Home

CPC304 User Manual 003 E

image

Contents

1. limax GEN i La HU Weg 83 25 A7 s Z 128 To od dei PAI Lg D amp CN a L SE D J21 J23 857 101 5 CPC304 User Manual 45 2011 Fastwel v 003a E External Connections Fastwel Ley CPC304 4 External Connections The following precautions must be observed to ensure proper installation and to avoid damage to the module other system components or harm to personnel 4 1 Safety Regulations The following safety regulations must be observed when installing or operating the module Fastwel assumes no responsibility for any damage resulting from infringement of these rules Warning When handling or operating the module special attention should be paid to the heatsink because it can get very hot during operation Do not touch the heatsink when installing or removing the module Moreover the module should not be placed on any surface or in any kind of package until the module and its heatsink have cooled down to ambient temperature ESD Sensitive Equipment This product comprises electrostatically sensi
2. Functional Description CPC304 J16 connector Hirose DF13 20DP 1 25V of CPC304 CPC30401 and 03 only is used for connection of LCD panels to single channel LVDS interface using custom adapter cable counterpart connector Hirose DF13 20DS 1 25C with Hirose DF13 2630SCF contacts or using the accessory ACS00037 Only 24 bit panels are supported Table 3 5 LVDS J16 Connector Pinout 1 VDD_EN 11 TxOUT2 2 DISPEN 12 TxOUT2 3 TxOUTO 13 GND 4 TxOUTO 14 GND 5 GND 15 TxOUT3 6 GND 16 TxOUT3 7 TxOUT1 17 GND 8 TxOUT1 18 GND 9 GND 19 TxCLK 10 GND 20 TxCLK Figure 3 5 Connection of Sharp LQ150X1LW72 Panel to CPC304 3 3V External Power To J16 Connector To Interface Connector of CPC304 of LQ150X1LW72 Panel Signal Cont Cont Signal VDD_EN 1 e ii VCC DISPEN 2 2 VCC TxOUTO 3 3 GND TxOUTO 4 E 4 GND GND 5 5 Rx0 GND 6 6 Rx0 TxOUT1 7 7 GND TxOUT1 8 8 Rx1 GND 9 9 Rx14 GND 10 10 GND TxOUT2 11 11 Rx2 TxOUT2 12 12 Rx24 GND 13 13 GND GND 14 14 CK TxOUT3 15 15 CK TxOUT3 16 16 GND GND 17 17 Rx3 GND 18 18 Rx3 TxCLK 19 19 GND TxCLK 20 20 GND Hirose DF13 20DS 1 25C Hirose DF14 20S 1 25C Socket Socket CPC304 User Manual 2011 Fastwel v 003a E 25 Functional Description Fastwel L CPC304 CRT VGA monitor is connected to J18 header IDC 2 mm pitch of CPC304 via a custom adapter cable Leotronics 2040 3102 counterpart
3. The combination 7 marked with red was discovered unstable and is not recommended 3 2 4 1 Connection of External IDE Devices IDE channel is routed to J19 connector of CPC304 Figure 3 2 it is a 44 pin 2 mm pitch header Its pinout is shown in the following table UDMA 100 operation mode is supported with a 10 cm cable only provided that Features Configuration gt IDE UDMA and Custom Configuration gt IDE UDMA 5 options are enabled in BIOS Setup Table 3 2 J19 HDD Connector Pinout 1 RESET 12 DD12 23 JON 34 2 GND 13 DD2 24 GND 35 DAO 3 DD7 14 DD13 25 NOR 36 DA2 4 DD8 15 DD1 26 GND 37 CS1 5 DD6 16 DD14 27 IOCHRDY 38 CS3 6 DD9 17 DDO 28 GND 39 DASP 7 DD5 18 DD15 29 DACK 40 GND 8 DD10 19 GND 30 GND 41 5V 9 DD4 20 31 IRQ 42 5V 10 DD11 21 DRQ 32 CS16 43 GND 11 DD3 22 GND 33 DA1 44 The cable supplied with the module 685611 051 allows direct connection of a 2 5 HDD to the J19 connector Other IDE devices 3 5 HDD CD ROM having 40 contact 2 5 mm pitch connector can be connected to CPC304 via the CDM02 469535 023 adapter This adapter is plugged directly to the 40 contact connector of the IDE device and with 685611 051 cable is connected to CPC304 J19 connector For custom cables it is recommended to use Leotronics 2040 3442 as counterpart connector for J19 CPC304 User Manual 20 2011 Fastwel v 003a E Functional D
4. Functional Description CPC304 3 Functional Description 3 1 Structure and Layout Functional diagram of the CPC304 module is shown in the following figure Figure 3 1 CPC304 Block Diagram Discrete Opto COM1 COM2 PME LPT FDD Apintie Oun RST IRG DE 10 014 DE Tout 5 IDC 26 J23 d KBD MS A Supervisor LPC 6 pin J7 amp WDT 4 Super UO W83627 Winbond LVDS lt 20 pin 32 E a J16 5 5 ISA ao LVDS Sg BIOS2 BIOS1 Transmitter TFT SST49LF008A SST49LF008A E 30 pin F TFT J17 PCI to ISA LPC Bridge VGA Tome VGA IDC 10 SS PME H D f M Buzzer Mic Sa ZS 4 2 pin J8 PCI SE Le AC97 bi Sound D _ Codec In Out ALC203 5 pin J9 AnD CS5536 lt PROS Ethernet Geode LX sys SG Geode Controller 1 y wad Ompanion LU82551IT j j Processor Device IDE ee EI Intel ugi 73 Be oO Lal CF Ethernet A ii J20 Controller 2 PCI amer IDE GN NAND Flash to NF 4 1GB DDR SDRAM Gees Geen FRAM 256 MB FM24CL64 USB1 t t USB2 IDC 10 d A4 J21 Ext LED COM3 COM4 Ces Connector RS422 485 RS422 485 2 pin E 8 pin J30 5 pin J11 5 pin J13 P CPC304 User Manual 2011 Fastwel v 003a E 16 Functional Description Fastwel Een CPC304 CPC304 includes the following main functional units AMD Geode LX 800 500 MHz microprocessor including 32 bit x86 core 64 bit coprocessor 64 bit SDRAM memory bus 256 MB soldered DDR SDRAM system memory Flash memory based res
5. PS 2 keyboard and mouse interface E AC 97 audio Stereo Line In and Line Out microphone input Remote Reset IRQ Discrete remote reset interrupt input 500V optoisolation m RTC z On board real time clock with Li battery backup E Safety System configuration settings stored in CMOS Serial FRAM 5 Possibility of batteryless operation Two watchdog timers with LED indication WDT1 with fixed timeout period of 1 6 s z WDT2 with programmable timeout period from 1 s to 255 min E Discrete I O 8 programmable discrete I O channels E PME Connector for external PME signal source Software Support General Software BIOS Preinstalled FDOS 6 22 operating system 2 Support for MS DOS Windows CE5 0 CE6 0 XPe QNX 6 3x and Linux 2 6 operating systems CPC304 User Manual 14 2011 Fastwel y 003a E Technical Specifications Fastwel Ley CPC304 2 2 Power Requirements The module can be powered either via PC 104 ISA bus or via J24 power connector from an external DC power source providing the following characteristics m Voltage 5 V 5 from 4 75 V to 5 25 V el Consumption current without external devices not more than 1 5 A Important A 12 V voltage is not used by the module 12 V line from power supply connector is routed to the PC 104 header contact Please find important notes on power supply in subsection 3 2 26 of this document 2 3 Environmental a Operating temperature range fro
6. IDC 16 connector set Includes Leotronics 2040 3162 socket for connection to J4 header CPC304 User Manual 11 2011 Fastwel v 003a E Introduction Fastwel EN CPC304 ACS00040 03 IDC 26 connector set Includes Leotronics 2040 3262 socket for connection to J23 header ACS00041 Connector set for diskrete input output connection J5 Includes AMP 1 87499 5 socket and 167021 2 contacts 1 5 Supplementary Information 1 5 1 Related Documents Information related to this product and its components can be found in the following documents Table 1 4 Related Publications CompactFlash cards CF and CompactFlash Specification Revision 1 4 Processor AMD Geode LX Processor Reference Schematic AMD Geode LX Processors Data Book AMD Geode CS5536 Companion Device Preliminary Data Book AMD Geode LX Processor and CS5535 CS5536 Companion Devices Layout Recommendations Super I O Winbond W83627 SuperlO Data sheet CPC304 User Manual 12 2011 Fastwel v 003a E Technical Specifications Fastwel LE CPC304 2 1 Technical Specifications General CPU AMD Geode LX800 500 MHz 32 bit x86 x87 compatible 64 bit coprocessor 64 bit memory bus 64 KB L1 128 KB L2 cache Integrated FPU supports the Intel MMX and AMD 3DNow Technology instruction sets System memory 256 MB soldered DDR SDRAM DDR333 Flash BIOS 2x512 KB reserved In syst
7. xX In two tables above Not used Power supplied to the stacked modules In Out column shows the data transfer direction for a processor module being the bus master 3 2 23 2 PCI Header PC 104 Plus standard specifies availability of 120 pin 80x4 2 mm header P J2 or U49 This interface header accepts 3 stackable PC 104 Plus modules and carries all of the appropriate 32 bit 33 MHz PCI signals PCI signals are available both via the socket at the top side of the module and via a pin array at the bottom side of CPC304 Three PCI bus mastering devices are supported on the P J2 header Figure 3 14 PCI P J2 Connector Contacts Layout E oO a x Si Table 3 24 PCI P J2 Connector Contacts Designation 1 GND Reserved 5V ADOO 2 VI O AD02 ADO1 5V 3 AD05 GND AD04 ADO3 4 C BEO ADO7 GND ADO6 5 GND ADO9 ADO08 GND 6 AD11 VI O AD10 M66EN 7 AD14 AD13 GND AD12 8 3 3V C BE1 AD15 3 3V 9 SERR GND Reserved PAR 10 GND PERR 3 3V Reserved 11 STOP 3 3V LOCK GND 12 3 3V TRDY GND DEVSEL 13 FRAME GND IRDY 3 3V 14 GND AD16 3 3V C BE2 15 AD18 3 3V AD17 GND 16 AD21 AD20 GND AD19 17 3 3V AD23 AD22 3 3V 18 IDSELO
8. 4 Wait until the messages System transferred and COMMAND COM transferred appear CPC304 User Manual 73 2011 Fastwel v 003a E Appendices Fastwel LE CPC304 7 Appendices 7 1 Jumper Settings by Function Table 7 1 Jumper Settings by Function J10 4 2 Enable terminator between D and D lines of COM port in RS485 Terminators on COM3 mode in RS422 RS485 modes J10 3 4 Enable terminator between RX and RX lines of COM port in RS422 mode or in full duplex RS485 mode J12 4 2 Enable terminator between D and D lines of COM4 port in RS485 Terminators on COM4 mode in RS422 RS485 modes J12 3 4 Enable terminator between RX and RX lines of COM4 port in RS422 mode or in full duplex RS485 mode J25 1 2 Enable WDT1 Reset from WDT1 enabled Enable Disable WDTs J25 3 4 Enable WDT2 Reset from WDT2 enabled CompactFlash and J26 3 4 CompactFlash Master NAND Flash Slave NAND Flash operation mode J26 1 2 CompactFlash Slave NAND Flash Master Optoisolated discrete J28 1 3 Remote Reset mode enabled input operation mode ra and PFO signal J28 3 5 2 4 Remote IRQ mode enabled connection J28 4 6 Interrupt enabled on PFO signal The action described in this column corresponds to the closed jumper contacts CPC304 User Manual 74 2011 Fastwel v 003a E
9. Mission complete message BIOS can be upgraded via RS232 COM1 COM2 serial port in console operation mode with the help of fwflash_win exe utility started on a remote PC running Windows XP operating system To do this a Connect for example COM1 port J14 of the module and a COM port of a remote PC with null modem cable and ACS00023 685611 082 adapter cable In BIOS Setup enable the RS232 Manufacturing Link mode on the module make sure that in Custom configuration Menu COM port to which remote PC is connected is selected Manufacturing Mode entered Keyboard Frozen message should appear el On a remote PC running Windows XP select Start gt Run S i Help and Support Search AliPrograms D gt m Run cmd to open the command prompt window E Run fwflash_win exe utility from the command prompt at a remote PC with the following parameters fwflash_win exe FILENAME biosXXX bin COM 1 where biosXXX bin BIOS binary image file name 1 PC COM port number COM1 It is necessary to observe the case The files biosXxxX bin and fwflash_win exe should be located in the same folder with the BIOS binary image file preferably in the root folder CPC304 User Manual 70 2011 Fastwel v 003a E Basic Software Fastwel Ley CPC304 The screen of the remote PC should display the following messages Fastwel Flash Writer Version 1 1 Copyright C 2000 2007 Fastwel Co Ltd Updates Flash B
10. KIB380 is not supplied with the module it is ordered separately External connections are illustrated in Chapter 4 CPC304 User Manual 17 2011 Fastwel v 003a E Functional Description Fastwel Lee CPC304 Figure 3 2 Top Side Connectors and Main Components Layout A5 one rt yan e 5 contro ware weg m gut ul oaet Zum tt n3 au vk Se pap Tei yo ug pisctel Wl Ae WA 8 Mic Bios out 39 ae m ost 3 ciel am Gm eer VE ee GO a AIS K xe cos Hefe op P BA ei W vor oP f BER a Movs AW od V pa 7 Ren powet Vi vele Kon E wor a Saat I E et T T pge H e enerne p per AM ACET gren aS 2 ee guelo op VI geen ion K A powet EP erg ff LS s5538 Ls 3 oer LA um gro 0 4 2 Gg selec ye lc The layout may slightly differ for various versions of the module CPC304 User Manual 18 2011 Fastwel v 003a E Functional Description Fastwel L CPC304 Figure 3 3 Bottom Side Connectors and Main Components Layout VW ye pool ext LED 320 yan FAS The layout may slightly differ for various versions of the board 3 2 Functional Description 3 2 1 Microprocessor The module is based on AMD Geode LX800 microprocessor with 1 8W typical power consumption at 500 MHz maximum power 3 6W TDP The processor includes 32 bit x86 core 64 bit coprocessor and 64 bit DDR memory bus up to 400 MHz graphics and video controller with VGA monitors and LCD panels sim
11. GPIO port lines see subsection 5 9 1 WDT1 can induce Reset only if pins 1 and 2 on J25 pinpad are closed factory setting WDTz2 is a function of Winbond W83627HG SuperlO chip It has programmable timeout period from 1 s to 255 minutes Its setup and control are described in W83627 chip datasheet W83627 padf file on the CD supplied with CPC304 Super IO chip is available via 2Eh port WDT2 can induce Reset only if pins 3 and 4 on J25 pinpad are closed factory setting Operation of each watchdog timer trigger special registers which are available to BIOS function for reading after reboot If SuperlO line GPIO20 is set to logical 1 WDT operated to 0 WDT did not operate The fact of watchdog operation is also reflected by lighting D27 yellow LED 3 2 15 J25 Pinpad J25 pinpad jumpers allow to enable disable inducing Reset by watchdog timers of the module CPC304 is supplied with pins 1 2 and 3 4 closed To disable Reset by a watchdog timer remove the jumper from the appropriate pins Table 3 14 J25 Jumpers Positions 1 2 closed Enable Reset from WDT1 3 4 closed Enable Reset from WDT2 CPC304 User Manual 33 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 3 2 16 J26 Pinpad Compact Flash and NAND flash operation mode master or slave is selected by setting jumpers at J26 pinpad Table 3 15 J26 Jumper Positions 3 4 Compact Flash Master Nand Flash Slave factor
12. The figure below illustrates connection of Sharp LQ104V1DG61 panel to CPC304 module CPC304 User Manual 23 2011 Fastwel v 003a E Fastwel Lee Functional Description CPC304 Figure 3 4 Connection of Sharp LQ104V1DG61 Panel to CPC304 To J17 Connector To Interface Connector of CPC304 of LQ104V1DG61 Panel Signal Cont Cont Signal GND 1 1 GND DOT _CLK 2 2 CK HSYNC 3 3 HSYNC VSYNC 4 4 VSYNC GND 5 5 GND RO 6 6 RO R1 7 7 R1 R2 8 8 R2 R3 9 9 R3 R4 10 10 R4 R5 11 11 R5 GND 12 12 GND GO 13 13 GO G1 14 14 Gi G2 15 15 G2 G3 16 16 G3 G4 17 17 G4 G5 18 18 G5 GND 19 19 GND BO 20 20 BO B1 21 21 B1 B2 22 22 B2 B3 23 23 B3 B4 24 24 B4 B5 25 25 B5 GND 26 26 GND DISPEN 27 27 ENAB 3 3V 28 28 VCC 3 3V 29 29 VCC GND 30 30 R L AMP 1 111196 9 31 U D Socket Hirose DF9 31S 1V 32 Socket CPC304 User Manual 2011 Fastwel v 003a E 24 Fastwel Lee
