IRIS example 2 identified but with coelutiontsm created automatically as a copy of C Program Files PerkinElmer Instruments Wris Defautt tsm Comment Figure 2 4 The Method tab page on the Audit Trail Reader for a chromatogram Audit Trail Spectra fie created for raw file c program files perkineimer instruments wis datalEx4 raw File c progam fies perkinekner instruments Wis isatalEx4 spc created as a new fie Number of Spectra 1384 Number of Points per Spectrum 176 Figure 2 5 The Spectral tab page on the Audit Trail Reader for a chromatogram 51 Iris HPLC Spectral Processing Software Event Table The Event List displays a list of the events when changes were made
64. temporarily capture a chromatogram from the 3D Plot pane oo cee eee eee tte ee eter ee eee naan teeeeeees 119 How do close displayed chromatograms cccssseseeeeeeseeceeanseees 119 How do close all displayed spectra ccecce 120 Chrom Spectha VIEW casci tess cuts tev kan ia heeding een liseli 121 Contour Map VIEW cee eerie reer EEEE EEEE 122 Tell me about the Contour Map View 0cceceeeeeetesteeeeeeeeeeeeeeeae 122 How do adjust the pane width and height eeeeeeeeees 127 How do I view chromatograms and spectra on the Contour Map VIEW aisina arpana ninan a eiee es decihalpudehanes 128 Scaling a C to r Map asiriad nee eaa Daai nea EEan 129 How do I scale the Contour Map using the Normalize Point and Zero commandS neee 129 How do I use the Box Zoom on the Contour Map secere 130 How do I use the Autoscale tools on the Contour Map 006 130 How do I scale the Time Absorbance and Wavelength axes on the Contour Map ccccceeeeeeeeteeeeeeeeeeeeeeee 131 Spectra SD VIEW raian cat cach a aE AETA dot Ea oa raai 132 Tell me about the Spectra 3D VIEW cece cece tettteteeeeeeeee eee 132 How do adjust the pane width and height ceeeee ees 138 How do view chromatograms and spectra on the Spectra 3D View 139 How do rotate the display eee etter eee eeee ea nne 140 Scaling a 3D Plotesvce 5issscstevcns eats ones pe racine TE 141 How do specif
65. text on a Enables you to add or edit text on a graph porte o Switches on and off the Parameters pane on and off the Parameters pane Range Displays a range box enabling you to add all the spectra within the box to be added to the Data tree 25 Iris HPLC Spectral Processing Software Associated menu Description command Ha Add All to View Enables you to add spectra from Operations to the Data Tree Graph Enables you to change the formatting of the selected graph P pisplay Tool tips Determines whether tool tips are displayed or not PerkinElmer on the Links to www perkinelmer com web Zoom X Sets whether the zoom slider works on the X axis E Sets whether the zoom slider works on the Y axis x o zomz o Sets whether the zoom slider works on the Z axis Zoom sider Zooms in on the graph as set by the zoom tools 26 2D Graph Tool Bar Chapter 1 Introduction This tool bar contains commands that allow you to modify how chromatograms and spectra are displayed ICON Associated menu command x Stack Overlay g Autoscale X and Y L Autoscale Y only hie Normalize X and Y Wi Normalize Y only ian Offset Normalize Normalize Point E E Zero Previous scale E 3D Graph Tool Bar Description Switches the currently selected pane between a stacked display and an overlaid display Rescales the graph to the maximum and minimum of all data in the X and Y directions Resc
66. the chromatogram does not fall within the Hit Distance Threshold then the peak is labeled with an F indicating that the test failed Baseline corrected Check this option to use the baseline corrected spectra in the operation Library list Select this command button to display the Libraries List dialog from where you select the spectral libraries to search 259 Iris HPLC Spectral Processing Software Summary of Operation Spectral Library Confirmation The summary below illustrates how to optimize adjust the Spectral Library Confirmation results for a chromatogram and then save the new results and parameters used in the operation To review and adjust the Spectral Library Confirmation values for a chromatogram 1 From the Views tree expand the Operations node and click on Spectral Library Confirmation The Spectral Library Confirmation operation displays 2 If necessary open the required chromatogram using File gt Open gt Chromatogram 3 Select a chromatogram from the Data Tree The selected chromatogram is displayed The first peak is selected The results pane directly below the chromatogram shows for the selected peak its peak apex spectrum the matching library spectrum and optionally the baseline spectrum for the peak selected on the chromatogram and the baseline spectrum for the matching library spectrum To view the Spectral Library Confirmation values for a different peak gt Select the required
67. the Chromatograms tab page and Spectra tab page are enabled and these tab pages allow you to define the format for printing the contents of a chromatogram pane or a spectra pane Note The settings defined on the Chromatograms tab page apply to print outs only when a Chromatogram pane is currently selected on the view from where the Print dialog was accessed The settings defined on the Spectra tab page apply only when a Spectra pane is currently selected on the view from where the Print dialog was accessed Following is an overview of the setting available to you on the Print dialog General tab page This tab page is always enabled and allows you to select where and what you would like to print Printer Adobe PDF Preferences Orientation Portrait C Landscape Print What C All Panes In View Selected Pane Only Apex Spectra Print Cancel Figure 11 4 The General tab page The following options are available to on the General tab page 330 Chapter 10 Printing and Presentations Printer Select a printer from the drop down list Preferences Click on the Preferences button to define the settings for the printer Orientation Select to print either in Portrait mode or Landscape mode Print What Select one of the following radio buttons All Panes in View Prints the contents of the current IRIS window except for the Views Tree and Data Tree Selected Pane Only Prints only the c
68. the Main View you can temporarily preview and capture chromatograms from a spectrum However it is important to note that any chromatograms you capture from the Spectra pane are temporary and will be cleared from the display when you select a different view To temporarily preview and capture a chromatogram from a spectrum displayed on the Spectra pane the Chromatogram pane must use an overlaid display and the Spectrum pane must use a stacked display gt You can set the display modes for both panes by selecting Overlay Chromatograms and Stack Spectra from the View menu To temporarily capture a chromatogram 1 Click on any area in the white space of the Chromatogram pane 2 Set the selected Chromatogram pane to an Overlaid display by selecting Overlay Chromatograms from the View menu 3 Click on any area in the white space of the Spectra pane and set the pane to a Stacked display by selecting Stack Spectra from the View menu 4 Float your mouse pointer over a point on a displayed spectrum to temporarily view in the Chromatogram pane the chromatogram from that point As you continue to float your mouse pointer over the spectrum the Chromatogram pane automatically updates so that the chromatogram from the current location of your mouse pointer is displayed in the appropriate pane 5 If you see a chromatogram that you want to temporarily capture just double click on the spot in the spectrum that contains the chromatogram you wa
69. the information you want displayed on the Results pane including the spectra used in the calculation of the purity and the purity result Items that appear checked are displayed on the Results pane while unchecked items are not displayed The following items are available for selection on the Display List Upslope spectrum Check Upslope spectrum to display the upslope spectrum from the current peak Note You can define at what position of the peak height the upslope and downslope spectra are obtained The position is defined on the Parameters pane as a percentage of the chromatographic peak height The lower the percentage value that is entered for the Use at of Peak Height parameter the closer to the baseline are the spectra taken When looking for possible impurities spectral differences will be increased as you move further out on the peak i e closer to the baseline but the signal to noise will decrease and therefore increase the risk of false positives Downslope spectrum Check Downslope spectrum to display the downslope spectrum from the current peak Baseline Check Baseline to display the baseline spectrum from the current peak Purity Result Check Purity Result to display the plot resulting from the division of the upslope and down slope spectra at each wavelength ie ns OE s K 4 p Ud E Display E Upstope Downslope O Barctine Purty Healt 207 Iris HPLC Spectral Processing Software e R
70. the items that you want displayed in the right hand Chromatogram and Spectra panes 146 Chapter 5 Viewing the Data Chromatogram Panes The Chromatogram pane on the right hand side of the window displays the chromatograms that are checked on the Data Tree that is located on the right hand side of the window Conversely the Chromatogram pane on the left displays the chromatograms that are checked on the Data Tree that is located on the left hand side of the window Ipa Ja AG ap gN Ap Week Ate Ea ek pa fe ae fee ok fe ae wa G OS 11S 228398 4488660087 7S68088 147 Iris HPLC Spectral Processing Software Spectra Panes The Spectrum pane on the right hand side of the window displays the spectra that are checked on Data Tree that is located on the right hand side of the window The Spectrum pane on the left displays the spectra that are checked on the Data Tree that is located on the left hand side of the window 148 Chapter 5 Viewing the Data How do I adjust the pane width and height You can adjust the height and widths of any of these panes to make them smaller or larger To adjust panes 1 Place the pointer over the edge of the pane that you want to adjust The pointer turns into a line with arrows on each end ieee 2 Press the left mouse button and drag up down left or right The pane is resized after you release the mouse button The program maintains these settings until you adjust the panes aga
71. the upslope and down slope spectra For more information on how IRIS calculates Peak Purity refer to Appendix 1 on page 349 Note Use the Display List to specify what is displayed on the Results pane Items that appear checked on the Display List are plotted on the Results pane 202 Chapter 8 Performing Operations on Chromatograms Tell me about the Peak Purity operation The Peak Purity operation consists of the following areas e Views Tree The Views Tree provides you access to the Peak Purity operation Display B Upsiope Dormrlope o ay 8 203 Iris HPLC Spectral Processing Software e Data Tree The Data Tree displays a list of currently loaded chromatograms You use the Data Tree to select the chromatograms that you want to use in the operation The chromatogram you select from the Data Tree is displayed in the upper pane Chromatogram pane for this operation Display Upstope Downslope o i 2a 204 Chapter 8 Performing Operations on Chromatograms e Chromatogram Pane This pane displays the chromatogram that you selected from the Data Tree Each peak on the displayed chromatogram is labelled with its purity index and an associated Pass Fail Rating If the purity index for a peak exceeds the Purity Limit value currently displayed on the Parameters pane then the peak is considered impure and an F appears next to the purity value If the purity index for a peak is less than or equal to the
72. this section you select how chromatograms will be displayed on the print out As View Prints an image of the Chromatogram pane that is currently selected and displayed on the IRIS window Example n the example below we selected a Chromatogram pane on the Chrom Spectra View that contained two overlaid chromatograms We then selected File gt Print Selected Pane Only From the Chromatogram tab page on the Print dialog we then seelcted the As View option The first page of the print out contained a color coded key identifying each chromatogram included on the print out and the second page is shown below Operation Chrom Spectra View gt Date 07 13 2006 12 12 41 PM Eastern Standard Time PerkinElmer User manager Page 2 of 2 6 a 2 H 0 H i R e 8 3 0 2 o u E a a 8 Z a S i i 2 E 01 i 0 1 0 0 CREEP OO GENA AAA AEGA Pp ea A pape re ila epee et iota aoe Waite mages Wao aie ia Saat Gets peas Riek Wed Wee eae Overlaid Prints the chromatograms which are displayed on the currently selected Chromatogram pane using an overlaid display For an example of what the Overlaid print out would look like refer to the previous example for As View 333 Iris HPLC Spectral Processing Software Stacked Prints the chromatograms which are displayed on the currently selected chromatogram pane using a stacked display Example n the example below we se
73. to extract If desired you can also click the Browse button to specify a different TotalChrom method for the extracted chromatogram By default the Method field for the Extracted Chromatogram contains the same method as specified for the chromatogram selected on the IRIS Data Tree As soon as you enter a valid analytical wavelength the extracted chromatogram is displayed on this pane If you want to extract additional chromatograms select the next radio button and once again enter the parameters for the chromatogram Even without saving the results IRIS will remember the parameters you specified on each radio button you selected to create an extracted chromatogram until you select a new chromatogram from the Data Tree or leave the Extract Chromatograms operation You can save the extracted chromatograms and the parameters for the extracted chromatogram which can then be used by AutoCalc to automatically create multiple chromatograms during a TotalChrom sequence by selecting File gt Save Results from the IRIS menu bar For more information on using AutoCalc refer to Chapter 9 AutoCalc Automating Arithemtic Operations and Chromatographic Extractions Reference Ref Band A Method lex identified mith Pin Bome EETTTTETTFTETETTETETEYETETETTETETETETTETE mr o 11 22 33 06 77 88 gees A EAREND AHHH RENEE pHHEN He 295 Iris HPLC Spectral Processing Software How do modify the parameters that
74. to locate and view the chromatogram s Process Spectral Method which should be named ex 1 identified tsm The screen shot below shows the properties for this Process Spectral Method Method Viewer ex1 identified tsm General Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Printing General Details Last Edited Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment 4 9 2006 2 39 43 PM Extract Chromatograms Apex Optimized Chromatogram Description Audit Trail Figure 1 8 The Process Spectral Method for example 1 identified and well separated rst has the same name as the TotalChrom method used to process the result This method can be used by all chromatograms that are processed by the same TotalChrom Method When a Process Spectral Method is first created the parameter values for the method are copied from the parameter values in the Default Method Then whenever you perform an operation on a chromatogram in IRIS and save the results IRIS not only updates the Chromatogram s Spectral Method IRIS also updates the associated Process Spe
75. to the object The events are listed by date and time and the user who made the change When you click on an item listed here the Changes made section is populated with a list of changes made to the selected object Audit Trail Method Spectral 01 11 2006 08 40 4M Eastern Standard Time manager Signature Not Required 0111 2006 11 03 AM Eastern Standard Time manager Signature Validated 0111 2006 04 04 PM Eastern Standard Time manager Signature validated 0111 2006 04 04 PM Eastern Standard Time manager Signature Validated 0143 2006 11 29 AM Eastern Standard Time manager Signature Validated Changes made Reason for change File c program files perkinelmer instrumentsiiris data Initial creation in IRIS example 2 identified but with coelution tsm created automatically as a copy of C Program Files PerkinElmer Instruments ris Detault tsm Figure 2 6 The Events List for a chromatogram Changes Made When you select an event on the Event List the Changes Made text box displays the changes that were made for the selected date and time gt You can select any of the changes listed here to view the Reason for the change and a Comment associated with the change in the corresponding text boxes Note If you select a change from the Changes made list the Reason for change and Comment text boxes may not display any information if the user was not required to select a reason or enter a comment Reason for C
76. 0141 2006 11 03 4M Eastern Standard Time manager Signature Validated 01 11 2006 04 04 PM Eastern Standard Time manager Signature Validated 01 11 2006 04 04 PM Eastern Standard Time manager Signature Validated 0143 2006 11 29 AM Eastern Standard Time manager Signature Validated Changes made Reason for change File c program files perkinelmer instruments iris data Initial creation in IRIS example 2 identified but with coelutiontsm created automatically as a copy of C Program Files PerkinElmer Instruments ris Defaul tsm Figure 2 1 The Audit Trail Reader 48 Chapter 2 Enhanced Security Tell me about the Audit Trail Reader The Audit Trail dialog displays the audit trial for a specific object and consists of the following areas Tab pages The Audit Trail dialog displays tab pages that correspond to the type of Audit Trail you are viewing e When called from the Audit trail button on the Edit Library and View Library dialogs a Library tab page is displayed Audit Trail Library 11 28 2005 09 41 AM Eastern Standard Time manager Signature Validated 11 28 2005 09 42 AM Eastern Standard Time manager Signature Validated 11 28 2005 10 08 4M Eastern Standard Time manager Signature Validated 12 04 2005 05 03 PM Eastern Standard Time manager Signature Validated Changes made Reason for change Library Created with Add Apexes Comment Figure 2 2 The Audit Trail Reader for a Spectral Libra
77. 2 If necessary open the required chromatogram using File gt Open gt Chromatogram 3 Select a chromatogram from the Data Tree The selected chromatogram is displayed The first peak is selected The Results pane located directly below the chromatogram shows for the selected peak its Purity Index its upslope and downslope spectra the plot resulting from the division of the upslope and downslope spectra at each wavelength and optionally its baseline spectrum To view the Peak Purity value for a different peak gt Select the required peak by clicking on it in the chromatogram The Results pane is updated to show the Purity Index the upslope and downslope spectra for the current peak and the baseline spectrum for the selected peak The Purity Result for the current peak is also displayed The Purity Result is the plot resulting from the division of the upslope and downslope spectra at each wavelength To examine the Purity Values at different wavelengths gt Enter a new value for the Minimum Wavelength and or Maximum Wavelength The Peak Purity value labels are updated for every peak in the chromatogram To examine the effect of using baseline corrected spectra on the Peak Purity values gt Check Baseline Correct Spectra The Peak Purity value labels are updated for every peak in the chromatogram 211 Iris HPLC Spectral Processing Software To adjust the Minimum Absorbance value and the Minimum Data Points tha
78. 241 Iris HPLC Spectral Processing Software Parameters Pane This pane is where you set and investigate the various parameters used to perform the Spectral Standard Confirmation operation Whenever you change a parameter displayed on this operation and have a chromatogram selected on the Data Tree IRIS automatically updates the Display List and Results pane with the modified results Standard Cheomatogam 242 Chapter 8 Performing Operations on Chromatograms e Display List You use the Display List to select the information you want displayed on the Results pane When items appear checked on this list they are displayed in the Results Pane Meanwhile unchecked items are not displayed The following items are available for selection on the Display List Sample spectrum Check this item to display the spectrum from the selected peak on the sample chromatogram Standard Spectrum Check this item to display the spectrum from the selected peak on the standard chromatogram Sample Baseline Standard Baseline Check either of these items to display the baseline spectrum associated with each chromatographic peak SCC Check this item to display the result plot which is the line calculated by dividing the sample and standard spectra Note You can select Actions gt Add All to View to add all selected spectra in the Display list to the Data Tree 243 Iris HPLC Spectral Processing Software Results Pane This p
79. 41 Chapter 2 Enhanced Security Chapter 2 Enhanced Security Enhanced Security In response to Title 21 Food and Drug Administration of the United States Code of Federal Regulations CFR Chapter 1 Part 11 as well as the increasing data security requirements in other industries PerkinElmer has developed IRIS to work in conjunction with TotalChrom in order to provide you with the technical compliance tools needed to meet these regulations For example in IRIS enhanced security features such as electronic records controls and electronic signatures are supported for all data modified or created by the IRIS application More specifically the integration between IRIS and TotalChrom provides you with the following enhanced security features User Level Management and Security IRIS uses the secure login process provided by TotalChrom in order to control access to the application More specifically IRIS provides for three security levels that can be set in the TotalChrom SysConfig utility to control access to the application This means that users who are granted one type of access level may perform all IRIS functions while other users who are granted a more restrictive access level can use the software to calculate and save chromatographic results but are not able to perform functions such changing methods or libraries Audit Trails If Audit Trailing is turned on in TotalChrom for a specific chromatogram then IRIS will create secu
80. ALEN LELAS LALAN LALAN KAALI LALAN LLAKI LELEN LELAS LAEL ELLEN EELIS LELAND as 1 IS zZ 25 3 30 4 4S o5 0 AS 7 To G oo v Purity 5 56 J Display Upslope Downslope inna SS aa al O Baseline 200 225 250 275 300 325 350 375 Purity Result Login manager 4 Figure 8 1The Peak Purity operation 201 Iris HPLC Spectral Processing Software Checking the Purity of Chromatographic Peaks In order to perform the Peak Purity operation you must first select a chromatogram from the Data Tree The selected chromatogram is displayed on the page in the upper graph Chromatogram pane and each peak in the chromatogram is annotated with a Purity Index and a pass fail rating The purity indices and corresponding pass fail ratings are calculated according to the wavelength range pass threshold data point threshold and absorbance threshold values that are currently displayed on the page You can modify any of these parameters and IRIS automatically recalculates and displays the new purity indices for each peak in the chromatogram If you are interested in seeing how the peak purity was evaluated for a specific peak simply click on that peak The Results pane located beneath the chromatogram display provides you with a graphical representation of the upslope down slope and baseline spectra for the selected peak as well as a graphical representation of the purity difference which is a plot resulting from the division of
81. Adistme Estat Oronsteyans w gt DOU CORLL GeO CCU CR EO COR CO Bd tt 22 32 a4 es to 77 ue fiee poet separ steco f ila Pray leiwere C Wragg ann Fie Perk rE mer Incturnerts ine apex ab 258 Chapter 8 Performing Operations on Chromatograms How do modify the parameters that are used in the search The Parameters pane is where you set and investigate the various parameters for perform the Spectral Library Confirmation on a chromatogram that is currently selected on the Data Tree Once you have a chromatogram selected on the Data Tree you can optimize adjust the parameters that are displayed on the screen at any time and IRIS automatically updates the display with the new results Below is a list of the parameters you can optimize adjust Parameter Description Minimum Use the Minimum Wavelength spin box to set the lower limit of the Wavelength spectrum range to be used in the calculation Maximum Use the Maximum Wavelength spin box to set upper limit of the Wavelength spectrum range to be used in the calculation Hit distance Use the Hit Distance Threshold spin box to specify the Hit Quality threshold above which two spectra will not be considered a match The results of the match are displayed as labels for each peak on the chromatogram If the match for a peak on the chromatogram meets the Hit Distance Threshold specified then the peak is labeled with a P to indicate the test passed If the match for a peak on
82. Chrom Spectra View that contained five overlaid spectra We then selected File gt Print Selected Pane Only From the Spectra tab page on the Print dialog we then selected the Stacked option The first page of the print out contained a color coded key that identifying each spectrum included on the print out and the second page is shown below Operation ChromySeectra View gt Date 07 13 2006 12 56 25 PM Eastern Standaed Time Perkin imor User manager Page 20f2 a ea R Tae A el RL i a TEE 338 Chapter 10 Printing and Presentations Separate Plots Prints each spectrum that is displayed on the currently selected Spectra pane on separate plots When this option is selected the per page spin box is enabled and from this spin box you specify the number of plots that will be printed on each page Example n the example below we selected a Spectra pane on the Chrom Spectra View that contained five overlaid spectra We then selected File gt Print Selected Pane Only From the Spectra tab page on the Print dialog we then selected the Separate Plots option and selected to print 2 spectra per page The first page of the print out contained a color coded key identifying each spectrum included on the print out and the second page is shown below this report also contained a third page displaying two spectra and a fourth page displaying the final spectrum Note Since the example above contained more than two spectra the r
83. Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram E Printing Last Edited Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search 4 9 2006 2 39 43 PM Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Description Audit Trail Note If you have the appropriate user permissions you can edit the default method by selecting Tools gt Edit Default Method from the IRIS menu bar For more information on editing the default method see the topic titled Method Editor 33 Iris HPLC Spectral Processing Software How do I view the parameter values in a spectral method To view the parameters in a Chromatogram s Spectral Method 1 From the IRIS workspace select File gt Open gt Method The Select Method dialog box appears 2 Select a spectral method to view and click Open The View Method dialog displays OR If you have opened a chromatogram in IRIS right mouse click on the chromatogram listed on the Data Tree and select View Method from the context menu that appears The View Method dialog is displayed To view the parameters in a Process Spectral Method 1 From the IRIS workspace select File gt Open gt Method The Select Method dialog box appears 2 Select a sp
84. IRIS HPLC SPECTRAL PROCESSING SOFTWARE User Manual P gt PerkinElmer precisely Iris HPLC Spectral Processing Software Release History Part Number Publication Date 0993 6807 July 2006 Any comments about the documentation for this product should be addressed to User Assistance PerkinElmer Ltd 710 Bridgeport Avenue Shelton CT 06484 Or emailed to info perkinelmer com Notices The information contained in this document is subject to change without notice Except as specifically set forth in its terms and conditions of sale PerkinElmer makes no warranty of any kind with regard to this document including but not limited to the implied warranties of merchantability and fitness for a particular purpose PerkinElmer shall not be liable for errors contained herein for incidental consequential damages in connection with furnishing performance or use of this material Copyright I nformation This document contains proprietary information that is protected by copyright All rights are reserved No part of this publication may be reproduced in any form whatsoever or translated into any language without the prior written permission of PerkinElmer Inc Copyright 2006 PerkinElmer Inc Produced in the US Trademarks Registered names trademarks etc used in this document even when not specifically marked as such are protected by law PerkinElmer is a registered trademark of PerkinElmer Inc T
85. Ly Ft 0 5 4 15 2 25 3 35 4 45 5 55 6 65 7 75 8 8 5 9 M example 1 identified and well 6 315 320 325 330 335 anga 946 350 355 360 365 370 375 380 385 390 395 400 Login manager amp A Figure 4 12 Detailed examination using Normalize Point 99 Iris HPLC Spectral Processing Software Additional Options for Scaling Spectra In addition to the Autoscale and Normalize commands IRIS offers the following additional options for scaling spectra Use the Box Zoom function to visually specify an area of the display you want to zoom into Use the Format Graphs dialog to scale spectra by specifying the axis range Zoom in a continuous fashion How do I visually specify an area of the display to zoom into using the Zoom Box function It is possible to zoom into a visually defined region of a spectrum using the Box Zoom To scale individual spectra set the Spectra pane to Stacked mode To zoom into a visually defined region 1 4 Move the mouse cursor inside the plot region and position it at a corner of the area you want to zoom Hold down the left mouse button and drag the mouse to form a box around the area to be zoomed Release the mouse button The region you wish to zoom into will be outlined with a box containing eight control points The box can be resized by clicking and dragging on any of the control points Move the mouse pointer into the zoom region and click the left mouse button Not
86. Name of the person creating the file recorded automatically The reason will be automatically recorded as File creation Note Any file with a corrupted audit trail can only be accessed in read only mode to allow for investigation of the failure and cannot be used for any IRIS or TotalChrom processing or data generation 46 Chapter 2 Enhanced Security Entering Audit Trail Information When audit trailing has been enabled in TotalChrom for a specific chromatogram and a user attempts to make any changes in IRIS to the chromatogram and its associated spectral methods the user is prompted with the Audit Trail dialog In addition any time a user attempts to modify or create a spectral library an Audit Trail dialog displays The Audit Trail dialog displays the user name of the individual who is currently logged in and the date and time of the event In addition your application manager may have set up the system to require you to select a reason for the event and you also may be required to or have the option to enter a comment about the event To enter audit trail information when the Audit Trail dialog is displayed Note Your application manager may have set up the system so that you must select a Reason from a list that is displayed when the Audit Trail is triggered Or you may be able to enter your own reason for the event that triggered the Audit Trail dialog 1 Select or enter a reason for the change s in the Reason li
87. Printer Adobe PDF Preferences Orientation Portrait Landscape Print What All Panes In View Selected Pane Only Apex Spectra Figure 11 1 The Print dialog 327 Iris HPLC Spectral Processing Software What information is included on printouts After you have defined your printing preferences on the Print dialog and clicked on the Print button a print out of your selections is generated On the first page of each print out the following information is provided e A title for the document being printed This title is set by IRIS e The complete color coded source identification information for all displayed objects in the report The first page s of the printout color coded list all of the chromatograms spectra printed on the report so that you can easily identify the source Please note that this information may be printed on more than one page Note This page does not apply to Apex Spectra printouts e A date and time stamp of the printing in the time zone where the printing occurred e The User name and full name of the person generating the report that is the person logged in to the software e The page number in the form of Page X of V Operation Chrom Spectra View Date 07 11 2005 12 57 18 AM Eastern Standard Time User manager Page 1of2 Chromatograms K Filename example 1 identified and wel separated rst Path c iris data data data data Spectra A Filenam
88. Purity Limit currently defined on the Parameters pane then the peak isconsidered pure and a P is displayed next to the purity value Note A purity index of 1 00 means that a peak is homogeneous most likely consisting of a single component A high value means that the upslope and downslope spectra are quite different and the peak is highly impure Typically a peak with a purity value of 1 00 to 1 50 is considered pure IRIS uses an initial default value of 1 5 for the Purity Limit however you can specify a different maximum value at which the upslope and downslope spectra are considered to match using the Purity Limit parameter that is displayed on this view OX 205 Iris 206 HPLC Spectral Processing Software Parameters Pane This pane is where you set and investigate the various parameters used to calculate Peak Purity Whenever you change a parameter displayed on this operation and have a chromatogram selected on the Data Tree IRIS automatically updates the Display List and Results pane with the modified results For more information on the Peak Purity parameters see How do on page 209 Peak Puny Momm Wavelength e 3 Magam Wavelength 700 Mineoum Data Ports 7 T Baseine Conect Spectra Use ot of Pook Height Bucky Lint a Display Upstope Dosmihipo o x Chapter 8 Performing Operations on Chromatograms e Display List You use the Display List to select
89. RST and can be automatically included in a TotalChrom Report For more information on automating arithmetic operations and chromatographic extractions refer to the chapter titled AutoCalc Automating Arithmetic Operations Extractions and Apex Spectra Printing 200 Chapter 8 Performing Operations on Chromatograms Peak Purity The purity of a chromatographic peak can be checked by comparing the spectra on the upslope and down slope of the peak If the two spectra are not the same then two or more components with different spectra must be present in the peak envelope In IRIS you use the Peak Purity operation to calculate the peak purity for all peaks in a specific chromatogram gt To access the Peak Purity operation expand the Operations node on the Views tree and select Peak Purity Peak Purity Operations Library Match r z Minimum Wavelength Spectral Derivative 0 a Spectral Math 4 z M Peak Purity Absorbance Ratio Wavelength Maximum 7 400 Spectral Standard Confirma _ Spectral Library Confirmatio gt Minimum Data Points Peak Library Search gt 5 Retention Time Adjustment z Extract Chromatograms IV Baseline Corect Spectra Apex Optimized Chromatogi Custom Views w lt m Maximum Wavelength ar Ne Purity Limit Use at of Peak Height 15 4 20 4 example 2 identified but with coe sz 4 Absorbance Threshold example 1 identified and well sep 5 Auto C Manual ERD RRS CLEAS OO OD K
90. S then IRIS creates the new Chromatogram s Spectral Method by copying the parameters values from its associated Process Spectral Method the Process Spectral Method is the method associated with all chromatograms that have been processed by the same TotalChrom method and is used by AutoCalc The example below shows the spectral method that was created the first time the following example chromatogram example 1 identified and well separated rst was opened in IRIS You can access the dialog shown below by right mouse clicking on a chromatogram from the IRIS Data Tree and selecting View Method from the context menu that appears Note The example chromatogram referenced above is located in the IRIS Data directory which is installed as part of the IRIS Installation process The tsm spectral method file is not installed with IRIS but rather it is created the first time you open the chromatogram in IRIS Method Viewer example 1 identified and well separated tsm General Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Printing Audit Trail Figure 1 6 A Chromatogram s Spectral Method controls what you see when you select a chromatogram on an operation in IRIS it also contains a record of the parameters used to
91. Tell me about the Edit Library Dialog Edit Library Library Details pt A a es Name example3 alb Description ee Minimum Wavelength Maximum Wavelength 190 400 Spectra Current Spectra Library MV Show baseline corrected spectrum Show baseline spectrum Audit Trail B Figure 6 1 The Edit Library dialog 162 Chapter 6 Spectral Libraries The Edit Library dialog consists of the following controls The file name of the library appears here Description You can enter or edit a description for the library in this text box The description you enter here will help you identify the library later on when you are performing Operations in IRIS that require you to select a list of libraries to be searched Minimum The minimum wavelength of the spectra in the library is displayed Wavelength here Maximum The maximum wavelength of the spectra in the library is displayed Wavelength here Current Spectra This list box shows all the spectra currently listed on the Data Tree branched by chromatogram You can select a spectrum from this list and then use the Add command to add the Spectra to a Library When you add a selected spectrum you are prompted to enter the component name of the spectra before it is added to the library OR You can select a spectrum from this list that you wish to use to replace a Library component To replace a component you must first select the component from the Library list
92. a chromatogram and then label the peaks in that chromatogram with the results To identify the peaks in a chromatogram using a library s of standard spectra 1 From the Views tree expand the Operations node and click on Peak Library Search The Peak Library Search operation displays 2 If necessary open the required chromatogram using File gt Open gt Chromatogram 3 Select a chromatogram from the Data Tree Note Ifthe Peak Library Search operation has not been previously performed on the chromatogram that you just selected the Libraries List dialog is displayed from where you must select the spectral libraries you want to search This dialog is not displayed if the Peak Library Search operation has already been performed on the chromatogram and the results were saved via the File gt Save Results command Instead the Peak Library Search operation is displayed and the previously selected library ies are automatically selected for the operation The selected chromatogram is displayed and the first peak is selected Note that each identified peak on the chromatogram is labeled with the Component Name of the best match as well as the Hit Quality Value a numerical value that indicates how close the peak apex spectrum matches the component name from the matching library spectrum the lower the Hit Quality Value the closer the match If IRIS could not find a match for a peak the unmatched peak is labeled with Not Found In addi
93. able Of Contents Table Of Contents Table OF Contents sscie eonia siacs Gasameees einen As aoa eee i Chapter 1 Introduction ccssceeesseseeeeeeeeseeeeeeeeeeeeenaaeeeeeaeeeeeeeaseenenoes 1 WAT OCU CLIO M sie ak A E E EA 2 About IRIS Spectral Processing Software cceeeececteeeeeeeeeeee saan eeeeeerees 3 Features Of IRI Sis cai sdecnOiatstaautia die lvuds Ma are aie e a Midas aia aides 4 St ring RIS aite tyes T aAA E AT Settee EEE eK 5 Starting IRIS from WiNdOWS cece eee eect etree nett e eee ee eee ernes 5 Starting IRIS from TotalChrom e cece eeee eee e eee ee eeeeeeeeeenaaneeees 6 Overview of the IRIS User Interface cece rerne 7 TNE VIOWS TOG ose tech dbaker sets A 8 Tell me about the Views and Operations that are listed on the Views Tree e cece cece eeee eee ee ae a tee tent eeeeeaaaaaneetereeeeeaaaga 9 MNS Data Treerne neen oni twee viaiens vinwiwiyei AE Eaa ogai 9 Panes for Displaying Chromatograms Spectra Contour Maps and 3D PIOtS s sseesssssisiirineestsrrirrrerrenrrirrerennnn nnna 14 The IRIS Menu Bat cccccssscseecseeeecescueeeeeseaeesesseesesesesseesereeaenseeeeaes 15 IRIS TOOl Barsine riega i AAAA DE EEE E E et ole 25 About Spectral Methods 00 0 0 ee ete reer eae rene nnne 28 Default Method s ici26sccnccevees ivecadacelbecncdswecneeelssvecareasel eeavhuvecceuenensetiys 29 Chromatogram s Spectral Method cece cece cess eeteeeeeeeeeee ee enaae 30 Process Spectral Method
