Home

Loop-IP6416 IP-IMUX

image

Contents

1. Model ROHS compliant Main Unit Loop IP6416 S 1UA 4FE s1 s2 s3 s4 pp1 1U height ANSI unit front and rear access pp2 add2 add3 G Description Note Where s1 s2 s3 s4 pp1 pp2 add1 stand alone with 4 Fast Ethernet FE ports add2 and add3 are defined in tables Loop IP6416 S 1UA 3FE s1 s2 s3 s4 pp1 1U height ANSI unit front and rear access below pp2 add1 add2 add3 G stand alone with 3 Fast Ethernet FE ports and daughter board The add 1 is not applicable for 4 FE Loop IP6416 S 1UE 4FE s1 s2 s3 s4 pp1 1U height ETSI unit front access stand alone pp2 add2 G Loop IP6416 S 1UE 3FE s1 s2 s3 s4 pp1 1U height ETSI unit front access stand alone pp2 add1 add2 G Hot swappable Plug in modules Loop 1P6416 S ETD G Loop 1P6416 S EM G Loop 1P6416 S ETR G Plug in Power Modules Loop IP6416 S SA G Loop IP6416 S SD48 G Accessories Power Cord Loop ACC PC USA Loop ACC PC EU Loop ACC PC UK Loop ACC PC AUS Loop ACC PC CH Conversion Cable Loop ACC CAB DB25M 100 8BNCM Loop ACC CAB DB25M 100 4RJ48M Loop ACC CAB BNCM 100 MAXM Loop ACC CAB DB25M 30 1DB37F Loop ACC CAB DB25M 30 1M34F Loop ACC CAB DB25M 200 1M34F Loop ACC CAB DB25M 30 1DB15F User s Manual Loop 1P6416 UM with 4 Fast Ethernet FE ports For allowed pp1 pp2 combinations refer to NOTE 1 with 3 Fast Ethernet FE ports and daughter board Future option for 3FE Quad E1 T1 with DB25 female connector E1 120 ohms E1 75 ohms T1 softwar
2. e Console port VT100 menu driven SNMP port SNMPvi Telnet via SNMP port LoopView GUI EMS Inband management in traffic bandwidth RoHS Compliant Future option Loop IP6416 IP IMUX Description The Loop IP6416 IP Inverse Mux is a media converter It allows service providers to offer Ethernet services over the existing copper optical or microwave infrastructure carrying the E1 T1 network Up to 16 E1 T1 lines can be enabled and concatenated to form a single channel Ethernet frames are mapped into this single concatenated channel The Loop 1P6416 offers up to 16 E1 T1 ports with an LED for each port It has automatic E1 T1 channel failure detection and can reassign the number of E1 T1 channels transporting Ethernet traffic For example if there are 16 E1s configured for 10 100 Ethernet traffic transport and one E1 fails during service the other 15 will pick up the entire load This minimizes the loss of IP packets Several power options exist including dual DC front back AC and hybrid AC DC The Loop IP6416 supports a console port which allows users to execute in service diagnostics and fault isolation from a local or remote terminal The Loop 1P6416 also allows remote site connection to Telnet via the Ethernet port An Alarm Cut Off ACO button is located on the panel Ordering Information To order specify Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code
3. 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 86 22 8789 0344 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version 6 8 JAN 2009 Subject to change without notice
4. 90 Km PTCVW Dual uni directional fiber 1550 LC without DDM 110 Km PTCXW Dual uni directional fiber 1550 LC without DDM 120 Km PTB1D Dual uni directional fiber 1310 LC with DDM 10 Km PTB3D Dual uni directional fiber 1310 LC with DDM 30 Km PTB4D Dual uni directional fiber 1310 LC with DDM 40 Km PTC5D Dual uni directional fiber 1550 LC with DDM 50 Km PTC6D Dual uni directional fiber 1550 LC with DDM 60 Km PTC8D Dual uni directional fiber 1550 LC with DDM 80 Km PTC9D Dual uni directional fiber 1550 LC with DDM 90 Km PTCVD Dual uni directional fiber 1550 LC