13. devices two external hard drives connected via on board connectors CompactFlash card or soldered on board 1 GB flash disk For data exchange CPC304 uses up to two independent Fast Ethernet ports up to four COM ports two USB 2 0 ports and eight programmable discrete input output lines System control and management capabilities of CPC304 include two watchdog timers opto isolated remote Reset IRQ input external signal system wake up controller reserved BIOS and possibility to save system configuration and emergency parameters in FRAM chip CPC304 is designed for operation within industrial temperature range from 40 C to 85 C CPC304 is manufactured in three versions CPC30401 full function version CPC30402 light weight version without LVDS interface and on board 1 GB NAND flash disk with one Fast Ethernet channel and three COM ports CPC30403 is a variant of CPC30401 Coated version with extended operating temperature range CPC304 is supplied with the preinstalled FDOS 6 22 operating system and supports MS DOS Windows CE5 0 CE6 0 XPe as well as QNX 6 3x and Linux 2 6 operating systems CPC304 User Manual 9 2011 Fastwel v 003a E Introduction Fastwel Lee CPC304 Figure 1 1 CPC304 Module Appearance The appearance may vary for different versions of the module 1 2 CPC304 Versions At the present time the CPC304 module is manufactured in three basic versions differing in interface
14. 003a E Fastwel Le CPC304 7 Appendices 7 1 List of Tables Table 1 1 Table 1 2 Table 1 3 Table 1 4 Table 3 1 Table 3 2 Table 3 3 Table 3 4 Table 3 5 Table 3 6 Table 3 7 Table 3 8 Table 3 9 Table 3 10 Table 3 11 Table 3 12 Table 3 13 Table 3 14 Table 3 15 Table 3 16 Table 3 17 Table 3 18 Table 3 19 Table 3 20 Table 3 21 Table 3 22 Table 3 23 Table 3 24 Table 3 25 Table 3 26 Table 3 27 Table 3 28 Table 5 1 Table 5 2 Table 5 3 Table 5 4 Table 5 5 Table 5 6 Table 5 7 Table 5 8 Table 7 1 EE E EE 74 Jumper Settings by FUNCHON iciececiniauainina a a E E eae E E A O 74 CPG304 Ee EEN 10 CPC304 Supplied Get 11 CPC304 Additional ACCESSOLICS cei tr in tr ieee e een aee tees eetennaeeeeeeeneneea 11 Related Publtcagons eee eee eee teen a d a E E 12 IDE Channel Devices Connection Variants cccieeceeeeteecneee rete eee eeciaeeeeeeeeeteciaaeeeeeeeeteenaaeees 20 J19 HDD Connector Hip 3u eu siegeeeeng EENS 20 J20 CompactFlash Socket Pinot 21 TP EJI Header PINoU E 23 LVDS J16 Connector Pinot 25 VGA J18 Connector Pinot 26 J4 Ethernet Header Pinot 26 J21 Connector PINOUT ncachawh e de dE a E E aan eee 27 LPT FDD J23 Connector Pinot 27 J14 and J15 Pin Assignments 1 0 0 0 cece e reece ttre tree reer eee e eee rere aaaee seer teecaaeeeeeeeeteencaaeeeeeeees 29 J11 and J13 Contact Assignments cece ee cence eter eee eettee teeter e
15. 2 4 3 NAND Flash The capacity of the soldered on board NAND flash memory chip is 1 GB CPC30401 and CPC30403 only The generations of the module below 1 3 have 128 MB NAND flash memory with no UDMA support This flash drive can be used as a bootable disk or can be disabled in BIOS Setup NAND flash disk contains the preinstalled FDOS 6 22 operating system compatible with MS DOS 6 22 and some software utilities providing operational availability of the module NAND flash chip is connected to IDE controller via SM223AT IDE to NAND flash bridge and uses a standard IDE driver The other operating systems require installation of an appropriate driver which can be found on the CD supplied with the module Compact Flash and NAND flash operation mode master or slave is selected by setting jumpers at J26 pinpad 1 2 closed NAND flash Master CF Slave 3 4 closed CF Master NAND flash Slave 3 4 is the factory setting Note For generations of the module below 1 3 In case the NAND flash chip is not used Onboard NAND Flash option in BIOS setup is set to Disable the jumper at J26 pinpad should be removed or set to the position 3 4 Note A In case the NAND flash chip is not used Onboard Flash Disk option in BIOS setup is set to Disable it is possible that some CompactFlash cards will operate only in one mode Master or Slave For correct operation it is necessary to set the required configuration using J26 jumper switch an
16. EQU 02302h Page register of DMA 3 After replacement of addresses the DDMA programming for reading differs only in the DMA request enabling procedure Enable DMA3 request mov DX DMA_MULTIMAS Mask register mov AL 0 Reset mask command out DX AL Enable DMA request According to the IT8888G bridge documentation the channel mask register is not used instead of it it is recommended to use Multimask register for all channels writing O or 1 to it the same way as for channel 0 DDMA controller allows to simplify programming of channel registers by writing words to data registers Besides 32 bit addressing is allowed mov AL 46h DMA reading mode mov DX DMA MOD DMA controller mode register out DX AL Gl Set counter for bytes read from AX mov DX DMA3CNT DMA 3 channel counter register out DX AX Set the value of the counter Set 0 31 address bits from n3 CX BX mov DX DMA3ADR Buffer address register for DMA 3 channel mov AX BX Put lower address bits to AX out DX AX Set lower address word mov AX BX Put 16 31 address bits to AX mov DX DMAPG3 Channel 3 page register address out DX AL Set higher address word Enable DMA request mov DX DMA_MULTIMAS Mask register mov AL 0 Reset mask command out DX AL Enable DMA request In DDMA controller programming an additional pause for bus recovery after input output operations is not required CPC304
17. GND IDSEL1 IDSEL2 19 AD24 C BE3 VI O IDSEL3 20 GND AD26 AD25 GND 21 AD29 5V AD28 AD27 22 5V AD30 GND AD31 23 REQO GND REQ1 VIO CPC304 User Manual 2011 Fastwel v 008a E 40 Functional Description Fastwel LE CPC304 24 GND REQ2 5V GNTO 25 GNT1 VI O GNT2 GND 26 5V CLKO GND CLK1 27 CLK2 5V CLK3 GND 28 GND INTD 5V RST 29 12V INTA INTB INTC 30 12V REQ3 GNT3 GND A Attention The module itself does not supply 3 3V power to the contacts marked with in the table above These contacts are used to supply 3 3V power to PC 104 Plus expansion modules from an external PC 104 Plus power supply unit 3 2 24 Power Supply The power is supplied to CPC304 via PC 104 connector or via dedicated J24 connector from a power source with characteristics specified in section 2 2 Figure 3 15 J24 Power Supply Connector 20 34 Table 3 25 1 ica The main power voltage of the processor module is 5V 5 ae 12 V is supplied via J24 connector for use by PC 104 expansion sien modules but is not used in CPC304 The following table gives assignments of J24 contacts J24 Power Connector Pinout 5 V GND GND 2 3 4 12 V For making a custom power cable it is recommended to use AMP 4 171822 4 socket with 170263 1 contacts or ACS00038 accessory Important A If PC 104 or PC 104 Plus expansion modules with aggregate consumption
18. User Manual 68 2011 Fastwel v 003a E Basic Software Fastwel EN CPC304 6 Basic Software 6 1 Supplied Software The module is supplied ready for operation with the pre installed FDOS 6 22 operating system compatible with MS DOS 6 22 FDOS and some service utilities FWFLASH for example are located at the on board flash disk To use the module with other operating systems the appropriate drivers should be installed The CD supplied with the module contains necessary service software utilities such as CMOS_RST FWFLASH and drivers remdisk sys and others including the drivers necessary to run the supported operating systems 6 2 Reset CMOS to Factory Defaults from a Remote PC H current BIOS parameters do not provide normal operation of the module and the BIOS Setup program can not be started to change incorrect settings use CMOS_RST cmos_rst com software utility which allows to reset the BIOS setup parameters stored in CMOS memory to factory defaults from a remote PC To do so follow the procedure below 1 Connect COM1 port J14 of the switched off CPC304 to a PC COM port with a null modem cable and ACS00023 685611 082 adapter cable 2 Start cmos_rst comona remote PC using MS DOS with the parameter CMOS_RST COM COM2 where COM2 is a name of a PC COM port to which the module is connected The following message is displayed on the PC monitor Remote CMOS Reset Version 2 1 Copyright C 2000 2005 Fastwel Inc se
19. again with the module power switched on Do not switch the power off It is possible to abort operation of fwflash exe or fwflash_win exe by pressing lt Esc gt at a PC keyboard only before the first BIOS file segment 64 KB is transmitted Important If the module is operated with different BIOS versions in the main and the reserve storage BIOS Setup parameters can be possibly reset to factory defaults when switching between the main and the reserve BIOS copies To avoid this it is necessary to have identical BIOS versions on both chips This can be achieved by using either fwflash exe Or copy2res com utilities as described above Important It is not allowed to use BIOS files other than explicitly specified by Fastwel as suitable for this purpose CPC304 User Manual 72 2011 Fastwel v 003a E Basic Software Fastwel EN CPC304 6 4 Manufacturing Link Mode Manufacturing Link mode allows to exchange files between the module and a remote PC via RS232 link The COM port number for operations in Manufacturing Link mode is set by Console MFG Port parameter in Custom Configuration menu of BIOS Setup see section 5 5 of this Manual To exchange files the driver remdisk sys should be loaded into memory of a PC running MS DOS 6 22 This make the disk drives of the CPC304 available at the remote PC as logical units The config sys initialization string for loading remdisk sys into PC memory should look like this DEVI
20. capabilities and coating In this Manual the notes related to the CPC30401 and CPC30402 basic versions apply to their coated variants as well The version CPC30403 Coated is a variant of CPC30401 with widened operating temperature range and protective coating Table 1 1 CPC304 Versions 2 CPC30401 COM3 COM4 CPC30401 Coated COM3 COM4 40 C to 85 C CPC30402 COM3 CPC30402 Coated COM3 CPC30403 Coated 50 C to 85 C COM3 COM4 CPC304 User Manual 2011 Fastwel v 003a E Introduction Fastwel Ley CPC304 1 3 Delivery Checklist Table 1 2 CPC304 Supplied Set CPC30401 CPC30401 Coated CPC30402 CPC30402 Coated CPC30403 Coated 467444 013 CPC304 processor module 467444 013 01 467444 013 02 467444 013 03 467444 013 04 CDM02 469535 023 Adapter module for connection of 3 5 HDD or CD ROM drive 685611 051 Cable for 2 5 HDD connection to 44 contact header 469539 012 Lithium battery assembly p n CR2032 1F4 DART ACS00023 68561 1 082 DB9F to IDC10 adapter cable for connection to COM1 or COM2 ports Mounting standoffs kit Jumpers set 467369 009 CD ROM with documentation and service software Antistatic bag and consumer carton box A Note Keep the antistatic bag and the original package at least until the warranty period is over It can be used for future storage or warranty shipments 1 4 Addit
21. remote PC via RS232 link To exchange files the driver remdisk sys should be loaded into PC memory it is described in section 6 4 of this document fwflash exe and fwflash_win exe utilities operation is described in section 6 3 The COM port number for operations in Manufacturing Link mode is set by Console MFG Port parameter in Custom Configuration see section 5 5 of this Manual CPC304 User Manual 59 2011 Fastwel v 003a E General Software BIOS Fastwel LE CPC304 5 9 2 Reset CMOS to Last Known Values If you changed your mind and decided not to write the changes you have made in BIOS Setup program and have not yet saved the values in CMOS memory you may select this command to return to the last saved parameters i e to those with which the system was successfully booted last time and continue with BIOS Setup On selection of this command the following message appears Reset CMOS to last known values Y N Pressing Y resets the parameters in CMOS memory and returns you to the Main menu N returns you to the Main menu without making any changes 5 9 3 Reset CMOS to Factory Defaults To reset the BIOS parameters to the values defined by the manufacturer select this Main menu command The program responds with this message Reset CMOS to factory defaults Y N Pressing Y resets the values stored in CMOS to the factory defaults and returns you to the Main menu N returns you to the M
22. socket or using the accessory ACS00040 01 It is also possible to connect VGA monitor to VGA D Sub connector J16 of KIB380 interface module In this case J18 CPC304 and J15 KIB380 headers are connected with the adaptor cable supplied with KIB380 module The table below shows J18 header pinout Table 3 6 VGA J18 Connector Pinout 1 RED 6 GND 2 GND 7 HSYNC 3 GREEN 8 VSYNC 4 GND 9 5 BLUE 10 3 2 6 Fast Ethernet Interface The CPC304 has two one for CPC30402 10 100Base T independent Ethernet channels provided by two Intel LU82551IT controllers Both Ethernet ports are available via one 16 pin 2 mm pitch IDC header J4 on the top side of the board see Figure 3 2 Ethernet channels are connected to this header via custom adaptor cable with Leotronics 2040 3162 counterpart connector or ACS00040 02 accessory Table 3 7 J4 Ethernet Header Pinout 1 LAN1_TX 9 LAN2_TX 2 LAN1_TX 10 LAN2_TX 3 LAN1_RX 11 LAN2_RX 4 NC 12 NC 5 NC 13 NC 6 LAN1_RX 14 LAN2_RX 7 NC 15 NC 8 NC 16 NC Both channels are available via standard RJ45 connectors on KIB380 interface expansion module In this case Ethernet channels are connected directly to J9 LAN1 and J12 LAN2 RJ45 connectors of KIB380 J4 CPC304 header is connected to J8 KIB380 header using the adapter cable supplied with KIB380 Please refer to the connections diagram in Chapter 4 CPC304 User Manual 2
23. to the Main menu without making any changes 5 10 Extended BIOS Functions 5 10 1 ADM706T Supervisor Chip Based Watchdog Timer Control WDT1 is a watchdog timer with fixed timeout period of 1 6 s it is a part of the ADM706T U63 Supervisor IC After completion of POST Power On Self Test WD1 watchdog timer is disabled User can control this WDT in one of the two ways x Using INT 17h BIOS extension Gi Using GPIO port lines of the SuperlO W83627HG U15 Setting the GPIO22 line to 1 enables WDT1 0 disables it GPIO30 line is used for strobing Attention A For correct programming of the WDT1 watchdog timer and SuperlO GPIO port lines please refer to the SuperlO datasheet W83627 pdf on the CD supplied with the module 5 10 1 1 Using INT 17H BIOS Extension to Control the Watchdog Timer WDT enable Input AH FDh mov ax OFDO1h AL OLH mov dx OFFFFh DX FFFFh int 17h Output No WDT disable Input AH FDh mov ax OFDO3h AL 03h mov dx OFFFFh DX FFFFh int 17h Output No WDT strobing Input AH FDh mov ax OFDO2h AL 02h mov dx OFFFFh DX FFFFh int 17h Output No CPC304 User Manual 61 2011 Fastwel v 003a E General Software BIOS Fastwel LBs CPC304 5 10 2 SMI Control It is possible to temporarily disable SMI for example for manipulations with precise timing diagrams User can control SMI using INT 17h BIOS extension SMI disable Input AX DOOOh mov ax 0D000h DX FF
24. 0h 026Fh External ISA bus External bus access 0270h 02E7h Reserved No access 02E8h 02EFh COM4 RS422 485 02F0h 02F7h Reserved No access 02F8h 02FFh COM2 RS232 0300h 033Fh External ISA bus External bus access 0340h 035Fh External ISA bus or not available This range is not available when COM3 and COM4 are disabled in BIOS Setup 0360h 0377h Reserved No access 0378h 037Fh LPT1 0380h O3AFh Reserved No access 03B0h 03DFh Video O3E0h 03E7h Not available or External ISA bus This range is available only when COM3 and COM4 are disabled in BIOS Setup O3E8h O3EFh COMS or External ISA bus RS422 485 When COM3 and COM4 are disabled in BIOS Setup external ISA bus access 03F0h 03F5h FDD Controller 03F6h Reserved No access 03F7h FDD Controller 03F8h 03FFh COM1 RS232 0400h FFFFh External ISA bus External bus access OCF8H OCFFh Host PCI controller configuration registers 2011 Fastwel v 003a E Functional Description Fastwel L CPC304 3 3 3 Interrupt settings By default interrupts are generated by the devices belonging to the CPC304 module Among the alternative interrupt generating devices are expansion modules on ISA or PCI bus PC 104 and PCI 104 connectors optoisolated Reset input PFO signal Table below presents interrupt settings Interrupt request configuration is performed in BIOS Setup Ta