94. ables the edge to be stretched Upon releasing the mouse the range box is deactivated Positioning the mouse pointer over the left or right edge of the box except for the position of the handles changes it to a four headed arrow and click and hold enables the complete box to be moved Upon releasing the mouse the range box is deactivated e Positioning the mouse pointer within the box and double clicking loads all the spectra enclosed by the box into the Data Tree and sets them as selected The range box is cleared Clicking on the chromatogram but outside of the box clears the range box Note Range is also an option in the Context menu for a stacked chromatogram 21 Iris HPLC Spectral Processing Software Menu Command Add All to View Tools View Library Build Library gt Create Add Apexes Edit TotalChrom gt Reprocess Graphic Method 22 Description Used both for adding spectra that have come from library searches mathematical operations etc to the Data Tree so they can be viewed on other views and for permanently displaying spectra temporarily displayed on a View Enabled in Views at any time a spectrum is temporarily viewed or in Operations when a spectral graph is selected that includes spectra that are not currently part of the Data Tree When the user selects the Add All to View command in any Operation a Response dialog appears that informs you that spectra have been added to the Data Tre
95. age 87 This command allows you to save the results and the parameters used in an operation performed on a chromatogram Refer to the section titled Saving the Results of a Calculation on page Error Bookmark not defined for more information If a spectrum is selected on the Data Tree and you select File gt Save As from the menu bar a standard Windows file selector appears From this dialog box you can save the spectrum as a uv file An audit trail entry is created for this newly created file that identifies the source of the chromatogram the user s full name and logon name as well as a date and time stamp If a chromatogram is selected on the Data Tree and you select File gt Save As from the menu bar a standard Windows file selector is displayed From the dialog box that appears you can name and save the chromatogram with a RAW extension Displays a Print dialog from where you specify which details you want to print from the current view and which printer you want to use Enabled at all times Menu Edit View Command AutoCalc Print Setup Copy Object Copy Screen As gt Bitmap Metafile Chromatogram Baselines v Baseline Spectra Chapter 1 Introduction Description If you plan on using AutoCalc to automatically print out the Apex spectra display for each sample in a running sequence then you can use this command to specify details of that output including the printer to be used Fo
96. aid Prints the spectra which are displayed on the currently selected Spectra pane using an overlaid display Stacked Prints the spectra which are displayed on the currently selected Spectra pane using a stacked display All of the spectrta are printed on one page Separate Plots Prints each spectrum that is displayed on the currently selected Spectra pane on separate plots When this option is selected the per page spin box is enabled and from this spin box you specify the number of plots that will be printed on each page When finished click Print Chapter 10 Printing and Presentations How do I print a chromatogram and its associated apex spectra 1 From the Data Tree click on the chromatogram you want to print along with its associated apex spectra from the Data Tree 2 From the IRIS menu bar select File gt Print The Print dialog appears General Printer Adobe PDF Preferences Orientation Portrait Landscape Print What C All Panes In View C Selected Pane Only Known Peaks Only C Peaks with Absorbance Over pos ie 3 Click on Apex Spectra to print the chromatogram that is currently selected on the Data Tree and its associated apex spectra 347 Iris HPLC Spectral Processing Software 4 When Apex Spectra is selected you must also select whether or not you wish to print All of the apex spectra or just the apex spectra from known peaks or to print the apex
97. al Library Confirmation and Peak Library Search 3 Select Currently identified peaks to only save results for peaks that are currently identified named in TotalChrom If you select this option results are not saved for unidentified peaks OR Select Include unidentified peaks to save results for identified and unidentified peaks If you select this option any unidentified peaks that have results calculated are added to the results file as Unknown 1 Unknown 2 etc Any unidentified peaks which do not have results are not added to the file 4 Click Yes to save the results and calculation parameters The results are added to the TotalChrom result file and can now be included in a TotalChrom printed report See the section titled How do I include the results of chromatographic operations performed by IRI S AutoCalc in a TotalChrom report on page 312 Note The report format AppValues npt which is present in the installed example data directory can be used to print out the saved results in the RST file from all of the operations in R S AutoCalc 309 Iris HPLC Spectral Processing Software How IRIS saves Information to TotalChrom The results of any of the operations you perform on a chromatogram in IRIS can be saved to the chromatogram s result file RST and the parameters that were used calculate the results are saved the associated spectral method files TSM The saved results can to be included in a printed TotalCh
98. al Processing Software Opening a Chromatogram You can open a chromatogram at any time while using IRIS by following the steps listed in this section However to help you get started this chapter will show you how to open and work with chromatograms on the Main View To open a new chromatogram 1 From the IRIS menu bar select File gt Open gt Chromatogram The Open Chromatogram dialog appears 2 Select the result file RST that you want to open and click Open The Open dialog closes and the chromatogram you just opened is now checked on the Data Tree and displayed on the current view if the view contains a pane for displaying chromatograms For this example the newly opened chromatogram appears checked on the Data Tree and is displayed on the Main View in the following panes Chromatogram pane Contour Map pane and 3D Plot pane To hide the chromatogram from being displayed on the Main View simply uncheck the chromatogram on the Data Tree DEK File Edit view Actions Tools Help i i alalolelalalenlal el aam eel o Pe o st Lamu ual ales Elie g Ke gt Main View Chromatograms iews Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom views CTO oaa oron oan LO EU PL WT DO DL EO KT 0 611 622 533 544 556 666 577 583 59 0 611 522 833 544 555 566 577 683 59 example 1 identified and well seg 9 ER LERLE LILET LELLE LERIN ELLEI LELES
99. alChrom Help file To use the AppValue rpt 1 In TotalChrom Reprocess Results open the result file that you want to use to generate a report 2 Select File gt Report Format 3 Locate and select the AppValues rpt as the report format The report information display changes according to the new format you selected 312 Chapter 9 AutoCalc Automating Arithmetic Operations Extractions and Apex Spectra Printing Iris HPLC Spectral Processing Software What is AutoCalc AutoCalc is a user program that is installed with your IRIS Spectral Processing Software During a TotalChrom TC sequence this user program allows you to automatically perform any combination of the arithmetic operations with the exception of Apex Optimized Chromatogram provided by IRIS such as Peak Purity and Spectral Standard Confirmation This program also allows the automated extraction of up to 8 chromatograms and printing of chromatograms annotated with apex spectra This is all achieved by specifying AutoCalc exe as a user program in the Process section of a TotalChrom TC method and entering the desired series of AutoCalc commands in the command line It is important to note that as part of either a real time or reprocessed sequence the results of the automated operations are automatically saved to the TotalChrom Result file RST and can automatically be included in a TotalChrom report 314 Chapter 9 AutoCalc Automating Arithmetic Operatio
100. ales the graph to the maximum and minimum of all data in the Y direction only Normalizes the graph so all plots are full scale Normalizes the graph so all plots are full scale without changing the X axis Normalizes all plots to the highest point to the right of the cursor position Normalizes all plots at the cursor position Sets the point at the cursor position to zero Steps back through previous scale changes This toolbar contains commands for rotating a 3D Plot Icon Associated Menu Command L Rotate X A Rotate Y Rotation slider Description Sets rotation slider to rotate around the X axis Sets rotation slider to rotate around the Y axis Rotate around the set 3D rotation control axis 27 Iris HPLC Spectral Processing Software About Spectral Methods In Chapter 8 Performing Operations on Chromatograms you will learn about the chromatographic operations in IRIS which allow you to obtain important information about your chromatograms These operations include Peak Purity which checks the homogeneity of each peak in the chromatogram Peak Library Search which identifies each peak in the chromatogram by comparing its spectrum to a spectral library and Spectral Standard Confirmation which confirms the identity of each peak in the chromatogram by comparing its spectrum to the spectrum from the same named peak in a reference chromatogram However before you begin performing these operations it is
101. amed peak on the chromatogram by clicking on the peak When you select a named peak on this pane the peak with the same name is selected on the Standard Chromatogram pane and vice versa If the selected peak in the sample chromatogram has no equivalent in the standard chromatogram the message No corresponding component in standard is displayed on the Result pane Chapter 8 Performing Operations on Chromatograms Standard Chromatogram Pane This pane displays the standard chromatogram that you have selected When the standard chromatogram is first displayed the peak matching the peak selected in the sample chromatogram is automatically selected You can select any other identified peak in the standard by clicking on it The corresponding peak in the Sample is then automatically selected If you want to change the chromatogram that is displayed on this pane you can click on the Standard Chromatogram button which is located on the Parameters pane for this operation and select a different standard chromatogram from the dialog box that appears If you open a standard chromatogram with a method that does not match the sample chromatogram a warning message is displayed that states Sample and Standard chromatogram methods do not match Meanwhile if the selected peak in the standard chromatogram has no equivalent in the sample chromatogram the message is displayed No corresponding component in sample on the Results pane
102. ameters Pane on the Library Match operations contains the following parameters ou can modify so al Iris re runs the match and updates the Hits List and Hits Pane Controt O Descri Description o O Minimum Wavelength This spin box is where you set the minimum wavelength to be used for the match Maximum Wavelength This spin box is where you set the maximum wavelength to be used for the match Match retention time Check this field to select the retention time of the spectrum window as one of the search criteria When this field is checked a spin box appears from where you specify the search window as percent of retention time Baseline corrected Check this field so that the sample spectrum and the spectra in the libraries being searched are used with baseline correction If this field is not checked baseline corrected spectra will not be used for the library match Note Checking this option affects the results of the operation however this option does not change the sample spectrum displayed in the top pane To baseline correct the sample spectrum displayed in the top pane select View gt Baseline Corrected Spectra Library List Click on this command button to display the Library List dialog from where you select the libraries that will be searched Note If Match retention time window is checked the search first creates a list of all spectra in the library that fall within the window it then does a spectrum by spe
103. ams The Context Menu for the Chromatogram pane When you right click on a Chromatogram pane a context menu appears that contains the following commands Note When the Chromatogram Pane Is in Stacked mode each of the chromatograms has its own context menu When the Chromatogram Pane is in Overlay mode the context menu items apply to all chromatograms Print Pane Prints the current pane v Chromatogram Baselines Displays or hides baselines on all chromatograms as a red line Overlay This command toggles between Stack Chromatograms and Chromatograms Stack Overlay Chromatograms and determines how the contents of Chromatograms the pane are displayed This option is not available when the Chromatogram Pane is displayed on an Operations page When Overlay Chromatograms is selected all chromatograms are displayed on one set of axes and the menu command changes to Stack Chromatograms When Stack Chromatograms is selected all chromatograms are displayed on separate exes and the menu command changes to Overlay Chromatograms v Cursor Toggles the cross hair cursor on and off Hide Pane Hides the chromatogram pane forming a custom view This option is not available when the Chromatogram Pane is displayed on an Operations page Label Chromatograms Displays the Label Chromatograms dialog This option is not available when the Chromatogram Pane is displayed on an Operations page 61 Iris HPLC Spectral Processing S
104. ane displays a graphical representation of the items that are checked on the Display List If the selected peak on the sample chromatogram matches the selected peak on the standard chromatogram then the Results pane also displays the Absorbance Index By default the Absorbance Index is displayed in the upper right hand corner of the pane as Al Note Whenever you select a different peak change the parameters for the operation or select deselect an item on the Display List the Results pane is automatically updated to reflect the change 244 Chapter 8 Performing Operations on Chromatograms How do modify the parameters that are used to perform the Spectral Standard Confirmation operation The Parameters pane displays the values that are currently used in the operation At any time you can modify the parameters that are listed on the Spectral Standard Confirmation operation and IRIS automatically updates the display with the new results Below is a list of the parameters you can modify Minimum Wavelength Specify the minimum wavelength to be used Maximum Wavelength Specify the maximum wavelength to be used Minimum Data Points The absorbance threshold value will eliminate certain data points from the calculation of the result If too many data points are eliminated the result becomes questionable Therefore use the Minimum Data Points spin box to set the minimum number of data points that must be present for th
105. ane displays the chromatograms that are checked on the Data Tree When this pane is in Stacked mode as indicated when the stacked icon appears to be Aa pressed down x and the Spectra pane is set to Overlay mode as indicated when Aan the stack overlay icon appears Bs you can float your cursor over a point on the Chromatogram pane and have the associated spectrum temporarily displayed in the Spectrum pane You can also extract a spectrum by double clicking on the area in the Chromatogram pane that contains the spectrum you wish to extract The extracted spectrum is added to the Data Tree and displayed in the Spectrum pane Views Data 110 Chapter 5 Viewing the Data Spectra Pane The Spectra pane displays the spectra that are checked on the Data Tree Fle Edt View Actors Toos Hep s12 3 Glalgi2inial gt wi foloie ayla Ol Falealea erie e SSESIERE Lin ory Match Spectral Derivative Sonta Math Posk Purty Absorbarce Ratio Wavelength Maximem Spectral Rafard Corfrmatan yy PEDERI 111 Iris HPLC Spectral Processing Software e Contour Map This pane displays stacked contour maps for all chromatograms that appear checked on the Data Tree The stacked contour maps appear in the same order as the chromatograms displayed on the Chromatogram pane You can float your mouse pointer over this pane to temporarily view a single spectrum and chromatogram from a point on the Cont
106. ap View or 3D Spectra View to perform this task You can also capture spectra by double clicking your mouse over an area on the chraomtogram and the spectrum at the wavelength and time you clicked appears in the Spectra pane for the current view The spectrum is also added to the Data Tree under the chromatogram from which the spectrum was extracted Note A captured spectrum is a spectrum extracted from its source and displayed permanently in the Spectra Pane A captured spectrum can be hidden and or removed Note You cannot use the File gt Open gt Spectrum command to access a spectrum associated with a chromatogram Individual Spectra These are the files that result when you select a chromatographic spectrum that you have extracted and then select the spectrum on the Data Tree and then use the Save As command Note that you must first extract and display the spectrum you cannot save spectra directly from a chromatogram to a file Only this type of spectrum can be opened using the Open gt Spectrum option under the File menu Library Spectra You can use the Add Apexes command to automatically create a spectral library using the apex spectra from named peaks in a chromatogram You can also add a previously stored individual spectrum to a library to do this you must first open this spectrum in IRIS and then use the Build Library commands located under the Tools menu In addition spectra extracted from a chromatogram ca
107. at states The items selected for closing include data that has not been saved Do you want to continue Click the Yes button on the message dialog to save the Data Chapter 5 Viewing the Data Chrom Spectra View The Chrom Spectra View page functions similar to the Main View both views are designed for viewing unlimited chromatograms and spectra at one time However unlike the Main View which shows you chromatograms spectra contour maps and 3D plots the Chrom Spectra View just shows you the chromatograms and spectra that are checked on the Data Tree For more information on how to use the Chrom Spectra View refer to the information found in the section titled Tell me about the Main View on page 107 ae fe el File Edit View Actions Tools Help Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views We si ae 1 613 2 464 3 667 E E EEE 200 225 250 350 Login manager amp Figure 5 2 The Chrom Spectra View 121 Iris HPLC Spectral Processing Software Contour Map View The Contour Map View is intended to help you explore complex chromatographic data This view gives you a wide array of tools for visual investigation of chromatographic and spectroscopic features Note Although this page allows you view spectral and chromatographic data during analysis the data cannot be stored for use in other areas of the IRIS program More specifically the Contour Ma
108. ation you must select a chromatogram that is listed on the Data Tree Next you must specify the spectral libraries to be searched IRIS then matches each named peak in the chromatogram to a library spectrum that has the same component name As a result of the search each named peak on the chromatogram that could be matched to a library spectrum with the same component name is labeled with the Component Name a Hit Quality Value a numerical value that indicates how close the apex spectrum matches to the library component of the same name and a Pass Fail value that indicates whether or not the component from the sample chromatogram matches the library component based on the Hit Threshold you specify Note Ifthe chromatogram that you selected on the Data Tree has no identified peaks IRIS informs you of the error and you will not be able to perform this operation Only identified peaks can be matched If you are interested in the Spectral Library Confirmation for a specific peak simply click on the peak you wish to evaluate Below the chromatogram plot an overlaid plot of the apex spectrum for the currently selected peak is displayed along with the library spectrum with the same component name How does IRIS perform Spectral Library Confirmation As stated earlier the Spectral Library Confirmation operation verifies the identity of named peaks in a sample chromatogram by comparing the apex spectrum of each named peak in the sample to an i
109. atogram at the wavelength and time you clicked appears in the chromatogram pane Note Chromatograms that are displayed on this pane are only temporary and will be cleared when you leave the Contour Map View 126 o gt 44 q i 3 iy 1 J j Chapter 5 Viewing the Data e Spectra Pane This pane displays the spectrum from the point selected on the Contour Map To display a spectrum on this pane simply float your mouse pointer over the Contour Map and the spectrum from that point is temporarily displayed on the Spectra pane If you want to extract a spectrum from the Contour Map just double click on an area in the Contour Map and the spectrum at the wavelength and time you clicked appears in the Spectra pane Note When you extract a spectrum from the Contour Map the spectrum is added to the Data Tree however you will not see the extracted spectrum listed on the Data Tree until you exit the Contour Map View The reason for this is because while you are viewing the Contour Map View the Data Tree is used only for selecting the chromatogram that you want displayed on the view You will be able to see the extracted spectra once you select a different view such as the Main View or the Chrom Spectra View 7 WU UE CEEOL CO CLE How do I adjust the pane width and height You can adjust the height and widths of any of these panes to make them smaller or larger To adjust panes 1 Plac
110. ayed in the top graph Chromatogram pane Fie Ede Wew Actions Took Heb 3 8 33 o igl2 Mini u faloin wy yiose oO Be el aloe Reterhon Tine Aduutmert Cheom Spectrs Cortow Map Spectra Compare Oper ations Liteary Match Spectral Derivative Specu ad Math Peak Asty Fincrborce Ratio Wevelangth Maven Spectral Randed c 7 famine Conect Specta Spectral Lte ary Cor Pash Lie ary Search Retordion Tene Ads Extract Oromstoy Apex Optmisod Or Meong Wavreiengh 19 2i 7 Benzene 0 Mageren Wavelongh 0 Propyi Benzene 0 017 Ht Datance Threthobt 7 aw _ Display B Apea O Spectium Rateinn ri umy ax O anmy Hasnlina 279 Iris HPLC Spectral Processing Software 280 Chromatogram Pane When a chromatogram is selected on the Data Tree this pane displays the selected chromatogram If the selected chromatogram has no component list then the upper right hand corner of the Chromatogram pane displays the text Selected chromatogram has no component list Otherwise the peaks that have been identified as a result of this operation are labeled with the component name that matched a named spectrum in the library ies As different chromatograms are selected the chromatogram component list and result graph are updated 5 kad 2 a amp Chapter 8 Performing Operations on Chromatograms e Parameters Pane The Parameters pane displays t
111. bance Threshold above the system noise then you may want to modify the Minimum Data Points parameter to ensure that there are sufficient points for a valid calculation to be performed 3 Use the spin box for the Maximum Data Points parameter to specify the minimum number of data points to be found for the result to be valid To return to automatically calculating the minimum absorbance value gt Select the Auto radio button if you wish to have IRIS automatically calculate the minimum absorbance value that can be used in the calculation The Peak Purity value labels are updated for every peak in the chromatogram To add the displayed spectra in the results pane to the Data Tree gt Select Actions gt Add All to View A dialogue box is be displayed with the message The data was added successfully On re displaying the Main or Chrom Spectra views the added spectra will apear in the Data Tree 212 Chapter 8 Performing Operations on Chromatograms To save the results and parameters used in the calculation Once you are satisfied with the purity results you can save the updated purity values and the parameters used in the calculation by selecting File gt Save Results Once you have saved the updated purity values they can be included in a TotalChrom report 1 Select File gt Save Results A save dialog appears that asks you to confirm whether or not you want to save the new values to the chromatogram s result fi
112. be searched when you are trying to match an unknown you can match an unknown spectra by accessing the Library Match Operation page It also decreases the risk of false matches because the search can be restricted to the most likely class of compounds If no matches are found it is always possible to widen the search by adding other libraries to the search list You can also create a spectral library automatically with the apex spectra from named peaks in a chromatogram using the Add Apexes command for more information on using the Add Apexes command see page 153 There are three steps involved in creating a new library 1 Select Tools gt Build Library gt Create The New Library Dialog appears and from this dialog you specify a name for the library as well as select a location where the library will be saved 2 Once you have specified a library name and location where the library will be saved click Save The Create Library dialog appears This dialog is used to specify the Library Minimum and Maximum Wavelengths 3 From the Create Library dialog make sure that the Library Minimum and Maximum Wavelengths values cover the range of the spectra collected For example specify a range of 190 400 for UV only data or specify 400 700 for visible only data or 190 700 for UV and visible data Once you have specified the Library Minimum and Maximum Wavelengths the Edit Library dialog appears At this point the new library has been c
113. box and clicking actives the range box When activated e Handles are displayed on the left and right edges of the box e Positioning the mouse pointer over the left or right handles of the box changes it to a horizontal two headed arrow and click and hold enables the edge to be stretched Upon releasing the mouse the range box is deactivated e Positioning the mouse pointer over the left or right edge of the box except for the position of the handles changes it to a four headed arrow and click and hold enables the complete box to be moved Upon releasing the mouse the range box is deactivated e Positioning the mouse pointer within the box and double clicking loads all the spectra enclosed by the box into the Data Tree and sets them as checked When you release the mouse the range box is cleared Note If more than 70 spectra are included in the range you will be informed of the number of spectra you have requested and are warned that the operation may take some time e Clicking on the chromatogram in an area outside of the box clears the range box 84 Chapter 4 Viewing Spectra Viewing Individual Previously Stored Spectra You can save individual spectrums plus its baseline spectrum for comparison purposes by first extracting the spectrum from a chromatogram Once the spectrum is extracted and appears on the Data Tree you select the spectrum on the Data Tree right mouse click on the spectrum and select Save As A Save Spec
114. checked items are not displayed The following items are available for selection on the Display List Apex Check this option to display the apex spectrum for the selected peak Wavelength Maximum When Apex is checked you can check Wavelength Maximum to have the Apex spectrum annotated with the position and absorbance of the wavelength maximum Baseline Check this option to display the baseline spectrum associated with the peak that is currently selected E Wavelength Maximan Note You can select Actions gt Add All to View to add all selected spectra in the Display List to the Data Tree 231 Iris HPLC Spectral Processing Software Results Pane This pane displays a graphical representation of the items that are checked on the Display List In addition when a peak is selected on the chromatogram this pane displays the Wavelength Maximum value for the selected peak in the upper right hand corner as WMAX Ongolay Note Whenever you select a different peak change the parameters for the operation or select deselect an item on the Display List the Results pane is automatically updated to reflect the change 232 Chapter 8 Performing Operations on Chromatograms How do modify the parameters used that are used to determine the Wavelength Maximum values The Parameters pane displays the values that are currently used in the operation At any time you can optimize adjust the parameters that are li
115. chromatogram name listed on the Data Tree 58 If you are looking at a View where multiple chromatograms can be displayed and the Chromatogram pane is set to a Stacked display the newly opened chromatogram appears at the top of the Chromatogram pane this is the reverse order of how chromatograms are listed on the Data Tree The Contour Map and 3D plot for the newly opened chromatogram are displayed in the same position as shown on the Chromatogram pane Chapter 3 Opening and Viewing Chromatograms Viewing Chromatograms In the previous section you learned how to open chromatograms and select which chromatograms on the Data Tree you want displayed in the current View The following section shows you how to work with chromatograms that are displayed on the Chromatogram pane This section does not cover viewing chromatograms on a Contour Map or 3D Plot For more information on working with Contour Maps and 3D plots refer to The Contour Map View on page 122and The Spectra 3D View on page 132 Working with the Chromatogram pane To work with the Chromatogram pane you must first select the pane by clicking anywhere inside the plot region of the pane When the Chromatogram Pane is selected the border of the pane turns blue wo a iv 1 4 2 2 3 3 4 4 5 5 6 6 Bt 3 8 Figure 3 3 A blue border appears around the Chromatogram pane to indicate that it is selected 59 Iris HPLC Spectral Processing Software Once you have sele
116. chromatograms between the two applications For example if you re looking at a chromatogram in TotalChrom s Reprocess and you wish to examine the same chromatogram in IRIS all you need to do is select Spectra from the Other menu and the chromatogram is displayed in IRIS On the other hand if you are looking at a chromatogram in IRIS you can move that chromatogram to one of two TotalChrom environments Reprocess or Graphic Method Edit To pass a chromatogram from IRIS to TotalChrom all you need to do is right mouse click on the chromatogram in the IRIS Data Tree and select TotalChrom gt Reprocess or Graphic Method Edit from the context menu that appears e Save the results of any arithmetic operations and or chromatographic extractions that were performed in IRIS back in the TotalChrom result file These results can then be included in a printed TotalChrom report e Run the AutoCalc user program which is shipped with your IRIS spectral processing software during a TotalChrom sequence to automatically perform any combination of the arithmetic operations provided by IRIS such as Peak Purity and Spectral Standard Confirmation As part of either a real time or reprocessed sequence the results of these automated operations are automatically saved to the TotalChrom Result file RST and can automatically be included in a TotalChrom report Note This program also allows the automated extraction of up to 8 chromatograms and printing of chro
117. cted the Chromatogram pane you can do the following If the Cursor command appears checked on the View menu you can click anywhere on the displayed chromatogram and cross hairs appear at the point in the chromatogram region where you clicked the cursor The exact positions of the X and Y axes are also displayed as text boxes on the axes On any Chromatogram pane when you move the mouse pointer close to any edge of the plot region the pointer changes into a four headed arrow J ASA A drag operation when the mouse pointer is in this form drags the graph around the plot region On the Main View Chrom Spectra and Compare Views the Stack Overlay command can be used to display chromatograms as either stacked or overlaid If the Chromatogram pane is stacked as indicated when the stacked icon appears to San be pressed down l a separate scale is shown for each curve An If overlaid display is selected as indicated when the stack overlay icon appears A and all plots are plotted on the same Y scale then a single Y scale is shown If each plot is plotted with its own Y scale then the Y axis has no labels The toolbar buttons along the upper right hand side of the window allow you to zoom in on portions of the displayed data and to re scale the data i a 20 woe Ut Ue Ua ee SJL EZLIX For more information on scaling chromatograms see Scaling Chromatograms on page 66 60 Chapter 3 Opening and Viewing Chromatogr
118. ctra contour maps and 3D plots 107 Iris HPLC Spectral Processing Software The Main View consists of the following areas Views Tree The Views Tree provides you access to the Main View selected by default when IRIS is launched in View The Main View is L Iris Fie Ei View Actors Took Hee 2i2 alelaigl2inial gt Heljo aylar oO ESSENSEN a Main View Chromatograms Peo ret oe ey Cee eS eig tt 22 33 44 66 O 77 99 bo 3 512 Erap 4 here butyl berzes o pa Cj i i f i a N eaaae TETTET st wreennnnn 108 Chapter 5 Viewing the Data e Data Tree The Data Tree displays a list of currently loaded chromatograms and spectra You use the Data Tree to select the chromatograms and spectra that you want to see in the relevant panes chromatograms are displayed in the Chromatogram pane Contour Map pane and 3D Spectra pane while spectra are displayed in the Spectra pane Items that appear checked on the Data Tree are displayed while unchecked items on the Data Tree are not displayed Note When you extract spectra from a chromatogram the extracted spectra are listed on the Data Tree under the parent chromatogram Meanwhile previously stored individual spectrum files that you have opened by selecting File gt Open gt Spectrum appear as individual branches on the Data Tree 109 Iris HPLC Spectral Processing Software e Chromatogram Pane The Chromatogram p
119. ctral Method with the new parameters Note For more information on saving the results of a chromatographic operation refer to page 309 It is important to note that all chromatograms that are opened in IRIS which have been processed by the same TotalChrom method share the same Process Spectral Method Therefore once this method is initially created its parameter values are then used to set the parameter values in the Chromatogram s Spectral Method for new chromatogram you open in IRIS which has been processed by the same TotalChrom Method In addition the parameter values stored in a Process Spectral Method can be used by AutoCalc during a TotalChrom sequence to automatically perform any of the arithmetic operations and chromatographic extractions provided by IRIS For more information on AutoCalc see page 314 32 Chapter 1 Introduction Viewing a Spectral Method The View Method dialog allows you to view and print in its entirety the parameter values in a spectral method associated with a chromatogram Chromatogram s Spectral Method or a Process Spectral Method In addition the View Method dialog allows you to view the Audit Trail for a spectral method Below is an example of the View Method dialog Method Viewer example 1 identified and well separated tsm General Library Match Spectral Derivative Spectral Math General Details Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard
120. ctrum comparison If Match retention time window is not checked the comparison is made with all spectra in the library 177 Chapter 7 Performing Operations on Spectra Chapter 7 Performing Operations on Spectra Spectral Derivative The Spectral Derivative operation is where you calculate the first second third or forth derivative for a selected spectrum This operation provides you with the ability to enhance subtle differences of the shape of the spectrum and therefore provide you with more accurate comparisons In fact second order derivative spectra are very useful when the native UV Vis spectrum is not very indicative and does not show sharp maximum of minimum Note The spectrum you select from the operation should be intense and noise free Taking the derivative of a noisy spectrum multiplies variance due to the noise and can result in inaccurate data In this section you will learn how to use the Spectral Derivative operation to provide more specific details of the spectra gt You can access this operation from the Views tree by selecting Operations gt Spectral Derivative n order to calculate spectral derivatives you must select a spectrum from the Data Tree Derivative Main View Chrom Spectra Minimum Wavelength Contour Map 190 5 Spectra3D Compare Operations Library Match 400 Spectral Deriv Spectral Math IV Baseline Corrected Peak Purity ov i Maximum Wavelength exam
121. ctrum from that point As you continue to float your mouse pointer over the 3D plot the Chromatogram and Spectra panes automatically update so that the chromatogram and spectrum from the current location of your mouse pointer are displayed in the relevant panes Note The horizontal cursor on the 3D Plot indicates exactly where you are viewing the chromatogram 4 If you see a chromatogram spectrum that you want extract while you are floating your mouse pointer over the 3D plot just double click The chromatogram and spectrum at the wavelength and time you clicked are displayed in their respective panes Please note that chromatograms are only temporarily displayed and will be cleared when you change the view On the other hand the spectra that are displayed on the view are extracted and therefore added to the Data Tree However you wont see the extracted spectra listed on the Data Tree until you select another View such as the Main View or Chrom Spectra View 139 Iris HPLC Spectral Processing Software How do rotate the display You can rotate the 3D Plot around one axis at a time to identify chromatographic or spectral characteristics more accurately To rotate the 3D plot you must first select the axis that you wish to rotate the 3D plot around you can then use the Rotation slider to rotate the 3D Plot a set number of degrees around the selected axis To rotate the 3D Display 1 3 140 First select th
122. culated by dividing the two spectra and then dividing the maximum value in the resulting plot by the minimum value If the two spectra are identical this quotient the Absorbance Index is 1 00 An Al value above 1 00 implies that the two spectra are different however because of noise and other variables two spectra are usually considered to match well if the Al value is between 1 00 to 1 50 this same test is used in the Peak Purity calculation gt To access this operation expand the Operations node on the Views tree and select Spectral Standard Confirmation To perform this operation you must have a sample chromatogram selected from the Data Tree as well as have specified a standard chromatogram If this is the first time you are performing Spectral Standard Confirmation on a chromatogram IRIS automatically prompts you to select a Standard Chromatogram upon accessing this operation The sample chromatogram is displayed in the upper pane and standard chromatogram is displayed directly below the sample chromatogram alela olalala Mlal folala melle o e Fal ENARA CAAA A Bie Eej Spectral Standard Confirmation Sample Vi baiti Spectral Standard Confirmation amp Operations Library Match Minimum Wavelength Spectral Derivative 23 a Spectral Math z Peak Purity j Absorbance Ratio Maximum Wavelength Wavelength Maximum _ 44 22 33 44 55 66 77 88 a9 400 Spectral Standard Confir Spectral Library Con