with DDM 110 Km PTCXD Dual uni directional fiber 1550 LC with DDM 120 Km PKB1W Dual uni directional fiber 1310 LC without DDM 10 Km NOTE 1 2 WHD2S Master is used with WHE2S Slave For other special optical modules please contact your nearest Loop sales representative Power dB 19 30 19 17 34 19 19 Distance 2 km 15 20 km 30 km 50 km 80 km 100 km 120 km 30 km 50 km 80 km 100 km 120 km Power dBm 8 5 8 5 10 10 20 19 20 22 24 27 30 23 15 20 19 20 22 24 27 30 23 15 WAN E1 Interface Line Rate Line Code Framing Output Signal Input Signal Connector Jitter WAN T1 Interface Line Rate Line Code Framing Output Signal Input Signal Connector Pulse Template Surge Protection Encapsulation Protocol 2 048M bps 50 ppm AMI HDB3 ITU G 704 ITU G 703 ITU G 703 RJ48C 120 ohm DB25 120 ohm with optional conver
5. For ANSI unit DC power is available in rear panel only For ETSI unit all power modules in front pp1 P9 Fixed AC and DC coexistent power pp1 SA Single AC power plug in pp1 SD48 Single DC power plug in pp1 SD48 pp2 SD48 Dual hot swappable DC power plug in E Where add1 must be used to select one daughter card If add1 is not required leave this field blank DTE daughter card Future option Optical Fast Ethernet daughter card Optical Fast Ethernet with SFP housing daughter card Combo GbE daughter card Future option add1 DTE NHB3S NHB5S NHB3F NHC2S NHCUS WHD2S WHE2S SFPC SFPGC Description 1 DTE V 36 DB25 female connector and 1 RS232 DB9 female connector daughter card DTE optional interfaces can be either V 36 RS449 V 35 EIA530 or X 21 V 36 RS449 via DB25 male to DB37 female conversion cable V 35 compatible DB25 female connector V 35 compatible via DB25 male to M34 female conversion cable EIA530 DB25 female connector X 21 via DB25 male to DB15 female conversion cable Single mode 1 9 1310 nm commercial 0 to 70 C 30 km SC duplex optical connector Single mode 1 9 1310 nm commercial 0 to 70 C 50 km SC duplex optical connector Single mode 1 9 1310 nm commercial 0 to 70 C 30 km FC duplex optical connector Single mode 1 9 1550 nm commercial 0 to 70 C 15 to 20 km SC duplex optical connector Single mode 1 9 1550 nm c
6. mode optical module with dual uni directional fiber 155M 1550nm 120Km LC connector w o DDM L 1 2 extended distance Single mode optical module with dual uni directional fiber 155M 1310nm 30Km LC connector with DDM S 1 1 IR1 Fast Ethernet Single mode optical module with dual uni directional fiber 155M 1310nm 50Km LC connector with DDM L 1 1 LR1 Fast Ethernet Single mode optical module with dual uni directional fiber 155M 1550nm 80Km LC connector with DDM L 1 2 LR2 Single mode optical module with dual uni directional fiber 155M 1550nm 100Km LC connector with DDM L 1 2 LR2 Fast Ethernet Single mode optical module with dual uni directional fiber 155M 1550nm 120Km LC connector with DDM L 1 2 extended distance Note Select one daughter card only Conversion cable is not included Order conversion cable separately from Accessories listed in ordering information Select one daughter card only See Product Specifications below for optical connector information Use WHD2S with WHE2S Use WHE2S with WHD2S Order SFP optical modules separately from SFP FE table below Order SFP optical modules separately from SFP GbE table below Use 2 fibers for all SFP optical modules SFP Optical Module for Gigabit Ethernet GbE 1 25G mini GBIC Dual Fiber Commercial 0 to 70 C MTAFW MTAFD MTBTD MTBTW PTB3W PTB4W PTC5W PTC6W PTC8W PTC9W