25. 2 485 Transmitters Control Ports COM3 COM4 Ports COM3 and COM4 RS 422 485 transmitters are controlled via GPIO5 and GPIO6 channels of CS5536 companion To switch RS 422 485 transmitters on and off it is necessary to set these channel Please s to logical 1 or O respectively find below the GPIO control functions program code fragments Borland C 3 1 MS DOS Function void gpio_low_out_en BYTE gpio_num Purpose Sets the given GPIO to output mode Parameters gpio_num GPIO number void gpio_low_out_en BYTE gpio_num vo DWORD val val inpd gpio_bat4 val DWORD 1 lt lt gpio_num val amp DWORD 1 lt lt gpio_num 16 outpd gpio_bat 4 val j Function void gpio_low_set_value BYTE gpio_num BOOL value Purpose Switches GPIO with specified number on off Parameters gpio_num GPIO number id gpio_low_set_value BYTE gpio_num BOOL value DWORD val val inpd gpio_ba if value val DWORD 1 lt lt gpio_num val amp DWORD 1 lt lt gpio_num 16 else val amp DWORD 1 lt lt gpio_num val DWORD 1 lt lt gpio_numt 16 outpd gpio_ba val For the above program code samples the parameter gpio_ba should be described this way UINT gpio_ba 0xF000 for BIOS v 1 2 or UINT gpio_ba 0xEC00 for BIOS v 3 4 0 and above Attention A When developing appl
26. 2 CompactFlash Socket srsineiraiiia ii a AE AE EE SAASTA SEE 21 3 2 4 3 NAND FlaShwusicwsncausoatbniin iain A E E EA 22 3 2 5 Video Controller and Connection of Monitors ssesseeeeseseeeseirretesetierrrtnsstttrrnnnrssetrrnrnnnnseent 23 3 2 6 Fast Ethernet Interface 26 3 2 7 Deet ete eee eee eee eet E E cette 27 3 2 8 FDD LPT EE 27 3 2 9 E TEE 28 3 2 9 1 COM and COM2 RS232 ccccccccececceceeeeeceeeeeeaeeeeeceeeeetecaeeeesecaeeeetenseeeeseneeettes 28 3 2 9 2 COM3 and COM4 RS485 RS422 eee eee eect eee eee eeneeeeeeeeetenaeeeeeeeeeneea 29 3 2 10 PS 2 Keyboard and Mouse Interface 31 3 2 11 Audio Viel EE 32 3 2 12 Optoisolated Reset IRQ Input 32 3 2 13 RTG and GMOS Serial ERAN ERENNERUNG 33 3 2 14 Watchdog Timers issaicecscecetnnanscecsietciacgay sptdesteensinegauls bods eneagnvct stents enesaidavadentvesseaguecadentvertnansuetens 33 3 2 15 J25 PUM DA EE 33 3 2 16 J26 Pinpad ees a eae Me oe oh de eee 34 CPC304 User Manual 1 2011 Fastwel v 003a E Fastwel Lee CPC304 S247 Eier Bingen 34 3 2 18 Discrete Input Output EEN 35 3 2 19 External PME Signal Connechor ee teecaaeeeeeeeetneiaaeeeeeeeeneenaaeees 35 3 2 20 Battery Comnnechor 000 0 eee nn reer aaee tree ee tnenaaeeeeeeeetnenaaeees 36 3 2 21 Diagnostic TTT 36 3 2 22 ee EELER 37 3 2 23 Expansion Buses ISA and EC seiss seess AE veda dan AE ee Ee Ee 38 S223 USA TEE 38 3 2 23 2 e E TEE A0 3 2 24 Power SUDDIY siscisi
27. 4 IOR Out A15 SA16 Out B15 DACK3 Out A16 SA15 Out B16 DRQ3 In A17 SA14 Out B17 DACK1 Out CPC304 User Manual 38 2011 Fastwel v 003a E Fastwel Lee Functional Description CPC304 A18 SA13 Out B18 DRQ1 In A19 SA12 Out B19 REFRESH Out A20 SA11 Out B20 BCLK Out A21 SA10 Out B21 IRQ7 In A22 SA9 Out B22 IRQ6 In A23 SA8 Out B23 IRQ5 In A24 SA7 Out B24 IRQ4 In A25 SA6 Out B25 IRQ3 In A26 SA5 Out B26 DACK2 Out A27 SA4 Out B27 TC Out A28 SA3 Out B28 BALE Out A29 SA2 Out B29 5V Power A30 SA1 Out B30 OSC Out A31 SAO Out B31 GND Power A32 GND Power B32 GND Power Table 3 23 ISA P J1 Rows C and D Contacts Designation co GND Power DO GND Power C1 SBHE Out D1 MEMCS16 In C2 LA23 Out D2 NOCS16 In C3 LA22 Out D3 IRQ10 In C4 LA21 Out D4 IRQ11 In C5 LA20 Out D5 IRQ12 In C6 LA19 Out D6 IRQ13 In C7 LA18 Out D7 IRQ14 In C8 LA17 Out D8 DACKO Out c9 MEMR Out D9 DRQO In C10 MEMW Out D10 DACK5 Out C11 SD8 In Out D11 DRQ5 In C12 SD9 In Out D12 DACK6 Out C13 SD10 In Out D13 DRQ6 In C14 SD11 In Out D14 DACK7 Out C15 SD12 In Out D15 DRQ7 In C16 SD13 In Out D16 5V Power C17 SD14 In Out D17 MASTER In C18 SD15 In Out D18 GND Power C19 KEY D19 GND Power CPC304 User Manual 2011 Fastwel v 003a E 39 Fastwel Lee Functional Description CPC304 Note
28. 4 Features Configuration Features Configuration menu screen is shown on the following figure Figure 5 3 Features Configuration Menu Screen System BIOS Setup Custom Configuration C 2005 General Software Inc All rights reserved ACPI 1nd Enabled Advanced Power Management Enabled POST Memory Manager Disabled IDE UDMA Enabled UsbMassStorage Enabled Usb20 gt Disabled 1 lt CR gt lt Tab gt to select or lt PgUp gt lt PgDn gt to modify lt Esc gt to return to main menu The figure shows the default settings Features Configuration menu items are described in the table below Table 5 3 Features Configuration Menu Items Menu Item Options Description ACPI 1 0 Enabled ACPI features support for OS Windows Linux Disabled Enabled by default POST Memory Manager Disabled POST procedures skipped default Enabled POST enabled USBMassStorage Enabled USB disk drives support enabled by default Disabled Advanced Power Management Enabled APM support advanced power supply units management Disabled Enabled by default IDE UDMA Disabled Enables disables UltraDMA mode for Primary IDE channel Enabled Disabled by default USB20 Enabled USB 2 0 devices support disabled by default Disabled Remember Wrong or incorrect settings may lead to abnormal system performance To correct possible errors restart the BIOS Setup program and restore manufacturer s settings by selection
29. 6 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 3 2 7 USB Interface Figure 3 6 J21 IDC10 Pins Numbering 10 l The module is equipped with two USB 2 0 host ports Each channel has separate power control circuit eo Oh One USB device may be connected to each port 1 9 USB drive boot is supported Both ports are available via IDC10 2 mm pitch header J21 USB devices can be connected to J21 header using a custom adaptor cable with Leotronics 2040 3102 counterpart connector or using ACS00040 01 accessory Table 3 8 J21 Connector Pinout 1 USB1_ 5V 6 USB2_DAT 2 USB2_ 5V 7 USB1_GND 3 USB1_DAT 8 USB2_GND 4 USB2_DAT 9 5 USB1_DAT 10 USB devices can also be connected to CPC304 via KIB380 interface expansion module which has two standard 4 contact Type A USB connectors USB1 J4 and USB2 J5 In this case J21 header of CPC304 is connected to J2 header of KIB380 with the adaptor cable supplied with KIB380 Please refer to the connections diagram in Chapter 4 3 2 8 FDD LPT Port J23 is a 26 pin 2 mm pitch IDC connector shared by LPT and FDD ports Switching between LPT and FDD ports is performed in BIOS Setup LPT port of CPC304 supports EPP and ECP operation modes ECP amp EPP 1 7 is the default mode The operation modes are switched in BIOS Setup LPT uses IRQ7 interrupt line IRQ6 is assigned to FDD port Interrupts from these ports can be disabled and sw
30. CE C remdisk sys COMn XXXX where COMn PC COM port number COM1 default COM2 XXXX Data transfer rate 9600 or 115200 default Mbit s After initialization of the driver remdisk sys and selection of Start RS232 Manufacturing Link command in BIOS Setup a new logical device D appears at the PC corresponding to C drive of the module Manufacturing Link mode can also be used for formatting of the CPC304 disks and transferring of MS DOS 6 22 or FDOS 6 22 operating systems To format a CPC304 disk and to transfer MS DOS operating system 1 Boot a PC with the operating system which is to be transferred onto a CPC304 disk and start the Manufacturing link mode at the module 2 On the PC enter the command FORMAT Z S where z isa CPC304 drive name S operating system transfer option 3 Wait until the message System transferred appears To format a CPC304 disk and to transfer FDOS 6 22 operating system 1 Copy the FDOS system folder to a PC Establish a connection between CPC304 and a PC in Manufacturing Link mode 2 If Windows is running on the PC enter the following command LOCK Z where z stands fora CPC304 disk name 3 From FDOS system directory file attributes System and Hidden removed on the PC enter the next command SYS Z ZE C where Z is a CPC304 drive name E FDOS 6 22 operating system files transfer option C command com transfer option
31. CI INT C Assignment IRQ10 IRQ10 or IRQ11 PCI INT D Assignment IRQ11 CPC304 User Manual 56 2011 Fastwel v 003a E CPC304 General Software BIOS Fastwel Lee PFO OPTO gt IRQ Disabled IRQ3 IRQ4 IRQS IRQ6 IRQ7 IRQ8 IRQQ IRQ10 IRQ11 IRQ12 IRQ13 IRQ14 IRQ15 The interrupt at a selected line is generated upon PFO signal as well as on optoisolated remote reset input Disabled by default LPT Mode ECP amp EPP 1 7 ECP amp EPP 1 9 ECP EPP 1 7 amp SPP EPP 1 9 amp SPP SPP bi dir Standard LPT port operation mode ECP amp EPP 1 7 default IRQ3 come ISA IRQ3 IRQ3 interrupt source selection COM2 default IRQ4 COM1 ISA IRQ4 IRQ4 interrupt source selection COM1 default IRQS PCI ISA IRQ5 IRQ5 interrupt source selection PCI device default IRQ6 FDC ISA IRQ6 IRQ6 interrupt source selection floppy disk controller default IRQ7 LPT ISA IRQ7 IRQ7 interrupt source selection LPT port default IRQ9 ACPI ISA IRQ9 IRQQ interrupt source selection ACPI controller default IRQ10 PCI ISA IRQ10 IRQ10 interrupt source selection PCI device default IRQ11 PCI ISA IRQ11 IRQ11 interrupt source selection PCI device default IRQ12 PS2 Mouse ISA IRQ12 IRQ12 interrupt source selection PS 2 mouse default IRQ14 IDE ISA IRQ14 IRQ14 interrupt sourc
32. CPC30402 version has COM only The jumpers of the J10 for COM and J12 for COM4 pinpads connect terminators to RS485 RS422 signal lines see table Jumper Settings The pins of these pinpads have identical designation shown in the following figure Pins 1 2 are connected at the factory Figure 3 8 J10 and J12 Pinpads 2 4 1 3 RX RX T erminatorEnabled TX T X T erminatorEnabled To use COM or COM4 ports in RS422 or RS485 mode do the following Set jumpers on the pinpad corresponding to the port Initialize the port by software Figure below shows two modules connected in RS422 mode The jumper connecting terminator is set on receive lines only lines RX and RX In RS485 mode the terminators are connected only on devices at the ends of the line on the next figure The terminators resistance is 120 Ohm CPC304 User Manual 29 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 Figure 3 9 Point to Point Connection of Two Modules in RS422 Mode tt J13 J10 J12 1 2 Connector S10 J12 1 2 RS 422 RS 485 Converter RS 422 RS 485 Converter J10 J12 3 4 J10 J12 3 4 Figure 3 10 Connection of Several Devices in RS485 Mode ona J10 J12 1 2 RS 422 RS 485 Converter 120 J11 S13 TX Connector as Peripheral Module i EN off J10 J12 3 4 Terminating Module on 10 12 1 2 Peripheral Module RS 422 RS 485 Converter 120 RS 485 Conve
33. FFh mov dx OFFFFh Output No int 17h SMI enable Input AX DOOLh mov ax ODOOI1h DX FFFFhA mov dx OFFFFh Output No int 17h 5 10 3 FRAM Memory Access User applications can access free FRAM cells using INT 17h BIOS extension FRAM volume available to user programs is 7 KB To read the following input parameters should be set ah 0 bx Address offset in FRAM area available to user application 0 1BFFh cx The number of bytes to read dx 4657h FW es di The buffer for the read data To write set the following input parameters ah 1 bx Address offset in FRAM area available to user application 0 1BFFh cx The number of bytes to write dx 4657h FW ds si The buffer for the data to write On operation completion the functions return the result in C flag CF NC OK CY Error CPC304 User Manual 62 2011 Fastwel v 003a E General Software BIOS Fastwel EN CPC304 5 10 4 User LEDs Control LED1 D11 and LED2 D12 user LEDs are switched on and off by setting the appropriate W83627HG SuperlO GPIO line to logical 0 or 1 respectively LED1 GP1IO23 0 1 LED2 GPIO35 0 1 Attention A For correct programming of the SuperlO GPIO port lines please refer to the SuperlO datasheet W83627 pdf on the CD supplied with the module CPC304 User Manual 63 2011 Fastwel v 003a E General Software BIOS Fastwel EN CPC304 5 10 5 RS 42
34. Fastwel LE CPC304 PC 104 Plus AMD Geode LX 800 Based Processor Module User Manual Rev 003a E November 2011 Product Title CPC304 Document name CPC304 User Manual Manual version 003a E Ref doc v 1 5 R 467444 013 Copyright 2008 2009 2010 2011 Fastwel Co Ltd All rights reserved Revision Record 001 Initial preliminary version CPC304 January 2008 001a Delivery checklist corrected document structure changed CPC304 August 2008 002 BIOS Setup chapter added Block diagram and board layout diagram CPC304 June 2009 corrected all chapters reworked 003 Changes mainly following the release of v 1 3 of the module BIOS Setup CPC304 July 2010 section changed DDMA programming added BIOS upgrade section revised several illustrations added or corrected multiple text changes 003a J17 TFT pinout corrected CPC304 November 2011 Contact Information Fastwel Co Lid Fastwel Corporation US Address 108 Profsoyuznaya st 45 Main Street Suite 319 Moscow 117437 Brooklyn New York 11201 Russian Federation USA Tel 7 495 232 1681 1 718 554 3686 Fax 7 495 232 1654 1 718 797 0600 Toll free 1 877 787 8443 1 877 RURUGGED E mail info fastwel com Web http www fastwel com Fastwel Ley CPC304 Table of Contents Table of Contents eegene ene 1 ister lables E T E EE E E E E innit ne 3 List Of FIGUES EE 4 Notation e lu e EE 5 General Safety EE 6 Unpa
35. GND 3 GND 4 Lin Out H 5 Lin_Out_L Audio devices can also be connected to CPC304 using KIB380 interface module via its standard 3 5 mm audio connectors Audio In J24 Audio Out J26 and Mic J22 J9 and J8 audio connectors of CPC304 are connected to J25 and J23 connectors of KIB380 respectively using the interface cables supplied with KIB380 interface module as shown in the connections diagram in Chapter 4 3 2 12 Optoisolated Reset IRQ Input J27 is a 2 pin JST 2 mm pitch header that is intended for connection of a remote Reset IRQ signal source with voltage of 3 to 5 V The discrete input has 500 V optoisolation Optoisolated Reset circuitry sample is shown in the figure below Figure 3 11 Discrete Input Optoisolation Optoisolated Reset Input gt Si 1 Reset E Ter yer A E 470 gt 2 GND For making a custom cable it is recommended to use as a counterpart connector JST PHR 2 socket with JST SPH 002T P0 5S contacts for crimping see ACS00031 03 accessory J28 pinpad is used to switch between the discrete input operation modes Reset input or IRQ input Closing contacts 3 5 and 2 4 enables IRQ input closing contacts 1 3 factory setting enables Reset input closing 4 6 enables IRQ on PFO see Custom Configuration section CPC304 User Manual 32 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 3 2 13 RTC and CMOS Serial FRAM The modu