123. d in the appropriate pane 4 If you see a chromatogram that you want to temporarily capture just double click on that area in the contour map and the chromatogram from the location you clicked appears in the Chromatogram pane Note Chromatograms that are captured from a Contour Map are only temporary and will be cleared when you select a different view 118 Chapter 5 Viewing the Data How do I temporarily capture a chromatogram from the 3D Plot pane On the Main View you can temporarily capture chromatograms from a 3D Plot However it is important to note that any chromatograms you capture from the 3D Plot pane are temporary and will be cleared from the display when you select a different view Note To temporarily capture a chromatogram from a 3D Plot pane the Chromatogram pane must use an overlaid display To temporarily extract and display a chromatogram from a point on the 3D Plot 1 On the Main View check the chromatogram on the Data Tree that you want displayed as the 3D Plot The chromatogram is displayed on the Chromatogram pane Contour Map pane and 3D Plot pane Make sure that the Chromatogram pane uses an overlaid display Float your mouse pointer over a point on the 3D Plot to temporarily view in the Chromatogram pane the chromatogram from that point As you continue to float your mouse pointer over the 3D Plot the Chromatogram pane automatically updates so that the chromatogram from the current loca
124. d on the Hits Pane Note At any time you can select a different spectrum from the Data Tree that you want to identify 174 Chapter 6 Spectral Libraries To modify the wavelength range used to perform the Library Match gt Enter a new Minimum Wavelength and Maximum Wavelength in the corresponding spin boxes To restrict the search to spectra from peaks with similar retention times 1 Check the Match retention time check box A spin box is enabled 2 From the spin box enter a percentage window for the retention time match 5 tee To examine the effect of using baseline corrected spectra on the Library Match gt Check the Baseline corrected check box to use baseline corrected spectra for the match To add the displayed spectra in the Hits pane to the Data Tree 1 Check the items on the Hits List that you wish to add to the Data Tree 2 Select Actions gt Add All to View A dialogue box is displayed with the message The data was added successfully The selected spectra now appear in the Data Tree and are labelled with the Hit Quality and component name Note Whenever you have modified the Parameters or selected a different spectrum on the Data Tree the match is re run and the Hit List and Hits Pane are updated 175 Iris HPLC Spectral Processing Software To build or modify the list of libraries to be searched Note The list you build is remembered by the system and will be used on subs
125. de a spectrum in the Library List eee 166 How do replace a spectrum in the Library List with one of the Current Spectra ccccceeeeeeseeetteeeeeeeeeeees 167 Identifying a Spectrum using Library Match ccccsceseeeeeeeeeeeeeeeeseeees 168 Tell me about the Library Match operation cceeeeeeeeeeeeeeeeees 168 Summary of Operation Library Match ccccccssesecesseeseeeeeeeeeeeeees 174 How do specify search paraMeters cccceccssesseeeeeeseeeeeaeneeeseees 177 Chapter 7 Performing Operations on Spectra s cseeseeeeee 178 Spectral Derivative ss cft ccccnetesetavivsivecaivades coahivearda saved soa TAIE CA 179 Tell me about the Spectral Derivatives operation cee 180 Summary of Operation Spectral Derivitives cccccsseseecesseeeeeeees 186 Spectral Matheis nmana aea aA ei adanan 187 Tell me about the Spectral Math operation n se 187 Summary of Operation Spectral Math ccccccesecessseseseesseeeeeeees 197 Chapter 8 Performing Operations on Chromatograms 1000 199 Performing Chromatogram Operations ceeeeeeeeeeeeeeeeteeeeeeeees 200 Peak PUTIY a naa a lacie verte vole ee a A Malas E 201 Checking the Purity of Chromatographic Peaks cceeeeeeeeeeeee 202 Tell me about the Peak Purity operation s e 203 How do modify the parameters that are used to calculate Peak Purity ce tee e eter eee ttn eeeee tree eene 209 Summary of Ope
126. dentically named spectrum in a spectral library The comparison of the spectra is made by calculating the Euclidean distance For more information on the Euclidean distance algorithm refer to Appendix 1 The numerical result of this comparison is called the Hit Quality and this value can vary between 0 and 1 4 The lower the Hit Quality number the closer the spectra and the better the match For identification purposes in the Spectral Library Confirmation it is recommended that a Hit Quality threshold of 0 01 be used in order to confirm that the component in the sample is the same component as that in the spectral library This low value of 0 01 for the Hit Quality Threshold is used to prevent false matches However it should be noted that you can determine the value that you want to use for the Hit Quality threshold and are not required to use the recommended Hit Quality threshold of 0 01 For information on specifying a Hit Quality Threshold for the operation refer to How do modify the parameters that are used inthe search on page 259 251 Iris HPLC Spectral Processing Software Tell me about the Spectral Library Confirmation operation The Spectral Library Confirmation operation is comprised of the following areas e Views Tree The Views Tree provides you access to the Spectral Library Confirmation operation To access this operation expand the Operations node and click on Spectral Library Confirmation Spectral Randard Contin
127. e 3 On the Print dialog click Selected Pane only The Chromatograms tab page is enabled 4 Click on the Chromatograms tab page The Chromatograms tab page displays Curves As View C Overlaid C Stacked C Separate Plots a Labels As View C Specified From the Chromatograms tab page you can select whether or not you want the chromatograms to be printed as overlaid on one plot stacked on one plot or printed on separate plots You can also specify which label will be displayed on the printed chromatograms The following options are available to you on the Chromatograms tab page Curves From this section you select how chromatograms will be displayed on the print out As View Prints the contents of the current chromatogram pane that is selected on IRIS window e and Data Tree Overlaid Prints the chromatograms which are displayed on the currently selected chromatogram pane using an overlaid display Stacked Prints the chromatograms which are displayed on the currently selected chromatogram pane using a stacked display All of the chromatograms are displayed on one page Separate Plots Prints each chromatogram on a separate plot When this option is selected the per page spin box is enabled and from this spin box you specify the number of individual graphs that will be printed on each page Labels From this section you specify which label will be displayed on the printout As View Prints the labe
128. e In any Operations all the displayed checked hit spectra will be added to the Data tree under the appropriate chromatogram Derivative Spectra will be named with the time of the source spectrum plus the label Derivative and the derivative order Spectra from Math operations will be labeled MATH where will increment to provide a unique name Information on the math spectrum will yield the source chromatograms and spectra and all necessary parameter values They will be shown in the non operation views If the spectrum already exists in the Data tree the spectrum will not be duplicated Individual spectra may be added by context menus in the specific operation Displays a file select to select the library to be displayed followed by the View Library dialog Enabled at all times Displays a file selector either to select the library to be edited or to name the new one followed by the Edit Library dialog Create Displays a file selector titled New Library From the New Library dialog you specify a name and location for the new library Once you specify a new library the Create Library dialog appears Add Apexes Displays a file selector titled New Library From this dialog you specify a name and location for the new library Once you specify a library the Create Library dialog appears This in turn will be followed by the Edit Library dialog The Edit Library dialog shows all the named peaks from the selected chromatog
129. e You can individually scale the absorbance of each spectrum All spectra however share the same wavelength axis so zooming into the wavelength range on one spectrum zooms into that wavelength range for all spectra J 100 You can abort the zoom before step 4 by clicking the left mouse button outside the zoom box To return to a view of the entire trace select Actions gt Autoscale gt X and Y OR 4 Use the Previous Scale command lef which is also located under the Actions menu Chapter 4 Viewing Spectra How do view and change the axis range for spectra 1 You can view and change the axis range for spectra by right mouse clicking on a spectra pane and selecting Format Graphs from the context menu that appears The Format Graphs window appears with the Spectra tab selected This window allows you to set the minimum and maximum values on both the X and Y axes 2 From the Spectra tab page specify the Maximum and Minimum values for the X and Y axes 3 Click OK to apply changes and close the Format Graphs dialog Note Changes in the wavelength range always affect all the spectra 101 Iris HPLC Spectral Processing Software Saving an Individual Spectrum You can use the File gt Save As command to save an individual spectrum plus its baseline spectrum for comparison purposes The spectrum is saved as an UV file You must have the spectrum selected on the Data Tree in order to save it Once you have sa
130. e example 1 identified and wel separated rst 3 696 Path c iris data data data data _ Filename example 1 identified and we separated rst 5 082 Path c iris data data data data a Filename example 1 identified and well separated rst 2 383 Path c iris data data data data Figure 11 2 An example of the first page that is printed when a user selects to print spectra currently displayed on the Chrom Spectra View 328 Chapter 10 Printing and Presentations All subsequent pages include the title of the document being printed the date and time stamp the user name and full name of the person generating the report and the page number in the form of Page X of W Operation Chrom Spectra View Date 07 11 2006 01 03 23 AM Eastern Standard Time User manager Page 2 of 2 Figure 11 3 Example showing the second page of a print out where a user selected to print the contents in the currently selected Spectra pane from the Chrom Spectra View using a Stacked display 329 Iris HPLC Spectral Processing Software Tell me about the Print dialog When you select File gt Print from the IRIS menu bar the Print dialog displays This dialog consists of three tab pages The General tab page is always enabled and from this tab page you can define the printer you want to use as well as the orientation for your print out and define what you want to print If you select Selected Pane only on the General tab page
131. e Results pane 215 Iris HPLC Spectral Processing Software Tell me about the Absorbance Ratio Operation The Absorbance Ratio operation consists of the following areas e Views Tree The Views Tree provides you access to the Absorbance Ratio operation You can access this operation by selecting Operations gt Absorbance Ratio from the Views Tree Spectral Randard Contin Spectral Library Confirme Posk Lbrary Search Retention Time Adjustme Extract Cromatograms i gt 216 Chapter 8 Performing Operations on Chromatograms Data Tree The Data Tree displays a list of currently loaded chromatograms You use the Data Tree to select the chromatograms that you want to use in the operation The chromatogram you select from the Data Tree will is displayed in the upper pane Chromatogram pane for the Operation 217 Iris HPLC Spectral Processing Software e Chromatogram Pane This pane displays the chromatogram that you selected from the Data Tree Fie Edt View Atoni Took tbb 2 3 3 0 a 8 2 0 sJ gt Hesja mewa E D P alel We Wt al leis Belt s Absorbance Ratio S O Opar tors A Library Match A Worslength A Sgacts ad Derteatove os PERTE Spectra Math Pook Party Absorbance Ratio Wavelength Marraga Specia Sanded Contin Spectra Lovary Confirme Pook Library Search Retention Tee Adistre _ Wagelongth B I Baseline Corect Specta Absorbance Threshold Liat Oromefogen w g
132. e X axis since Normalize All evaluates all points in the chromatogram and therefore resets the X axis 70 Chapter 3 Opening and Viewing Chromatograms To normalize both the retention time and absorbance 1 Click anywhere on the chromatogram you want to normalize Click on the Normalize X and Y icon Wie OR Select Actions gt Normalize gt X and Y from the menu bar The retention time axis of the selected chromatogram is scaled to fill the region All other chromatograms will be re scalled to this retention time range The absorbance axis is scaled to fill 80 of the display To normalize along the Y axis only 1 2 Click the region below the point where you wish normalization to occur Click on the Normalize Y icon a OR Select Actions gt Normalize gt Y only from the menu bar The chromatogram will be normalized at the maximum point in the displayed region without changing or resetting the X axis value To normalize to the highest point to the right of the cursor 1 Click the region below the point where you wish normalization to occur Click on the Offset Normalize W icon OR Select Actions gt Normalize gt Offset from the menu bar The chromatogram is normalized to the maximum point above the cursor position To normalize at the position of the cursor 1 Click the region at the point where you wish normalization to occur Click on the Normalize Point icon Lisi OR Select Actions
133. e bottom Spectra Pane the peak maximum of the displayed spectrum is labeled with the wavelength and absorbance Note If you select a different chromatogram the apex optimized chromatogram Is recalculated and re displayed If you change any of the parameters used in this calculation the apex optimized chromatogram is updated 4 You can add result spectra to the Data Tree by checking Apex and or Baseline on the Display List and then selecting Actions gt Add All to view The selected spectra is added to the Data Tree under the parent chromatogram The added spectra is labeled on the data tree with the Retention Time followed by Apex or Baseline To create a TotalChrom chromatogram from the apex optimized chromatogram 1 From the menu bar select File gt Save Results A save dialog appears that asks you to confirm whether or not you want to save the changes to the chromatogram s result file RST and the changes to its associated spectral method files TSM Click Yes If the TotalChrom method is present a result file is generated The apex optimized chromatogram that is generated is named after the original raw file name followed by Apex Optimized plus a time date stamp if the name already exists Note The conditions used to create the chromatogram can only be found on the Apex Optimized Chromatogram View and are not stored with the chromatogram in any way Therefore if you use the Save Results command it
134. e component as in the spectral library You can modify the Hit Distance Threshold value to include or exclude library spectra as a match to a spectrum at the peak apex in the chromatogram For instance to prevent unlikely matches you may wish to set a lower maximum hit threshold 265 Iris HPLC Spectral Processing Software Tell me about the Peak Library Search operation The Peak Library Search operation is comprised of the following areas 266 Views Tree The Views Tree provides you access to the Peak Library Search operation You can access this page by expanding the Operations node and selecting Peak Library Search Eak Spectral Standard Confini Spectral LOcary Confeme Pook Beary Search Retention Time Adjp stme Extract Chromatograms Display S ionooooeos Chapter 8 Performing Operations on Chromatograms e Data Tree The Data tree here shows only a list of chromatograms and is used to select the required chromatogram from the ones available The selected chromatogram is displayed in the top graph Chromatogram pane As different chromatograms are selected the nearest peak is selected the other two graphs are updated and chromatogram labels are updated Display 24 iooooosos 267 Iris 268 HPLC Spectral Processing Software Chromatogram Pane When a chromatogram is selected on the Data Tree the chromatogram is displayed on this pane and the peak maxima are lab
135. e result to be valid If the number of data points calculated is less than the minimum set then the results are considered invalid and the absorbance index result is shown as 0 Pass Threshold Use this spin box to set the maximum value at which the two spectra are considered to match If the two spectra match exactly then the value will be 1 To allow for noise and other errors in the system this value is normally set at 1 5 You can reduce or increase this value to fit your own criteria If the calculated absorbance index result is greater than the threshold set here then the test is failed and the Al result is shown in bold red Baseline correct Check this option to use the baseline corrected spectra in the spectra calculation Standard Click on this button to change the Standard Chromatogram that Chromatogram you want to use for the operation 245 Iris HPLC Spectral Processing Software Absorbance Threshold To ensure that IRIS determines performs Spectral Standard Confirmation on small peaks but does not interpret baseline noise as peaks you can use this parameter to set the minimum absorbance values above the system noise and therefore obtain more reproducible results e When Auto is selected the absorbance threshold values are calculated automatically by the system and are set to either 0 0005 A U or 2 of the maximum absorbance in the spectrum whichever is greater The entry field is greyed when Auto is selected
136. e rotation controls for rotating the 3D plot Click on the Rotate X La icon if you want to rotate the 3D plot around the X axis OR Click on the Rotate Y La if you want to rotate the 3D plot around the Y axis The selected icon appears to be pressed down to indicate that the 3D plot will be roated around the selected axis Use the Rotation slider to rotate the 3D Plot a set number of degrees around the axis you selected in step 1 Move the slide to the right to rotate the plot to the right or the up direction Move the slide to the left to move the plot in the reverse direction Release the slider to return it to the center position Chapter 5 Viewing the Data Scaling a 3D Plot Most of the panning and zooming tools that can be used on other panes are not particularly useful or do not operation on 3D panes Scaling a 3 D Plot view is best done using the Format Graphs command which is located under the Tools menu bar From the Format Graphs dialog you can scale all three axes wavelength retention time and absorbance on the plot as well as select to reverse the wavelength axis to look behind large peaks In addition to using the Format Graphs dialog to scale a 3 D plot you can also use the Autoscale commands to bring all data into view How do specify limits for a 3D plot and reverse the Wavelength Axis The 3D Plot tab on the Format graphs dialog allows you specify limits for all three axes as well as reverse th
137. e the pointer over the edge of the pane that you want to adjust The pointer turns into a line with arrows on each end ls 2 Press the left mouse button and drag up down left or right The pane is resized after you release the mouse button The program maintains these settings until you adjust the panes again 127 Iris HPLC Spectral Processing Software How do I view chromatograms and spectra on the Contour Map View In this section you will learn how to capture and display spectra and chromatograms from a contour map Note A captured spectrum is a spectrum extracted from its source and displayed permanently in the Spectra pane and is listed on the Data Tree A captured spectrum can be hidden and or removed To extract and display a chromatogram and spectrum from a point on the Contour Map 1 From the Views Tree select Contour Map View The Contour Map View displays From the Data Tree click on the chromatogram you want displayed as the contour map Float your mouse pointer over a point on the Contour Map plot to temporarily view in their respective panes the chromatogram and spectrum from that point As you continue to float your mouse pointer over the Contour Map the Chromatogram and Spectra panes automatically update so that the chromatogram and spectrum from the current location of your mouse pointer are displayed in the appropriate panes If you see a chromatogram spectrum that you want extract then
138. e wavelength axis Z axis To specify limits for a 3D plot 1 On the 3D Plot tab of the Format Graphs dialog specify the minimum and maximum values for the X Y and Z axes The six spin boxes on this page represent the minimum and maximum values for the X Y and Z axes When you specify values for the three axes on this dialog you can preview the effect directly on the Format Graphs dialog Format Graphs Chromatogram Spectrum Contour Map amp Limits V Reverse Z axis Colors Background Axes M Apply OK Cancel 2 When you are finished setting the numerical limits for the plot click OK The Format Graphs dialog closes and the selected plot is scaled according to the limits you specified 141 Iris HPLC Spectral Processing Software How do I reverse the wavelength axis of a 3 D Plot To reverse the Wavelength Axis on a 3D plot The 3D Plot tab page on the Format Graphs dialog contains a switch for reversing the wavelength axis Most UV spectra have very high absorbance in the low UV Therefore the 3 D plot is normally displayed reversed i e with the low UV at the back of the display so it does not obscure the information in the mid UV range 220 300 nm The switch is useful if you want to display the low UV at the front or if you want to look behind one of the peaks in the display 1 On the 3D Plot tab page of the Format Graphs dialog click on the Reverse Z Axis check box to preview the ef
139. ectral Derivative The Spectral Derivatives operation is displayed Click on a spectrum listed on the Data Tree The selected sample spectrum is displayed in the Spectrum Pane The spectral derivatives are automatically calculated using the Parameters specified on this operation The Derivatives Pane displays the spectral derivatives that appear checked on the Display List If you wish to change the parameters used to calculate spectral derivatives for the sample spectrum you may do so by modifying the following parameters Select the lower limit of the spectrum range to be included in the calculation from the Minimum Wavelength spin box Select the upper limit of the spectrum range to be included in the calculation from the Maximum Wavelength spin box Check the Baseline corrected check box to use the baseline corrected spectrum for the derivative From the Display List check the spectral derives you wish to be displayed on the Derivatives Graph You can select to display the Sample spectrum the First Derivative Second Derivative Third Derivative and Fourth Derivative The Derivatives Graph updates to display what is checked on the Display List To add result spectrum to the Data Tree gt From the menu bar select Actions gt Add All to View to add all the derivative spectra that appear checked in the Display List to the Data Tree To save a result spectrum to a uv file 11 12 13 186 From the Data Tree
140. ectral method to view and click Open The View Method dialog displays 34 Chapter 1 Introduction Tell me about the View Method dialog The View Method dialog is comprised three main areas e A list box that lists the components of the spectral method file Click on one of the items listed here and the right hand portion of the dialog displays in read only format the parameters for the selected item Methnrd Viewer examnle 1 identified and well separated tsm General Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Printing General Details Section Last Edited Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram 4 9 2006 2 39 43 PM Description Audit Trail 35 Iris HPLC Spectral Processing Software e The Parameters display shows you the parameters and their values for the operation have selected Method Viewer example 1 identified and well separated tsm General Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spect
141. ectrum 104 Peak Start Only This option selects the spectrum at the Baseline Start position before the current chromatographic peak as the baseline spectrum If all peaks are baseline separated each peak in the chromatogram would have a different baseline spectrum This spectrum will be used for baseline correction until the next Baseline Start position For spectra before the first start of the first peak in the chromatogram the first baseline spectrum will be used for all spectra before the first peak For spectra after the first end of the last peak in the chromatogram the last baseline spectrum will be used for all spectra after the last peak Selected Spectrum This option uses a spectrum at a point you select on the chromatogram currently displayed on this dialog as the baseline spectrum When you select this option a vertical marker is displayed on the graph at the start of the chromatogram You then drag the marker to the required position The baseline spectrum will now be the spectrum from this point This marker will be re displayed whenever Spectrum Type is selected as the Peak Label Average of range This option creates the baseline spectrum by averaging the spectra in a range that you select on the chromatogram that is currently displayed on the Spectral Baseline Correction dialog When this option is enabled a square is displayed on the graph that you drag to the required position and resize to select a range of
142. ectrum from the Contour Map pane To extract and display a spectrum from a point on the Contour Map 1 On the Main View check the chromatogram on the Data Tree that you want displayed as a contour map The chromatogram is displayed on the Chromatogram pane Contour Map pane and 3D Plot pane 2 Float your mouse pointer over a point on the contour map plot to temporarily view in the Spectra pane the spectrum from that point As you continue to float your mouse pointer over the contour map the Spectra pane automatically updates so that the spectrum from the current location of your mouse pointer is displayed in the appropriate pane 3 If you see a spectrum that you want extract just double click on that area in the contour map and the spectrum at the wavelength and time you clicked appears in the Spectra pane and is now listed on the Data Tree Note Unlike the Main View where extracted spectra are displayed on the Data Tree when you extract a spectrum from the Contour Map View the spectrum is added to the Data Tree however you will not see the extracted spectrum on the Data Tree until you exit the Contour Map View The reason for this is because on the Contour Map View the Data Tree is used only for selecting the chromatogram that you want displayed You will be able to see all of the spectra you have extracted once you select a different view such as the Main View or the Chrom Spectra View How do I capture a spectrum from the
143. ed chromatogram is labeled with the Component Name of the best match as well as the Hit Quality Value a numerical value that indicates how close a match the currently displayed peak is to the component name from the matching library spectrum the lower the Hit Quality Value the closer the match If IRIS could not find a match for a peak the unmatched peak is labeled with Not Found If you want to evaluate how the best match for a specific peak was calculated then click on that peak In the pane located below the chromatogram plot the apex spectra for the currently selected peak is displayed along with the library spectrum considered to be the best match In addition in the lower right hand corner of the Peak Library Search operation a list of library spectra check boxes is displayed The Library spectra checkboxes are listed by their Hit Quality then by component name the spectra with the lowest Hit Quality number is considered the best match To visually compare how close the apex spectrum of the currently selected peak matches to additional library spectra check the Sample check box and then check any number of library spectra listed on the Hits List that you wish to compare The selected spectra are displayed in the Results pane which is located directly below the Chromatogram pane 264 Chapter 8 Performing Operations on Chromatograms How does IRIS perform a Peak Library Search As stated earlier the Peak Library Search
144. el to a single chromatogram 1 Z Select a view from the Views Tree Click on any area in the white space of a stacked chromatogram display that contains the chromatogram you wish to label A blue border appears around the selected stacked display From the Actions menu select Actions gt Label Chromatograms The Label Chromatograms dialog appears From the Label drop down list select a label you wish to apply to the chromatogram Uncheck Apply to all chromatograms Click OK The label you selected is applied to the chromatogram 65 Iris HPLC Spectral Processing Software Scaling Chromatograms IRIS offers you a variety of options to scale a chromatogram You can Visually specify an area of the display to zoom into using the Box Zoom function Scale chromatograms by specifying the axis range from the Format Graphs dialog Autoscale only the absorbance axis to fit the chromatogram between 10 and 90 of the display or you can scale both axes to display the full retention time range and re scale the absorbance to fit between 10 and 90 of the display Zoom in a continuous fashion Normalize an entire chromatogram using the Normalize X and Y command Wie i e all points in the displayed chromatogram normalize along the Y axis only using the Normalize Y command i normalize at the current cursor position using the Normalize Point command Lisi or you can normalize to the maximum absorbance value to the right
145. elled with the top library hit name as calculated by the current settings or with Wot found when IRIS was unable to find a match for the peak The labels are automatically updated with every change in parameters When a chromatogram is loaded or changed these labels are calculated and displayed as soon as possible ER iooooosos Chapter 8 Performing Operations on Chromatograms Parameters Pane From this pane you can change the minimum and maximum wavelengths to be used for the search you can also change the Hit Threshold value which defines whether a valid match has been found and you can specify whether retention time is to be used to restrict the search as well as whether or not you wish to use baseline corrected spectra for the library match 269 Iris 270 HPLC Spectral Processing Software Hits List The Hits List contains a list of check boxes for selecting what is displayed on the Results Pane Items that appear checked on this list are displayed in the Results pane unchecked items are not displayed in the Results pane The first item in the list labeled Sample is the apex spectrum of the currently selected peak You can check this item to compare how close the apex spectrum of the currently selected peak matches any of the library spectra that are listed here as hits The remaining items that appear on this list are the hits from the library match listed in hit order with the best hit firs
146. ention time and absorbance 1 2 68 Click on the Chromatogram you wish to autoscale in the X and Y directions Select Actions gt Autoscale gt X and Y OR Click on the Autoscale X and Y icon aS The retention time axis of the selected chromatogram is scaled to fill the region All other chromatograms will be re scalled to this retention time range The absorbance axis is scaled to fill 80 of the display Chapter 3 Opening and Viewing Chromatograms How do I zoom ina continuous fashion FASETTEN AG J LEZ 12 You can zoom a chromatogram in a continuous fashion using the slider zoom feature in conjunction with the Zoom X lt 8 and Zoom Y icons The slider zoom enables you to expand or contract the chromatogram in a continuous manner The Zoom X and Zoom Y commands determine what is zoomed when you are interacting with the zoom slider To continuously zoom a chromatogram 1 Before performing the zoom place the cursor at the position that you want to zoom since the zoom is around the position of the cross hair cursor 2 Click on the Zoom X axis icon and or the Zoom Y axis icon on the Toolbar to set the required zoom mode You can select both the X and Y axis icons to create an X and Y zoom The buttons appear depressed when active m 3 Push the Toolbar slider to the right or left 69 Iris HPLC Spectral Processing Software How do I use the use the Normalization commands to find subtle differenc
147. eport consisted of four pages The first page contained a color coded key identifying each spectrum in the print out The second and third pages contained two spectra per page and the last page contained the firth spectrum that we selected to print Operation ChromySeectra View gt Date 07 13 2006 12 57 19 PM Eastern Standard Time Perkin imor User manager SEN Page 2a RE iat E R S a E L eid R R a beet te E 339 Iris HPLC Spectral Processing Software How do I print the current view or operation If you want to print the contents of the current view or operation You can select to print the contents of the current IRIS window except for the Views Tree and Data Tree by doing the following 1 From the current view operation select File gt Print The Print dialog displays General l Printer Adobe PDF 7 Preferences Orientation Portrait C Landscape Print What All Panes In View Selected Pane Only C Apex Spectra Cancel 2 Under the Printer drop down menu select a printer 3 Click on the Preferences button to define the settings for the printer 4 Select the Orientation for the print out as either Portrait or Landscape 5 Select All Panes in View to print the contents of the current IRIS window expect for the Views Tree and Data Tree Note Ifyou are printing the display from an operation the only option that is enabled is All Panes in View 6 Click Print when y
148. equent searches unless you modify the list of selected libraries to be searched 1 176 From the Library Match operation click on the Library List button The Libraries List dialog appears Specify the directory path where the libraries you wish to search are located by typing the directory path in the Look in text box or by clicking on the Browse button and selecting a directory path from the Browse for Directory dialog box Once you have specified a directory path a list of libraries available for selection appears on the Libraries list dialog From the Available libraries list click on the libraries you wish to search and then click on the Add button You can either click on a single library to add it to the Libraries list or you can select multiple libraries to add to the Libraries List by using CTRL click or SHIFT click The selected libraries now appear in the Libraries List To remove a library from the Libraries list click on the library and then click Delete The selected library is removed from the Libraries list and reappears in the Available Libraries list You can view a description of a library by clicking on the library from either list The Description of the selected library appears below the list boxes Click OK You are returned to the Library Match operation and the results your search are displayed in the Hits Pane Chapter 6 Spectral Libraries How do I specify search parameters The Par
149. er you release the mouse button The program maintains these settings until you adjust the panes again How do open and display chromatograms You can open chromatograms using the File gt Open gt Chromatogram command on the menu bar To display chromatograms on the Main View check the chromatograms you wish to be displayed from the Data Tree To open a chromatogram 1 From the menu bar select File gt Open gt Chromatogram The Open Chromatogram dialog appears 2 Select the result file RST that you want to look at and click Open The Open dialog closes and the name of the chromatogram is added to the Data Tree and the chromatogram is displayed in the Chromatogram pane The chromatogram can be hidden by unchecking it from the Data Tree Note You can find information on a chromatogram before it is opened by selecting the Information command in the File menu and then selecting the chromatogram you wish to view more information on from the Open Chromatogram dialog that appears 114 Chapter 5 Viewing the Data How do I open a previously stored individual spectrum You can open previously stored individual spectrum files using the File gt Open gt Spectrum command You can also select the spectra that you wish to be displayed on this window by checking the spectra you want to display on the Data Tree To open previously stored individual spectrum files 1 From the menu bar select File gt Open gt Spectru
150. es between chromatographic peaks The Normalization commands are most useful when multiple overlaid chromatograms are displayed and you want to find subtle differences in the plot Basically the Normalize commands help you compare the exact shapes of peaks by converting all of the displayed peaks to the same maximum height One example in which the normalize commands may prove useful is if you have multiple overlaid chromatograms displayed on your screen and you want to confirm the presence of closely co eluting components You can select pane containing the multiple overlaid chromatograms and then use the normalize commands described below to better qualitatively compare the exact shapes of the peaks For a detailed description of how the Normalization commands can be used refer to the section titled Detailed Description of Normalization command s in Chapter 4 Viewing Spectra The Normalization commands are as follows Icon Associated menu Description command hie Normalize X and Y Normalizes the graph so all plots are full scale W Normalize Y only Normalizes the graph so all plots are full scale without changing the X axis Lv Offset Normalize Normalizes all plots to the highest point to the right of the cursor position RA Normalize Point Normalizes all plots at the cursor position Note The Normalize Y command is useful if you have zoomed in on a specific region of the chromatogram and want to normalize without resetting th
151. ess Spectral Method that can be used by AutoCalc during a running sequence Note For more information on Spectral Methods see the section titled About Spectral Methods on page 28 For more information on arithmetic operations an chromatographic extractions refer to Chapter 8 Performing Operations on Chromatograms 315 Iris HPLC Spectral Processing Software Before specifying which operations you want to be performed you must do the following 1 In IRIS open a chromatogram that has been processed with the same TC method that will be used to run or reprocess the sequence Next verify the name of the chromatogram s associated TC method To do this first right mouse click on the chromatogram in the IRIS Data Tree and select Information from the context menu that appears A Chromatogram Information dialog appears that shows the TC method associated with the selected chromatogram Note this method name Now exit the Chromatogram Information dialog box From the IRIS menu bar select File gt Open gt Method and open the spectral method having the same name and file location as the TC method just noted The View Method dialog appears This dialog allows you to view the parameters for the method you just opened In the opened Method Viewer review the spectral method s individual parameters by selecting all the desired operation s from the list at left Once you have reviewed the parameters of the spectral method
152. ess you must first save the result file In addition you must save the result file after you make any change in Reprocess and upon entry into Reprocess since TotalChrom s Reprocess always reprocesses the data upon entry and the results obtained may differ from the results in the saved rst file Any chromatogram you can view in TotalChrom can be opened quickly and easily in IRIS with no need to select the chromatogram again within IRIS The file you were viewing in TotalChrom appears in the chromatogram region of the IRIS Main View gt If you re looking at a chromatogram in TotalChrom s Reprocess and you wish to examine the same chromatogram in IRIS select Spectra from the Other menu Note The Spectra command is active only if there are spectra associated with the chromatogram you are currently viewing You are moved directly into IRIS and the chromatogram is selected on the IRIS Data Tree and displayed on the Main View Chapter 1 Introduction Overview of the IRIS User Interface IRIS is designed so that you can easily process manipulate and display spectral data associated with chromatograms from one main window Following is a high level look at the IRIS user interface SE slslglolalale mafe Helea lF e Fe Fal SL wae Ua wea Ua wal es AA E leei Main View Chrom Spectra Contour Map Spectra3sD Compare Operations Custom Views vn wa wa wapa aoa a on po a va oa waa ae ya w wo ay wawa waapa w