7. to 240 Vac and 48 Vdc 36 to 75 Vdc fixed on panel lt 30 watts 438 mm x 44 mm x 228 mm WxHxD 0 50 C 0 95 RH non condensing Desk top stackable wall mount EN55022 Class A EN55024 FCC Part 15 Class A EN60950 1 IEC60950 1 Standards Compliance ITU T ATIS ANSI IEEE IETF G 703 G 704 G 705 G 775 G 806 G 823 G 7041 Y 1303 G 7042 Y 1305 G 7043 Y 1343 G 8021 Y 1341 G 8040 Y 1340 T1 107 802 3 802 10 802 ad RFC1661 ANSI Unit Front Panel Views AC Power Plug in Module ANSI Unit Rear Panel Views and ETSI Unit Front Panel Views kz Quad ETTI sachs connector Plug in Module Quad E1 T1 DB25 connector Plug in Module _ connector Plug in Module Loop Alarm External 4 Hot swappable Plug in Slots oy Relay Clock i O Pa l 4 FE N o Fast Ethernet SNMP amp Console Port Alarm Cut Off ACO Optical Fast Ethernet Fixed oe Card Panel amp 3 FE and 1 Optical FE FC SC connector Optical Fast Ethemet SFP Fixed Daughter Card T a a a ic Ult oie ty di ALT i e a i Panel amp 3FE sn 1 Optical FE SFP housing Combo Gigabit Ethernet Fixed Daughter Card T si __ Ts MR e areas Panel 3FE and 2 Combo GbE 2 RJ45 and 2 SFP connectors 4 a dii CI wo n a ns DTE 36 and RS232 B E ig cirio a i a iBS Gian i lia ae dc morti mm Fixed Daughter Card Panel 3 FE 1 DTE V 36 and 1 RS
8. 232 48 Vde Power Plug in Module AC and DC coexistent Power Fixed Module Note ANSI without logo ETSI with logo ETSI Rear Panel Views Loop 1P6416 Maximum Capacity Reference Table WAN port Tributary Port on Main Board _ Tributary on a Fixed Daughter Card uture option 16 E1 T1 SFE CS DE V 36 and 1 RS232 uture option Application Illustration Point to Point Application Tributary ports WAN ports WAN ports Tributary ports FE FE Optical FE Optical FE Optical FE SFP E1 T1 1 Optical FE SFP Combo GbE Combo GbE DTE V 36 and RS232 DTE V 36 and RS232 E1 T1 16 E1 T1 16 Point to Multipoint Application VCAT disable If all of the packets from four Loop 1P6416 LANs are untagged then one Loop 1P6416 can be connected to a maximum of four Loop IP6610 devices LAN1 LAN2 E1 T1 E1 T1 LAN4 E1 T1 Point to Multipoint Application VCAT disable If all of the packets from four Loop 1P6416 LANs have different VLAN tags then one Loop IP6416 can be connected to a maximum of sixteen Loop IP6610 devices E1 T1 E1 T1 LAN1 E1 T1 LAN2 LANS E1 T1 LANS E1 T1 E1 T1 P K Technologies 4 rue Edouard Branly Immeuble Hermes II 78190 TRAPPES FRANCE Tel 33 134 521 480 Fax 33 134 521 489 www pkt net com LOOP TELECOMMUNICATION INTERNATIONAL INC LoopTelecom com ISO 9001 ISO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No
9. LCD Conversion cable Loop ACC CAB DB25M 30 1M34F Description DB25 pin Male to M34 Female V 35 conversion cable Length 30 cm Examples 4 Main unit Loop IP6416 S 1UE 4FE EM EM SA EXT G Description An ETSI unit with 4 Fast Ethernet FE ports quad E1 75 ohm with mini BNC quad E1 75 ohm with mini BNC 100 to 240 Vac power and external clock Examples 5 Main unit Loop IP6416 S 1UE 3FE ETR ETR ETR ETR SD48 SD48 SFPC Description An ETSI unit with 3 Fast Ethernet FE ports quad E1 T1 with RJ48C connector quad E1 T1 with RJ48C connector quad E1 T1 with RJ48C connector quad E1 T1 with RJ48C connector dual hot swappable 48 Vdc power and SFP mini GBIC housing daughter card without SFP optical module Conversion cable Loop ACC CAB BNCM 100 MAXM Description BNC Male to Mini BNC MAX Male conversion cable Length 100 cm Loop IP6416 IP I MUX Product Specifications Optical Module Characteristics for Fast Ethernet FE Optical Fiber Direction Wavelength Connector Distance Module km NHB3S Singlel mode dual uni directional fiber 1310 SC Subscriber Connector 30 NHB5S Single mode dual uni directional fiber 1310 SC Subscriber Connector 50 NHB3F Single mode dual uni directional fiber 1310 FC Fiber Connector 30 NHC2S Single mode dual uni directional fiber 1550 SC Subscriber Connector 15 20 NHCUS Single mode dual uni directional fiber 1550 SC Subscriber Connector 100 WHD2S WDM mode single bi directional fiber 1310 Tx SC Subscriber Conn