36. H the product contains socketed components they should be inspected to make sure they are seated fully in their sockets CPC304 User Manual 7 2011 Fastwel v 003a E Fastwel Ley CPC304 Handling In performing all necessary installation and application operations please follow only the instructions supplied by the present manual In order to keep Fastwel s warranty you must not change or modify this product in any way other than specifically approved by Fastwel or described in this manual Technical characteristics of the systems in which this product is installed such as operating temperature ranges and power supply parameters should conform to the requirements stated by this document Retain all the original packaging you will need it to pack the product for shipping in warranty cases or for safe storage Please pack the product for transportation in the way it was packed by the supplier When handling the product please remember that the module its components and connectors require delicate care Always keep in mind the ESD sensitivity of the product Three Year Warranty Fastwel Co Ltd Fastwel warrants that its standard hardware products will be free from defects in materials and workmanship under normal use and service for the currently established warranty period Fastwel s only responsibility under this warranty is at its option to replace or repair any defective component part of such products free of c
37. IOS and or Node ID on CPU686 series module Trying switch on manufacturing mode Manufacturing mode OK Segment address Sending OK Erasing OK Writing OK Segment address Sending OK Erasing OK Writing OK Segment address Sending OK Erasing OK Writing OK Segment address Sending OK Erasing OK Writing OK Segment address Sending OK Erasing OK Writing OK Segment address Sending OK Erasing OK Writing OK Segment address Sending OK Erasing OK Writing OK Segment address Sending OK Erasing OK Writing OK Oxfff80000 Oxff 90000 Oxfffa0000 OxfffbO0000 OxfffcO0000 Oxfffd0000 Oxfffed0000 Oxffff0000 If you see the command line the BIOS is successfully upgraded Reboot to enable the upgraded BIOS copy The Copy2Res com utility is used for copying BIOS from the main storage to Reserve To do so run this utility under MS DOS or FDOS on the module and wait for the command line If no error messages appeared the Reserve BIOS is modified correctly Note fwflash exe is a software utility operating under MS DOS or FDOS only fwflash_win exe is run only from the command line of Windows XP CPC304 User Manual 2011 Fastwel v 003a 71 E Basic Software Fastwel Ley CPC304 gt E E Important If an error message appears during or after the BIOS upgrade run fwflash exe or fwflash_win exe utility once
38. ain menu without changing anything 5 9 4 Write to CMOS and Exit After making your changes on the BIOS Setup menus always select Write to CMOS and Exit to store the selections displayed in the menus in CMOS short for battery backed CMOS RAM a special section of nonvolatile memory that stays on after you power down your system The next time you boot your computer the BIOS configures your system according to the Setup parameters stored in CMOS memory On selection of this Main menu command the program displays this message Save Changes and Exit Y N If you choose Y the program saves the BIOS Setup parameters to CMOS exits BIOS Setup and reboots the system N returns you to the Main menu without making any changes During boot up General Software BIOS attempts to load and use the values stored in CMOS If system does not boot with those values reboot and press lt Del gt to enter BIOS Setup In Setup you can try to change the parameters that caused the boot failure or get the Factory Default Values CPC304 User Manual 60 2011 Fastwel v 003a E General Software BIOS Fastwel LBs CPC304 5 9 5 Exit without Changing CMOS Use this option to exit Setup without storing in CMOS any changes you may have made The previous parameters remain in effect The program displays this message Y confirms exiting without saving any changes closes Setup and reboots the system N returns you
39. ble 3 28 Interrupt Settings IRQO System timer IRQ1 PS 2 keyboard IRQ2 8259 interrupt IRQ3 COM2 IRQ3 line of external ISA bus PFO Opto IRQ IRQ4 COM1 IRQ4 line of external ISA bus PFO Opto IRQ IRQ5 Ethernet USB Audio PC 104 ISA PC 104 Plus PCI expansion modules PFO Opto IRQ IRQ6 FDD IRQ6 line of external ISA bus PFO Opto IRQ IRQ7 LPT IRQ7 line of external ISA bus PFO Opto IRQ IRQ8 RTC PFO Opto IRQ IRQ9 ACPI IRQ9 line of external ISA bus PFO Opto IRQ IRQ10 Ethernet USB Audio IRQ10 line of external ISA bus PFO Opto IRQ IRQ11 Ethernet USB Audio IRQ11 line of external ISA bus PFO Opto IRQ IRQ12 PS 2 mouse IRQ12 line of external ISA bus PFO Opto IRQ IRQ13 Reserved for math coprocessor IRQ14 HDD CompactFlash NAND flash PFO Opto IRQ IRQ15 COM3 COM4 PFO Opto IRQ 3 3 4 DMA Channels By default DMA channels are assigned for use by internal units of the module Channel 1 is used by LPT port channel 2 by FDD controller A DDMA controller of IT8888G PCI ISA bridge is used to provide access to DMA channels for external PC 104 devices DDMA controller programming is described in Subsection 5 10 6 of this document CPC304 User Manual 44 2011 Fastwel v 003a E Functional Description Fastwel EN CPC304 3 4 Overall and Mounting Dimensions Figure 3 16 CPC304 Overall and Mounting Dimensions
40. c All rights reserved gt Basic CMOS Configuration Features Configuration Custom Configuration CPC304 Specific Configuration PNE Contiguration Shadow Configuration Start R9232 Manufacturing Link Reset CMOS to last known values Reset CMOS to factory defaults Write to CMOS and Exit Exit without changing CMOS lt Tab gt to select lt Esc gt tOo Continue no save www gensw com www fastwel ru The Main Menu items and their functions are described in the table below Table 5 1 Main Menu Items Menu Item Purpose Basic CMOS Configuration This item lead you to the menu which allows you to setup the main system parameters such as System date and time Disk drives types definition and letter assignments Boot sequence and others Features Configuration This item allows to set such system features as Ultra DMA mode ACPI support and boot options Custom Configuration This item opens a menu screen where you can setup interrupt levels of PCI and ISA devices select console I O devices set video memory size LCD panel parameters CPU frequency etc CPC304 Specific Configuration The item specific for CPC304 COM3 and COM4 ports setup PnP Configuration This menu item gives you access to Plug and Play related IRQ and DMA settings Shadow Configuration Shadow memory configuration item allows you to select BIOS extensions memory blocks to copy into RAM on module initialization Start RS232 Manufacturing Li
41. charge can be sufficient to destroy or degrade a component s operation Therefore all handling operations and inspections of this product must be performed with due care in order to keep product integrity and operability a Preferably unpack or pack this product only at EOS ESD safe workplaces Otherwise it is important to be electrically discharged before touching the product This can be done by touching a metal part of your system case with your hand or tool It is particularly important to observe anti static precautions when setting jumpers or replacing components 5 If the product contains batteries for RTC or memory back up ensure that the module is not placed on conductive surfaces including anti static mats or sponges This can cause short circuit and result in damage to the battery and other components a Store this product in its protective packaging while it is not used for operational purposes Unpacking The product is carefully packed in an antistatic bag and in a carton box to protect it against possible damage and harmful influence during shipping Unpack the product indoors only at a temperature not less than 15 C and relative humidity not more than 70 Please note that if the product was exposed to the temperatures below 0 C for a long time it is necessary to keep it at normal conditions for at least 24 hours before unpacking Do not keep the product close to a heat source Following ESD precautions carefully take th
42. cking Inspection and Handling 7 Three Year Wamramty nn nn nn nn Un nner eine eee eee nnnaaeeeeee enna 8 1 ite Dee E 9 1 1 Medglelntrogdt etioft inniinn aia iin en avin eee eee eee 9 1 2 e EE Le channel obese adaddand oaadaaddsdadaaneadand 10 1 3 Delivery e TE E 11 1 4 Additional ACcessorles ti anaana ARAA AAAA AAAA AAA AAAA AARAA EANA AARAA ARAARA RANA AAAA RAKARE 11 1 5 Supplementary Information 12 1 5 1 Related Documents 12 2 Technical Specifications cccccccccceeeseeee ee ee ee eeeeeeeceeeee eee eeeeeeecaeeeeeeeeegaaeeccaeeeeseeegaaaeeceeeeeeeeeeaneeseneees 13 2 1 ET 13 2 2 Power Heoutrements AAA 15 23 Environmental vec sine iae a EE laateng es Hearn ceed gedd ath eadde cet daadnesbes EES een easton 15 el e EE 15 2 5 Dimensions and Weoht itr nr nn nn nn eee aee tees ee tnncieeeeeeee enna 15 2 6 MIBFisstusackoghvudadupnbadshanbadatash ee Ee EEN eg 15 3 Functional Description cceseeee eee e teen eee e eee e eee eeeee eee eae eee eee neeaeeeee eee 16 3 1 Structure ANG Layouten ienaa Ea AE a EEEa EAA AEE EEAS AAAA EaR EA 16 32 Functional Descriptio iaeei oee tae n Eae aa DEE ane is aar a oa aeuo Sst e AE 19 3 2 1 Microprocessor EEN 19 3 2 2 SDRAM Memor 19 3 2 3 Reserved Flash BIOS eepesgzgtes e zgtegk ctedeaeetietecheaietacs a ate tiated geg Eege Ee 19 3 2 4 IDE Men ees eebe es ccc ee ee 20 3 2 4 1 Connection of External IDE Devices cc eeecteeeeree eee eeeriieeeeeeeeteenaeeeeeeeetneea 20 3 2 4
43. commended see details in Power Supply section of this document The following devices may be connected to the module to serve as a display unit Monitor of a remote PC console operation connected via DB9F IDC10 adapter cable to J14 connector or via a null modem cable to COM1 connector of KIB380 SVGA monitor directly connected to VGA connector of KIB380 interface expansion module or to CPC304 J18 connector via adapter TFT DSTN panel connected to J17 connector of CPC304 P Y cable allowing to connect a mouse and a keyboard to the module s J7 connector These two devices can also be connected directly to PS 2 connectors of KIB380 expansion module The operating system is loaded from the on board NAND Flash memory Operating system on this flash disk is FDOS supplemented with some service software utilities The lithium battery assembly supplied with CPC304 may be installed in a holder on the CPU heatsink to power the RTC and CMOS memory for storage of BIOS Setup parameters However the module can operate without the battery thanks to the fact that system configuration parameters except the current time and date settings are stored in serial FRAM The figure below shows how cables a null modem cable and ACS00023 adapter cable are connected for console operation via COM1 J14 or COM2 J15 ports of CPC304 The number of the serial port for console operation is assigned in BIOS Setup To connect to a remote PC using KIB380
44. d settings in Basic CMOS Configuration section of BIOS Setup CPC304 User Manual 29 2011 Fastwel y 003a E Functional Description Fastwel Ley CPC304 3 2 5 Video Controller and Connection of Monitors The module utilizes graphics controller integrated in Geode LX CPU with the following main features Video memory size up to 60 MB shared with system It is recommended to use 32 MB as set by default in Custom Configuration section of BIOS Setup Supported resolution up to 1024x768 60 Hz for TFT or DSTN LCD panels at 18 bpp for LVDS CPC30401 and 03 only panels at 24 bpp only Support of VGA CRT monitors with resolution up to 1600x1200 85 Hz or 1920x1440 75 Hz 32 bit color CRT display and LCD panel simultaneous operation TFT LCD panels with color depth of 9 12 or 18 bits are connected directly to J17 header IDC30 1 27 mm pitch AMP 1 111196 9 counterpart of CPC304 using custom interface cable The following table presents its pinout Table 3 4 TFT J17 Header Pinout 1 GND 16 DRGB13 G3 2 DOT_CLK 17 DRGB14 G4 3 HSYNC 18 DRGB15 G5 4 VSYNC 19 GND 5 GND 20 DRGB2 BO 6 DRGB18 RO 21 DRGB3 B1 7 DRGB19 R1 22 DRGB4 B2 8 DRGB20 R2 23 DRGB5 B3 9 DRGB21 R3 24 DRGB6 B4 10 DRGB22 R4 25 DRGB7 B5 11 DRGB23 R5 26 GND 12 GND 27 DISPEN 13 DRGB10 G0 28 3 3V 14 DRGB11 G1 29 3 3V 15 DRGB12 G2 30 GND
45. ddress Current address A31 A24 4 Word counter D7 D0 5 Word counter D15 D8 6 Word counter D23 D16 Possibility to use the upper byte of an address and a counter is set by a bit in configuration register for each channel 8237 controller has 16 bit data registers so to access them two consecutive input output operations are needed First operation moves the lower byte of the value Though DDMA controller allows to access each byte in these registers at separate addresses there is still possibility to write in Legacy DMA style The high low switch is reset to initial state by writing to register with OCh offset like in 8237 although the ITE documentation states that write operation is ignored Like in 8237 the switch affects all channels of the controller and changes its value both on writing to or on reading from the register Thus reading the register right after writing to it returns the next byte but not the written value DDMA control registers addressing in IT8888G is similar to the one of 8237 but some registers are not used Also there are some differencies in interpreting bit fields due to DMA channels sharing CPC304 User Manual 65 2011 Fastwel v 003a E General Software BIOS Fastwel LBs CPC304 Attention A The command register offset 8 allows to change the controller settings although the ITE documentation states that the value necessary for normal operation is hardware fixed In this c
46. e power is switched off For extra safety the system settings are stored also in the nonvolatile serial FRAM 5 2 Main Menu To start the BIOS Setup program switch on the power or restart the system By default the startup screen looks like this General Software Embedded BIOS R 2000 Revision 5 3 Copyright C 2005 General Software Inc All rights reserved Fastwel adaptation for board CPC304 Revision 2 4 0 C 2006 2009 Fastwel Co Ltd if you want to run SETUP Low Memory 00228352K Ext Memory PCI Device Table Bus Dev Func VendID DevID Class 00 O1 00 1022 2080 Host Bridge 00 O1 OI 1022 2081 VGA Display 00 O01 02 1022 2082 Unknown Device 00 OC 00 1283 8888 PCI Bridge 00 OD 00 8086 1209 Ethernet DU OE OO 8086 1209 Ethernet 00 OF OO 1022 2090 ISA Bridge DU OF 0 1022 209A IDE Controller 00 OF 03 1022 2093 Audio 04 1022 2094 Serial Bus 2095 Serial Bus 500 MHz emory Frequency 333 MHz Node ID Fn ORO ROROLOROROLON G1 CNS CPC304 User Manual 50 2011 Fastwel v 003a E General Software BIOS CPC304 To start BIOS Setup press Del key on a keyboard after the message Hit lt Del gt if you want to run SETUP appeared on the screen This will lead you to the Main Menu screen shown in the Figure below Attention In remote console mode the BIOS Setup utility is started by using ctrl c combination on the keyboard of a remote PC Figure 5 1 Main Menu Screen Image C 2005 General Software In