153. esults Pane This pane displays a graphical representation of the items that are checked on the Display List In addition in the right hand corner of this pane the Purity Index for currently selected peak is displayed If the peak s purity value exceeds the Purity Limit currently defined on the Parameters pane then the Purity Index is shown in red If the peak s purity value is less than or equal to the currently defined Purity Limit then the Purity Index is shown in blue Note Whenever you select a different peak change the parameters for the operation or select deselect an item on the Display List the Result pane is automatically updated to reflect the change 208 Chapter 8 Performing Operations on Chromatograms How do modify the parameters that are used to calculate Peak Purity The Parameters pane is where you set and investigate the various parameters for calculating Peak Purity At any time you can optimize adjust the parameters that are listed on the Peak Purity operation and the Peak Purity value labels are updated for every peak in the chromatogram Below is a list of the parameters you can modify Parameter Minimum Wavelength Maximum Wavelength Minimum Data Points Baseline Correct Spectra Purity Limit Description This parameter allows you to set the lower limit of the spectrum range to be included in calculation This parameter allows you to set the upper limit of the spectrum range
154. ete separation of Butyl Benzene and Anthracene Example 2 identified but with coelution A Example 1 identified and well separated Example 2 Identified Incomplete separation of Butyl Benzene and Anthracene By Example 4 Butyl Benzene and Anthracene co elute By Example 3 Butyl Benzene and Anthracene poorly separated A Example 1 Benzene to Anthracene Identified Well Separated By Example 3 Identified Butyl Benzene and Anthracene poorly separated By Example 4 Identified Butyl Benzene and Anthracene co elute My Documents My Computer i hile File name Example 2 Identified Incomplete separation o Y aces Files of type TotalChrom ES Result File rst Cancel 2 From the Open Chromatogram dialog select the result file RST that you want to view information on and then click Open The Information dialog box for the selected chromatogram appears 63 Iris HPLC Spectral Processing Software To obtain information about a chromatogram that is listed in the Data Tree gt From the Data Tree right mouse click on a chromatogram and select Information from the context menu that appears The Information dialog box for the selected chromatogram appears Chromatogram Information Result File c program files perkinelmer instruments iris dataexample 2 identi Number of Peaks c program files perkinelmer instruments iris data Example _coelutic c program files perkinelmer in
155. fect Format Graphs Limits V Reverse Z axis 190 m 0 0076 Colors Background Apply OK Cancel The check mark is cleared or returned depending on its previous state When this option appears checked the 3D plot is displayed reversed 2 Click OK The Format Graphs dialog closes and the plot is redrawn with wavelength axis reversed from its previous state 142 Chapter 5 Viewing the Data How do I use the Autoscale commands to scale a 3D Plot The Autoscale X and Y and Autoscale Y only commands can be used on any plot region to bring all the data into view Autoscale Y only can be used after a change on the wavelength and or time axis to re scale the absorbance range only Autoscale X and Y can be used to return to the full display of the plot However since the initial scaling for the 3D Plots and Contour Maps is based on the scaling in the previous view the Autoscale commands will not necessarily return them to their initial states To autoscale the absorbance without changing the wavelength or time axes Use this command to scale the absorbance range after a change on the wavelength and or time axis 1 Click anywhere on the region to be re scaled 2 Click on the Autoscale Y icon The Absorbance axis is automatically scaled to fill 80 of the display region To return to the full display of the plot Use this command to return to the full display of the plot 1 Click anywhere on the
156. file name and path for the library spectrum that has the same name as the peak selected on the chromatogram is displayed here You can right mouse click on this section and select Properties from the context menu that appears to view detailed information on the library spectrum such as the source the chromatogram and retention the baseline and who added the spectrum and when 256 Chapter 8 Performing Operations on Chromatograms Display List You use the Display List to select the information you want displayed on the Results pane When items appear checked on this list they are displayed in the Results Pane Meanwhile unchecked items are not displayed The following items are available for selection on the Display List Apex Check this item to display the apex spectrum from the chromatogram on the Results pane Library Check this item to display the matching named spectrum from the library on the Result pane Spectrum baseline Check this item to display the baseline spectrum used for the apex spectrum on the Results pane Library baseline Check this item to display the baseline spectrum used for the library spectrum on the Results pane 7 257 Iris HPLC Spectral Processing Software e Results Pane This pane displays a graphical representation of the items that are checked on the Display List Spectra Randard Contin Spectral Ltn ary Confeme Posh Ubrary Search Retention Te
157. file name of the chromatogram you just opened is listed at the bottom of the Data Tree Depending upon the View you have selected you can specify whether or not a chromatogram is displayed on the view by doing the following To have the chromatogram displayed on the current view check the chromatogram on the Data Tree OR If the current view only allows one chromatogram to be displayed on the View you can select which chromatogram you want displayed on the view by selecting it on the Data Tree For example on the Main View each chromatogram that appears checked on the Data Tree is displayed on the Chromatogram pane on the Contour Map pane and the 3D Plot pane DER File Edit View Actions Tools Help e 4 S My fecal tet OFS O Kramule lal Main View Chromatograms Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views t example 1 identified and well seq WM example 2 identified but with coe umun yoana ana TL TLD TL TL CT CO KT aja Hes bed ed ke abel EL echo he bald bed og el doh 0 511 522 533 544 555 566 577 588 59 COOOL FO LELEN TEELT IT MO TELIT 200 225 250 275 300 325 350 375 400 Loginimanager amp Figure 3 2 The Main View with multiple chromatograms displayed Note In order for you to easily identify the newly opened chromatogram please note that the chromatogram graph is color coded to match the
158. finished entering the required information on the Audit Trail dialog The Electronic Signature dialog appears 9 From the Electronic Signature dialog enter your User Name and Password and click OK The Electronic Signature dialog closes and the Edit Library dialog appears On the Edit Library dialog all the named peaks from the selected chromatogram are displayed in the Library list Note The components that appear in the Library list are named from the component names in the result file 155 Iris HPLC Spectral Processing Software Edit Library Library Details Name library alb Description Minimum Wavelength Maximum Wavelength 190 400 Spectr Current Spectra Library i Benzene Toluene Ethyl Benzene Propyl Benzene Butyl Benzene 2 13 Downslope Anthracene 2 13 Purity Result Replace 220 275 330 385 M Show baseline corrected spectrum Show baseline spectrum Audit Trail OK Cancel 10 For more information on using the Edit Library dialog see Editing a Library on page 162 OR Click OK to exit the Edit Library dialog 156 Chapter 6 Spectral Libraries Manually Creating a Library The Create Library Command found under the Tools menu by selecting Tools gt Build Library gt Create allows you to create new libraries You may find this function useful for creating a library for each general class of compound that you work with This reduces the number of spectra that must
159. firmation 710 Spectral Library Confirmation 7 Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Printing Derivative V Baseline Corrected Audit Trail e f you select General from the list box the right hand portion of the dialog lists the date and time when each section of the spectral method was last edited e f you select an operation such as Absorbance Ratio from the list box the right hand portion of the dialog displays the parameter values that are used to calculate the results for that operation e f you select any of the items listed under the Printing node the right hand portion of the dialog displays the default print settings for the spectral method e A Print button that you can select to print a report of the entire spectral method details e An Audit Trail button that you can select to view the audit trail for the spectral method The Audit Trail can also be printed e An Exit button that you select to close the dialog 40 Chapter 1 Introduction How do edit the default method To edit the Default Method 1 From the IRIS menu bar select Tools gt Edit Default Method The Edit Method dialog appears 2 From the list box select the operation that you wish to modify 3 The parameters for the selected operation are displayed on the right hand side of the dialog 4 When you have finished modifying parameters click Save
160. firme Peak Library Search 5 4 denpa butyl benzene and anthracene co elute oe Data Ports 3 c C Retention Time Adjustme E D 7 Extract Chromatograms s z Pass Threshold 1 5 5 o a COO Ce DD example1_well_separated001 ge Ta 88 99 V Baseline Corect Spectra example 4 identified butyl beg ig Standard Chromatogram Threshold for Sample Threshold for Standard Auto Manual Auto Manual Saf Display eS a eee O Sample Baseline 220 275 330 385 O Standard Baseline Login manager amp 4 Figure 8 4 The Spectral Standard Confirmation 236 Chapter 8 Performing Operations on Chromatograms Verifying the Identity of Chromatographic Peaks by Comparing to a Standard Chromatogram Because Spectral Standard Confirmation identifies the corresponding peak in the standard chromatograms by its component name this function applies only to named peaks If the chromatograms were run using different TotalChrom methods peak names may not exactly match IRIS warns you when this is the case If you apply the Spectral Standard Confirmation function to a chromatogram with no identified peaks an error message is displayed and you will not be able to confirm the identity of any peaks until you select a new chromatogram that has identified peaks It should also be noted that the Spectral Standard Confirmation operation ignores any unnamed peaks in the chromatogram as well as ignores named peaks i
161. first select a chromatogram that is listed on the Data Tree The selected chromatogram is displayed on the view in the upper graph Chromatogram pane and each peak in the chromatogram is labeled with a Wavelength Maximum value IRIS determines the wavelength maximum values using the parameter values that are currently displayed on the page You can modify the calculation parameters at any time and IRIS automatically recalculates and displays the new values on the page If you are interested in the wavelength maximum of a specific peak click on the peak and in the bottom graph Results pane the apex and baseline spectra for the peak are displayed The apex spectra are annotated with the position and the absorbance of the wavelength maximum In addition in the right hand corner of the Results pane the Wavelength Maximum value for the selected peak is displayed Note Use the Display List to specify what is displayed on the Results pane Items that appear checked on the Display List are plotted on the Results pane 226 Chapter 8 Performing Operations on Chromatograms Tell me about the Wavelength Maximum operation The Wavelength Maximum operation is comprised of the following areas e Views Tree The Views Tree provides you access to the Wavelength Maximum operation To access this operation expand the Operations node and click on Wavelength Maximum 227 Iris 228 HPLC Spectral Processing Software Data Tree The Data
162. g to a Spectral Library ccccccseeeseceeeeeeeeeeseneeeeeseaes 251 Tell me about the Spectral Library Confirmation operation 252 How do modify the parameters that are used in the search 259 Summary of Operation Spectral Library Confirmation 000 260 Peak Library Search cceceeceteeeststete eee ee tees eae ete eeeeeeeeeanaaateetereeeeeaaaaa 263 Identifying Chromatographic Peaks 264 Tell me about the Peak Library Search operation 266 How do modify the parameters used in the search secc 272 Summary of Operation Peak Library Search 273 Retention Time Adjustment 0 0 2 eee tee teeter ee ae tte eeteeeeeeeeead 276 When should use this operation ceee 277 Assigning a Component Name to a Peak and Correcting the Retention Time in the Chromatogram s Result File 277 Tell me about the Retention Time Adjustment operation 278 How do modify the parameters that are used in the spectral matching etree eter reer ea aaneeees 286 Summary of Operation Retention Time Adjustment 287 Extract Chromatograms ieena a teeter A R Raa adea 290 Extracting Chromatograms at Different Wavelengths 291 Tell me about the Extract Chromatograms Operation 292 How do modify the parameters that are used to Extract Chromatograms isien aeai aa iaia iaai 296 Summary of Operation Extract Chromatograms s ccceeseeeeeeees 297 Apex Optimized Chromatogram
163. ges appears Move the box to the exact location you want Click outside the box The text is placed on the screen How do I delete annotations gt You can delete any annotation you have placed on the screen by selecting the annotation you wish to delete and then selecting Actions gt Annotations gt Delete from the menu bar If you wish to delete all annotations that appear on a page select Actions gt Annotations gt Delete All 325 Iris HPLC Spectral Processing Software Copying IRIS Images to other Locations IRIS allows you to copy complete screen images and paste them into applications such as Microsoft Word for Windows How do I copy the pixels of the screen display as a bitmap image To copy the view as a bitmap image gt From the menu bar select Edit gt Copy Screen As gt Bitmap The entire screen is copied to the clipboard You can now paste this image into any Windows application that supports bitmap images If you wish to edit the image you can paste the image into an application such as Paint How do I export a chromatogram or spectrum in numerical format for use in spreadsheet programs To export a displayed chromatogram or spectrum in numerical format for use in spreadsheet programs You can export a displayed chromatogram or spectrum to spreadsheet programs such as Microsoft Excel by using the Edit gt Copy Object command This command copies the chromatogram or spectrum in numerical for
164. grams Extracting Chromatograms at Different Wavelengths To extract chromatograms at different wavelengths you must first select an opened chromatogram from the Extract Chromatograms Data Tree The selected chromatogram is displayed in the top graph of this page You can then use the bottom graph to extract up to eight chromatograms To extract chromatograms all you need to do is enter an Analytical Wavelength for each chromatogram you want to extract However this operation also provides you with the ability to specify the following additional parameters for each chromatogram you want to extract Bandwidth Reference Wavelength and Reference Bandwidth After you have finished establishing the extraction parameters for up to 8 chromatograms select File gt Save Results to have IRIS save all of the extraction parameters to the appropriate spectral method files Once the parameters are saved you can then use AutoCalc to automate this operation during a TotalChrom sequence that will be processed with the same TotalChrom method that you specified when you extracted the chromatograms Then when a run is completed all of the wavelengths you have specified and saved to a method file are extracted automatically after each run For more information on automating this operation refer to Chapter 9 AutoCalc Automating Arithmetic Operations and Chromatographic Extractions Note The RAW files and corresponding RST files that are created as a result of pe
165. h Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Printing General Details Last Edited Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram 4 9 2006 2 39 43 PM Description Audit Trail Figure 1 5 The Default Method 29 Iris HPLC Spectral Processing Software Chromatogram s Spectral Method This is the spectral method associated with a chromatogram When a chromatogram is opened in IRIS for the first time IRIS automatically creates and saves this method which we refer to as the Chromatogram s Spectral Method IRIS names this method with the same name as the chromatogram s result file however the file extension is tsm instead of mth This method contains the parameter values that are responsible for the results you can see when a chromatogram is displayed on an operation in IRIS and the results that are stored with the TotalChrom result file IRIS initially creates this method by either copying the parameter values in the Default tsm method Or if you open a chromatogram in IRIS that has been processed by the same TotalChrom Method as a chromatogram previously opened in IRI
166. h Maximum of chromatographic peaks e Use the Spectral Standard Confirmation operation to verify the identity of chromatographic peaks by comparing to a standard chromatogram e Use the Spectral Library Confirmation operation to verify the identity of chromatographic peaks by comparing to a spectral library e Use the Peak Library Search operation to identify chromatographic peaks e Use the Retention Time Adjustment operation to properly assign the component names to a peak when TotalChrom misses the identification of peaks because they are outside the peak tolerance window or they are misassigned e Use the Extract Chromatograms operation to extract up to 8 chromatograms from a spectral file and automatically process them e Use the Apex Optimized Chromatogram operation to create a chromatogram with the optimum wavelength set for each peak e Save the results of the operations you performed on a chromatogram so that the corresponding TotalChrom Result file is updated with this information and the corresponding spectral method files are updated with the parameter values used to calculate the results Note Any of the arithmetic operations and chromatographic extractions listed above can be automatically performed during a TotalChrom sequence by means of the AutoCalc user program which is installed with your IRIS Spectral Processing software The results of the automated operations are automatically saved to the TotalChrom Result file
167. hanges This text box displays the reason that was selected when a specific change was made to an audit trail item Comment This text box displays the comments that were entered at the time the selected change was made Print Button This command button enables you to print the audit trail Export Button This command button displays a standard Microsoft file selector for you to select where to export and save the audit trail as a text txt file 52 Chapter 2 Enhanced Security Electronic Signatures An electronic signature as defined by 21 CFR Part 11 means a computer data compilation of any symbol or series of symbols executed adopted or authorized by an individual to be the legally binding equivalent of the individual s handwritten signature Electronic Signature Support in IRIS Note Electronic Signature support in IRIS is controlled by TotalChrom For more information on enabling electronic signatures refer to the TotalChrom Help The electronic signature feature forces a user who saves a file to enter the TotalChrom password that corresponds to the logged on user The electronic signature feature of IRIS is provided to assist in satisfying the requirements of FDA Final Rule in 21 CFR 11 Electronic signature works in conjunction with audit trail you can enable electronic signature in TotalChrom only on files for which audit trail has been enabled Once electronic signature has been enabled for a file it cannot be
168. he Spectral Math operation click anywhere inside the white space of the top Spectrum Pane this is the spectrum pane that represents Spectrum A for any mathematical operations you perform on this operation A blue border appears around the pane to indicate that the pane is selected From the Data Tree click on the spectrum that you wish to use as Spectrum A for performing mathematical operations The selected spectrum appears in the top Spectrum pane and will be considered Spectrum A in the mathematical operations you want to perform You must now select a second spectrum to be used in the calculation this spectrum will be considered Spectrum B in the mathematical you wan tto perform To select the second spectrum click anywhere inside the white space of the lower Spectrum pane Spectrum B this pane is below the Spectrum A pane A blue border appears around the pane to indicate that the pane is selected From the Data Tree click on the spectrum that you wish to use as Spectrum B for performing mathematical operations on this page The selected spectrum appears in the Spectrum B pane and IRIS automatically calculates and displays the result of the currently defined mathematical operation using the two selected spectra and the parameters currently displayed on this operation Note You can change any of the parameters used in the calculation as well as modify the calculation you wish to perform and IRIS will automatically recalculate t
169. he display with the recalculated results Below is a list of the parameters you can modify Minimum Use the Minimum Wavelength spin box to set the lower limit of the Wavelength spectrum range to be used for the match Maximum Use the Maximum Wavelength spin box to set upper limit of the Wavelength spectrum range to be used for the match Match retention Check this option if you wish to use the retention time of the time window spectrum as one of the search criteria When this option is checked the spin box is enabled This spin box specifies the search window as percent of retention time if you have checked the Retention Time Search option If you use retention time as a search criterion the search first creates a list of all spectra in the library that fall within the window it then does a spectrum by spectrum comparison If you don t use the retention time option the comparison is made with all spectra in the library Hit distance Use the Hit Distance Threshold spin box to specify the Hit Quality threshold above which two spectra will not be considered a match Baseline corrected Check this option if you wish to use baseline corrected spectra for the library match Library list Select this command button to display the Libraries List dialog 272 Chapter 8 Performing Operations on Chromatograms Summary of Operation Peak Library Search The summary below illustrates how to perform the Peak Library Search Operation for
170. he parameters that are used to match the library spectra to the peak apex spectra and when a match is found adjust the retention times gt L iris ragragna ennes PSEC eulbeseel ese Emsktp NEMAME fig exe eee r Man View Chrom Spectrs Corto Map Specht sX Compare Oper ations L eary Match Spectral Derivative Spec s Math Peak Asty Finerbarce Ratio Wevetiangth Maree Spectral Rarded ci Spectra Library Cor Peak Ute ary Search Retertion Tene Adh Extract Chromatoy Apex Optenited Or Custom Views i yi Benzene b Propi Ganzene 0017 p Component Crgrd acanted RY lt gt Gervere 187 Tokzor 282 Eth Derwere 27 275 Prooyt Benzene 5 3 5 33 Butyl Sonsene za CS z qxhergile Mderkied t 281 Iris HPLC Spectral Processing Software e Component List This list displays the component list as present in the TotalChrom Result File and the original and adjusted retention times When you make a selection in the Component List the corresponding peak in the chromatogram is highlighted in green and the spectral details that are checked on the Display List are displayed on the Results pane O08 If the component selected in the component list is unmatched the library spectrum can be displayed but there is no peak apex spectrum 282 Chapter 8 Performing Operations on Chromatograms Display aves O Spectiu
171. he result and display it in the Results Pane 197 Iris HPLC Spectral Processing Software To perform a mathematical operation on two spectra using a different set of parameters Once you have selected Spectrum A and Spectrum B IRIS automatically performs the calculation using the current parameter values displayed on your screen You can then modify any of the parameters displayed on the page for example you can specify new multiplication factors for Spectrum A and B or select a different mathematical operation to perform and with each parameter you modify the results are automatically recalculated and displayed on the operation To select new multiplication factors for Spectrum A and B 1 Select a multiplication factor for Spectrum A using the spin box next to a ae AO h ad 2 Select a multiplication factor for Spectrum B using the spin box next to z pe Po To select a different operator gt From the drop down list located between A and B select an operator d EJ for the calculation You can select to add spectra subtract spectra or divide spectra To reverse the order of a Division or Subtraction operation gt Check the Reverse Equation check box to switch Spectrum A and B and their multiplication factors in the function For example a function that read A 1 B 2 becomes B 2 A 1 when Reverse equation is checked This option is only enabled when the operator is or To add the result spectrum to the Da
172. he results pane to the Data Tree gt Select Actions gt Add All to View A dialogue box is be displayed with the message The data was added successfully On re displaying the Main or Chrom Spectra views the added spectra will apear in the Data Tree To save the results and parameters used in the calculation 1 Select File gt Save Results A save dialog appears that asks you to confirm whether or not you want to save the new values to the chromatogram s result file RST and save the parameters that were used calculate the results to the associated spectral method file TSM 2 To only save results for peaks that are currently identified named in TotalChrom select Currently identified peaks OR To save results for all peaks select Include unidentified peaks Any unidentified peaks for which results have been calculated are added to the TotalChrom result file as Unknown 1 Unknown 2 etc Any unidentified peaks which do not have results are not added to the file 3 Click Yes to save the results and calculation parameters Absorbance Ratio values added to the result file for all identified peaks To display the Absorbance Ratio results in the Main or Chrom Spectra view 1 Select Actions gt Label Chromatograms 2 Select Absorbance Ratio from the list of available labels To review for any chromatogram previously calculated Absorbance Ratio values and the parameters used gt Select this chromatogram
173. hen as soon as the Library Match operations is displayed IRIS matches the selected spectrum and displays the results on the screen f this is the case you can skip to step 5 OR If you have not already selected a list of libraries to search the Libraries List dialog appears 2 From the Libraries List dialog select the libraries you wish to search Note From the Library Match operation you can open the Libraries List dialog by clicking on the Library list button 3 Once you have selected the libraries you wish to search click OK to close the Libraries List dialog and return to the Library Match operation 4 Select the spectrum in the Data Tree that you want to identify The match is immediately performed and the results are automatically displayed on the Hits List The original selected spectrum appears first in the Hits List The subsequent hits are displayed in the order of the best match Each hit is listed first by its Hit Quality value the numeric value representing how close a match the library spectrum is to the currently selected sample spectrum and then by its library component name Note The Hit Quality is a measure of the similarity of the sample spectrum and the library spectrum Lower numbers are better matches 0 means a perfect match 5 If you want to compare the sample spectrum to specific matches check the Sample Spectrum check box and check any additional spectra listed on the Hits List that you want displaye
174. hen you enter 0 the Reference Channel is turned off to re enable the Reference Channel Method This text box displays the selected TotalChrom method This method will be used to process the new chromatogram to generate a new result files The file that appears here defaults to the same method that was used for the original chromatogram but you can select a different method to be used by clicking on the Browse button and selecting a method from the dialog box that appears or by typing the name of the method directly into the text box Browse Select the Browse button to display a standard Windows file selector From the file selector dialog you select the method file that will be associated with the chromatogram you are extracting 296 Chapter 8 Performing Operations on Chromatograms Summary of Operation Extract Chromatograms The following procedure shows you how to extract multiple chromatograms from a single result file at wavelengths other than the two specified by the photodiode detector 1 From the IRIS Views Tree expand the Operations node and select Extract Chromatograms The Extract Chromatograms operation displays Select an opened chromatogram from the Extract Chromatograms Data Tree The selected chromatogram is displayed in the top graph of this page OR If necessary open the required chromatogram using File gt Open gt Chromatogram To extract multiple chromatograms click on one of the radio
175. hromatogram with the optimum wavelength set for each peak The optimum wavelength for a peak is defined as the wavelength maximum of the apex spectrum of that peak gt To access this operation expand the Operations node on the Views tree and select Apex Optimized Chromatogram Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirt Spectral Library Confirme Peak Library Search 4 Retention Time Adjustme Extract Chromatograms Apex Optimized Chromat Custom Views ines A example1_well_separated001 example 4 identified butyl be CO DO CC PT SC CT 44 22 33 44 5 5 66 77 88 Apex Optimized Unresolved Peak COO DCCs CO Cy Ty AANA AJ KEEKEEKE AJ AA 41 1 2 2 3 3 44 5 5 6 6 77 8 8 0 244nm 0 0445Au Inti Iaticting feuiat gus LeUicMoList el ERA iat ede itr ot toy tt 220 275 330 385 Figure 8 9 The Apex Optimized Chromatogram operation 298 Med Apex Optimized Chromatogram Minimum Wavelength 230 Maximum Wavelength c Maximum Analytical Poo r X Reference Wavelength 400 X Reference Bandwidth pooo IV Baseline corect spectra Absorbance Threshold Auto C Manual 0 0005 4 za J Display Apex M Baseline Login manager amp 4 Chapter 8 Performing Operations on Chromatograms Rules for setting the wavelength for a peak The Apex Optimized Chromatogram operation is a specialized version of the Extract
176. hromatograms We then selected File gt Print Selected Pane Only From the Chromatogram tab page on the Print dialog we then seelcted the Separate Plots option with 2 plots per page The first page of the print out contained a color coded key identifying each chromatogram included on the print out and the second page is shown below Note Ifyou had more than two chromatograms that you wanted to print and you selected to print 2 Separate Plots per page then your report would consist of multiple pages with two chromatograms displayed on each page Operation ChromySpectra View gt Date 07 13 2006 12 5246 PM Eastern Standeed Time Perkineirner User mamger Page 202 OLET CLEEF OUD CILIT CELLU Gu CD CUO TELIT TELIT LU LL TEREN EEEE U 2 BLL CLEEF KERET ELLAS DLL KEKET CLEES CUO RT TELIT LU Ld LELEN TELET Li 335 Iris HPLC Spectral Processing Software Labels From this section you specify which label will be displayed on the printout As View Prints the label currently displayed on the view for the selected Chromatogram pane Specified Enables a drop down menu from where you select a specific label for the printout Spectra tab page From the Spectra tab page you can define the print layout for the spectra displayed in the currently selected pane You can select to print the currently displayed spectra overlaid on one plot or stacked on one plot or you can select to print separate plots for each current
177. ic Operations Extractions and Apex Spectra Printing AutoCalc Print Setup General Printer Adobe PDF Preferences Orientation Portrait Landscape Print What g C Apex Spectra All Known Peaks Only Peaks with Absorbance Over pos i Cancel Select a printer from the Printer drop down list and then if desired click on the Preferences button to define the settings for the printer Select one of the following Orientation options Portrait or Landscape Under the Print What section notice that the Apex Spectra radio button is the only option enabled on this dialog From this section you define which apex spectra will be included during a running sequence that will be processed by the same TotalChrom method that was used to process the chromatogram you opened in Step 1 You can select to print all of the apex spectra or just the apex spectra from known peaks or to print the apex spectra for peaks that are above a specific absorbance limit Click Save when are finished specifying the printing parameters The printing parameters are saved to the Process Spectral Method that you identified in Step 2 Moreover for AutoCalc these parameters can now be used by any chromatograms that will be processed by the TotalChrom Method having the same name as the Process Spectral Method you just updated 321 Chapter 10 Printing and Presentations Chapter 10 Printing and Pre
178. iew the Data Tree displays a list of open chromatograms From the Data Tree you select the chromatogram you want to display Only one chromatogram can be selected at a time Note When the 3D Spectra View or the Contour Map View is displayed the spectra that appeared on the Data Tree prior to accessing either view are not shown on the Data Tree Only opened chromatograms are displayed on the Data Tree for the 3D Spectra View and the Contour Map view The spectra are not lost and will reappear when you change the view It should also be noted that when you extract spectra from a chromatogram displayed on a 3D Plot or Contour Map the spectra are not displayed in the Data Tree until you select another view such as the Main View or Chrom Spectra View In addition chromatograms that are extracted on these views are temporary and will be cleared from the chromatogram pane when you select a different view Eg Gexample 1 benzene to anthracene identified well separated 1 429 2 559 Figure 1 3 The Data Tree 10 Chapter 1 Introduction How are Chromatograms and Spectra listed on the Data Tree When you open a chromatogram or spectrum via the File gt Open gt Chromatogran y Spectrum command the chromatogram or spectrum appears at the bottom of the list on the Data Tree and the newly opened item is selected on the Data Tree and displayed in the appropriate pane unless a View or Operation is selected that does not allow you to
179. important that you learn about how these operations are calculated In IRIS all of the parameter values used to calculate the results of an operation are stored in spectral method files There are three types of spectral methods in IRIS Default Method Chromatogram s Spectral Method and a Process Spectral Method Following is s description of each method and how it is used by IRIS 28 Default Method Chapter 1 Introduction IRIS provides you with a method named Default TSM that contains the default set of parameters for all operations that can be performed in IRIS The parameters specified in this default method are used to set the initial parameter values for new spectral methods created by IRIS In fact whenever you open a chromatogram in IRIS for the first time and the chromatogram has no associated Process Spectral Method then both the Chromatogram s Spectral Method and the Process Spectral Method are created as a copy of the Default tsm method You can view and edit the parameter values in the default method by selecting Tools gt Edit Default method from the IRIS menu bar The Method Editor Default tsm dialog that appears provides you with a convenient way to set the default initial conditions for new spectral methods that will be created by IRIS For more information see page 39 Method Editor Default tsm General Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelengt
180. imum The library s maximum wavelength value appears here Wavelength Spectra List The Spectra List shows all the spectra currently in the Library by component name You can click on a spectrum from this list to have the selected spectrum displayed the graph below If you right mouse click on a select spectrum and select Properties a dialog appears that displays the source the chromatogram and retention the baseline and who added the spectrum and when Baseline corrected This check box allows you to select whether or not the spectra displayed on this dialog have been baseline corrected Note This checkbox only determines what is displayed on the View Library dialog it does not determine whether or not baseline corrected spectra are used in library operations Show Baseline This checkbox allows you to select whether or not the baseline spectrum is also displayed on the graph Audit Trail Click on this button to display the audit trail for the library 161 Iris HPLC Spectral Processing Software Editing a Library The Edit Library dialog is used to add replace or delete spectra in addition this dialog can be used to browse through the spectra in a library The Edit Library dialog automatically appears after you have created a new library However this dialog can also be accessed by selecting Tools gt Build Library gt Edit and then selecting the library you wish to edit from the Library File Selector dialog box
181. imum absorbance values above the system noise and therefore obtain more reproducible results e When Auto is selected the absorbance threshold values are calculated automatically by the system and are set to either 0 0005 A U or 2 of the maximum absorbance in the spectrum whichever is greater The entry field is greyed when Auto is selected When Manual is selected enter the required value in the entry field by either typing directly or using the spin buttons When Manual is first selected the minimum absorbance value calculated by the Auto function is displayed in the Manual threshold field 222 Chapter 8 Performing Operations on Chromatograms Summary of Operation Absorbance Ratio The summary below illustrates how to optimize adjust the Absorbance Ratios for a chromatogram and then save the new results and parameters used in the calculation To review and recalculate Absorbance Ratios for a chromatogram 1 From the Views tree expand the Operations node and click on Absorbance Ratio The Absorbance Ratio operation displays 2 If necessary open the required chromatogram using File gt Open gt Chromatogram 3 Select a chromatogram from the Data Tree The selected chromatogram is displayed The first peak is selected The Results pane directly below the chromatogram shows for the selected peak its peak apex spectrum annotated with the position of the two wavelengths and absorbances its Absorbance Ratio
182. in 149 Iris HPLC Spectral Processing Software Custom Views You can create your own Custom views by modifying an existing view You can modify existing views by selecting to hide or show a particular pane When a default view is modified a custom view is automatically created gt To hide or show a pane on a view page select View gt Panes from the menu bar The Panes sub menu allows you to select whether or not a Chromatogram pane Spectrum pane Contour Map pane or 3D Plot pane is displayed on the View OR Right mouse click on the pane you wish to hide and select Hide Pane from the context menu that appears gt Once you have modified an existing view you can save it as a Custom View by selecting View gt View Template gt Save As from the menu bar The name of the view you saved now appears under the Custom node on the Views tree Ee We Iris File Edit View Actions Tools Help aieialolalal2 mal Hejo m eoe aeea gt Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views Custom View 06115 226335445555 665775885 9 EE T example 1 identified and well sei M1 613 2 464 3 667 UJ KUKACA E EEEE E E E EE E EE E E E EE e peer er ee 05115 225335 4455556657758859 Login manager amp Figure 5 6 An example of a Custom View 150 Chapter 6 Spectral Libraries Iris HPLC Spectral Processing Software Ab