10. M1000Base APD single mode optical module with dual uni directional fiber 1 25G 1310nm 10Km LC connector with DDM 1000Base LX single mode optical module with dual uni directional fiber 1 25G 1310nm 30Km LC connector with DDM 1000Base LHX single mode optical module with dual uni directional fiber 1 25G 1310nm 40Km LC connector with DDM 1000Base LHX single mode optical module with dual uni directional fiber 1 25G 1550nm 50Km LC connector with DDM 1000Base XD single mode optical module with dual uni directional fiber 1 25G 1550nm 60Km LC connector with DDM 1000Base XD single mode optical module with dual uni directional fiber 1 25G 1550nm 80Km LC connector with DDM 1000Base ZX single mode optical module with dual unidirectional fiber 1 25G 1550nm 90Km LC connector with DDM single mode optical module with dual uni directional fiber 1 25G 1550nm 110Km LC connector with DDM 1000Base APD single mode optical module with dual uni directional fiber 1 25G 1550nm 120Km LC connector with DDM DDM1000Base APD single mode optical module with dual uni directional fiber 622M 1 25G 1310nm 10Km LC connector w o DDM 1000Bse LX NOTE For other special optical modules please contact your nearest Loop sales representative Use 2 fibers for all SFP optical modules All 1 25G optical module downgrading to 622M data rate will be workable E Where ada2 is used to select an external clock If an external clock is not
11. PTCVW PTCXW PTB1D PTB3D PTB4D PTC5D PTC6D PTC8D PTC9D PTCVD PTCXD PKB1W multi mode optical module with dual uni directional fiber 1 25G 850nm 550m LC connector w o DDM 1000Base SX multi mode optical module with dual uni directional fiber 1 25G 850nm 550m LC connector with DDM 1000Base SX multi mode optical module with dual uni directional fiber 1 25G 1310nm 2Km LC connector with DDM 1000Base SX multi mode optical module with dual uni directional fiber 1 25G 1310nm 2Km LC connector w o DDM 1000Base SX single mode optical module with dual uni directional fiber 1 25G 1310nm 30Km LC connector w o DDM 1000Base LHX single mode optical module with dual uni directional fiber 1 25G 1310nm 40Km LC connector w o DDM 1000Base LHX single mode optical module with dual uni directional fiber 1 25G 1550nm 50Km LC connector w o DDM 1000Base XD single mode optical module with dual uni directional fiber 1 25G 1550nm 60Km LC connector w o DDM 1000Base XD single mode optical module with dual uni directional fiber 1 25G 1550nm 80Km LC connector w o DDM 1000 Base ZX single mode optical module with dual uni directional fiber 1 25G 1550nm 90Km LC connector w o DDM 1000Base ZY single mode optical module with dual uni directional fiber 1 25G 1550nm 110Km LC connector w o DDM 1000Base APD single mode optical module with dual uni directional fiber 1 25G 1550nm 120Km LC connector w o DD