47. e eecaaeeeeeeeteecnaeeeeeeeeeneeaaeeeeeeess 31 JZ CONTACTS DESI GMAL OM EE 31 Audio J9 and J8 in 32 J25 Jumpers POSION Seii iaaiaee Eegenen 33 J26 Jumper POSITIONS 2 sgean naene iin aN EN EA A EAA EAE AAEE EENE na 34 J28 Jumpers Position 34 J5 GOMtACTS DESI QMALIOM ET 35 JPME Connector PINOUT seis deeg a cto de senvednssdacndeeeeatwensanketeeebarevaas eee aes 35 J3 Battery Connector PINOUT 2 eu82eEee AER EES NEEN ENEE SEENEN 36 CPC304 Diagnostic LEDS FUNCTION eect nn i eee e ee aaee tree ee tnnaaeeeeeeee need 36 J30 External LEDS Connector ccccccccceceeeeeeeee eee eee eeeeeeeeeaeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 37 ISA P J1 Connector Rows A and B Contacts Desigonation 38 ISA P J1 Rows C and D Contacts Desionaton 39 PCI P J2 Connector Contacts Designation cccceeeceeeeeeeeecneee eee e rete eenaaeeeeeeeeteeniaaeeeeeeeeteenaaeees 40 J24 Power Connector PinOUtis i icsteiecaactelanitisiveiciesientilicehedasdierd eldteia vii odin ENEE SEKR 41 Memory Address Mapping iinet i inn eee anne eter nnn aaeeeeeeeetnenaaeeeeeeeenennaaeees 42 VO Address SPaCe EEEE 43 Interrupt Settings nr nn nnn eee anee ieee ee ninaeeeeeeeeneenaaeees 44 Maini Menu temis E 51 Basic CMOS Configuration Menu Wems eect er een tine eee e rete neeeeeeeeeeenaaeeeeeereneeniaaeees 53 Features Configuration Menu Items cece cient errr eet tiee eee e rete aaeeeeeeeetneniaeeeeeeeenenniaaeees 54 Custom Configuratio
48. e product out of the shipping carton box Proper handling of the product is critical to ensure correct operation and long term reliability When unpacking the product and whenever handling it thereafter be sure to hold the module preferably by the front panel card edges or ejector handles Avoid touching the components and connectors Retain all original packaging at least until the warranty period is over You may need it for shipments or for storage of the product Initial Inspection Although the product is carefully packaged it is still possible that shipping damages may occur Careful inspection of the shipping carton can reveal evidence of damage or rough handling Should you notice that the package is damaged please notify the shipping service and the manufacturer as soon as possible Retain the damaged packing material for inspection After unpacking the product you should inspect it for visible damage that could have occurred during shipping or unpacking If damage is observed usually in the form of bent component leads or loose socketed components contact Fastwel s official distributor from which you have purchased the product for additional instructions Depending on the severity of the damage the product may even need to be returned to the factory for repair DO NOT apply power to the product if it has visible damage Doing so may cause further possibly irreparable damage as well as result in a fire or electric shock hazard
49. e selection IDE controller default IRQ15 COM3 COM4 OPTO IRQ IRQ15 interrupt source selection COM3 COM4 ports default Reserved for optoisolated Reset input Remember Wrong or incorrect settings may lead to abnormal system performance To correct possible errors restart the BIOS Setup program and restore manufacturer s settings by selection of Reset CMOS to factory defaults command in the Main menu CPC304 User Manual 2011 Fastwel 57 CPC304 v 003a E General Software BIOS CPC304 5 6 CPC304 Specific Configuration This BIOS Setup section contains only one item RS485 Default allowing to set data transfer direction for COM3 and COM4 RS485 422 ports enabled at startup Table 5 5 CPC304 Specific Configuration Menu Item Menu Item Options Description RS485 Default Transmit Default setting Transmitters of COM3 and COM4 ports are enabled at startup this is used for full duplex connection or for operation in RS422 mode Receive This setting disables transmitters of COM3 and COM4 ports the ports are set to receive data at startup This is used for half duplex connection to the RS485 multiuser network 5 7 PnP Configuration This BIOS Setup section provides access to Plug and Play related IRQ and DMA assignments The menu screen is shown in the figure below Figure 5 5 Plug n Play Configuration Menu Screen Image System BIOS Setup Plug n Pla
50. eatnici dai ei dat eae ee el 41 3 3 Address Mappipng u ienei egene eene denge aaa a a aaa ai akasi 42 3 3 1 Memory Addressing eisen iia iiaa aN AEAN E ATENEA EA A Nai REEERE ENEE 42 3 3 2 egene EE 43 3 3 3 elle CLINGS EE 44 3 3 4 DMA Channel 44 3 4 Overall and Mounting Dimensions eee nr nn i eee nee eee eee tnnnaeeeeeeeenneea 45 4 External Connections geess eeEeegeeeee 46 4 1 Safety Regulation S EE 46 4 2 Connection of Peripheral Devices AAA 47 4 2 1 CompactFlash Cards Installation ieee ine te i naan tees een aaeeeeeeeennenaeeeeeeeetneea 49 4 2 2 USB Devices Connection 0 eee i nit rr ieee aaeeeee eee tinnaeeeeeeeetneciaaeees 49 4 2 3 Battery Hepnlzcement cece ee i nn tr i i nn tr inner eter aaeeeeeeeetnencaeeeeeeeetneniaaeees 49 43 SOttWareIMStall AtlON ET 49 5 General Software BIOS 0 ccccccceeeeeeseeee seen eee eeeeaeee seen eee eeeaaeeeeaeeeeeeeegggeecaeeeeaaeeeeaaeeceeeeeeaeeeeeaeeeennees 50 bi BIOS Setup Program Introducnon s i siieme riisin naniii pan keikan eiea ieni in etai aa eetan niine 50 52 Main Men esis ca esixleksecncaeceeapesuneatsaa les EE RE eg Eed egen AAEE EES 50 5 3 Basic CMOS Configuration cee rn nn nn nn nn eee aee reesei tnnnaeeeeeeeetneea 52 5 4 Features Configuration eee ee nn nn ee eee eee eee een aaeeeeeee renee 54 5 5 Custom Be elle le EE 55 5 6 CPC304 ee ue E LIT 58 57 PAP GONPQUIATION EE 58 5 8 Shadow Configuration EE 59 5 9 The Rest Main Menu Comma
51. ed to power the RTC and CMOS memory where BIOS Setup parameters are stored while the power is off However the module can be operated without the battery see subsection 3 2 15 for details Table 3 19 J3 Battery Connector Pinout 1 3V 2 GND Note xX It is recommended to disconnect the battery from J3 connector if the module is not operated for a long time 3 2 21 Diagnostic LEDs CPC304 has seven diagnostic LEDs D1 D6 D11 D12 D20 D26 D27 Figure 3 2 on the top side of the module If the processor module is installed into the mounting cage additional light pipes can be provided to conduct the light to the front panel The following table describes the function of these LEDs Table 3 20 CPC304 Diagnostic LEDs Function D11 Green User LED1 D12 Green User LED2 D27 Yellow Processor reset by WDT This LED lights up when the processor had been reset on WDT timeout expiry It is not lit during normal operation D20 Orange IDE activity D1 Green Ethernet controller 1 activity D6 Green Ethernet controller 2 activity D26 Green Yellow Power mode green operation yellow sleep User LEDs are controlled via the Super IO GPIO port lines LED1 via GPIO23 and LED2 via GPIO35 1 LED is off 0 LED is on See also subsection 5 9 4 for details On the module version 1 3 and higher there is an additional connector J30 enabling operation with external diagnostic LEDs It is 8 p
52. ees External LEDS Conneccion gegen ageet Baie ds a ee A es ae ee anaes ISA Header Contacts Layout s icccoc eta ctis sats aana Gloeatiaadun adds lea Ee E EE PCI P J2 Connector Contacts Layout J24 Power Supply Conpector seer ee eeecaaaeeeeeeeeeecaaeeeeeseeteennaaeeeeees CPC304 Overall and Mounting Dimensions eect teeter eter eee ee iaaeeeeee ee neneaeeeeeeee ence External Devices Connection 0 cece er nn ee ieee r ee eee aaeeeeee ee neenaaeeeeeeeeneenaaeees Cables Connection for Console Operation m Main Menu Screen Image 2 ekeNEieeENEEdEKdEE ENEE Basic CMOS Configuration Screen Image Features Configuration Menu Screen Custom Configuration Menu Green Plug n Play Configuration Menu Screen Image seessseesesssessseirrrsssertirrtttssetttrrnttasttttnnnnnnsetennnnnnne Shadow Configuration Menu Screen Image All information in this document is provided for reference only with no warranty of its suitability for any specific purpose This information has been thoroughly checked and is believed to be entirely reliable and consistent with the product that it describes However Fastwel accepts no responsibility for inaccuracies omissions or their consequences as well as liability arising from the use or application of any product or example described in this document Fastwel Co Ltd reserves the right to change modify and improve this document or the products described in it at Fastwel s discretion with
53. em modification Solid State Disk except for CPC30402 Soldered 1 GB NAND flash o IDE interface MS DOS compatible Fastwel file system CompactFlash socket Type Hl cards support bottom side DMA mode support Video controller 2D accelerator Video memory up to 60 MB shared with system LCD TFT or DSTN panels support resolution up to 1024x768 at 60 Hz 18 bit color via TFT interface 24 bit color via LVDS interface except for CPC30402 Analog display support resolution 1600x1200 at 85 Hz 1920x1440 at 75 Hz 32 bit Ethernet Two Fast Ethernet ports 10 100 Mbit s for CPC30402 one channel USB E Two USB 2 0 channels One device can be connected to each channel CPC304 User Manual 13 2011 Fastwel v 003a E Technical Specifications Fastwel Ley CPC304 E IDE port 5 One IDE channel Primary 8 Support for up to two UltraDMA 100 IDE devices via a 10 cm cable with NAND Flash disabled in BIOS Setup and if the CompactFlash socket J20 is not populated E FDD Floppy disk interface Header shared with LPT a Parallel port E SPP ECP EPP compatible Header shared with FDD controller Serial ports Four serial ports three for CPC30402 High speed NS16C550 compatible a COM1 COM2 RS232 9 wires complete up to 115 2 Kb s console operation support COM3 COM4 RS422 485 500V isolation up to 115 2 Kb s FIFO buffer for each channel 64 bytes for CPC30402 COM3 only E PS 2
54. erved BIOS in system modification 2x512 KB Onboard NAND flash disk 1 GB CPC30401 and 03 only CompactFlash socket J20 Integrated graphics controller Video memory up to 60 MB shared with system LCD TFT or DSTN panels support resolution up to 1024x768 J17 z Analog RGB display support J18 E LVDS interface J16 CPC30401 and 03 only Two Fast Ethernet channels 10 100 Mbit s J4 CPC30402 has one channel Two USB 2 0 channels J21 IDE port with support for up to two UltraDMA 100 devices J19 FDD LPT shared header J23 Serial ports COM1 J14 COM2 J15 RS232 COM J11 COM J13 CPC30401 and 03 only RS422 RS485 PS 2 keyboard mouse port J7 Audio port J8 J9 Optoisolated remote Reset interrupt input J27 Real time clock with Li battery backup CMOS SFRAM for BIOS configuration storage Two watchdog timers Eight digital I O lines J5 External PME signal connector J6 Lithium battery connector J3 PC 104 ISA and PC 104 Plus PCI expansion connectors External power connector J24 Layouts of main CPC304 components and connectors on top and bottom sides are presented in Figures 3 2 and 3 3 respectively Some external devices can be connected to the module using KIB380 interface expansion module KIB380 is equipped with standard connectors giving access to audio port two RS232 and two RS422 485 ports VGA LPT PS 2 keyboard and mouse two Ethernet ports and two USB ports
55. escription Fastwel Lee CPC304 3 2 4 2 CompactFlash Socket CompactFlash Type I II cards can be connected to J20 socket on the bottom side of CPC304 The device in this socket shares Primary channel with other IDE devices When CompactFlash socket is populated only one more IDE device can be connected to CPC304 CompactFlash device can operate as Master or Slave see J26 jumper positions description and can be designated as bootable device The pinout of the J20 socket is presented in the following table Table 3 3 J20 CompactFlash Socket Pinout 1 GND 26 CD1 2 D03 27 D11 3 D04 28 D12 4 D05 29 D13 5 D06 30 D14 6 D07 31 D15 7 CSO 32 CS1 8 A10 NC 33 WEN 9 ATA SEL 34 JORD 10 A09 NC 35 IOWR 11 A08 NC 36 IWE 12 A07 NC 37 INTRQ 13 VCC 5V 38 VCC 5V 14 A06 NC 39 CSEL 15 A05 NC 40 INS2 16 A04 NC 41 RESET 17 A03 NC 42 IORDY 18 A02 43 INPACK 19 A01 44 REG 20 A00 45 DASP 21 D00 46 PDIAG 22 DO 47 D08 23 D02 48 D09 24 IOCS16 49 D10 25 CD2 50 GND Note NC indicates that this contact is not connected to the module s circuits Note A If the module is operated in harsh environment with high vibration load it is necessary to make additional arrangements to fix the CompactFlash card in the socket CPC304 User Manual 21 2011 Fastwel v 003a E Functional Description Fastwel L CPC304 3
56. harge Fastwel neither assumes nor authorizes any other liability in connection with the sale installation or use of its products Fastwel shall have no liability for direct or consequential damages of any kind arising out of sale delay in delivery installation or use of its products H a product should fail through Fastwel s fault during the warranty period it will be repaired free of charge For out of warranty repairs the customer will be invoiced for repair charges at current standard labor and materials rates Warranty period for Fastwel products is 36 months since the date of purchase The warranty set forth above does not extend to and shall not apply to 1 Products including software which have been repaired or altered by other than Fastwel personnel unless Buyer has properly altered or repaired the products in accordance with procedures previously approved in writing by Fastwel 2 Products which have been subject to power supply reversal misuse neglect accident or improper installation Returning a product for repair 1 Apply to Fastwel company or to any of the Fastwel s official representatives for the Product Return Authorization 2 Attach a failure inspection report with a product to be returned in the form accepted by customer with a description of the failure circumstances and symptoms 3 Carefully package the product in the antistatic bag in which the product had been supplied Failure to package in antista
57. ications that use COM3 and COM4 ports remember that these ports use 03E8h and 02E8h addresses respectively and IRQ15 interrupt CPC304 User Manual 64 2011 Fastwel v 003a E General Software BIOS Fastwel LBs CPC304 5 10 6 Programming of DDMA Controller of IT8888G Bridge IT8888G PCI to ISA bridge integrates two four channel DMA controllers 8237 to provide 7 independent DMA channels since channel 4 is used for cascading Each channel has its own base address and can be enabled or disabled separately When programming DDMA in certain cases it is implied that commands relate to 4 channel group like in 8237 controller The DDMA channels 0 3 are fixed at 8 bit transfer width and channels 5 7 are fixed at 16 bit transfer width Channels 0 3 are function of the first controller channels 5 7 are function of the second controller In CPC304 only 5 DDMA channels are available 0 1 3 5 7 On initialization for each DDMA channel a base address is assigned Table 5 6 CPC304 DDMA Channels Base Addresses SS ES 0 2000h 1 2100h 3 2300h 5 2500h 7 2700h Each channel has 16 registers 8 data registers A3 0 and 8 control registers A3 1 The following table describes the data registers of the DDMA controller Table 5 7 DDMA Controller Data Registers 0 Base address Current address A7 A0 1 Base address Current address A15 A8 2 Base address Current address A23 A16 3 Base a