183. in a chromatogram 1 From the Data Tree select a chromatogram that has named peaks 2 Select Tools gt Build Library gt Add Apexes The New Library dialog appears 3 Select location to save the new library and enter a name for the library in the File name field New Library Save in e Library vy e ex EJ Example Library alb My Documents atakae File name Add Apexes Example v aces Save as type Iris Library File alb M Cancel 4 Click Save The Create Library dialog appears Create Library Minimum Wavelength 130 a Maximum Wavelength Cancel 5 From the Create Library dialog use either the default values for the Library Minimum and Maximum Wavelengths OR 154 Chapter 6 Spectral Libraries If you are working in a different range enter new Minimum and Maximum Wavelength values that cover the range of spectra collected For example specify a range of 190 400 for UV only data or specify 400 700 for visible only data or 190 700 for UV and visible data 6 Click OK to close the Create Library dialog The Audit Trail dialog appears 7 Depending upon how your TotalChrom Administrator has configured Audit Trailing you may be required to enter a Comment about the library you are creating If your TotalChrom Administrator has created a Reasons list in TotalChrom you may also be required to specify a Reason on the Audit Trail dialog 8 Click OK when you have
184. int outs you wish to automate via a user command line in the Process section of a TotalChrom method Note Normally you will not need to specify a specific IRIS Process Spectral Method as part of the command line By default IRIS will use the Process Spectral Method with the same name as the TotalChrom method that will be used to process the sequence If the TotalChrom Method is unavailable then AutoCalc operations will use the default spectral method In order to implement AutoCalc 1 From TotalChrom s main window the Navigator screen open the required method using Method Editor 2 Select Process gt User Programs from the menu bar 3 Under lt Drive gt Program Files PerkinElmer I nstruments I ris select AutoCalc exe as a user program under Program Name and Options Note The directory path may be somewhat different depending on any changes opted during software installation Process integration Baseline Timed Events Optional Reports Replot User Programs Program Name and Options A e aa SS SI c l o Command iine SRST run WM PT Ea Execute after Quantitation X Synchronize with data analysis 317 Iris 4 HPLC Spectral Processing Software In the Command line text box type RST run followed by any combination of operations codes depending on the automated operations that are desired see example above Always end the last operation with a quote For the correspo
185. ions for Scaling Spectra This section describes the scaling commands you can use to in order to modify the spectrum display You will find that the information in this section is useful when multiple overlaid spectra are displayed Note Before you use any of the scaling commands to modify how spectra are displayed you must first select the Spectra pane by clicking on the white space of the pane When the Spectra pane is selected a blue border appears around the pane Now that you have the Spectra pane selected you can use the scaling command s described below to more easily compare spectra Autoscaling Spectra The autoscale commands allow you to rescale the data in the Spectra pane so that all of the data are visible As noted earlier the autoscale commands are particularly useful when multiple overlaid spectra are displayed There are two commands which you can use to scale spectra to fit the display region e The Autoscale X and Y command rescales spectra on the current view in both the X and Y directions so that all of the data are visible This command is particularly useful when multiple overlaid spectra are displayed because clicking on this command rescales the data so that all points for the largest data set in both the X and Y axis directions fit in the window e The Autoscale Y Only command S works like the Autoscale X and Y command described above except that it leaves the X axis unchanged and scales only the Y axis
186. is added to the Data Tree however you will not see the extracted spectrum on the Data Tree until you exit the Contour Map View The reason for this is because on the Contour Map View the Data Tree is used only for selecting the chromatogram that you want displayed You will be able to see all of the spectra you have extracted once you select a different View such as the Main View or the Chrom Spectra View 81 Iris HPLC Spectral Processing Software How do I capture a spectrum from a 3D Plot To extract and display a spectrum from a point on the Contour Map 1 On the Main View check the chromatogram on the Data Tree that you want displayed as the 3D Plot The chromatogram is displayed on the Chromatogram pane Contour Map pane and 3D Plot pane 2 Float your mouse pointer over a point on the 3D Plot to temporarily view in the Spectra pane the spectrum from that point As you continue to float your mouse pointer over the 3D Plot the Spectra pane automatically updates so that the spectrum from the current location of your mouse pointer is displayed in the appropriate pane 3 If you see a spectrum that you want extract just double click on that area in the 3D Plot and the spectrum at the wavelength and time you clicked appears in the Spectra pane Note Unlike the Main View where extracted spectra are displayed on the Data Tree when you extract a spectrum from the Spectra 3D View the spectrum is added to the Data Tree however
187. is your responsibility to ensure that you have documentation on how the chromatogram was created For this reason this operation cannot be performed by AutoCalc 308 Chapter 8 Performing Operations on Chromatograms Saving the Results of a Calculation The File gt Save Results command allows you update a chromatogram s result file with the results of any operation performed on a chromatogram in IRIS thereby allowing you to include these results in a TotalChrom report The parameter values used to obtain these results are saved in the Chromatogram s spectral method file and the Process Spectral Method associated with the chromatogram To save the results of an operation 1 After you have performed an operation on a chromatogram select File gt Save Results from the IRIS menu bar The Save Results confirmation dialog appears Note The Save Results dialog differs slightly depending upon the type of operation you have performed 2 From the Save Results dialog you are prompted to confirm whether or not you want to save the new values to the chromatogram s result file RST as well as update the chromatograms spectral method files TSM with the parameter values that were to determine the results of the operation you just performed If the operation you performed could only be performed on Identified peaks skip to step 4 Operations that can only be performed on identified peaks are Spectral Standard Confirmation Spectr
188. isplay axes can be scaled independently IRIS also provides you with the ability to view chromatographic data on a three dimensional plot that provides a scaleable perspective on the complete data set Extract and reprocess actual chromatograms at any wavelength you desire directly from spectral data files Chromatograms spectra and other data can be printed using a color printer such as the HP Deskjet 5650 You can annotate and export screen displays to other Windows programs to generate presentation graphics or documentation You can also export numerical data to programs such as Microsoft Excel for additional study Chapter 1 Introduction Starting IRIS Before accessing the IRIS application make sure you have a valid TotalChrom User Name and Password since access to IRIS is controlled by TotalChrom If your user account and password have not been set up in TotalChrom contact your System Administrator who is responsible for maintaining the TotalChrom application and is the contact person for all technical support issues For more information on setting up user accounts see the section titled User Management on page 44 Once you have a valid TotalChrom User Name and Password you can start IRIS a number of different ways This section introduces you to the various ways you can start IRIS Starting IRI S from Windows You can start IRIS directly from Windows from the Windows Start menu or if you have added the IRIS a as a shor
189. isted for the operation you selected e Select the next operation that you want to make changes to When you select a different operation a dialog appears that prompts you to select if you want to save the changes From this dialog select the desired save mode and click Yes 3 After completing the changes for the last operation save the results via File gt Save Results The Process Spectral Method and the Chromatogram s Spectral Method are then updated with all the modified parameter values Moreover for AutoCalc the Process Spectral Method parameters can now be used by any chromatograms processed by the TotalChrom Method having the same name 38 Chapter 1 Introduction Editing the Default Method to set the default initial conditions of a new method Note If you have the appropriate user permissions you can edit the default method by selecting Tools gt Edit Default Method from the IRIS menu bar The Default Method contains the default set of parameter values for all operations that can be performed in IRIS When you open a chromatogram in IRIS for the first time and the chromatogram has no associated Process Spectral Method then both the Chromatogram s Spectral Method and the Process Spectral Method are created as a copy of the Default tsm method The Edit Default Method dialog provides you with a convenient way to specify the default initial conditions that IRIS will use to create a new method gt To access the Defa
190. items are not displayed You can select to display the Sample Spectrum First Derivative Second Derivative Third Derivative and or the Fourth Derivative When you select or deselect any one of the check boxes in the Display list the Derivatives Pane is automatically updated B Sample Spectrum First Derivative B Second Derivative E Third Derivative E Fourth Derivative Note The check box options from the Display List and the curves on the Derivatives Pane have matching color coding 184 Chapter 7 Performing Operations on Spectra Derivatives Pane This pane provides a graphical display of the derivative spectra that appear checked on the Display List It should also be noted that whenever you select a new sample spectrum change the parameters for the calculation or select deselect an item on the Display List the Derivatives Pane is automatically updated Display J Sample Spectrum v First Denvative Ce ee es ee 13 C8 C3 C3 185 Iris HPLC Spectral Processing Software Summary of Operation Spectral Derivitives The summary below illustrates how calculate spectral derivatives for a spectrum To calculate spectral derivatives Note Ifyou want to calculate spectral derivatives on a spectrum extracted from a chromatogram the spectrum must be extracted and displayed on the Data Tree prior to accessing the Spectral Derivative page 7 10 From the Views Tree select Operations gt Sp
191. itive and two spectra are rarely absolutely identical We have found in practice that a value between 1 00 and 1 50 will usually indicate that the spectra are the same and that the peak is pure Two practical factors have to be considered when actually performing the test The first is that a result of dividing two noisy numbers close to zero is very unstable and could easily affect the minimum or maximum value in the final calculation To avoid such errors an absorbance threshold is set in the calculation Absorbances in the spectra that fall below this threshold are not used in the calculation The default value for this absorbance threshold is 0 0005 AU or 2 of the maximum absorbance in the spectrum whichever is the greater This threshold value can be changed within IRIS 1 Poile A F and R D Conlon J Chrom 204 1981 149 152 350 Appendix 1 Calculation Algorithms The second factor results from the threshold just described Clearly the threshold removes some data points from the calculation It is possible for low absorbance spectra especially if the minimum and maximum wavelength has to be set to a narrow range to have insufficient points for a valid calculation to be performed A second threshold the Minimum Data Points threshold is therefore applied which determines if the calculation can be performed This value defaults to 20 within IRIS but it can be changed Euclidean Distance Algorithm The Euclidean Distance i
192. ized Chromatogram operation You can access this operation by expanding the Operations node and selecting Apex Optimized Chromatogram ex Optimized 300 Chapter 8 Performing Operations on Chromatograms e Data Tree The Data Tree displays a list of currently loaded chromatograms You use the Data Tree to select the chromatogram that you want to use in the operation The chromatogram you select from the Data Tree is displayed in the upper pane Chromatogram pane for this operation Note When you select a chromatogram from the Data Tree IRIS checks that the TotalChrom method used to generate the result file from the raw file can still be found This TotalChrom method will be used later to process the optimized chromatogram If the method cannot be found an error message is displayed that informs you that the raw Apex Optimized chromatogram can be saved but not the result file 301 Iris HPLC Spectral Processing Software e Sample Chromatogram Pane This pane displays the chromatogram that you selected from the Data Tree It should be noted that unlike the chromatogram panes in other operations you cannot select chromatographic peaks on this pane Fie Edt View Actions Too Heb e as S E IES eai METERAN m nh Apes Opieneed Cheonsloge Spectral Derivative Spectra Matt Post Putty Absorbance Rabe Waveleng Mamm f Spedra Standard Corta es Magram W avelergh Spectral L r ary Corfeme F a00 Pow Ltrar
193. l currently displayed on the IRIS workspace for the selected chromatogram pane Specified Enables a drop down menu from where you select a specific label for the printout 5 When finished click Print To define the format for printing the currently selected spectra pane This section applies only to views where a Spectra pane is currently selected 344 Chapter 10 Printing and Presentations From the current view click on the Spectra pane that contains the spectra that you want to print Click File gt Print The Print dialog displays aater a Peene fe All f Known Peaks Only f Peaks with Absorbance Ower 0 000 345 Iris 5 346 HPLC Spectral Processing Software On the Print dialog click Selected Pane only The Chromatograms tab page is enabled Click on the Spectra tab page The Spectra tab page displays General Chromatograms Curves As View Overlaid Stacked C Separate Plots m From the Spectra tab page you can define the print layout for the spectra displayed in the currently selected pane You can select to print the currently displayed spectra overlaid on one plot or stacked on one plot or you can select to print separate plots for each currently displayed spectrum The following options are available to you on the Spectra tab page As View Prints an image of the Spectra pane that is currently selected and displayed on the IRIS window Overl
194. l to View A dialogue box is be displayed with the message The data was added successfully On re displaying the Main View or Chrom Spectra View the added spectra will appear in the Data Tree To save the results and parameters used in the calculation Note When you save the results of this operation any existing component lists are deleted and a new component list is created 1 Select File gt Save Results A save dialog appears that asks you to confirm whether or not you want to replace the component list in the chromatogram s result file and asks you to confirm whether or not you want to save the new values to the chromatogram s result file RST and save the parameters that were used calculate the new values to the associated spectral method files TSM 2 Click Yes A dialog apepars that asks you to confirm that you are sure you want to replace the component list in the chromatogram s result file 3 Click Yes Peak Library Search values added to the result file 274 Chapter 8 Performing Operations on Chromatograms To display the Peak Library Search results in the Main View or Chrom Spectra View 1 Select Actions gt Label Chromatograms 2 Select Peak Library Search from the list of available labels To review for any chromatogram previously calculated Peak Library Search values and the parameters used gt Select this chromatogram again on the Peak Library Search operation The saved resu
195. le RST and save the parameters that were used calculate the results to the associated spectral method file TSM To only save results for peaks that are currently identified named in TotalChrom select Currently identified peaks OR To save results for all peaks select Include unidentified peaks Any unidentified peaks for which results have been calculated are added to the TotalChrom result file as Unknown 1 Unknown 2 etc Any unidentified peaks which do not have results are not added to the file Click Yes to save the results and calculation parameters Peak Purity values added to the result file for all identified peaks The saved results can now be displayed as peak labels when the chromatogram is displayed in IRIS in the Main or Chrom Spectra View In addition when you select this chromatogram again on the Peak Purity operation the saved results and the parameters used are displayed on the screen To display the Peak Purity results in the Main or Chrom Spectra View 1 Select Actions gt Label Chromatograms 2 Select Peak Purity from the list of available labels To review for any chromatogram previously calculated Peak Purity values and the parameters used gt Select this chromatogram again on the Peak Purity operation The saved results and the calculation parameters are automatically displayed 213 Iris HPLC Spectral Processing Software Absorbance Ratio The Absorbance Ratio of a comp
196. lected a Chromatogram pane on the Chrom Spectra View that contained two overlaid chromatograms We then selected File gt Print Selected Pane Only From the Chromatogram tab page on the Print dialog we then seelcted the Stacked option The first page of the print out contained a color coded key identifying each chromatogram included on the print out and the second page is shown below Operation ChromySeectra View I gt Date 07 13 2006 12 51 23 PM Eastern Standard Time Perkin imor User manager Page 2a 2 rues Benzepe p enzene thy Benzene Propy Benzene thy Benzen v e v v a uty Benzene LLLLI IRERERE CELLS LE LIGOeeEeeLs TLETT LE TETTERETEETIT TELIT Pisses Resell TITEN Leese LI as 1 5 2 2s 3 355 4 AS 5 s5 6 65 7 7 3 e 3 Note This option will print all of the chromatograms that are displayed in the selected pane on one page However you can use the Separate Plots option to define exactly how many chromatograms you want displayed on a printed page 334 Chapter 10 Printing and Presentations Separate Plots Prints each chromatogram that is displayed on the currently selected Chromatogram pane on separate plots When this option is selected the per page spin box is enabled and from this spin box you specify the number of plots that will be printed on each page Example n the example below we selected a Chromatogram pane on the Chrom Spectra View that contained two overlaid c
197. ll obviously have a higher percentage of the earlier eluting component than those taken at the peak apex Similarly spectra taken close to the end of the peak will have a higher percentage of the later eluting component In practice of course the closer to the baseline the spectra are taken the lower the signal to noise will be in the spectrum For all spectra collected from the Series 200 DAD spectra are collected continuously across the peak Within IRIS you can therefore select where on the peak you want to take the two spectra To check the peak purity IRIS first divides the two spectra If they are identical except for concentration the result of this division will be a straight line parallel to the wavelength axis If however the two spectra are different then deviations from the straight line will occur The greater the difference between the two spectra in terms of both the shape of the spectral peak and its wavelength maximum the greater will be this deviation The deviation is quantitated simply by dividing the maximum in the resulting plot by the minimum If the spectra are identical the resulting plot is a straight line and the Purity Index will be 1 00 Note that this result is independent of the concentration of the components in the two spectra If the two spectra are not identical then the plot deviates from the straight line and the Absorbance or Purity Index will always be greater than 1 00 The test is very sens
198. lts and the search parameters are automatically displayed 275 Iris HPLC Spectral Processing Software Retention Time Adjustment Within TotalChrom peaks are identified on the basis of their retention time If a peak moves outside a preassigned retention time window that peak can be either misidentified or be left unidentified The Retention Time Adjustment operation allows you to readjust the retention time window so that TotalChrom can then successfully identify the peak It accomplishes this by matching the peak apex spectrum in the chromatogram to library spectra and then adjusting correcting the retention times in a chromatogram s result file rst It should be noted however that if there are matching results in the elution times of the component being switched IRIS cannot update these components and the existing retention time will not be modified If the scenario just described is true IRIS will notify you of this situation gt To access this operation expand the Operations node on the Views tree and select Retention Time Adjustment File Edit View Actions Tools Help aieinlelaielainialivieleloiors nE a Retention Time Adjustment Sample Retention Time Adjustment Main View Chrom Spectra Contour Map Spectra3D Compare Operations Maximum Wavelength Library Match 400 4 Spectral Derivative Spectral Math Hit Distance Threshold Peak Purity 0 05 Absorbance Ratio oo Wavelength Maxime Spectral Sta
199. ly displayed spectrum Curves As View C Overlaid C Stacked C Separate Plots ma Figure 11 6 The Spectra tab page is enabled when you select the Selected Pane only radio button on the General tab page and can be used when a Spectra pane is selected on the current view 336 Chapter 10 Printing and Presentations The following options are available to you on the Spectra tab page As View Prints an image of the Spectra pane that is currently selected and displayed on the IRIS window Example n the example below we selected a Spectra pane on the Chrom Spectra View that contained five overlaid spectra We then selected File gt Print Selected Pane Only From the Spectra tab page on the Print dialog we then selected the As View option The first page of the print out contained a color coded key identifying each spectrum included on the print out and the second page is shown below Operation CheomySpecta View gt Date 07 13 2006 1255 30 PM Eastern Standard Time Perkin immer User manager neay Page 22 oP E yee ate E E Pople meet a O aescir pt ean Overlaid Prints the spectra which are displayed on the currently selected Spectra pane using an overlaid display 337 Iris HPLC Spectral Processing Software Stacked Prints the spectra which are displayed on the currently selected Spectra pane using a stacked display Example n the example below we selected a Spectra pane on the
200. m The Open Spectrum dialog appears 2 Select the spectral file UV that you want to open and click Open The Open dialog closes and the spectrum appears checked in the Data Tree How do I capture a spectrum from the Chromatogram pane To view spectra associated with a particular chromatogram as well as extract spectra from a chromatogram the Chromatogram pane must use a stacked display and the Spectrum pane must use an overlaid display gt You can set the display modes for both panes by selecting Stack Chromatograms and Overlay Spectra from the View menu To extract spectra 1 Click on any area in the white space of the Chromatogram pane 2 Set the selected Chromatogram pane to a stacked display by clicking on the Sa Pa Stack Overlay icon Xx so that the icon appears to be pushed down x 3 Float your mouse pointer over a point on the chromatogram to temporarily view in the Spectra pane the spectrum from that point As you continue to float your mouse pointer over the chromatogram the Spectra pane automatically updates so that the spectrum from the current location of your mouse pointer is displayed in the appropriate pane 4 If you see a spectrum that you want extract just double click on the spot in the chromatogram that contains the spectrum you want to extract The spectrum at the wavelength and time you clicked appears in the Spectra pane 115 Iris HPLC Spectral Processing Software How do I capture a sp
201. m that point is temporarily displayed on the Chromatogram pane If you want to temporarily extract a chromatogram from the 3D Plot just double click on an area in the 3D Plot and the chromatogram at the wavelength and time you clicked appears in the Chromatogram pane Note Chromatograms that are displayed on this pane are only temporary and will be cleared when you leave the Spectra 3D View a i ny mt ot J ey kada 41 22 33 44 55 66 77 68 136 Chapter 5 Viewing the Data e Spectra Pane This pane displays the spectrum from the retention axis point selected on the 3D Plot pane To display a spectrum on this pane simply float your mouse pointer over the 3D Plot and the spectrum from that point is temporarily displayed on the Spectra pane If you want to extract a spectrum from the 3D Plot just double click on an area in the 3D Plot and the spectrum at the wavelength and time you clicked appears in the Spectra pane Note When you extract a spectrum from the Spectra 3D View the spectrum is added to the Data Tree however you will not see the extracted spectrum listed on the Data Tree until you exit the Spectra 3D View The reason for this is because while you are viewing the 3D Spectra View the Data Tree is used only for selecting the chromatogram that you want displayed on the view You will be able to see the extracted spectra once you select a different view such as the Main View page or the Chrom Spectra View gt The Add
202. m Baseina gn If a component is not matched to a peak the component in the Component List is labeled as Not Found If a component in the Component List is not present in the spectral library it will be marked a Not Present in Library 283 Iris 284 HPLC Spectral Processing Software Display List You use the Display List to select the information you want displayed on the Results pane When items appear checked on this list they are displayed in the Results pane Meanwhile unchecked items are not displayed The following items are available for selection on the Display List Apex Check this item to display the apex spectrum of the currently selected peak Spectrum Baseline Check this item to display the baseline spectrum for the currently selected peak Library Check this item to display the library spectrum identified as a match for the selected peak Library Baseline Check this item to display the baseline spectrum from the library spectrum O trary Hasolino Chapter 8 Performing Operations on Chromatograms Results Pane The Results pane displays the items that appear checked on the Display List From this pane you can view the apex spectrum of the currently selected peak and matching library apex spectrum Fle Ee View Actions Took Heb si ich a ey S P ey 2 f Al Beer el AAE Reterhon T me Aduutment Chrom Spectrs Contou Map Spectra Compare Cowitions lt
203. mat to the clipboard 1 If you are using a stacked display click on the chromatogram or spectrum that you want to copy OR If you are using an overlaid display where only one chromatogram or spectrum is currently visible click on that pane 2 From the menu bar select Edit gt Copy Object The chroatogram or spectrum is copied in numerical format to the clipboard You can paste these values into a spreadsheet program such as Microsoft Excel Spectra data are copied to the clipboard in wavelength absorbance pairs Chromatographic data are copied to the clipboard in retention time absorbance pairs The resolution of the data is at the original data collection rate 326 Chapter 10 Printing and Presentations Printing Chromatograms and Spectra from IRIS On any view or operation in IRIS you can select File gt Print to specify the format for printing chromatograms and spectra that are currently displayed on the IRIS window Note We recommend that you use a color printer since a black and white printer will not allow you to distinguish between multiple plots if more than one chromatogram or spectrum is being printed gt To print chromatograms and spectra from a view or operation select File gt Print from the IRIS menu bar The Print dialog displays On this dialog you define the format and printer that will be used to generate a print out of data currently displayed in the IRIS window Chromatograms Spectra
204. matogram s Spectral Method and a Process Spectral Method Unless you are viewing the Default TSM method This method contains the default initial conditions for all new methods that are created by IRIS when you open a chromatogram in IRIS for the first time you cannot edit any of the fields that are displayed on the View Method dialog The View Method dialog only allows you to view and print the parameter values for a spectral method All other IRIS spectral methods are updated only when you save the results of a chromatographic operation To modify a Chromatogram s Spectral Method 1 Open the chromatogram in IRIS 2 Select the operation from the Views tree that you wish to modify 3 Select the chromatogram on the Data Tree The Chromatogram is displayed on the operation you have selected 4 Modify the parameters that are listed on the right hand side of the operation 5 When you are satisfied with the results select File gt Save Results from the menu bar The results of any of the operations you perform on a chromatogram in IRIS can be saved to the chromatogram s result file RST and the parameters that were used calculate the results are saved the associated spectral method files TSM The saved results can to be included in a printed TotalChrom report You can View the new parameter values from the View Method dialog 37 Iris HPLC Spectral Processing Software To modify a Process Spectral Method When you
205. matograms annotated with apex spectra Iris HPLC Spectral Processing Software Features of RIS With the IRIS software you can View chromatographic data as a chromatogram as a contour map or as a three dimensional plot Gain access to all of a chromatogram s associated spectra and perform various calculations using those spectra Conduct on screen spectral comparisons or use the software to perform more complex operations such as adding subtracting dividing and obtaining derivatives of spectra Identify peaks and calculate peak purity Confirm the identity of chromatographic peaks by comparing them with other peaks or standards Using IRIS you can annotate chromatograms with spectral positions retention times component names or calculated values such as concentrations or purity indices To help you visually compare data chromatograms and spectra can be normalized offset normalized or displayed full scale The software also allows you to create and browse through spectral libraries to search those libraries for spectral matches to an unknown spectrum and to confirm peak identities by matching their spectra to those of known peaks in the libraries Use a two dimensional contour map to find chromatographic peaks which may not be showing at the wavelength used for the chromatogram You can use the contour map to obtain a spectrum and chromatogram at any point on the display The time absorbance and wavelength d
206. maximum values for the selected chromatogram on both the X and Y axes Format Graphs Chromatograrn Spectrum Contour Map l 3D Plot Limits EITEATETTEITEITI TITEI ETTEI RITET ETTEIT ENT EYIETIYEITE COL CURL DOO DLLs Fal ZS 33 4 4 55 6 6 Tot 8 8 99 aj aj 0 01 10 m Colors Background Axes M Figure 3 5 The Chromatogram tab page allows you to scale the X and Y axes for a chromatogram 2 From the Chromatogram tab page specify the Maximum and Minimum values for the X and Y axes 3 Click OK to apply changes and close the Format Graphs dialog 67 Iris HPLC Spectral Processing Software How do I use the Autoscale tools The autoscale commands allow you to rescale the data in the chromatogram pane so that all of the data are visible There are two commands which you can use to scale a chromatogram to fit the display region Autoscale X and Y G scales the chromatogram to between 10 and 90 of the absorbance axis as well as displaying the full retention time e range of the chromatogram Autoscale Y only L scales only the absorbance axis without changing the retention time range To autoscale the absorbance only 1 2 Click on the Chromatogram pane you want to autoscale in the Y direction Select Actions gt Autoscale gt Y only OR Click on the Autoscale Y icon L The absorbance axis of the selected chromatogram is scaled to fill 80 of the display To autoscale both the ret
207. me order as the chromatograms displayed on the Chromatograms pane You can float your mouse pointer over the 3D Plot pane to temporarily view a single spectrum and chromatogram from a point on the 3D Plot pane Mote the Chromatogram and Spectra panes must be set to an Overlaid Display If you want to extract spectra from this pane click on any area inside the white space of the Spectra pane set the Spectra pane to an overlaid display and then double click on the area in the 3D Plot that contains the spectrum you want to extract If you want to temporarily capture a chromatogram from the 3D plot just double click on an area in the 3D Plot pane and the chromatogram at the wavelength and time you clicked appears in the Chromatogram pane in the Main View Note Chromatograms that are captured from a 3D Plot are only temporary and will be cleared when you leave the Main View For information on using the 3D Spectra View to capture chromatograms and spectra see page 132 Virws Data reste am he se st 113 Iris HPLC Spectral Processing Software How do I adjust the pane width and height You can adjust the height and widths of any of these panes to make them smaller or larger To adjust panes 1 Place the pointer over the edge of the pane that you want to adjust The pointer turns into a line with arrows on each end Tes 2 Press the left mouse button and drag up down left or right The pane is resized aft
208. mum Auto Select this radio button to have IRIS automatically set the absorbance minimum The maximum wavelength will not be calculated in any area below this threshold in order to prevent erroneous assigning maxima to random noise Manual Select this radio button if you want to manually set the absorbance minimum value The maximum wavelength will not be calculated in any area below the value you specify This prevents erroneous assigning maxima to random noise 307 Iris HPLC Spectral Processing Software Summary of Operation Apex Optimized Chromatogram The summary below illustrates how to create a chromatogram with the optimum wavelength set for each peak To create a chromatogram with the optimum wavelength set for each peak in a chromatogram 1 Expand the Operations node on the Views Tree and select Apex Optimized Chromatogram The Apex Optimized Chromatogram operation is displayed Select a chromatogram from the Data Tree The chromatogram is displayed on the Sample Chromatogram pane with the first peak selected and IRIS calculates the optimum wavelength for each peak extracts the chromatogram at these different wavelengths and displays the apex optimized chromatogram in the pane directly below the sample chromatogram If you are interested in viewing the apex spectrum for a specific peak in the apex optimized chromatogram click on the peak The apex spectrum for the currently selected peak is displayed in th
209. n be added to a spectral library by using the Build Library commands located under the Tools menu For more information on setting up a library of stored spectra refer to the Spectral Libraries chapter on page 151 76 Chapter 4 Viewing Spectra Viewing a Spectrum This section shows you how to open and view chromatographic spectra and individual spectrums that have been previously extracted and saved using the File gt Save As command in IRIS Previously stored individual spectrums can be opened and viewed on the Main View Chrom Spectra View and the Compare View Meanwhile spectra associated with a chromatogram are accessed from the chromatogram You can view the spectra in a chromatogram from the Main View Chrom Spectra View Spectra 3D View Contour Map View and Compare View 77 Iris HPLC Spectral Processing Software Viewing Chromatographic Spectra In this section you will learn how to capture and display a spectrum from a chromatogram in a chromatogram pane contour map or 3D plot pane using the Main View For more information on extracting spectra using the other View pages in IRIS refer to the chapter titled Chapter 5 Viewing the Data Note A captured spectrum is a spectrum extracted from its source and displayed permanently in the Spectra Pane A captured spectrum can be hidden and or removed How do I see spectra associated with a chromatogram IRIS also allows you to see spectra associated
210. n command located in the File menu to obtain additional information on a stored spectrum that is not open Or you can also view information about a spectrum that is listed on the Data Tree by right mouse clicking on the spectrum and selecting Information from the context menu that appears Note Ifyou are viewing Information on spectra created via a mathematical operation in IRIS the details of the operation and the source of the spectra will be included on the Information dialog If you are viewing Information on spectra extracted from chromatograms the source of the spectra is shown on the Information dialog along with the baseline source and type single point peak start interpolated etc To view information about a spectrum without opening the spectral file 1 From the File menu select Information gt Spectrum The Open Spectrum dialog appears 2 From this Open dialog select the spectral file UV that contains the spectrum that you wish to view more information on and click Open The Information dialog box for the selected spectrum appears Spectrum Information 3 417 ciprogram filesiperkinelmer instrumentsirisidal ciprogram filesiperkinelmer instrumentsirisidal 06 01 2006 10 29 42 AM Eastern Standard Time 3 manager Baseline Corrected No Baseline Rt Time 3 315 Baseline Mode Peak Start Only Add Comment Include Timestamp Add Cancel Figure 4 3 Information dialog for a previously saved spect
211. n the Standard Chromatogram button located on the Parameters pane to select the standard chromatogram Once you have selected a standard chromatogram you are returned to the Spectral Standard Confirmation operation and the standard chromatogram appears on the Standard Chromatogram pane with a vertical cursor that snaps to the nearest peak that corresponds to the peak selected on the Sample Chromatogram pane The results of the operation are displayed in the lower Results pane In addition the peaks in the sample chromatogram are labeled accordingly peaks in the sample that correspond to a peak in the standard are labeled with the Absorbance Index value while peaks in the sample chromatogram that do not have a corresponding peak in the standard are labeled with Not found To view the Spectral Standard Confirmation plot for a different peak gt Select the required peak by clicking on it in the sample chromatogram The Results pane is updated to show the peak apex spectrum for the peak selected on the sample chromatogram and the peak apex spectrum for the peak selected on the standard chromatogram the Spectral Standard Confirmation plot the Absorbance Index value and optionally the baseline spectrum for the selected peaks on the sample chromatogram and standard chromatogram 247 Iris HPLC Spectral Processing Software To examine the Spectral Standard Confirmation values at different wavelengths gt Enter a new value for