12. bps Asynchronous DB9S E1 T1 DTE internal external BNC External BNC is manufacture option The type can be any one of a 2 048M bps E1 120 b 2 048M bps E1 75 and c 1 544M bps T1 which are software selectable E1 T1 DTE internal external manufacture option Alarm Relay Alarm Relay Management LEDs ACO LCD Console Port Inband Management Diagnostics Test Loopbacks Bert Performance Monitor E1 T1 Performance Performance Store Performance Reports Monitor Registers Alarm History Alarm Queue Alarm Threshold Power AC Module 48 Vdc Module AC and DC Module Power Consumption Physical Dimensions Temperature Humidity Mounting Certification EMC Safety Fuse alarm and performance alarm Multi color LEDs A button of alarm cut off 2 line by 16 character LCD with keypad Electrical RS232 DCE Protocol Menu driven VT 100 Connector DB9S female Access via SNMP Ethernet port SNMP v1 Inband management in traffic bandwidth E1 T1 Line Loopback Off QRSS PRBS 2 1 1 1 2 23 1 Last 24 hours performance in 15 minute intervals and last 7 days in 24 hour summary line user Date amp Time Errored Second Unavailable Second Bursty Errored Second Severe Errored Second count User Line Alarm Type i e Master Clock Loss RAI AIS LOS BPV ES UAS Maximum 100 alarm records which record the latest alarm type location and date amp time BPV ES UAS 100 to 240 Vac 36 to 75 Vdc 100
13. d to select the 1 power module pp1 Description P9 Hybrid 100 to 240 Vac and 48 Vdc 36 to 75 Vdc coexist fixed power supply SA Single AC power plug in module 100 to 240 Vac SD48 Single 48 Vdc power plug in module 36 to 75 Vdc Note P9 is a fixed power supply If you order P9 then you cannot select any items for pp2 All plug in power modules are interchangeable For AC choose an appropriate power cord NOTE 1 E Where pp2 is used to select the De power module If pp2 is not required leave this field blank pp2 Description SA Single AC power plug in module 100 to 240 Vac for ANSI only SD48 Single 48 Vdc power plug in module 36 to 75 Vdc NOTE 1 The combinations of ppi and pp2 power modules For ANSI unit pp1 P9 Fixed AC and DC coexistent power at rear pp1 SA Single AC power plug in in front or at rear pp1 SD48 Single DC power plug in at rear pp1 SD48 pp2 SD48 Dual hot swappable DC both rear plug in Note If you ordered the P9 fixed power supply in pp1 above then you cannot select any items for pp2 and must leave the pp2 order field blank For redundancy purposes ordering a second plug in module will provide dual power You cannot order a second SA for ETSI unit For AC choose an appropriate power cord NOTE 1 pp1 SA pp2 SA Dual hot swappable AC one front and one rear plug in pp1 SA pp2 SD48 Hot swappable AC front and DC rear plug in Note
14. e selectable Quad E1 75 ohm with mini BNC Quad E1 T1 with RJ48C connector E1 120 ohms T1 software selectable Conversion cable is not included Single AC power plug in module 100 to 240 Vac Single 48 Vdc power plug in module 36 to 75 Vdc For power redundancy order a second power module For AC choose an appropriate power cord AC power cord for Taiwan America LI AC power cord for Europe AC power cord for UK AC power cord for Australia I AC power cord for China i DB25 Male to eight BNC Male extension cable Length 100 cm DB25 Male to four RJ48C Plugs extension cable Length 100 cm BNC Male to Mini BNC MAX Male conversion cable Length 100 cm DB25 Male to DB37 Female RS449 conversion cable Length 30 cm DB25 Male to M34 Female V 35 conversion cable Length 30 cm DB25 Male to M34 Female V 35 conversion cable Length 200 cm DB25 Male to DB15 Female X 21 conversion cable Length 30 cm This is an optional paper copy A CD version of the manual is already included as standard equipment E Where s1 s2 s3 and s4 are used to select hot swappable plug in E1 T1 modules for slots 1 4 must select one Note Conversion cable is not included s1 s2 s3 and s4 Description ETD Quad E1 T1 with DB25 female connector E1 120 ohms E1 75 ohms T1 software selectable EM Quad E1 75 ohm with mini BNC connector ETR Quad E1 T1 with RJ48C connector E1 120 ohms T1 software selectable m Where pp1 is use