58. imes 00 S 22 3 29 First Boot From C Fl Error Wait Enabled NumLock Disabled Typematic Rate S000 eps Typematic Delay O25 Ss USB Hard Drive s Onboard Flash Disk lst Disk Disk C Floppy Disk Drive Disabled Enabled IDE Master Not installed Memory Base Ee ETS 1 lt CR gt lt Tab gt to select or lt PgUp gt lt PgDn gt to modify lt Esc gt to return to main Menu The figure shows the default parameters Use arrow keys lt Tab gt key and lt Enter gt to move between items and for selection lt PgUp gt lt PgDn gt lt gt or lt gt are used to change the selected parameter lt Space gt in console operation lt Esc gt to return to the Main Menu The following table presents explanations on Basic CMOS Configuration menu screen CPC304 User Manual 52 2011 Fastwel v 003a E General Software BIOS Fastwel Len CPC304 Table 5 2 Basic CMOS Configuration Menu Items Date Time These items allow you to set system date and time Date format Mmm DD YYYY time format hh mm ss First Boot From Selection of disk name to boot from first Choice set A C CDROM F1 Error Wait Enables or disables waiting for pressing of lt F1 gt key on POST error enabled by default NumLock Allows to control the numeric keypad state after boot Enabled NumLock On Disabled NumLock Off default Typematic Rate Keyboard autorepeat
59. in one row connector on the bottom side of the module Recommended counterpart for making a custom cable is Leotronics 2018 3081 socket with Leotronics 2023 contacts CPC304 User Manual 36 2011 Fastwel v 003a E Functional Description Fastwel Lee CPC304 Table 3 21 J30 External LEDs Connector 1 HDD_LED IDE activity external LED cathode 2 WDT_LED Watchdog timer timeout expiry external LED cathode 3 GND Ground of the module 4 VCC 3 3 V 5 LAN1 LAN1 Ethernet controller activity external LED anode 6 LAN1 LAN1 Ethernet controller activity external LED cathode 7 LAN2 LAN2 Ethernet controller activity external LED anode 8 LAN2 LAN2 Ethernet controller activity external LED cathode Figure 3 12 External LEDs Connection 3 2 22 Reset Button Signal Pin HDD_LED WDT_LED GND VCC WDT LAN1 LAN1 LAN2 LAN2 INID co Po 7 LANI Ze LAN2 In the event of a contingency module hang up for example use the Reset button SW1 on the top side of the module to reset the system CPC304 User Manual 37 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 3 2 23 Expansion Buses ISA and PCI The module is equipped with two interface expansion headers stipulated by PC 104 Plus specification 104 pin ISA and 120 pin PCI connector
60. interface module only the null modem cable is needed Figure 4 2 Cables Connection for Console Operation PC COM port CPC304Connec ford14 DB9 IDC10 D OO JO Null ModemCable The HyperTerminal program running on the PC to support console operation should have the following settings Transfer rate 115200 bit s Data bits 8 Stop bits 1 Parity check Off CPC304 User Manual 48 2011 Fastwel v 003a E External Connections Fastwel Een CPC304 4 2 1 CompactFlash Cards Installation CompactFlash socket of CPC304 J20 supports 5 V CompactFlash ATA type I II cards Carefully slide in the correctly oriented card and gently press to engage the contacts completely Note XK Connection of the CompactFlash cards while the power is on may damage your system CompactFlash socket description can be found in subsection 3 2 5 4 2 2 USB Devices Connection CPC304 can accept Plug amp Play connection of USB 2 0 computer peripheral devices printers keyboards mice etc All USB devices may be connected or disconnected while the host power is on Direct USB devices connection is possible via KIB380 interface expansion module 4 2 3 Battery Replacement The lithium battery assembly must be replaced with the battery assembly 469539 012 supplied by Fastwel The expected life of a 190 mAh battery is about 5 years However this typical value may vary because battery life depends on the operating temperature and the sh
61. ional Accessories Peripheral devices are attached to the module directly or via additional accessories and cables listed in the following table Additional accessories are not supplied with the CPU module are ordered separately Table 1 3 CPC304 Additional Accessories KIB380 469515 004 Interface expansion module with standard connectors and cable set ACS00027 685611 123 Adapter cable IDC10 2 mm DHS 15F for connection of VGA monitor to the module ACS00031 01 467941 016 PHR 5 connector set Includes JST PHR 5 socket and a set of contacts SPH 002T P0 5S for connection to J9 J11 or J13 headers of the module ACS00031 02 467941 016 01 PHR 6 connector set Includes JST PHR 6 socket and a set of contacts SPH 002T P0 5S for connection to J7 header of the module ACS00031 03 467941 016 02 PHR 2 connector set Includes JST PHR 2 socket and a set of contacts SPH 002T P0 5S for connection to J6 or J8 headers of the module ACS00037 DF13 connector set Includes Hirose DF13 20DS 1 25C socket and a set of contacts DF13 2630SCF for connection to J16 header ACS00038 Connector set for connection of a power supply unit to the module Includes AMP 4 171822 4 socket and a set of contacts 170263 1 for connection to J24 power connector of the module ACS00040 01 IDC 10 connector set Includes Leotronics 2040 3102 socket for connection to J14 J15 J18 or J21 headers of the module ACS00040 02
62. itched for use by ISA bus devices in BIOS Setup program A floppy disk drive or printer are connected to J23 header of CPC304 via custom cable The recommended counterpart connector for J23 is Leotronics 2040 3262 see ACS00040 03 accessory The table below describes pin assignments of J23 connector Table 3 9 LPT FDD J23 Connector Pinout 1 STB 2 AFD DRVDEN 3 PDO INDEX 4 ERROR HEAD CPC304 User Manual 27 2011 Fastwel v 003a E Functional Description Fastwel L CPC304 5 PD1 TRACK 6 INIT DIR 7 PD2 WP 8 SLCTIN STEP 9 PD3 RDATA 10 GND GND 11 PD4 DSKCHG 12 GND GND 13 PD5 14 GND GND 15 PD6 MOA 16 GND GND 17 PD7 DSA 18 GND GND 19 ACK DSB 20 GND GND 21 BUSY MOB 22 GND GND 23 PE AND 24 GND GND 25 SLCT ANE 26 5V 5V A printer can also be connected to DB25F connector J21 at KIB380 interface expansion module The connection between J23 at CPC304 and J20 at KIB380 is made with one of the interface cables supplied with KIB380 see the connections diagram in Chapter 4 3 2 9 Serial Ports The CPC304 01 and 03 are furnished with four serial ports CPC304 02 with three 3 2 9 1 COM1 and COM2 RS232 Figure 3 7 IDC10 Pins Numbering i COM1 and COM2 ports have standard PC AT base addresses S sdf They are routed to J14 and J15 IDC10 connectors 2 mm pitch ee respectively a
63. l mask register Single Mask DMA MODE EQU OOBh Mode register DMA_FF EQU 00Ch High low switch register Let s take DMA 2 channel floppy disk drive as a sample DMA2ADR EQU 04h DMA 2 channel current address register DMA2CNT EQU O5h DMA 2 channel counter register DMAPG2 EQU 81h DMA 2 page register DMARST EQU 00h Mask or request reset command DMACH2 EQU 02h Channel bits for reset command CPC304 User Manual 66 2011 Fastwel v 003a E General Software BIOS Fastwel Ley CPC304 Legacy DMA controller programming for reading from FDD data preparation and other transformations omitted mov AL 46h mov DX DMA MOD out DX AL Gl r E DMA reading mode DMA controller mode register Set counter for bytes read from AX mov DX DMA_FF out DX AL TODELAY mov DX DMA2CNT out DX AL TODELAY xchg AL AH out DX AL TODELAY r r T r Set 0 23 address bits mov DX DMA2ADR mov AL BL out DX AL TODELAY mov AL BH out DX AL TODELAY mov AL CL mov DX DMAPG2 out DX AL TODELAY Enable DMA request for mov DX DMA_MASK mov AL DMARST DMACH out DX AL 2 T High low switch register Clear high low switch Delay for bus recovery DMA 2 channel counter register Set lower byte of the counter Delay for bus recovery Higher byte of the counter to AL Set the higher byte of the counter Delay for bu
64. le is equipped with a standard Real Time Clock The supplied with CPC304 3 V lithium battery assembly is installed in a holder on the processor heatsink Being connected to J3 power connector 1 3V 2 GND it is used to power the RTC and CMOS memory when the system power is off FRAM is non volatile memory with DC serial interface It serves as a back up storage for BIOS Setup parameters and for restoration of the RTC memory except the time and date settings if an error is detected This feature enables the possibility to operate the module even when the battery is disconnected Free FRAM memory units 7 KB are available to the user via INT17H BIOS extensions see subsection 5 9 3 for details For long term storage of the CPC304 module disconnect RTC battery by disengaging power cable from J3 connector In case of operating system crash and if BIOS Setup program can not be started BIOS settings can be reset using CMOS_RST COM program It is started under FDOS 6 22 on a remote PC connected to CPC304 module with a null modem cable via COM1 port After this procedure BIOS settings are reset to default ones on module s power up see section 6 2 for details of the procedure 3 2 14 Watchdog Timers CPC304 has two watchdog timers WDT1 is integrated in ADM706T supervisor chip and has fixed timeout period of 1 6 s After power up and POST WDT1 is disabled WDT1 is controlled via INT 17h BIOS extensions and by setting the SuperlO W83627HG
65. m 40 C to 85 C Storage temperature 55 C to 90 C Relative humidity up to 80 at 25 C noncondensing Note Protective coating of CPC304 versions makes them resistant to damp heat cyclic exposure at temperatures up to 55 2 C and relative humidity of up to 93 3 2 4 Mechanical E Vibration 10g E Single shock peak acceleration 150 g E Multiple shock peak acceleration 50 g 2 5 Dimensions and Weight E Dimensions not more 115 6 x 101 5 x 23 7 mm 4 55 x 4 x 0 93 see also section 4 4 for mounting dimensions E Weight not more 0 2 kg without CompactFlash card 2 6 MTBF m MTBF for CPC304 is 170000 hours The value is calculated according to Telcordia Issue 1 model Method I Case 3 for continuous operation at a surface location at normal environmental conditions and at ambient temperature 30 C CPC304 User Manual 15 2011 Fastwel v 003a E Fastwel Lee
66. miting circuits Maximum output current is 20 mA per channel The channels have outputs imitating open collector Samples of Winbond W83627HG Super IO GPIO programming can be found in W83627 pdf file on the documentation CD The following table shows J5 contacts designation Table 3 17 J5 Contacts Designation 1 GPIO10 DISCIO_0O 2 GPIO11 DISCIO_1 3 GPIO12 DISCIO_2 4 GPIO13 DISCIO_3 5 GPIO14 DISCIO_4 6 GPIO15 DISCIO_5 T GPIO16 DISCIO_6 8 GPIO17 DISCIO_7 9 GND For custom cables the AMP 1 87499 5 socket with contacts 167021 2 are recommended see ACS00041 accessory 3 2 19 External PME Signal Connector An external PME signal source can be connected to the module via the 2 contact 2 mm pitch JST header J6 The system can be woken up by the PME signal Table 3 18 J6 PME Connector Pinout 1 PME 2 GND For making a custom cable it is recommended to use JST PHR 2 counterpart socket with JST SPH 002T P0 5S contacts for crimping ACS00031 03 accessory CPC304 User Manual 35 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 3 2 20 Battery Connector The module is equipped with the 2 contact 2 mm pitch JST header J3 for connection of the supplied with the module 3V lithium battery assembly 469539 012 The battery assembly is inserted in the plastic holder mounted see section 4 2 3 on the processor heatsink next to J3 connector The battery is us
67. more than 4 W are used it is not allowed to power the stack via J24 connector In this case the stack must be powered via PC 104 connector CPC304 User Manual 41 2011 Fastwel v 003a E Functional Description Fastwel LE CPC304 SE E Important For stable operation of the module without external devices it is recommended to use a power supply unit with maximum current not less than 3 A When operating the module with a HDD consider using a power supply unit with maximum current not less than 4 A Important After switching power off do not switch it back on in less than 5 seconds Important 5V voltage build up time of a power supply unit must be less than 10 ms The supplied 5V voltage is monitored during operation If this voltage is dropped below 4 75V the PFO interrupt is generated provided the jumper is set to position 4 6 on J28 jumper switch The ISA interrupt line corresponding to PFO is set in BIOS Setup utility as described in Section 5 5 of this Manual A Important Assigning IRQ5 IRQ10 or IRQ11 lines for use with PFO signal make sure that these lines are not set for use by PCI or ISA devices and are not assigned to PCI devices using INT A INT B INT C and INT D lines in Custom Configuration section of BIOS Setup 3 3 Address Mapping 3 3 1 Memory Addressing Table 3 26 Memory Address Mapping 00000h 9FFFFh 640 KB System memory A0000h BFFFFh 128 KB Video memo
68. n Menu Items 00 ieee ee ier eee dee eee e eee aaeeee eee nennaeeeeeeeeeniaea 55 CPC304 Specific Configuration Menu em 58 CPC304 DDMA Channels Base Adresses 65 DDMA Controller Data Heglsiers AAA 65 Legacy DMA Page Register Adresses 66 Jumper Settings by Functon ener eee eeaaaeeee eee eenaaeeeeeeeeteennaaaeeeeeees 74 CPC304 User Manual 3 2011 Fastwel v 003a E Fastwel Ley CPC304 List of Figures Figure 1 1 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 Figure 3 10 Figure 3 11 Figure 3 12 Figure 3 13 Figure 3 14 Figure 3 15 Figure 3 16 Figure 4 1 Figure 4 2 Figure 5 1 Figure 5 2 Figure 5 3 Figure 5 4 Figure 5 5 Figure 5 6 CPC304 Module Appearamnce intr er i nn ri i anne reer aeeeeee ee nnnaaeeeeeeeenieea CP C304 BO k Dia Tu Top Side Connectors and Main Components Layout Bottom Side Connectors and Main Components Layout Connection of Sharp LQ104V1DG61 Panel to CPC304 0000 eee eet errr eteeeaaeeeeeeeeteeea Connection of Sharp LQ150X1LW72 Panel to CPC304 d J21 IDC10 Pins Numbering eee cece eeceee cece ee eeeeeaeeeeeeeeeeeeaaeeeeeeeeeeecaaeeeeeeeeseeenaaeeeeeeeeseeeniaaeeeeees IDG10 Pins NUMBERING DEET J10 and J12 Pinpads Point to Point Connection of Two Modules in RS422 Mode Connection of Several Devices in R8485 Mode Discrete Input Optoisolation cece re nn i eee e reer aaee tees ee teinaaeeeeeeeeneenaae
69. nd operate as full function 9 wire RS232 interfaces 1 9 with maximum transfer rate of 115 2 Kb s They are fully compatible with UART16550 Both COM1 and COM2 ports can be used for communication with a remote PC the port number is selected in BIOS Setup COM1 is used for this purpose by default For console operation and file exchange a null modem and ACS00023 685611 082 cables are needed Recommended counterpart connectors type for custom cables is Leotronics 2040 3102 ACS00040 01 accessory CPC304 User Manual 28 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 The following table shows pins designation for J14 and J15 headers Table 3 10 J14 and J15 Pin Assignments 1 DCD 2 DSR 3 RXD 4 RTS 5 TXD 6 CTS 7 DTR 8 RI 9 GND 10 5V When using KIB380 interface expansion module both ports are available via two standard DB9F connectors COM1 J7 and COM2 J3 The connection between J14 and J15 at CPC304 and J6 and J1 at KIB380 are made with the interface cables supplied with KIB380 as shown in the connections diagram in Chapter 4 3 2 9 2 COM3 and COM4 RS485 RS422 COM3 and COM4 ports allow data transmission rates up to 115 2 Kb s and support RS422 RS485 interfaces with 500 V isolation They have standard PC AT base addresses and interrupts RS485 interface operates in echo mode These two ports are routed to J11 and J13 one row 5 pin JST type 2 mm pitch on board connectors