212. n the sample chromatogram that are not present in the standard chromatogram 237 Iris HPLC Spectral Processing Software Tell me about the Spectral Standard Confirmation operation The Spectral Standard Confirmation operation is comprised of the following areas Views Tree The Views Tree provides you access to the Spectral Standard Confirmation operation To access this operation expand the Operations node and click on Spectral Standard Confirmation Spectral Math Peak Purty Absorbance Ratio Wavelength Maxum Spectral Randerd Contin Spectral Ute ary Cortina 238 Chapter 8 Performing Operations on Chromatograms e Data Tree The Data Tree displays a list of currently loaded chromatograms You use the Data Tree to select the chromatograms that you want to use in the operation The chromatogram you select from the Data Tree is displayed in the upper pane Chromatogram pane for this operation Note If the selected chromatogram has no named peaks then a message Is displayed on the Chromatogram pane that states Selected chromatogram has no named peaks and the Standard Chromatogram pane and Results pane are blank 239 Iris 240 HPLC Spectral Processing Software Sample Chromatogram Pane This pane displays the chromatogram that you selected from the Data Tree When a chromatogram is first displayed on this pane the first peak is selected and appears highlighted in pale green You can select any n
213. ndard C IV Baseline Corect Spectra Spectral Library Cor Peak Library Search Library List Retention Time Adjt Extract Chromatogr Apex Optimized Chr LEEN TEELE UU PU TIZEN LEEN EIERN ILEN LEREN IEEE IU Ue I Uo GO ELLEI Custom Views 05 4 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 Minimum Wavelength 199 7 Benzene 0 yl Benzene 0 Propyl Benzene 0 017 Component igi Adjusted RT Benzene A 1 87 Toluene A 2 62 Ethyl Benzene 3 75 oe 1 identified z Propyl Benzene 3 5 33 Butyl Benzene Display M pex O Spectrum Baseline pees pe per peep A Library 200 225 250 275 300 325 350 375 ac El Library Baseline Login manager amp 4 Figure 8 7 The Retention Time Adjustment operation 276 Chapter 8 Performing Operations on Chromatograms When should I use this operation This operation is useful because TotalChrom identifies a peak because it falls within a retention time window and if the peak moves outside that window then TotalChrom can no longer identify it Therefore this operation allows you to identify the peaks even when they move outside the retention time window In addition you may want to perform this operation if the chromatography and or column have changed when applying an existing method In addition this operation can be particularly useful during the method development or method robustness phases in any applications lab This operation can also be helpful when performing me
214. nding entry codes see the table below When the program is executed by TotalChrom during an active sequence or Batch operation RST will prompt TotalChrom to pass the name and path of the current result file to AutoCalc From the current result file IRIS determines the name and path of the TotalChrom processing method used to create it Note The following format must be used when specifying which operations you wish to run in conjunction with an analysis SRST run X Y Z Where X Y Z represent various operations you can specify 318 Following is a list of the o erations ou can speci Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Conformation Spectral Library Conformation Retention Time Adjustment Library Match Extract Chromatograms Print Apex Spectra with chromatogram Spectra are not baseline corrected Note For more information on using this command see page320 Executes all available calculations Chapter 9 AutoCalc Automating Arithmetic Operations Extractions and Apex Spectra Printing 5 From the Execute after drop down select Quantitation 6 Click OK when finished 7 Save the method Now that you have saved the method AutoCalc will be invoked for any sequence that is run which uses this method Command Line Examples Following is a list of example operations you can specify Command Line Examples Description RST run PT WM Print Command for
215. ndow are used to obtain important information on chromatograms and to help you analyze spectra All of the Views and Operations that can be displayed on the IRIS window are listed on the Views Tree Views When IRIS launches the Main View is displayed by default This view is divided into four panes a Chromatogram pane a Spectra pane a Contour Map and a 3D Plot pane In addition to the Main View IRIS also provides you with four other default views that you can select from the Views Tree The four other default views are labeled Chrom Spectra Contour Map View Spectra 3D View and Compare You can also create your own Custom View by modifying an existing view For more information on Views in IRIS refer to the chapter titled Chapter 5 Viewing the Data on page 105 Operations Operations that you can perform on chromatograms and spectra are listed under the Operations node of the Views Tree The operations listed on the Views tree provide you with a number of options for identifying storing and performing calculations on spectra and for obtaining important information about your chromatograms such as verifying the purity of chromatographic peaks or building your own libraries of stored spectra that can be used in a search to identify an unknown spectrum When you click on an Operation such as Wavelength Maximum the right hand side of the IRIS window displays panes for displaying the required Chromatogram or Spectrum which you
216. njunction with TotalChrom IRIS also contains features and functions to assist laboratories in meeting FDA regulations such as 21 CFR Part 11 by providing electronic records controls and electronic signature support for all data modified or created by the IRIS application This chapter introduces you to the IRIS application and describes how to access the IRIS application In addition this chapter also provides you with an overview of the IRIS user interface and information on concepts you should be familiar with before using IRIS such as how spectral methods are used in IRIS Chapter 1 Introduction About I RIS Spectral Processing Software IRIS Spectral Processing software provides an easy navigation through the wealth of spectral information provided by Photo Diode Array detection With IRIS you can access display and manipulate spectral data with speed and flexibility In addition IRIS provides you with the ability to perform various chromatographic calculations such as confirming and performing peak identification via spectral library matches calculating and reporting peak purity and wavelength maxima for each component You can also use the IRIS software to extract and reprocess actual chromatograms at any wavelength you desire directly from spectral data files One of the benefits you will discover when using IRIS is that the integration between the IRIS Spectral Processing software and TotalChrom allows you to e Easily pass
217. ns Extractions and Apex Spectra Printing Points to consider when using AutoCalc for automated operations in TotalChrom AutoCalc uses the parameter values that are stored in an IRIS Process Spectral Method to perform any of the automated operations described in this chapter Therefore it is important that you understand how to have IRIS automatically generate a Process Spectral Method and then update that method with all of the parameter values that will be used by AutoCalc for automated operations As explained in Chapter 2 Getting Started the Process Spectral Method along with the Chromatogram s Spectral Method is created when a chromatogram is first opened in IRIS The Process Spectral Method is given the same name and stored in the same location as the TotalChrom Method that was used to create the result file that you opened in IRIS however the file extension is tsm instead of mth Although the Process Spectral Method is created upon opening a chromatogram in IRIS for the first time it cannot be used by AutoCalc each operation that you want to automate is first performed in IRIS on a chromatogram that has been processed by the same TotalChrom method that will be used to process the future sequence and the results saved Note All chromatograms that are opened in IRIS and have been processed by the same TotalChrom method share the same Process Spectral Method Following are detailed instructions on how to have IRIS generate a Proc
218. nt to extract The chromatogram at the point you clicked appears in the Chromatogram pane Note Chromatograms that are captured from a Spectra pane are only temporary and will be cleared when you select a different view 117 Iris HPLC Spectral Processing Software How do I temporarily capture a chromatogram from the Contour Map pane On the Main View you can temporarily capture chromatograms from a Contour Map However it is important to note that any chromatograms you capture from the Contour Map pane are temporary and will be cleared from the display when you select a different view To temporarily capture a chromatogram from a Contour Map pane the Chromatogram pane must use an overlaid display and the Contour Map pane must use a stacked display To temporarily extract and display a chromatogram from a point on the Contour Map 1 On the Main View check the chromatogram on the Data Tree that you want displayed as a contour map The chromatogram is displayed on the Chromatogram pane Contour Map pane and 3D Plot pane 2 Make sure that the Chromatogram pane is set to an Overlaid display 3 Float your mouse pointer over a point on the contour map plot to temporarily view in the Chromatogram pane the chromatogram from that point As you continue to float your mouse pointer over the contour map the Chromatogram pane automatically updates so that the chromatogram from the current location of your mouse pointer is displaye
219. ntation as well as the font size and style 3 Make your choices and click OK The text appears on the pane 4 Click and drag the annotation to the exact location you want 5 Click outside the box The text is placed on the screen 6 The text can be selected and moved at any time by clicking on it and dragging 324 Chapter 10 Printing and Presentations How do modify an annotation You can modify the font style and text of any annotation you have placed on the screen by selecting Actions gt Annotations gt Edit from the menu bar To modify an annotation The Edit Annotation command operates only on a selected annotation 1 Select the annotation to be changed by clicking on it The cursor turns into a four way cursor a box appears around the label Select Actions gt Annotations gt Edit from the menu bar The Edit Annotations dialog appears and from this dialog you can change the annotation or its font size and style Click on the Annotation tab to modify the Text and Orientation Click on the Font tab to select a Font Font Size Style Color and to select whether or not the label is underlined This tab page provides you with a preview that shows you the name of the selected font formatted as set on the two tabs and is automatically updated for each selection made on the dialog Once you have finished making your changes click OK The dialogue box is closed and the selected label with the chan
220. o add it to the Libraries list or you can select multiple libraries to add to the Libraries List by using CTRL click or SHIFT click The selected libraries now appear in the Libraries List To remove a library from the Libraries list click on the library and then click Delete The selected library is removed from the Libraries list and reappears in the Available Libraries list Click OK You are returned to the Spectral Library Confirmation operation and each peak that IRIS was able to match is labelled with the identically named spectrum from the spectral library along with the Hit Quality of the match and a Pass Fail flag that indicates whether or not the test passed or failed To add the spectra that are displayed in the Results pane to the Data Tree gt Select Actions gt Add All to View A dialogue box is displayed with the message The data was added successfully On re displaying the Main View or Chrom Spectra View the added spectra will appear in the Data Tree To save the results and parameters used in the calculation 1 Select File gt Save Results A save dialog appears that asks you to confirm whether or not you want to save the new values to the chromatogram s result file RST and save the parameters that were used calculate the results to the associated spectral method file TSM Click Yes to save the results and calculation parameters Spectral Library Confirmation values added to the
221. o be noted that the first spectrum that is always listed on the Hits List is the Sample Spectrum You can check the Sample Spectrum listed here to compare it to matching spectra that are also checked on this list Y kj ig CIE g ti Note Spectra that appear checked on this list can be added to the Data Tree by selecting Actions gt Add All to View 172 Chapter 6 Spectral Libraries Hits Pane The Hits Pane provides a graphical display of the spectra that are checked on the Hits List From this pane you can compare the sample spectrum with selected Hits the spectra that appear on this graph are color coded to match the Hits List Hits E Match Sample Spectrum a o m DIS Propyl Benzene C 0 26 Butyl fenzene m Oy ee ees 385 173 Iris HPLC Spectral Processing Software Summary of Operation Library Match The summary below illustrates how identify a spectrum by matching it to a spectral library or libraries To match a spectrum to one or multiple libraries Note Before you perform the Library Match Operation the spectrum you wish to identify must already be extracted from a chromatogram and displayed on the Data Tree For more information on extracting spectra see page 78 1 From the Views Tree select Operations gt Library Match If you have already selected a spectrum on the Data Tree and a list of libraries has been built prior to you selecting the Library Match page t
222. oftware Range Displays a green range box on the chromatogram This option is not available when the Chromatogram Pane is displayed on an Operations page Add to View Adds the spectrum temporarily displayed from a selected point on the chromatogram to the Data Tree and selects it This option is not available when the Chromatogram Pane is displayed on an Operations page Note To use this option you must have the Chromatogram pane in Stacked mode and the Spectra pane in Overlay mode Format Graphs Displays the Format Graphs dialog at the Chromatogram tab Changes made here effect the current graph only Spectral Baseline Displays the Spectral Baseline Correction dialog Correction 62 Chapter 3 Opening and Viewing Chromatograms Obtaining Information about a Chromatogram There are two ways you can obtain information about a stored chromatogram You can use the Information command located in the File menu to obtain additional information on a stored chromatogram that is not open Or you can also view information about a chromatogram that is listed on the Data Tree by right mouse clicking on the chromatogram and selecting Information from the context menu that appears To view information about a chromatogram without opening the chromatogram 1 From the File menu select Information gt Chromatogram The Open Chromatogram dialog appears Open Chromatogram Look in B Data amp e e By Example 2 Incompl
223. ommand is enabled when a spectrum is selected in the data tree The command does not work if a baseline spectrum is selected 17 Iris HPLC Spectral Processing Software Menu 18 Command v Baseline Corrected Spectra Overlay Chromatograms Stack Spectra v View tree v Data tree v Parameters Description Sets whether or not spectra are displayed as baseline corrected When this command is checked spectra are displayed as baseline corrected Note On individual operations you can check Baseline Corrected to perform the operation using baseline corrected spectra On the other hand the Baseline Corrected Spectra menu command only affects the display of the spectra Enabled at all times Displays the contents of all chromatogram windows with all chromatograms being displayed on the one set of axes When selected the menu item changes to Stack Chromatograms and selecting the option returns all chromatograms to being displayed on separate axes Enabled at all times Displays the contents of all spectral windows split onto separate axes When selected the menu item changes to Overlay Spectra and selecting the option again will return to all spectra being displayed on the one set of axes Enabled at all times Toggles the cross hair cursor Enabled on any of the IRIS views this command is not enabled on operations Toggles whether or not the toolbars are displayed When Toolbars is checked all three tool
224. on the Autoscale Y icon l The absorbance range is scaled such that the lowest absorbance in the displayed data is set to the bottom contour and the top absorbance is set to the top contour 130 Chapter 5 Viewing the Data To return to the full display of the map Use this command to return to the full display of the map 1 Click anywhere on the map _ Click on the Autoscale X and Y icon amp The wavelength and time axes are returned to their full range The absorbance range is scaled such that the lowest absorbance in the displayed data is set to the bottom contour and the top absorbance is set to the top contour How do scale the Time Absorbance and Wavelength axes on the Contour Map To scale the Time Absorbance and Wavelength axes on the Contour Map 1 You can scale all three axes on a Contour Map by right mouse clicking on the Contour Map and selecting Format Graphs from the context menu that appears The Format Graphs window appears with the Contour Map tab selected From this tab page you can scale each of the three regions independently by specifying the limits for the Time Wavelength and Absorbance axes and you can preview the effect of the values you specify for the axes directly on the screen The display shows you how the plot will appear You can hover your mouse over the controls on the tab page to view information about the control After you have specified the limits for all 3 axes click OK
225. ons on Spectra on page 178 and the chapter titled Chapter 8 Performing Operations on Chromatograms on page 199 The Data Tree on page 9 This chapter describes the five default views as well as provides you with information on creating Custom Views 106 Chapter 5 Viewing the Data Main View When you first launch IRIS the Main View is displayed on the IRIS window This view allows you to look at chromatograms and their associated spectra as well as the contour map and 3D plot for a chromatogram Note You can scale each of the four panes that are displayed on the Main View with a wide selection of tools For more information on scaling chromatograms see page 66 For more information on scaling spectra see page 89 For more information on scaling the Contour Map see page 129 For more information on scaling a 3D Plot see page 141 Tell me about the Main View Pi Iris aan Fie Edit Yiew Actions Tools Help j lalalolalal2 Mal Heloo ees Fo f zle uelle l Io lka Main View 3D Views Main View Chrom Spectra Contour Map Spectra3D Compare Operations amp Custom Views Kaa wat van po va waa waaga eae wa apa aa w pe ep aa aoa apo wa waa ge wa wia ia ay a J 11 22 33 44 55 66 77 88 1 1 22 33 44 55 66 77 88 Data M example 2 identified but with coe M2 991 220 275 330 385 Login manager amp Figure 5 1 The Main View is used to display chromatograms spe
226. ontents of the pane that is currently selected When this option is selected the Chromatograms and Spectra tab pages are enabled These tab pages allow you to define how you want the chromatograms and spectra to be presented on the print out Apex Spectra Allows you to print the parent chromatogram and associated apex spectra When this radio button is selected you must also select whether or not you wish to print All of the apex spectra or just the apex spectra from known peaks or to print the apex spectra for spectra that are above the set absorbance limit Note Spectra are always printed over their complete range 190 400 400 700 or 190 700 331 Iris HPLC Spectral Processing Software Chromatograms tab page From the Chromatograms tab page you can select whether or not you want the chromatograms to be printed as overlaid on one plot stacked on one plot or printed on separate plots You can also specify which label will be displayed on the printed chromatograms Curves As View C Overlaid C Stacked C Separate Plots E E Labels As View C Specified Print Cancel Figure 11 5 The Chromatograms tab page is enabled when you select the Selected Pane only radio button on the General tab page and can be used when a Chromatogram pane is selected on the current view 332 Chapter 10 Printing and Presentations The following options are available to you on the Chromatograms tab page Curves From
227. ontinue to float your mouse pointer over the chromatogram the Spectra pane automatically updates so that the spectrum from the current location of your mouse pointer is displayed in the appropriate pane 4 If you see a spectrum that you want extract just double click on the spot in the chromatogram that contains the spectrum you want to extract The spectrum at the wavelength and time you clicked appears in the Spectra pane How do I capture a spectrum from a Contour Map To extract and display a spectrum from a point on the Contour Map 5 On the Main View check the chromatogram on the Data Tree that you want displayed as a contour map The chromatogram is displayed on the Chromatogram pane Contour Map pane and 3D Plot pane 6 Float your mouse pointer over a point on the contour map plot to temporarily view in the Spectra pane the spectrum from that point As you continue to float your mouse pointer over the contour map the Spectra pane automatically updates so that the spectrum from the current location of your mouse pointer is displayed in the appropriate pane 7 If you see a spectrum that you want extract just double click on that area in the contour map and the spectrum at the wavelength and time you clicked appears in the Spectra pane and is now listed on the Data Tree Note Unlike the Main View where extracted spectra are displayed on the Data Tree when you extract a spectrum from the Contour Map View the spectrum
228. operation searches spectral libraries for a match to the apex spectrum of each peak in the chromatogram The comparison of the spectra is made by calculating the Euclidean distance algorithm the numerical result of which is called the Hit Quality The Hit Quality Value or distance between the two spectra can very between 0 and 1 4 The lower the Hit Quality number the closer the spectra and the better the match Note For more information on the Euclidean Distance algorithm refer to Appendix 1 When the Peak Library Search operation is performed and a peak is selected on the chromatogram you will notice that a list of all the library spectra that are considered a match to the peak apex spectrum of the currently selected peak are displayed The library spectra displayed here are considered a match because the distance between these library spectra and the peak apex spectrum for the currently selected peak fall within a user specified Hit Distance Threshold For verification purposes IRIS uses a default Hit Distance Threshold of 0 05 to confirm which peak apex spectrum is the same component as that in the spectral library Therefore when the distance between a sample spectrum and a library spectrum is less than 0 05 IRIS labels the sample peak with the component name of the best matching library spectrum It should be noted that a Hit Quality value higher than 0 05 suggests either the peak in the sample is impure or that it is not the sam
229. or to the bottom of the contour Enabled at all times Returns the selected graph to the previous scaling stepping back one at a time through previous scale changes Enabled only when the selected 2D or 3D graph has been scaled normalized or zoomed Rotate X Sets rotation slider to rotate around the X axis Rotate Y Sets rotation slider to rotate around the Y axis Displays the Label Chromatograms dialog Enabled any time a chromatogram is selected on a View not an Operation Add Opens an empty Edit Annotations dialog Enabled when a graph is selected Edit Opens the Edit Annotations dialog with the details of the selected annotation available to edit Enabled when an annotation is selected Delete Removes the selected annotation Enabled when an annotation is selected Delete All Removes all annotations from the selected graph Enabled when a graph is selected that has at least one annotation Menu Command Range Description Chapter 1 Introduction This command is used to display all the spectra within a given time range When this command is selected a green range box is displayed on the chromatogram e Positioning the mouse pointer in the range box and clicking actives the range box When activated Handles are displayed on the left and right edges of the box Positioning the mouse pointer over the left or right handles of the box changes it to a horizontal two headed arrow and click and hold en
230. ou are finished 340 Chapter 10 Printing and Presentations How do print the contents of a single pane from any of the IRIS views On any of the IRIS views you can select to print only the contents of the currently selected pane If you have selected a Chromatogram pane or a Spectra pane you can define how the contents of the currently selected pane will be printed On the other hand if the pane you have currently selected is a 3D Plot pane or a Contour Map pane the display currently shown on the IRIS window for the selected pane is printed when you select File gt Print and select the Selected Pane Only option on the Print dialog To print the contents of the currently selected pane 1 From the current view select the pane you want to print by clicking anywhere inside the white space of the pane A blue border appears around the selected pane 2 From the IRIS menu bar select File gt Print The Print dialog displays General Printer Adobe PDF x Preferences Orientation Portrait Landscape Print What All Panes In View C Selected Pane Only Apex Spectra 3 Under the Printer drop down menu select a printer 4 Click on the Preferences button to define the settings for the printer 5 Select the Orientation for the print out as either Portrait or Landscape 341 Iris 6 342 HPLC Spectral Processing Software Select Selected Pane Only to print the contents of
231. ound is defined as the ratio of the absorbance at two specified wavelengths in its peak apex spectrum This value is constant for any given component and its value can therefore be used to confirm identification and purity In IRIS you use the Absorbance Ratio operation to optimize adjust the absorbance ratio for each peak in an open and visually selected chromatogram gt To access this operation expand the Operations node on the Views tree and select Absorbance Ratio File Edit View Actions Tools Help siaial olalale mlal Helean eE ol e aL st Wal wa vol wale erie EZ e g ej Absorbance Ratio Sample Absorbance Ratio amp Operations Library Match Wavelength A Spectral Derivative 2 2500 j Spectral Math Peak Purity Absorbance Ratio f Wavelength B Wavelength Maximum 3 250 Spectral Standard Confiri Spectral Library Confirma Peak Library Search 4 Retention Time Adjustme 2 Absorbance Threshold Extract Chromatograms v Auto C Manual B IV Baseline Corect Spectra COR CY CY YT EAA AA 2 2 33 44 5 5 6 6 77 8 8 example1_well_separated001 Ratio A B 0 35 Ure pe Pela nt ert ra Son iota r t Lys onl Str ot nt Wah Ears Fel LL Dea ES Absorbance Ratio 220 275 330 385 Login manager 4 Figure 8 2 The Absorbance Ratio operation 214 Chapter 8 Performing Operations on Chromatograms Determining the Absorbance Ratio for each peak in a chromatogram
232. our Map Or if you want to extract spectra from this pane click on any area inside the white space of the Spectra pane and set the Spectra pane to an overlaid display and then double click on the area in the Contour Map that contains the spectrum you want to extract You can also temporarily view a chromatogram from a point on the contour map To display a chromatogram from a point on a contour map first make sure the Chromatogram pane is set to an overlaid display Then simply float your mouse pointer over the contour map and the chromatogram from that point is temporarily displayed on the Chromatogram pane in the Main View If you want to temporarily capture a chromatogram from this pane first make sure the Chromatogram pane is set to an overlaid display Then double click on an area in the Contour Map pane and the chromatogram at the wavelength and time you clicked appears in the Chromatogram pane Note Chromatograms that are captured from a contour map are only temporary and will be cleared when you leave the Main View For information on capturing chromatograms and spectra from the Contour Map View see page 122 ERE ie lt S 00 Rs xo 376 200 225 250 276 300 ns 0 376 verge 11 22 33 44 65 66 77 8109 112 Chapter 5 Viewing the Data e 3D Plot Pane This pane displays stacked three dimensional perspective plots for each chromatogram that is checked on the Data Tree The stacked plots appear in the sa
233. out Spectral Libraries IRIS provides you with the ability to identify a spectrum by searching one or multiple libraries for a match to an unknown spectrum to build your own libraries of stored spectra build a library directly from the peak apex spectra in a chromatogram as well as browse through the individual spectra in a library and if necessary edit that library This chapter provides you with information on the following topics e Automatically Creating a Library from Named Peaks e Manually Creating a Library e Viewing a Library e Editing a Library e identifying a Spectrum using the Library Match operation 152 Chapter 6 Spectral Libraries Automatically Creating a Library from Named Peaks The Add Apexes command is accessed by selecting Tools gt Build Library gt Add Apexes This command allows you to automatically create a spectral library using the apex spectra from named peaks in a chromatogram This feature is particularly useful when you wish to create a library for use with the Spectral Library Confirmation function since this function requires that the names of the peaks in the chromatogram are identical to the component names in the library Note Ifthe chromatogram you have selected contains no identified peaks an error is displayed that tells you that you cannot add the apex spectra 153 Iris HPLC Spectral Processing Software How do I create a spectral library using the apex spectra from named peaks
234. p view allows you to obtain a plot of spectral data that resembles a geographical contour map except that the lines represent equal absorbance rather than equal altitude The axes for the display are Retention Time and Wavelength The contour levels show the absorbances There are 100 colored levels on the Contour Map The color at each level is fixed starting with blue at the bottom and finishing with white at the top The absorbance range covered can be set using the various scaling commands on the view for more information see the topic titled Scaling a Contour Map on page 129 Tell me about the Contour Map View File Edit View Actions Tools Help saBlelalslaina e fonmesefeol fe al 3 Wel wa bol vl users a h Uee Contour Map View Contour i Views Main view Chrom Spectra Contour Map Spectra3sD Compare Operations Custom Views example 2 identified but with coeluti Us Po CTY LL DO DO avaa anny IMAA 220 275 330 385 14 22 33 44 55 66 77 88 Login manager amp 4 Figure 5 3 The Contour Map View 122 Chapter 5 Viewing the Data The Contour Map View consists of the following areas e Views Tree The Views Tree provides you access to the Contour Map View File Edt View Actions Took Help ene gt af gt Helajanm mA 1 OI o Fe Mol e ut dual ig Belz Contour Map View Contour SERE ggg 11 322 33 44 66 66 77 e
235. peak by clicking on it in the chromatogram The results pane is updated to show the peak apex spectrum the matching library spectrum and optionally the baseline spectrum for the selected peak and the matching library spectrum To examine the Spectral Library Confirmation values at different wavelengths gt Enter a new value for Minimum Wavelength and or Maximum Wavelength The Spectral Library Confirmation value labels are updated for every peak in the chromatogram To examine the effect of using baseline corrected spectra on the Spectral Library Confirmation values gt Check Baseline Correct Spectra The Spectral Library Confirmation value labels are updated for every peak in the chromatogram 260 Chapter 8 Performing Operations on Chromatograms To change the spectral library libraries that are used in the match 1 Select the Library List button The Libraries List dialog appears Specify the directory path where the libraries you wish to search are located by typing the directory path in the Look in text box or by clicking on the Browse button and selecting a directory path from the Browse for Directory dialog box Once you have specified a directory path a list of libraries available for selection appears on the Libraries list dialog From the Available libraries list click on the spectral library libraries you want to use and then click on the Add button You can either click on a single library t
236. pears The selected chromatogram is displayed in the requested environment 73 Chapter 4 Viewing Spectra Chapter 4 Viewing Spectra Introduction Now that you ve opened a chromatogram you can look at its associated spectra You can use the Main View and Chrom Spectra View to open extract and view spectra In this chapter we first describe how spectra are collected for viewing in IRIS In this chapter you will also learn how to examine spectra on the various IRIS Views as well as learn how to modify the spectrum display so that you can more easily compare spectra 75 Iris HPLC Spectral Processing Software Spectral Formats IRIS stores spectra in three different formats chromatographic independent and library spectra Chromatographic Spectra These are the spectra associated with a chromatogram Spectra are collected by the Series 200 Diode Array Detector in equal time increments across the entire chromatogram TotalChrom lets you define the time range and the collection increment i e the spectral collection rate These spectra can be accessed from the chromatogram when the chromatogram is selected on the Data Tree and displayed on the current View To see spectra associated with a chromatogram simply float your mouse pointer over the chromatogram and the spectrum from that point is temporarily displayed on the Spectra pane on the current view We recommend you use the Main View Chrom Spectra View Contour M
237. pectra and Overlay Spectra and determines how the contents of the pane are displayed e The menu command displays Overlay Spectra when the current display is set to Stacked If an overlaid display is selected and all plots are plotted on the same Y scale a single Y scale is shown If each plot is plotted with its own Y scale then the Y axis has no labels e When Stack Spectra is selected all spectra are split onto separate axes and the menu command changes to Overlay Chromatograms Toggles the cross hair cursor Closes the selected pane forming a custom view Displays the Format Graphs dialog at the Spectrum tab Changes made here effect the current graph only Chapter 4 Viewing Spectra How do I capture a spectrum from a Chromatogram pane To view spectra associated with a particular chromatogram as well as extract spectra from a chromatogram the Chromatogram pane must use a Stacked display and the Spectrum pane must use an Overlaid display gt You can set the display modes for both panes by selecting Stack Chromatograms and Overlay Spectra from the View menu To extract spectra 1 Click on any area in the white space of the Chromatogram pane 2 Set the selected Chromatogram pane to Stacked mode by clicking on the icon so x that the icon appears to be pushed down 3 Float your mouse pointer over a point on the chromatogram to temporarily view in the Spectra pane the spectrum from that point As you c
238. pectral Processing Software Results Pane This pane displays a graphical representation of the items that are checked on the Display List You can view Spectrum A Spectrum B and the Result Spectrum on this pane c aT ts GISLI l La amp v aig 2 ajola 196 Chapter 7 Performing Operations on Spectra Summary of Operation Spectral Math The summary below illustrates how to use the Spectral Math operation to perform mathematical operations on any two spectra that are listed on the Data Tree Please note that if you are working with spectra extracted from chromatograms the two spectra must be present in the Data Tree before you access the Spectral Math page Once you have selected the two spectra for the operation IRIS automatically calculates and displays the result of the operation using the parameters currently displayed on the operation You can modify any of the parameters on this page and IRIS will automatically display the new result To select spectra 1 If you are working with spectra extracted from chromatograms the two spectra must be present in the Data Tree prior to displaying the Spectral Math operation From the Views tree expand the Operations node and click on Spectral Math The Spectral Math opeartion displays If you are not working with spectra extracted from chromatograms open one spectrum file at a time using File gt Open gt Spectrum The opened spectra appear in the Data Tree From t
239. ped audit trails for all IRIS files linked to that chromatogram meanwhile all changes made in IRIS to the actual chromatogram are audit trailed by TotalChrom Note Because the TotalChrom chromatographic raw data and the Diode Array spectral file cannot be modified this data is not continuously audit trailed However you can view the name of the user who created the data as well as the creation date by right mouse clicking on a chromatogram or spectral file from the IRIS Data Tree and then selecting Audit Trail from the context menu that appears 45 Iris HPLC Spectral Processing Software What information Is captured in an Audit Trail The following information is captured in the Audit Trail for any file that can be audit trailed New The name of the modified parameter The original value The new value The unambiguous time date stamp of the modification including the Time Zone where the modification occurred The User Name of the person making the change If necessary a selection from the appropriate TotalChrom Reasons List and free text The enforcement of the reason will be based upon settings in the TotalChrom System Configuration files created in IRIS contain the following audit trail information The unambiguous time stamp of the file creation An indication of the source of the new file File filename created as a new file File filename2 created as a Save As from filenamel The User
240. ple 1 identifiec PR Se PENOU P LS FO PETOLE TE 3 200 225 250 275 300 325 350 375 40g Display Sample Spectrum First Derivative Second Derivative Cs PIO ETEN TEN HY E ELEELE PA TOIA I E PELEAN EETL P E E ESL E PERLER T RLETI LIS Y Third Derivative 200 225 250 275 300 325 350 375 400 Fourth Derivative Login manager amp 4 Figure 7 1 The Spectral Derivative operation 179 Iris HPLC Spectral Processing Software Tell me about the Spectral Derivatives operation The Spectral Derivatives operation consists of the following areas e Views Tree This pane provides you access to the Spectral Derivatives operation Magnum Wavelengt ilissa lisy plessatiss Display B Sample Spectrum B First Derivative a ca Fourth Denvative 180 Chapter 7 Performing Operations on Spectra e Data Tree The Data Tree displays a list of extracted spectra that are grouped by their parent chromatogram From the Data Tree you select a spectrum for calculating spectral derivatives Only one spectrum can be selected at a time and the selected spectrum is displayed in the Spectrum Pane As different spectra are selected the software re calculates the derivatives and updates the Derivatives graph Note Ifyou will be performing the Spectral Derivative operation on spectra extracted from a chromatogram the extracted spectra must be displayed on the Data Tree prior to accessing the Spectral Derivate operation Saaga
241. r Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatograrr 3 h Cribar Winnie 2 Data example 2 identified but with coeluti 7 304 7 311 Ono MM 7 319 Tx Display Spectrum A Spectrum B Result 200 225 250 275 300 325 350 375 40g Login manager amp Figure 7 2 The Spectral Math Operation 187 Iris HPLC Spectral Processing Software The Spectral Math operation consists of the following areas e Views Tree This pane provides you access to the Spectral Math operation You can access the Spectral Math operation by selecting Operations gt Spectral Math from the Views Tree A 3 03 Dngtay E Spectrum A B Spectrum i 188 Chapter 7 Performing Operations on Spectra e Data Tree The Data Tree displays a list of extracted spectra that are grouped by their parent chromatogram From the Data Tree you select spectra that will be used to perform mathematical operations on this page You must select two spectra from the Data Tree in order to perform operations on this page For information on selecting spectra see To select spectra on page 197 Note If you will be performing the Spectral Math operation on spectra extracted from a chromatogram the extracted spectra must be displayed on the Data Tree prior to accessing the Spectral Math operation r FEHB p 4 D