15. ector 15 20 1550 Rx WHE2S WDM mode single bi directional fiber 1550 Tx SC Subscriber Connector 15 20 1310 Rx Optical SFP Module Characteristic for Fast Ethernet FE SFP Optical Module Direction Wavelength nm Connector MHBTW Dual uni directional fiber 1310nm LC PHB2W Dual uni directional fiber 1310nm LC PHB3W Dual uni directional fiber 1310nm LC PHB5W Dual uni directional fiber 1310nm LC PHC8W Dual uni directional fiber 1550nm LC PHCUW Dual uni directional fiber 1550nm LC PHCXW Dual uni directional fiber 1550nm LC PHB3D Dual uni directional fiber 1310nm LC with DDM PHB5D Dual uni directional fiber 1310nm LC with DDM PHC8D Dual uni directional fiber 1550nm LC with DDM PHCUD Dual uni directional fiber 1550nm LC with DDM PHCXD Dual uni directional fiber 1550nm LC with DDM Optical SFP Module Characteristic for Gigabit Ethernet GbE Ae Fiber Direction ig as Connector Distance MTAFW Dual uni directional fiber 850 LC without DDM 550 M MTAFD Dual uni directional fiber 850 LC with DDM 550 M MTBTD Dual uni directional fiber 1310 LC with DDM 2 Km MTBTW Dual uni directional fiber 1310 LC without DDM 2 Km PTB3W Dual uni directional fiber 1310 LC without DDM 30 Km PTB4W Dual uni directional fiber 1310 LC without DDM 40 Km PTC5W Dual uni directional fiber 1550 LC without DDM 50 Km PTC6W Dual uni directional fiber 1550 LC without DDM 60 Km PTC8W Dual uni directional fiber 1550 LC without DDM 80 Km PTCOW Dual uni directional fiber 1550 LC without DDM
16. ommercial 0 to 70 C 100 km SC duplex optical connector WDM mode 1 9 Bi direction Tx 1310 nm Rx 1550 nm commercial 0 to 70 C 15 to 20 km SC simplex optical connector WDM mode 1 9 Bi direction Tx 1550 nm Rx 1310 nm commercial 0 to 70 C 15 to 20 km SC simplex optical connector SFP mini GBIC optical housing daughter card without SFP optical module Combo Gigabit Ethernet GbE daughter card with two RJ45 twisted pair GbE and two SFP mini GBIC optical housing without SFP optical module SFP Optical Module for Fast Ethernet FE SFP 155 Mbps mini GBIC Dual Fiber MHBTW PHB2W PHB3W PHB5W PHC8W PHCUW PHCXW PHB3D PHB5D PHC8D PHCUD PHCXD Multi mode optical module with dual uni directional fiber 155M 1310nm 2Km LC connector w o DDM Fast Ethernet and compliant with ITU G 957 Single mode optical module with dual uni directional fiber 155M 1310nm 15 20Km LC connector w o DDM S 1 1 IR1 Single mode optical module with dual uni directional fiber 155M 1310nm 30Km LC connector w o DDM S 1 1 IR1 Fast Ethernet Single mode optical module with dual uni directional fiber 155M 1310nm 50Km LC connector w o DDM L 1 1 LR1 Fast Ethernet Single mode optical module with dual uni directional fiber 155M 1550nm 80Km LC connector w o DDM L 1 2 LR2 Single mode optical module with dual uni directional fiber 155M 1550nm 100Km LC connector w o DDM L 1 2 LR2Fast Ethernet Single
17. r 7 i di Telecom ANSI Unit Front View a A NSOE SR ni ag a ETSI Unit Front View Features 1U height ETSI unit full front access or ANSI unit front and back access Rack mount wall mount and stand alone WAN ports with 4 hot swappable slots e 4E1 T1 ports per card max up to 16 E1 T1 port per system e E1 T1 is software configurable Tributary ports e Fixed on main board e Up to 4 10 100 Fast Ethernet FE Optional daughter card fixed on panel e 1 Optical FE e 1 Optical FE SFP housing e 2 combo Gigabit Ethernet GbE with 2 RJ45 and 2 SFP housing e 1 DTE V 36 and 1 asynchronous