70. nding reset sequence through COM2 press a key to abort 3 Switch on the module The remote PC monitor should display the following message Reset acknowledged BIOS Setup parameters are now reset to factory defaults Now you can start BIOS Setup utility on the module to make necessary settings On a supplied CD v 1 4 and above there is also a utility cmos_rst exe operating under Windows XP This utility is started from the command prompt window The startup parameters are the same as for cmos_rst com CPC304 User Manual 69 2011 Fastwel v 003a E Basic Software Fastwel EN CPC304 6 3 BIOS Upgrade The CPC304 has two Flash BIOS chips with storage capacity of 512 KB each The main working copy of BIOS occupies 512 KB on a chip in PLCC32 panel Reserve BIOS copy is stored on a soldered chip and is used for emergency boot It is possible to upgrade the main and reserve copies of BIOS in system This can be done with the help of fwflash exe or fwflash_win exe utility programs supplied on CD fwflash exe operates on the module under MS DOS or FDOS only To modify the main BIOS copy run this utility with a parameter fwflash exe biosXXX bin where biosXXX bin BIOS binary image file name and wait for Mission complete message To modify the reserve BIOS copy run this utility with an additional parameter reserve fwflash exe biosxXXX bin reserve where biosXXX bin BIOS binary image file name and wait for
71. nds AAA 59 5 9 1 Start RS232 Manufacturing Link eee ne i neers eet aaeee esse eteenaaeeeeeeeeneeea 59 5 9 2 Reset CMOS to Last Known Values 0 0 eee eee etnnnee eter ee teeccaaeeeeeeeeteeeaaeeeeeeeeteeniaaeees 60 5 9 3 Reset CMOS to Factory Detaults ccc ceecieecceeer reer teenie eter eet eecaaeeeeeeeettecaaeeeeeeeeenennaaeees 60 5 9 4 Write to CMOS and EN 60 5 9 5 Exit without Changing CMOS c ieee tne tri ieee rete aaee tees ee tnnncaeeeeeeeennenaaeees 61 5 10 Extended BIOS Functions enn nnn nn nn ee aee nies ee nnnnaeeeeeeee enna 61 5 10 1 ADM706T Supervisor Chip Based Watchdog Timer Control 61 5 10 1 1 Using INT 17H BIOS Extension to Control the Watchdog Tmer 61 5 10 2 SMI Control citi tinue behitt eege 62 5 10 3 FRAM Memory ACCESS eebe KEREN el ea 62 5 10 4 User LEDS Controlevscscsiitehetdevietivtivticelioelndis et baaielisdivislainvieladivictebieviehadidsiddesselasiaeieiss 63 5 10 5 RS 422 485 Transmitters Control Ports COM3 COMA cceeeeeeteneeeeeeeeteeettteeeeeeeeeeenaaeees 64 5 10 6 Programming of DDMA Controller of IT8888G Drdoe 65 6 BASIC SOMWANG snui usini ccc cececaneuecenedecevecscenssseecetacecusuendecetecseeeedencuenstececeesdannuenseeceseredeseuecseeed 69 6 1 Supplied Ee CEET 69 6 2 Reset CMOS to Factory Defaults from a Remote PDC 69 6 3 BIOS Upgrade suit TE 70 6 4 Manufacturing Link Mode ee ee nn nn nnn enn eee aee eee e ee nnnnaeeeeeeeennnea 73 CPC304 User Manual 2 2011 Fastwel v
72. nk This menu item starts the service mode which allows to explore the disk drives of the CPC304 from a remote PC using a RS232 link between the module and a remote PC see section 5 8 1 CPC304 User Manual 51 2011 Fastwel v 003a E General Software BIOS CPC304 Menu Item Purpose Reset CMOS to last known values This menu command allows you to reset the BIOS configuration parameters to the values with which the system has switched on last time and continue with BIOS Setup Reset CMOS to factory defaults This command allows you to reset the BIOS configuration parameters to the values set by the manufacturer Write to CMOS and Exit This command lets you write the configuration parameters into CMOS memory and exit BIOS Setup Exit without changing CMOS This command allows you to exit the Setup program without writing any possible changes into the CMOS memory thus keeping intact the previously saved configuration Use Up and Down cursor keys or lt Tab gt key to move between menu items lt Enter gt selects the item and allows to proceed with the command or opens the submenu screen 5 3 Basic CMOS configuration On selection of this Main menu item the following screen is shown Figure 5 2 Basic CMOS Configuration Screen Image System BIOS Setup Te CMOS Configurat IDE DRIVE GEOMETRY Master Not installed Slave Not installed Sect Hds Cyls Date gt EFEeb 12 2010 T
73. of Reset CMOS to factory defaults command in Main menu CPC304 User Manual 54 2011 Fastwel v 003a E General Software BIOS CPC304 5 5 Custom Configuration Custom Configuration menu screen is shown on the following figure Figure 5 4 Custom Configuration Menu Screen System BIOS Setup Custom Configuration C 2005 General Software Inc All rights reserved Primary video device Auto PCI INT A Assignment Auto Geode LX graphics z 32 MB PCI INT B Assignment Auto Video device mode Disabled PCI INT C Assignment Auto Video refresh rate EHS PCI INT D Assignment Auto Horizontal sync positive PFO OPTO gt TROF Disabled Vertical sync positive LPT Mode 2 ECP EBB 1 7 Video panel type TET IROQ3 7 COM2 Console Input 2 COMTKBD IROA COMI Console Output COM VGA TIROS SC POT Console MFG Port COML IRQ6 2 EDC IDE UDMA5 Disabled IROJ LPT Legacy USB support Enabled IRQQ ACPI CPU GLIU speed 500 333 MHz IROLO PCL LPT FDC Disabled IROTT z PEL Periodic SMI non maskable IRQ12 PS2 Mouse Periodic SMI Period 7 55 MS IRQ14 ADE COM3 amp COM4 Enabled TROTS COM3 COM4 1 lt CR gt lt Tab gt to select or lt PgUp gt lt PgDn gt to modify lt Esc gt to return to main menu The figure shows the default settings Custom Configuration menu items are described in the table below Table 5 4 Custom Configuration Menu Items Menu Item Options Description Primary video de
74. onnection writing to this register is not recommended Reading is allowed only from state register 8 and from mask register 0Fh but for DDMA the state is read individually for each channel To get the request flag and terminal count flag for all channels it is possible to use the same mask 00010001b The channel mask can be received from the lower bit To write to request registers 9 and to mode registers OBh the register format of 8237 is used but the values in bits 0 and 1 channel number are ignored When writing to the mask register OFh the value should be written to bit 0 not to bit 2 as it is done for 8237 External with respect to 8237 address page registers are used in Legacy DMA for programming of A23 A16 address digits Page addresses are presented in the following page Table 5 8 Legacy DMA Page Register Addresses 87h 83h 8th 82h 8Bh 89h 8Ah 87h CH NI OO oa Ry oO pm In DDMA high address bits registers having offset 2 for each channel correspond to them but these registers have 16 bit width DDMA controller programming virtually does not differ from 8237 programming For a IBM PC legacy DMA controller the following register addresses are defined DMA_COMMAND EQU 008h Command register DMA _ CLEAR EQU 00Dh Clear register Master Clear DMA_REQUEST EQU O009h Request register DMA_MASK EQU OOAh Channe
75. out further notice Software described in this document is provided on an as is basis without warranty Fastwel assumes no liability for consequential or incidental damages originated by the use of this software This document contains information which is property of Fastwel Co Ltd It is not allowed to reproduce it or transmit by any means to translate the document or to convert it to any electronic form in full or in parts without antecedent written approval of Fastwel Co Ltd or one of its officially authorized agents Fastwel and Fastwel logo are trademarks owned by Fastwel Co Ltd Moscow Russian Federation Ethernet is a registered trademark of Xerox Corporation IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers Inc Intel is a trademark of Intel Corporation Geode is trademark of AMD Microsoft is a trademark of the Microsoft corporation In addition this document may include names company logos and trademarks which are registered trademarks and therefore are property of their respective owners Fastwel welcomes suggestions remarks and proposals regarding the form and the content of this Manual CPC304 User Manual 4 2011 Fastwel v 003a E Fastwel LE CPC304 Notation Conventions Warning ESD Sensitive Device This symbol draws your attention to the information related to electro static sensitivity of your product and its components To keep product safety and operabilit
76. quire a Y cable purchased separately To make a custom cable it is recommended to use the JST PHR 6 socket with JST SPH 002T P0 5S contacts for crimping see ACS00031 02 accessory as a counterpart connector The following table shows pinout of CPC304 J7 connector Table 3 12 J7 Contacts Designation 1 KBD CLK 4 GND 2 KBD DATA 5 5V 3 MOUSE CLK 6 MOUSE DATA Mouse and keyboard can be connected via KIB380 interface expansion module with KB and Mouse standard PS 2 connectors J17 and J19 JZ of CPC304 and J18 of KIB380 are connected with the cable supplied with KIB380 interface module see the connections diagram in Chapter 4 CPC304 User Manual 31 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 3 2 11 Audio Port The audio port of CPC304 is realized on the basis of AC 97 compatible audio controller supporting 16 bit sound synthesis industry standard and OPL3 mode emulation External audio devices are connected to the module via two 2 mm pitch JST connectors 5 contact J9 stereo line in line out and 2 contact J8 microphone in For making custom cables it is recommended to use as counterpart connectors JST PHR 5 and PHR 2 sockets for J9 and J8 headers respectively with JST SPH 002T P0O 5S contacts for crimping see ACS00031 01 and ACS00031 03 accessories respectively Table 3 13 Audio J9 and J8 Pinouts J9 J8 1 Lin_In_L 1 Mic_In 2 Lin_In_R 2
77. r rigid object Also be careful not to drop the product since this may cause damage to the heatsink CPU or other sensitive components as well Please keep in mind that any physical damage to this product is not covered under warranty Note This product is guaranteed to operate within the published temperature ranges and relevant conditions However prolonged operation near the maximum temperature is not recommended by Fastwel or by electronic chip manufacturers due to thermal stress related failure mechanisms These mechanisms are common to all silicon devices they can reduce the MTBF of the product by increasing the failure probability Prolonged operation at the lower limits of the temperature ranges has no limitations Caution Electric Shock Before installing this product into a system and before installing other devices on it always ensure that your mains power is switched off Always disconnect external power supply cables during all handling and maintenance operations with this module to avoid serious danger of electrical shock CPC304 User Manual 6 2011 Fastwel v 003a E Fastwel LE CPC304 Unpacking Inspection and Handling Please read the manual carefully before unpacking the module or mounting the device into your system Keep in mind the following ESD Sensitive Device A Electronic modules and their components are sensitive to static electricity Even a non perceptible by human being static dis
78. rate setting in characters per second 2 30 or disabled Typematic Delay Sets typematic delay of the keyboard in seconds 0 25 0 5 0 7 1 0 IDE DRIVE GEOMETRY Master Slave IDE disk drive geometry selection for Primary Master Master and Primary Slave Slave Options Not installed disk drive not connected default setting Autoconfig Normal automatic geometry detection without disk parameters translation Autoconfig LBA automatic geometry detection with translation of disk parameters into linear address Autoconfig Large disk parameters translation using Phoenix algorithm User Type user enters custom parameters in Sect Hds and Cyls fields CDROM CDROM drive installed USB Hard Drive s Enables use of USB disks options 1 Drive 2 Drives Disabled default Onboard Flash Disk Enables or disables the onboard flash disk 1 GB enabled by default 1 Disk Disk C Selection of a disk drive to assign C Options IDE Master default IDE Slave Floppy Disk Drive FDD Floppy 0 type selection Options Not Installed FDD is not connected default 360 KB 5 25 1 2 MB 5 25 720 KB 3 5 1 44 MB 3 5 2 88 MB 3 5 Memory Base Ext Indication of Base and Extended memory size available for applications CPC304 User Manual 53 2011 Fastwel v 003a E General Software BIOS rasTwel CPC304 5
79. rter TX 120 J10 J12 3 4 off RS422 485 transmitters are controlled via GPIO5 COM3 and GPIO6 COM4 lines of CS5536 GPIO port Setting these lines to logical 1 or 0 switches the tranmitters on or off respectively GPIO lines programming samples can be found in subsection 5 9 5 of this Manual Custom cables can be used to connect external devices to RS422 485 interfaces The recommended counterpart connectors for J11 and J13 headers of CPC304 are JST PHR 5 with JST SPH 002T P0O 5S contacts for crimping or ACS00031 accessory The following table shows contacts designation for J11 and J13 connectors CPC304 User Manual 30 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 Table 3 11 J11 and J13 Contact Assignments 1 TX 2 TX 3 RX 4 RX 5 GND External devices can be connected to RS422 485 interfaces using KIB380 interface expansion module The devices are connected to 1 RS 485 J11 and 2 RS 485 J14 WAGO terminal blocks of KIB380 The supplied with KIB380 interface cables are used to connect COM J11 and COM4 J13 headers of CPC304 to J10 and J13 connectors of KIB380 respectively The connections diagram in Chapter 4 illustrates the wiring layout 3 2 10 PS 2 Keyboard and Mouse Interface PS 2 keyboard and mouse interface is routed to J7 6 pin 2 mm pitch JST header Simultaneous connection of these two devices to J7 connector of CPC304 re
80. ry C0000h C7FFFh 32 KB Display BIOS memory or external bus memory C8000h DFFFFh 96 KB External bus memory E0000h FFFFFh 128 KB System BIOS area 100000h XXXXXXXh Extended system memory XXXXXXXh FFFFFFFh 255 MB Higher addresses are allocated for use as video memory Its size is set in BIOS Setup Custom Configuration menu FFFFFFFh 10007FFFFh 512 KB BIOS ROM CPC304 User Manual 42 2011 Fastwel v 003a E Fastwel Lee CPC304 User Manual 43 Functional Description CPC304 3 3 2 UO Addressing Table 3 27 UO Address Space 0000h 001Fh DMA1 0020h 0021h PIC Master 0022h 0023h LX Configuration 0028h 002Fh Local Bus 0040h 005Fh Timer 0060h OO6Fh POST Keyboard Shadow registers 0070h 007Fh CMOS NMI Mask control registers 0080h 009Fh DMA Page registers OOA0h 00BFh PIC Slave 00COh OODFh DMA2 OOFOh OOFFh Numeric coprocessor 0100h 016Fh External ISA bus External bus access 0170h 0177h Reserved No access 0180h 01BFh External ISA bus External bus access 01C0h 01DFh External ISA bus or not available This range is not available when COM3 and COM4 are disabled in BIOS Setup 01E0h 01EFh Reserved No access 01FOh 01F7h Primary IDE 020
81. s They allow stacking up to four PC 104 modules or up to three PC 104 Plus expansion modules Both connectors are available as a socket at the top side of the module and as a pin array at the bottom side of CPC304 Attention A CPC304 does not support PC 104 ISA external graphics controllers Only PC 104 Plus PCI graphics controllers are supported 3 2 23 1 ISA Header P J1 header mounted on CPC304 allows connection of PC 104 expansion modules via 16 bit ISA bus The processor module can accommodate four PC 104 expansion modules maximum The contact configuration of P J1 header is shown in the figure below The tables following the figure give the designation of its contacts Figure 3 13 ISA Header Contacts Layout Bi Iaseeeaeess Sa Seel B32 Al See EI HEB A32 Do E io Table 3 22 ISA P J1 Connector Rows A and B Contacts Designation Al IOCHK B1 GND Power A2 SD7 In Out B2 RESET Out A3 SD6 In Out B3 5V Power A4 SD5 In Out B4 IRQ9 In A5 SD4 In Out B5 5V Power A6 SD3 In Out B6 DRQ2 In A7 SD2 In Out B7 12V Power A8 SD1 In Out B8 OWS In AQ SDO In Out B9 12V Power A10 IOCHRDY In B10 GND Power A11 AEN Out B11 SMEMW Out A12 SA19 Out B12 SMEMR Out A13 SA18 Out B13 JO Out A14 SA17 Out B1