242. r more information on using this dialog refer to the chapter titled AutoCalc Automating Chromatographic Tasks Note This command is enabled at all times however in order to access the AutoCalc Print Setup dialog you must first select a chromatogram on the Data Tree that has been processed by the same TotalChrom method that will be used in the sequence Ifa chromatogram is not selected on the Data Tree when you select the AutoCalc Print Setup command the following warning message displays Warning The selected file is not a chromatogram Printing parameters cannot be modified Closes the IRIS application Enabled at all times Copies the selected object to the clipboard If the cursor is in either a chromatogram or spectrum region then the numerical values of that trace will be placed on the clipboard This allows export of data to spreadsheet programs such as Excel Enabled at all times Bitmap Copies the entire screen as a bitmap image to the clipboard Enabled at all times Displays or hides baselines on all chromatograms Baselines are displayed as a solid red line Enabled at all times Adds the baseline spectra for the selected spectra to the Data Tree The baseline spectra are identified by the retention time of the spectrum or if a range of spectra are being used the start and end times of the range followed by the word base and they appear immediately after the parent spectrum in the tree This c
243. ra and tsm for methods Chromatogram When you open rst and uv files they are added to the Data Tree and Spectrum appear selected so that the opened items are immediately displayed in Method the relevant panes in addition to the data that is already displayed in the panes When you open a tsm file a read only version of the Method Editor dialog box appears From this dialog box you can view the parameter values in the method Note about opening files e f the spectral energy of the file being opened is low the Warning Low Energy Spectra dialog appears e f the spectral energy of the file being opened is inconsistent with the associated method the Inconsistent Wavelength Range dialog appears and shows the method s wavelength range and the energy determined wavelength range Inconsistent Wavelength Range s The default method s wavelength range of 230 400nm does not match with this file s actual wavelength range 400 700nm which will be used instead If you click OK on this dialog box the associated method is updated with the actual range shown on the dialog If the checksums are not correct or not present for the TotalChrom raw rst files or the checksum is not correct for the raw spectra file spc a warning is displayed that states Invalid spectral file checksum failed file cannot be opened and the file is not opened If the checksum is not present for the raw spectra file spc a warning is
244. ral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Printing Audit Trail e f you select General from the list box the right hand portion of the dialog lists the date and time when each section of the spectral method was last edited Note Ifthe date time stamp is empty for an operation then this section of the method has never been used When you first use this operation the parameter values will automatically be filled in using the default values that rare stored in the IRIS default method Note Carefully AutoCalc cannot perform an operation if the corresponding section in the method is empty e f you select an operation such as Absorbance Ratio from the list box the right hand portion of the dialog displays the parameter values that are used to calculate the results for that operation e If you select any of the items listed under the Printing node the right hand portion of the dialog displays the default print settings for the spectral method e A Print button that you can select to print a report of the entire spectral method details e An Audit Trail button that you can select to view the audit trail for the spectral method The Audit Trail can also be printed e An Exit button that you select to close the dialog 36 Chapter 1 Introduction How do modify the parameters values stored ina Chro
245. ram in the Library list by component name Enabled only if a single chromatogram is selected and it has named peaks in it Edit Displays a file selector titled Open Library Once you select a library to open the Edit Library dialog appears Enabled at all times Opens the selected TotalChrom application with the selected chromatogram passed to the application Enabled at all times a single chromatogram is selected Menu Help Command Edit Format Graphs Spectral Baseline correction Override save dialog Edit Default Method Contents and Index v Display Tooltips PerkinElmer on the Web Chapter 1 Introduction Description Displays the Audit trail dialog Enabled only when a single chromatogram or spectrum is selected Displays the Format Graphs dialog and either goes to the correct tab for the currently active graph type or the Chromatogram tab if no graph is active Changes made here effect the defaults to change the current graph only use the context menu for the graph Enabled at all times Displays the Spectral Baseline correction dialog Enabled only if a single chromatogram is selected in the Data tree Note This command is also available as context menu for chromatograms only Displays the dialog that enables you to set whether the you want to turn off the automatic save dialog Enabled at all times Displays the Method Editor dialog for the default method enabling it to be edited
246. ration Peak Purity 211 Absorbance Ratio ccseececccaeesecceuneeceeseueeseeseneesesaeneeeetaasessetanseneetes 214 Determining the Absorbance Ratio for each peak in a chromatogram 215 Tell me about the Absorbance Ratio Operation ccecce 216 How do modify the parameters that are used to determine the Absorbance Ratio values eceeeeeeeeeeeeeeeeeee eee aee 222 Summary of Operation Absorbance Ratio 223 Wavelength Maximum eee een EE EEEEEEEEEEEEEEEEEEEEE EEEE EEEE 225 Determining the wavelength maximum of chromatographic peaks 226 Tell me about the Wavelength Maximum operation 0668 227 How do modify the parameters used that are used to determine the Wavelength Maximum values ccecce 233 Summary of Operation Wavelength Maximum sser 234 Spectral Standard Confirmation cccccccccccsssecceceseeeeeesseeeeesssaeeseeaeaes 236 iii Iris HPLC Spectral Processing Software Verifying the Identity of Chromatographic Peaks by Comparing to a Standard Chromatogram ccecescecseseseeeeneeees 237 Tell me about the Spectral Standard Confirmation operation 238 How do modify the parameters that are used to perform the Spectral Standard Confirmation operation 0 245 Summary of Operation Spectral Standard Confirmation 247 Spectral Library Confirmation eect eee e eee tee teeter ee eeeaaaaenees 250 Verifying the Identity of Chromatographic Peaks by Comparin
247. re computer generated time stamped audit trails for all IRIS files linked to that chromatogram In addition Spectral Libraries are always audit trailed All IRIS audit trails can be viewed on screen printed and exported Electronic Signatures In IRIS electronic signatures work in conjunction with audit trailing Electronic Signatures can be enabled in TotalChrom only on files for which audit trail has been enabled The Electronic Signature feature forces a user who saves a file to enter the TotalChrom password that corresponds to the logged on user This chapter covers User Management Audit Trailing and Electronic Signatures 43 Iris HPLC Spectral Processing Software User Management The IRIS Spectral Processing software is designed to be used by several different users who are granted one of three access levels to the application This means that users who are granted one type of access level may perform all IRIS functions while other users who are granted a more restrictive access level can use the software to calculate and save chromatographic results but are not able to perform functions such changing methods or libraries The level of access available to users the IRIS software depends on the permission level you have been assigned to in TotalChrom The TotalChrom Administrator or Lab Manager is responsible for setting up users groups and permissions through the TotalChrom SysConfig utility User Permissions IRIS
248. reated although it does not contain spectra Spectra may be added to the library at any time Therefore you may exit at this point and add the spectra later or you may continue and add any displayed spectra that you want to include in the library The following procedures describe how to create a new library For information on adding deleting or replacing spectra in the library and for information on how to browse the library once spectra have been added see page 162 157 Iris HPLC Spectral Processing Software How do create a new library To create a new library 1 158 From the Tools menu select Build Library gt Create The New Library dialog appears New Library Save in je Iris Soe Recent data B Library G Desktop My Documents My Computer My Network File name Places Save as type Iris Library File alb From the Save in drop down list select the folder where you wish to save the Library you are creating Enter a name for the Library in the Filename field Click Save The Create Library dialog appears Create Library Minimum Wavelength z 190 Maximum Wavelength i i Cancel From the Create Library dialog use either the default values for the Library Minimum and Maximum Wavelengths OR If you are working in a different range enter new Minimum and Maximum Wavelength values that cover the range of spectra collected For example specif
249. ree This Views Tree provides you access to the Extract Chromatograms operation You can access this operation by expanding the Operations node and selecting Extract Chromatograms 292 Chapter 8 Performing Operations on Chromatograms Data Tree The Data Tree displays a list of currently loaded chromatograms You use the Data Tree to select the chromatograms that you want to use in the operation The chromatogram you select from the Data Tree is displayed in the upper pane Chromatogram pane for this operation 293 Iris HPLC Spectral Processing Software e Chromatogram Pane When you select a chromatogram from the Data Tree the selected chromatogram is displayed here To the right of the displayed chromatogram are the parameters under which the chromatogram was originally collected AUAULUORER SAREAUA CGR RON URERIAOGUNOARARO RIG USERINEORS PUN SEL RINE NDS HARARE RIED EEE OAR EEO DYE AE 7 294 Chapter 8 Performing Operations on Chromatograms Extracted Chromatograms Pane Once you have selected a chromatogram from the Data Tree you can use the Extracted Chromatograms pane to view the sample chromatogram at different wavelengths To extract a single chromatogram click on one of the radio buttons located on the top of this pane there are eight radio buttons displayed on the page and then specify the Analytical Wavelength Bandwidth Reference Wavelength and Reference Bandwidth for the chromatogram you want
250. region to be re scaled 2 Click on the Autoscale X and Y icon The wavelength and or time axis will be returned to their full range The Absorbance axis is automatically scaled to fill 80 of the display region 143 Iris HPLC Spectral Processing Software Compare View The Compare View allows you to compare two chromatogram or spectra side by side for easy comparison Tell me about the Compare View Ble Eat View Actions Tools Help RUSS SSNSAyueaem aseleo na A Pesk Purty Absorbance Ratio we Rn ae aay eeapepepenpumpunpenpunpannpanepanpanpanepenepayenseneyt gt 05 115 225336 445 6660057758850 eamp identified and wel 7 4 07 33 Figure 5 5 The Compare View 144 Chapter 5 Viewing the Data The Compare View page is comprised of the following areas e Views Tree The Views Tree provides you access to the Compare View perme rr pos eas eeeees 145 Iris HPLC Spectral Processing Software e Data Trees Both the Data Trees display a list of currently loaded chromatograms and spectra You use the Data Trees to select the chromatograms and spectra that you want to compare side by side in the relevant panes Items that appear checked on the Data Trees are displayed while unchecked items on the Data Trees are not displayed Use Data Tree on the left to check the items that you want displayed in the left hand Chromatogram and Spectra panes Use the Data Tree on the right to check
251. rforming the Extract Chromatograms operation are named with the same name as the original raw file used to perform the operation However the file names for the extracted chromatograms have the following additional information appended to the file name the wavelength collected under the bandwidth the reference wavelength and the reference bandwidth In addition if a file has already been created with the same name IRIS automatically adds the date and time of the newly extracted chromatogram to the RAW and RST files in order to prevent duplicate file names For example In the following example a chromatogram named Example 2 identified but with coelution RST is selected for the operation its raw file is named Example1_coelution raw and the following extraction parameters are specified to produce 1 extracted chromatogram Analytical Wavelength of 260 Bandwidth of 1 Reference Wavelength of 400 Reference Bandwidth of 1 Then selecting File gt Save Results causes IRIS to create the following files Example1_coelution_360_1_400_1 RAW this is the RAW file for the newly extracted chromatogram and Example 2 identified but with coelution 360 1 400_1 RST this is the result file that is automatically created for the newly extracted chromatogram 291 Iris HPLC Spectral Processing Software Tell me about the Extract Chromatograms Operation The Extract Chromatograms operation is comprised of the following areas Views T
252. rom report These results are stored in the Application Value fields in the component list associated with the result file This requires that the peaks in TotalChrom be identified named In addition because these fields can only contain numerical data the IRIS information must sometimes be encoded Listed below is how the IRIS operation saves its information to TotalChrom Note The Save Results dialog appears automatically whenever you have performed an operation on a chromatogram and selected another chromatogram operation or attempt to close the application Peak Purity e Pass results are reported as the normal Purity Index value Failed results are reported as a negative Purity Index e Peaks which are not already identified in TotalChrom and for which the Purity cannot be calculated which are reported as 0 within IRIS are not identified and are never reported within TotalChrom e Peaks which are identified in TotalChrom and for which the Purity cannot be calculated which are reported as 0 within IRIS are reported within TotalChrom with the value 888 Spectral Standard Confirmation e Pass results are reported as the normal Absorbance Index value e Failed results are reported as a negative Absorbance Index e Named peaks in the sample for which no match can be found in the standard reference chromatogram are reported as 999 e Named peaks in the sample for which the Spectral Standard Confirmation cannot be calculated
253. romatograms This is a new chromatogram whose creation does not affect the parent chromatogram result file Retention Time Adjustment e A component in the component list which is in the library and for which a match if found will have the hit value placed in the App Value The value will be negative if the Hit Value is greater than the Hit Distance Threshold e A component in the component list which is not in the library is not reported in the result file e An unidentified peak has no app value associated with it Apex Optimized Chromatogram This is a new chromatogram whose creation does not affect the parent chromatogram result file 311 Iris HPLC Spectral Processing Software How do I include the results of chromatographic operations performed by IRI S AutoCalc in a TotalChrom report Once you have saved the results of an IRIS AutoCalc operation the results can be included in a TotalChrom report For your convenience we have provided you with a report template named AppValues rpt which can be found in the installed example data directory for IRIS This report template includes all of the parameters that you can possibly add from IRIS AutoCalc to a result file However if you do not want to use the AppValues rpt you can also modify the Default Report and add only the IRIS AutoCalc results that you choose to the Default Report template Note For more information on modifying the Default Report refer to the Tot
254. rs are automatically displayed 289 Iris HPLC Spectral Processing Software Extract Chromatograms The Extract Chromatogram operation allows you to extract up to 8 chromatograms from a spectral file and automatically process them gt select Extract Chromatograms File Edit view Actions Tools Help To access this operation expand the Operations node on the IRIS Views tree and S BeelesnazsMl faas mee a mg ei Mrama Ze Extract Chromatograms Sample Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirma Spectral Library Confirmatio Peak Library Search 2 Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogi Custom Views 35 4 45 5 Mi os 1 55 RA IE 20 20 3 a 6 65 X 75 8 5 ELLE CREED ELELE LELAS LELEI RLALS LALLE LELAS ELRLN KLEAN LELAI ELALSLLAAS LELEI LLELE LLELE LELEI ELEAN 9 elength ne Bandwidth 3 a Reference 400 i z sf z Ret Band Method example 2 identified but with coe example 1 identified and well sep B Wavelength po Bandwidth z Reference po Ref Band f Method ex2 identified mth Browse E AAAA BAS DAA RERI DEIRE A RIGA NAASE E a A 0 05E T AS 2 3 4 5 6 7 Figure 8 8 The Extract Chromatograms operation 290 Login manager ay Chapter 8 Performing Operations on Chromato
255. rum 87 Iris HPLC Spectral Processing Software To obtain information about a chromatogram that is listed in the Data Tree gt From the Data Tree right mouse click on a spectrum and select Information from the context menu that appears The Information dialog box for the selected spectrum appears Spectrum Information Retention Time 3 417 c program files perkinelmer instrumentsirisidal c program files perkinelmer instrumentsirisidal 06 01 2006 10 29 42 AM Eastern Standard Time manager Baseline Corrected No Baseline Rt Time 3 315 Baseline Mode Peak Start Only Add Comment V Include Timestamp Add emen Figure 4 4 Information dialog for a spectrum that was selected on the Data Tree 88 Chapter 4 Viewing Spectra Visually Comparing Spectra The default display protocol for spectra displayed in IRIS is an X Y autoscale mode that automatically scales the display so that every spectrum is completely visible in both the X and Y axis directions If you add a new spectrum with a wider range the display s range is adjusted to accommodate it IRIS does however provide you with a number of features that let you modify the spectrum display so that you can more easily compare spectra This section begins with a brief description of the scaling commands available to you and then describes in detail the various forms of spectrum normalization 89 Iris HPLC Spectral Processing Software Opt
256. ry 49 Iris HPLC Spectral Processing Software e When called from the Audit trail button on the Method Editor dialog a Method tab page appears More specifically this dialog appears when you open a Chromatogram s Spectral Method or Process Spectral Method via the File gt Open Method Command then when the Method Editor dialog is displayed click on the Audit Trail button to view the Audit Trail for the Process Spectral Method or Chromatogram s Spectral Method that you selected Method l 01 11 2006 08 40 4M Eastern Standard Time manager Signature Not Required 0111 2006 11 03 AM Eastern Standard Time manager Signature Validated 01 11 2006 04 04 PM Eastern Standard Time manager Signature Validated 01 11 2006 04 04 PM Eastern Standard Time manager Signature Validated 0113 2006 11 29 4M Eastern Standard Time manager Signature Validated Changes made Reason for change File c program files perkinelmer instrumentsris data Initial creation in IRIS example 2 identified but with coelution tsm created automatically as a copy of C Program Files PerkinElmer Instruments Iris Defaut tsm Print Export Loo Figure 2 3 The Audit Trail Reader for a Spectral Method 50 Chapter 2 Enhanced Security e When you right click on a chromatogram in the Data Tree and select Audit Trail from the Context menu the Audit Trail dialog is displayed and consists of two tab pages a Method tab and Spectral
257. s 87 Visually Comparing Spectra eee tne eeee seers naan EEEE Eee 89 Options for Scaling Spectra eee eee ee tree eee enirere 90 Detailed Descriptions of Normalize Buttons 92 Additional Options for Scaling Spectra cceceeeeteeeteeeeeeeeeeeeeeae 100 Saving an Individual Spe CtrUM cee tte ee etter tte eeeeeeeee eae aaties 102 Defining How You are Going to Perform the Baseline Correction of the Spectra eceeceeeccsteteeeeeeeeeeeaeaateeeeeeeseeeaaaaanees 103 Chapter 5 Viewing the Data csssceeecsesseeeeeeseeeeeeeeseeeeeeneneneeneee 105 IRIS VIEWS E E ee sais Sart te catatonia 106 Main VIEW asco olt tied sche nbd ane da aa a T es 107 Tell me about the Main VieW cee eeee tees eet eeeeeeeeeaeeaa 107 How do adjust the pane width and height eeeeee eee 114 How do I open and display chromatograms ceeceeeeeeeeeeees 114 How do open a previously stored individual spectrum 0006 115 How do capture a spectrum from the Chromatogram pane 115 How do capture a spectrum from the Contour Map pane 116 How do capture a spectrum from the 3D Plot pane cccccseeeees 116 How do temporarily capture a chromatogram from the Spectra pane cece cceeee eee e ae teneeeeeeeeeeaeaa aaa eeeeeeeeeaaeaa 117 How do temporarily capture a chromatogram from the Contour Map pane ccceeceeeceeeeeeeeeeeee eee tteeeeeeeeeeaeeaa 118 How do
258. s basically a vector product correlation calculation If S is an array of absorbances for the unknown sample and L is an array of a spectrum in a library the HQI Hit Quality Index for the Euclidean Distance method is calculated by HQI sqrt 2 sqrt 1 sum S L sum S S sum L L The sum S S etc items indicate a dot product operation The dot product operation results in a single value that is the sum of the multiplication of two vectors arrays Once additional note is that both the sample S and library L spectra are normalized to have a minimum value of zero 0 and a maximum value of one 1 before the HQI calculation As you can see if the S and L vectors are identical the algebra works out to give an HQI of zero 0 indicating a perfect match If the S and L vectors are exact antispectra then the HQI will return the maximum allowed value of sqrt 2 which is 1 414 In practice neither of these cases ever happens Basically the smaller the HQI the better the match One thing to remember about searching is that although you will always get a hit list this does not mean that the hit with the lowest HQI in the list is the actual compound you measured It only means it is the most similar one in the library Unfortunately there is no statistical significance or cutoff level that can be assigned to the HQI to determine whether you actually have the same compound as the library spectrum In other words
259. s comprised of the following areas Views Tree The Views Tree provides you access to the Spectra 3D View a Fie Edt View Actions Tools Heb 2 a 3 Ola le 2 Mole Heljan aasar o ESAERAN S A a ___ Cle hed eels m m tenia 11 22 33 44 66 66 77 68 Logn manager amp 133 Iris HPLC Spectral Processing Software Data Tree The Data Tree displays a list of opened chromatograms From the Data Tree you select the required chromatogram for 3D plot Only one chromatogram can be selected and displayed on this view at a time Edt View Actions Took Heb 6 3 3 0 8 6 2 0 oie Helaj a eae oO Custom Views a d Sn ae ap an ae pn amn my e ae yo am aen poe ms ap me ome pa aeg lal 11 22 33 44 66 66 77 68 Loginmanag 134 Chapter 5 Viewing the Data 3D Plot Pane This pane displays the Spectra 3D View from the chromatogram selected on the Data Tree The display includes a crosshair cursor which is used to select a point on either the retention time axis or the wavelength axis and the relevant chromatogram or spectrum will be shown in the corresponding panes below 135 Iris HPLC Spectral Processing Software e Chromatogram Pane The Chromatogram pane displays the chromatogram from the wavelength axis point selected on the 3D Plot pane To display a chromatogram on this pane simply float your mouse pointer over the 3D Plot and the chromatogram fro
260. s how to determine the Wavelength Maximum for all the peaks in a chromatogram and then save the new results and parameters used in the operation To determine the Wavelength Maximum of all the peaks in a chromatogram 1 From the Views Tree expand the Operations node and click on Wavelength Maximum The Wavelength Maximum operation displays 2 If necessary open the required chromatogram using File gt Open gt Chromatogram 3 Select a chromatogram from the Data Tree The selected chromatogram is displayed The first peak is selected The results pane located directly below the chromatogram shows for the selected peak its peak apex spectrum annotated with the position and absorbance of the wavelength maximum and optionally its baseline spectrum In the top right corner of the pane the Wavlength Maximum value is displayed To view the Wavelength Maximum for a different peak gt Select the required peak by clicking on it in the chromatogram The results pane is updated to show the peak apex spectrum the Wavlength Maximum value and optionally the baseline spectrum for the selected peak To examine the Wavelength Maximum values at different wavelengths gt Enter a new value for the Minimum Wavelength and or Maximum Wavelength The Wavelength Maximum value labels are updated for every peak in the chromatogram To examine the effect of using baseline corrected spectra on the Wavelength Maximum values gt Check Ba
261. s the same name as the chromatogram s result file however the file extension is tsm Fore more information on spectral method s see page Error Bookmark not defined Opens the TotalChrom Reprocess or Graphic Method Edit application with the selected chromatogram passed to the application Enabled if a chromatogram is right clicked on 13 Iris HPLC Spectral Processing Software Panes for Displaying Chromatograms Spectra Contour Maps and 3D Plots The right hand side of the IRIS window can consist of multiple panes for displaying chromatograms and spectra The type of panes displayed on the right hand side of the IRIS window depends on whether you are looking at a View or an Operation The screen below shows the panes that are displayed when the Main View is selected on the Views Tree In the Main View you can display chromatograms spectra contour maps and 3D plots prenpanspanqnanqacayennqecogt 1 12 23 34 46 56 67 788 TTT POLLO pranan jn 220 275 330 385 Figure 1 4 The Main View consists of four panes a Chromatogram pane Spectra pane Contour Map pane and a 3D Plot pane gt The Main View Chrom Spectra View Contour Map View Spectra 3D View and Compare View have a predefined set of panes for displaying chromatographic data You cannot add panes to these predefined Views However you can hide a pane that is associated with the view in order to create a Custom View Detailed information on each
262. seline Correct Spectra The Wavelength Maximum value labels are updated for every peak in the chromatogram To change the minimum absorbance value that is used to determine the Wavelength Maximum values 1 Select the Manual radio button The minimum absorbance spin box is enabled 2 Use the spin box to specify a new minimum absorbance value The Wavelength Maximum value labels are updated for every peak in the chromatogram 234 Chapter 8 Performing Operations on Chromatograms To return to automatically calculating the minimum absorbance value gt Select the Auto radio button if you wish to have IRIS automatically calculate the minimum absorbance value that can be used in the calculation The Wavelength Maximum value labels are updated for every peak in the chromatogram To add the displayed spectra in the results pane to the Data Tree gt Select Actions gt Add All to View A dialogue box is be displayed with the message The data was added successfully On re displaying the Main View or Chrom Spectra View the added spectra will apear in the Data Tree To save the results and parameters used in the calculation 1 Select File gt Save Results A save dialog appears that asks you to confirm whether or not you want to save the new values to the chromatogram s result file RST and save the parameters that were used calculate the results to the associated spectral method file TSM 2 To only save re
263. sentations Printing and Presentation Options IRIS lets you easily create high quality presentation output This chapter shows you how to e Add your own annotations to IRIS views e Copy chromatograms and spectra to other programs e Print chromatograms and spectra at high resolution and in color 323 Iris HPLC Spectral Processing Software Annotations IRIS allows you to create freehand labels in any view page and then print the annotated view at high resolution The annotations are free floating text and are not associated with a specific position on a chromatogram or spectrum If you annotate a specific point on a chromatogram and then change the scaling the annotation will not move its position relative to the left and top edges of the pane Note It should be noted that annotations are associated with a pane annotations on a chromatogram are not associated with that chromatogram For example annotations on a chromatogram pane in the Chrom Spectra View will not be displayed in the any other view n addition when you leave a view any annotations you had placed on a pane in that view are cleared How do add an annotation To create freehand labels in any view 1 Click on the pane where you want to add an annotation 2 From the menu bar select Actions gt Annotations gt Add The Edit Annotations dialog appears From this dialog you enter the text of the annotation and specify the text color justification and orie
264. sidered a match Baseline corrected Check this option if you wish to use baseline corrected spectra for the spectral matching Library list Select this command button to display the Libraries List dialog 286 Chapter 8 Performing Operations on Chromatograms Summary of Operation Retention Time Adjustment The following procedure shows you how to correct component retention times and save the results To correct component retention times Note Itis not necessary that the chromatographic peaks in TotalChrom are recognized as labeled components or lie within component tolerance windows nor is it even necessary that the peak are properly identified It is only necessary that these components exist in the chromatogram s embedded method file embedded in the chromatogram s result file Note For this operation to be successful it is important that the component names as labeled by TotalChrom in the chromatogram s embedded method are spelled exactly as those components listed in the selected spectral libraries This includes any spacing or hyphens 1 First open the desired chromatogram in IRIS and select Retention Time Adjustment The Retention Time Adjustment operation displays 2 Click on the Library List button The Libraries List dialog appears 3 From the Libraries List dialog choose any number of spectral libraries to use for matching 4 Click OK 287 Iris HPLC Spectral Processing Software 5 You
265. spectra for spectra that are above the set absorbance limit Note Spectra are always printed over their complete range 190 400 400 700 or 190 700 5 When you have finished defining the print output click Print A report similar to the screen shown below is generated Operation Apex Spectra Sample euerpile 1 identified and well separeted rst Path cc wis dsta data dats aate 07 21 2006 01 16 33 AM Eastern Standard Time manege 12 E gurp Peak 4 Loan Tokens Peak S 2 Seum Oy aaa Aak amp Loten Prapy Renee 348 Appendix 1 Calculation Algorithms Iris HPLC Spectral Processing Software Calculation Algorithms This Appendix includes information on two major calculation algorithms used in IRIS e IRIS Purity Algorithm e Euclidean Distance Algorithm IRIS Peak Purity Algorithn If a chromatographic peak is homogeneous then the spectra on the leading edge of the peak should be identical to those on the trailing edge If however two or more components are eluting in a single peak envelope then as long as the two components do not have the identical retention time the leading edge of the peak will have a higher concentration of the faster eluting component Spectra from the leading edge will differ from those on the trailing edge You therefore can check the homogeneity or purity of a peak by comparing the spectra from its front and back edge Spectra taken close to the peak start wi
266. st Audit Trail manager Aud Trad Evert Time 06 04 2005 02 48PM c program ties perkinelner instrurnerts ris Watalex1 tsm Correction tor aging column Adjustments for mobile phase preperatioin difference Adjustment for laboratory temperature Adding IRIS spectral analysis information to resuf file purty calculation 2 Enter any information about the change s you made to the file in the Comment text box 3 Click OK If Electronic Signatures is enabled the Electronic Signature dialog appears Electronic Signature User Name m Password m Cancel 4 Enter your TotalChrom User Name and Password 5 Click OK 47 Iris HPLC Spectral Processing Software Viewing an Audit Trail All audit trailed files in IRIS can be viewed from an Audit Trail reader You can view the Audit Trail for e A Chromatogram s Spectral Method tsm and Spectral file spc e The default method for IRIS Default tsm or a Process spectral method tsm method associated with all chromatograms that are processed by the same TotalChrom method e A spectral library Note For more information on spectral methods refer to page Error Bookmark not defined The following section describes how to access the audit trail for a particular file as well as describes the components of the Audit Trail reader Audit Trail Methad Spectral 01 11 2006 08 40 AM Eastern Standard Time manager Signature Not Required
267. sted on the Wavelength Maximum operation and IRIS automatically updates the display with the new results Below is a list of the parameters you can modify Parameter Description Minimum Wavelength You can use the spin box to specify the minimum wavelength for the determination of the Wavelength Maximum Maximum You can use the spin box to set the upper limit of the spectrum Wavelength range to be included in the calculation Baseline correct Check this option to use the baseline corrected spectra in the spectra calculation Absorbance Threshold To ensure that IRIS determines the Wavelength Maximum values for small peaks but does not interpret baseline noise as peaks you can use this parameter to set the minimum absorbance values above the system noise and therefore obtain more reproducible results e When Auto is selected the absorbance threshold values are calculated automatically by the system and are set to either 0 0005 A U or 2 of the maximum absorbance in the spectrum whichever is greater The entry field is greyed when Auto is selected When Manual is selected enter the required value in the entry field by either typing directly or using the spin buttons When Manual is first selected the minimum absorbance value calculated by the Auto function is displayed in the Manual threshold field 233 Iris HPLC Spectral Processing Software Summary of Operation Wavelength Maximum The summary below illustrate
268. stom Views 2 904 M2911 M2919 M2926 2 933 2 241 Sanas P E E E ENE a E E a A v 2 J 2977 a py haa 225 250 275 300 325 350 375 Login manager amp Figure 4 6 Range Spectra display after the Normalize X and Y command has been applied 93 Iris HPLC Spectral Processing Software Normalize Y Only The Normalize Y Only command works like the Normalize X and Y command except that it leaves the X axis unchanged and rescales only the Y axis In the example below four spectra were captured from four different peaks Toluene Ethyl Benzene Propyl Benzene and Butyl Benzene Because of the high absorbance in the low UV of the spectra shown in the figure below it is very difficult to see any subtle differences in the higher part of the UV spectrum File Edit View Actions Tools Help aiala ojalale miS 2 44 falaie eE o Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views Propyl Benzene Butyl Benzene M example 1 identified and well sep 1 665 537 M 3 637 Msi ist pata he Se tl a ee a el et 250 40 Login manager amp Figure 4 7 Before applying the Normalize Y only command it is difficult to see any subtle differences in the higher part of the UV spectrum 94 Chapter 4 Viewing Spectra To better compare the spectra we can zoom into this region and then apply the Normalize Y Only command S Iris CES File Edi
269. strumentstiris data Examplet _coelutic User name unavailable 01 04 2006 09 20 50 Number of Spectra 1287 Method c program files perkinelmer instruments iris data ex1 identified mth Figure 3 4 Chromatogram nformation 64 Chapter 3 Opening and Viewing Chromatograms Labeling Chromatograms IRIS provides you with the ability to label individual chromatographic peaks There are 14 different labels available for annotating the chromatograms Only one type of label can displayed at a time You may change the type of labeling on one or all of the chromatograms any time you are viewing chromatograms You cannot apply a label to a chromatogram from an Operations page How do apply a label to chromatograms Note Labels can only be applied to chromatograms that are displayed on a View When you are viewing an Operation you cannot select a label for a chromatogram You can apply labels to all chromatograms that appear in a Chromatogram pane Or if you are looking at a View where the Chromatogram panes are stacked you can apply a label to a single chromatogram To apply a label to all currently loaded chromatograms 1 2 3 4 5 Select a view from the Views Tree Select Actions gt Label Chromatograms The Label Chromatograms dialog appears From the Label drop down select a label you wish to apply Check Apply to all chromatograms Click OK to close the Label Chromatograms dialog To apply a lab
270. sults for peaks that are currently identified named in TotalChrom select Currently identified peaks OR To save results for all peaks select Include unidentified peaks Any unidentified peaks for which results have been calculated are added to the TotalChrom result file as Unknown 1 Unknown 2 etc Any unidentified peaks which do not have results are not added to the file 3 Click Yes to save the results and calculation parameters The Wavlength Maximum values are added to the result file for all identified peaks To display the Wavelength Maximum results in the Main or Chrom Spectra view 1 Select Actions gt Label Chromatograms 2 Select Wavelength Maximum from the list of available labels To review for any chromatogram previously determined Wavelength Maximum values and the parameters used gt Select this chromatogram again on the Wavelength Maximum operation The saved results and the calculation parameters are automatically displayed 235 Iris HPLC Spectral Processing Software Spectral Standard Confirmation The Spectral Standard Confirmation operation allows you to verify the identity of named peaks in a sample chromatogram by comparing the apex spectrum of each peak in the sample to the apex spectrum of an identically named peak in a standard chromatogram The comparison is made using the Absorbance Index test The Absorbance Index is a numerical measure of the similarity of two spectra The value is cal
271. t 218 Chapter 8 Performing Operations on Chromatograms Parameters Pane This pane is where you set and investigate the various parameters used to calculate the Absorbance Ratio values Whenever you change a parameter displayed on this operation and have a chromatogram selected on the Data Tree IRIS automatically updates the Display List and Results pane with the modified results 219 Iris HPLC Spectral Processing Software e Display List You use the Display List to select the information you want displayed on the Results Pane When items appear checked on this list they are displayed in the Results Pane Meanwhile unchecked items are not displayed The following items are available for selection on the Display List Apex Check this option to display the apex spectrum from the currently selected peak on the Results pane Baseline Check this option to display baseline spectrum associated with the currently selected peak on the Results pane Absorbance Ratio This option is only available when Apex is checked When Absorbance Ratio is checked the apex spectrum currently displayed in the Results pane is annotated with the position of the two wavelengths and the absorbances used for calculating the Absorbance Ratio Note You can select Actions gt Add All to View to add all selected spectra in the Display list to the Data Tree 220 Chapter 8 Performing Operations on Chromatograms Res