RS232 DTE optional interfaces can be either V 36 RS449 V 35 compatible EIA530 or X 21 Power modules e Hot swappable 48 Vdc plug in modules 36 to 75 Vdc dual for redundancy e AC plug in module 100 to 240 Vac dual for redundancy ANSI only e AC and DC coexistent fixed module 100 to 240 Vac and 36 to 75 Vdc WAN link with virtually concatenated n x E1 T1 where n can be 1 to 16 Encapsulation protocol GFP LAPS and PPP without LCP e Differential delay up to 256ms for E1 and 384ms for T1 e VLAN packet transparency e Packet size up to 12 000 bytes e IEEE 802 1ad Q in Q Timing sources for primary and secondary clocks are any one of E1 T1 DTE internal external manufacture option e Alarm relay e Firmware download to local unit and remote unit Management port and interface e LCD with keypad on ANSI front panel
18. required leave this field blank add2 EXT Description External Clock Note E Where add3 is used to select a LCD display If an LCD display is not required leave this field blank add3 LCD LCD 2 x 16 front panel display Description Note LCD is supported for ANSI unit only Examples 1 Main unit Loop IP6416 S 1UA 4FE ETD ETD ETD ETD SA SD48 EXT LCD Description An ANSI unit with 4 Fast Ethernet FE ports quad E1 T1 with DB25 connector quad E1 T1 with DB25 connector quad E1 T1 with DB25 connector quad E1 T1 with DB25 connector 100 to 240 Vac power 36 to 75 Vdc power external clock and LCD Examples 2 Main unit Loop 1P6416 S 1UA 3FE ETD ETD ETD P9 DTE EXT LCD Description An ANSI unit with 3 Fast Ethernet FE ports quad E1 T1 with DB25 connector quad E1 T1 with DB25 connector quad E1 T1 with DB25 connector 100 to 240 Vac and 48 Vdc 36 to 75 Vdc coexist fixed power supply DTE V 36 RS232 daughter card external clock and LCD Conversion cable Loop ACC CAB DB25M 30 1DB37F Description DB25 pin Male to DB37 Female RS449 conversion cable Length 30 cm Examples 3 Main unit Loop 1P6416 S 1UA 3FE ETD ETD ETD P9 DTE EXT LCD Description An ANSI unit with 3 Fast Ethernet FE ports quad E1 T1 with DB25 connector quad E1 T1 with DB25 connector quad E1 T1 with DB25 connector 100 to 240 Vac and 48 Vdc 36 to 75 Vdc coexist fixed power supply DTE V 36 RS232 daughter card external clock and
19. sion cable mini BNC 75 ohm with optional conversion cable ITU G 823 1 544M bps 32 ppm AMI B8ZS selectable D4 ESF selectable DS1 with 0 7 5 15 dB LBO DS1 with 0 dB to 26 dB ALBO RJ48C DB25 with optional conversion cable Per AT amp T TR 62411 FCC Part 68 SubPart D Layer 2 protocol GFP LAPS and PPP without LCP Tributary Fast Ethernet FE Ethernet Functions Connector Ethernet Bridge Function 10 100BaseT IEEE802 3 Auto negotiation 10 100M Auto MDI MDIX Full or half duplex RJ45 VLAN packet transparency up to 12 000 bytes Support IEEE 802 1q VLAN Support IEEE 802 1ad Q in Q SNMP Ethernet Ethernet Functions Connector 10 100BaseT IEEE802 3 Auto negotiation 10 100M Auto MDI MDIX Full or half duplex RJ45 Tributary Optical Fast Ethernet Speed Connector 100M Base FX FC SC LC Tributary Combo Gigabit Ethernet GbE Speed Connector Tributary DTE V 36 Data Rate Connector Optional Interfaces Tributary RS232 Data Rate Connector Clock Source Primary Clock Secondary Clock 10 100 1000M bps RJ45 for twisted pair GbE LC for optical GbE N x 64K bps N 1 to 128 64K to 8 192M bps DB25 female DCE interface V 36 RS449 via DB25 male to DB37 female conversion cable V 35 compatible DB25 female connector V 35 compatible via DB25 male to M34 female conversion cable EIA530 DB25 female connector X 21 via DB25 male to DB15 female conversion cable Up to 19 2 K