82. s recovery from CL BX DMA 2 channel buffer address register Put lower address bits to AL Set lower address byte Delay for bus recovery Put 8 15 address bits to AL Set middle address byte Delay for bus recovery Put 16 23 address bits to AL Channel 2 page register address Set higher address byte FDD Channel mask register Reset mask command for DMA 2 channel Enable DMA request ODELAY is a macro providing pause for bus recovery by slow 8237 controller This code with minimal changes can be used for programming DDMA For example channel DDMAS3 It is necessary to replace the registers addresses of Legacy DMA by the default addresses of DDMAS channel C DMA_COMMAND E DMA_CLEAR E DMA_REQUEST E DMA_MASK E MA_MODE MA_FF MA_MULTIMASK I GI G 02308h Command register 0230Dh Clear register Master Clear 02309h Request register 0230Ah Channel mask register not used 0230Bh Mode register 0230Ch High low switch register 0230Fh Mask register for all channels Multimask The data registers addresses are changed compared to Legacy DMA and page registers are linked to the registers of DDMA channel CPC304 User Manual 67 2011 Fastwel v 003a E General Software BIOS Fastwel LBs CPC304 DMA3ADR EQU 02300h DMA 3 channel current address register DMA3CNT EQU 02304h DMA 3 channel counter register DMAPG2
83. tic material will VOID all warranties Then package the product in a safe container for shipping 4 The customer pays for shipping the product to Fastwel or to an official Fastwel representative or dealer CPC304 User Manual 8 2011 Fastwel v 003a E Introduction Fastwel EN CPC304 1 Introduction This document presents general information on CPC304 processor module the details of its proper and safe installation configuration and operation The issues of PC 104 modules and external devices connection are also considered 1 1 Module Introduction CPC304 is a PC 104 Plus single board computer for embedded applications It is designed for use in mission critical on board systems requiring low power consumption and wide operating temperature range CPC304 is based on AMD Geode LX800 CPU and AMD CS5536 I O companion CPC304 provides full support for PC 104 and PC 104 Plus expansion modules and data exchange via both 16 bit ISA and 32 bit PCI buses All key components including CPU chipset memory and periphery controllers are soldered on board providing excellent vibration stability and increased efficiency of protective conformal coating CPC304 offers wide variety of data display capabilities It allows simultaneous operation of standard VGA interface 24 bit LVDS interface and 18 bit interface for TFT or DSTN LCD panels connection Data storage subsystem is based on single channel IDE controller that is able to drive two IDE
84. tive components Please follow the ESD safety instructions to ensure module s operability and reliability E Use grounding equipment if working at an anti static workbench Otherwise discharge yourself and the tools in use before touching the sensitive equipment Try to avoid touching contacts leads and components Extra caution should be taken in cold and dry weather CPC304 User Manual 46 2011 Fastwel v 003a E External Connections Fastwel Lee CPC304 4 2 Connection of Peripheral Devices External devices are connected to CPC304 directly or via KIB380 interface expansion module Figure 4 1 External Devices Connection VGA Remote PC Monitor PS 2 Keyboard Discrete UO External LEDs PC 104 Plus 32 bit PCI CompactFlash Type I II Card 3 5 HDD or 0 CD ROM Drive CPC304 User Manual 47 2011 Fastwel v 003a E External Connections Fastwel Een CPC304 The following devices are necessary to put the module into operation Si PC 104 power supply connected through P J1 and U49 headers or an external power supply unit with 5 V and not less than 3 A output connected to J24 power connector If the module is intended for operation with PC 104 modules requiring 12 V then this voltage should be supplied to the appropriate J24 contact For checkout and adjustment purposes the AT or ATX power supply units are re
85. ultaneous operation support FPU of the processor supports MMX and AMD 3DNow technology instruction sets The CPU is complemented with AMD Geode CS5536 companion device providing support for numerous I O functions including IDE USB AC 97 compatible audio and power management interfaces 3 2 2 SDRAM Memory Four DDR 333 SDRAM memory chips are soldered on the bottom side of the PCB Total memory size is 256 MB 3 2 3 Reserved Flash BIOS The CPC304 takes advantage of flash memory based BIOS Two Flash BIOS chips storage Capacity is 512 KB each The main working copy of BIOS occupies 512 KB on a chip in 32 contact PLCC32 panel Reserve BIOS copy is stored on a soldered chip and is used for emergency boot Switching between the main and reserve BIOS copies is performed automatically It is possible to upgrade main and reserve copies of BIOS in system The procedure is described in section 6 3 CPC304 User Manual 19 2011 Fastwel v 003a E Fastwel Ley CPC304 Functional Description 3 2 4 IDE Interface One channel IDE controller allows connection of up to two IDE devices master and slave and conforms to ATA 6 specification Since soldered NAND flash disk uses IDE interface along with external devices such as CompactFlash card in a socket or disk drives connected to J19 connector there is a limited number of the devices connection variants Table 3 1 IDE Channel Devices Connection Variants
86. uration gt Console MFG Port VGA Output to video controller COM VGA Output to COM and video controller default Transmission parameters 115200 n 8 1 Console MFG Port COM1 Serial port number selection for operation in the console or COM2 Manufacturing Link modes COM1 is the default port IDE UDMA5 Enabled UDMAS5 mode support disabled by default Disabled Legacy USB support Enabled Legacy USB devices support enabled by default Disabled support for USB keyboards and mice Auto CPU GLIU speed 300 266 CPU system memory clock speed in MHz 500 333 MHz default 333 333 400 266 400 333 500 333 LPT FDC LPT J23 connector operation mode LPT parallel port FDC for FDC connection of a floppy disk drive When Disabled is selected Disabled default the assigned interrupt lines can be used by other devices Periodic SMIs Non maskable Periodic SMI requests type Non maskable by default Maskable Periodic SMI Interval 55 110 220 Periodic SMI requests interval in ms 55 ms by default COM3 A COM4 Enabled COM3 and COM4 serial ports control Enabled default setting Disabled For BIOS version 1 2 it is necessary to disable COM3 and COM4 ports when using the operating systems with ACPI support Windows Linux PCI INT A Assignment Auto Interrupt assignment for PCI devices using INT A INT B INT C PCI INT B Assignment IRQ5 and INT D lines Automatic interrupt assignment default IRQ5 P
87. ure below presents the Shadow Configuration menu screen Figure 5 6 Shadow Configuration Menu Screen Image System BIOS Setup Shadow Cache Configuration C 2003 General Software Inc All rights reserved Shadowing Chipset Shadow Enabled Shadow 16KB Enabled Shadow Disabled Shadow 16KB Disabled Shadow Disabled Shadow 16KB Disabled Shadow Disabled Shadow 16KB Disabled Shadow Enabled Shadow 16KB Enabled Shadow Enabled Shadow 16KB Enabled Shadow Enabled 1 lt CR gt lt Tab gt to select or lt PgUp gt lt PgDn gt to modify lt Esc gt to return to main menu The figure shows the default settings The Shadowing parameter can be either Chipset or None All other items allow to choose between the two options Enabled or Disabled Use arrow keys lt Tab gt key and lt Enter gt to move between items and for selection lt PgUp gt lt PgDn gt lt gt or lt gt are used to change the selected parameter lt Esc gt to return to the Main Menu If Enabled is selected Shadow Configuration menu items allow to copy BlOSes of extension modules into operating memory by 16 KB blocks on initialization of the processor module 5 9 The Rest Main Menu Commands 5 9 1 Start RS232 Manufacturing Link Manufacturing Link mode allows to modify the flash based BIOS of the CPC304 module with fwflash exe or fwflash_win exe utility or to exchange files between the module and a
88. utdown time of the system in which the battery is installed operated for a long time Important A Replacing the battery make sure the polarity is correct Note XK It is recommended to replace the battery after approximately 4 years to be sure it is operational It is recommended to disconnect the battery if the module is not Dispose of used batteries according to the local regulations 4 3 Software Installation The installation of the peripheral drivers is described in the accompanying information files For details on installation of an operating system please refer to the relevant software documentation CPC304 User Manual 49 2011 Fastwel v 003a E General Software BIOS gt 7 CPC304 5 General Software BIOS The General Software BIOS in CPC304 is an adapted version of a standard BIOS for IBM PC AT compatible personal computers equipped with x86 compatible processors BIOS provides low level support for the central processing memory and I O system units System settings can be changed using the BIOS Setup program 5 1 BIOS Setup Program Introduction With the BIOS Setup program you can modify BIOS settings and control special features of the module The Setup program offers a convenient menu interface to modify basic system configuration settings and switching between the subsystems operation modes These settings are stored in a dedicated battery backed memory CMOS RAM that keeps the information while th
89. vice Auto In absence of an external graphics controller the internal one is selected LX Graphics Internal graphics controller enabled PCI VGA Card External PCI graphics enabled None No graphics controller enabled graphics memory is released for use by system Geode LX Graphics 4 60 System memory size intended for use by CPU graphics core MB Disabled 32 MB is the default setting CPU graphics subsystem is switched off 0 MB used Video device mode Disabled LCD panel is not used default 320x240 Resolution of the LCD panel in use 640x480 800x600 1024x768 Video refresh rate 60 70 75 85 LCD panel video refresh rate Hz 100 Horizontal sync Positive Horizontal synchronization polarity positive by default Negative CPC304 User Manual 55 2011 Fastwel v 003a E General Software BIOS Fastwel Lee 440 880 1760 Vertical sync Positive Vertical synchronization polarity positive by default Negative Video panel type TFT LVDS LCD panel interface Console Input Console input INT 16h BIOS options COM Input via COM port the number of COM port is selected in Custom Configuration gt Console MFG Port KBD Input via keyboard port COM KBD Input via keyboard port and COM port default Terminal settings should be 115200 n 8 1 Console Output Console output INT 10h BIOS options COM Output to COM the number of COM port is selected in Custom Config
90. y Configuration C 2005 General Software Inc All rights reserved Enable PnP Support gt Enabled Enable PnP 0 5 Enabled Assign TROO to PnP Disabled Assign IRQ8 to PnP Disabled Assign LROU vo Pre Enabled Assign IROJ to PnP Disabled Assign IRQ2 to PnP Enabled Assign TROTO to Pne Disabled Assign IRQ3 to PnP Enabled Assign TROLL to PnP Enabled Assign IRQ4 to PnP Disabled Assign IRQ12 to PnP Enabled Assign IROS to PnP Enabled Assign TROLS to PNE Enabled Assign IROG to PnP Disabled Assign IRQ14 to PnP Enabled Assign IRQ7 to PnP Disabled Assign IRQ15 to PnP Enabled Assign DMAO to PnP Disabled Assign DMA4 to PnP Enabled Assign DMA1 to PnP Disabled Assign DMA5 to PnP Enabled Assign DMA2 to PnP Disabled Assign DMA6 to PnP Disabled Assign DMA3 to PnP Enabled Assign DMA7 to PnP Enabled t i gt lt CR gt lt Tab gt to select or lt PgUp gt lt PgDn gt to modify lt Esc gt to return to main menu EE The figure shows the default settings All items allow to choose between the two options Enabled or Disabled Use arrow keys lt Tab gt key and lt Enter gt to move between items and for selection lt PgUp gt lt PgDn gt lt gt or lt gt are used to change the selected parameter lt Esc gt to return to the Main Menu CPC304 User Manual 58 2011 Fastwel v 003a E General Software BIOS Fastwel LBs CPC304 5 8 Shadow Configuration The fig
91. y it is necessary to handle it with care and follow the ESD safety directions Warning This sign marks warnings about hot surfaces The surface of the heatsink and some components can get very hot during operation Take due care when handling avoid touching hot surfaces Caution Electric Shock This symbol warns about danger of electrical shock gt 60 V when touching products or parts of them Failure to observe the indicated precautions and directions may expose your life to danger and may lead to damage to your product Warning Information marked by this symbol is essential for human and equipment safety Read this information attentively be watchful Note This symbol and title marks important information to be read attentively for your own benefit SE gt b gt CPC304 User Manual 5 2011 Fastwel v 003a E Fastwel Ley CPC304 General Safety Precautions This product was developed for fault free operation Its design provides conformance to all related safety requirements However the life of this product can be seriously shortened by improper handling and incorrect operation That is why it is necessary to follow general safety and operational instructions below A A amp Warning All operations on this device must be carried out by sufficiently skilled personnel only Warning When handling this product special care must be taken not to hit the heatsink if installed against anothe
92. y setting 1 2 Compact Flash Slave Nand Flash Master Note A For generations of the module below 1 3 In case the NAND flash chip is not used Onboard NAND Flash option in BIOS setup is set to Disable the jumper at J26 pinpad should be removed or set to the position 3 4 Note In case the NAND flash chip is not used Onboard Flash Disk option in BIOS setup is set to Disable it is possible that some CompactFlash cards will operate only in one mode Master or Slave For correct operation it is necessary to set the required configuration using J26 jumper switch and settings in Basic CMOS Configuration section of BIOS Setup 3 2 17 J28 Pinpad J28 pinpad is used to switch between the discrete input J27 operation modes Reset input or IRQ input Pins 4 6 allow to enable IRQ on PFO Closed 1 3 and 4 6 factory setting Table 3 16 J28 Jumpers Positions 1 3 closed Reset input enabled 3 5 and 2 4 closed IRQ input enabled 4 6 closed IRQ on PFO enabled IRQ is set in BIOS Setup see Custom Configuration section CPC304 User Manual 34 2011 Fastwel v 003a E Functional Description Fastwel Een CPC304 3 2 18 Discrete Input Output CPC304 offers 8 programmable input output channels routed to J5 one row connector AMP PLSx9 2 5 mm pitch on the top side of the module Discrete input output lines are connected to Super IO W83627HG GPIO lines via protective current li

Download Pdf Manuals