272. t Each hit is listed by the Hit Quality value and component name You can right mouse click on a hit and select Properties from the context menu that appears to display additional information about the spectrum 00 07 Propyttenzene oOo 07 Tolvene Chapter 8 Performing Operations on Chromatograms Results Pane The Results pane displays the items that are checked on the Hits List You can use this pane to compare how close the apex spectrum of the currently selected peak matches to the hits returned from the search Fie fdt Wew Actons Took Heb S 8 3 0 8412 OM SJ gt Helsonia w o eles Fest eur ala epfca a mi Peoh Linay Sowth Lirary Match Spextral Derevateve Spectral Math Poak Purty Absorbance Raho Warveinagh Marna Moma w armiengh 230 24 Mapam Wareiongh 400 Sort a Standard Contes Spectral Ler ory Cordana Motch Retention Tene Window Posh Lirary Search etendon Tene Adpstme Extract Chromefogams w gt Av thvacene namot 4 t L 4 Aa On AA AANE Aas s pare tee gee MANU nat 271 Iris HPLC Spectral Processing Software How do I modify the parameters used in the search The Parameters pane displays the values that are currently used in the search At any time you can modify the parameters that are listed on the Peak Library Search Page and IRIS automatically updates t
273. t Yiew Actions Tools Help sia lelalele mala ulaferaie ale lose ol a ele fjeki Chrom Spectra View Spectra Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views Propyl Benzene Butyl Benzene Anthracene AN EANN a EENE ENEN ENE YENNY ENEN NE ENEE EENE YEE EEE yEyE 05 4 15 2 25 3 35 4 45 5 55 6 6 5 7 75 8 85 9 M example 1 identified and well sep rane 2 537 3 637 Ms AEAT Gal Ran oj LS em et Eat ok bat on GOR GSE ak ay Sols ptt ck alg Pee oct E Bet PM RL ae yk Wk a On te et D 275 280 295 300 305 Login manager_ amp Figure 4 8 Figure showing the results after zooming into the region of interest 95 Iris HPLC Spectral Processing Software Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views Propyl Benzene Butyl Benzene CO EENN ENEKEN EENE EEEN VEVEY ENEN EENEN EEEE LRR ERE O Wp SEN Neel Use EEA RSL Qk WUT og gir ct op Se aL oo ft Ett ry Fat Ut ay BN oe gt GL tt P 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 Login manager amp Figure 4 9 Figure after the Normalize Y command has been applied As shown in the figure above the spectra are not identical Since the spectra were all captured from different peaks the results shown in the figure above are expected however by using the Normalize Y
274. t are used in the calculation of Peak Purity The Peak Purity operation is very sensitive and two spectra are rarely absolutely identical We have found in practice that a value between 1 00 and 1 50 will usually indicate that the spectra are the same and that the peak is pure However two practical factors have to be considered when actually performing the Peak Purity operation The first is that a result of dividing two noisy numbers close to zero is very unstable and could easily affect the minimum or maximum value in the final calculation To avoid such errors you can set the Absorbance Threshold above the system noise Absorbances in the spectra that fall below this threshold are not used in the calculation The second factor results from the threshold just described Clearly the threshold removes some data points from the calculation It is possible for low absorbance spectra especially if the minimum and maximum wavelength has to be set to a narrow range to have insufficient points for a valid calculation to be performed A second threshold the Minimum Data Points threshold is therefore applied which determines if the calculation can be performed This value defaults to 20 within IRIS but it can be changed 1 Select the Manual radio button The Manual spin box is enabled 2 Use the spin box to specify a new minimum absorbance value The Peak Purity value labels are updated for every peak in the chromatogram If you set the Absor
275. ta Tree gt From the menu bar select Actions gt Add all to View The Result Spectrum is added to the Data Tree To save a result spectrum to a uv file 1 From the Data Tree select the spectrum you wish to save 2 From the File menu select Save As The Save Spectrum As dialog appears 3 Specify a filename and location for the spectral file 198 Chapter amp Performing Operations on Chromatograms Iris HPLC Spectral Processing Software Performing Chromatogram Operations IRIS has a number of built in functions that allow you to obtain important information about your chromatograms These functions include Peak Purity which checks the homogeneity of each peak in the chromatogram Peak Library Search which identifies each peak in the chromatogram by comparing its spectrum to a spectral library and Spectral Standard Confirmation which confirms the identity of each peak in the chromatogram by comparing its spectrum to the spectrum from the same named peak in a reference chromatogram This chapter shows you how to use IRIS to perform operations such as peak Purity and Peak Library Search to investigate a chromatogram More specifically in this chapter you will learn how to e Use the Peak Purity operation to check the purity of chromatographic peaks e Use the Absorbance Ratio operation to calculate the Absorbance Ratio of chromatographic peaks e Use the Wavelength Maximum operation to determine the Wavelengt
276. tcut to your Windows Desktop you can double click on the IRIS icon i gt If TotalChrom is not running you will be prompted with the TotalChrom log on screen From the log on screen enter your Totalchrom User Name and Password OR gt Ifyou have already logged into the TotalChrom application you will not need to log on to TotalChrom again to start IRIS Instead IRIS will open immediately when you start IRIS from Windows To start IRIS directly from Windows 1 From the Windows Start menu select All Programs gt PerkinElmer gt IRIS The IRIS menu displays 2 From the IRIS menu click on IRIS If you have not already logged into TotalChrom the TotalChrom log on dialog appears From the TotalChrom log on dialog enter your TotalCchrom User Name and Password can click OK The IRIS application launches OR If you have already logged into TotalChrom the IRIS application launches Iris HPLC Spectral Processing Software Starting IRIS from TotalChrom There are two ways to start IRIS from TotalChrom from the IRIS icon on the Navigator screen or from a menu command in Reprocess Starting IRIS from the TotalChrom Navigator gt You can start IRIS directly from the TotalChrom Navigator by clicking on the Spectra mn wy icon Spectra Note The Spectra icon is active whenever an instrument containing a Series 200 DAD has been selected Starting IRIS from Reprocess Note Before you can start IRIS from Reproc
277. the pane that is currently selected When this option is selected the Chromatograms and Spectra tab pages are enabled These tab pages allow you to define how you want the chromatograms and spectra to appear on the printnout if a Chromatogram pane or Spectra pane is the currently selected pane If a Chromatogram pane is currently selected click on the Chromatograms tab page and skip to the section titled 7o define the format for printing the currently selected chromatogram pane page 343 OR If a Spectra pane is currently selected click on the Spectra tab page and skip to the section titled 7o define the format for printing the currently selected spectra panen page 344 OR If a Contour Map pane or 3D Plot pane is selected click on the Print button to print the current display for the selected pane Chapter 10 Printing and Presentations To define the format for printing the currently selected chromatogram pane This section applies only to views where a chromatogram pane is currently selected 1 From the current view click on the Chromatogram pane that contains the chromatograms that you want to print 2 Click File gt Print The Print dialog displays Chromatograms Spectra Printer Adobe PDF x Preferences Orientation Portrait Landscape Print What C All Panes In View Selected Pane Only C Apex Spectra Print Cancel 343 Iris HPLC Spectral Processing Softwar
278. thod validation on older columns Assigning a Component Name to a Peak and Correcting the Retention Time in the Chromatograms Result File For this operation IRIS uses the component list the list of components that you are looking for in the chromatogram present in the result file For each component the operation finds the spectrum in the library matching the component name and then finds which peak in the chromatogram best matches that named spectrum If you so choose the retention times in the component list can then be updated with the new retention times and the chromatogram re identified by TotalChrom File gt Save Results Note Ifin reassigning the retention times two peaks have changed their elution order this update process cannot be completed and an error message will appear informing you of this situation 277 Iris HPLC Spectral Processing Software Tell me about the Retention Time Adjustment operation The Retention Time Adjustment operation is comprised of the following areas e Views Tree The Views Tree provides you access to the Retention Time Adjustment operation You can access this operation by expanding the Operations node and selecting Retention Time Adjustment 278 Chapter 8 Performing Operations on Chromatograms Data Tree The Data Tree shows a list of opened chromatograms and is used to select the required chromatogram from the ones available The selected chromatogram is displ
279. tion the Results pane directly below the chromatogram shows for the selected peak the apex spectrum of the peak and optionally its baseline spectrum The spectrum from the library with the lowest Hit Quality is also displayed in the Results pane To view the Peak Library Search values for a different peak gt Select the required peak by clicking on it in the chromatogram The Results pane is updated to show the peak apex spectrum and the spectrum from the library with the lowest Hit Quality 273 Iris HPLC Spectral Processing Software To visually compare how close the apex spectrum of the currently selected peak matches to additional library spectra 1 Check Sample on the Hits List The peak apex spectrum from the currently selected peak is displayed 2 Check any number of library spectra on the Hits List that you want to compare The selected spectra are displayed in the Results pane To examine the Peak Library Search values at different wavelengths gt Enter a new value for Minimum Wavelength and or Maximum Wavelength The Peak Library Search value labels are updated for every peak in the chromatogram To examine the effect of using baseline corrected spectra on the Peak Library Search values gt Check Baseline Correct Spectra The Peak Library Search value labels are updated for every peak in the chromatogram To add the displayed spectra in the results pane to the Data Tree gt Select Actions gt Add Al
280. tion of your mouse pointer is displayed in the appropriate pane If you see a chromatogram that you want to temporarily extract just double click on that area in the 3D Plot and the chromatogram at the at the point you clicked appears in the Chromatogram pane Note Chromatograms that are captured from a 3D Plot are only temporary and will be cleared when you select a different view How do I close displayed chromatograms gt You can close a chromatogram by selecting the chromatogram from the data tree and then selecting File gt Close When you close a chromatogram the chromatogram is removed from the Data Tree and all of the chromatogram s associated displays such as the chromatogram Contour Map and 3D Plot as well as all of the associated spectra are no longer shown If you attempt to close an extracted chromatogram or calculated spectrum that has not yet been saved a message appears and states The items selected for closing include data that has not been saved Do you want to continue Click the Yes button on the message dialog to save the Data 119 Iris HPLC Spectral Processing Software How do I close all displayed spectra gt 120 You can close all of the spectra that appear on the Data Tree by selecting File gt Close All Spectra When you select this command all spectra from the Data Tree are removed If the Data Tree displays calculated spectra that have not yet been saved a message appears th
281. tion this pane appears blank To add a spectrum to this pane you must first click on an area inside the whitespace of the pane and then click on a spectrum listed on the Data Tree The selected spectrum now appears on this pane Views guro 2 Gantiied but with cosition 7 341 Spectrum B 191 Iris HPLC Spectral Processing Software e Display List You use the Display List to select the information you want displayed on the Results Pane When items appear checked on this list they are displayed in the Results Pane Meanwhile unchecked items are not displayed En Al 103 192 Chapter 7 Performing Operations on Spectra Parameters Pane The Parameters Pane displays the wavelength range for the calculation whether or not baseline corrected spectra are used for the spectral math as well as the Threshold controls which you can manually set to a value above the system noise You can modify these parameters and IRIS automatically updates the Results pane Note The result of dividing two noisy small numbers can be very unstable therefore you can use the Threshold controls to set the minimum absorbance values above the system noise and therefore obtain a more reproducible result Na EER 193 Iris HPLC Spectral Processing Software More specifically the Parameters Pane allows you to specify the following parameters Minimum Wavelength Sets the lower limit of the spectrum range to be included in a
282. to View command from the context menu will add the Spectrum to the Data Tree or drag drop of the label can be used CE Ce EE 137 Iris HPLC Spectral Processing Software How do I adjust the pane width and height You can adjust the height and widths of any of these panes to make them smaller or larger To adjust panes 1 Place the pointer over the edge of the pane that you want to adjust The pointer turns into a line with arrows on each end vue 2 Press the left mouse button and drag up down left or right The pane is resized after you release the mouse button The program maintains these settings until you adjust the panes again 138 Chapter 5 Viewing the Data How do I view chromatograms and spectra on the Spectra 3D View In this section you will learn how to capture and display spectra and chromatograms from the 3D Plot on the Spectra 3D View Note A captured spectrum is a spectrum extracted from its source and displayed permanently in the Spectra pane and is listed on the Data Tree A captured spectrum can be hidden and or removed To extract and display a chromatogram and spectrum from a point on the 3D Plot 1 From the Views Tree select Spectra 3D View The 3D Spectra View displays 2 From the Data Tree click on the chromatogram you want displayed as a 3D plot 3 Float your mouse pointer over a point on the 3D plot to temporarily view in their respective panes the chromatogram and spe
283. to be included in the calculation The absorbance threshold value will eliminate certain data points from the calculation of the result If too many data points are eliminated the result becomes questionable Therefore the Minimum Data Points parameter is used to set the minimum number of data points that must be present for a valid result The default value is twenty If the number of data points falls below this number the result is reported as 0 and the test is considered as a fail Check this box use baseline corrected spectra in the calculation This parameter allows you to set the maximum value at which the two spectra are considered to match If the two spectra match exactly then the value will be 1 To allow for noise and other errors in the system this value is normally set at 1 5 You can reduce or increase this value to fit your own criteria Values that exceed this number are labeled in red on the Results pane 209 Iris HPLC Spectral Processing Software Parameter Use at of Peak Height Absorbance Threshold 210 Description This parameter allows you to change the position from where the upslope and downslope spectra are extracted The position is defined as a percentage of the chromatographic peak height the lower the percentage the closer to the baseline are the spectra taken This parameter is useful if you are looking for possible impurities When you specify a lower percentage value and thereb
284. trum As dialog appears On the Save Spectrum dialog you specify a file name and location for the spectrum How do view a previously stored individual spectrum 1 Once a spectrum is saved using the procedure described above you can view the spectrum again by selecting File gt Open gt Spectrum The Open Spectrum dialog appears 2 Select the spectrum you want to open and click Open The selected spectrum is opened and now appears as its own node on the Data Tree On the Main View and Chrom Spectra View and Compare View you can display this spectrum by checking it on the Data Tree The spectrum is displayed on the Spectra pane 85 Iris HPLC Spectral Processing Software Removing Spectra and Hiding Spectra from the Data Tree Removing Spectra from the Data Tree gt Ifyou want to remove all of the spectra from the Data Tree select File gt Close All Spectra All of the spectra are removed from the Data Tree gt Ifyou want to remove a spectrum from the Data Tree right mouse click on the spectrum you want to remove and select Close from the context menu that appears Hiding Spectra from Being Displayed gt Ifyou do not want to display a spectrum on the Main View or Chrom Spectra View you can hide it by unchecking the spectrum on the Data Tree 86 Chapter 4 Viewing Spectra Obtaining Information on a Stored Spectrum There are two ways you can obtain information about a spectrum You can use the Informatio
285. turned off Electronic signature for a result file is automatically enabled if any of the methods used to create it have electronic signature enabled IRIS records the following information about electronic signatures in the audit trails e When electronic signature is enabled for a file an entry is made in the audit trail to record the fact that signature requirement has been started e When a user enters the correct password for a file that has electronic signature enabled the audit trail entry for the transaction will show that the electronic signature was verified 53 Chapter 3 Opening and Viewing Chromatograms Chapter 3 Opening and Viewing Chromatograms Introduction Now that you have a general understanding of the IRIS user interface this section will introduce you to the most basic element in IRIS the chromatogram IRIS was designed answer the question What chromatographic information can get from the spectra associated with this chromatogram or perhaps more clearly What information about the peaks in this chromatogram and the components in the sample can get from the spectra associated with this chromatogram It s not surprising then that most of the tasks you will perform in IRIS begin with chromatograms This chapter shows you how to open a chromatogram to begin your investigation You will also learn how to obtain information about a chromatogram before you open it 55 Iris HPLC Spectr
286. ult Method select Tools gt Edit Default Method from the IRIS menu bar Tell me about the Edit Method dialog The Edit Method dialog is comprised three main areas e A list box that lists the components of the spectral method file Click on one of the items listed here and the right hand portion of the dialog displays the parameters for the selected item Method Editor Default tsm General Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram Printing Last Edited Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram 4 9 2006 2 39 43 PM Description Audit Trail You can modify any of the displayed parameter values and select Save to update the default method Iris HPLC Spectral Processing Software e The Parameters display shows the parameters and their values for the operation you have selected Method Editor Default tsm General Library Match Minimum Wavelength Spectral Math E Peak Purity 190 Absorbance Ratio Wavelength Maximum Maximum Wavelength Spectral Standard Con
287. ults Pane This pane displays a graphical representation of the items that are checked on the Display List In addition when a peak is selected on the chromatogram the Results pane displays the Absorbance Ratio for the selected peak The Absorbance Ratio is labelled as Ratio A B Ratio A B 0 35 Note Whenever you select a different peak change the parameters for the operation or select deselect an item on the Display List the Result pane is automatically updated to reflect the change 221 Iris HPLC Spectral Processing Software How do modify the parameters that are used to determine the Absorbance Ratio values The Parameters pane displays the values that are currently used in the operation At any time you can optimize adjust the parameters that are listed on the Absorbance Ratio operation and IRIS automatically updates the display with the new results Below is a list of the parameters you can modify Wavelength A These spin boxes show the two wavelengths used for the ratio and which you can modify The ratio is always calculated A B Wavelength B Wavelength A may be less than equal to or greater than Wavelength B Baseline correct spectra Check this option to use the baseline corrected spectra in the calculation Absorbance Threshold To ensure that IRIS calculates the Absorbance Ratios for small peaks but does not interpret baseline noise as peaks you can use this parameter to set the min
288. um Y value in the active window i e the Chromatogram or Spectra pane that is currently selected to 90 for each spectrum or chromatogram and sets the X axis scale so that all of the largest spectrum or chromatogram is displayed All chromatograms or spectra in the selected pane are affected by this command Figure 4 5 below shows a range of spectra displayed over the last peak Because the spectra in the display below are of varying sizes it is not clear if the chromatographic peak is homogeneous nor is it clear whether or not all the spectra are identical or if the spectra vary across the peak To better compare the peaks you can use the Normalize commands since these commands will convert all of the peaks to the same maximum height Eile Edit View Actions Tools Help elelalelalel2lnial lwl felesie wl elelose o Ereren Chrom Spectra View Spectra Main View Chrom Spectra Contour Map Spectra3D Compare Operations Custom Views 02 838 02 845 2 853 H286 2 867 M 2 575 2 897 E 2 904 M2911 M2 919 2 926 m Login manager a 4 Figure 4 5 Range Spectra display over the last peak 92 Chapter 4 Viewing Spectra If the Normalize X and Y command is applied to Figure 4 5 it is evident that all the spectra do appear to be identical and therefore the chromatographic peak is homogeneous Tor Main View Chrom Spectra Contour Map Spectra3D Compare Operations Cu
289. um of each named peak in the sample to an identically named spectrum from a spectral library that you specify gt To access this operation expand the Operations node on the Views tree and select Spectral Library Confirmation File Edit View Actions Tools Help 3 lalale Mlals welaj mE o Past uel waa ws Tesi e lun Spectral Library Confirmation Sample Spectral Library Confirmation Operations Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confir Spectral Library Confirme Peak Library Search f Retention Time Adjustme Extract Chromatograms w a Minimum Wavelength 230 Maximum Wavelength aoo Hit Distance Threshold joon ea PropyiBenzene 0 Anthracene 0 P ButyiBenzene 0 P IV Baseline Corect Spectra PRLS ED CD ELE 44 22 33 44 65 6 6 77 88 r Library List example1_well_separated001 0 PropylBenzene C Program Files PerkinE Imer Instruments Iris apex alb I Display Apex O Spectrum Baseline Library O Library Baseline PEE SELER SEUN ea VLE STS PR ong TE R Ro EOE A E rg RUST A Lt Ett OU et TA 220 275 330 385 Login manager Figure 8 5 The Spectral Library Confirmation operation 250 Chapter 8 Performing Operations on Chromatograms Verifying the Identity of Chromatographic Peaks by Comparing to a Spectral Library To perform this oper
290. v a apa 14 22 33 44 55 66 77 88 ots TELETELE EETEIEETEEEEETELLEEIEEEETTEN 385 Login manager amp Figure 1 1 The Main View is displayed when the I RIS application is started Iris HPLC Spectral Processing Software The Views Tree The Views Tree appears in the upper left hand pane of the IRIS window and is your means of navigating though IRIS From the Views Tree you select what you want displayed in the right hand portion of the screen Main View Chrom Spectra Contour Map Spectra3D Compare Operations Library Match Spectral Derivative Spectral Math Peak Purity Absorbance Ratio Wavelength Maximum Spectral Standard Confirmation Spectral Library Confirmation Peak Library Search Retention Time Adjustment Extract Chromatograms Apex Optimized Chromatogram amp Custom Views Figure 1 2 The Views Tree When you select an item on the Views Tree the right hand portion of the IRIS window displays the selected view If you select a header item such as Operations or Custom View the right hand side of the window displays empty panes Chapter 1 Introduction Tell me about the Views and Operations that are listed on the Views Tree In IRIS you work with Views and Operations Basically Views allow you to view chromatograms and spectra on the right hand side of the IRIS window Meanwhile Operations which are also displayed on the right hand side of the IRIS wi
291. value in the top right corner of the pane and optionally its baseline spectrum To view the Absorbance Ratio for a different peak gt Select the required peak by clicking on it in the chromatogram The Results pane is updated to show the peak apex spectrum the Absorbance Ratio value and the baseline spectrum for the selected peak To examine the Absorbance Ratios at different wavelengths gt Enter a new value for Wavelength A or Wavelength B The Absorbance Ratio value labels are updated for every peak in the chromatogram To examine the effect of using baseline corrected spectra on the Absorbance Ratio values gt Check Baseline Correct Spectra The Absorbance Ratio value labels are updated for every peak in the chromatogram To change the minimum absorbance value that is used in the calculation of the Absorbance Ratios 1 Select the Manual radio button The Minimum Absorbance spin box is enabled 2 Use the spin box to specify a new minimum absorbance value The Absorbance Ratio value labels are updated for every peak in the chromatogram 223 Iris HPLC Spectral Processing Software To return to automatically calculating the minimum absorbance value gt Select the Auto radio button if you wish to have IRIS automatically calculate the minimum absorbance value that can be used in the calculation The Absorbance Ratio value labels are updated for every peak in the chromatogram To add the displayed spectra in t
292. ved the spectrum it can be reopened by selecting File gt Open gt Spectrum from the IRIS menu bar To save a spectrum that you have extracted from a chromatogram 1 From the Data Tree click on the spectrum you wish to save 2 From the menu bar select File gt Save As The Save Spectrum As dialog appears 3 From the Save As dialog enter a File name for the UV file and click Save The spectrum is saved and a information header is added to the UV file that identifies the source of the chromatogram the user s full name user id and the date and time the spectrum was saved 102 Chapter 4 Viewing Spectra Defining How You are Going to Perform the Baseline Correction of the Spectra The Spectral Baseline Correction dialog allows you to define how you are going to perform the baseline correction of the spectra Baseline correction is achieved by subtracting the appropriate absorbance baseline spectrum from the absorbance spectrum Spectral Baseline Correction 05 1 18 2 25 3 38 4 4417 5 55 6 85 7 75 8 85 9 Peak Start Only C Selected spectrum Average of range Figure 4 13 The Spectral Baseline Correction dialog allows you to define how you are going to perform the baseline correction of the spectra 103 Iris HPLC Spectral Processing Software On the Spectral Baseline Correction dialog you can select from the following three options that are available to you for calculating selecting the baseline sp
293. view and click Open The Edit Library dialog appears Edit Library Library Details Name example library alb Description me Minimum Wavelength Maximum Wavelength 235 400 Spectra Current Spectra Library Toluene Ethyl Benzene Propyl Benzene Butyl Benzene Anthracene 0 275 330 385 M Show baseline corrected spectrum I Show baseline spectrum Audit Trail 165 Iris HPLC Spectral Processing Software How do I add extracted spectra into a library 1 From the Edit Library dialog select the spectrum you wish to add from the Current Spectra list box 2 Click the Add button The Add to Library dialog box appears and prompts you to enter a Component Name Add to library Component Name o OK Cancel 3 Enter the name of the component carefully Note Make sure that you enter the component name correctly before you click OK The component name cannot be edited once it has been entered into the library 4 Click OK The dialog closes and you are returned to the Edit Library dialog from where the newly added spectrum is displayed in the Library list How do I exclude a spectrum in the Library List Note The exclude command permanently excludes a selected spectrum you cannot undo this action To permanently exclude a library spectrum 1 Select the spectrum you wish to exclude from the Library list box The Exclude button is enabled 2 Click Exclude A dialog
294. wisfalsia wewee o so thst wel wz neler Aa h fawj Library Match Sample i Litvay Motch Spectres Compare Migimum Wavelength EO 70 5 Library Match A Spectral Derivative Spectral Math Maoarnum Wavelength Poak Purty 400 a Absorbance Ratio nd Wavelength Maamum I Match Retention Time Window Spectral Standard Confirmatior e Senrt likens Conformation Y KF 5 lt I Batetne Conected Date examete 3 Kenttied butyl benzene Doray List a I Hits Ce ee ee ee et eet 4 i gt 220 2 170 Chapter 6 Spectral Libraries Parameters Pane This pane is where you set and investigate the various parameters including the list of libraries that will be searched that control the matching process Whenever you change a parameter displayed on this operation and have a spectrum selected on the Data Tree Iris automatically re runs a search and updates the Hits List and Hits Pane Match Sample Spectrum omer 6 Butyl Henzene 171 Iris HPLC Spectral Processing Software Hits List The Hits List contains a list of the spectra from the library s that best match the sample spectrum in hit order These matching spectra are listed by their hit quality and name The hit quality is displayed as a numeric value a hit quality of 0 indicates a perfect match The spectra that appear checked on this list are displayed in the Hits Pane Therefore it should als
295. with a chromatogram without capturing the spectra permanently in the Spectra pane If you do not want permanently capture a spectrum from a chromatogram simply float your mouse pointer over the chromatogram 3D plot or contour map and the spectrum from that point is temporarily displayed on the Spectra pane of the current View Note To preview spectra associated with a particular chromatogram as well as extract spectra from a chromatogram the pane you are extracting from must be set to a Stacked display and the Spectra pane must be set to an Overlaid display File Edit Yiew Actions Tools Help 2 5 ie fea eafen OFF fe ad swe ur wala A a g Z Main View Chrom Spectra Contour Map i A Spectra3D U kie A Compare Operations Custom Views CTO UY LO OO LT ED LT LO aje 0 511 622 533 644 55 566 677 588 59 example 1 identified and 04 example 2 identified but with coe 0 075 0 05 0 025 0 LALE UU EILEEN ERIEN Cc LIREN EELEE TEELT 200 225 250 275 300 325 350 375 400 Login manager amp Figure 4 1 On a stacked chromatogram display you can hover your mouse over the chromatogram and the spectrum from that point on the chromatogram is displayed in the Spectra pane 78 Chapter 4 Viewing Spectra How do I work with the Spectra pane To work with the Spectra pane you must first select the pane by clicking on the white space of the pane The pane
296. y Sor Q os sausnaguaaresaeespUamenspra astm AAMEN AEELASAPO RARA 4 he 33 as ss ao 77 es Reteriion Tine Adantive Mrym Woveiengh 1230 zj Mamnun Anshai l4 Extract Crornstog ae Custom Views wa r atrreshedPedk UMeence Wavelengh A 400 lt y n py gt Data mrampie 4 kiertfied buty de Reference Bardan f W Baine carect pecia Apes Optenieed Cironat f Apex Optimized Alnebarce Theechott Afo E Apes 302 Chapter 8 Performing Operations on Chromatograms Apex Optimized Chromatogram Pane As soon as you select the sample chromatogram from the Data Tree IRIS calculates the optimum wavelength for each peak and extracts the chromatogram at these different wavelengths and displays the Apex Optimized Chromatogram in this pane The first peak on the apex optimized chromatogram is automatically selected and appears highlighted in pale green The apex spectrum for the selected peak is shown in the bottom Spectra pane To select a different peak simply click on that peak 303 Iris HPLC Spectral Processing Software e Parameters Pane This pane is where you set and investigate the various parameters used to calculate the Apex Optimized Chromatogram Whenever you change a parameter displayed on this operation and have a chromatogram selected on the Data Tree IRIS automatically updates the display with the new Apex Optimized Chromatogram Apex Optimized 304
297. y a range of 190 400 for UV only data or specify 400 700 for visible only data or 190 700 for UV and visible data Chapter 6 Spectral Libraries Click OK to close the Create Library dialog The Audit Trail dialog appears Depending upon how your TotalChrom Administrator has configured audit trailing you may be required to enter a Comment about the library you are creating on the Audit Trail dialog In addition if your TotalChrom Administrator has created a Reasons list in TotalChrom you may also be required to specify a Reason on the Audit Trail dialog Click OK when you have finished entering the required information on the Audit Trail dialog The Electronic Signature dialog appears From the Electronic Signature dialog enter your User Name and Password and click OK The Electronic Signature dialog closes and the Edit Library dialog appears At this point the new library has been created although it contains no spectra Spectra may be added to the library at any time For more information on adding spectra see How do add extracted spectra into a library on page 166 Edit Library Library Details Name example3 alb Description Minimum Wavelength Maximum Wavelength 190 400 Spectra Current Spectra Library V Show baseline corrected spectrum Show baseline spectrum Audit Trail 159 Iris HPLC Spectral Processing Software Viewing a Library The View Library
298. y limits for a 3D plot and reverse the Wavelength AX S 0 ceececeeseeeee eee e eae ene terre eeeeaeaaaaaeeereeeeeeaeaa 141 Table Of Contents How do reverse the wavelength axis of a 3 D Plot ceee 142 How do use the Autoscale commands to scale a 3D Plot 143 COMPare VIGW merie ade carte lect E e ea E TAA ok deat cusp edemee tech 144 Tell me about the Compare VIEW 144 How do adjust the pane width and height ceecee 149 CUSTOM Views aah tcccnaficknsces GS ate rete alvavsea ac bacre ates ae bee as becsladecnentawuactonns 150 Chapter 6 Spectral Libraries sssssssssnns 1115 5 151 About Spectral Libraries ccc cee cceeee eee e ae neneeee tesa seas snaaaeeeeeeeeeeaeaaaaies 152 Automatically Creating a Library from Named Peaks n se 153 How do create a spectral library using the apex spectra from named peaks in a chromatogram sceseeeeee 154 Manually Creating a Library cece eerie eeeeeee rene eat eeeeenees 157 How do create a new library 158 Viewing a Librai aana ia a aaa e a a aa 160 How do I access the View Library dialog ceeeeeeeeeeeeeeeeeeeeeees 160 Tell me about the View Library dialog ceee 161 Editing a Library cscs sez vege aa a eat A AEA ARAE ATE 162 Tell me about the Edit Library Dialog cecce 162 How do I access the Edit Library dialog escenccceecee 165 How do add extracted spectra into a library cecce 166 How do I exclu
299. y move further out on the peak i e closer to the baseline you will notice that spectral differences are increased However it should be noted that by setting a lower percentage value for this parameter the signal to noise will decrease thereby increasing the risk of false positives The result of dividing two noisy small numbers can be very unstable therefore you can use the Threshold controls to set the minimum absorbance values above the system noise and therefore obtain a more reproducible result When Auto is selected the absorbance threshold values are calculated automatically by the system and are set to either 0 0005 A U or 2 of the maximum absorbance in the spectrum whichever is greater The entry field is grayed when Auto is selected When Manual is selected enter the required value in the entry field by either typing directly or using the spin buttons When Manual is first selected the minimum absorbance value calculated by the Auto function is displayed in the Manual threshold field Chapter 8 Performing Operations on Chromatograms Summary of Operation Peak Purity The summary below illustrates how to calculate the purity of peaks in a chromatogram and then save the new results and parameters used in the calculation To review and recalculate Peak Purity values for the peaks ina chromatogram 1 From the Views tree expand the Operations node and click on Peak Purity The Peak Purity Operation displays
300. y the sample spectrum gt You can access the Library Match operation by selecting Operations gt Library Match from the Views tree Note Prior to accessing the Library Match operation the spectrum you wish to identify must already be extracted and displayed on the Data Tree Tell me about the Library Match operation The Library Match operation is comprised of the following areas e Views Tree From the Views tree you select Operations gt Library Match to access the Library Match operation Spectral Standard Contirmatior Snactralliteary Confirmation Y gt 168 Chapter 6 Spectral Libraries Data Tree The Data Tree displays a list of extracted spectra that are grouped by their parent chromatogram From the Data Tree you select the spectrum you wish to identify When you click on a spectrum listed in this tree a graphical representation of the spectrum appears in the Spectrum Pane The spectrum selected on the Data Tree is highlighted in blue Hits Sample Spectrum x gt oooosGg Note Whenever you select a spectrum from the Data Tree the software automatically runs a search using the parameters specified on this operation and updates the Hits List and Hits Pane 169 Iris HPLC Spectral Processing Software e Spectrum Pane This pane displays the spectrum that you selected from the Data Tree lt lt Iris G BR Fie Edt View Actions Took Help eisiaieiaialaimalas
301. ys a standard file selector enabling a custom view exported to disk to be imported into this view tree Enabled at all times Sets the control over the zoom slider All three are independent toggles enabling any combination to be switched on at the same time to create a multi directional zoom X and Y are enabled when a 2D graph is selected all three when a 3D plot is selected Rescales the selected graph to the maximum range of the data displayed in either just the Y direction or both depending on the command selected Enabled when a 2D graph is selected and the full range is not currently shown 19 Iris HPLC Spectral Processing Software Menu 20 Command Normalize gt X and Y Y only Offset Point Zero Previous scale 3D graph tools gt yX only vY only Label Chromatograms Annotations gt Add Edit Delete Delete All Description Rescales the selected graph in line with the command selected X and Y and Y only will operate based on the full graph Offset will normalize to the maximum point to the right of the X axis cursor Point on a spectrum or chromatogram will normalize at the current X axis cursor position while on a contour map this command will assign all absorbance values above the current X axis cursor position to the top contour This command only applies to contour maps When a Contour Map pane is selected this command assigns all absorbance values below the X axis curs
Download Pdf Manuals
Related Search
Related Contents
AP プラスチック リペアキット 取扱説明書 HyPerformance Plasma HPR130 Auto Gas Manual de Instrucciones CMT-RB5 VERLINDE EUROSTYLE ES - JPG Robertshaw 8601 User's Manual PQLabs Touch Screen Platform Linearantriebe ALS 25.1 - ALS 75.1 mit Fail-Safe Funktion Manual técnico Rapport final () - Département Informatique Copyright © All rights reserved.